HomeMy WebLinkAbout20240752 76 Walton Second Floor Addition ApplicationRevised 01/2021
APPLICATION FOR:
ARCHITECTURAL / HISTORIC REVIEW
APPLICANT(S)* OWNER(S) (If not applicant) ATTORNEY/AGENT
Name
Address
Phone / / /
Email
Identify primary contact person: Applicant Owner Attorney/Agent
* An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question.
Applicant’s interest in premises: Owner Lessee Under option to lease or purchase
PROPERTY INFORMATION
Property Address/Location: Tax Parcel #: . - -
(for example: 165.52 – 4 – 37 )
Current Zoning District: Property use: Residential Non-residential/mixed-use
Type of Review: Architectural Historic Extension/modification (of current approval)
Summary description of proposed action:
Has a previous application been filed with the DRC for this property? No Yes – date(s)? _____________________
-App. No.(s)? _________________
Date Acquired by Owner: _________________
**HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED**
CITY OF SARATOGA SPRINGS
DESIGN REVIEW COMMISSION
CIT< +ALL %ROA':A<
6ARATO*A 6PRIN*6 N(: <OR.
T(L: ;
www.saratoga-springs.org
[FOR OFFICE USE]
_______________
ASSOicatiRn
____________
Date receiYed
@@@@@@@@@@@@@@@@@@@@@@@@@@
3rRMect TitlH
6taII RHYiHZ BBBBBBBBBBBBBBB
640 Johnson Spooner Road
Castleton Vt
William BergmanWilliam Bergman
billyb12308@yahoo.com
76 Walton St 165 51 1 26
UR-3
■
Renovation of current structure and new second floor addition atop current non-historical rear extension.
9177491360
10-5-23
**A “complete” application consists of 1 hard copy (original) , and 1 electronic copy of application & ALL other
materials as required below:
New Construction / Additions
Color photographs showing site/exterior details of existing structures and adjacent properties
Site plan, drawn to scale, showing existing & proposed construction, property lines & dimensions, required & proposed setbacks & lot
coverage, site features (fences, walks, trees, etc.); on no larger than 2’x3’ sheet – smaller preferred if legible
Elevation drawings showing design of all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture
& lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible
Floor plans for proposed structure; on sheet no larger than 2’x3’ – smaller permitted if legible
Product literature, specifications and samples of proposed materials and colors
Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only)
Color photographs showing site/exterior details of existing structures and that illustrate affected features
Elevation drawings showing all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp
type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible
Product literature, specifications and samples of proposed materials and colors
Within front yard setbacks in Historic Districts only (Front setbacks: UR-1 & INST-HTR=30’; UR-4=25’; UR-2, UR-3 & NCUD-1=10’)
-Installation, removal or change in material of drive- and walkways
-Installation or removal of architectural, sculptural or vegetative screening over 3’ in height
-Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2’ diameter)
For any of above:
Color photographs showing site/exterior details of existing structures, and of adjacent properties
Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot
coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2’x3’ sheet – smaller
preferred if legible
Product literature, specifications and samples of proposed materials and colors
Signage / Awnings
Color photographs showing site/exterior details of existing structures, and adjacent properties
Plan showing location of proposed sign/awning structure on building/premises: no larger than 11”x17”
Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type,
dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware
Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location
Product literature, specifications and samples of proposed materials and colors
Demolition
Color photographs showing site/exterior details of existing structures, and of adjacent properties
Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale
Written description of reasons for demolition and, in addition:
For structures of “architectural/historical significance”, demonstrate “good cause” why structure cannot be preserved
For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a
“contributing” structure in a National Register district (contact City staff), provide plans for site development following demolition -
include a timetable and letter of credit for project completion
Telecommunication facilities
Color photographs showing site/existing structures, and of adjacent properties
Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale
Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details
Consult Article 240-12.22 of the City’s Zoning Ordinance and City staff to ensure compliance with requirements for visual impact
assessment and existing and proposed vegetative screening
Revised 01/2021
Revised 01/2021
Request for extension of current approval
Identify date of original DRC approval: ______________Current expiration date: ________________ Org. App. No. ____________
Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood.
SEQR Environmental Assessment Form
Applicants proposing the following must complete “Part I” of the SEQR Short Environmental Assessment Form (available here:
http://www.dec.ny.gov/docs/permits_ej_operations_pdf/seafpartone.pdf):
-Construction or expansion of a multi-family residential structure (4 units +)
-Construction or expansion (exceeding 4,000 sq. ft. gross floor area) of a principal or accessory non-residential structure
-Telecommunications facility, radio antennae, satellite dishes
-Demolition
Disclosure
Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law
Section 809) in this application?
No Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this
application.
Certification
I/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance
before the Design Review Commission.
By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying
documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing
false or misleading information is grounds for immediate denial of this application.
I/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property
associated with this application for purposes of conducting any necessary site inspections relating to this application.
Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural
Review of the Zoning Code of the City of Saratoga Springs.
Date:
(applicant signature)
Date:
(applicant signature)
If applicant is not the currently the owner of the property, the current owner must also sign.
Owner Signature: Date:
Owner Signature: Date:
Revised 01/2021
INSTRUCTIONS
ARCHITECTURAL / HISTORIC REVIEW APPLICATION
1.ELIGIBILITY: An applicant to the Design Review Commission for Architectural Review or Historic Review
must be the property owner(s) or lessee, or have an option to lease or purchase the property in question.
2.COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is
complete. The DRC will only consider properly completed applications that contain 1 original and 1
digital version of the application and ALL other required materials as indicated on the application.
HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!!
3.ACTIONS REQUIRING REVIEW:
Architectural Review District Historic Review District
•any exterior changes that require a building permit
•any change in exterior building materials
•a new, or change to an existing, sign or sign structure
•demolition of a structure
Within a non-residential zoning district:
•a change in exterior building color
•installation of an awning
•Installation or exterior change to a structure requiring a
building or demolition permit
•any material change to exterior of a structure including:
-addition or removal of exterior architectural features
-installation, removal or material changes to exterior
building elements such as roof, siding, windows, doors,
porches, etc.
-enclosure or screening or buildings openings such as
windows, doors, porches, etc.
-installation of utility, mechanical or misc. accessory
structures to the exterior of a building such as HVAC
equipment, solar panels, wind turbines, radio/satellite
transmission/reception devices, etc.
Within a front yard setback:
-installation, removal or material changes to drive- or
walkways
-installation or removal of architectural, sculptural or
vegetative screening that exceeds 3’ in height
-installation of accessory utility structures or
radio/satellite transmission/reception devices over 2’ in
diameter
•a change in exterior building color within a non-
residential zoning district
•a new, or change to an existing, sign or awning
•installation of telecommunications facilities
Note – Ordinary maintenance or repair that does not involve a change in material, design or outer appearance
is exempt from Historic or Architectural Review.
CITY OF SARATOGA SPRINGS
DE SIGN REVIEW COMMISSION
City Hall - 474 Broadway
Saratoga Springs, New York 12866
Tel: 518-587-3550 x2533
www.saratoga-springs.org
4.DESIGN GUIDELINES:
The Design Review Commission will evaluate whether the proposed action (construction, alteration or
demolition) is compatible with existing structures and surrounding properties using the following criteria:
•Height – consistent with historic form and context of site and surrounding properties
•Scale – relationship of structure and its architectural elements to human size, form, perception
•Proportion – relationship among building elements including front façade, windows, and doors
•Rhythm – pattern resulting from repeating building elements such as door/window openings, columns,
arches, and other façade elements
•Directional Expression – compatibility with horizontal & vertical expression of surrounding structures
•Massing & Open Space – relationship of structure to open space between it and adjoining buildings
•Setback – compatibility with surrounding structures
•Compatibility of the following with surrounding structures/properties:
-Major building elements (storefronts, doors, windows, roof)
-Building materials
-Color – (in non-residential zoning districts only)
5.DECISIONS: The Design Review Commission may approve, approve with conditions, or disapprove an
application. The DRC may impose appropriate conditions and safeguards in connection with its approval
including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied
DRC application on the grounds of hardship.
Application approvals shall expire within 18 months of tIe filinH date unless the project has sufficiently
commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may
request up to 2 extensions if requested before expiration date of prior approval.
6.$GEND$ D$7E: Check City’s website (www.saratoga-springs.org) for meetinH dates "pplications are
placed on an aHenda on first-come, first-serWed Casis as determined CZ tIe completeness of tIe application
7.APPLICATION FEE N0N-3&'6N%"#-&
Make checks payable to the "Commissioner of Finance”
3&'&3 50 5)& $633&N5 '&& 803,4)&&5 *N$-6%&% *N 5)*4 %0$6.&N5
ADDITIONAL INFORMATION:
More detailed information on Architectural Review, Historic Review and the Design Review Commission
responsibilities may be found in the City’s Zoning Ordinance available in City Hall and on the City’s web site at
http://www.saratoga-springs.org/544/Zoning-Ordinance.
Revised 01/2021
Application to City Council FEE
Comprehensive Plan amendment $1,800 + $300/acre
Zoning Ordinance amendment $800 + $300/acre
Planned Unit Development (PUD) amendment $800 + $300/acre
Application to Zoning Board of Appeals
Use Variance $1,400 + $50/app
Area Variance - Residential $350/1st var +$50/app +$150/ea add variance
Area Variance - Non-residential $1000/1st var + $50/app+ $200/ ea add variance
Interpretations $650 + $50/app
Application Fee x 2 + $50/app
Variance extensions 50% of Application fee + $50/app
Application to Design Review Commission
Demolition $500
Residential Structures
Principal $70
Accessory $70
Extension $35
Modification $55
Multi-Family, Comm, Mixed-Use Structures
Sketch $200
Principal $650
Extension $250
Modification $400
Multi-Family, Comm, Mixed-Use Accessory, Signs, Awnings
Principal $150
Extension $100
Modification $150
Application Fee x 2
Application to Planning Board
Special Use Permit $1200 + $50/app
Temporary Use Permit $500
Special Use Permit - extension $400
Special Use Permit - modification $550 + $50/app
Site Plan Review - incl. PUD:
Sketch Plan $400 per sketch
Site Plan Full
Residential $400 + $250/unit
Non-residential $800 + $150/1000 sf
Administrative SPR
Residential $400
Non-residential $800
Extension
Residential $250
Non-residential $350
Subdivision - incl. PUD:
Sketch Plan $400 per sketch
Preliminary Approval
Residential: 1-5 lots $700 + $50/app
Residential: 6-10 lots $1100 + $50/app
Residential: 11-20 lots $1450 + $50/app
Residential: 21+ lots $1800 + $50/app
Residential - extension $350
Final Approval
Residential $1,550 + $200/lot + $50/app
Non- Residential $2,400/lot + $50/app
Final Approval Modification
Residential $400 + $50/app
Non- Residential $800 + $50/app
Final Approval Extension
Residential $250
Non- Residential $350
Other:
Lot Line Adjustment/Subdivision Administrative Action$400
Letter of Credit - modification or extension $400
Letter of Credit - collection up to 1% of LoC
Recreation Fee $2000/lot or unit
Land Disturbance $750 + $35/acre
Watercourse/Wetland Permit $750
SEQRA EIS Review (Draft & Final) TBD
Post Work Application Fee
Post Work Application Fee
OFFICE OF PLANNING AND ECONOMIC DEVELOPMENT FEES - 2023
City of Saratoga Springs
OPED Fees
Page 1 of 1
5
Scale
Project number
Date
devon telberg, aia
665 Saratoga Rd
Wilton, NY 12831
t (518) 212-7778
e devon@telbergstudio.com PROGRESS -NOT FOR CONSTRUCTI ON 8/12/2024 1:57:07 AMA000
Cover Sheet
2404
The Bergman Residence 8/11/24
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
LEVEL 3 ALTERATION RENOVATION
AND 2-STORY ADDITION
AT
76 WALTON DR.
SARATOGA SPRINGS, NY 12866
BERGMAN RESIDENCE
Sheet
Number Sheet Name
Current
Revision Date
A000 Cover Sheet 8/11/24
A010 Site Plan & Code Schedule 8/11/24
A100 Basement Removals & Proposed Plan 8/11/24
A101 First Floor Demolition & Proposed Plan 8/11/24
A102 Second Floor Removals & Framing Plan 8/11/24
A103 Attic Demolition & Proposed Plan 8/11/24
A104 Roof Removal, Framing and Proposed Plan 8/11/24
A200 Elevations 8/11/24
A300 Building Sections 8/11/24
A301 Building Section and Details 8/11/24
A303 Section at New Dormer and Stair 8/11/24
A500 Exterior Wall Details
No. Description Date
Progress 8/11/24
SD
SD
SD SD
SD
W D
SD
SD
SD
SD
SD
SD
W D
DNSD
SD
PL TO DORMER ROOF
3' - 0 1/2"
PL TO NEW ROOF
3' - 10 3/4"
10' - 0"
PL TO EXTG ROOF
2' - 5 1/4"NEW ADDITIONEXISTING TO REMAINEXISTING 2-STORY
GARAGE
EXISTING
SHED
EXISTING
CONCRETE
PAD
EXISTING
PAVEMENT
EXISTING REAR YARD
RE-SLOPE GRADE 1:2 MAX.EXISTING
2-STORY
BUILDING
NEW 1-STORY ADDITION
NEW 2-STORY ADDITION
WALTON STREET
RAILROAD ALLEY
NEW RETAINING WALLS
NEW PATIO
9' - 11 3/4"
9' - 0"
4' - 3 1/4"
2' - 5 1/2"NEW DORMER AT ROOFRE-GRADE SOIL AT
GRADUAL SLOPE 1:2 MAX
UNOCCUPIED
SPACE
199 SF
MECHANICAL ROOM
20
207 SF
PASSAGE
21
194 SF
GYM
22
202 SF
THEATER
23
49 SF
POWDER RM
25
421 SF
GAME ROOM
24
NOTE: EXISTING 1ST DWELLING UNIT
CONVERTED INTO SINGLE-FAMILY
DWELLING
171 SF
LOUNGE
16 77 SF
OFFICE
17
31 SF
POWDER RM 1
18
273 SF
LIVING
11203 SF
KITCHEN
13
428 SF
DINING
12
85 SF
PANTRY
14
68 SF
ENTRY
10
35 SF
PASSAGE 1
15
13 SF
CLOSET
10A
OPEN TO BELOW
R303.5.2 EXHAUST
AIR SHALL NOT BE
DIRECTED AT
WALKWAYS
TYPE X GWB AT LOCATIONS
THAT ARE 1HR FIRE-RATED
NOTE: EXISTING 2ND DWELLING UNIT
CONVERTED INTO SINGLE-FAMILY DWELLING
12 SFCL 228200 SF
PRIMARY BEDROOM
201
141 SF
PRIMARY BATHROOM
202
18 SF
WC 1
31
115 SF
PRIMARY CLOSET
203
161 SF
BEDROOM 3
209
66 SF
BATHROOM 3
210
145 SF
BEDROOM 2
206
24 SF
PASSAGE 2
204
12 SF
CL 3
205
58 SF
BATHROOM 2
20734 SF
LAUNDRY RM
208
217 SF
HALL
200
NOTE:EXISTING 3RD DWELLING UNIT
CONVERTED INTO SINGLE-FAMILY DWELLING
HABITABLE SPACE WITH
7'-6" CH: 78 SF
MINIMUM ROOM AREA
REQUIRED: 70 SF
26 SF
BATH
211
463 SF
GREAT ROOM
212
165 SF
BEDROOM 4
213
12 SF
CL 4
214
REQUIRED FLOOR AREA OF
ROOM ABOVE 5 FT HT: 137 SF
24" X 30" CLR
REQUIRED
GUARDRAIL MIN. 3'-6" HT,
WITHSTAND LOAD OF 200 LBS
UNOCCUPIED
SPACE
UNOCCUPIED
SPACE
HABITABLE SPACE
WITH 7'-6" CH: 20 SF
FLOOR AREA ABOVE
5 FT HT: 26 SF
3' - 10 3/4"
4' - 2 3/4"
2' - 5 1/2"
HABITABLE SPACE
WITH 7'-6" CH: 272 SF
FLOOR AREA ABOVE
5 FT HT: 352 SF
NOTE:EXISTING UNOCCUPIED
ATTIC CONVERTED INTO
OCCUPIED HABITABLE SPACE.
