Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20190836 Child Time Signage Application
„TUG, .LEDE__atagy_s_EJ CM'OF SARAtTOGA, SPRINGS DESIGN REVIEW COMMISSION (Application#) - City Hall -474 Broadway Saratoga Springs, New York 12866 Tel 518-587-3550 x.515 fax 518-580-9480 (Date received) vArvw.saratoga-springs.org ARCHITECTURAL/ HISTORIC REVIEW APPLICATION APPLICANTOr OWNER(S) (If not applicant) ATTORNEY/AGENT Paul Kozlowski Bill Johnson N/A Name 4115 W. 90th Place 106 Reynolds Road Address Hometown, IL 60456 Ft. Edward, NY 12828 Phone 708-560-3628 / 518-225-3567 Email paulkoz@koznsc.com bill@stonegateracingstables.pom Identify primary contact person: RI Applicant 0 Owner 0 Attorney/Agent An applicant must be the property owner, lessee, or one with an option to lease or.purchase the property in question. Applicant's interest in premises: CI Owner Lessee 0 Under option to lease or purchase PROPERTY INFORMATION 7 Care Lane Tax Parcel #: N/A Property Address/Location: (for example:165.52—4—37) Current Zoning District: AR B Property use: 0 Residential M Non-residential/mixed-use Type of Review: I@ Architectural U Historic 0 Extension/modification(of current approval) Summary description of proposed action: 1, Paul Kozlowski, represent the new Lessee of the property, CHILDTIIVIE learning centers. We are looking to update the signage at this school. We would like to add a small building ID sign above the entrance along with goose neck down lighting. TV- Mil • • .r- • -111. - a' Y U -* I *. S .41 TY flood light facing the sign face. This monument sign will be designed to match the building and stay within the same size as the - - - - -- - - - - - - - Has a previous application been filed with the DRC for this property? IR No 0 Yes—date(s)? App. No.(s)? Revised 01/2019 Request for extension of current apprval O Identify date of original DRC approval: Current expiration date: Org.App. No. o Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEQR Environmental Assessment Form El Applicants proposing the following must complete"Part I"of the SEQR Short Environmental Assessment Form(available here: htt oyAos.sipermits eLoperations_pdfiseafpartone.pdf): -Construction or expansion of a multi-family residential structure(4 units ±) -Construction or expansion(exceeding 4,000 sq.ft.gross floor area)of a principal or accessory non-residential structure -Telecommunications facility, radio antennae,satellite dishes - Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest(as defined by General Municipal Law Section 809) in this application? • MI No 0 Yes- If yes, a statement disclosing the name, residence, nature,and extent of this interest must be filed with this application. Certification I/we,the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Commission. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is,to the best of my/our knowledge,true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review of the Zoning Code of the City of Saratoga Springs. 115-?-4 Date:8-6-1 9 (applica ignature) Date: (applicant signature) If applicant is not the currently the owner of the property,the current owner must also sign. APF 'Cr- 40 Owner Signature: Date: Owner Signature: Date: Revised 01/2019 OGA CITY OF SARATOGA SPRINGS r6' DESIGN REVIEW COMMISSION • City Hall-474 Broadway : Saratoga Springs, New York 12866 /A= 'FORA Tel:518-587-3550 x2515 fax:518-580-9480 vvww.saratoga-springs.org INSTRUCTIONS ARCHITECTURAL I HISTORIC REVIEW APPLICATION I. ELIGIBILITY:An applicant to the Design Review Commission for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2. COM-PLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRC will only consider properly completed applications that contain I ori flu. 1011, iiçiital version of the application and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!! 3. ACTIONS REQUIRING REVIEW: Architectural Review District Historic Review District • any exterior changes that require a building permit 0 Installation or exterior change to a structure requiring a 0 any change in exterior building materials building or demolition permit 0 a newor change to an existingsign or sign structure 0 any material change to exterior of a structure including: , , • demolition of a structure - addition or removal of exterior architectural features - installation, removal or material changes to exterior building elements such as roof, siding, windows, doors, Within a non-residential zoning district: 0 a change in exterior building color porches, etc. 0 installation of an awning -enclosure