Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20190844 Conley Solar Panels Application
CITY OF SARATOGA SPRINGS I i - DESIGN REVIEW COMMISSION 9 cri City Hall -474 Broadway r `}pry Saratoga Springs, New York 12866 Tel:518-587-3550 x25 15 fax:518-580-9480 www.saratoga-springs.org INSTRUCTIONS ARCHITECTURAL/ HISTORIC REVIEW APPLICATION I. ELIGIBILITY:An applicant to the Design Review Commission for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2. COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRC will on/y consider properly completed applications that contain 1 original and 1 digital version of the application and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!! 3. ACTIONS REQUIRING REVIEW: Architectural Review District Historic Review District • any exterior changes that require a building permit • Installation or exterior change to a structure requiring a • any change in exterior building materials building or demolition permit • a new, or change to an existing, sign or sign structure • any material change to exterior of a structure including: • demolition of a structure - addition or removal of exterior architectural features - installation, removal or material changes to exterior building elements such as roof, siding, windows, doors, Within a non-residential zoning district: • a change in exterior building color porches, etc. • installation of an awning - enclosure or screening or buildings openings such as windows, doors, porches, etc. - installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels,wind turbines, radio/satellite transmission/reception devices, etc. • Within a front yard setback: - installation, removal or material changes to drive- or walkways - installation or removal of architectural, sculptural or vegetative screening that exceeds 3' in height - installation of accessory utility structures or radio/satellite transmission/reception devices over 2' in diameter • a change in exterior building color within a non- residential zoning district • a new, or change to an existing, sign or awning • installation of telecommunications facilities Note— Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review. Revised 01/2019 4. DESIGN GUIDELINES: The Design Review Commission will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: • Height—consistent with historic form and context of site and surrounding properties • Scale— relationship of structure and its architectural elements to human size, form, perception • Proportion — relationship among building elements including front façade, windows, and doors • Rhythm — pattern resulting from repeating building elements such as door/window openings, columns, arches, and other façade elements • Directional Expression —compatibility with horizontal &vertical expression of surrounding structures • Massing & Open Space— relationship of structure to open space between it and adjoining buildings • Setback—compatibility with surrounding structures • Compatibility of the following with surrounding structures/properties: - Major building elements (storefronts, doors, windows, roof) - Building materials - Color— (in non-residential zoning districts only) 5. DECISIONS:The Design Review Commission may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of approval unless the project has sufficiently commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6. SUBMISSION DEADLINE: Check City's website (www.saratoga-springs.org) for application deadlines and meeting dates. 7. APPLICATION FEE: Make checks payable to the "Commissioner of Finance" and attach to top of original application. Fees are non-refundable. Demolition $350 Residential Structures (principal, accessory) $50 Residential approval —extension/modification $50 Non-residential/ mixed-use structures (principal) $500 Non-residential/mixed-use extension/modification $300 Non-residential/ mixed-use structures (sketch) $150 Non-residential signs, awnings, accessory structures $125 Non-residential approval —extension/modification $125 ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Commission responsibilities may be found in the City's Zoning Ordinance available in City Hall and on the City's web site at htte://www.sarato:a-serin:s.or: 544/Zonin:-Ordinance. Revised 01/2019 FOR OFFICE USE] Kr 0 G4 CITY OF SARATOGA SPRINGS i .