TABLE 302.1
EXTERIOR WALLS FIRE SEPARATION FROM PROPERTY LINE
WALLS
PROJECTIONS
OPENINGS
0 -5 FT
2 -5 FT
3 -5 FT
1 HOUR FIRE-RATED MIN.
1 HOUR FIRE-RATED MIN.
OR FIRE-RETARDANT-TRD WOOD
25% MAXIMUM OF WALL AREA: NON-RATED
EXCEPTION: THE FIRE-RESISTANCE RATING SHALL BE PERMITTED TO BE
REDUCED TO 0 HOURS ON THE UNDERSIDE OF THE EAVE OVERHANG IF
FIREBLOCKING IS PROVIDED FROM THE WALL TOP PLATE TO THE
UNDERSIDE OF THE ROOF SHEATHING.
R302.2.3 THE FIRE-RESISTANCE-RATED WALL SHALL BE CONTINUOUS FROM
THE FOUNDATION TO THE UNDERSIDE OF THE ROOF SHEATHING, DECK OR
SLAB. THE FIRE-RESISTANCE RATING SHALL EXTEND THE FULL LENGTH OF
THE WALL OR ASSEMBLY, INCLUDING WALL EXTENSIONS THROUGH AND
SEPARATING ATTACHED ENCLOSED ACCESSORY STRUCTURES.
R310.2.1 BASEMENT: ALL EMERGENCY ESCAPE AND RESCUE OPENINGS
SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQ.
FT.
1. GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM CLEAR OPENING OF
5.0 SQ. FT.
2. THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE NOT LESS THAN 24
INCHES
3. THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE NOT LESS THAN 20
INCHES
R314.1 SMOKE ALARMS AND HEAT DETECTION SHALL COMPLY WITH NFPA 72
AND SECTION R314.
R314.2.1 SMOKE ALARMS SHALL BE PROVIDED IN DWELLING UNITS.
R314.2.2 SMOKE ALARMS IN EXISTING BUILDINGS:EXISTING DWELLINGS
UNDERGOING REPAIR, ALTERATION, CHANGE OF OCCUPANCY, ADDITION OR
RELOCATION SHALL BE PROVIDED WITH SMOKE ALARMS AS REQUIRED BY
APPENDIX J.
R317.1 PROTECTION OF WOOD AND WOOD-BASED PRODUCTS FROM DECAY
SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS BY THE USE OF
NATURALLY DURABLE WOOD OR WOOD THAT IS PRESERVATIVE-TREATED IN
ACCORDANCE WITH AWPA U1.
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR
WHERE CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS WHERE
CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN
CRAWL SPACES OR UNEXCAVATED AREA LOCATED WITHIN THE
PERIPHERY OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY
EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8 INCHES (203
MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN
DIRECT CONTACT WITH THE GROUND UNLESS SEPARATED FROM
SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR
CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2 INCH (12.7
MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF
A BUILDING HAVING A CLEARANCE OF LESS THAN 6 INCHES (152 MM)
FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED
VERTICALLY FROM CONCRETE STEPS, PORCH SLABS, PATIO SLABS
AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE
FLOORS OR ROOFS THAT ARE EXPOSED TO THE WEATHER, SUCH AS
CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH
FLOORS OR ROOFS BY AN IMPERVIOUS MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS
ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY
WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN
APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL AND
THE FURRING STRIPS OR FRAMING MEMBERS.
R317.1.1 FIELD TREATMENT: FIELD-CUT ENDS, NOTCHES AND DRILLED HOLES
OF PRESERVATIVE-TREATED WOOD SHALL BE TREATED IN THE FIELD IN
ACCORDANCE WITH AWPA M4.
R317.3 FASTENERS AND CONNECTORS IN CONTACT WITH PRESERVATIVE-
TREATED AND FIRE-RETARDANT-TREATED WOOD: FASTENERS, INCLUDING
NUTS AND WASHERS, AND CONNECTORS IN CONTACT WITH PRESERVATIVE-
TREATED WOOD AND FIRE-RETARDANT-TREATED WOOD SHALL BE IN
ACCORDANCE WITH THIS SECTION. THE COATING WEIGHTS FOR ZINC-
COATED FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A153.
STAINLESS STEEL DRIVEN FASTENERS SHALL BE IN ACCORDANCE WITH THE
MATERIAL REQUIREMENTS OF ASTM F1667.
R317.3.1 FASTENERS FOR PRESERVATIVE-TREATED WOOD: FASTENERS,
INCLUDING NUTS AND WASHERS, FOR PRESERVATIVE-TREATED WOOD
SHALL BE OF HOT-DIPPED, ZINC-COATED GALVANIZED STEEL, STAINLESS
STEEL, SILICON BRONZE OR COPPER. STAPLES SHALL BE OF STAINLESS
STEEL. COATING TYPES AND WEIGHTS FOR CONNECTORS IN CONTACT WITH
PRESERVATIVE-TREATED WOOD SHALL BE IN ACCORDANCE WITH THE
CONNECTOR MANUFACTURER’S RECOMMENDATIONS. IN THE ABSENCE OF
MANUFACTURER’S RECOMMENDATIONS, NOT LESS THAN ASTM A653 TYPE
G185 ZINC-COATED GALVANIZED STEEL, OR EQUIVALENT, SHALL BE USED.
EXCEPTIONS:
1. 1/2-INCH-DIAMETER (12.7 MM) OR GREATER STEEL BOLTS.
2. FASTENERS OTHER THAN NAILS, STAPLES AND TIMBER RIVETS SHALL
BE PERMITTED TO BE OF MECHANICALLY DEPOSITED ZINC-COATED
STEEL WITH COATING WEIGHTS IN ACCORDANCE WITH ASTM B695,
CLASS 55 MINIMUM.
3. PLAIN CARBON STEEL FASTENERS IN SBX/DOT AND ZINC BORATE
PRESERVATIVE-TREATED WOOD IN AN INTERIOR, DRY ENVIRONMENT
SHALL BE PERMITTED.
CONSTRUCTION TYPE:
EXISTING: TYPE VB
PRIMARY STRUCTURAL FRAME: NON-RATED
BEARING WALLS:
EXTERIOR:NON-RATED
INTERIOR: NON-RATED
NON-BEARING WALLS:
EXTERIOR:1HR (0-30 FT)
INTERIOR:NON-RATED
FLOORS:NON-RATED
ROOFS:NON-RATED
NEW ADDITION:TYPE VB
PRIMARY STRUCTURAL FRAME: NON-RATED
BEARING WALLS:
EXTERIOR:NON-RATED
INTERIOR: NON-RATED
NON-BEARING WALLS:
EXTERIOR:1HR (0-30 FT)
INTERIOR:NON-RATED
FLOORS:NON-RATED
ROOFS:NON-RATED
TYPE OF ALTERATION:LEVEL 3 -WORK AREA ENTIRE BUILDING
TYPE OF WORK BEING PERFORMED:RENOVATION & ADDITION
FIRE-TREATED WOOD:
REQUIRED: AT LOCATIONS WITHIN 5 FT OF PROPERTY LINE.
SEE FIRE BLOCKING NOTES AND FRAMING PLAN NOTES.
SPRINKLERS:
NOT REQUIRED, EXCEPTION MONITORED FIRE ALARM SYSTEM
FLOOD HAZARD AREA:NO
METHOD OF COMPLIANCE:
ENERGY CODE: PRESCRIPTIVE
ASHRAE 90.1: PRESCRIPTIVE
EBC502.1 ALLOWABLE STORY, AREA & HEIGHT
EXISTING WITH ADDITION PROVIDED:
ALLOWABLE STORIES
ALLOWABLE HEIGHT 55 FT 65 FT
BASEMENT
FIRST FLOOR
SECOND FLOOR
ATTIC FLOOR
TOTAL:
EXISTING
1,120 SF
1,128 SF
1,128 SF
0 SF
3,376 SF
PROPOSED
485 SF
470 SF
306 SF
515 SF
1,776 SF
SUBTOTAL
1,605 SF
1,598 SF
1,434 SF
515 SF
5,152 SF
AJ801.3.3 PROVIDE A FIRE ALARM SYSTEM IN COMPLIANCE WITH SECTION
R314.7 AND MONITORED BY AN APPROVED SUPERVISING STATION IN
ACCORDANCE WITH NFPA 72 THROUGHOUT THE ENTIRE BUILDING.
(EXCEPTION #3)
AJ901.5 COMPLY WITH FIRE AND LIFE SAFETY PROTECTIONS FOR A HISTORIC
BUILDING. SMOKE ALARMS MUST BE INTERCONNECTED AND HARD WIRED.
PROVIDE MARBON MONOXIDE ALARMS THROUGHOUT.
ARCHITECTURAL GENERAL NOTES:
1. WRITTEN DIMENSIONS HAVE PRECEDENCE OVER SCALED
DIMENSIONS. THE CONTRACTOR SHALL USE CAUTION WHEN SCALING
REPRODUCED PLANS. IN THE CASE OF A CONFLICT BETWEEN THIS
PLAN SET AND ANY OTHER DRAWING, DETAIL, OR SPECIFICATION THE
ARCHITECT SHALL BE NOTIFIED IMMEDIATELY FOR CLARIFICATION.
2. ALL CONSTRUCTION IS TO COMPLY TO RESIDENTIAL CODE (2020) &
LOCAL CODES. NEW YORK STATE 2020 UNIFORM CODE SUPPLEMENT.
3. ALL DIMENSIONS FROM EXT. SHEATHING TO FINISHED DRYWALL
4. CONC. CONTRACTOR TO BE RESPONSIBLE FOR ALL CONC. CUTTING &
REMOVAL.
5. THE CONTRACTOR SHALL VERIFY EXISTING AND FIELD CONDITIONS.
THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY
DISCREPANCIES OR REQUIRED MODIFICATIONS PRIOR TO
COMMENCING INSTALLATION OF EQUIPMENT AND ASSOCIATED WORK.
6. PROVIDE DOUBLE STUDS AT JAMBS OF ALL DOORS, WINDOWS AND
SIMILAR OPENINGS.
7. ADJACENT AREAS AND/OR PORTIONS OF THE WORK AREA ARE OWNER
OCCUPIED AND OPERATE FULL TIMES TWENTY FOUR (24) HOURS A
DAY AND SEVEN (7) DAYS A WEEK. THE WORK SHALL BE
COORDINATED TO ALLOW OWNER ACCESS ADJACENT TO AND
AROUND THE PROJECT SPECIFIC AREAS AT ALL TIMES UNLESS
SPECIFICALLY PERMITTED IN ADVANCE BY THE OWNER.
8. SPECIAL PROTECTION AND SEPARATION IS REQUIRED FOR WORK
ADJACENT TO OCCUPIED SPACES. AIR BARRIERS, AIR SEPARATION,
AND OTHER PROTECTION SHALL BE REQUIRED TO SEPARATE WORK
FROM ALL OWNER OCCUPIED AREAS. PROTECTION SHALL BE
REQUIRED TO RESIST IMPACT BY OWNER TRAFFIC; CONTRACTOR
SHALL BE RESPONSIBLE FOR COORDINATING IMPACT REQUIREMENTS
WITH OWNER'S REPRESENTATIVE. ALL PROTECTION SHALL BE
SUBJECT TO REVIEW AND APPROVAL BY THE OWNER AND ARCHITECT.
9. SPECIAL NOISE CONTROL AND/OR LIMITED HOURS FOR WORK
REQUIRING NOISE AND/OR VIBRATION SHALL BE REQUIRED FOR WORK
IN, ADJACENT TO AND ABOVE OR BELOW OCCUPIED SPACES,
INCLUDING BUT NOT LIMITED TO ANY WORK THAT MAY TRANSMIT
SOUND OR VIBRATION TO OWNER OCCUPIED SPACES. ALL
SCHEDULING FOR WORK PRODUCING NOISE SHALL BE SUBJECT TO
APPROVAL BY THE OWNER.
10. PROVIDE 1/2 INCH GYPSUM WALL BOARD ON INTERIOR WALLS AND
CEILINGS.
11. PROVIDE 1/2 INCH TYPE-X FIRERATED GYPSUM BOARD ON INSIDE OF
FIRE-RATED EXTERIOR WALLS.
12. PROVIDE 1/2 INCH WATER RESISTANT GYPSUM BOARD AROUND
TUBS, SHOWERS AND WHIRLPOOLS.
13. GRADE MUST DROP 6 INCHES THE FIRST 10 FEET OF GRADE FROM
HOUSE FOUNDATION
FIRE BLOCKING NOTES:
1. PROVIDE FIREBLOCKING AT ALL LOCATIONS REQUIRED BY CODE
SECTION 602.8.