or screening or buildings openings such as windows, doors, porches, etc. - installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. •Within a front yard setback: - installation, removal or material changes to drive- or walkways - installation or removal of architectural, sculptural or vegetative screening that exceeds 3' in height - installation of accessory utility structures or radio/satellite transmission/reception devices over 2' in diameter o a change in exterior building color within a non- residential zoning district 0 a new, or change to an existing, sign or awning 0 installation of telecommunications facilities -- I Note—Ordinary maintenance or repair that does not involve a change in material, design or outer appearance I, is exempt from Historic or Architectural Review. Revised 01/2019 . DESIGN GUIDELINES: The Design Review Commission will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: • Height—consistent with historic form and context of site and surrounding properties • Scale— relationship of structure and its architectural elements to human size, form, perception • Proportion —relationship among building elements including front façade, windows, and doors • Rhythm—pattern resulting from repeating building elements such as door window openings, columns, arches, and other façade elements • Directional Expression—compatibility with horizontal &vertical expression of surrounding structures • Massing&Open Space—relationship of structure to open space between it and adjoining buildings • Setback—compatibility with surrounding structures • Compatibility of the following with surrounding structures/properties: Major building elements (storefronts, doors,windows, roof) Building materials - Color—((in non-residential zoning districts only) . DECISIONS:The Design Review Commission may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/quality of materials, manner of construction, and design, An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of approval unless the project has sufficiently commenced i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to extensions if requested before expiration date of prior approval. . SUBMISSION DEADLINE: Check City's website (vkAAANt.swratoga-sprir gss. r for application deadlines and meeting dates. 7. APPLICATION FEE: Make checks payable to the "commissioner of Finance" and attach to top of original application. Fees are non-refundable. Demolition $350 Residential Structures (principal, accessory) $50 Residential approval —extension/modification Non-residential mixed-use structures (principal) Non-residential/mixed-use e ten ion/ odific tion Non-residential mixed-use structures (sketch) $150 Non-residential signs, awnings, accessory structures $125 Non-residential approval—extension/modification $125 ADDITIONAL L I F R ATION: More detailed information on Architectural Review, Historic Review and the Design Review Commission responsibilities may be found in the City's Zoning Ordinance available in City Hall and on the City's web site at htt•: www.sarato.a-s.rin•s.or- 544 Zonin:-Ordinance. Revised 01/2019 APPLICATION FEE(payable to "Commissioner of Finance"): Residential Structures (principal,accessory) $50 Non-residential mixed-use structures (principal) $500 Residential approval—extension/mod $50 Non-residential signs,awnings, accessory structures $125 Non-residential mixed-use sketch $150 Non-residential approval—extension/mod $125 Demolition $350 "A "complete" application consists of I hard co. oni:hat and I electronic co ofapplication &ALL other materials as required below: New Construction/Additions ID Color photographs showing site/exterior details of existing structures and adjacent properties o Site plan,drawn to scale,showing existing&proposed construction, property lines&dimensions,required&proposed setbacks&lot coverage,site features(fences,walks,trees,etc.);on no larger than 2'x3'sheet—smaller preferred if legible El Elevation drawings showing design of all sides of existing&proposed construction—label dimensions,colors,materials,lighting(fixture &lamp type,wattage),etc.-include compass bearing&scale; no larger than 2'x3'sheet—smaller permitted if legible o Floor plans-for proposed structure;on sheet no larger than 2'x3'—smaller permitted if legible D Product literature,specifications and samples of proposed materials and colors Change in exterior building materials (windows,doors, roof, siding,etc.),or color(in non-residential districts only) O Color photographs showing site/exterior details of existing structures and that illustrate affected features o Elevation drawings showing all sides of existing&proposed construction—label dimensions,colors, materials, lighting(fixture&lamp type,wattage),etc.