Loading...
HomeMy WebLinkAbout20190913 Franco Residence Application IFOR OFFICE USE' art OF SARATOGA SP' li, GS -- - 4, DESIGN REVIEW COMM15510 f 21 IT -'.., eE (Application#) City Hall-474 Broadway SE I 1 7 * Saratoga Springs, New York I ;. , 3 2019 I Tel:5 I B-587-3550 x.515 fax:518- tip-9480 (Date received) www.saratoga-springs.o : 114"Y ARCHITECTURAL/ HISTORIC REVIEW APPLICATIO APPLI CANT(s)* OWNER(S) (11 not applicant) ATTORNEY/AGENT James J. Franco J2 Design & Build Name 171 Church Street 7 Wells Street Suite 104 Address___ Saratoga Springs, NY 12866 Saratoga Springs, NY 12866 Phone 518466-2891 i _ / 518-306-5234 Email .1franco©nycap.rr.com info@j2designercorn Identify primary contact person: lit Applicant 0 Owner 0 Attorney/Agent *An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant's interest in premises: a Owner 0 Lessee 0 Under option to lease or purchase PROPERTY INFORMATION 171 Church Street 165.50 1 59 Property Address/Location: Tax Parcel #: (for example: 165.52-4-37) Current Zoning District: UR-3 Property use: NI Residential 0 Non-residential/mixed-use Type of Review: II Architectural 0 Historic 0 Extension/modification (of current approval) Summary description of proposed action: Q I"\,Z-- -"c-z) ' Q4\ ) — V_ C).L i OcA 110(..:'47(-1/ Has a previous application been filed with the DRC for this property? IN No 0 Yes—date(s)? -App. No.(s)? Revised 01/2019 APPLICATION FEE (payable to "Commissioner of Finance"): Residential Structures (principal, accessory) $50 Non-residential mixed-use structures (principal) $500 Residential approval—extension/mod $50 Non-residential signs, awnings, accessory structures $125 Non-residential mixed-use sketch $150 Non-residential approval—extension/mod $125 Demolition $350 **A "complete" application consists of j, hard copy(origiiaalLind I electronic copy of application &XL other materials as required below: New Construction Additions o Color photographs showing site/exterior details of existing structures and adjacent properties o Site plan,drawn to scale,showing existing&proposed construction, property lines&dimensions, required&proposed setbacks&lot coverage,site features (fences,walks,trees, etc.);on no larger than 2'x3'sheet—smaller preferred if legible o Elevation drawings showing design of all sides of existing&proposed construction—label dimensions,colors, materials, lighting(fixture &lamp type,wattage),etc.-include compass bearing&scale;no larger than TA'sheet—smaller permitted if legible o Floor plans for proposed structure;on sheet no larger than 2'x3'—smaller permitted if legible DI Product literature,specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color(in non-residential districts only) 111 Color photographs showing site/exterior details of existing structures and that illustrate affected features ill Elevation drawings showing all sides of existing&proposed construction—label dimensions,colors, materials, lighting(fixture&lamp type,wattage),etc.-include compass bearing&scale; no larger than 2'x3'sheet—smaller permitted if legible i Product literature,specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts only (Front setbacks:UR-I &INST-1-11-R=30';UR-4=25';UR-2,UR-3&NCUD-1=10') - Installation, removal or change in material of drive-and walkways - Installation or removal of architectural, sculptural or vegetative screening over 3' in height - Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2' diameter) For any of above: O Color photographs showing site/exterior details of existing structures,and of adjacent properties O Site plan showing existing&proposed construction:include property lines&dimensions, required &proposed setbacks&lot coverage,site features(fences,walks,trees,etc.) street