2. FIREBLOCK SECOND FLOOR JOISTS SO THAT NO HORIZONTAL RUN
EXCEED 20'-0" TYPICAL.
3. FIREBLOCK STAIRWELL ALONG STRINGERS.
4. FIREBLOCK WALLS WHERE THE VERTICAL CONCEALED SPACE
EXCEEDS 8 FEET VERTICALLY. VERTICAL CONCEALED SPACES ARE
NOT TO EXCEED 8 FEET VERTICALLY TYPICAL.
5. FIREBLOCK ALL WALLS WHERE A SOFFIT IS CONSTRUCTED AT THE
SOFFIT LEVEL.
6. FIREBLOCK AT BEARING WALL AND GIRDER LOCATION.
R308 SAFETY GLAZING NOTES:
1. GLAZING REQUIRED IN SIDE-HINGED DOORS EXCEPT JALOUSIES.
2. GLAZING REQUIRED IN FIXED AND SLIDING PANELS OF SLIDING DOOR
ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR
ASSEMBLIES.
3. GLAZING REQUIRED IN STORM DOORS.
4. GLAZING REQUIRED IN ALL UNFRAMED SWINGING DOORS.
5. GLAZING REQUIRED IN DOORS AND ENCLOSURES FOR HOT TUBS,
WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS.
GLAZING IN ANY PART OF A BUILDING WALL ENCLOSING THESE
COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE MEASURES
VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE.
6. GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO
A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24-INCH
ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE
IS LESS THAN 60 INCHES OF THE GLAZING IS LESS THAN 60 INCHES
ABOVE THE FLOOR OR WALKING SURFACE.
7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN
THOSE LOCATIONS DESCRIBED IN ITEMS 5 AND 6 ABOVE, THAT MEETS
ALL OF THE FOLLOWING CONDITIONS:
A. EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE
FEET.
B. BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR.
C. TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR.
D. ONE OR MORE WALKING SURFACES WITHIN 36 INCHES
HORIZONTALLY OF THE GLAZING.
8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT
ABOVE A WALKING SURFACE. INCLUDED ARE STRUCTURAL BALUSTER
PANELS AND NONSTRUCTURAL IN-FILL PANELS.
9. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR
SWIMMING POOLS, HOT TUBS, SHOWERS, BATHTUBS AND SPAS
WHERE THE BOTTOM EDGE OF THE POOL OR SPA SIDE IS LESS THAN
60 INCHES ABOVE A WALKING SURFACE AND WITHIN 60 INCHES
HORIZONTALLY OF THE WATER'S EDGE. THIS SHALL APPLY TO SINGLE
GLAZING AND ALL PANES IN MULTIPLE GLAZING.
10. GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36
INCHES HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED
SURFACE OF THE GLASS IS LESS THAN 60 INCHES ABOVE THE PLANE
OF THE ADJACENT WALKING SURFACE.
11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES
HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY
DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS
THAN 60 INCHES ABOVE THE NOSE OF THE TREAD.
WOOD PROTECTION NOTES:
1. PROTECTION OF WOOD AND WOOD-BASED PRODUCTS FROM DECAY
SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS BY THE USE OF
NATURALLY DURABLE WOOD OR WOOD THAT IS PRESERVATIVE-
TREATED IN ACCORDANCE WITH AWPA U1.
A. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR
WHERE CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS
WHERE CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED
GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED
WITHIN THE PERIPHERY OF THE BUILDING FOUNDATION.
B. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR
MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8
INCHES (203 MM) FROM THE EXPOSED GROUND.
C. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT
IS IN DIRECT CONTACT WITH THE GROUND UNLESS SEPARATED
FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
D. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR
CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2 INCH
(12.7 MM) ON TOPS, SIDES AND ENDS.
E. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR
OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6 INCHES
(152 MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM)
MEASURED VERTICALLY FROM CONCRETE STEPS, PORCH SLABS,
PATIO SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO
THE WEATHER.
F. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-
PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE
WEATHER, SUCH AS CONCRETE OR MASONRY SLABS, UNLESS
SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS
MOISTURE BARRIER.
G. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS
ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY
WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN
APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL
AND THE FURRING STRIPS OR FRAMING MEMBERS.
EBC901.2 & EBC801.3 ALTERATIONS LEVEL 2 COMPLIANCE
NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
SHALL COMPLY WITH THE REQUIREMENTS OF THE BUILDING CODE OF NEW
YORK STATE.
EXCEPTIONS:
1. WHERE WINDOWS ARE ADDED THEY ARE NOT REQUIRED TO
COMPLY WITH THE LIGHT AND VENTILATION REQUIREMENTS OF THE
BUILDING CODE OF NEW YORK STATE.
2. NEWLY INSTALLED ELECTRICAL EQUIPMENT SHALL COMPLY WITH
THE REQUIREMENTS OF SECTION 807.
3. THE LENGTH OF DEAD-END CORRIDORS IN NEWLY CONSTRUCTED
SPACES SHALL ONLY BE REQUIRED TO COMPLY WITH THE
PROVISIONS OF SECTION 805.6.
4. THE MINIMUM CEILING HEIGHT OF THE NEWLY CREATED HABITABLE
AND OCCUPIABLE SPACES AND CORRIDORS SHALL BE 7 FEET (2134
MM).
EBC1501.2 STORAGE AND PLACEMENT.
CONSTRUCTION EQUIPMENT AND MATERIALS SHALL BE STORED AND
PLACED SO AS NOT TO ENDANGER THE PUBLIC, THE WORKERS OR
ADJOINING PROPERTY FOR THE DURATION OF THE CONSTRUCTION
PROJECT.
APPS
EBC1501.3 ALTERATIONS, REPAIRS AND ADDITIONS.
REQUIRED EXITS, EXISTING STRUCTURAL ELEMENTS, FIRE PROTECTION
DEVICES AND SANITARY SAFEGUARDS SHALL BE MAINTAINED AT ALL
TIMES DURING ALTERATIONS, REPAIRS OR ADDITIONS TO ANY BUILDING
OR STRUCTURE.
EBC1501.4 MANNER OF REMOVAL.
WASTE MATERIALS SHALL BE REMOVED IN A MANNER THAT PREVENTS
INJURY OR DAMAGE TO PERSONS, ADJOINING PROPERTIES AND PUBLIC
RIGHTS-OF-WAY.
APPS
EBC1501.5 FIRE SAFETY DURING CONSTRUCTION.
FIRE SAFETY DURING CONSTRUCTION SHALL COMPLY WITH THE
APPLICABLE REQUIREMENTS OF THE BUILDING CODE OF NEW YORK STATE
AND THE APPLICABLE PROVISIONS OF CHAPTER 33 OF THE FIRE CODE OF
NEW YORK STATE.
MECHANICAL GENERAL NOTES:
1. ALL MATERIALS AND EQUIPMENT SUPPLIED SHALL BE INSTALLED
AS PER MANUFACTURERS SPECIFICATIONS AND AS PER LOCAL
CODES AND REQUIREMENTS.
2. FINAL LOCATION OF EQUIPMENT SHALL BE VERIFIED BY
CONTRACTOR AND SUBCONTRACTORS.
3. ALL DUCT WORK IN SPACE SHALL BE SEALED WITH APPROVED
TAPES OR SEALANTS. SUPPLY DUCTS SHALL BE INSULATED TO
R-8. ALL OTHER DUCTS TO BE INSULATED TO R-6. DUCT
TIGHTNESS SHALL BE VERIFIED BY A DUCT PRESSURIZATION TEST.
4. HVAC CONTRACTOR TO VERIFY NEW FURNITURE LOCATIONS WITH
OWNER.
5. ALL BATHROOMS SHALL BE PROVIDED WITH 3 SQUARE FEET OF
GLAZED AREA, HALF OF WHICH MUST BE OPENABLE UNLESS
ARTIFICIAL LIGHT AND INTERMITTENT MECHANICAL VENTILATION
(50 CFM) TO OUTSIDE OR 20 CFM OF CONTINUOUS VENTILATION IS
PROVIDED.
6. THE MAXIMUM LENGTH OF A CLOTHES DRYER EXHAUST DUCT
SHALL NOT EXCEED 25 FEET FROM THE DRYER LOCATION TO THE
WALL OR ROOF TERMINATION. THE MAXIMUM LENGTH OF THE DUCT
SHALL BE REDUCED 2.5 FEET FOR EACH 45-DEGREE BEND AND 5
FEET FOR EACH 90-DEGREE BEND. THE MAXIMUM LENGTH OF THE
EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT.
7. GAS CLOTHES DRYER EXHAUSTING MORE THAN 200 CFM SHALL BE
PROVIDED WITH MAKEUP AIR. WHERE A CLOSET IS DESIGNED FOR
THE INSTALLATION OF A CLOTHES DRYER, AN OPENING HAVING AN
AREA OF NOT LESS THAN 100 SQUARE INCHES FOR MAKEUP AIR
SHALL BE PROVIDED IN THE CLOSET ENCLOSURE.
8. CLOTHES WASHER DRAIN MUST BE 2 INCH DIAMETER AND
CONNECT TO A 3 INCH DIAMETER DRAIN MINIMUM.
9. APPLIANCE ACCESS -APPLIANCE SHALL BE ACCESSIBLE FOR
INSPECTION. SERVICE, REPAIR AND REPLACEMENT WITHOUT
REMOVING PERMANENT CONSTRUCTION. THIRTY INCHES OF
WORKING SPACE SHALL BE PROVIDED IN FRONT OF THE CONTROL
SIDE TO SERVICE AN APPLIANCE. APPLIANCE HAVING AN IGNITION
SOURCE SHALL BE ELEVATED SUCH THAT THE SOURCE OF
IGNITION IS NOT LESS THAN 18" ABOVE THE FLOOR IN GARAGES.
ELECTRICAL GENERAL NOTES:
1. ALL ELECTRICAL WORK IS TO COMPLY TO THE NATIONAL
ELECTRICAL CODE.
2. ALL RECESS LIGHTS INSTALLED IN A THERMAL BARRIER SHALL BE
RATED FOR INSULATED CEILINGS (IC) AND BE OF THE AIR TIGHT
TYPE WITH SEALING GASKET.
3. INSTALL 110V HARD-WIRED INTERCONNECTED SMOKE DETECTORS
THRU-OUT THE RESIDENCE PER CODE.
4. ELECTRICAL SERVICE SHALL CONTAIN AN EXTERIOR DISCONNECT
WHERE THE INTERIOR SERVICE ENTRANCE CONDUCTORS EXCEED
6 FT IN LENGTH.
5. SEE EQUIPMENT AND DEVICE MOUNTING HEIGHT DIAGRAM TO
REFERENCE DEVICE MOUNTING HEIGHTS, TYPICAL UNLESS
OTHERWISE NOTED.
6. WHERE EXISTING OR SPECIAL CONDITIONS PREVENT THE
INSTALLATION OF DEVICES AT APPROPRIATE HEIGHTS, THE
CONTRACTOR SHALL VERIFY HEIGHTS WITH THE OWNER ON SITE.
7. PROVIDE CONTINUOUS BLOCKING CONCEALED WITHIN PARTITION
AND WALL CONSTRUCTION AS REQUIRED TO PROPERLY SECURE
AND ANCHOR ANY AND ALL WALL MOUNTED EQUIPMENT,
FURNISHINGS, DEVICES, ETC.
8. WHERE SWITCHES, RECEPTACLES, THERMOSTATS, ETC. ARE
INDICATED ON WALLS IN PROXIMITY TO ONE ANOTHER, ALIGN
VERTICALLY UNLESS NOTED OTHERWISE.
9. WHERE SWITCHES, RECEPTACLES, THERMOSTATS, ETC. ARE
LOCATED ADJACENT TO DOOR FRAMES, LOCATE THE NEAR FACE
OF THE DEVICE BOX 6" FROM FINISH CASING OF DOOR FRAME,
UNLESS OTHERWISE NOTED.
10. WHERE RECEPTACLES ARE SHOWN ADJACENT TO ROOM
CORNERS, LOCATE HORIZONTALLY 2'-0" FROM CORNER TO CENTER
OF DEVICE BOX.
11. WHERE RECEPTACLES ARE SHOWN NEAR WALL CENTER, CENTER
ON WALL.
12. COORDINATE LOCATIONS OF OUTLETS, FIXTURES, SWITCHES,
SMOKE DETECTORS, CARBON MONOXIDE DETECTORS, AND ALL
OTHER DEVICES WITH OWNER PRIOR TO INSTALLATION.
13. PROVIDE SMOKE DETECTORS:
A. AT EACH SLEEPING ROOM.
B. OUTSIDE EACH SEPARATE SLEEPING AREA.
C. ON EACH ADDITIONAL STORY OF THE DWELLING INCLUDING
BASEMENT
14. R303.7 PROVIDE STAIRWAY ILLUMINATION WHERE ELECTRICAL
POWER IS PRESENT:
A. EACH INTERIOR STAIRWAY MUST BE PROVIDED WITH A MEANS
OF ILLUMINATION CAPABLE OF PROVIDING AT LEAST 1 FOOT-
CANDLE OF ILLUMINATION AT EACH LANDING OR AT AN
INTERMEDIATE POINT BETWEEN THE LANDINGS.
B. EXTERIOR STAIRWAYS MUST BE EQUIPPED WITH ARTIFICIAL
ILLUMINATION AT THE TOP LANDING.
C. EXTERIOR STAIRWAYS ACCESSING BASEMENTS SHALL BE
EQUIPPED WITH ARTIFICIAL ILLUMINATION AT THE BASE
LANDING.
UTILITY GENERAL NOTES:
1. THE CONTRACTOR SHALL TAKE CARE TO NOT DAMAGE EXISTING
UTILITIES. ANY DAMAGED UTILITIES SHALL BE REPAIRED
IMMEDIATELY BY THE CONTRACTOR AT THE CONTRACTOR'S
EXPENSE.
2. THE CONTRACTOR SHALL MAINTAIN FLOWS FOR ALL EXISTING
UTILITIES.
3. ALL UTILITY LOCATIONS, EXISTING SEWERS, WATER, TELEPHONE,
GAS ETC. MUST BE LOCATED PRIOR TO ANY CONSTRUCTION.
ELEVATIONS MUST BE VERIFIED PRIOR TO CONSTRUCTION.
REMOVAL & DEMOLITION GENERAL NOTES:
1. PRIOR TO COMMENCING WORK THE CONTRACTOR SHALL VERIFY
AND STAKE THE LOCATIONS OF ALL UNDERGROUND UTILITIES. IT
IS THE RESPONSIBILITY OF THE CONTRACTOR TO UTILIZE A
LOCATING SERVICE TO VERIFY UNDERGROUND UTILITY
LOCATIONS.