-include compass bearing&scale;no larger than 2'x3'sheet—smaller permitted if legible ID Product literature,specifications and samples of proposed materials and colors - - Within front yard setbacks in Historic Districts only (Front setbacks:UR-I &INST-HTR=30';UR-4=25';UR-2,UR-3&NCUD-I 10') - Installation, removal or change in material of drive-and walkways - Installation or removal of architectural, sculptural or vegetative screening over 3' in height - Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2'diameter) For any of above: O Color photographs showing site/exterior details of existing structures,and of adjacent properties El Site plan showing existing&proposed construction:include property lines&dimensions,required&proposed setbacks&lot coverage,site features(fences,walks,trees,etc.) street names,compass bearing&scale;no larger than 2'x3'sheet—smaller preferred if legible El Product literature,specifications and samples of proposed materials and colors Signage/Awnings Color photographs showing site/exterior details of existing structures,and adjacent properties NI Plan showing location of proposed sign/awning structure on building/premises: no larger than I I"x 17" • Scaled illustration of proposed sign/awning structure and lettering(front view&profile):include all dimensions of structure;type, dimensions and style of lettering or logo;description of colors, materials,mounting method and hardware M Descriptions,specifications of proposed lighting including fixture&lamp type,wattage, mounting method,and location • Product literature,specifications and samples of proposed materials and colors Demolition 0 Color photographs showing site/exterior details of existing structures,and of adjacent properties o Site plan showing existing and any proposed structures-include dimensions,setbacks,street names,compass bearing,and scale EI Written description of reasons for demolition and,in addition: O For structures of"architectural/historical significance",demonstrate"good cause"why structure cannot be preserved ID For structures in an architectural district that might be eligible for listing on National Register of Historic Places,or for a "contributing"structure in a National Register district(contact City staff), provide plans for site development following demolition- include a timetable and letter of credit for project completion Telecommunication facilities O Color photographs showing site/existing structures,and of adjacent properties o Site plan showing existing and proposed structures: include dimensions,setbacks,street names,compass bearing,and scale o Scaled illustration of proposed structures:include all dimensions; colors,materials,lighting,mounting details o Consult Article 240-12.22 of the City's Zoning Ordinance and City staff to ensure compliance with requirements for visual impact . assessment and existing and proposed vegetative screening Revised 01/2019 FOR OFFICE USE ONLY This application has been reviewed by the ZoniEnforcement Officer and is being forwarded to the Commission. Signature: Date:' __- __-- Additional Comments - ' ~ < _ - - _ _ _ - -. _ '- -_ ' -_____-__-'-- - - .. - _____- .�_ . _ - _ -_�___ Revised 01/2019 • 4 iire •• „P I%'t 4 ,011411.....-4—lril",.,,.... „,,r . • .A... .' 1 -.., . f Untitled Map - 4. ,-.,.?t , illi ' •, 4.1A114 ' ' —.-..?..''iai•.......). -- Legend • • .. _ '.'wexiligo*-- .,rite a description for your map. ," ' 4414; ... ..., .--. , .4-L - -,- .-..- . /01-1" 1 I' - 1-41. ' •ii, -4 1 ,- ig-..- • - _ . % '..-- ik .,i, , .. . . _ .4, : , , 4.. 41,. .. , ...• . ( _. „, , — L I 4 Ar- '. Isk. ''' r •.! •. • .. . 1( '1 1,-CP--.1..... • . _ • . - .._• , a , 11. *. ..'1' IIPS rkti, ' '11: ir,- . -''411. '*,''' ' ._,,li.... ', '.. . „AL'F r , --ir.,, p 4. !•. 1-..,. .. ,• AN i ,_, ..., ,, $ * .,.":- .,..- t. .,' '•'' ,, 'ill L • '.1*'• ' iii ii: i , t, iii ' , ' - -110411' 11". IL. %r .', .a. ir i ' . 'in •' .11• 7 , ` . •. ——t , •,, i....it; , . ,_. • ,,,, •. alf 4. ,i•-, it Al , • '' — ,...i. ,),Voliusdir.it 4,_ do ,.1. -litp.• L L .11. '.. . ..5'''' - ' '' —1-.* • 'Pk ' .ii 11.- . , . , rub ir -,,,,, ... L 4 . . • _, -,..-4,-,11•,........ ... _ ,. . m° ' •. . . . ., 4,11"..• r , • 16"" . - .. N. ...601, - . - 4E4 JUL ikh. -"'",,... . •-.-,,,. i.,...1. . - ...- ' - Ni• - - • - ,. ) •4 ....' - ' ' ' t p.•- -- .,...--- i - • r- Pi• -. - - • -,... - ° ilk, - _ , •.