HomeMy WebLinkAbout20250024 191 Caroline Mini Split NOD Tamie Ehinger, Chair CITY OF SARATOGA SPRINGS Rob DuBoff, Vice Chair i 4 \ A Chris Bennett DESIGN REVIEW BOARD Leslie DiCarlo Jeff Gritsavage a City Hall - 474 Broadway Tad Roemer r .4r�L Saratoga Springs, New York 12866 Geoff Wood Tel: 518-587-3550 x.251 7 Karen Cavotta,Alternate Kennedy Flack,Alternate NOTICE OF DECISION In the matter of the application #20250024 191 Caroline St. Mini Split 191 Caroline St., Saratoga Springs, New York 12866 involving Historic review of exterior equipment installation within the Urban Residential -3 (UR-3) District., tax parcel #166.53-2-46, within the City of Saratoga Springs. In accordance with 6 NYCRR Part 617, the Design Review Commission classifies this request as a SEAR: 0 Type II action — exempt from further SEAR review And, in accordance with the objectives, standards and guidelines contained in the Unified Development Ordinance, the Design Review Board issues the following decision on January 29, 2025: 0 Approve the application as submitted or shown on the attached plans Record of vote: motion to approve made by T Ehinger, seconded by C Bennett : passed 7-0 In favor: TEhinger, CBennett, LDiCarlo, RDuBoff, JGritsavage, TRoemer, G Wood As a result of this decision, the applicant: 0 may proceed with the proposed project as approved Please contact the Building Department to verify permit requirements. i / January 31 , 2025 Chair Received by Accounts cc: Building Department Accounts Dept. Applicant/Agent Page 1 of 1 Site pictures James Sautter 191 Caroline St, Saratoga Springs, NY 12866 Picture 1 : Outdoor unit will be place outside back yard right side when facing the street. Picture 2: Line set run will go through the crawl space to hide it from outside 7 , Picture 3: Line set from basement will come out from left front side and will have line set cover and enter into house. Picture also shows where indoor wall unit will mount. A Picture 4: Outdoor distance from house. v , a 'ta Picture 5: Pictures shows approx placement will be in between the two wooden poles. This is facing the street view. V % R w i r MSZ-GS18NA& MUZ-GS18NAHZ M'ITSUIS 18,000 BTUIH WALL-MOUNTED INDOOR UNIT /_ELECT 1R nnn PT IN WVPFP WPAT P MP 011T1[1(1PI INIT " ""° °". Maximum Capacity BTU/H 22,000 Rated Capacity BTU/H 18,000 Minimum Capacity BTU/H 5,800 Cooling at 95°F' Maximum Power Input W 2,150 Rated Power Input W 1,340 Moisture Removal Pints/h 3.8 Sensible Heat Factor 0.77 Power Factor[208V/230V] % 98.0/98.0 Maximum Capacity BTU/H 25,000 Rated Capacity BTU/H 19,000 Heating at 47°F' Minimum Capacity BTU/H 6,600 Maximum Power Input W 4,000 Rated Power Input W 1,340 Power Factor[208V/230V] % 98.0/98.0 Maximum Capacity BTU/H 22,400 Heating at 17°F' Rated Capacity BTU/H 11,700 - - Maximum Power Input W 3,570 Rated Power Input W 1,230 Heating at 5°F4 Maximum Capacity BTU/H .... 19,000 Maximum Power Input W 3,520 Heating at-5°Fs Maximum Capacity BTU/H 16,460 Heating at-13°F7 Maximum Capacity BTU/H 13,930 SEER2 21.5 EER2' 13.45 HSPF2[IV] 9.6 COP at 47°F' 4.16 Efficiency COP at 17°F at Maximum Capacity' 1.84 COP at 5°F at Maximum Capacity4 1.58 COP at-5°F at Maximum Capacity6 1.42 COP at-13°F at Maximum Capacity' 1.25 ENERGY STAR®Certified Yes Voltage,Phase,Frequency 208/230,1,60 Guaranteed Voltage Range VAC 187-253 Voltage:Indoor-Outdoor,S1-S2 VAC 208/230 Electrical Voltage:Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating[SCCR] kA 5 Recommended Fuse/Breaker Size(Outdoor) A 20 Recommended Wire Size[Indoor-Outdoor] AWG 14 Power Supply Indoor unit is powered by the outdoor unit MCA A 1.0 Fan Motor Full Load Amperage A 0.74 Fan Motor Output W 40 Airflow Rate at Cooling,Dry CFM 250-325-407-511-629 Airflow Rate at Cooling,Wet CFM 225-292-367-460-566 Airflow Rate at Heating,Dry CFM 287-375-459-550-629 Sound Pressure Level[Cooling] dB[A] 28-33-38-44-49 Indoor Unit Sound Pressure Level[Heating] dB[A] 28-34-39-43-48 Drain Pipe Size In.