2. CONTRACTOR SHALL VERIFY THE FOLLOWING: FIELD
MEASUREMENTS, FIELD CONSTRUCTION CRITERIA, CATALOGUE
NUMBERS, AND SIMILAR DATA.
3. CONTRACTOR SHALL OBTAIN AND COMPLY WITH ALL NECESSARY
APPROVALS, PERMITS, INSPECTIONS AND CERTIFICATIONS PRIOR
TO AND DURING THE COURSE OF CONSTRUCTION.
4. CONTRACTOR IS RESPONSIBLE TO REPAIR OR REPLACE ALL ITEMS
DAMAGED OUTSIDE OF CONSTRUCTION LIMITS, OR ANY ITEMS
DISTURBED ON THE SITE WHICH ARE NOT PART OF THE IDENTIFIED
WORK OF THIS CONTRACT.
5. CONTRACTOR SHALL PROVIDE PROPER SIGNS, BARRICADES,
FENCES, TO PROTECT THE WORK, PROPERTY, EQUIPMENT AND
PERSONS FROM DAMAGE DURING ALL PHASES OF CONSTRUCTION.
6. DO NOT DRIVE VEHICLES, STORE EQUIPMENT, SPILL LIQUIDS OR
STORE CHEMICALS ON THE SITE. CONTRACTOR IS RESPONSIBLE
FOR DAMAGE OUTSIDE THE CONSTRUCTION LIMIT LINE AND WITHIN
PROTECTION AREAS.
7. CONTRACTOR SHALL STRIP, STORE, AND REUSE ALL TOPSOIL
FROM AREAS TO BE PAVED OR RE-GRADED. PROVIDE SEDIMENT
CONTROL FENCE AROUND BASE OF TOPSOIL STOCKPILE.
8. IN AREAS WHERE PLANT MATERIAL IS PROPOSED ON AREAS OF
EXISTING PAVEMENT, EXCAVATE EXISTING SOIL TO A DEPTH OF 30"
AND REPLACE WITH APPROVED TOPSOIL, COORDINATE WITH
PLANTING PLAN.
9. ALL EXISTING MATERIAL TO BE SALVAGED SHALL BE VERIFIED BY
THE OWNER'S REPRESENTATIVE AND REMOVED AND STORED BY
CONTRACTOR IN A LOCATION COORDINATED WITH OWNER.
CONTRACTOR SHALL COMPENSATE OWNER FOR ANY DAMAGE TO
SALVAGED MATERIALS THAT OCCURS DURING REMOVAL, STORAGE
OR REINSTALLATION.
10. ALL EXISTING UTILITIES TO REMAIN, UNLESS OTHERWISE NOTED.
11. WHEN PRACTICAL ALL SAW-CUTS INTO EXISTING CONCRETE
SHALL OCCUR AT EXISTING CONSTRUCTION OR EXPANSION
JOINTS.
12. REMOVE CONSTRUCTION AS REQUIRED FOR PROPER
INSTALLATION OF NEW OPENING AND TO PROPERLY RECEIVE NEW
CONSTRUCTION.
13. REMOVE WALL MOUNTED ELECTRICAL RACEWAY, DEVICES,
CABLING AND MOUNTING AND ANCHORAGES COMPLETE. CLEAN,
PATCH AND REPAIR REMAINING WALL SURFACES AS REQUIRED TO
PROVIDE A SMOOTH SURFACE READY TO RECEIVE PAINT.
14. COORDINATE EXACT EXTENT OF ALL REMOVALS AND
MODIFICATIONS WITH REQUIREMENTS OF NEW CONSTRUCTION.
DIMENSIONED REMOVALS ARE FOR GENERAL INFORMATION
PURPOSES ONLY. REFER TO PLANS AND DETAILS FOR ADDITIONAL
INFORMATION AND REQUIREMENTS.
15. ALL REMAINING WALL, FLOOR, CEILING AND ANY AND ALL OTHER
EXISTING CONSTRUCTION DAMAGED DURING REMOVALS ARE TO
BE REPAIRED SUCH THAT REMAINING SURFACES ARE SMOOTH AND
FLUSH WITH SURROUNDING MATERIALS AND READY FOR
APPLICATION OF REQUIRED FINISHES. PROVIDE NEW MATERIALS
TO MATCH EXISTING ADJACENT MATERIALS AND FINISHES AS
REQUIRED TO MATCH EXISTING CONSTRUCTION.
16. REMOVE ALL DISCONTINUED OR NON-FUNCTIONING WIRE,
TELEPHONE AND DATA COMMUNICATIONS CABLING COMPLETE.
17. CONTRACTOR IS RESPONSIBLE TO MEET ALL OSHA REGULATIONS
AND BUILDING CODE REQUIREMENTS FOR THE REMOVAL OF
EXISTING BUILDINGS AND SELECTIVE DEMOLITION OF BUILDING
COMPONENTS.
CODE NOTES GENERAL NOTES
GROSS BUILDING AREACODE CLASSIFICATIONS
Scale
Project number
Date
devon telberg, aia
665 Saratoga Rd
Wilton, NY 12831
t (518) 212-7778
e devon@telbergstudio.com PROGRESS -NOT FOR CONSTRUCTI ON 8/12/2024 1:57:09 AMAs indicated
A010
Site Plan & Code Schedule
2404
The Bergman Residence 8/11/24
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation No. Description Date
1/8" = 1'-0"1 Site Plan
Garage Doors No less than 0.40 ECCNYS Table R402.5.2
Swinging Doors No less than 0.20 ECCNYS Table R402.5.2
Sliding Doors No less than 0.20 ECCNYS Table R402.5.2
Windows No less than 0.20 ECCNYS Table R402.5.2
Air Barrier No less than 0.004 ECCNYS R402.5.1.2.1
Air Leakage - Thermal Envelope Air Permeability - cfm/ft2
PF > or equal 0.5 0.61 ECCNYS Table R402.1.4
0.2 < or equal PF < 0.5 0.46 ECCNYS Table R402.1.4
SHGC - PF < 0.2 0.38 0.35 ECCNYS Table R402.1.4
Glazed Fenestration SHGC ECCNYS Table R402.1.4
Fenestration U-Factor
Fixed
Operable
Entrance Doors
U-0.38
U-0.45
U-0.77
U-0.55 ECCNYS Table R402.1.4
Fenestration Requirements
Crawl Space Wall R-Value R-15/19 R-15 ECCNYS Table R402.1.2
Slab R-Value & Depth R-10 & 2 ft R-15 & 2 FT ECCNYS Table R402.1.2
Basement Wall R-Value R-15/19 R15 ECCNYS Table R402.1.2
Floor R-Value R-30 N/A ECCNYS Table R402.1.2
Mass Wall R-Value R-15/17 R-15
Wood Frame Wall R-Value R-20 or 13+5 R-21 ECCNYS Table R402.1.2
Ceiling R-Value (Without Attics) R-38 R-38 ECCNYS Table R402.2.2
Opaque Thermal Envelope Requirements
C4 Commercial Energy Efficiency Required Provided Reference
Degree Days 7244 Zone 14A
Climate Zone Saratoga County 5A ECCNYS Table R301.1
C3 General Requirements Reference
2020 Energy Conservation Code of New York State ECCNYS
2020 Existing Building Code of New York State EBCNYS
2020 Building Code of New York State BCNYS
Applicable Codes
Energy Code Information Reference
1/8" = 1'-0"2 Basement Life Safety Plan
1/8" = 1'-0"3 First Floor Life Safety Plan
1/8" = 1'-0"4 Second Floor Life Safety Plan
1/8" = 1'-0"5 Attic Life Safety Plan
UP
DN
UP
11' - 10"REMOVE MECHANICAL
SYSTEMS COMPLETE,
REPAIR SUBSTRATE TO
RECEIVE NEW SYSTEMS
REMOVE EXISTING
STAIR COMPLETE
REMOVE EXISTING ADDITION
COMPLETE: FLOOR, WALLS,
COLUMNS, STAIR, DOORS.
REMOVE EXISTING EXTERIOR
BRICK WALL AND PROVIDE
TEMPORARY SHORING AND
SUPPORT FOR FLOOR ABOVE.
REMOVE EXISTING CABINETRY
COMPLETE, PATCH AND REPAIR
SUBSTRATE TO RECEIVE NEW
FINISHES
EXISTING WINDOWS TO REMAIN.
REMOVE TRIMWORK AT WINDOWS
AND FINISHES COMPLETE. PATCH
AND REPAIR SUBSTRATE TO
RECEIVE NEW WALL AT INTERIOR
SIDE, TYP.
2
A300
REMOVE HEATING UNIT COMPLETE
7
A301
DEMOLITION NOTES
1. REMOVE DOOR AND FRAME SYSTEM COMPLETELY, REPAIR
ROUGH OPENING TO RECIEVE NEW DOOR OPENING
TRIMWORK
2. EXISTING MILLWORK AND APPLIANCES TO BE REMOVED
COMPLETE.
3. REMOVE EXISTING HEATING SYSTEMS COMPLETE.
4. ELEMENTS TO REMAIN IN PLACE SHALL BE PROTECTED
FROM DAMAGE, DUST AND DEBRIS.
5. CONTRACTOR TO MAINTAIN WATER TIGHT INTEGRITY OF
BUILDING AT ALL TIMES.
6. ALL FLOOR AND WALL CONDITIONS WHICH ARE TO RECEIVE
NEW CONSTRUCTION ARE TO BE DEMOLISHED AS INDICATED
AND PROPERLY PREPPED TO RECEIVE NEW FINISHES, U.O.N.
7. ALL FLOOR, WALL, AND CEILING CONDITIONS THAT ARE
DISTURBED BY DEMOLITION ARE TO BE PATCHED, REPAIRED
AND/OR PAINTED WITH SIMILAR MATERIALS. REFER TO
PROPOSED PLANS FOR LOCATIONS.
8. ALL ELECTRICAL REMOVALS TO BE PERFORMED BY A
LICENSED ELECTRICIAN.RELABEL PANELS. FOLLOW N.E.C.
(NFPA 70). PROVIDE THIRD-PARTY INSPECTION.
9. PRIOR TO COMMENCING REMOVALS WORK, AND UNTIL SUCH
TIME THAT FINAL WORK IS IN PLACE, CONTRACTOR SHALL
ASCERTAIN REQUIREMENTS FOR, AND PROVIDE, BRACING,
SHORING AND OTHER TEMPORARY SYSTEMS OF SUPPORT
NEEDED TO PREVENT DAMAGE TO EXISTING CONSTRUCTION
WHICH IS SCHEDULED TO REMAIN.
10. SHUT OFF, CAP AND OTHERWISE PROTECT EXISTING
UTILITIES IN STRICT ACCORDANCE WITH THE REQUIREMENTS
OF THE PUBLIC AGENCIES OR UTILITIES HAVING
JURISDICTION AND AS DIRECTED ON THE MECHANICAL AND
ELECTRICAL DRAWINGS.
11. COMPLETELY REMOVE ITEMS SCHEDULED TO BE
DEMOLISHED AND REMOVED, LEAVING SURFACES CLEAN,
SOLID AND READY TO RECEIVE NEW MATERIALS SPECIFIED
ELSEWHERE.
12. DEMOLISHED MATERIALS SHALL BE COMPLETELY REMOVED
FROM THE JOB SITE AND DISPOSED OF PROPERLY UNLESS
OTHERWISE DIRECTED BY OWNER.
13. ALL EXISTING ITEMS SCHEDULED TO REMAIN SHALL BE
FULLY PROTECTED FROM ANY DELETERIOUS EFFECT
DURING ALL PHASES OF THE PROJECT. ANY DAMAGE TO
EXISTING ITEMS (WHETHER THEY ARE SHOWN ON THE
DRAWINGS OR NOT) SHALL BE CORRECTED TO THE
SATISFACTION OF THE OWNER AT THE EXPENSE OF THE
CONTRACTOR.
DEMOLITION LEGEND
EXISTING WALL TO BE REMOVED
EXISTING DOOR AND FRAME TO BE REMOVED
EXISTING WALL TO REMAIN
EXISTING DOOR TO REMAIN
14. ALL REMOVALS INDICATED MAY REQUIRE THE
COORDINATED REMOVAL OF EXISTING MECHANICAL,
ELECTRICAL, SECURITY SYSTEM, FIRE ALARM SYSTEM,
DATA AND TELEPHONE SYSTEM AND PLUMBING
EQUIPMENT AND LINES -REFER TO MECHANICAL AND
ELECTRICAL CONTRACTORS FOR INFORMATION
REGARDING EXISTING AND NEW H.V.A.C., PLUMBING,
ELECTRICAL ETC., RELATED WORK PRIOR TO
COMMENCING DEMOLITION.
15. COORDINATE ALL PARTIAL PARTITION REMOVAL
DIMENSIONS WITH FLOOR PLAN PRIOR TO DEMOLITION
TAKING PLACE.
16. REMOVE ALL ABANDONED PIPING, WIRING, EQUIPMENT,
LIGHTING, DUCTWORK, TUBING, SUPPORTS, FIXTURES,
ETC., BACK TO ITS ORIGINATION POINT, IN ITS ENTIRETY.
VISIT EACH ROOM, CRAWL SPACE, ROOF, AND BUILDING
EXTERIOR TO DETERMINE TOTAL SCOPE OF WORK.
17. DISCONNECT, REMOVE, RELOCATE AND PERMANENTLY
RECONNECT ANY AND ALL EXISTING MECHANICAL AND
ELECTRICAL WORK THAT IS REQUIRED TO REMAIN, BUT
INTERFERING WITH NEW CONSTRUCTION.
18. THE CONTRACTOR SHALL NOT LEAVE, ABANDONED,
PIPING, DUCTWORK, CONDUIT OR OUTLET BOXES IN
PLACE, EXCEPT THOSE ABANDONED ITEMS
PERMANENTLY BURIED AND CONCEALED IN EXISTING
WALLS AND FLOORS. THE CONTRACTOR SHALL REMOVE
ALL EXISTING EXPOSED AND ABANDONED PIPING,
DUCTWORK, OUTLET BOXES, CONDUITS, ETC., EVEN
THOSE ABANDONED ABOVE EXISTING CEILINGS, IN
EITHER RENOVATED AREAS, OR IN AREAS NOT BEING
RENOVATED. THOSE LEFT ABANDONED WITHIN EITHER
EXISTING WALLS OR FLOORS, SHALL BE CUT OFF AT THE
POINT WHERE THEY EXIT WALL OR FLOOR, CAPPED AND
COVERED FLUSH.