• - „LI., t . sr. . ..„.i , . o . . . . it r IP 411". * • m ' ....rik, ..' _ •a i P . , il. .. ... • j.'4 -' ir. l'''‘ .A ° "it . r 11_ .41. . . ' • 6.,1'.. •111 ....,-'...1-. ' 41., .'• '- . L _ ' .TP $44,, .. impiommimii7.0. _bile, .L.•IP.•i . 11, . — - •-L :g•a . . ..... _ ..., 41 ,-- • 40 41P _r, - . .•• -.. .i, -...•Pir a..-.1,W - .01.."-' ft - , - ti 41.ip. - ....• -,, -..„ 41:: .11 a - . ' . I,F.. • 114.41 "Walk -•. , - , - e .. ..., - •,,.. . • 10 41;!Ili , . . 4I • ..,_„4.-,.....,....... it ,...,_ 11P. 'di • ...i. .' 0 op ."1-....1. .1.'' • 4.- - ".3.•*,- c. .AL • , - ..,- .. 1 7,20i ac;c6,:iie 0ri ft A ' F,..EcHDTImE LEARNING CENTERS 1 5/F Non Illuminated Faux Sign CHILDTIME AND TAGLINE Raised copy and tagline BACKGROUND White BORDER Raised off the face- Painted Blue No existing signage „diallibb , 11,—.....-1 PIE ,k - 1, rr------=7 .....,._ CHILDTIME --,... --=-1 _---- , — — '',7"---- ' '41'?14- - •,:,....;7;Z:::, ,1, Z i l- ;' . . - -, 1 . . _ New Signage ADDRESS: FILE NAME: 0051 PAGE: 1/ V 0 n 0 7 Care Lane Saratoga Springs, NY 12866 DATE: 2/6/19 APPROV' NATIONAL SIGN CONTRACTOR 4115 W.90th Place . Hometown,Illinois 60456 7"-O" r_712" RAISED BORDER :u2 RAISED COPY C LDTIIVIE LEARNING CENTERS 'Lzri cJ END VIEW 2LANDSCAPING— 3"STEEL PIPE ALL AROUND BASE CONCRETE 12" 5/F Non Illuminated Faux Sign CHILDTIME AND TAGLINE Raised copy and tagline BACKGROUND White BORDER Raised off the face - Painted Blue BASE Faux Brick to match building brick color Remove existing sign • \\II\ .74 I I. 4:6 # CHILDTIME le A fri)flib IN .11 4! 1 Existing Signage New Signage ADDRESS: FILE NAME: 0051 PAGE: 2 CO 0 GI 7 Care Lane Saratoga Springs, NY 12866 DATE: 2/6/19 APPROVAL. NATIONAL SIGN CONTRACTOR 4115 W.90th Place Hometown,Illinois 60456 5'-6" 4" BOLTS PANEL • 1-FLUSH MOUNTED `� TO WALL TM LEARNING CENTERS BOLTS DETAIL S/F Non Illuminated Faux Sign CHILDTIME AND TAGLINE Raised copy and tagline BACKGROUND White BORDER Raised off the face- Painted Blue Note: Add 2 goose neck flood lights that come off the wall at least 2 feet. Exact style TBD. No existing signage 7F; ADD FLOOD LIGHTS CHILDTIME 11 ----- - il inum New Signage ADDRESS: FILE NAME: 0051 PAGE: 1 7 Care Lane 0 0 Saratoga Springs, NY 12866 DATE: 7/13/19 APPROVAL: NATIONAL SIGN CONTRACTOR 4115 W 90th Place Hometown,Illinois 60456 7'-0" 12" RAISED- BORDER .__ ,_ �, RAISED- - "' T COPY i� CFIILDTINIE TM LEARNING CENTERS _ a zo . ■ N • it, '1191 r: • i• :•,,71”111.--.1,-,_,,,.211/M1111. � -hl.• .. .4 •r"1Y" � • r r,a� , " I „� r °"%YY r1 1•- .� •-• v T f. T 1 - - A 4. 4 f.-y L� "',...:4"77,-.1i--It..,4......•!"-L.: .13,-,V,-;._ r1r7.. T.4 r .■ ;..^,.'Al,.tt. ..,� _...._11-..-71.--%.--2=-,P: .. '.1.---42:,,,f: � - �`. L''.I ; "� � S• •� i rI-t '-y.asW• .,'s-.- . .i-.f71i,rI'{h • �—., . rI -1 r•- :- .4 r ••:4�1#• + :I #.•I. '4r I f. iY ',.,..f, I 411 J a � •{•�• ; - - fir . — _ - • - .. t - A END VIEW FLOOD LIGHT ON FACE SIDE OF SIGN ONLY 3"STEEL PIPE 2'LANDSCAPING M ALL AROUND BASE CONCRETE 12" S/F Non Illuminated Faux Sign CHILDTIME AND TAGLINE Raised copy and tagline BACKGROUND White BORDER Raised off the face- Painted Blue BASE Faux Brick to match building brick color Note:Add flood light Remove existing sign - It ' P & • T G0 A ii II illin 9 in it CHILDTIME7 401.: . 7 _-4, , ' ''' ': 101, '---''' - -- ---- —. , R r. Existing Signage New Signage ADDRESS: FILE NAME: 0051 PAGE: 2 GO 0 0 7 Care Lane Saratoga Springs, NY 12866 DATE: 7/13/19 APPROVAL: NATIONAL SIGN CONTRACTOR 4115 W 90th Place • Hometown,Illinois 60456 FFLED18 RAB. Outdoor Project: Type: 11, -s, Prepared By: Date: 110 Driver Info LED Info Type Constant Current Watts 18.00W 120V 0.2A Color Temp 5000K(Cool) 208V 0.15A Color Accuracy 71 CRI Rectangular shaped LED floodlight designed to replace 70W Metal Halide.patent- 240V 0.13A L70 Lifespan 100,000 pending"Air-Flow"technology ensures long LED and driver lifespan.Use for building 277V 0.11A Lumens 2,429 façades lighting,sign lighting,LED landscape lighting and instant-on security lighting. Input Watts 19.70W Efficacy 123.3 LPW Color:Bronze Weight:5.7 lbs Efficiency 91% Technical Specifications Listings Note: Airflow: UL Listing: All values are typical(tolerance+/-10%) Airflow technology heat sink for superior cooling Suitable for wet locations.Suitable for ground LED Characteristics Ambient Temperature: mounting. Lifespan: Suitable For use in 40°C(104°F) IESNA LM-79&LM-80 Testing: 100,000-hour LED lifespan based on IES LM-80 Cold Weather Starting: RAB LED luminaires and LED components have results and TM-21 