[mm] 5/8[15.88] Coating on Heat Exchanger Dual Barrier Coating External Finish Color Munsell 1.OY 9.2/0.2 Unit Dimensions W x D x H:In.[mm] 36-5/16 x 9-13/16 x 12[923 x 250 x 305] Package Dimensions W x D x H:In.[mm] 39 x 13 x 15[990 x 330 x 380] Unit Weight Lbs.[kg] 28[12.4] Package Weight Lbs.[kg] 32[14.2] Indoor Unit Operating Temperature Cooling Intake Air Temp[Maximum/Minimum]' °F 90 DB,73 WB/67 DB,57 WB Range Heating Intake Air Temp[Maximum/Minimum] °F 80 DB/70 DB NOTES: AHRI Rated Conditions 'Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB (Rated data is determined at a fixed compressor speed) 'Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB 'Heating at 17°F(Indoor H Outdoor) °F 70 DB,60 WB//17 DB,15 WB Conditions 4Heating at 5°F(Indoor//Outdoor) °F 70 DB,60 WB//5 DB,4 WB 'Indoor/Outdoor Unit Operating Temperature Range(Cooling Air Temp[Maximum/Minimum]): MCA A 18.0 Fan Motor Full Load Amperage A 0.93 _ Airflow Rate[Cooling/Heating] CFM 1800/1646 Refrigerant Control LEV Defrost Method Reverse Cycle Coating on Heat Exchanger Blue Fin Coating Sound Pressure Level,Cooling' dB(A) 54 Sound Pressure Level,Heating dB(A) 55 Compressor Type DC inverter driven Twin Rotary Outdoor Unit Compressor Model SNB172FQKMT Compressor Rated Load Amps A 13.6 Compressor Locked Rotor Amps A 17.0 ........................... ........... ....... ................. ................. ................. ...................... ............ Compressor Oil[Type//Charge] oz. FV50S//11.8 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Built-in Unit Dimensions W x D x H:In.[mm] 33-1/16 x 13 x 34-5/8[840 x 330 x 8801 Package Dimensions W x D x H:In.[mm) 38-3/4 x 16-3/4 x 39(980 x 420 x 990] Unit Weight Lbs.[kg] 118[53] _ Package Weight Lbs.[kg] 136[62] _ Cooling Air Temp[Maximum/Minimum]" °F 115 DB/14 DB Outdoor Unit Operating Temperature Cooling Thermal Lock-out/Re-start Temperatures" °F -4/0 Range Heating Air Temp[Maximum/Minimum] °F 75 DB,65 WB/-13 DB,-14 WB Heating Thermal Lock-out/Re-start Temperatures" °F -22/-14 Type R410A Refrigerant Pre-Charged Refrigerant Amount Lbs,oz 3.0,7.0 Maximum Pre-Charged Piping Length Ft.[m] 25.0[7.5] Additional Refrigerant Charge Per Additional Piping Length oz./Ft.[g/m] 1.08[20] Gas Pipe Size O.D.[Flared] In.[mm] 1/2[12.70] Liquid Pipe Size O.D.[Flared] In.[mm] 114[6.35] Piping Maximum Piping Length Ft.[m] 100(30] Maximum Height Difference Ft.[m] 50[15] Maximum Number of Bends 10 NOTES: AHRI Rated Conditions 'Cooling(Indoor//Outdoor) °F 80 DB,67 WB H 95 DB,75 WB (Rated data is determined at a fixed compressor speed) 'Heating at 47°F(Indoor H Outdoor) °F 70 DB,60 WB H 47 DB,43 WB 'Heating at 177(Indoor H Outdoor) °F 70 DB,60 WB H 17 DB,15 WB Conditions 4Heating at 5°F(Indoor H Outdoor) °F 70 160 WB H 5 DB,4 WB `Indoor/Outdoor Unit Operating Temperature Range(Cooling Air Temp[Maximum/Minimum]): •Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. "Outdoor Unit Operating Temperature Range(Cooling Thermal Lock-out/Re-start Temperatures;Heating Thermal Lock-out/Re-start Temperatures): •System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. ©2024 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. INDOOR ACCESSORIES: MSZ-GS18NA Backup Heat Relay Kit Adapter for CN24 or CN152 on ducted models ❑ CN24RELAY-KIT-CM3 IT Extender for kumo station" ❑ PAC-WHS011E-E kumo station'"for kumo cloud" ❑ PAC-WHS01HC-E Control Interface M-Net&1/0 Control Interface for M-Series ❑ MAC-3341F-E Procon BACnef and Modbus°Interface ❑ PAC-UKPRC001-CN-1 USNAP Adapter for Demand Response ❑ PAC-WHS01UP-E Wireless Interface for kumo cloud® ❑ PAC-USWHS002-WF-2 Remote Sensor Wireless temperature and humidity sensor for kumo cloud® ❑ PAC-USWHS003-TH-1 Deluxe MA Wired Remote Controllers ❑ PAR-41 MAAU Wired Remote Controller