�`• DESIGN REVIEW COMMISSION 9 ❑ (Application#) City Hall -474 Broadway Saratoga Springs, New York 12866 cbIRPoRA Tel:518-587-3550 x.5 15 fax:518-580-9480 (Date received) www.saratoga-springs.org ARCHITECTURAL/ HISTORIC REVIEW APPLICATION APPLICANT(S)* OWNER(S) (If not applicant) ATTORNEY/AGENT Name Kasselman Solar Bethanne & John Conley Address 20 Walker Way 290 Lake Ave. Albany, NY 12205 Saratoga Springs, NY 12886 Phone (518)703-0976/ Fax: (518) 953-1095 (518) 932-9011 / / Email scott.stevens@kasselmansolar.com Identify primary contact person: 0 Applicant 0 Owner 0 Attorney/Agent *An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant's interest in premises: 0 Owner 0 Lessee 0 Under option to lease or purchase PROPERTY INFORMATION Pro e Address Location: 290 Lake Ave Saratoga Springs, NY 12886 Tax Parcel #: 166 14 - 3 - 11 P rty l (for example: 165.52—4—37) Current ZoningDistrict: U R5 Property use: 0 Residential 0 Non-residential/mixed-use p �y / Type of Review: 0 Architectural 0 Historic 0 Extension/modification (of current approval) Summary description of proposed action: On behalf of homeowners, Bethanne &John Conley located at 290 Lake Ave Saratoga Springs, NY 12866, Kasselman Solar proposes to install 20 roof mounted solar panels on their detached garage. Has a previous application been filed with the DRC for this property? 0 No 0 Yes—date(s)? -App. No.(s)? Revised 01/2019 APPLICATION FEE (payable to "Commissioner of Finance"): Residential Structures (principal, accessory) $50 Non-residential/ mixed-use structures (principal) $500 Residential approval —extension/mod $50 Non-residential signs, awnings, accessory structures $125 Non-residential mixed-use sketch $150 Non-residential approval—extension/mod $125 Demolition $350 **A "complete" application consists of 1 hard copy(original) , and I electronic copy of application &ALL other materials as required below: New Construction /Additions O Color photographs showing site/exterior details of existing structures and adjacent properties O Site plan, drawn to scale, showing existing&proposed construction, property lines&dimensions, required &proposed setbacks&lot coverage, site features(fences,walks,trees, etc.); on no larger than 2'x3' sheet—smaller preferred if legible ❑ Elevation drawings showing design of all sides of existing&proposed construction—label dimensions, colors, materials, lighting(fixture &lamp type,wattage), etc. - include compass bearing&scale; no larger than 2'x3' sheet—smaller permitted if legible O Floor plans for proposed structure; on sheet no larger than 2'x3'—smaller permitted if legible O Product literature, specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color(in non-residential districts only) ❑ Color photographs showing site/exterior details of existing structures and that illustrate affected features ❑ Elevation drawings showing all sides of existing&proposed construction—label dimensions, colors, materials, lighting(fixture&lamp type,wattage), etc. -include compass bearing&scale; no larger than 2'x3'sheet—smaller permitted if legible ❑ Product literature,specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts only (Front setbacks:UR-I &INST-HTR=30';UR-4=25';UR-2,UR-3&NCUD-I=10') - Installation, removal or change in material of drive- and walkways - Installation or removal of architectural, sculptural or vegetative screening over 3' in height - Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2' diameter) For any of above: ❑ Color photographs showing site/exterior details of existing structures, and of adjacent properties ❑ Site plan showing existing&proposed construction: include property lines&dimensions, required&proposed setbacks&lot coverage, site