calculations Minimum starting temperature is-40°C(-40°F) been tested by an independent laboratory in LEDs: accordance with IESNA LM-79 and LM-80. Thermal Management Housing: DLC Listed: Multi-chip,high-output,long-life LEDs Die-cast aluminum housing,lens frame and This product is listed by Design Lights Consortium Color Consistency: mounting arm (DLC)as an ultra-efficient premium product that 7-step MacAdam Ellipse binning to achieve Mounting: qualifies for the highest tier of rebates from DLC consistent fixture-to-fixture color Heavy-duty mounting arm with"O"ring seal& Member Utilities.DLC Product Code: PVUWWHNV Color Stability: stainless steel screw Electrical LED color temperature is warrantied to shift no Driver: more than 200K in CCT over a 5-year period Constant Current,Class 2, 120-277V,50-60 Hz, Color Uniformity: 120V:0.2A,208V:0.15A,240V:0.13A,277V: RAB's range of CCT(Correlated Color 0.11A Temperature)follows the guidelines of the THD: American National Standard for(SSL)Products, ANSI C78.377-2017. 11.89%at 120V,17.78%at 277V Construction Power Factor: 98.7%at 120V,91%at 277V IP Rating: Surge Protection: Ingress Protection rating of IP66 for dust and water 6kV Need help?Tech help line:(888)722-1000 Email:custsery@rablighting.com Website:www.rablighting.com Copyright©2019 RAB Lighting All Rights Reserved Note:Specifications are subject to change at any time without notice Page 1 of 3 FFLED18 RAB. Outdoor Technical Specifications (continued) Construction Green Technology: Warranty: Reflector: Mercury and UV free.RoHS-compliant RAB warrants that our LED products will be free components. from defects in materials and workmanship for a Semi-specular anodized aluminum Optical period of five(5)years from the date of delivery to Gaskets: the end user,including coverage of light output, NEMA Type: color stability,driver performance and fixture finish. High-temperature silicone gaskets RAB's warranty is subject to all terms and Finish: NEMA Beam Spread of 7H x 6V conditions found at rablighting.com/warranty. Formulated for high durability and long-lasting color Other Patents: Equivalency: The FFLED design is protected by U.S. Pat. Equivalent to 100W Metal Halide D643,147,Canada Pat. 140798,China Pat. ZL201130171304.1,Mexico Pat.36757 and pending patent in Taiwan. Buy American Act Compliance: RAB values USA manufacturing!Upon request, RAB may be able to manufacture this product to be compliant with the Buy American Act(BAA).Please contact customer service to request a quote for the product to be made BAA compliant. Dimensions Features Ultra-efficient LED and optical design 5 If 1 $mm Replaces 70W MH floodlights 100,000-hour life based on LM-80 results and TM-21 calculations NEMA type-7H x 6V "Air-Flow"technology heatsink 5-Year,No-Compromise Warranty lArel 7" " 178 mm m Need help?Tech help line:(888)722-1000 Email:custsery@rablighting.com Website:www.rablighting.com Copyright©2019 RAB Lighting All Rights Reserved Note:Specifications are subject to change at any time without notice Page 2 of 3 FFLED18 RAB. Outdoor Ordering Matrix Family Wattage Mounting Color Temp NEMA Type Finish Driver Options Other Options FFLED 18 18=18W Blank=Swivel Blank=5000K Blank=7H x Blank= Blank=On/Off 1 Blank=No Option Blank=Standard 26=26W Arm (Cool) 6V Bronze /D10=0-10V /PC=120V USA=BAA 39=39W SF=Slipfitter N=4000K B55=5H x W=White Dimming Photocell Compliant 52=52W T=Trunnion (Neutral) 5V /480=480V On/Off /PC2=277V 80=80W Y=3000K B44=4H x 2 Photocell (Warm) 4V /E=120-277V /PCS=120V Swivel Battery Backup Photocell /EC=Cold Start /PCS2=277V Battery Backup Swivel Photocell /PCS4=480V Swivel Photocell /PCU=120-277V Button Photocell /MS=Mini Sensor /STL3=Stealth Sensor 1 Dimming Driver for 18W,26W&39W models only 2 Not available for 80W models Need help?Tech help line:(888)722-1000 Email:custsery@rablighting.com Website:www.rablighting.com Copyright©2019 RAB Lighting All Rights Reserved Note:Specifications are subject to change at any time without notice Page 3 of 3 I he choice is yours . . . ip.. _ _. ...,,,, ..,,, 1,,,,,. LIGHTINGiik 44,.. .... .). k_. , .,. Ai i , ,„ jk ifilik, il _, ._ . .. - - _ _ . 11:140111. __ . RABWEB.COM • 888722-1000 Individual components LED Heads Shades GNLED13 GSAC 13W LED Head 15" Angled Cone Shade GNLED26 26W LED Head fGSAC11 ngled Cone Shad (available in warm and neutral) GSAD 0 Gnv-vHviprkAr r ? 