19. EXISTING EQUIPMENT CONNECTIONS AND WIRING
DEVICES, SCHEDULED FOR RELOCATION, SHALL BE
EXTENDED TO NEW LOCATION UTILIZING THE SAME
MATERIALS AND METHODS PREVIOUSLY USED.
(EXAMPLE: IF EXISTING WIRING DEVICE OUTLET WAS
PREVIOUSLY INSTALLED WITH GALVANIZED RIGID STEEL
CONDUIT, NEW RELOCATED OUTLET SHALL BE EXTENDED
WITH NEW GALVANIZED RIGID STEEL CONDUIT.)
TOP OF SLAB AT -5" BELOW EXISTING
BASEMENT FLOOR ELEVATION
PROVIDE CONTINUOUS TOP & BTM RUBBER
WATER STOP. CONNECT NEW CONC. WALL TO
EXTG, PRE-DRILL 4" DEEP HOLES INTO EXTG WALL
12" OC. ENTIRE HEIGHT OF WALL, SET 8" LONG #4
REBAR INTO THE PRE-DRILLED HOLE WITH
EPOXY. POUR NEW WALL OVER EXPOSED 4" OF
REBAR (TYP.)
8" CONC. FOUNDATION WALLS, #4
VERTICAL REBAR AT 4'-0" OC., 6"
INTO FOOTING UP TO FIRST FLOOR
LEVEL
FOOTING
1' - 4"
WALL
8".
T/O CURB
TOP OF RETAINING
WALL AT GRADE
DEPRESSION FOR 6" X 6" TRENCH DRAIN10' - 10"10' - 1"12' - 4 1/2"23' - 4 1/4"
11' - 10"
+ 4' - 6 1/2"
T/O WALL ABV BASEMENT LEVEL, TYP.1' - 0"SAW CUT NEW OPENING IN
EXIST. FDN WALL 7'-0" HIGH
EXTG F.J. TO REMAIN
TYPICAL AT TOP OF FOUNDATION WALL:
TREATED 2X12 LEDGER
STAGGER BOLTED HI-LOW
W/1/2"Ø GALVANIZED EXPANSION
BOLTS & WASHERS AT 12" O.C. &
MAX OF 2" FOR EA. END OF
LEDGER FOR NEW JOIST
HANGERS WRAPPED W/Z-FLASHING
EXTG F.J. TO REMAIN
EXISTING WINDOW
OPENINGS TO REMAIN
TOP OF EXTG SLAB AT 0" -0"TOP OF EXTG SLAB AT -0" -4"
TOP OF NEW SLAB
AT -0' - 6 1/2" BELOW
EXTG BASEMENT LEVEL6"1' - 7 1/4"1' - 0"1' - 0"SLOPE-1' - 6 1/2"
T/O FOOTING
CONCRETE IN PLACE WITH 20" X
12" 3 #4 REBAR
FOUNDATION FLOOR TYPE 1
4" CONC. WITH W.W.F. ON
POLYEHTYLENE VAPOR BARRIER ON
R-10 POLYISOCYANURATE RIGID
INSULATION ON 4" STONE ON
COMPACTED FILL
PATIO AT GRADE
STONE SET IN 4" CONC. SLAB ON 4"
GRAVEL. TOP OF NEW SLAB AT -0 -7" EL.
BELOW T.O.S. ADDITION LEVEL 1
A300
1
A301
1
A3022
1
A3022
2
A300
W6
W6
W4T
4' - 0 1/2"2' - 1 1/2"
5' - 8 1/4"8' - 8"6' - 2"36S60
32
36D164
INFILL WALLS TO ALIGN
WITH EXISTING ADJACENT
WALLS
199 SF
MECHANICAL ROOM
20
207 SF
PASSAGE
21
194 SF
GYM
22
202 SF
THEATER
23
421 SF
GAME ROOM
24
49 SF
POWDER RM
25
ALIGN WALLS BELOW WITH
FACE OF STAIR CARRIAGE
LANDING ABOVE
W4T
UNOCCUPIED
SPACE
ALIGN
-0' - 6 1/2" T/O CONC. SLAB
-0' - 6 1/2" T/O FF
EQ EQ
FACE OF FOUNDATION WALL
CONC. RETAINING WALL
BLUESTONE PATIO STONE FLOOR
6X6 TRENCH DRAIN
7
A301
NOTE:
1. EXPOSED BRICK WALL AT EXISTING
LOCATIONS. PATCH AND REPAIR GROUT IN
EXPOSED LOCATIONS. APPLY CLEAR
SEALER TO PROTECT SURFACES.
2. FOR INTERIOR FINISHES, CABINETRY,
FIXTURE SELECTIONS AND TRIMWORK,
REFER TO INTERIOR DWGS.
FRAMING PLAN NOTES FRAMING PLAN LEGEND
1. ALL DIMENSIONS ARE FROM FACE OF FRAMING U.O.N.
2. CONC. CONTRACTOR TO BE RESPONSIBLE FOR ALL CONC. CUTTING & REMOVAL.
3. THE CONTRACTOR SHALL VERIFY EXISTING AND FIELD CONDITIONS. THE CONTRACTOR SHALL
NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR REQUIRED MODIFICATIONS PRIOR TO
COMMENCING INSTALLATION OF EQUIPMENT AND ASSOCIATED WORK.
4. PROVIDE DOUBLE STUDS AT JAMBS OF ALL DOORS, WINDOWS AND SIMILAR OPENINGS.
5. ALL CONNECTORS USED IN PRESSURE-TREATED WOOD FRAMING SHALL BE STAINLESS OR
GALVANIZED STEEL.
6. ALL HEADERS, FLOOR JOISTS & RAFTERS ARE TO BE SPRUCE-PINE-FIR #2 OR BETTER, STUDS -
STUD GRADE
7. ALL HEADERS ARE TO BE 3-2X10'S UNLESS OTHERWISE SPECIFIED.
8. JOISTS:
A. SHALL BE SUPPORTED LATERALLY (TO PREVENT ROTATION) AT THE ENDS BY FULL DEPTH SOLID
BLOCKING NOT LESS THAN 2" NOMINAL THICKNESS OR BY ATTACHMENT TO HEADER, BAND, RIM
JOIST, OR TO AN ADJOINING STUD.
B. IN SEISMIC DESIGN CATEGORIES D1 AND D2, LATERAL RESTRAINT MUST BE PROVIDED AT EACH
INTERMEDIATE SUPPORT R502.7.
9. NOTCHING REQUIREMENTS FOR EXTERIOR LOAD BEARING WALLS:
A. LOAD BEARING WALLS CUT MORE THAN 50% MUST BE SECURED BY A METAL TIE .054 THICK BY 1
1/2 INCHES WIDE WITH 8-16D NAILS ON EACH SIDE EXCEPT WHERE EXTERIOR WALLS ARE
COVERED BY SHEATHING.
B. HOLES BETWEEN 40% AND 60% OF STUD DEPTH REQUIRE DOUBLE STUDS.
C. NO HOLES ARE PERMITTED WITHIN 5/8 INCH OF THE EDGE OF ANY STUD.
D. NO HOLES ARE PERMITTED WITHIN ON THE SAME CROSS SECTION AS A NOTCH ON ANY STUD.
E. NO NOTCHES ARE PERMITTED TO BE MORE THAN 25% OF THE STUD DEPTH . R502.8., 602.6(1).(2)
R602.6.1
10. ALL HEADERS, GIRDERS SUPPORTING BEAMS AND OTHER STRUCTURAL COMPONENTS ARE
COVERED UNDER R301.1.3 ENGINEERED DESIGN. THESE DRAWINGS HAVE BEEN PREPARED UNDER
THE DIRECT SUPERVISION AND SEALED BY A NEW YORK STATE CERTIFIED PROFESSIONAL
STRUCTURAL ENGINEER IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE (ASCE-7)
11. ALL TOP PLATES AND SILL PLATES SHALL BE #3 SYP OR DFL (19% MC) OR BETTER.
12. HEADERS, FLUSH BEAMS, AND DROP BEAMS SHALL BE #2 DFL OR SYP (19%MC) OR BETTER, U.O.N.
13. ALL HEADERS AND BEAMS SHALL HAVE DOUBLE STUD PACK UNDER EACH END, U.O.N.
14. SIMPSON CS20 X 48" LONG STRAPS SPACED AT 48" O.C. SHALL BE USED ALONG THE EXTERIOR OF
THE BUILDING CENTERED ACROSS THE FLOOR CAVITY.
15. THE STABILITY OF THE FLOOR IS NOT ACHEIVED UNTIL THE DECKING HAS BEEN PROPERLY
INSTALLED AND FASTENED.
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME TO REMAIN
NEW WALL
NEW DOOR
TYPE ID
W4
W4T
W6
PARTITION ASSEMBLY
1/2" GYP BD ON 2X4 WD FRAMING ON 1/2"
GYP BD, TYPICAL U.O.N.
1/2" GYP BD ON TURNED 2X4 WD FURRING
1/2" GYP BD ON 2X6 WD FRAMING ON 1/2"
GYP BD
WALLS WITH THIS SYMBOL INDICATE 3"
SOUND-ABSORBING INSULATION IS ADDED
FOR ACOUSTICAL INSULATION
DESIGN LOADS:
FIRST FLOOR
SECOND & ATTIC FLOOR
ROOF
LOADS:
40 PSF LIVE / 10 PSF DEAD
40 PSF LIVE / 10 PSF DEAD
50 PSF GROUND SNOW
47 PSF FLAT ROOF SNOW
20 PSF DEAD
115 MPH WIND
EXPOSURE: B
1. ALL CONC. TO BE MIN. 3000 PSI AT 28 DAY COMPRESSIVE STRENGTH.
2. ALL CONC. TO REST ON UNDISTURBED SOIL OF 2000 PSF BEARING
CAPACITY MINIMUM, OR COMPACTED STRUCTURAL FILL OR
BEDROCK.
3. CONC. FOOTINGS TO BE LOCATED MIN. -4'-0" FROM GRADE TO TOP
OF FOOTING U.O.N. FOOTINGS MAY BE STEPPED DOWN OR
LOWERED TO REACH AN ACCEPTABLE BEARING STRATUM AS
DETERMINED BY GEOTECHNICAL ENGINEER.
4. DO NOT PLACE FOOTINGS IN WATER OR IN FROZEN GROUND.
5. DO NOT ALLOW GROUND BENEATH FOOTINGS OR SLABS TO FREEZE.
6. CENTER FOOTINGS UNDER WALLS OR GRADE BEAMS U.O.N.
7. WHERE CONTROL JOINTS ARE NOT INDICATED ON PLAN, PROVIDE
CONTROL JOINTS SPACED AT 35 FEET, MAXIMUM.
8. CONCRETE WALLS SHALL ATTAIN A MAXIMUM STRENGTH OF 70% F'C
BEFORE PLACING BACKFILL AGAINST THEM.
9. EXTEND WALL FOOTING REINFORCEMENT INTO COLUMN FOOTINGS
WITH A MINIMUM EMBEDMENT EQUAL TO THE MINIMUM BAR
DEVELOPMENT LENGTH.
10. CAST STEPPED FOOTINGS MONOLITHICALLY.
11. DO NOT LOCATE PENETRATIONS THROUGH FOOTINGS. STEP
FOOTINGS DOWN AS REQUIRED TO LOCATE PENETRATION IN WALL.
12. CHAMFER EXPOSED CONCRETE CORNERS AND EDGES 3/4 INCH
U.O.N.
13. CONCRETE COVER FOR REINFORCEMENT SHALL BE 1 1/2" MIN.
FOUNDATION PLAN NOTES
Scale
Project number
Date
devon telberg, aia
665 Saratoga Rd
Wilton, NY 12831
t (518) 212-7778
e devon@telbergstudio.com PROGRESS -NOT FOR CONSTRUCTI ON 8/12/2024 1:57:10 AMAs indicated
A100
Basement Removals & Proposed Plan
2404
The Bergman Residence 8/11/24
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
1/4" = 1'-0"1 Basement Demolition Plan
1/4" = 1'-0"2 Basement Foundation Plan
1/4" = 1'-0"3 Basement Framing Plan
No. Description Date
Door & Window Schedule
Type Mark Quantity Width Height Type Comments Manufacturer Model Glass Type
Daylight
Area
Heat Transfer
Coefficient (U)
Thermal Resistance
(R)Comments
D62 1 6' - 0 5/8" 6' - 10" Exterior 2DR Marvin UOFD2.25G2 6068 IG Low E II with Argon 24 SF
D164 1 13' - 11" 6' - 10" Exterior 2DR 2WN Marvin UOFDG2 14068 IG Low E II with Argon 58 SF
B60 1 5' - 0" 6' - 8" Interior BiFold 0 SF
D60 1 5' - 0" 6' - 8" Interior Double Panel 0 SF
P32 2 2' - 8" 6' - 8" Interior Pocket Panel 0 SF
30 6 2' - 6" 6' - 8" Interior Single Panel 0 SF 0.3865 BTU/(h·ft²·°F) 2.5873 (h·ft²·°F)/BTU
32 7 2' - 8" 6' - 8" Interior Single Panel 0 SF 0.3865 BTU/(h·ft²·°F) 2.5873 (h·ft²·°F)/BTU
36 2 3' - 0" 6' - 8" Interior Single Panel 0 SF 0.3865 BTU/(h·ft²·°F) 2.5873 (h·ft²·°F)/BTU
S60 3 5' - 0" 6' - 8" Interior Sliding 2-Panel 0 SF
82 SF
Window # Count Width Height Head Height Manufacturer Model
Visual Light
Transmittance
Daylight
Area
Vent
Area
Heat Transfer
Coefficient (U)
Thermal Resistance
(R)Comments
26 1 2' - 7" 5' - 10" 8' - 10" 0.81 0 SF 0 SF 0.5511
BTU/(h·ft²·°F)
1.8146 (h·ft²·°F)/BTU
33 1 3' - 0" 3' - 0" 6' - 6" 0 SF 0 SF
35 12 2' - 11 1/4" 4' - 11 1/2" 7' - 6" Marvin UDHG2 3042 119 SF 0 SF
36 3 2' - 11 1/4" 5' - 11 1/2" 9' - 0" Marvin UDHG2 3036 37 SF 0 SF
39 4 3' - 0" 8' - 9 1/8" 9' - 0" Marvin UCA3684 83 SF 80 SF
42 1 4' - 0" 2' - 6" 5' - 0" 0 SF 0 SF
43 2 4' - 0" 2' - 7 1/8" <varies> Marvin UFCA4832 13 SF 0 SF
Total: 252 SF 80 SF
UP
DN
DN
DN
DN
DN
11 10 9 8 7 6 5 4 3 2 1
141312
DN
3
A300
1' - 4 1/2"15' - 11"3' - 9"
5' - 2"3' - 4 1/2"
PATCH AND REPAIR
OPENING FOR INFILL
REMOVE BRICK CHIMNEY
COMPLETE, FROM
BASEMENT TO ROOF TOP
REMOVE STAIR TO
BASEMENT COMPLETE,
PATCH AND REPAIR
OPENING TO RECEIVE
NEW FLOOR INFILL
CUT AND REMOVE FLOOR
CONSTRUCTION FOR NEW
MECH SHAFT OPENING,
COORDINATE WITH MECH
CONTRACTOR FOR
OPENING SIZE & LOCATION
FOUNDATION, COLUMNS, WALLS, DOORS, STAIRS, ROOFS
REMOVE EXTG ADDITION CONSTRUCTION ENTIRELY:
EXISTING LOAD-
BEARING WALL TO
REMAIN
TEMPORARILY SHORE &
SUPPORT EXISTING LOAD-
BEARING WALL TO BE
REMOVED
PATCH AND REPAIR EXISTING BRICK
AT STRUC. CONNECTIONS, TYP.