features(fences,walks,trees, etc.) street names, compass bearing&scale; no larger than 2'x3' sheet—smaller preferred if legible ❑ Product literature,specifications and samples of proposed materials and colors She/Awnings ❑ Color photographs showing site/exterior details of existing structures, and adjacent properties ❑ Plan showing location of proposed sign/awning structure on building/premises: no larger than 11"x17" ❑ Scaled illustration of proposed sign/awning structure and lettering(front view&profile): include all dimensions of structure;type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware ❑ Descriptions,specifications of proposed lighting including fixture&lamp type,wattage, mounting method, and location ❑ Product literature,specifications and samples of proposed materials and colors Demolition ❑ Color photographs showing site/exterior details of existing structures, and of adjacent properties ❑ Site plan showing existing and any proposed structures- include dimensions, setbacks, street names, compass bearing, and scale ❑Written description of reasons for demolition and, in addition: ❑ For structures of"architectural/historical significance", demonstrate"good cause"why structure cannot be preserved ❑ For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a "contributing"structure in a National Register district(contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities ❑ Color photographs showing site/existing structures, and of adjacent properties ❑ Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale ❑ Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details ❑ Consult Article 240-12.22 of the City's Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 01/2019 Request for extension of current approval ❑ Identify date of original DRC approval: Current expiration date: Org.App. No. ❑ Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEQR Environmental Assessment Form ❑Applicants proposing the following must complete"Part I" of the SEQR Short Environmental Assessment Form (available here: http://www.dec.ny.gov/docs/permits_ej_operations_pdf/seafpartone.pdf): -Construction or expansion of a multi-family residential structure(4 units +) -Construction or expansion (exceeding 4,000 sq. ft.gross floor area) of a principal or accessory non-residential structure -Telecommunications facility, radio antennae,satellite dishes - Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? O No 0 Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification I/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Commission. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge,true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review of the Zoning Code of the City of Saratoga Springs. Date.. 8/1 9/2019 • r (applicant signature) Date: (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature: please see attached authorization form Date: Owner Signature: Date: Revised 01/2019 FOR OFFICE USE ONLY This application has been reviewed by the Zoning Enforcement Officer and is being forwarded to the Commission. Signature: Date: Additional Comments: Revised 01/2019 20 Walker Way kasselmansoLAR Colonie, NY 12205 (518)-478-8365 Fax: (518)-953-1095 John Conley This letter hereby authorizes Kasselman Solar LLC, to act as (customer) agent & contractor. I further authorize Kasselman Solar LLC, to submit my building permit application to the necessary town building department. • kCustomer Name (print) /ft. (0 Customer Signature • 4 r Customer Address ,c' L_ i 1 Town Sct - 1845.4' Kasselman Solar Employee Signature - AL; air wai= WESTSHORE DESIGN ENGINEERS, P.C. 100 GREAT OAKS BLVD. I SUITE 117A ALBANY I NEW YORK I 12203 To: Lindsey Halse Kasselman Solar 20 Walker Way Albany,NY 12205 Date: August 14, 2019 Ref.: 19080473 Subject: Conley Residence 290 Lake Rd. Saratoga Springs,NY To Whom It May Concern, The following references the structural roof analysis of the Conley residence located in Saratoga Springs, NY. Westshore Design Engineers has been retained in order to analyze the existing