Loading...
HomeMy WebLinkAbout20190761 Small Cell Antenna Node 11 Revised Plans Prepared By: INFINIGY8 atactINFINIGY ENGINEERING,PLLC 1033 Watervliet Shaker Rd Albany,NY 12205 Office#(5181690-0790 Fax#(5181690-0793 4E ° yE or S STp 4: '1 IP CRANRUNYSTOG1 NODE 11 tti ., _ fid Q71096 F AROfiESS1O ' NM 10 UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS A VIOLATION OF APPDCABLE STATE AND/OR LOCAL LAWS 37 MARION AVE SARATOGA SPRINGS, NY 1IO RNSE/UESONIPTERNT 85//219//119 No Submlt[allRevlslon App'd trate Pro ect Number: I Drawn: 9(R Date:l0/17/Is igned:Asw Date:l0/17/Is DRAWING INDEX VICINITY MAP PROJECT DIRECTORY 665-003 DeCs ecked: Ado Date:to DRWG.# TITLE REV.# DATE STRUCTURE OWNER: NATIONAL GRID Project Tiue: T-1 TITLE SHEET 1 08/29/19 300 ERIE BLVD.WEST CRANRUNYSTOG1 SYRACUSE,NY 13202 _ _ G-1 GENERAL NOTES 1 08/29/19 ,w.B CONTACT: TBD NODE 11 A-1 SITE LOCATION AND ELEVATION 1 08/29/19 Y- 3 A-2 EQUIPMENT DETAILS 1 08/29/19 APPLICANT: AT&T MOBILITY N M 10 .'90.sem•-I:.rn•r�°) 5841 BRIDGE STREET E-1 UTLTY&GROUNDING DETAILS 1 08/29/19 `.`w.-G! EAST SYRACUSE,NY 13057 37 MARION AVE CONTACT: TBD SARATOGA SPRINGS,NY 12866 ........4 MOOS Prepared For: PROJECT MANAGER: CEE 4bin. 95NRYANINDRIVE SUITE 1 T1k *,RAYNHAM,MA 02767 at8ct re�Er�nula.mlljr CONTACT: CHRISTINE HOWELL """ (508)692-8553 ,..—.-- Fe. THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF AT&T AND MAY NOT BE REPRODUCED, y ENGINEER: INFINIGY DissEMINATED oR REDisTcME ED vv TAtir THE 1033 WATERVLIET SHAKER ROAD ExPREss LVRITTEN coNSENr of ATsr. ALBANY,NY 12210 Project Manager: NCONTACT: ALEX WELLER PHONE:(518)690-0790 PROJECT INFORMATION DRIVING DIRECTIONS CODE COMPLIANCE •�CENTERLINE FROM:5841 BRIDGE STREET EAST SYRACUSENY 13057 v_COMMUNICATIONS , SITE NAME: CRAN_RUNY_STOGi NODE 11 ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALL IN ACCORDANCE WITH THE CURRENT HEAD SOUTHWEST ON BRIDGE ST.USE THE LEFT 2 LANES TO TURN LEFT ONTO WIDEWATERS PKWY.MAKE A EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES.NOTHING 95 Ryan Drive Suite 1 Raynnam:MAoz;sT SITE ADDRESS: 37 MARION AVE U—TURN.USE THE MIDDLE LANE TO TURN RIGHT AT THE 1ST CROSS STREET ONTO BRIDGE ST.TURN LEFT olfice:Tel.Tls.aTzs-Fax:al-sal-sue ONTO THE INTERSTATE 690E RAMP TO INTERSTATE 481.MERGE ONTO 1-690 E.USE THE LEFT LANE TO TAKE IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. SARATOGA SPRINGS,NY 12866 1. INTERNATIONAL BUILDING CODE(2015 IBC) THE INTERSTATE 481 N EXIT TOWARD INTERSTATE 90/THRUWAY.MERGE ONTO I-481 N.TAKE EXIT 6 TO 2. TIA—EIA-222—G OR LATEST EDITION Drawing Scale: TiCOUN: SARATOGA MERGE ONTO I-90 E.TAKE EXIT 27 FOR NY-30 TOWARD AMSTERDAM.USE THE RIGHT 2 LANES TO TURN CD RIGHT ONTO NY-30 N(SIGNS FOR NY-5S).KEEP RIGHT TO CONTINUE ON NY-67 E/CHURCH ST.CONTINUE TO 3. NFPA 780—LIGHTNING PROTECTION CODE AS NOTED ZONING JURISDICTION: CITY OF SARATOGA FOLLOW NY-67 E.CONTINUE STRAIGHT ONTO E HIGH ST.TURN LEFT ONTO HYDE BLVD.TURN RIGHT ONTO 4• 2011 NATIONAL ELECTRIC CODE OR LATEST EDITION Date: MALTA AVE.TURN LEFT ONTO U.S.9 N.USE THE RIGHT LANE TO TAKE THE RAMP ONTO 1-87 N.FOLLOW 5. ANY OTHER NATIONAL OR LOCAL APPLICABLE CODES,MOST RECENT EDITIONS 6. NYS BUILDING CODE 8/29/19 STRUCTURE TYPE: UTILITY POLE 1-87 N TO NY-50 S/NY-29 TRUCK E IN SARATOGA SPRINGS.TAKE EXIT 15 FROM 1-87 N 7. LOCAL BUILDING CODE MERGE ONTO 1-87 N.TAKE EXIT 15 FOR NY-50 TOWARD SARATOGA SPRINGS/GANSEVOORT.FOLLOW NY-50 Drawing Title 8. CITY/COUNTY ORDINANCES LATITUDE: 43.092404'N S/NY-29 TRUCK E TO MARION AVE.TURN LEFT ONTO NY-50 S/NY-29 TRUCK E.TURN RIGHT ONTO MARION AVE.DESTINATION WILL BE ON THE RIGHT TITLE SHEET LONGITUDE: 73.77094T W 811 OOwWauORWRO : TOLL FREE:1-800-962-7962 OR Drawing Number 