Simple Ductless Wired Remote Controller ❑—PAC-SDW01RC-1 Simple MA Remote Controller ❑ PAC-YT53CRAU-J Touch MA Wired Remote Controller ❑ PAR-CT01 MAU-SB kumo touch"RedLINK"Wireless Controller&Receiver kit ❑ MHK2 Wireless Remote Controller Lockdown Bracket for Wireless Handheld Remote Controllers ❑ RCMKPICB Blue Diamond(Advanced)Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] ❑ X87-721 Blue Diamond(MaxiBlue Advanced)Mini Condensate Pump w/Reservoir&Sensor(110V)up to 48,000 BTU/H [recommended] ❑ X87-711 . ............. Blue Diamond(MegaBlueAdvanced)Condensate Pump w/Reservoir&Sensor 0X87-835 Blue Diamond Alarm Extension Cable-6.5 Ft. ❑ C13-192 Condensate Blue Diamond MultiTank—collection tank for use with multiple pumps ❑ C21-014 Blue Diamond Sensor Extension Cable—15 Ft. ❑ C13-103 Drain Pan Level Sensor/Control ❑ SS610E Fascia Kit for MicroBlue Pump,mounts the MicroBlue and sensor directly beneath indoor unit ❑ T18-016 Sauermann Condensate Pump ❑ S130-230 Disconnect Switch (30A/600V/UL)[fits 2"X 4"utility box]-Black ❑ TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White ❑ TAZ-MS303W Filter Anti-allergy Enzyme Filter ❑ MAC-408FT-E NOTES: 1Requires MAC-3341F-E •M-Series EZ FIT'Recessed Ceiling Cassette,Floor-mount and Wall-mount Allows indoor units to connect to an MA Controller: Deluxe MA Remote Controller Simple MA Controller Touch MA Controller Specifications are subject to change without notice. ©2024 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. OUTDOOR UNIT ACCESSORIES: Air Outlet Guide Air Outlet Guide ❑ MAC-886SG-E Hail Guards Hail Guard ❑ HG-A7 100'x 1/4"x 100'/1/2"Lineset(Twin-Tube Insulation) ❑ MLS141212T-100 15'x 1/4"x 15'/1/2"Lineset(Twin-Tube Insulation) ❑ MLS141212T-15 Lineset 30'x 1/4"x 30'/112"Lineset(Twin-Tube Insulation) ❑ MLS141212T-30 50'x 1/4"x 50'/1/2"Lineset(Twin-Tube Insulation) ❑ MLS141212T-50 65'x 1/4"x 65'/1/2"Lineset(Twin-Tube Insulation) ❑ MLS141212T-65 Mounting Pad Condensing Unit Mounting Pad:16"x 36"x 3" ❑ ULTRILITE1 18"Single Fan Stand ❑ QSMS1801M 24"Single Fan Stand ❑ QSMS2401 M Stand Condenser Wall Bracket ❑ QSWB2000M-1 Condenser Wall Bracket-Stainless Steel Finish ❑ QSWBSS Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic ❑ DSD-400P Outdoor Unit Stand—12"High ❑ OSMS1201 M Specifications are subject to change without notice. ©2024 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. INDOOR UNIT DIMENSIONS: Unit: inch 7/16-13/16 Installation plate Oblong hole Indoor unit 1■7/16 Oblong hole 3-11/16 36-5/16 3.11/16 8-7/8 8.7/8 35-13/16 14 � O 9-13/16 ,u 8-11116 8-1/16 3/16 2-5/16 15-7/8 15-3/16 3 Air inWall hole 03 Installation plate 0 r2l 2-1/16 27-15/16 6-5116 Pipin �I V�V n �Drainhose z-s/e _� �_ „ 3/4 � 2-/ � ���� 4-1/21/2 Air out 5-3/4 2-9116 -11/6 m n _ 3-11i16 _I m Insulation o2 OD Wireless remote A Q Liquid line o5/16 15-3/8 Flared connection o114 controller iK Gas line o15/32 13-3/8 Flared connection o1/2 Drain hose Insulation of-5/32 Connected part o5/8 O.D Specifications are subject to change without notice. ©2024 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. OUTDOORMUZ-GS18NAHZ Unit: inch 0 ww�m� REQUIRED SPACE JoN« U o O-0 m N¢?m 4 in OR MORE. 14 in OR MORE. • 16-7/16 AIR IN DRAIN HOLE o1-21/32 N m AIR IN OPE 1 T'vOSIDES OF R'GI--, 41n OR MORE. m z OR REAR SIDE. AIR OUT 1-9/16 '•�T OVAL HOLES 2.3/8.13/16 HANDLE 13 19/32 f SERVICE PANEL LIQUID REFRIGERANT PIPE JOINT m .. VALVE COVER i� zz M N CN M W � • � y WO r 6-7/8 19-11/16 SERVICE POR 7-11/16 GAS REFRIGERANT 33-1/16 3-3/16 PIPE JOINT 11 Ir.iIr= P 'I FLARED o8.35(1/4") zFt�tkADI GS18:FLARED o12.71V2') GS24130/36:FLARED o15.88(5/8") 1340 Satellite Boulevard Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com �Wff Eta �s FORM#MSZ-GS18NA&MUZ-GS18NAHZ-202406 Intertek Specifications are subject to change without notice. ©2024 Mitsubishi Electric Trane HVAC US LLC.All rights reserved.