roof structure for adequacy in supporting the proposed additional loading due to rooftop solar panels. The site-specific loadings are as follows: Seismic Design Category B; basic Wind Speed of 130mph; and Ground Snow Load of 50psf, per ASCE 7-10. The existing roofs consist of 2x6 rafters at 20"on center with a 10' span. Applicable codes also include the 2017 NYS Uniform Supplement. Based on structural analysis, it has been determined that the R1 roof is adequate to support rooftop solar panels with a maximum loading of 4.3psf. "Unirac" L-foot anchors or equal with 5/16" diameter lags required at 48" on center maximum with 2.5" minimum embed or S-5! Clamps or equal for metal roofs. Please don't hesitate to contact us with additional requests. Thank you. Westshore Design Engineers of NEW SPS A , frQ, ti )• tc, 443 K �r�� 07/21 ;741i V" 7 - 09137.1 ESSIO 8-14-2019 John Eibert Nicolas Nitti, PE Director of Solar Operations President WestShore Design Engineers° 100 Great Oaks Blvd. II Suite 117A II Albany,NY 12203 II 518.313.7153 SOLARMOUNT END CONLEY RESIDENCE(GARAGE) I ENGINEER (N)E-MOUNT MOUNT OR MID LEGEND 04"THICK 9"x12" MOUNT AS REQ'D PER II Il II 290 LAKE RD.SARATOGA SPRINGS,NY ALUMINUM LG 320W SOLAR MODULE 20 LG 320 WATT SOLAR MODULES(65"X40"EA.)AND 20 MFGR. I I I I I ii ii ii SOLAREDGE P320 DC OPTIMIZERS ATTACHED TO RAILS IN 4 FLASHING (N)SOLAR PANEL LOCATIONS PER MANUFACTURER SPECIFICATIONS. �� (N)UNIRAC RAIL �o PV DESIGN ADHERES TO SECTION - UNIRAC SOLAR MOUNT RAIL SYSTEM RAILS ARE (E)ROOF SURFACE R234-SOLAR ENERGY SYSTEMS OF THE CENTERED UNDER PANEL SEAMS. li= 4.01- kassel man -- -_ - - ,ht K . - , MSP/AC DISCONNECT 19."- '- (INTERIOR WALL) 11- ‘61 Municipality: Ba re. ety2t,:osnLarnacietkoecgaoRsdrip,.reinygs .., Saratoga Springs,NY 12866 101 '------- —..** ' - . 3 lit ELECTRICAL SERVICE I ir ENTRY/METER .., Parcel ID:166.14-3-11 1 $ t ' ' ( II Installation Details:. SYSTEM SIZE:6.40 kW It RESIDENCE - , 20 LG NeON2 320W(LG320N1 K-A5)60-CELL 't. ill i • ilb MONO BLACK PV MODULES .- [LG 320 Dimensions:66.38"x 40"x 1.571 ' 20 SOLAREDGE P320 DC OPTIMIZERS f 'qi.. t„ [111111: I 1 SOLAREDGE 5.0 kW HD WAVE INVERTER o ' 41 UNIRAC SOLAR MOUNT RAIL SYSTEM 1 ' i - —---..i... dita 0 ..ir ," Roof Description:Detached;non habitable ini , R1/R2-SHINGLE WITH 26-DEGREE TILT II' RAFTER/TRUSS:20"o.c.(2"x 6") 410 t -1 I COLLAR TIES:40"o.c.(2"x 4") 1 ti - R1 AZIMUTH @ 270-DEGREES(W) . - . ;J. . IIIILN --,1. ..k. . R2 AZIMUTH @ 90-DEGREES(E) Install Notes:Trenching-86'from garage . 4 to house,20'interior run to panel. ... • iiiel.. A li 41111 Wants conduit for wires not direct burial. t w • 0 Is • 1 ' I - - 1 41.• - IF I I I 1 •' TRENCH PATH-86' • $ WITH 20'INTERIOR RUN t 1 _ _ , f - A .,..-. 1 k , - - eak 16- V i - it„-,..... . si --, a'. it Ali - . I . 4 ve'- :4' ., ,-, - If .. 111 • i . -41 ...I . 4 — / .1 • - - :7-. 47:-,."--,- ,-,-", -'--"---1 4 i N r itr , i /* , i i-e ..)1(... ir ii dr 13. ' ,... ,:. LEGEND „: a I 11 SOLAR MODULE WITH MICROINVERTER ' SETBACK NOTATIONS 1 i . Ng ' *ACCESSORY/DETACHED NON-HABITABLE: 11111111111 1111 1111 ,,,, Meets Exception 2 of Section R234 of the 41 .or I ti —' !I 11 2017 International Residential Building CodeAO ' and Errata amendments as adopted by NYS , • 1116,01 . _ .---. ,— - 1 -- (setbacks not required) . PV Design adheres to Section R234-Solar Energy Systems of the 2017 International Building Code&NYS Errata amendments as adopted by NYS Contains confidential,proprietary,and/or privileged information Customer: BETHANNE&JOHN CONLEY Address:290 LAKE AVE SARATOGA SPRINGS NY 12866 Phone: 518-932-9011 20 LG 320 W Modules 20 SolarEdge P 320 Power Optimizers 1 5k SolarEdge HD Wave Inverter 10 LG 320 W modules MSP 200 A Main 10 SolarEdge P 320 Power Optimizers 200 A Bus #10 PV Wire 5k vi _ -7 . . . Ei , 12 SolarEdge HD Wave Inverter 4/0 SEU inb I 3#8 AWG THHN , iiro— DC 1#10 GND 10 LG 320 W modules 1"Conduit 30A l"" 10 SolarEdge P 320 Power Optimizers . AC Utility:National Grid #10 PV Wire — 4#10 AWG THHN AC Disconnect not required Accl# 