Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20250024 191 Caroline Street Mini Split Photos & Spec Sheet
Site pictures James Sautter 191 Caroline St, Saratoga Springs, NY 12866 Picture 1: Outdoor unit will be place outside back yard right side when facing the street. Picture 2: Line set run will go through the crawl space to hide it from outside Picture 3: Line set from basement will come out from left front side and will have line set cover and enter into house. Picture also shows where indoor wall unit will mount. Picture 4: Outdoor distance from house. Picture 5: Pictures shows approx placement will be in between the two wooden poles. This is facing the street view. Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Job Name: System Reference:Date: Indoor Unit MSZ-GS18NA Outdoor Unit MUZ-GS18NAHZ INDOOR UNIT FEATURES • Slim wall-mounted indoor units provide zone comfort control • Dual Barrier Coating applied to the heat exchanger, vanes and fan to prevent hydrophilic and hydrophobic dirt build-up • Optional Microparticle Filter designed to capture PM2.5 • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button • Built-in backup/auxiliary heater control available • Multiple fan speed options: Quiet, Low, Medium, High, Super-high, Auto • Multiple control options available: ○Back-lit screen handheld remote controller (provided with the unit) ○kumo cloud® smart device app for remote access ○Third-party interface options ○Wired or wireless controllers OUTDOOR UNIT FEATURES • INVERTER-driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • Hyper-heating performance offers 100% heating capacity at 5°F • Hot-Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet outdoor unit operation • Built-in base pan heater • Innovative DC fan motor leads to high efficiency and reliability • Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life ○Rated for 2,000 hours spraying time per ASTM B117 Standard MSZ-GS18NA & MUZ-GS18NAHZ18,000 BTU/H WALL-MOUNTED INDOOR UNIT18,000 BTU/H HYPER HEAT PUMP OUTDOOR UNIT Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: MSZ-GS18NA & MUZ-GS18NAHZ test Cooling at 95°F1 Maximum Capacity BTU/H 22,000 Rated Capacity BTU/H 18,000 Minimum Capacity BTU/H 5,800 Maximum Power Input W 2,150 Rated Power Input W 1,340 Moisture Removal Pints/h 3.8 Sensible Heat Factor 0.77 Power Factor [208V / 230V]%98.0 / 98.0 Heating at 47°F2 Maximum Capacity BTU/H 25,000 Rated Capacity BTU/H 19,000 Minimum Capacity BTU/H 6,600 Maximum Power Input W 4,000 Rated Power Input W 1,340 Power Factor [208V / 230V]%98.0 / 98.0 Heating at 17°F3 Maximum Capacity BTU/H 22,400 Rated Capacity BTU/H 11,700 Maximum Power Input W 3,570 Rated Power Input W 1,230 Heating at 5°F4 Maximum Capacity BTU/H 19,000 Maximum Power Input W 3,520 Heating at -5°F6 Maximum Capacity BTU/H 16,460 Heating at -13°F7 Maximum Capacity BTU/H 13,930 Efficiency SEER2 21.5 EER21 13.45 HSPF2 [IV]9.6 COP at 47°F2 4.16 COP at 17°F at Maximum Capacity3 1.84 COP at 5°F at Maximum Capacity4 1.58 COP at -5°F at Maximum Capacity6 1.42 COP at -13°F at Maximum Capacity7 1.25 ENERGY STAR® Certified Yes Electrical Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating [SCCR]kA 5 Recommended Fuse/Breaker Size (Outdoor)A 20 Recommended Wire Size [Indoor - Outdoor]AWG 14 Power Supply Indoor unit is powered by the outdoor unit Indoor Unit MCA A 1.0 Fan Motor