names,compass bearing&scale;no larger than 2'x3'sheet—smaller preferred if legible o Product literature,specifications and samples of proposed materials and colors Signavnings CI Color photographs showing site/exterior details of existing structures,and adjacent properties E l Plan showing location of proposed sign/awning structure on building/premises: no larger than I I"x17" E l Scaled illustration of proposed sign/awning structure and lettering(front view&profile):include ail dimensions of structure;type, dimensions and style of lettering or logo;description of colors, materials, mounting method and hardware El Descriptions,specifications of proposed lighting including fixture&lamp type,wattage, mounting method,and location o Product literature, specifications and samples of proposed materials and colors Demolition o Color photographs showing site/exterior details of existing structures,and of adjacent properties o Site plan showing existing and any proposed structures-include dimensions,setbacks,street names,compass bearing,and scale 0 Written description of reasons for demolition and, in addition: o For structures of"architectural/historical significance",demonstrate"good cause"why structure cannot be preserved El For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a "contributing"structure in a National Register district(contact City staff), provide plans for site development following demolition- include a timetable and letter of credit for project completion Telecommunication facilities O Color photographs showing site/existing structures,and of adjacent properties El Site plan showing existing and proposed structures: include dimensions,setbacks,street names,compass bearing,and scale CI Scaled illustration of proposed structures: include all dimensions;colors, materials, lighting, mounting details o Consult Article 240-12.22 of the City's Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 01/2019 Request for extension ofcurrent approval 0 Identify date of original DRC approval: Current expiration date: Org.App. No. Q Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SER Environmental Assessment Form 0 Applicants proposing the following must complete"Part I"of the SEAR Short Environmental Assessment Form(available here: http;//www.dec.ny.govidocs/permitsei operations /s afpart ne pdf): -Construction or expansion of a multi-family residential structure(4 units +) -Construction or expansion(exceeding 4,000 sq.ft.gross floor area)of a principal or accessory non-residential structure -Telecommunications facility, radio antennae,satellite dishes -Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809)in this application? N No 0 Yes If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification I/rare,the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Commission. By the signature(s)attached hereto, I we certify that the information provided within this application and accompanying documentation is,to the best of my/our knowledge,true and accurate, l/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. l/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, i/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review of the Zo ing Co of the City of S oga Springs. Date:' -i 3J2d9 plicant signature) Date: (applicant signature) If applicant is not the currently the owner of the property,the current owner must also sign. Owner Signature: Date: Owner Signature: Date:. Revised 01/2019 FOR OFFICE USE ONLY This application has been reviewed by the Zoning Enforcement Officer and is being forwarded to the Commission. Signature: Date: Additional Comments: Revised 01/2019 , ,--__- ., ------- ...Existing Roof System To RPROPOSED PORCH REPAIR-171 CHURCH STREET emain -------- - — . ..