15" Angled Dome Shade GSAD 11 G1 i Gooseneck 24" Arm 11 „ Angled Dome Shade GOOSE2 GSST 4 Gooseneck 35" Arm 15" Straight Shade GSST11 11 " Straight Shade GOOSE3 Gooseneck 30" Arm Accessorief LRFGNLED Clear Lens & Reflector Kit w/Door Frame GOOSE4 Gooseneck 20" Arm 0 LFGNLED Frosted Lens & Door Frame Replacement GOOSE5 Gooseneck 20" Arm w/Pole Mount Ordering information Product Family Arm Wattage Color Temp Reflector Shade Color GN LED Blank No arm 13 13W N Neutral (4000K) Blank Flood reflector Blank No shade B Black 1 GOOSE1 26 26W Y Warm (3000K) + frosted lens AC 15" Angled cone W White 2 GOOSE2 S Spot reflector AC11 11 " Angled cone A Architectural Bronze 3 GOOSE3 + clear lens AD 15" Angled dome S Metallic Silver 4 GOOSE4 R Rectangular reflector AD11 11 " Angled dome G Hunter Green 5 GOOSE5 +clear lens ST 15" Straight shade YL Yellow ST11 11 " Straight shade R Red LB Light Blue BL Royal Blue BWN Brown Ivory Specifications UL Listing Suitable for wet locations. Suitable for mounting within 4' of the ground. LED Multi -chip, high -output, long -life LED Drivers 13W: Constant Current, Class 2,50/60 Hz, 100 - 240VAC: 0.3 - 0.15A, 277VAC: 0.15A, THD <20%, PF 97.5% 26W: Constant Current, Class 2,50/60 Hz, 0.48 A., THD <20%, PF 97.9% Angled Cone Shade, White Finish, Neutral Light Nominal Watts 13W 26W Input Watts @ 120V 15.4 28.9 Output Lumens* 705 1673 Lumens per Watt* 45.8 57.9 Color Accuracy (CRI)* 86 84 Correlated Color Temp. (Nominal CCT)* 4000K 4000K Cold Weather Starting Minimum starting temperature is -407 / -40°C Thermal Management Custom heat sink assembly in thermal contact with die-cast aluminum housing for superior heat sinking Housing Precision die-cast aluminum housing, lens frame and mounting plate Reflector Optional rectangular or spot reflectors available Gaskets High-temperature silicone Mounting Heavy-duty mounting arm with "O" ring seal & stainless steel screw Photometrics Three 13W LEDs at 15' Mounting Height 15' 15' GN1LED13NACW • Neutral Color Temp (4000K) 10' 10 • White Angled Cone Shade • Spaced 5' Apart •Tilted -200 5 Photometric Report #RAB00262 5' 0' 5' 10' 0, 15' 10' 5' 5' 0' 10' 5' 15' 10' Shades Angled Cone, Angled Dome or Straight Shade offered in both 11"and 15' Paint Finish Chip and fade resistant polyester powder coat finish. Offers significantly improved gloss retention and resistance to color change. Color Stability RAB LEDs exceed industry standards for chromatic stability Color Uniformity RAB's range of CCT (Correlated Color Temperature) follows the guidelines of the American National Standard for Specifications for the Chromaticity of Solid State Lighting (SSL) Products, ANSI C78.377-2011. IESNA LM -79 & LM -80 Testing RAB LED luminaires have been tested by an independent laboratory in accordance with IESNA LM -79 and LM -80, and have received the Department of Energy "Lighting Facts" label. California Title 24 Goosenecks comply with 2013 California Title 24 building and electrical codes as commercial, outdoor, non -pole -mounted fixtures < 30 Watts when used with a photosensor control. Select catalog number PCS900 (120\) or PCS900/277 to order a photosensor. Green Technology Mercury and UV free, and RoHS compliant. Powder coat finish formulated with an environmentally friendly, TGIC-free (Triglycidyl Isocyanurate) process. Patents The design of the GNLED is protected by patents pending in US, Canada, China, Taiwan and Mexico. * Please visit robweb.com for details on worm temperature performance. Three 26W LEDs at 15' Mounting Height 15' Grid Scales = 5'0" - Values shown in Footcandles 15' 10' GN1 LED26NACW • Neutral Color Temp (4000K) • White Angled Cone Shade • Spaced 5' Apart • Tilted -200 Photometric Report #RAB00206 15' 10' L I G H T I N G RABWEB.COM • 888 722-1000 Afforda bi I ity, Versatility. Now available in 80W. L� PREMIUM 5 wattages. beam spreads. nounting options. loodglihttamily RABLIGHTING.COM • 888 722-1000 FFLEID 0 •Replace 35W to 250W metal halide floods • Available in 18W, 26W, 39W, 52W and 80W • NEMA Type 7x6 beam spread (4x4 or 5x5 distributions also available*) • Ultra efficient: up to 112 lumens per Watt • Swivel arm, trunnion mount and slipfitter mount options* • 1 00,000 -Hour LED lifespan RAB's warranty is subject to all terms and conditions found at rablighting.com/Warranty Three mounting options: standard swivel arm, trunnion or slipfitter.* Three NEMA Types: 7x6, 5x5 and 44 for various beam spreads.