1 � www.digsafelynewyork.com NREEWIORREsK MTIN AcNToAODTE Ko02h1bYee1W.dlg.WOFRORGSxTVA T-1 L i GENERAL CONSTRUCTION NOTES: 'Prepared By: 23. ALL EXISTING INACTIVE SEWER,WATER,GAS,ELECTRIC,AND OTHER 4. DO NOT SCALE ELECTRICAL DRAWINGS;REFER TO SITE PLANS AND 31. TELEPHONE SERVICE:CONTRACTOR SHALL PROVIDE EMPTY CONDUITS 1. FOR THE PURPOSE OF CONSTRUCTION DRAWINGS,THE FOLLOWING UTILITIES,WHICH INTERFERE WITH THE EXECUTION OF THE WORK,SHALL ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT,AND CONFIRM WITH PULL STRINGS AS INDICATED ON DRAWINGS. DEFINITIONS SHALL APPLY: BE REMOVED,CAPPED,PLUGGED OR OTHERWISE DISCONNECTED AT WITH CONSTRUCTION MANAGER'ANY SIZES AND LOCATIONS WHEN NEEDED. 32. ELECTRICAL AND TELCO RACEWAYS TO BE BURIED A MINIMUM OF 2' GENERAL SUBCONTRAC TOR CTO CONTRACTOR(CONSTRUCTION) ASSINTS DIRECTEDHBYILL NOT THE RESPONSIBLE ARCHITECT/ENGE WITH THE IN EEER,TION OANDHE WORK,SUBJJECT 5 SERVICES WITHIOUT WRITTEN PERMISSION OF THE OWNER. EXISTING 33. CONTRACTOR SHALL PLACE TWO LENGTHS OF WARNING TAPE ATA INFINIGY8 OWNER-AT&T TO THE APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES. 6. CONTRACTOR SHALL PAY FOR ANY/ALL PERMITS,FEES,INSPECTIONS,AND DEPTH OF 12"BELOW GROUND AND DIRECTLY ABOVE ELECTRICAL INFINIGY ENGINEERING,PLLC 2. ALL SITE WORK SHALL BE COMPETED AS INDICATED ON THE DRAWINGS 24. THE AREAS OF THE OWNER'S PROPERTY DISTURBED BY THE WORK AND TESTING.CONTRACTOR IS TO OBTAIN PERMITS AND APPROVED SUBMITTALS AND TELCO SERVICE CONDUITS.CAUTION TAPE TO READ"CAUTION AND AT&T PROJECT SPECIFICATIONS. NOT COVERED BY THE TOWER,EQUIPMENT OR DRIVEWAY,SHALL BE PRIOR TO THE WORK BEGINNING OR ORDERING EQUIPMENT. BURIED ELECTRIC"OR"BURIED TELECOMM." 1033 Watervliet Shaker Rd 3. GENERAL CONTRACTOR AND SUBCONTRACTOR SHALL VISIT THE SITE AND GRADED TOA UNIFORM SLOPE,AND STABILIZED TO PREVENT EROSION. Albany, 12205 7. THE TERM"PROVIDE"USED IN CONSTRUCTION DOCUMENTS AND 34. ALL BOLTS SHALL BE STAINLESS STEEL Albany,Office SHALL FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING THE 25. SUBCONTRACTOR SHALL MINIMIZE DISTURBANCE TO THE EXISTING SITE SPECIFICATIONS,INDICATES THAT THE CONTRACTOR SHALL FURNISH AND Fax#(5181690-0793 PROPOSED WORK AND SHALL MAKE PROVISIONS.GENERAL CONTRACTOR DURING CONSTRUCTION.EROSION CONTROL MEASURES,IF REQUIRED INSTALL. GROUNDING NOTES: AND SUBCONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING DURING CONSTRUCTION,SHALL BE IN CONFORMANCE WITH THE FEDERAL 8, CONTRACTOR SHALL CONFIRM WITH LOCAL UTILITY COMPANY ANY/ALL THEMSELVES WITH ALL CONTRACT DOCUMENTS,FIELD CONDITIONS, AND LOCAL JURISDICTION FOR EROSION AND SEDIMENT CONTROL. REQUIREMENTS,SUCH AS THE:LUG SIZE RESTRICTIONS,CONDUIT ENTRY, DIMENSIONS,AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED 26, NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN SIZE OF TRANSFORMERS,SCHEDULED DOWNTIME FOR THE OWNERS' 1. COMPRESSION CONNECTIONS(2),2 AWG BARE TINNED SOLID COPPER011OF i E AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION.ANY GROUNDING.FROZEN MATERIALS,SNOW OR ICE SHALL NOT BE PLACED IN CONDUCTORS TO GROUNDING BAR.ROUTE CONDUCTORS TO BURIED /`i DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE CONFIRMATION,ETC...ANY/ALL CONFLICTS SHALL BE BROUGHT TO THE GROUNDING RING AND PROVIDE PARALLEL EXOTHERMIC WELD l�j ANY FILL OR EMBANKMENT. Cj •Tkilt, ATTENTION OF THE CONSTRUCTIONMANAGER,PRIOR TO BEGINNING ANY 2. EC SHALL USE PERMANENT MARKER TO DRAW THE LINES BETWEEN 7',a�' eARCHITECT/ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 27. THE SUBGRADE SHALL BE BROUGHT TOA SMOOTH UNIFORM GRADE AND `��? WORK. EACH SECTION AND LABEL EACH SECTION 'P,""A,""N,""I"WITH !* ft�� . 4. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT COMPACTED TO 95 PERCENT STANDARD PROCTOR DENSITY UNDER ( ) 4 9. MINIMUM WIRE SIZE SHALL BE 12 AWG,NOT INCLUDING CONTROL WIRING, ACCORDANCE WITH ALL APPLICABLE CODES,REGULATIONS,AND PAVEMENT AND STRUCTURES AND 80 PERCENT STANDARD PROCTOR # 1" LETTERS. 'K WASHERS, ,LD BEFORE . W/8 INCH4.1ht Z:: gi t? AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL LAWFUL MANNER. 11. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL WASHER BETWEEN LUG AND STEEL,COAT ALL SURFACES WITH AN '''°, CODES,ORDINANCES,AND APPLICABLE REGULATIONS. 29. ALL BROCHURES,OPERATING AND MAINTENANCE MANUALS,CATALOGS, OF THE CONSTRUCTION.CONTRACTOR IS EXPECTED TO FURNISH AND ANTI-OXIDANT COMPOUND BEFORE MATING. O Q7109 F.� 6. UNLESS NOTED OTHERWISE,THE WORK SHALL INCLUDE FURNISHING SHOP DRAWINGS,AND OTHER DOCUMENTS SHALL BE TURNED OVER TO INSTALL AL ITEMS FOR COMPLETE EQUIPMENT EAPLACEDMNAND PR VIDE 5. NUT&WASHER SHALL BE PLACED ON THE FRONT SIDE OF THE AR���SS'O�P�' MATERIALS,EQUIPMENT,APPURTENANCES,AND LABOR NECESSARY TO THE GENERAL CONTRACTOR AT COMPLETION OF CONSTRUCTION AND ALL GROUNDING BAR AND BOLTED ON THE BACK SIDE. COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. PRIOR TO PAYMENT. WORKING ORDER. 6. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE 7. PLANS ARE NOT TO BE SCALED.THESE PLANS ARE INTENDED TO BEA 30. SUBCONTRACTOR SHALL SUBMIT A COMPLETE SET OF AS-BUILT REDLINES 12. ELECTRICAL SYSTEM SHALL BE AS COMPLETELY AND EFFECTIVELY OF TOWER,ANTENNA LOCATION,AND CONNECTION ORIENTATION. GROUNDED,AS REQUIRED BY SPECIFICATIONS,SET FORTY BY AT&T. DIAGRAMMATIC OUTLINE ONLY UNLESS OTHERWISE NOTED.DIMENSIONS TO THE GENERAL CONTRACTOR UPON COMPLETION OF PROJECT AND PROVIDE AS REQUIRED. UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT SHOWN ARE TO FINISH SURFACES UNLESS OTHERWISE NOTED.SPACING PRIOR TO FINAL PAYMENT. 13. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL 7. WHEN THE SCOPE OF WORK REQUIRES THE ADDITION OFA ISA VIOLATION OF APPL CABLE STATE AND/OR LOCAL LAWS BETWEEN EQUIPMENT IS THE MINIMUM REQUIRED CLEARANCE.THEREFORE, 31. SUBCONTRACTOR SHALL LEAVE PREMISES INA CLEAN CONDITION. CONTRACTOR INA FIRST CLASS,WORKMANLIKE MANNER.THE COMPLETED GROUNDING BAR TO AN EXISTING TOWER,THE SUBCONTRACTOR IT IS CRITICAL TO FIELD VERIFY DIMENSIONS,SHOULD THERE BE ANY 32. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE SYSTEM SHALL BE FULLY OPERATIVE AND SUBJECT TO REGULATORY SHALL OBTAIN APPROVAL FROM THE TOWER OWNER PRIOR TO QUESTIONS REGARDING THE CONTRACT DOCUMENTS,THE SUBCONTRACTOR POTABLE WATER OR SEWER SERVICE,AND IS NOT FOR HUMAN HABITAT INSPECTION&APPROVAL BY CONSTRUCTION MANAGER. MOUNTING THE GROUNDING BAR TO THE TOWER. SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE (NO HANDICAP ACCESS REQUIRED). 14. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID 8. ALL ELECTRICAL AND GROUNDING AT THE CELL SITE SHALL COMPLY ARCHIETCT/ENGINEER PRIOR TO PROCEEDING WITH THE WORK.DETAILS 33. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION, NTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. WITH THE NATIONAL ELECTRICAL CODE(NEC),NATIONAL FIRE ARE INTENDED TO SHOW DESIGN INTENT.MODIFICATIONS MAY BE APPROXIMATELY 2 TIMES PER MONTH,BY AT&T TECHNICIANS. 15. CONTRACTOR SHALL GUARANTEE ANY/ALL MATERIALS AND WORK FREE PROTECTION ASSOCIATION(NEPA)780(LATEST EDITION),AND RENSEO/1990E0 FOR PERNIT w 8/29/19 REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS AND SUCH 34. NO OUTDOOR STORAGE OR SOLID WASTE CONTAINERS ARE PROPOSED. FROM DEFECTS FORA PERIOD OF NOT LESS THAN ONE YEAR FROM DATE MANUFACTURER. a 990E0 FOR PER. w 5/15/19 MODIFICATIONS SHALL BE INCLUDED AS PART OF WORK AND PREPARED 35. ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN OF ACCEPTANCE. Na. s"nn,IrrzlrRevlslo" Ap a ore BY THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH WORK. ACCORDANCE WITH THE LATEST REVISION OF AT&T MOBILITY GROUNDING 16. THE CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ANY ADDITIONAL CHARGE AND SHALL INCLUDE THE REPLACEMENT OR THE Project Number: Drawn: 9B Date:ro/r/re 8. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN STANDARD"TECHNICAL SPECIFICATION FOR CONSTRUCTION OF GSM/GFRs REPAIR OF ANY OTHER PHASE OF THE INSTALLATION,WHICH MAY HAVE Designed:nsw Date:+o/+/re ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS WIRELESS SITES"AND"TECHNICAL SPECIFICATION FOR FACILITY BEEN DAMAGED THEREIN. 665003 SPECIFICALLY STATED OTHERWISE. GROUNDING."IN CASE OFA CONFLICT BETWEEN THE CONSTRUCTION Checked: neo Date:t0/r7/rR 9. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON 17. ADEQUATE AND REQUIRED LIABILITY INSURANCE SHALL BE PROVIDED FOR SPECIFICATION AND THE DRAWINGS,THE DRAWINGS SHALL GOVERN. PROTECTION AGAINST PUBLIC LOSS AND ANY/ALL PROPERTY DAMAGE FOR Project title: THESE DRAWINGS.THE SUBCONTRACTOR SHALL PROPOSE AN 35. SUBCONTRACTORS SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS THE DURATION OF WORK. ALTERNATIVE SPACE FOR APPROVAL BY THE ARCHITECT/ENGINEER PRIOR AND INSPECTIONS REQUIRED FOR CONSTRUCTION.IF SUBCONTRACTOR 18. PROVIDE AND INSTALL CONDUIT,CONDUCTORS,PULL WIRES,BOXES,COVER CRANRUNYSTOG1 TO PROCEEDING. CANNOT OBTAIN A PERMIT,THEY MUST NOTIFY THE GENERAL PLATES AND DEVICES FOR ALL OUTLETS AS INDICATED. _ _ 10. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF CONTRACTOR IMMEDIATELY. 19. DITCHING AND BACK FILL:CONTRACTOR SHALL PROVIDE FOR ALL NODE 11 WORK AREA,ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE 36. SUBCONTRACTOR SHALL REMOVED ALL TRASH AND DEBRIS FROM THE UNDERGROUND INSTALLED CONDUIT AND/OR CABLES INCLUDING LIKELY TO BE SHALL CONFORM FTOCAELDL OSHA REQUIREMENTS AND THOENLOCAL BY THE VVORK UNDER THIS CTRACT.WORK 37. INIFORMATIONDASHOWNSON THESE DRAWINGS WAS OBTAINED FROM SITE EXCAVATION,BACKFILLING AND COMPACTION.REFER TO'FOUNDATION, NM1 O JURISDICTION. VISITS AND/OR DRAWINGS PROVIDED BY THE SITE OWNER.CONTRACTORS EXCAVATION,AND BACKFILLING NOTES.' 11. GENERAL CONTRACTOR SHALL COORDINATE WORK AND SCHEDULE WORK SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO 20. MATERIALS,PRODUCTS AND EQUIPMENT,INCLUDING ALL COMPONENTS 37 MARION AVE ACTIVITIES WITH OTHER DISCIPLINE. ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. THEREOF,SHALL BE NEW AND SHALL APPEAR ON THE LIST OF U.L. 12. ERECTION SHALL BE DONE INA WORKMANLIKE MANNER BY COMPETENT 38. NO WHITE STROBE LIGHTS ARE PERMITTED.ANY REQUIRED LIGHTING MUST APPROVED ITEMS AND SHALL MEET OR EXCEED THE REQUIREMENTS OF SARATOGA SPRINGS,NY 12866 EXPERIENCED WORKMEN IN ACCORDANCE 1MTH APPLICABLE CODES AND MEET FAA STANDARDS AND REQUIREMENTS. THE NEC,NEMA,AND IECE. THE BEST ACCEPTED PRACTICE.ALL MEMBERS SHALL BE LAID PLUMB 39. ALL COAXIAL CABLE INSTALLATIONS TO FOLLOW MANUFACTURER'S 21. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OR MANUFACTURERS Prepared For: AND TRUE AS INDICATED ON THE DRAWINGS. INSTRUCTIONS AND RECOMMENDATIONS. CATALOG INFORMATION OF ANY/ALL LIGHTING FIXTURES,SWITCHES,AND 13. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH UL LISTED 40. NO SIGNIFICANT NOISE,SMOKE,DUST OR VIBRATIONS WILL RESULT FROM ALL OTHER ELECTRICAL ITEMS FOR APPROVAL BY THE CONSTRUCTION MATERIALS APPROVED BY LOCAL JURISDICTION.SUBCONTRACTOR SHALL MANAGER PRIOR TO INSTALLATION. ���� THIS FACILITY.(DISREGARD THIS NOTE IF THIS SITE HAS A GENERATOR) KEEP AREA CLEAN,HAZARD FREE,AND DISPOSE OF ALL DEBRIS. 