Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17.026 SKS Bottling Facility Plans As-Built
c 2 Mpl Ash "Sprc \ p\ 0)0) any 2-up/ \ �00 c f 2 Npl (tYP)ra 2Mpl i "Sprc � (fip) AM 2 Mply tx��s r 1 "SprcAh 2 Mpf 2"Mpl 1 Asphalt � •-1 :t i* 26'-12" HOPE 2"Chry+ ' to r Inftltroto188Units O 0.50 �F ply 2"Chry Curb oncre 1 6 Rows of Rim=315.92 2"Chry e,' 56 Bott=303.99 j� Stan Conc. 1� Vent 51'-12" SDR 26 56c 0 2"Chr O 1.35X 186.0' 31 2"Chr o Conc. Cb R1m-31 Z 18 2 Api yW� 1240 /nv-312.88 Shrup �m-317 8 DK :Conc $tt=31 �. 2"Chr ? Rim 31B.14 0 Boft 312.107 2'Chr 63.0' 2 Mal �A 1 1 62 A 0 O 2 � 1 11 5 Rowsoofr0 Units Pad 1 1 1 1 140'-12" HDP£ 1 00.5% J _� Rm=3/ B.99 Reference Map North par LEGEND: Evergreen Tree, Spruce or Shrub 27 2p \\ \\� Deciduous Tree, Maple, Linden or Cherry P y fC Nester\#10 Skyward Drive j t �� ;r: � Light Pole xW. ' ''Transa 1,' Gonc. x+.her -ro- Sign \ \ fi3. Grinder 44 geanout. 2 Jn Pump Gas gewer en. 1+ h Fire Hydrant Y 2 2 Mpl Lin Box o a 't 5' c'po Utility Pole Aft 5 0 1v°z. 2`MpJ ° 1 C�c y�iJ t ❑ Catch Basin 196, Or �� 2`LYn i k k s Cb O Catch Basin 2" HDPE 1 `g f } Pressure Sewer 0 1 1>e yyy 4 Guy 1 Cones jg N Water Gate Valve Wire V2"Lin �a/�e Vent ppPipes S Overhead Utility Lines 1 A 3 1 N; pock R/m=31763 1' f'' o 2"Lin 1 f Lpadin9 0 4/ Y QS Sewer Manhole �k'4 ,4 1 To 1 3050 y �, 7 Stone r} %£ S U.G. Sewer Line Mh 41p rog` 1 a 5 W U.G. Water Line Rim=316 Sign 2 Sprc o w Bollords G U.G. Gas Line i� Planter 1 c a 1 Concrete Compactor c) ti ',. Z 0 j] Shrubs 11 m 1 g�, Loadin ppCk Van# cn �S ` WV DW Ll f 1 i�j ® DrjM1YelJ WV •- r+i -^� 11YY? r' 45' y 44'-12" HDPE L ' r 7 772 50' 4 O 0.5X W Tee HYD r iiF %O �r,� 2"LIn - Concrete 1 40°-12" �-� 77Si/' tl�%o 2""Lin s/�pm-319.47 0 1.25X 8" CL W3yn •�• lnv=312.85 3 300' W DIP` r,4 h /yybHYD 1 c,` Sc' jft2lln 71�F + i \ i• {• �p 2'Sprc 1 Rim=315.88 MPl 2"Lin 2 Tee W52 Conc.°! s r �O Bott=305.45 719 W 419' 8 W „ DIP Asphalt r �y 8 45' O 2Mpl 9 N21' 42' 101E ,-y 411.13 Asphalt S55' 46' 10 E _ 0.89' RiWn=310.2P To A Conc Mon Found k k k k 129.60' k '� Bott=300.00 r nds N/F Of d �Ornpany p3 201E _Found N14' 52' 30 E nce Runs_ �305.44' N,34• $' 20, 30�� k k k kk kkkk kkkk kX�N83' 40' 50"Ekk i Rim=3f0.36 And ScAft h�� eadY RaPa 456 To A Carl Mon �� _---- Genear°lly