Full Load Amperage A 0.74 Fan Motor Output W 40 Airflow Rate at Cooling, Dry CFM 250–325–407–511–629 Airflow Rate at Cooling, Wet CFM 225–292–367–460–566 Airflow Rate at Heating, Dry CFM 287–375–459–550–629 Sound Pressure Level [Cooling]dB[A]28–33–38–44–49 Sound Pressure Level [Heating]dB[A]28–34–39–43–48 Drain Pipe Size In. [mm]5/8 [15.88] Coating on Heat Exchanger Dual Barrier Coating External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W x D x H: In. [mm]36-5/16 x 9-13/16 x 12 [923 x 250 x 305] Package Dimensions W x D x H: In. [mm]39 x 13 x 15 [990 x 330 x 380] Unit Weight Lbs. [kg]28 [12.4] Package Weight Lbs. [kg]32 [14.2] Indoor Unit Operating Temperature Range Cooling Intake Air Temp [Maximum / Minimum]*°F 90 DB, 73 WB / 67 DB, 57 WB Heating Intake Air Temp [Maximum / Minimum]°F 80 DB / 70 DB NOTES: AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB *Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SPECIFICATIONS: MSZ-GS18NA & MUZ-GS18NAHZ test Outdoor Unit MCA A 18.0 MOCP A 20 Fan Motor Full Load Amperage A 0.93 Airflow Rate [Cooling / Heating]CFM 1800 / 1646 Refrigerant Control LEV Defrost Method Reverse Cycle Coating on Heat Exchanger Blue Fin Coating Sound Pressure Level, Cooling1 dB(A)54 Sound Pressure Level, Heating2 dB(A)55 Compressor Type DC inverter driven Twin Rotary Compressor Model SNB172FQKMT Compressor Rated Load Amps A 13.6 Compressor Locked Rotor Amps A 17.0 Compressor Oil [Type // Charge]oz.FV50S // 11.8 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Built-in Unit Dimensions W x D x H: In. [mm]33-1/16 x 13 x 34-5/8 [840 x 330 x 880] Package Dimensions W x D x H: In. [mm]38-3/4 x 16-3/4 x 39 [980 x 420 x 990] Unit Weight Lbs. [kg]118 [53] Package Weight Lbs. [kg]136 [62] Outdoor Unit Operating Temperature Range Cooling Air Temp [Maximum / Minimum]*°F 115 DB / 14 DB Cooling Thermal Lock-out / Re-start Temperatures**°F -4 / 0 Heating Air Temp [Maximum / Minimum]°F 75 DB, 65 WB / -13 DB, -14 WB Heating Thermal Lock-out / Re-start Temperatures**°F -22 / -14 Refrigerant Type R410A Pre-Charged Refrigerant Amount Lbs, oz 3.0, 7.0 Maximum Pre-Charged Piping Length Ft. [m]25.0 [7.5] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m]1.08 [20] Piping Gas Pipe Size O.D. [Flared]In.[mm]1/2 [12.70] Liquid Pipe Size O.D. [Flared]In.[mm]1/4 [6.35] Maximum Piping Length Ft. [m]100 [30] Maximum Height Difference Ft. [m]50 [15] Maximum Number of Bends 10 NOTES: AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB *Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. INDOOR UNIT ACCESSORIES: MSZ-GS18NA Control Interface Backup Heat Relay Kit Adapter for CN24 or CN152 on ducted models CN24RELAY-KIT-CM3 IT Extender for kumo station™ PAC-WHS01IE-E kumo station™ for kumo cloud® PAC-WHS01HC-E M-Net & I/O Control Interface for M-Series MAC-334IF-E Procon BACnet® and Modbus® Interface PAC-UKPRC001-CN-1 USNAP Adapter for Demand Response PAC-WHS01UP-E Wireless Interface for kumo cloud® PAC-USWHS002-WF-2 Remote Sensor Wireless temperature and humidity sensor for kumo cloud® PAC-USWHS003-TH-1 Wired Remote Controller Deluxe MA Wired Remote Controller† PAR-41MAAU Simple Ductless Wired Remote Controller PAC-SDW01RC-1 Simple MA Remote Controller PAC-YT53CRAU-J Touch MA Wired Remote Controller PAR-CT01MAU-SB Wireless Remote Controller kumo touch™ RedLINK™ Wireless Controller & Receiver kit MHK2 