REMOVE EXISTING HANDRAIL,
BALUSTERS AND POSTS.
PROVIDE TEMP PROTECTION
DURING CONSTRUCTION
EXTG BDRM
EXTG BDRM
EXTG KITCHEN
EXTG BDRM
EXTG LVG RM
EXTG DNG RM
EXTG BATHRM
DEMOLITION NOTES
1. REMOVE DOOR AND FRAME SYSTEM COMPLETELY, REPAIR
ROUGH OPENING TO RECIEVE NEW DOOR OPENING
TRIMWORK
2. EXISTING MILLWORK AND APPLIANCES TO BE REMOVED
COMPLETE.
3. REMOVE EXISTING HEATING SYSTEMS COMPLETE.
4. ELEMENTS TO REMAIN IN PLACE SHALL BE PROTECTED
FROM DAMAGE, DUST AND DEBRIS.
5. CONTRACTOR TO MAINTAIN WATER TIGHT INTEGRITY OF
BUILDING AT ALL TIMES.
6. ALL FLOOR AND WALL CONDITIONS WHICH ARE TO RECEIVE
NEW CONSTRUCTION ARE TO BE DEMOLISHED AS INDICATED
AND PROPERLY PREPPED TO RECEIVE NEW FINISHES, U.O.N.
7. ALL FLOOR, WALL, AND CEILING CONDITIONS THAT ARE
DISTURBED BY DEMOLITION ARE TO BE PATCHED, REPAIRED
AND/OR PAINTED WITH SIMILAR MATERIALS. REFER TO
PROPOSED PLANS FOR LOCATIONS.
8. ALL ELECTRICAL REMOVALS TO BE PERFORMED BY A
LICENSED ELECTRICIAN.RELABEL PANELS. FOLLOW N.E.C.
(NFPA 70). PROVIDE THIRD-PARTY INSPECTION.
9. PRIOR TO COMMENCING REMOVALS WORK, AND UNTIL SUCH
TIME THAT FINAL WORK IS IN PLACE, CONTRACTOR SHALL
ASCERTAIN REQUIREMENTS FOR, AND PROVIDE, BRACING,
SHORING AND OTHER TEMPORARY SYSTEMS OF SUPPORT
NEEDED TO PREVENT DAMAGE TO EXISTING CONSTRUCTION
WHICH IS SCHEDULED TO REMAIN.
10. SHUT OFF, CAP AND OTHERWISE PROTECT EXISTING
UTILITIES IN STRICT ACCORDANCE WITH THE REQUIREMENTS
OF THE PUBLIC AGENCIES OR UTILITIES HAVING
JURISDICTION AND AS DIRECTED ON THE MECHANICAL AND
ELECTRICAL DRAWINGS.
11. COMPLETELY REMOVE ITEMS SCHEDULED TO BE
DEMOLISHED AND REMOVED, LEAVING SURFACES CLEAN,
SOLID AND READY TO RECEIVE NEW MATERIALS SPECIFIED
ELSEWHERE.
12. DEMOLISHED MATERIALS SHALL BE COMPLETELY REMOVED
FROM THE JOB SITE AND DISPOSED OF PROPERLY UNLESS
OTHERWISE DIRECTED BY OWNER.
13. ALL EXISTING ITEMS SCHEDULED TO REMAIN SHALL BE
FULLY PROTECTED FROM ANY DELETERIOUS EFFECT
DURING ALL PHASES OF THE PROJECT. ANY DAMAGE TO
EXISTING ITEMS (WHETHER THEY ARE SHOWN ON THE
DRAWINGS OR NOT) SHALL BE CORRECTED TO THE
SATISFACTION OF THE OWNER AT THE EXPENSE OF THE
CONTRACTOR.
DEMOLITION LEGEND
EXISTING WALL TO BE REMOVED
EXISTING DOOR AND FRAME TO BE REMOVED
EXISTING WALL TO REMAIN
EXISTING DOOR TO REMAIN
14. ALL REMOVALS INDICATED MAY REQUIRE THE
COORDINATED REMOVAL OF EXISTING MECHANICAL,
ELECTRICAL, SECURITY SYSTEM, FIRE ALARM SYSTEM,
DATA AND TELEPHONE SYSTEM AND PLUMBING
EQUIPMENT AND LINES -REFER TO MECHANICAL AND
ELECTRICAL CONTRACTORS FOR INFORMATION
REGARDING EXISTING AND NEW H.V.A.C., PLUMBING,
ELECTRICAL ETC., RELATED WORK PRIOR TO
COMMENCING DEMOLITION.
15. COORDINATE ALL PARTIAL PARTITION REMOVAL
DIMENSIONS WITH FLOOR PLAN PRIOR TO DEMOLITION
TAKING PLACE.
16. REMOVE ALL ABANDONED PIPING, WIRING, EQUIPMENT,
LIGHTING, DUCTWORK, TUBING, SUPPORTS, FIXTURES,
ETC., BACK TO ITS ORIGINATION POINT, IN ITS ENTIRETY.
VISIT EACH ROOM, CRAWL SPACE, ROOF, AND BUILDING
EXTERIOR TO DETERMINE TOTAL SCOPE OF WORK.
17. DISCONNECT, REMOVE, RELOCATE AND PERMANENTLY
RECONNECT ANY AND ALL EXISTING MECHANICAL AND
ELECTRICAL WORK THAT IS REQUIRED TO REMAIN, BUT
INTERFERING WITH NEW CONSTRUCTION.
18. THE CONTRACTOR SHALL NOT LEAVE, ABANDONED,
PIPING, DUCTWORK, CONDUIT OR OUTLET BOXES IN
PLACE, EXCEPT THOSE ABANDONED ITEMS
PERMANENTLY BURIED AND CONCEALED IN EXISTING
WALLS AND FLOORS. THE CONTRACTOR SHALL REMOVE
ALL EXISTING EXPOSED AND ABANDONED PIPING,
DUCTWORK, OUTLET BOXES, CONDUITS, ETC., EVEN
THOSE ABANDONED ABOVE EXISTING CEILINGS, IN
EITHER RENOVATED AREAS, OR IN AREAS NOT BEING
RENOVATED. THOSE LEFT ABANDONED WITHIN EITHER
EXISTING WALLS OR FLOORS, SHALL BE CUT OFF AT THE
POINT WHERE THEY EXIT WALL OR FLOOR, CAPPED AND
COVERED FLUSH.
19. EXISTING EQUIPMENT CONNECTIONS AND WIRING
DEVICES, SCHEDULED FOR RELOCATION, SHALL BE
EXTENDED TO NEW LOCATION UTILIZING THE SAME
MATERIALS AND METHODS PREVIOUSLY USED.
(EXAMPLE: IF EXISTING WIRING DEVICE OUTLET WAS
PREVIOUSLY INSTALLED WITH GALVANIZED RIGID STEEL
CONDUIT, NEW RELOCATED OUTLET SHALL BE EXTENDED
WITH NEW GALVANIZED RIGID STEEL CONDUIT.)
OPEN TO BELOW
13' - 3 1/2"2' - 3 1/2"6' - 5 1/4"2' - 9 1/2"11' - 3"6' - 3"5' - 6 1/2"OPENING
3' - 0"
2' - 4"PER FRPL MANF.FRAMED OPENING4X4 WD POST COL.NEW ADDITION9' - 8 1/4"35' - 0 3/4" NEW ADDITION
NEW ADDITION15' - 5 1/4"EXISTING TO REMAINNEW 2X10 WD FRAME
FLOOR INFILL FLUSH
WITH EXTG ADJACENT
WD FRAMING 14' - 11 3/4"6' - 5 3/4"8' - 0 3/4"20' - 8 3/4"
5' - 8 1/2"
1' - 8 1/4"OPENING3' - 3 3/4"SPF 2X10 AT 12" O.C.5' - 5 1/4"3' - 6 1/2"REMOVE ALL BRICK ABOVE TO 2ND FLR FRAMING
15' - 11"
DBL. 2X10 HEADERS AT
ALL NEW DOOR AND
WINDOW OPENINGS, TYP.
INFILL WD FRAMING AT EXTG
OPENINGS TO MATCH EXISTING
TYPE & ALIGN WITH ADJ, TYP.
EXTG 2X8
TO REMAIN EXTG 2X8 TO REMAINEXTG 2X8 TO REMAINPATCH AND REPAIR EXTG
OPENING, INFILL WD FRAMING
UP TO 3'-4" HT AFF FOR NEW
OPENING
PATCH AND REPAIR EXTG
OPENINGS
2' - 5 3/4"3' - 2"3' - 2"9' - 9 1/4"3' - 5 1/4"3' - 5 1/4"3' - 5 1/4"6' - 2 1/4"2' - 6 1/4"1' - 9 1/4"3' - 3"3' - 3"LENGTHS3 1/2 BRICKLENGTHS
5 1/2 BRICK
LENGTHS
5 1/2 BRICK
8' - 0" (EQ)8' - 0" (EQ)
P32
30
P32
36
36
36
39393939353535
35
26
30
LANDING
4' - 0"
(10) T AT 11" D EA.
9' - 2"
(3) T AT 11" D EA.
1' - 10"9' - 2" LANDING4' - 0 3/4"1' - 0 1/2"4' - 0 3/4"NEW WALL
PENETRATION FOR
NEW FIREPLACE
VENT
REPLACE WINDOW WITH
NEW AT SAME LOCATION,
PATCH AND REPAIR ROUGH
OPENING
EXISTING STAIR TREAD AND
STRINGERS TO REMAIN
NEW WD RAILING, TOP OF
HANDRAIL AT 34" HT ABOVE
TREAD, TYP.
NEW PTD. WALL UNDER STAIR
EXISTING LOAD-BEARING
WALL TO REMAIN
LOUNGE
16 OFFICE
17
POWDER RM 1
18
LIVING
11
KITCHEN
13
DINING
12
PANTRY
14
ENTRY
10
PASSAGE 1
15
CLOSET
10A
1' - 5"1' - 5"ALIGNEXTERIOR WALL -BRICK ON 2X6
BRICK WITH WEEPS EVERY 16" O.C.
(SECURED TO FRAMING WITH GALV.
METAL TIES EVERY 16" O.C.), ON 1"
AIRSPACE, ON CONT. WEATHER
BARRIER , ON 1/2" EXT. GRADE GYPSUM
SHEATHING, ON 2X6 WD FRAMING AT 16"
O.C. WITH R-21 BATT INSULATION, ON
PTD. 1/2" GWB
EXTERIOR WALL -SIDING ON 2X8
HARDIPLANK SIDING ON WEATHER
BARRIER ON 3/4" EXT. GRADE PLY
SHEATHING ON 2X8 WD FRAMING ON
VAPOR BARRIER ON PTD. 1/2" GWB
(TYPICAL AT 1ST FL)
ALIGN INTERIOR FACE OF
2X6 AND 2X8 WD FRAMING
AT INTERIOR SIDE, TYP.
2' - 0"
FIRE-TREATED WD FRAMING
REQUIRED UP TO 2'-0",
MAINTAIN WHOLE FRAMING
PIECES BEYOND REQUIRED
AREAS
9' - 10 3/4"3-PLY 1 3/4" X 11 1/4" 2.0E LVL HEADER
WITH DBL JACKS WNDW HEADER
4-PLY 1 3/4" X 14" LVL HEADER
3-PLY 1 3/4" X 9 1/2" LVL HEADER2-PLY 1 3/4" X 9 1/2" HDR
(2) 2X10 9' - 11 1/2"OPEN TO BELOW
171 SF
LOUNGE
16
77 SF
OFFICE
17
31 SF
POWDER RM 1
18
273 SF
LIVING
11
203 SF
KITCHEN
13
428 SF
DINING
12
85 SF
PANTRY
14
68 SF
ENTRY
10
35 SF
PASSAGE 1
159' - 0 1/2"6' - 4 3/4"15' - 3"1' - 8 1/4"5' - 2 1/2"5' - 8 1/2"
FRPL
1
A300
1
A303
2
A303
CABINETRY PROVIDED
BY OTHERS
REFER TO INTERIOR
DESIGN DOCUMENTS
UNOCCUPIED
SPACE
UNDER STAIR
30
P32
P32
715' - 6"5' - 11"1
A3022
2
A300
13 SF
CLOSET
10A
35' - 7 3/4"
18' - 1"13' - 9 1/4"20' - 0 1/4"
CODE REQUIRED 1HR FIRE-RATED FIRE-
TREATED AND FIRE-RESISTANT
EXTERIOR WALL FRAMING, MATERIALS,
WINDOW OPENINGS, & ROOF
OVERHANG
2' - 0"
PATCH, REPAIR AND SEAL EXTG
BRICK WALL TO BE EXPOSED AT
INTERIOR SIDE, TYP.
VENT EXHAUST FOR
RANGE HOOD
WOOD HANDRAIL AT 3-0 HT., METAL 34
DIA. BALUSTERS SPACED AT 4 MIN. O.C.FULL EXTENT AT SIDE YARD30
NOTE:
1. EXPOSED BRICK WALL AT EXISTING
LOCATIONS. PATCH AND REPAIR GROUT IN
EXPOSED LOCATIONS. APPLY CLEAR
SEALER TO PROTECT SURFACES.