45276-14119 A 1#10 GND Backfed breaker dedicated to PV ONLY Meter#29864260 IZI • • • Z HZ 3/4"Conduit 1 Inverter 5k MSP Utility Meter Rate MPP Current 13.5 1. Turn off PV AC disconnect 1.Directory T,abel Rated MPP Voltage 380 prior to working inside 2.PV system equipped with Max System Voltage 480 panel rapid shutdown Max Circuit Current 30 2.Warning:Dual Power 3.Warning:This service meter Solaredge Power Optimizer Supply is also served by a PV system Rated DC Input Penner-320w 1.Warning-Electric Shock I Iazard-Do Sources:Utility grid and PV Maximum input Voltage-48 Vdc not touch terminals.Terminals on both Solar Electric System MPPT range-8 to 48 Vdc the line and load sides maybe energized 3.Solar Disconnect Max input current-13.75 Adc in the open position. Max output current-15 Adc 2.Solar Disconnect PV Modules Open circuit voltage-40.8 Vdc Maximum Power Voltage-33.3 Vdc Short circuit current-10.19 Adc Maximum Power current-9.62 Adc Kasselman Solar 20 Walker Way iK. kasselman Albany NY 12205 518-320-7669 ON® 2BIack 1101101111 60 LG325N1 K-A5 LG32ON1 K-A5 LG315N1 K-A5 325W I 320‘A'vvI 315W The LG NeON° 2 is LG's best selling solar module. It received the acclaimed 2015 Intersolar AWARD for featuring LG's Cello Technology that increases its power output and reliability making it one of the most powerful and versatile modules on the market. //i;. /r//!/ ....,„ • fl , / // / / APPROVED PRODUCT C uaMCSv /4,;,:.,1.,. /,),.:::',::::,,,:','",•%�/ ,- CE ,' ! / `� 1/`/ j/f it%�� //:',/,:,:::,:l: "_ KM 64573 BS EN 5115 Ph�tovoltac Modules -,',/, , ,/.; ',,,,J 7 . ihtertek /,! f/ / /f ✓//%f i/ /J/J•///�f•/ ` f �!f ''112'',////:',/:::/:/''':'/,'/ /1://;;;;/:'' ' ':'' ///':::':''''''''''1:•':7/// :','':::::',,://, /,':/;;:://:1',1:1/1';'/1/1/y *** USA- , , , ,, From ,06/ imported Parts / />>` ✓ /,� ;::;' f�/ I, , r//'/,./:,:///,''',/:"' ,;,:,';:1::I'„'' ,''''`,„;7 41,:,,/ � ;; r r i Features Enhanced Performance Warranty Enhanced Product Warranty LGNeON° Blackan nh n rf rm n Fp ° liffli eO ac has e aced pe o ace LG has extended the warranty of the NeON warranty. 2 to 25 years including labor,which is among After 25 years,LG NeON®2 Black is guaranteed the top industry standards. at least 86%of initial performance. + Aesthetic Roof Outstanding Durability LG NeON®2 Black has been designed with ' ;PiWith its newly reinforced frame design,LG has aesthetics in mind;thinner wires that appear extended the warranty of the NeON°2 Black all black at a distance.The product can increase for an additional 2 years.Additionally, the value of a property with its modern design. LG NeON®2 Black can endure a front load up to 6000 Pa,and a rear load up to 5400 Pa. Sin Better PerEformance on a Sunny Day Near Zero LID(Light Induced Degradation) T LG NeON®2 Black now performs better on a The n-type cells used in LG NeON®2 Black sunny days thanks to its improved temperature have almost no boron,which may cause the coefficient. initial performance degradation,leading to less LID. About LG Electronics LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels LG and energy storage systems.The company first embarked on a solar energy research program in 1985,supported by LG Group's vast experience in the semi-conductor,LCD,chemistry and materials industries.In 2010,LG Solar successfully released its first MonoX®series to the market,which is now available in 32 countries.The NeON®(previous.MonoX®NeON),NeON®2,NeON®2 BiFacial won the"Intersolar AWARD"in 2013,2015 and 2016,which demonstrates LG's leadership and innovation in the solar industry. ® *** Made inLG INIe0N2 Black *** usA*** � From Imported Parts LG325N1K-A5 LG320N1 K-A5 LG315N1K-A5 Mechanical Properties Electrical Properties(STC*) Cells 6 x 10 Model LG325N1K-A5 LG320N1 K-A5 LG315N1K-A5 Cell Vendor LG Maximum Power(Pmax) [W] 325 320 315 Cell Type Monocrystalline/N-type MPP Voltage(Vmpp) [V] 33.7 33.3 32.9 Cell Dimensions 161.7 x 161.7 mm/6 inches MPP Current(Impp) [A] 9.65 9.62 9.58 u of Busbar 12(Multi Wire Busbar) Open Circuit Voltage(Voc) [V] 40.9 