22. ANY CUTTING OR PATCHING DEEMED NECESSARY FOR ELECTRICAL WORK IS 41. NO ADDITIONAL PARKING TO BE PROPOSED.EXISTING ACCESS AND 14. WORK PREVIOUSLY COMPLETED IS REPRESENTED BY LIGHT SHADED LINES THE ELECTRICAL CONTRACTORS RESPONSIBILITY AND SHALL BE INCLUDED AND NOTES.THE SCOPE OF WORK FOR THIS PROJECT IS REPRESENTED PARKING TO REMAIN,UNLESS NOTED OTHERWISE. IN THE COST FOR WORK AND PERFORMED TO THE SATISFACTION OF THE BY DARK SHADED LINES AND NOTES.SUBCONTRACTOR SHALL NOTIFY THE 42. NO LANDSCAPING IS PROPOSED AT THIS SITE,UNLESS NOTED OTHERWISE. 'CONSTRUCTION MANAGER'UPON FINAL ACCEPTANCE. *,... GENERAL CONTRACTOR OF ANY EXISTING CONDITIONS THAT DEVIATE FROM 23. THE ELECTRICAL CONTRACTOR SHALL LABEL AL PANELS WITH ONLY rHESEDOCUMEMrsAREcoNFiDENT1ALAMDARErHE THE DRAWINGS PRIOR TO BEGINNING CONSTRUCTION. ELECTRICAL NOTES: soLEis"E'i EINZINIZ AYNOTBarjir DUCED, TYPEWRITTEN DIRECTORIES.ALL ELECTRICAL WIRING SHALL BE THE DIssEMiNArEDORREDisrRiaurEDwirHourrHE 15. SUBCONTRACTOR SHALL PROVIDE WRITTEN NOTICE TO THE CONSTRUCTION RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. ExPREssrvRirENcoNSENroFArsr. MANAGER 48 HOURS PRIOR TO COMMENCEMENT OF WORK. 1. ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ANY/ALL 24. DISCONNECT SWITCHES SHALL BE H.P.RATED HEAVY-DUTY,QUICK-MADE project Manager: 16. THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, ELECTRICAL WORK INDICATED.ANY/ALL CONSTRUCTION SHALL BE IN AND QUICK-BREAK ENCLOSURES,AS REQUIRED BY EXPOSURE TYPE. PAVEMENTS,CURBS,LANDSCAPING AND STRUCTURES.ANY DAMAGED ACCORDANCE WITH DRAWINGS AND ANY/ALL APPLICABLE SPECIFICATIONS. 25. ALL CONNECTIONS SHALL BE MADE WITH A PROTECTIVE COATING OF AN ABBREVIATIONS: PART SHALL BE REPAIRED AT SUBCONTRACTOR'S EXPENSE TO THE IF ANY PROBLEMS ARE ENCOUNTERED BY COMPLYING WITH THESE ANTI-OXIDE COMPOUND SUCH AS"NO-OXIDE A"BY DEARBORNE CIGBE COAX ISOLATED GROUND BAR EXTERNAL A;` SATISFACTION OF THE OWNER. REQUIREMENTS,CONTRACTOR SHALL NOTIFY'CONSTRUCTION MANAGER'AS CHEMICAL CO.COAT ALL WIRE SURFACES BEFORE CONNECTING.EXPOSED 17. THE SUBCONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR SOON AS POSSIBLE,AFTER THE DISCOVERY OF THE PROBLEMS,AND COPPER SURFACES,INCLUDING GROUND BARS,SHALL BE TREATED-NO MIGB MASTER ISOLATED GROUND BAR • CENTERLINE TO THE START OF CONSTRUCTION. SHALL NOT PROCEED WITH THAT PORTION OF WORK,UNTIL THE SUBSTITUTIONS. SST SELF SUPPORTING TOWER COMMUNICATIONS 18. GENERAL CONTRACTOR SHALL COORDINATE AND MAINTAIN ACCESS FOR 'CONSTRUCTION MANAGER'HAS DIRECTED THE CORRECTIVE ACTIONS TO 26. RACEWAYS:CONDUIT SHALL BE SCHEDULE 40 PVC MEETING OR EXCEEDING GPS GLOBAL POSITIONING SYSTEM ALL TRADES AND SUBCONTRACTORS TO THE SITE AND/OR BUILDING. BE TAKEN. NEMA TC2-1990.CONTRACTOR SHALL PLUG AND CAP EACH END OF 95 Ryan Drive Suite 1 Raynnam:MAoz;s 19. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF 2. ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND FAMILIARIZE SPARE AND EMPTY CONDUITS AND PROVIDE TWO SEPARATE PULL STRINGS TYP. TYPICAL olrice:7at ts.a7zs-RFTata-sal-a se THE SITE FOR THE DURATION OF CONSTRUCTION UNTIL JOB COMPLETION. HIMSELF WITH ANY/ALL CONDITIONS AFFECTING ELECTRICAL AND -200 LBS TEST POLYETHYLENE CORD.ALL CONDUIT BENDS SHALL BEA DWG DRAWING 20. THE GENERAL CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION ONE COMMUNICATION INSTALLATION AND MAKE PROVISIONS AS TO THE COST MINIMUM OF 2 FT.RADIUS.RGS CONDUITS WHEN SPECIFIED,SHALL MEET BCW BARE COPPER WIRE Drawing Scale: COMPLETE SET OF PLANS WITH ALL REVISIONS,ADDENDA,AND CHANGE UL-6 FOR GALVANIZED STEEL.ALL FITTINGS SHALL BE SUITABLE FOR FIXTURES,ETC.,THAT ARE PART OF THE