2. FOR INTERIOR FINISHES, CABINETRY,
FIXTURE SELECTIONS AND TRIMWORK,
REFER TO INTERIOR DWGS.
SOFFIT ABOVE FOR
MECH TO 2ND FL
4' - 5"
FRAMING PLAN NOTES FRAMING PLAN LEGEND
1. ALL DIMENSIONS ARE FROM FACE OF FRAMING U.O.N.
2. CONC. CONTRACTOR TO BE RESPONSIBLE FOR ALL CONC. CUTTING & REMOVAL.
3. THE CONTRACTOR SHALL VERIFY EXISTING AND FIELD CONDITIONS. THE CONTRACTOR SHALL
NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR REQUIRED MODIFICATIONS PRIOR TO
COMMENCING INSTALLATION OF EQUIPMENT AND ASSOCIATED WORK.
4. PROVIDE DOUBLE STUDS AT JAMBS OF ALL DOORS, WINDOWS AND SIMILAR OPENINGS.
5. ALL CONNECTORS USED IN PRESSURE-TREATED WOOD FRAMING SHALL BE STAINLESS OR
GALVANIZED STEEL.
6. ALL HEADERS, FLOOR JOISTS & RAFTERS ARE TO BE SPRUCE-PINE-FIR #2 OR BETTER, STUDS -
STUD GRADE
7. ALL HEADERS ARE TO BE 3-2X10'S UNLESS OTHERWISE SPECIFIED.
8. JOISTS:
A. SHALL BE SUPPORTED LATERALLY (TO PREVENT ROTATION) AT THE ENDS BY FULL DEPTH SOLID
BLOCKING NOT LESS THAN 2" NOMINAL THICKNESS OR BY ATTACHMENT TO HEADER, BAND, RIM
JOIST, OR TO AN ADJOINING STUD.
B. IN SEISMIC DESIGN CATEGORIES D1 AND D2, LATERAL RESTRAINT MUST BE PROVIDED AT EACH
INTERMEDIATE SUPPORT R502.7.
9. NOTCHING REQUIREMENTS FOR EXTERIOR LOAD BEARING WALLS:
A. LOAD BEARING WALLS CUT MORE THAN 50% MUST BE SECURED BY A METAL TIE .054 THICK BY 1
1/2 INCHES WIDE WITH 8-16D NAILS ON EACH SIDE EXCEPT WHERE EXTERIOR WALLS ARE
COVERED BY SHEATHING.
B. HOLES BETWEEN 40% AND 60% OF STUD DEPTH REQUIRE DOUBLE STUDS.
C. NO HOLES ARE PERMITTED WITHIN 5/8 INCH OF THE EDGE OF ANY STUD.
D. NO HOLES ARE PERMITTED WITHIN ON THE SAME CROSS SECTION AS A NOTCH ON ANY STUD.
E. NO NOTCHES ARE PERMITTED TO BE MORE THAN 25% OF THE STUD DEPTH . R502.8., 602.6(1).(2)
R602.6.1
10. ALL HEADERS, GIRDERS SUPPORTING BEAMS AND OTHER STRUCTURAL COMPONENTS ARE
COVERED UNDER R301.1.3 ENGINEERED DESIGN. THESE DRAWINGS HAVE BEEN PREPARED UNDER
THE DIRECT SUPERVISION AND SEALED BY A NEW YORK STATE CERTIFIED PROFESSIONAL
STRUCTURAL ENGINEER IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE (ASCE-7)
11. ALL TOP PLATES AND SILL PLATES SHALL BE #3 SYP OR DFL (19% MC) OR BETTER.
12. HEADERS, FLUSH BEAMS, AND DROP BEAMS SHALL BE #2 DFL OR SYP (19%MC) OR BETTER, U.O.N.
13. ALL HEADERS AND BEAMS SHALL HAVE DOUBLE STUD PACK UNDER EACH END, U.O.N.
14. SIMPSON CS20 X 48" LONG STRAPS SPACED AT 48" O.C. SHALL BE USED ALONG THE EXTERIOR OF
THE BUILDING CENTERED ACROSS THE FLOOR CAVITY.
15. THE STABILITY OF THE FLOOR IS NOT ACHEIVED UNTIL THE DECKING HAS BEEN PROPERLY
INSTALLED AND FASTENED.
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME TO REMAIN
NEW WALL
NEW DOOR
TYPE ID
W4
W4T
W6
PARTITION ASSEMBLY
1/2" GYP BD ON 2X4 WD FRAMING ON 1/2"
GYP BD, TYPICAL U.O.N.
1/2" GYP BD ON TURNED 2X4 WD FURRING
1/2" GYP BD ON 2X6 WD FRAMING ON 1/2"
GYP BD
WALLS WITH THIS SYMBOL INDICATE 3"
SOUND-ABSORBING INSULATION IS ADDED
FOR ACOUSTICAL INSULATION
DESIGN LOADS:
FIRST FLOOR
SECOND & ATTIC FLOOR
ROOF
LOADS:
40 PSF LIVE / 10 PSF DEAD
40 PSF LIVE / 10 PSF DEAD
50 PSF GROUND SNOW
47 PSF FLAT ROOF SNOW
20 PSF DEAD
115 MPH WIND
EXPOSURE: B
Scale
Project number
Date
devon telberg, aia
665 Saratoga Rd
Wilton, NY 12831
t (518) 212-7778
e devon@telbergstudio.com PROGRESS -NOT FOR CONSTRUCTI ON 8/12/2024 1:57:10 AMAs indicated
A101
First Floor Demolition & Proposed Plan
2404
The Bergman Residence 8/11/24
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
1/4" = 1'-0"1 First Floor Removals Plan
1/4" = 1'-0"2 First Floor Framing
No. Description Date
Door & Window Schedule
Type Mark Quantity Width Height Type Comments Manufacturer Model Glass Type
Daylight
Area
Heat Transfer
Coefficient (U)
Thermal Resistance
(R)Comments
D62 1 6' - 0 5/8" 6' - 10" Exterior 2DR Marvin UOFD2.25G2 6068 IG Low E II with Argon 24 SF
D164 1 13' - 11" 6' - 10" Exterior 2DR 2WN Marvin UOFDG2 14068 IG Low E II with Argon 58 SF
B60 1 5' - 0" 6' - 8" Interior BiFold 0 SF
D60 1 5' - 0" 6' - 8" Interior Double Panel 0 SF
P32 2 2' - 8" 6' - 8" Interior Pocket Panel 0 SF
30 6 2' - 6" 6' - 8" Interior Single Panel 0 SF 0.3865 BTU/(h·ft²·°F) 2.5873 (h·ft²·°F)/BTU
32 7 2' - 8" 6' - 8" Interior Single Panel 0 SF 0.3865 BTU/(h·ft²·°F) 2.5873 (h·ft²·°F)/BTU
36 2 3' - 0" 6' - 8" Interior Single Panel 0 SF 0.3865 BTU/(h·ft²·°F) 2.5873 (h·ft²·°F)/BTU
S60 3 5' - 0" 6' - 8" Interior Sliding 2-Panel 0 SF
82 SF
Window # Count Width Height Head Height Manufacturer Model
Visual Light
Transmittance
Daylight
Area
Vent
Area
Heat Transfer
Coefficient (U)
Thermal Resistance
(R)Comments
26 1 2' - 7" 5' - 10" 8' - 10" 0.81 0 SF 0 SF 0.5511
BTU/(h·ft²·°F)
1.8146 (h·ft²·°F)/BTU
33 1 3' - 0" 3' - 0" 6' - 6" 0 SF 0 SF
35 12 2' - 11 1/4" 4' - 11 1/2" 7' - 6" Marvin UDHG2 3042 119 SF 0 SF
36 3 2' - 11 1/4" 5' - 11 1/2" 9' - 0" Marvin UDHG2 3036 37 SF 0 SF
39 4 3' - 0" 8' - 9 1/8" 9' - 0" Marvin UCA3684 83 SF 80 SF
42 1 4' - 0" 2' - 6" 5' - 0" 0 SF 0 SF
43 2 4' - 0" 2' - 7 1/8" <varies> Marvin UFCA4832 13 SF 0 SF
Total: 252 SF 80 SF
1/4" = 1'-0"3 First Floor Proposed Plan
DN DN
UP
12
11
10
9
8
7
6
5
4
3
2
1
16 15 14 13
UP
W D
DN
3
A300
10' - 0 3/4"
3' - 5"
CUT AND REMOVE
FLOOR CONSTRUCTION
FOR NEW MECH SHAFT
OPENING, REFER TO
MECH CONTRACTOR
SCOPE FOR
COORDINATION
EXISTING STAIR TREAD
AND RISER TO REMAIN.
WALLS AND RAILINGS
TOBE REMOVED
REMOVE ADDITION COMPLETELY
REMOVE CHIMNEY FROM
BASEMENT TO ATTIC.
FROM ATTIC AND ABOVE,
EXISTING TO REMAIN
REMOVE EXTG
WINDOWS AND DOORS
ON WALLS TO BE
REMOVED, TYP.
REMOVE WINDOW DOWN TO
ROUGH OPENING, PATCH AND
REPAIR SUBSTRATE AS
REQUIRED FOR RECIEVING
NEW CONSTRUCTION
FASTENINGS
REMOVE ALL
PLUMBING FIXTURES
AND PIPES. ABANDON
PIPES IN PLACE WHERE
NOT IN CONFLICT WITH
NEW CONSTRUCTION,
TYP.
PATCH AND REPAIR
EXISTING WALL
CONSTRUCTION TO
RECEIVE NEW WALLS
AND FINISHES, TYP.
6' - 0"7' - 7"
4' - 0 1/4"6' - 6"3' - 0"7' - 6 3/4"4' - 2 1/2"2' - 0 1/2"3' - 0 1/2" CLR(11) T AT 10 3/4" EA9' - 10 1/4"LANDING3' - 1 1/2"3' - 7"2' - 1"6' - 10 1/2"7' - 2"13' - 3 1/4"7' - 3 1/2"15' - 2"5' - 6"4' - 11"2' - 4"9' - 0 3/4"0"NEW ADDITION5' - 0"11' - 4"8' - 8 3/4"15' - 2"
4"35' - 2 1/2" NEW ADDITION 6 1/2"
10' - 10 3/4"6' - 6"3' - 6 1/2"16' - 0 3/4"NEW ADDITION10' - 10 3/4"1' - 6"8' - 7 3/4"2' - 2"
4x4 WD COLUMN TO
SUPPORT ATTIC STRUC
FL AND STAIR FRAMING
ABOVE, TYP.NEW 2X10 AT 16" O.C.NEW 2X10 AT 16" O.C.W6
W4T
W6 W4T
W6
2' - 2 3/4"3' - 2"3' - 2"8' - 9 3/4"8' - 9 3/4"3' - 2"3' - 2"2' - 3"2' - 4"2' - 4"32
S6032323032
3232
D60
B60S60353535
35
33 35 35 35
35
1' - 0"EQ EQ
4' - 6"2' - 6"
EQ EQ
2' - 6"1' - 5 1/2"EQEQ1' - 6"4' - 6 1/2"3' - 9"1' - 7 1/4"5' - 3"
4' - 0 3/4"3' - 4 3/4"3' - 0 3/4"9' - 11 3/4"3' - 4"9 1/4"CL 2
28
PRIMARY BEDROOM
201
PRIMARY BATHROOM
202
WC 1
31
PRIMARY CLOSET
203
BEDROOM 3
209
BATHROOM 3
210
BEDROOM 2
206
PASSAGE 2204CL 3205BATHROOM 2
207
LAUNDRY RM208HALL
200
1' - 4"12' - 0 1/2"23' - 2"2' - 0"
3' - 0" D.O.
NEW STL LINTEL TO SUPPORT
BRICK WALL ABOVE, SECURE
TO 2ND FLOOR JOIST FRAMING
BELOW, SPAN OPENING BELOW
SECURE NEW WD FRAMING
THROUGH BRICK WITH BOLTS TO
EXTG WD FRAMING, TYP.
3' - 3" W
2' - 0"18" H BENCH
3' -6" H PARTIAL WALL
2' - 0"
FIRE-TREATED WD FRAMING
REQUIRED UP TO 2'-0", MAINTAIN
WHOLE FRAMING PIECES
BEYOND REQUIRED AREAS
NEW SHELF
NICHE
FLOOR TYPE 2
NEW FLOOR FINISH ON 1/2" PLY
SUBSTRATE ON 2x10 WD AT 16" O.C. ON
1/2" GWB
EXTERIOR WALL -SIDING ON 2X6
HARDIPLANK SIDING ON WEATHER
BARRIER ON 3/4" EXT. GRADE PLY
SHEATHING ON 2X6 WD FRAMING ON
VAPOR BARRIER ON PTD. 1/2" GWB .
VARIANCE REQUESTED IN ORDER TO
PROVIDE BOTTOM LANDING DEPTH AND
MID-LANDING STRUCTURAL SUPPORT
THAT AVOIDS EXISTING EXTERIOR
WINDOW LOCATION
CLR W
3' - 0 1/2"
(3) T AT 10 3/4" EA
2' - 8 1/4"
LANDING
3' - 3 1/2"
CLOSED STRINGER
SECURED TO EXTG WD
FRAMING, PROVIDE
ADDITIONAL WD
BLOCKING
OPEN CARRIAGE AT EXPOSED SIDE
3' - 0 1/2"NEW 2X10 WD FRAME FLOOR
INFILL FLUSH WITH EXTG
ADJACENT WD FRAMING
DEMOLITION NOTES
1. REMOVE DOOR AND FRAME SYSTEM COMPLETELY, REPAIR
ROUGH OPENING TO RECIEVE NEW DOOR OPENING
TRIMWORK
2. EXISTING MILLWORK AND APPLIANCES TO BE REMOVED
COMPLETE.
3. REMOVE EXISTING HEATING SYSTEMS COMPLETE.
4. ELEMENTS TO REMAIN IN PLACE SHALL BE PROTECTED
FROM DAMAGE, DUST AND DEBRIS.
5. CONTRACTOR TO MAINTAIN WATER TIGHT INTEGRITY OF
BUILDING AT ALL TIMES.
6. ALL FLOOR AND WALL CONDITIONS WHICH ARE TO RECEIVE
NEW CONSTRUCTION ARE TO BE DEMOLISHED AS INDICATED
AND PROPERLY PREPPED TO RECEIVE NEW FINISHES, U.O.N.