40.8 40.7 Dimensions(L x W x H) 1,686 x 1,016 x 40 mm Short Circuit Current(1st) [A] 10.23 10.19 10.15 66.38 x 40 x 1.57 in Module Efficiency [%] 19.0 18.7 18.4 Front Load 6,000Pa/125 psf* Operating Temperature [°C] -40-+90 Rear Load 5,400Pa/113 psf* Maximum System Voltage [V] 1000(UL/IEC) Weight 18 kg/39.68 lb Maximum Series Fuse Rating [A] 20 Connector Type MC4(MC),PV-JM601 A(JMTHY) Power Tolerance [%] 0-+3 Junction Box IP68 with 3 Bypass Diodes *STC(Standard Test Condition):Irradiance 1000 W/m0,cell temperature 25°C,AM 1.5 Cables 1,000 mm x 2 ea/39.37 in x 2 ea The nameplate power output is measured and determined by LG Electronics at its sole and absolute Glass Tempered Glass with AR Coating discretion. Frame Anodized Aluminium *Please refer to the installation manual for the details. Electrical Properties(NOCT*) Model LG325N1K-A5 LG320N1 K-A5 LG315N1K-A5 Certifications and Warranty Maximum Power(Pmax) [W] 240 236 232 IEC 61215,IEC 61730-1/-2 MPP Voltage(Vmpp) [V] 31.2 30.8 30.4 UL 1703 MPP Current(Impp) [A] 7.69 7.67 7.63 Certifications IEC 61701(Salt mist corrosion test) Open Circuit Voltage(Voc) [V] 38.1 38.0 37.9 IEC 62716(Ammonia corrosion test) Short Circuit Current(Isc) [A] 8.23 8.20 8.17 ISO 9001 *NOCT(Nominal Operating Cell Temperature):Irradiance 800 W/mz,ambient temperature Module Fire Performance Type 2(UL 1703) 20°C,wind speed 1 m/s Fire Rating Class C(ULC/ORD C 1703,IEC 61730) Dimensions(mm/inch) Product Warranty 15 Years Output Warranty of Pmax Linear Warranty* *1)1st year.98%,2)After 1st year.0.5%p annual degradation,3)86%for 25 years12/os Temperature Characteristics NOCT [ °C] 45±3i ] Pmax [%/0C] -0.37 Voc [%/0C] -0.27 z9/,., -1 Isc [%/0C] 0.0 3 Frame Cross-section 1016/40 (Size of shortside) 976/38.4 P. Characteristic Curves (Distance between grounding&mounting holes) .175/6.9 04.3/0.2 40II/1II:6 H• Grounding holes(8ea) Q \ - -.. e - - / +, 1000W "' 10.,, - 8.5x12/0.3x0.5 Junction box N Mounting holes(8ea) u 800W o 6.0 F 600W 4.0 m 400W �� 1000/39.4 Cablelength v v 200W � s 2.0 rn I .c -^moomo v, v o i'c 0.0 10.0 20.0 30.0 40.0 Voltage(V) 0,N 3 o 0 U U N 9 9 v1 o Ul v 140 < a a o ix, 120 E Isc 100 ts Voc 0 80 vi7i Pm. r 60 e_ _ 40 - - f 0 0I I I I I Temperature(°C) / - - N -40 -25 0 25 50 75 90 *The distance between the center of the mounting/grounding holes. LG Electronics Inc. Product specifications are subject to change without notice. E■ P.1■� 0 LG Solar Business Division DS-N5-60-K-G-F-EN-80308 ; 2000 Millbrook Drive ©2019 LG Electronics.All rights reserved. Lincolnshire,IL 60069 E� � -Life's Good1 �+ www.lg-solarcom Power Optimizer 0 For North America P320 / P340 / P370 / P400 / P405 / P505 rri 25 YEAR WARRANTY 0 q0001, III III01, PVPoptimization at the module-level power Specifically designed to work with SolarEdge Fast installation with a single bolt inverters Next generation maintenance with module- Up to 25% more energy level monitoring Superior efficiency (99.5%) Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Mitigates all types of module mismatch losses, Shutdown System (PVRSS) from manufacturing tolerance to partial shading Module-level voltage shutdown for installer and firefighter safety Flexible system design for maximum space utilization solaredge.com • • w Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 P340 P370 P400 P505 Optimizer model P320 (for higher- P405 (typical module (for 60-cell (for high- power (for 72&96- (for thin film (for higher compatibility) modules) power 60-cell 60 and 72-cell cell modules) current modules) modules) modules) modules) INPUT Rated Input DC Power') 320 340 370 400 405 505 W Absolute Maximum Input Voltage 48 60 80 125,2) 83222 Vdc (Voc at lowest temperature) MPPT Operating Range 8-48 8-60 8-80 12.5-105 12.5-83 Vdc Maximum Short Circuit Current 11 10.1 14 Adc (Isc) Maximum DC Input Current 13.75 12.63 17.5 Adc Maximum Efficiency 99.5 Weighted Efficiency 98.8 98.6 Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1±0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System 1000 Vdc