• Temporary 2x Supports To Be Replaced .—..-- ..-----'l i i 1=- i--*--11--1 I ____.• - W__1 ..--- - _....__..pRoeriracce!jiiing To Be Existing Porch Floor To Be Replaced • i i_ (i _ I 't .C•1, ':,-_,;:L,t..,1 N, ,,;-,,:::,;,.. ' —.— '1' .• -It,: .,,-,,,,,_;,;,?-.. .,. „_ ._ .•..,..„,....„ .__ _ .1.... ,,,,,,..q.. 14 ; ,.L Llii.:--'74!'- 7-=_ - '-- • EXISTINGx?sr't:rPIO?ro'ih!s-loti r'Ri?peLdjRCH ST ` • •,,, "t-.1...'"=6:7 1—'7'7—.• --'.511! , „..______,Tii ___•4_.__ __„:_...2- _ - --- _7. , -----, 411 ,„,,,,,A.i.i,1;,:4,4-,•-,,A,,-, 1 Showing Existing Porches To Be Repaired EXISTING CONDITIONS-REAR No Change 'dlr.' i 1,4-,,,• . ,, ,L- ., I Replaced Church St&Van Dorn Facades ii- . lip _ •INIE- . - ;-,-,_ ' g ii .. • •-,' . , :... •., •,......„. S1qn x'Tiii3g 1-I'lo(icl -T,IT:'RTpRa iie'di U RCH'VAN D°RN ST " , ------- EXISTING CONDITIONS-WEST SIDE ELEVATION ' I B AGI No Change ..,, . i 107 1 11111 ,011 iiiiig t ., . Ns , 7,7____. ro,‘," ........ ,, . ...„ o 1,", :,„ , „.,,,•,,t,_ . .:, ,i,„d . .77 _ , ....._ ..,...„.....:...„.„,..: Proposed 36"Endurance Vinyl Railing-Turned Colonial-by RDI Proposed 5"x5"Structural POSta by RDI(TUrned) P°.Detail. .' .."''I., ''',5S.-,11?;',.1: a Proposed Lattice Skirting Detail 0 1 PROPOSED FOOTING/FRAMING DETAIL j2Zt= 36"Endurance Vinyl Railings(Colonial) To Code. New 5"x 65 Porch Posts CONSTRUCTION OVERVIEW . . rast:VdTWITrtntyeltigfroaPlorch Ceiling) _Ill (3)2"x 8"PT Beam w/1x Trim I I i __,__ New 5"x 5"Structural Posts • 6"x 6,".1.xT4P.,oFsrtawm/eS iwrni tphs oi_ant tB,cr ea c(ktyept s) •---________46. Hand Rails to Code =gng)Grade(No 1.1"..............-.111,.... '.....MMEMII.I......IMIMM.I ill IIII I . Existing Concrete Stairs to Remain New Porch Framing(see detail) , ,' '-:,.... ,. •_ ii.......,.,111.t.A.M.......... 11H1 4 1111MR1 IIIIIIII 1111111111H 1 60"Precast Concrete Footing (Minimum 48"Cover) Pliiillilift '` I_LICIE "."...1' ILL.....111. 1"x4"Frame w/Lattice Insert —.IIIIIIIIIIIII rs't sP Maontli in g s (See Detail) PROJECT SCOPE: OVERVIEW:Repair/replace porch components on existing home. 0 7:1 JO MAIN PORCH: i.2,,2 1. Remove existing porch floor and framing PROPOSED FRAMING DETAIL-PLAN VIEW 2. Retain and level existing porch roof(s). ,E1M-1 3. Install seven(7)12"concrete footings in locations as shown. ''1'-r-T-'17-7-i--c 7T7'11-11"--;.1 4. 6 x 6 PT Posts with Simpson Post Base to carry roof load to concrete. , IIIIII 2 New 12"Pre-Cast Concrete Footing I l III 11 Eis,ii,n11,,illrcil,i,ilei 1,,,,g1114 d New 2@ 2"x 8"PT Beam 5. (3)2''x 8"PT Beam&(1)2''x 8"PT Ledger per plans. i' ILLH IVL/--iii i ___-I.,,,,_,,,,,,,_„,-,New 12"Pre-Cast Concrete Footing 6. 2 x 8 pt deck framing with Simpson ZMax hangers per drawing. Existing Enclosed Porch ,---- •6"x 6"PT Post w/Simpson Post Base 7. New 1"PT decking. ,---HI •3@ 2"x 8"PT Beam g cci',1 8. 5"x5"Structural Columns(Turned)Per Details. 7-7-7_,___„__-E.II .12;x LiPs-trs Ve?degreLralaeds.24"°'t° 0:a; 9. Provide lx Trim and Lattice Detail Per Plans. A ----278"PT Joist w/ZMax hangers 16"o.c. 10.Retain and Level Existing Precast Entry Steps-Add Hand Rails to Code i-= {i, 1X PT Decking Existing Home @ 171 Church Street i _il 5"ox 5;Structural Posts(5000 lb)to Carry Roof 11.36"Endurance Vinyl Porch Railings(White Turned Colonial)to Code ,,, 12.Finish Porch Ceiling with Vinyl Soffit Materials(Non-Vented) , ' •36"Endurance Vynil Hand Rails to Code. , , -II , A SIDE PORCH: pE N ,R 1. Jack and level existing porch. .."19 I I 2. Install Two(2)12"concrete footings in locations as shown. 3. 6 x 6 PT Posts with Simpson Post Base to carry roof load to concrete. a 4. (3)2"x 8"PT Beam to Carry Floor Loads. 5. Simpson Hangers as Required. 01