Lockdown Bracket for Wireless Handheld Remote Controllers RCMKP1CB Condensate Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] X87-721 Blue Diamond (MaxiBlue Advanced) Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 BTU/H [recommended] X87-711 Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor X87-835 Blue Diamond Alarm Extension Cable — 6.5 Ft. C13-192 Blue Diamond MultiTank — collection tank for use with multiple pumps C21-014 Blue Diamond Sensor Extension Cable — 15 Ft. C13-103 Drain Pan Level Sensor/Control SS610E Fascia Kit for MicroBlue Pump, mounts the MicroBlue and sensor directly beneath indoor unit T18-016 Sauermann Condensate Pump SI30-230 Disconnect Switch (30A/600V/UL) [fits 2” X 4” utility box] - Black TAZ-MS303 (30A/600V/UL) [fits 2” X 4” utility box] - White TAZ-MS303W Filter Anti-allergy Enzyme Filter MAC-408FT-E NOTES: †Requires MAC-334IF-E • M-Series EZ FIT® Recessed Ceiling Cassette, Floor-mount and Wall-mount Allows indoor units to connect to an MA Controller: Deluxe MA Remote Controller Simple MA Controller Touch MA Controller Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. OUTDOOR UNIT ACCESSORIES: MUZ-GS18NAHZ Air Outlet Guide Air Outlet Guide MAC-886SG-E Hail Guards Hail Guard HG-A7 Lineset 100’ x 1/4” x 100’ / 1/2” Lineset (Twin-Tube Insulation) MLS141212T-100 15’ x 1/4” x 15’ / 1/2” Lineset (Twin-Tube Insulation) MLS141212T-15 30’ x 1/4” x 30’ / 1/2” Lineset (Twin-Tube Insulation) MLS141212T-30 50’ x 1/4” x 50’ / 1/2” Lineset (Twin-Tube Insulation) MLS141212T-50 65’ x 1/4” x 65’ / 1/2” Lineset (Twin-Tube Insulation) MLS141212T-65 Mounting Pad Condensing Unit Mounting Pad: 16” x 36” x 3” ULTRILITE1 Stand 18” Single Fan Stand QSMS1801M 24” Single Fan Stand QSMS2401M Condenser Wall Bracket QSWB2000M-1 Condenser Wall Bracket - Stainless Steel Finish QSWBSS Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic DSD-400P Outdoor Unit Stand — 12” High QSMS1201M Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. PipingInsulationø2 O.D Liquid lineø5/16 15-3/8 (Flared connection ø1/4) Gas lineø15/32 13-3/8 (Flared connection ø1/2) Drain hose Insulation ø1-5/32 Connected part ø5/8 O.D2-1/42-1/2 9-13/16 3/16 35-13/16 36-5/16 1/4 27-15/16 6-5/162-1/1612 2-9/16 2-13/162-1/22-9/16 3-11 /16 2-1/169-7/1610-5/161/88-7/88-7/83-11/16 8-3/410-3/82-5/16 15-7/8 8-11 /16 3-11 /16 7/81×7/16 Oblong hole 7/16×13/16Oblong holeInstallation plate Indoor unit Wall hole Ø3Air in Installation plate 8-1/16 15-3/161-5/88-11/163 1-11/162-9/16 2-9/164-1/2 5-3/41/4Air out Piping Drain hose3-15/162-3/8 3/4 7-5/8Unit: inch Wireless remote controller INDOOR UNIT DIMENSIONS: MSZ-GS18NA FORM# MSZ-GS18NA & MUZ-GS18NAHZ - 202406 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 13216-7/16 1-9/16 13-3/414-5/815-3/811/16OVAL HOLES 2× 3/8 ×13/16 AIR IN AIR IN AIR OUT BOLT PITCH FORINSTALLATIONDRAIN HOLE ø1-21/32 13 34-5/817-25/325/166-7/8 19-11/16 33-1/16 3-3/16 HANDLE 3-29/326-1/243357-11 /16 19/32 GAS REFRIGERANT PIPE JOINT LIQUID REFRIGERANT PIPE JOINT SERVICE PA NEL VA LVE COVER SERVICE PORT 4 in OR MORE.BASICALLY OPEN20 in OR MORE WITHOUTANY OBSTRUCTIONIN FRONT AND BOTHSIDES OF THE UNIT.14 in OR MORE. 20 in OR MORE. OPEN TWO SIDES OF RIGHT OR REAR SIDE. 4 in OR MORE. GS18: FLARED ø12.7 (1/2”) GS24/30/36: FLARED ø15.88 (5/8”) FLARED ø6.35 (1/4”) REQUIRED SPACE Unit: inch OUTDOOR UNIT DIMENSIONS: MUZ-GS18NAHZ