Voltage Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(W x L x H) 128 x 152 x 28/5 x 5.97 x 1.1 128x152x36/ 128x152x50/ 128x152x59/ mm/in 5 x 5.97 x 1.42 5 x 5.97 x 1.96 5 x 5.97 x 2.32 Weight(including cables) 630/1.4 750/1.7 845/1.9 1064/2.3 gr/lb Input Connector MC40) Output Wire Type/Connector Double Insulated;MC4 Output Wire Length 0.95/3.0 1.2/3.9 m/ft Input Wire Length 0.16/0.52 m/ft Operating Temperature Range -40-+85/-40-+185 °C/T Protection Rating IP68/NEMA6P Relative Humidity 0-100 (1)Rated STC power of the module.Module of up to+5%power tolerance allowed (2)NEC 2017 requires max input voltage be not more than 80V (3)For other connector types please contact SolarEdge PV System Design Using Single Phase Single phase Three Phase 208V Three Phase 480V a SolarEdge Inverter�4�(5) HD-Wave g P320,P340,P370, Minimum String Length P400 8 10 18 (Power Optimizers) P405/P505 6 8 14 Maximum String Length 25 25 50(6) (Power Optimizers) 5700(6000 with Maximum Power per String SE7600-US-SE11400- 5250 6000(7) 12750(8) W US) Parallel Strings of Different Lengths Yes or Orientations (4)For detailed string sizing information refer to:http://www.solaredge.com/sites/default/files/string_sizing_na.pdf (5)It is not allowed to mix P405/P505 with P320/P340/P370/P400 in one string (6)A string with more than 30 optimizers does not meet NEC rapid shutdown requirements;safety voltage will be above the 30V requirement (7)For SE14.4KUS/SE43.2KUS:It is allowed to install up to 6,500W per string when 3 strings are connected to the inverter(3 strings per unit for SE43.2KUS)and when the maximum power difference between the strings is up to 1,000W (8)For SE3OKUS/SE33.3KUS/SE66.6KUS/SE100KUS:It is allowed to install up to 15,000W per string when 3 strings are connected to the inverter(3 strings per unit for SE66.6KUS/SE100KUS) and when the maximum power difference between the strings is up to 2,000W ©SolarEdge Technologies Ltd.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc. (E Ro H S All other trademarks mentioned herein are trademarks of their respective owners.Date:12/2018/V01/ENG NAM.Subject to change without notice. S*ingle Phase Inverter with fid-Wave Technology for North America SE300OH-US / SE380OH-US / SE500OH-US / SE600OH-US/ SE760OH-US / SE1 OOOOH-US / SE1 140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 114000 VA Maximum DC Power @208V - 5100 - 3300 @ 208V - 5000 @ 208V - Transformer -less, Ungrounded Yes 17.7 x 14.6 x 6.8 / 450 x 370 x 174 Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 114000 VA 13.5 - - 3300 @ 208V Maximum Input Current @240V(2) 8.5 5000 @ 208V 13.5 16.5 20 27 30.5 Adc AC Output Voltage Min. -Nom. -Max. - 3 - 3 - - - Vac (183 - 208 - 229) 99.2 % CEC Weighted Efficiency 99 % Nighttime Power Consumption < 2.5 W AC Output Voltage Min. -Nom. -Max. 3 3 3 3 3 3 3 Vac (211 - 240 - 264) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety AC Frequency (Nominal) 59.3 - 60 - 60.50) Hz Maximum Continuous Output - 16 - 24 - - - A Current 208V Maximum Continuous Output Cur- 12.5 16 21 25 32 42 47.5 A rent @240V GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Yes Thresholds INPUT 3/4" minimum / 14-6 AWG 3/4" minimum /14-4 AWG Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 - 7750 - - - Transformer -less, Ungrounded Yes 17.7 x 14.6 x 6.8 / 450 x 370 x 174 Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V(2) - 9 - 13.5 - - - Maximum Input Current @240V(2) 8.5 10.5 13.5 16.5 20 27 30.5 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes -F / -C Ground -Fault Isolation Detection 600kQ Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(') Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL169913, CSA C22.2, Canadian AFCI according to TI.