FINAL SYSTEM,SHALL BE THEREOF.ALL EXISTING CONDITIONS OF ELECTRICAL EQUIP.,LIGHT BFG BELOW FINISH GRADE AS NOTED CD ORDERS ON THE PREMISES AT ALL TIMES. USE WITH THREADING RIGID CONDUIT.COAT ALL THREADS WITH'BRITE PVC POLYVINYL CHLORIDE 21. THE GENERAL CONTRACTOR AND SUBCONTRACTOR SHALL PROVIDE VERIFIED BY THE CONTRACTOR,PRIOR TO THE SUBMITTING OF HIS BID. ZINC'OR'GOLD CALV.' Date: PORTABLE FIRE EXTINGUISHERS WITH A RATING OF NOT LESS THAN 2-A FAILURE TO COMPLY WITH THIS PARAGRAPH WILL IN NO WAY RELIEVE 27. SUPPORT OF ALL ELECTRICAL WORK SHALL BE AS REQUIRED BY NEC. CAB CABINET OT 2-A:10-B:C AND SHALL BE WITHIN 25 FEET OF TRAVEL DISTANCE TO 28. CONDUCTORS:CONTRACTOR SHALL USE 98%CONDUCTIVITY COPPER WITH C 8/2919 ALL PORTIONS OF WHERE THE WORK IS BEING COMPLETED DURING CONTRACTOR OF PERFORMING ALL WORK NECESSARY FOR A COMPLETE CONDUIT CONSTRUCTION. AND WORKING SYSTEM. TYPE THWN INSULATION,800 VOLT,COLOR CODED.USE SOLID Drawing Title 3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST CONDUCTORS FOR WIRE UP TO AND INCLUDING NO.8 AWG.USE SS STAINLESS STEEL 22. ALL EXISTING ACTIVE SEWER,WATER,GAS,ELECTRIC,AND OTHER G GROUND GENERAL NOTES EDITION OF THE NEC AND ALL CODES AND LOCAL ORDINANCES OF THE STRANDED CONDUCTORS FOR WIRE ABOVE N0.8 AWG. UTILITIES SHALL BE PROTECTED AT ALL TIMES,AND WHERE REQUIRED LOCAL POWER&TELEPHONE COMPANIES HAVING JURISDICTION AND 29. CONNECTORS FOR POWER CONDUCTORS:CONTRACTOR SHALL USE AWG AMERICAN WIRE GAUGE FOR THE PROPER EXECUTION OF THE WORK,SHALL BE RELOCATED AS SHALL INCLUDE BUT NOT BE LIMITED T0: PRESSURE TYPE INSULATED TWIST-ON CONNECTORS FOR N0.10 AWG AND RGS RIGID GALVANIZED STEEL DIRECTED BY THE ARCHITECT/ENGINEER.EXTREME CAUTION SHOULD BE C-NATIONAL FIRE CODES SMALLER.USE SOLDERLESS MECHANICAL TERMINAL LUGS FOR NO.8 AWG AHJ AUTHORITY HAVING JURISDICTION USED BY THE SUBCONTRACTOR WHEN EXCAVATING OR DRILLING PIERS A. UL-UNDERWRITERS LABORATORIES AND LARGER. Drawing Number AROUND OR NEAR UTILITIES.SUBCONTRACTOR SHALL PROVIDE SAFETY B. NEC-NATIONAL ELECTRICAL CODE 30. SERVICES:240/120V,SINGLE PHASE,3 WIRE CONNECTION AVAILABLE TTLNA TOWER TOP LOW NOISE AMPLIFIER TRAINING FOR THE WORKING CREW.THIS SHALL INCLUDE BUT NOT BE C. NEMA-NATIONAL ELECTRICAL MANUFACTURERS ASSOC. FROM UTILITY COMPANY.OWNER OR OWNERS AGENT WILL APPLY FOR UNO UNLESS NOTED OTHERWISE ^ _ LIMITED TO A)FALL PROTECTION,B)CONFINED SPACE,C)ELECTRICAL D. OSHA-OCCUPATIONAL SAFETY AND HEALTH ACT POWER. EMT ELECTRICAL METALLIC TUBING IVB SAFETY,D)TRENCHING&EXCAVATION. E. SBC-STANDARD BUILDING CODE AGL ABOVE GROUND LEVEL L i 'Prepared By r VsSIDTIENNGTINAELAsRTERSuTcTuRE...L. / , ,..., t•, NI ri INFINIGY8 i ' • '' - - g Al--- ---. • 1 .-. INFINIGY ENGINEERING,PLLC ,,.ta' I'. si 1033 Watervliet Shaker Rd k... Fax#(518)690-0793 t'..7' . 0 '.t''a• re -*Ti'IS li ' '01 II" : ' -,11..' . An PROPOSED AT&T OMNI ANTENNA MOUNTED ON ' -,-.- i, ' '-_illi1k,", sx''',:sr,i,,-':'•r.....!- .a1•1._-,..1 Pk- .1. 94r,• , -. -- 4 . G,„l1„AGL /CE NTERLINE OF PPRROOEEPPLLOOEESSvVEEAADDTTiIAN 4 T&&±fTTJ..1AA,.5AN1"-TT;8EEN"INNAAAAGGSSLL•c.iP, 7,0_.-.t4,4.,...-...-N,,1,9lE .,,i,,.t,4,_r.•p',.k(. • , EXISTING UTILITY POLE Ai?C'PESSi(O's\' (POLE#NM10) _.- , .. ETSTIII SEC2NDAREY @ t27 5'E AGLE • , ? LijsNfvFliglEON AOFTE:ZTAZ AsTa°NANTAILC'AcLuifi; _....-- . . off, g-.4' —'- - , __. ....—___ ISSDED FDR PER. ,.5/15/19 DOTING SECONDARY @±21'AGL r E E— —PROPOSED(3)16 AWG WIRES No CONTRAC7OR TO PAINT ALL I ,—E—E- INSIDE PROPOSED(1)UV RATED . - . Y-29 (TRUCK) ANTENNA,CABLING,AND EQUIPMENT 1-1/4"MIN.SCH.40 PVC CONDUIT ,e"..ber Drawn EKE Data WV,. 