* Patent -pending Air -Flow fins keep FFLEDs running cool. *Not available for 78W models. Dimensions and weight FFLE®18 STANDARD SWIVEL ARM Weight: 4.8 lbs. Weight: 12.5 lbs. 5" '-128 mm' I � 7" 178 mm V21 3" mm 7 1/2" 189 mm 1011 254 mr pvV ATT-HC)tj S 9 U 1"U 1 19 8 2 8 2 9 0 1 7 3 7 3 9 0 1 8 2 6, 5 4 6 5 4 8 2 7 3 7 6 5 4 9 a 6 5 4 a z 7 , 3 6 5 4 The FF LED family is ultra efficient, performing at up to 112 Im/W. OPTIONAL TRUNNION M01 INIT Weight: 14.2 lbs. 11.5" 292 mm 0 ®oo 11" 7 1/2" 279 mm 189 m m OPTIONAL SLIPFITTER MOUNT Weight: 14.2 lbs. 12.5" 318 mm E 7 1/2" 9 MM 189 mm Photometrics FRED 18W - 7H x 6V 15' Mounting Height, Aimed 300 Below Horizon Photometric Report #RAB01466 0 0 1 1 2 2 3 3 3 2 1 0 1 2 3 FRED 26W - 7H x 6V 15' Mounting Height, Aimed 300 Below Horizon Photometric Report #ITL82112 0 2 3 4 5 0 2 3 4 5 3 2 1 0 1 2 3 FRED 39W - 7H x 6V 15' Mounting Height, Aimed 300 Below Horizon Photometric Report #ITL79398 0 2 3 4 5 0 2 3 4 5 3 2 1 0 1 2 3 FRED 52W - 7H x 6V 15' Mounting Height, Aimed 300 Below Horizon Photometric Report #ITL82115 0 2 3 4 5 6 0 2 3 4 5 6 3 2 1 0 1 2 3 FRED 80W - 7H x 6V 15' Mounting Height, Aimed 300 Below Horizon Photometric Report #RAB01113 0 2 3 4 5 6 0 2 3 4 5 6 3 2 1 0 1 2 3 Mounting Height 8 10 12 15 18 20 Multiplier 3.5 2.3 1.6 1.0 0.7 0.6 Grid scales: Multiples of mounting height Values shown in footcandles FRED 26W - 5H x 5V 15' Mounting Height, Aimed 300 Below Horizon Photometric Report #ITL82214 0 2 3 4 5 0 2 3 4 5 3 2 1 0 1 2 3 FRED 39W - 5H x 5V 15' Mounting Height, Aimed 300 Below Horizon Photometric Report #ITL82217 0 2 3 4 5 0 2 3 4 5 3 2 1 0 1 2 3 FRED 52W - 5H x 5V 15' Mounting Height, Aimed 300 Below Horizon Photometric Report #ITL82220 0 2 3 4 5 6 0 2 3 4 5 6 3 2 1 0 1 2 3 FRED 80W - 5H x 5V 15' Mounting Height, Aimed 300 Below Horizon Photometric Report #RAB01092 0 2 3 4 5 6 0 2 3 4 5 6 3 2 1 0 1 2 3 FRED 26W - 4H x 4V 15' Mounting Height, Aimed 300 Below Horizon Photometric Report # ITL82232 0 2 3 4 5 0 2 3 4 5 3 2 1 0 1 2 3 FRED 39W - 4H x 4V 15' Mounting Height, Aimed 300 Below Horizon Photometric Report #ITL82235 0 2 3 4 5 0 2 3 4 5 3 2 1 0 1 2 3 FRED 52W - 4H x 4V 15' Mounting Height, Aimed 300 Below Horizon Photometric Report #ITL82238 0 2 3 4 5 6 0 2 3 4 5 6 3 2 1 0 1 2 3 FRED 80W - 4H x 4V 15' Mounting Height, Aimed 300 Below Horizon Photometric Report #RAB01090 0 2 3 4 5 6 0 2 3 4 5 6 3 2 1 0 1 2 3 FFLED' Specifications UL Listing: Suitable for wet locations. Suitable for ground mounting. LED: Multi -chip, high -output, long -life LEDs Lifespan: 100,000 -hour LED lifespan based on IES LM -80 results and TM -21 calculations Drivers: 18W: Constant Current, Class 2, 100-277V, 50/60 Hz, 6 kV surge protection, 120V: 0.17 A, 208V: 0.1 A, 240V: 0.09 A, 277V: 0.08 A 26W: Constant Current, Class 2, 100-277V, 50/60 Hz, 6 kV surge protection, 120V: 0.24 A, 208V: 0.15 A, 240V: 0.13 A, 277V: 0.11 A, 480V: 0.06 A 39W: Constant Current, Class 2, 100-277V, 50/60 Hz, 6 kV surge protection, 120V: 0.35 A, 208V: 0.20 A, 240V: 0.18 A, 277V: 0.15 A, 480V: 0.08 A 52W: Constant Current, Class 2, 100-277V, 50/60 Hz, 6 kV surge protection, 120V: 0.45 A, 208V: 0.27 A, 240V: 0.24 A, 277V: 0.21 A, 480V: 0.13 A 80W: Constant Current, Class 2, 100-277V, 50/60 Hz, 6 kV surge protection, 120V: 0.74 A, 208V: 0.48 A, 240V: 0.41 A, 277V: 0.36 A Equivalencies: 18W replaces 70W MH, 26W replaces 100W MH, 39W replaces 150W MH, 52W replaces 175W MH, 80W replaces 250W MH (based on 5000Kperformonce) 5000K Color Temperature Nominal Watts @120V 18W 26W 39W 52W 80W Input Watts* 20 29 42 54 89 Output Lumens* 2431 4087 5699 5496 9672 Lumens Per Watt* 123 143 136 102 109 Color Accuracy (CRI)* 71 75 75 67 72 4000K Color Temperature Nominal Watts @120V 18W 26W 39W 52W 80W Input Watts* 19 28 42 54 88 Output Lumens* 21 1 1 4043 5641 4536 9157 Lumens Per Watt* 109 143 134 84 104 Color Accuracy (CRI)* 71 75 75 82 72 3000K Color Temperature Nominal Watts @120V 18W 26W 39W 52W 80W Input Watts* 19 28 42 54 87 Output Lumens* 2064 3952 5518 4342 8591 Lumens Per Watt* 107 140 132 81 98 Color Accuracy (CRI)* 83 71 70 80 71 * Values shown for 7H x 6V NEMA Type only. Visit robweb.com for 5H x 5V and 4H x 4V performance. Ordering information Dimming: 18, 26, 39, 52 and 80W: Available as On/Off or with 0-10V dimming. Cold Weather Starting: The minimum starting temperature is -40°C. Thermal Management: Superior heat sinking with external Air -Flow fins Housing: Die-cast aluminum housing, lens frame and mounting arm Reflector: 18W: Semi -specular anodized aluminum, 26, 39, 52 and 80W: specular polycarbonate. NEMA Type: Standard 7H x 6V. 5H x 5V and 4H x 4V available for 26, 39, 52 and 80W models. Mounting: Heavy-duty mounting arm with "0" ring seal & stainless steel screws. Trunnion and slipfitter mounts also available for 26, 391 52 and 80W models. Gaskets: High-temperature silicone gaskets Finish: Our environmentally friendly polyester powder coatings are formulated for high -durability and long-lasting color, and contain no VOC or toxic heavy metals. Color Stability: LED color temperature warrantied not to shift more than 200K in CCT in 5 years Color Uniformity: RAB's range of CCT (Correlated Color Temperature) follows the guidelines of the American National Standard for Specifica- tions for the Chromaticity of Solid State Lighting (SSL) Products, ANSI C78.377-2015. Green Technology: Mercury and UV free, and RoHS compliant. Polyester powder coat finish formulated without the use of VOC or toxic heavy metals. IESNA LM -79 & LM -80 Testing: RAB LED luminaires have been tested in accordance with IESNA LM -79 and LM -80, and have received the Department of Energy "Lighting Facts" label. California Title 24: FFLED18 and FFLED26 equipped with a photocell comply with 2013 California Title 24 building and electrical codes as commercial outdoor non -pole -mounted fixtures <30 Watts. FFLED39, FFLED52 and FFLED80 equipped with a 0-10V driver comply with 2013 California Title 24 building and electrical codes as commercial outdoor non -pole -mounted fixtures >30 Watts mounted up to 24 feet when used with the RAB Stealth Dimmer. Use catalog code STLDIM10 to order a Stealth Dimmer module. *Values shown for 7H x 6V NEMA Type only. Visit robweb.com for 5H x 5V and 4H x 4V performance. Product Famil- `"'Rage Color Temp Finish urgency Options FLED 18 18 18W Blank 5000K Blank Bronze Blank 120-277Vac Blank No option N 4000K W White 0-10V Dimming /E* Emergency Battery Y 3000K 120-277 Vac Only /EC* Low Temp Emergency Battery available 120-277 Vac only Photocell Options Blank No option Blank No option /PCU 120-277Vac Button Photocell USA BAA Compliant /PCS 120 Vac Swivel Photocell /PCS2 277Vac Swivel Photocell /MS** Mini Sensor SMS500 /STL3** Stealth 360° Sensor Product Family Wattage Mounting Color Temp NEMA Type Finish Driver Options FLED 120V Swivel Photocell /PCS2 277V Swivel Photocell* /PCS4 480V Swivel Photocell 26 26W Blank Swivel arm Blank 5000K Blank 7H x 6V Blank Bronze Blank On/Off 39 39W SF Slipfitter N 4000K B55 5H x 5V W White /11310 0-10V Dimming 52 52W T Trunnion Y 3000K B44 4H x 4V /480 480V On/Off 80 80W *Available for 18W only. **Available for 18W only. Includes mounting plate CU4x CU4A =Bronze, CU4W = White Photocell Options Blank No Option /PC 120V Photocell /PC2 277V Photocell /PCS 120V Swivel Photocell /PCS2 277V Swivel Photocell* /PCS4 480V Swivel Photocell CCO dcoat sanded /styrene iedule 40 PVC Pipe el Pipe icrete =USTOM`�. AT ARC=, CT LTViL S IGnS, MM, ACCE NTS TECHNICAL DATA SHEET Expanded 1 lb Polystyrene Description Test Method Results Density, Minimum ASTM D303 1.15 Density, Range ASTM 1622 1.15-1.34 Thermal Conductivity @25F BTU ASTM C177 0.22 Thermal Conductivity @45F sq ft ASTM C177 0.235 Thermal Conductivity @75F F/in ASTM C177 0.255 Compression Strength ASTM D1621 13-18 Flexural Strength psi ASTM C203 30-38 Tensile Strength psi ASTM D1623 18-22 Shear psi ASTM D723 23-25 Water absorption by immersion ASTM C272 <4% Thermal Expansion, in/(in.)(F) ASTM D696 0.000035 Oxygen Index, min, volume % ASTM C578 24% Flame Spread ASTM E-84 20 Smoke Developed ASTM E-84 150-300 Termite Resistance ASTM D3345 (mod) Passed Carpenter Ant Resistance ASTM D3345 (mod) Passed Hard Coat na, 60 mils 1 lb Expanded Polystyrene Description ASTM Test 77 F 32 F Impact Resistance G14 500 IN-Ibs 350 IN-Ibs Elongation ASTM D412 400% 150@ Tensile Strength ASTM D412 3000 psi 2200 psi Tear Strength ASTM D624 250 pli 150 pli Flexibility ASTM D522 PASS PASS Fire Retardant ASTM E84 PASS PASS Synthetic Stucco Finish Description Test Method Results Freeze/Thaw ASTM C-67 No cracking, checking, crazing, erosion or other deleterious effects. Freeze/Thaw ICBO AC24 No cracking, checking, crazing, delaminatin , erosion or other deleterious effects. Water Resistance ASTM D2247-94 No cracking, checking, crazing, blistering, erosion, or other deleterious effects. Humidity Resistance ASTM D2247 No deleterious change in surface. Mold Resistance ASTMD3273-94 No growth of mold observed. Abrasion Resistance ASTM D-968-93 No cracking, checking or loss of film. Salt Spray ASTM B117-95 No cracking, crazing, blistering, erosion or deleterious effects. Accelerated Weatherin ASTM G-53 No surface changes such as cracking, checking, crazing or erosion. Accelerated Weathering ASTM G23-93 No surface changes such as cracking, checking, crazing or erosion. Fade Resistance ASTM D 1729-89 Passed