AlongaProperty Line `! "� \ 3�, 3�~� S17° 52° N0 k k r C 30"W - 1.16' k k k k k k 69.68' k k ' k O Bott=300.00 Saratoga e ok 1036 0f 0 • _� �619 a N14' 55' 20"G 7o A Conc Mon A- round a _�k kkk kkkkkkkkkk-Ir Arkkkkkkkkk V Al Al ,0 Oa NdJO O �O • ?96'Sfi' N14' 50' 401E - 0.12'_ 2$8.5 Limits Of Zone AE k k k N Y.S.D.EC. Wetlands' k k k k k!" DETAIL 20.00 ' c • • •-To A Conc Mon Found \ \ Flood Hazard (See Note 6) k k k k k k r „ , • 0C► 101: O : �� `� • _ \ �. \kkkk kkkk kkkk A. kk Scale: 1 = 60 NO V "'���/// r✓ 1 Infoiratt�13�n(tq / kk k kk k kk k k S60' 58' 50"W - 0.24' _ 15 Rows 111 / k k k k k k � I) To A Conc Mon Found ed J k k 2 1 io I • 1.W t of A- _ / k k k k I� QOg I• • 186. o' O I . Cb Cb 7 p0 B I fer / kk kk k 144.0' 63.0' l 7.4'f �00 NOTES: 1. NO ATTEMPT WAS MADE TO SHOW UNDERGROUND IMPROVEMENTS IN THE PREPARATION OF THIS SURVEY. 2. ONLY BOUNDARY SURVEY MAPS WITH THE SURVEYOR'S EMBOSSED SEAL ARE GENUINE TRUE AND CORRECT COPIES OF THE SURVEYOR'S ORIGINAL WORK AND OPINION. 3. COPYRIGHT © 2018 BY GILBERT VANGUI.DER LAND SURVEYOR, PLLC ALL RIGHTS RESERVED. REPRODUCTION OR COPYING OF THIS DOCUMENT MAY BE A VIOLATION OF COPYRIGHT LAW UNLESS PERMISSION OF THE AUTHOR AND/OR COPYRIGHT HOLDER IS OBTAINED. 4. CERTIFICATIONS HEREIN ARE NOT TRANSFERABLE, UNLESS OTHERWISE NOTED. 5. THE LOCATION OF UNDERGROUND IMPROVEMENTS OR ENCROACHMENTS ARE NOT ALWAYS KNOWN AND OFTEN MUST BE ESTIMATED. IF ANY UNDERGROUND IMPROVEMENT OR ENCROACHMENTS EXIST OR ARE SHOWN, THE IMPROVEMENTS OR ENCROACHMENTS ARE NOT COVERED BY THIS CERTIFICATE. 6. SPECIAL FLOOD HAZARD AREAS INDICATED HEREON AS DIGITIZED FROM FLOOD INSURANCE RATE MAP PANEL 429 OF 693, MAP NUMBER 36091CO429 E, EFFECTIVE DATE AUGUST 16, 1995. 7. ELEVATION DATUM PER NGVD 1929 DEED REFERENCE: CONVEYANCE TO TWINBROOK REALTY, LLC, DATED OCTOBER 13, 2017 BY DEED RECORDED IN THE SARATOGA COUNTY CLERK'S OFFICE ON OCTOBER 17, 2017 AS INSTRUMENT NO. 2017032988. MAP REFERENCE: MAP ENTITLED, "SKS SUBDIVISION" DATED MARCH 30, 2017, PREPARED BY NACE ENGINEERING, PC (SHEET S-2) AND FILED IN THE SARATOGA COUNTY CLERK'S OFFICE AS MAP M2017175. b 0 a O 05 o Orywe 0 q Rim- 30.31 U. G. Te% �+ 18 & F.O. N60' 30' 50 "W Q61.80' w ®; a O y NN I O (See Map Reference) "d Forcamain 85.8„r (3) 2" HOPE DR 9 537' - 2, 30 2" HDPE N0�' 08 �f Pressure Sewer �j R = 970.00' G 5 J / / I, TOM NACE, REGISTERED PROFESSIONAL ENGINEER N0. 