70 MA7CH THE EXISTING POLE 6 6 5-'3 Dc=k"ee cid ',: Ze.7o/:7//:: - - - — ------— • cl, SITE PLAN 25' 0 25' 50' 10, / Project Title SCALE AS NOTED I, — ON FEET) ORAN RUNY_STOG1 CALLED NORTH sseLLEE 1212.,,,374-.sSHHEEEETT 1 1 =15000-00. NODE 11 PROPOSED RBER ROM EXIS1ING SOURCE(ROWING TBD)IN NM10 EXISTING TELCO PROPOSED 2"U-GUARD LINES(TYP) 410011 i, I Ilk Ak PROPOSED W 0) 0)Ar&T EQUIPMENT ' SHROUD{MTH(1)RRUS 4449 AND RRUS 4415 .---r,-• [1ri-T---4 --- PROPOSED RBER DEMARC l','SE", (BY RBER PROMER) 37 MARION AVE SARATOGA SPRINGS,NY 12866 PROPOSED RBER JUMPERS PROPOS.(1)100A,2 POLE (FRONIHAUL&BACKHAUL) .......—.41"-' SERVICE EN1RANCE RATED,NEMA at8ct 3R PANEL WITH 100A-2P MCB I \w EXISTING UTILITY POLE PROPOSED METER MAIN WITH 11 j (POLE#NM10) so-TEZDp'EcRurroNa-VEZTIAli,ENNIMEVRRODIZED BYPASS(METER SHALL NOT BE MOUNTED ON siREET ago D's"ETAIN=TETOTALT'T THE ill 1 ri 0/p v___,,,* CENTERLINE pwRRopE ioNssE,DDE/ uAvWGRACTE0 DPP pERvcGROUND , -COMMUNICATIONS . ------H (.TC' 't''../ 950IZ:"71:=215!Far4a13'5.'41'-n:7 It.• ' ..,r, Date AS NOTED CD GROUND LEVEL , - -4- - , -,,,, .;,, EXISIING OR PROPOSED 5/8"(V.IF0x8' COPPER CLAD GROUND ROD ) SITE LOCATION& ELEVATION .„ ___ . .. *EXISTING CONDITIONS PHOTO 0 E L E VAT I 0 N VIEW XXGX A-1 NOT TO SCALE NOT TO SCALE l. ., Prepared By: 13.2" 13.4° T 11 11 I INFINIGY8 O li ,r , I INFINIGY ENGINEERING, NGINEERING, PL LC 10Abeny7Y 52205" m 0 0 n 7.7##188))6600-9930 r i 1 ,, 4 „i_ :-,-o v, , >` ' 1n J_Ifli d 1/ -F, telt. ,Li, 10.4 5.9" , it'.4 i r c,' FRONT SIDE FRONT SIDE FO 071096 (3 UUUUUUU AROfiESs10P\' 14.6" 13.2" 13.4" IIIIIM RIII 1 O©©© p O UISNAAUVOOLRAZIEDN AOFTALIOE ASDEOANO ISLODCOACWT RRUS-4449 SPECIFICATIONS '® RRUS-4415 SPECIFICATIONS AMPHENOL C2U3MT360X06FXYS0 SPECIFICATIONS • HXWXD, INCHES 14.9"x13.2"x10.4" HxWxD,INCHES 0 p • HxW,(INCHES):24"x14.6" (INCHES)' (INCHES) 16.5°x13.4"x5.9" Q°°°°°�° �° •• WEIGHTRADOM(LBS) 2 WHITE • COLOR:(GRAY 73 _O O •®�O • COLOR:• WEIGHT(GRAY 46 IIIIIII I I !il!ii III 111111111®I III®IIIII0IIII,IIIIIIIII ® III J J I RENSEO/ISSUED FOR PERNIT JW 8/29/19 IIIIUIIUIIIIUIIIIIIUUIIIIUIIIIUUIIII - - O ISSUED FOR PERNIT JW 5/15/19 1111 Il 1111 II LLLJJI 1111 LLLJJI 1111 No. Sub.I.1 l Rev., App, Me BOTTOM BOTTOM Project Number: Drawn: 9(B Date:to/I]/Is 665003 Designed:Asw Date:to/I]/Is Checked: ndo Dale:10/17/18 ®ANTENNA DETAIL *ERICSSON RRUS-4449 DETAIL *ERICSSON RRUS-4415 DETAIL SCALE:NOT TO SCALE SCALE:NOT TO SCALE SCALE:NOT TO SCALE Project Title: CRAN_RUNY_STOG1 NODE 11 _ r 11: 1.3—.I NM10 -u u l--r✓.1 r 37 MARION AVE u� ,r uu`u L u °�+ . ./ I ° SARATOGA SPRINGS,NY 12866 "~f� +.I� +-��� 1_t LJ �J ,� Prepared For: �,—R.�_ fti.� I I L J r r Ll L L1 Lr'-ri.� 1��l LI L1. 'uA moi/ _t-a'r I„1...t Si' �u u u Li Li at&t ,I PROPOSED OMNI ANTENNA THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF AT&T AND MAY NOT BE REPRODUCED, r-'. DISSEMINATED OR REDISTRIBUTEDWITHOUT THE� 1. EXPRESS LVRITTEN CONSENT OF AT&T. z PROPOSED AMPHENOL ��� � _ Project Manager: POLE TOP MOUNTING .„. BRACKET(ie3X—MKS-01) rJ 1 K o TOP `• CENTERLINE EXISTING UTILITY POLE QF,11�1 CONNV NICATIO NS J r 95 Ryan Drive Suite 1 I Raynham,MA 02;67 Oh.,.0-0- ._... Office:781.713,4725-Fax:413-541-8158 4" 4 Drawing Scale: AS NOTED CD .M.I Date: 8129/19 1 II Drawing Title ■ I EQUIPMENT PERSPECTIVE VIEW FRONT SIDE DETAILS Drawing Number ANTENNA MOUNT DETAIL •SCHROFFTEOHAFDDD342_B EQUIPMENT SHROUD SCALE:NOT TO SCALE SCALE:NOT TO SCALE A-2 L i 'Prep4 (:)? Fa,,N: lb ared By: PROPOSED ANTENNA(TYP.) JUMPERS I ANTENNA MOUNT BRACKET ANTENNA CABLE— — (IT,Y,.PITCoAL2LV 120 MAX. 1 INFINIGY8 1033 Watervliet Shaker Rd Albany,NY 12205 1111 1 I =MIE Office#(518)690-0790 Fax#(518)690-0793 MI . • WEATHERPROOFING KIT --, 2 2 cl, (SEE NOTE 3) 2 2 c p SECONDARY POWER LINES 2 0 TO POLE CABLE GROUND NT * ''',4474414 * 2"UV RATED U—GUARD FOR ^-' FINISHED GRADE "/ 4161*, f; '' FIBER AND AISG CABLES 44.11111Iim. WEATHERHEAD(LEAVE 10' #6 AWG STRANDED COPPER GROUND CONDUCTORS FOR UTILITY ,.. • . l' —, , , .