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG 3/4" minimum / 14-6 AWG 3/4" minimum /14-4 AWG Range DC Input Conduit Size / # of Strings / 3/4" minimum / 1-2 strings / 14-6 AWG 3/4" minimum / 1-3 strings / 14-6 AWG AWG Range Dimensions with Safety Switch 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / (HxWxD) mm Weight with Safety Switch 22110 25.1/11.4 26.2/11.9 38.8/17.6 Ib / kg Noise < 25 <50 dBA Cooling Natural Convection Natural convection Operating Temperature Range -13 to +140 / -25 to +60(4) (-40'F / -40'C option)(') -F / -C Protection Rating NEMA 4X (Inverter with Safety Switch) (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated (3) Revenue grade inverter P/N: SExxxxH-USOOONNC2 (4) For power de -rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf N -40 version P/N: SExxxxH-USOOONNU4 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2018/V01/ENG NAM. Subject to change without notice. CE RoHS SOLARMOUNT M:�UNIRAC SOLARMOUNT defined the standard in solar racking. Features are designed to get installers off the roof faster. Our grounding & bonding process eliminates copper wire and grounding straps to reduce costs. Systems can be configured with standard or light rail to meet your design requirements at the lowest cost possible. The superior aesthetics package provides a streamlined clean edge for enhanced curb appeal, with no special brackets required for installation. END Now Featuring: --Nm THE NEW FACE OF SOLAR RACKING Superior Aesthetics Package enphase E N E R G Y LOSE ALL OF THE COPPER & LUGS SMALL IS THE NEXT NEW BIG THING ENHANCED DESIGN & LAYOUT TOOLS System grounding through Enphase microinverters and trunk cables Light Rail is Fully Compatible with all SM Components Featuring Google Map Capabilities within U -Builder SOLARMOUNT OPTIMIZED COMPONENTS INTEGRATED BONDING & PRE -ASSEMBLED PARTS Components are pre -assembled and optimized to reduce installation steps and save labor time. Our new grounding & bonding process eliminates copper wire and grounding straps or bonding jumpers to reduce costs. Utilize the microinverter mount with a wire management clip for an easier installation. VERSATILITY ONE PRODUCT - MANY APPLICATIONS Quickly set modules flush to the roof or at a desired tilt angle. Change module orientation to portrait or landscape while securing a large variety of framed modules on flat, low slope or steep pitched roofs. Available in mill, clear and dark anodized finishes to outperform your projects financial and aesthetic aspirations. AUTOMATED DESIGN TOOL DESIGN PLATFORM AT YOUR SERVICE Creating a bill of materials is just a few clicks away with U -Builder, a powerful online tool that streamlines the process of designing a code compliant solar mounting system. Save time bycreating a user profile, and recall preferences and projects automatically when you log in. You will enjoy the ability to share projects with customers; there's no need to print results and send to a distributor, just click and share. in BONDING &GROUNDING N MECHANICAL LOADING E.AUL2703SYSTEM FIRE CLASSIFICATION NNNUNIRAC INTEGRATED BONDING SPLICE BAR INTEGRATED BONDING MIDCLAMP INTEGRATED BONDING L -FOOT w/ T -BOLT INTEGRATED BONDING MICROINVERTER MOUNT w/ WIRE MANAGEMENT UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT NVI UNMATCHED EXPERIENCE TECHNICAL SUPPORT 9 CERTIFIED QUALITY Unirac's technical support team is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheets greatly simplifies your permitting and project planning process. ENGINEERING EXCELLENCE BANKABLE WARRANTY CERTIFIED QUALITY PROVIDER Unirac is the only PV mounting vendor with ISO certifications for 9001:2015, 14001:2015 and OHSAS 18001:2007, which means we deliver the highest standards for fit, form, and function. These certifications demonstrate our excellence and commitment to first class business practices. a r DESIGN TOOLS BANKABLE WARRANTY PERMIT DOCUMENTATION Don't leave your project to chance, Unirac has the financial strength to back our products and reduce your risk. Have peace of mind knowing you are receiving products of exceptional quality. SOLARMOUNT is covered by a twenty five (25) year limited product warranty and a five (5) year limited finish warranty. PROTECT YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN PU62011FE628 -PRINTED