55,150, IN THE STATE �._ / OF NEW YORK WAS RETAINED BY TWINBROOK REALTY LLC TO UNDERTAKE OR See Mop Reference CAUSE TO BE PERFORMED BY STAFF MEMBERS UNDER MY SUPERVISION, CL #10 Skyward Drive- ( P ) / INSPECTIONS, AND REPORTS AND HEREBY CERTIFY THAT THIS DRAWING i CA STAMPED BY ME AS "AS -BUILT" HAS BEEN COMPLETED IN ACCORDANCE WITH • �\ \\Bu\ �Sr Area a 22.26f Acres / THE APPROVED DRAWINGS AND SPECIFICATIONS AND ANY AUTHORIZED o Steel/MetaJ Building p Street Address 10 Skyward Drive / CHANGES AND SHOWS THE ACTUAL FACILITIES AND INFRASTRUCTURE AS THEY 3 a I \68 0' / WERE INSTALLED IN THE FIELD. Ln @t E star / rn 03 c ` / m • Q Gas / 2 / THOMAS W. NACE, P.E. No. 55,150 19s' 1 � Guy 2" HOPE Wire Pressure Sewer 5 1 j ` ; \\\ / L 1 1 KEVIN H WEED, REGISTERED LAND SURVEYOR N0. 51,005 IN THE 3TATE OF NEW YORK WAS RETAINED BY TWINBROOK REALTY LLC TO UNDERTAKE OR • ,y� 1 i c 1 305.0 o J / CAUSE TO BE PERFORMED BY STAFF MEMBERS UNDER MY SUPERVISION, 5g ® 0** ° 8 I INSPECTIONS AND REPORTS AND HEREBY CERTIFY THAT THIS DRAWING 1 ro STAMPED BY ME AS "AS -BUILT" HAS BEEN COMPLETED IN ACCORDANCE 567' / G 45 • ow 1 1 0 WV / 2" HOPE /50' ly���. 1 a Tee H y} / Pressure Sewer / G 52 3 p0' 8" DIP CL D P CL 52 / G o� �� r • W 419 8 / N /� 0f Corp, 23 S / DW . l 1* � Tee 6 G /595.25 Bott=305.45 /Y`� j19pipaCL 52 W / L605 iltiot� Pt po9 65 Gas Service h°1t 52 Guy \ 45 / / e'GQ 1 Dee, GG a" pIP CL WireNp is O 50 1 601 0 f'.0' _,. j9 R Easamant 8 / a MH / L = 286.8� -/ k'� Sewer Gd�- 5 31 Boxer N15' 36' 50"E �=_242 74' 303'p W Guy er �Ch'�p8' 3 Wire Bo Asphalt �_ 50 �- 5 257.6' - - R = 1030.00' 600' L = 364.60' S15. 36' 50"W 8" DIP Watermaln ,1f1r Rim=310.36 / Stlwl rnP bra (See Map Reference) \ Ole � 01. 01, 20 p�on9 GeneraU� nce Pins e d Vf�ra B orbs Per Comments - 316119 PB#17.026 ASBUILT SURVEY LOT 3 (#10 SKYWARD DRIVE) SKS SUBDIVISION CITY OF SARATOGA SPRINGS SARATOGA COUNTY, NEW YORK MAP NUMBER: 09 - 24 - 78C SCALE: 1" = 100' DATE: OCTOBER 31, 2018 Gilbert VanGuilder Land Surveyor, PLLC Professional Land Surveyors 988 Route 146, Clifton Park, New York 12065 KEVIN H. WEED, P.L.S. No. 51,005 Telephone: (518) 383-0634 gvglandsurveyors. com Roalf?2A