-- WIRE(GROUNDED TO GROUND BAR).SEE III" COMPANY TIE—INS) ,I., NOTE,2 F) 11,,:4 1 E FIBER 2 2 2 G__j CABLE CONNECTOR , CD (3)#6AWG WIRE IN 4,L 1-`?`'' 1-1/4"MIN.SCH.40 NOTES: 6 °71o9E) e UV RATED PVC CADWELD #2 AWG BARE SOLID TINNED 1.DO NOT INSTALL CABLE GROUND KIT AT A BEND AND FIBER DEMARC .— COPPER GROUND LEAD IN ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. G'PESSi(0'\' 1/2"UV RATED PVC 2.GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. sNAALIZIglEON AOFTE:ZTAZ AsTE'ANTD'AisLopc'AcLuifi; —— 1 JUMPERS ZPuENRD CRLoADD STEEL 5/8".8'-0"LONG 3.VMHZIZOKOFsl,N,IUHNA(Iiil:IET LT,Va—PART TAPE KIT, *TYPICAL GROUND ROD DETAIL *ANTENNA CABLE GROUND KIT FIBER IN 2”PVC CONDUIT(TYP) SCALE:N.T.S SCALE:AS NOTED P.ie...ber: Drawn: .. Data:WV. 665-003 2 2 Checked: Date:10/17/18 Project Title: AC POWER(TYP.)-----___ . #2 AWG COPPER GROUND(TYP.) CRAN_RUNY_STOG1 >-- 2 2 ANTENNA NODE 11 ENTRANCE RATED,NTAC3R 2 2 2 2 I NM10 PANEL WITH 100A-2P MCB COAX GROUND KITS #6 AWG SPLIT BOLT GROUND 37 MARION AVE 2 2 III ngIAggNCLOMNPNECTOR WITH SARATOGA SPRINGS,NY 12866 ArsHDR,EAPIRimmazycAT 'NNN..... 0 Ez_IGI2R0AuwNGD ciNospiDpEER,/2,, 1 X'OrjNil'OpIGOFTRpAOLE12,;1uAL SURGE ARRESTOR UV RATED PVC MI BONDING AND GROUNDING .40.11m.0..' 1R-CE,0 KuA rREETm,X,17 I C A 9 L E N ESC t101111..../ _....„---FO,PoPuENRD CRLoADD STEEL *IMM. at8ct METER MAIN WITH BYPASS /8".8'-0"LONG R RH(TYP.) THESED'UMEMI=EIVIETPROLTUnD, GENERAL WIRING DIAGRAM ,, /FOAMCIPVPRGEENI TC I ICODIjiN CC IRO:NWD I T H S'LMIETZMIT-C7==TTHE 1,4:, ANAUNNINO NRBAP 1W'PRAM *SCALE:N.T.S. j r!/r,1 gui.2R4LF3 it CoR0r:PFDNP DEp BR,o,ui6—FE,LC 1) LA CENTERLINE CENTERLINE % • AND SECURED WITH 5/8° 160 COMMUNICATIONS CLAMP COMPRESS.N CONNECTOR 9501Z::"7Zi74.7721.5!RFVZ-5=7 NOLDS:GRE#ANDWG BARE CONNECTORS(TYP.) e: AS NOTED CD Dat 8/29/19 la GROUNDING ONE LINE DIAGRAM UTILITY& SCALE:N.T.S GROUNDING DETAILS E-1 , . (16)PROPOSED AT&T OMNI TOP OF PROPOSED AT&T ANTENNAS ANTENNA MOUNTED ON , ELEVA TI0N±35.3 AGLA-2EXISTING WOOD UTILITY POLE CENTERLINE OF-PROPOSED AT&T ANTENNAS ELEVATION±34.3 AGL $TOP9IEXjSTINGIJjjj:L1YPOLE _ _ _ _ ELEVATION ±33.0' AGL ti i i 28" i i i i i EXISTING OVERHEAD PRIMARIES 0 i. ELEVATION ±30.0' AGL i i I EX/STING PR/MARY LINES TO i BE RELOCATED TO T-ARM i i EXISTING SECONDARY @ ±28.5' AGL i i i i i i i EXISTING SECONDARY LINE TO i BE RELOCATED 6'HIGHER i PROPOSED (3)#6 AWG JIVES i INSIDE PROPOSED (1) UV RATED i 1-1/4"MIN. SCH. 40 PVC CONDUIT i i i —' i i i i I i i i i i i i i i I i i i iii i i I i r ��� ,EXISTING FIBER @ ±19.49' AGL I i i EXISTING CATV @ ±18:71' AGL ii -- -- -- --- T i i i I i ii PROPOSED FIBER FROM EXISTING i i SOURCE(ROUTING TBD)IN i i PROPOSED 2"U-GUARD ©PROPOSED (1)AT&T EQUIPMENT ,N,t1 L L i PROPOSED FIBER DEMARC A-2 SHROUD WITH(1) RRUS 2205 �Ei��, i (B Y FIBER PROVIDER) AND (1)RRUS 8843 H H H i v�v�� i I PROPOSED FIBER JUMPERS T (FRONTHAUL &BACKHAUL) PROPOSED (1) 100A, 2 POLE i SERVICE ENTRANCE RATED, NEMA i 3R PANEL WITH 100A-2P MCB !- i I I PROPOSED METER MAIN WITH BYPASS(METER SHALL NOT j BE MOUNTED ON STREET SIDE) I i PROPOSED (1)#2 AWG COPPER GROUND IMRE INSIDE 1/2"UV RATED PVC CI Q 00 GRAPHIC SCALE: 4' 0 4' • • • • GROUND LEVEL i SCALE (8.5x1 1): 1" = 4'-O" /Project Number CRAN STOG 1 INFINIGY ' - -RU NY 665-003 1033 WATERVLIET SHAKER ROAD ALBANY,NY 12205 Drawing Number Ago i*I*411.71:..d°1.141111 ' at&t re. SARATOGA SPRINGS,NY 12866 L E 1 • CENTERLINE limo A ISSUED FOR CLIENT REVIEW BMM 08/29/2019 LEASE EXHIBIT No. Submittal/Revision By Date