7. ALL FLOOR, WALL, AND CEILING CONDITIONS THAT ARE
DISTURBED BY DEMOLITION ARE TO BE PATCHED, REPAIRED
AND/OR PAINTED WITH SIMILAR MATERIALS. REFER TO
PROPOSED PLANS FOR LOCATIONS.
8. ALL ELECTRICAL REMOVALS TO BE PERFORMED BY A
LICENSED ELECTRICIAN.RELABEL PANELS. FOLLOW N.E.C.
(NFPA 70). PROVIDE THIRD-PARTY INSPECTION.
9. PRIOR TO COMMENCING REMOVALS WORK, AND UNTIL SUCH
TIME THAT FINAL WORK IS IN PLACE, CONTRACTOR SHALL
ASCERTAIN REQUIREMENTS FOR, AND PROVIDE, BRACING,
SHORING AND OTHER TEMPORARY SYSTEMS OF SUPPORT
NEEDED TO PREVENT DAMAGE TO EXISTING CONSTRUCTION
WHICH IS SCHEDULED TO REMAIN.
10. SHUT OFF, CAP AND OTHERWISE PROTECT EXISTING
UTILITIES IN STRICT ACCORDANCE WITH THE REQUIREMENTS
OF THE PUBLIC AGENCIES OR UTILITIES HAVING
JURISDICTION AND AS DIRECTED ON THE MECHANICAL AND
ELECTRICAL DRAWINGS.
11. COMPLETELY REMOVE ITEMS SCHEDULED TO BE
DEMOLISHED AND REMOVED, LEAVING SURFACES CLEAN,
SOLID AND READY TO RECEIVE NEW MATERIALS SPECIFIED
ELSEWHERE.
12. DEMOLISHED MATERIALS SHALL BE COMPLETELY REMOVED
FROM THE JOB SITE AND DISPOSED OF PROPERLY UNLESS
OTHERWISE DIRECTED BY OWNER.
13. ALL EXISTING ITEMS SCHEDULED TO REMAIN SHALL BE
FULLY PROTECTED FROM ANY DELETERIOUS EFFECT
DURING ALL PHASES OF THE PROJECT. ANY DAMAGE TO
EXISTING ITEMS (WHETHER THEY ARE SHOWN ON THE
DRAWINGS OR NOT) SHALL BE CORRECTED TO THE
SATISFACTION OF THE OWNER AT THE EXPENSE OF THE
CONTRACTOR.
DEMOLITION LEGEND
EXISTING WALL TO BE REMOVED
EXISTING DOOR AND FRAME TO BE REMOVED
EXISTING WALL TO REMAIN
EXISTING DOOR TO REMAIN
14. ALL REMOVALS INDICATED MAY REQUIRE THE
COORDINATED REMOVAL OF EXISTING MECHANICAL,
ELECTRICAL, SECURITY SYSTEM, FIRE ALARM SYSTEM,
DATA AND TELEPHONE SYSTEM AND PLUMBING
EQUIPMENT AND LINES -REFER TO MECHANICAL AND
ELECTRICAL CONTRACTORS FOR INFORMATION
REGARDING EXISTING AND NEW H.V.A.C., PLUMBING,
ELECTRICAL ETC., RELATED WORK PRIOR TO
COMMENCING DEMOLITION.
15. COORDINATE ALL PARTIAL PARTITION REMOVAL
DIMENSIONS WITH FLOOR PLAN PRIOR TO DEMOLITION
TAKING PLACE.
16. REMOVE ALL ABANDONED PIPING, WIRING, EQUIPMENT,
LIGHTING, DUCTWORK, TUBING, SUPPORTS, FIXTURES,
ETC., BACK TO ITS ORIGINATION POINT, IN ITS ENTIRETY.
VISIT EACH ROOM, CRAWL SPACE, ROOF, AND BUILDING
EXTERIOR TO DETERMINE TOTAL SCOPE OF WORK.
17. DISCONNECT, REMOVE, RELOCATE AND PERMANENTLY
RECONNECT ANY AND ALL EXISTING MECHANICAL AND
ELECTRICAL WORK THAT IS REQUIRED TO REMAIN, BUT
INTERFERING WITH NEW CONSTRUCTION.
18. THE CONTRACTOR SHALL NOT LEAVE, ABANDONED,
PIPING, DUCTWORK, CONDUIT OR OUTLET BOXES IN
PLACE, EXCEPT THOSE ABANDONED ITEMS
PERMANENTLY BURIED AND CONCEALED IN EXISTING
WALLS AND FLOORS. THE CONTRACTOR SHALL REMOVE
ALL EXISTING EXPOSED AND ABANDONED PIPING,
DUCTWORK, OUTLET BOXES, CONDUITS, ETC., EVEN
THOSE ABANDONED ABOVE EXISTING CEILINGS, IN
EITHER RENOVATED AREAS, OR IN AREAS NOT BEING
RENOVATED. THOSE LEFT ABANDONED WITHIN EITHER
EXISTING WALLS OR FLOORS, SHALL BE CUT OFF AT THE
POINT WHERE THEY EXIT WALL OR FLOOR, CAPPED AND
COVERED FLUSH.
19. EXISTING EQUIPMENT CONNECTIONS AND WIRING
DEVICES, SCHEDULED FOR RELOCATION, SHALL BE
EXTENDED TO NEW LOCATION UTILIZING THE SAME
MATERIALS AND METHODS PREVIOUSLY USED.
(EXAMPLE: IF EXISTING WIRING DEVICE OUTLET WAS
PREVIOUSLY INSTALLED WITH GALVANIZED RIGID STEEL
CONDUIT, NEW RELOCATED OUTLET SHALL BE EXTENDED
WITH NEW GALVANIZED RIGID STEEL CONDUIT.)
1
A300
1
A303
2
A303
1
A3022
2
A300
NOTE:
1. EXPOSED BRICK WALL AT EXISTING
LOCATIONS. PATCH AND REPAIR GROUT IN
EXPOSED LOCATIONS. APPLY CLEAR
SEALER TO PROTECT SURFACES.
2. FOR INTERIOR FINISHES, CABINETRY,
FIXTURE SELECTIONS AND TRIMWORK,
REFER TO INTERIOR DWGS.ALIGN3232B6032
32
32
D60
32
12 SF
CL 2
28
200 SF
PRIMARY BEDROOM
201
141 SF
PRIMARY BATHROOM
202
18 SF
WC 1
31
115 SF
PRIMARY CLOSET
203
161 SF
BEDROOM 3
209
66 SF
BATHROOM 3
210 145 SF
BEDROOM 2
206
24 SFPASSAGE 220412 SFCL 320558 SF
BATHROOM 2
207
34 SF
LAUNDRY RM
208
217 SF
HALL
200
30PARTIAL HEIGHT WALL
UP TO 3'-0" AFF
SHOWER BENCH
AT 1'-8" HT AFF
SHOWER PAN 60" X 36"
FULL HT SHELVING
SHELVING BELOW
WINDOW SILL
BENCH
TYPICAL ROD & SHELF S60S6035 35 35
35
33 35 35 35
35
PATH FOR
NEW ATTIC
PLUMBING
ABOVE1/2" / 12"3" / 12"CODE REQUIRED 1HR FIRE-RATED FIRE-
TREATED AND FIRE-RESISTANT
EXTERIOR WALL FRAMING, MATERIALS,
WINDOW OPENINGS, & ROOF
OVERHANG
2' - 0"FULL EXTENT AT SIDE YARDLINE OF FACE OF FACADE BELOW
TRIM NEW WD COL.
FULL HT SHELVING
WITH CABINETRY
DOORS
FRAMING PLAN NOTES FRAMING PLAN LEGEND
1. ALL DIMENSIONS ARE FROM FACE OF FRAMING U.O.N.
2. CONC. CONTRACTOR TO BE RESPONSIBLE FOR ALL CONC. CUTTING & REMOVAL.
3. THE CONTRACTOR SHALL VERIFY EXISTING AND FIELD CONDITIONS. THE CONTRACTOR SHALL
NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR REQUIRED MODIFICATIONS PRIOR TO
COMMENCING INSTALLATION OF EQUIPMENT AND ASSOCIATED WORK.
4. PROVIDE DOUBLE STUDS AT JAMBS OF ALL DOORS, WINDOWS AND SIMILAR OPENINGS.
5. ALL CONNECTORS USED IN PRESSURE-TREATED WOOD FRAMING SHALL BE STAINLESS OR
GALVANIZED STEEL.
6. ALL HEADERS, FLOOR JOISTS & RAFTERS ARE TO BE SPRUCE-PINE-FIR #2 OR BETTER, STUDS -
STUD GRADE
7. ALL HEADERS ARE TO BE 3-2X10'S UNLESS OTHERWISE SPECIFIED.
8. JOISTS:
A. SHALL BE SUPPORTED LATERALLY (TO PREVENT ROTATION) AT THE ENDS BY FULL DEPTH SOLID
BLOCKING NOT LESS THAN 2" NOMINAL THICKNESS OR BY ATTACHMENT TO HEADER, BAND, RIM
JOIST, OR TO AN ADJOINING STUD.
B. IN SEISMIC DESIGN CATEGORIES D1 AND D2, LATERAL RESTRAINT MUST BE PROVIDED AT EACH
INTERMEDIATE SUPPORT R502.7.
9. NOTCHING REQUIREMENTS FOR EXTERIOR LOAD BEARING WALLS:
A. LOAD BEARING WALLS CUT MORE THAN 50% MUST BE SECURED BY A METAL TIE .054 THICK BY 1
1/2 INCHES WIDE WITH 8-16D NAILS ON EACH SIDE EXCEPT WHERE EXTERIOR WALLS ARE
COVERED BY SHEATHING.
B. HOLES BETWEEN 40% AND 60% OF STUD DEPTH REQUIRE DOUBLE STUDS.
C. NO HOLES ARE PERMITTED WITHIN 5/8 INCH OF THE EDGE OF ANY STUD.
D. NO HOLES ARE PERMITTED WITHIN ON THE SAME CROSS SECTION AS A NOTCH ON ANY STUD.
E. NO NOTCHES ARE PERMITTED TO BE MORE THAN 25% OF THE STUD DEPTH . R502.8., 602.6(1).(2)
R602.6.1
10. ALL HEADERS, GIRDERS SUPPORTING BEAMS AND OTHER STRUCTURAL COMPONENTS ARE
COVERED UNDER R301.1.3 ENGINEERED DESIGN. THESE DRAWINGS HAVE BEEN PREPARED UNDER
THE DIRECT SUPERVISION AND SEALED BY A NEW YORK STATE CERTIFIED PROFESSIONAL
STRUCTURAL ENGINEER IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE (ASCE-7)
11. ALL TOP PLATES AND SILL PLATES SHALL BE #3 SYP OR DFL (19% MC) OR BETTER.
12. HEADERS, FLUSH BEAMS, AND DROP BEAMS SHALL BE #2 DFL OR SYP (19%MC) OR BETTER, U.O.N.
13. ALL HEADERS AND BEAMS SHALL HAVE DOUBLE STUD PACK UNDER EACH END, U.O.N.
14. SIMPSON CS20 X 48" LONG STRAPS SPACED AT 48" O.C. SHALL BE USED ALONG THE EXTERIOR OF
THE BUILDING CENTERED ACROSS THE FLOOR CAVITY.
15. THE STABILITY OF THE FLOOR IS NOT ACHEIVED UNTIL THE DECKING HAS BEEN PROPERLY
INSTALLED AND FASTENED.
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME TO REMAIN
NEW WALL
NEW DOOR
TYPE ID
W4
W4T
W6
PARTITION ASSEMBLY
1/2" GYP BD ON 2X4 WD FRAMING ON 1/2"
GYP BD, TYPICAL U.O.N.
1/2" GYP BD ON TURNED 2X4 WD FURRING
1/2" GYP BD ON 2X6 WD FRAMING ON 1/2"
GYP BD
WALLS WITH THIS SYMBOL INDICATE 3"
SOUND-ABSORBING INSULATION IS ADDED
FOR ACOUSTICAL INSULATION
DESIGN LOADS:
FIRST FLOOR
SECOND & ATTIC FLOOR
ROOF
LOADS:
40 PSF LIVE / 10 PSF DEAD
40 PSF LIVE / 10 PSF DEAD
50 PSF GROUND SNOW
47 PSF FLAT ROOF SNOW
20 PSF DEAD
115 MPH WIND
EXPOSURE: B
Scale
Project number
Date
devon telberg, aia
665 Saratoga Rd
Wilton, NY 12831
t (518) 212-7778
e devon@telbergstudio.com PROGRESS -NOT FOR CONSTRUCTI ON 8/12/2024 1:57:11 AMAs indicated
A102
Second Floor Removals & Framing Plan
2404
The Bergman Residence 8/11/24
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
1/4" = 1'-0"1 Second Floor Removals Plan
PROGRESS -NOT FOR CONSTRUCTI ON
1/4" = 1'-0"2 Second Floor Framing Plan
No. Description Date
Door & Window Schedule
Type Mark Quantity Width Height Type Comments Manufacturer Model Glass Type
Daylight
Area
Heat Transfer
Coefficient (U)
Thermal Resistance
(R)Comments
D62 1 6' - 0 5/8" 6' - 10" Exterior 2DR Marvin UOFD2.25G2 6068 IG Low E II with Argon 24 SF
D164 1 13' - 11" 6' - 10" Exterior 2DR 2WN Marvin UOFDG2 14068 IG Low E II with Argon 58 SF
B60 1 5' - 0" 6' - 8" Interior BiFold 0 SF
D60 1 5' - 0" 6' - 8" Interior Double Panel 0 SF
P32 2 2' - 8" 6' - 8" Interior Pocket Panel 0 SF
30 6 2' - 6" 6' - 8" Interior Single Panel 0 SF 0.3865 BTU/(h·ft²·°F) 2.5873 (h·ft²·°F)/BTU
32 7 2' - 8" 6' - 8" Interior Single Panel 0 SF 0.3865 BTU/(h·ft²·°F) 2.5873 (h·ft²·°F)/BTU
36 2 3' - 0" 6' - 8" Interior Single Panel 0 SF 0.3865 BTU/(h·ft²·°F) 2.5873 (h·ft²·°F)/BTU
S60 3 5' - 0" 6' - 8" Interior Sliding 2-Panel 0 SF
82 SF
Window # Count Width Height Head Height Manufacturer Model
Visual Light
Transmittance
Daylight
Area
Vent
Area
Heat Transfer
Coefficient (U)
Thermal Resistance
(R)Comments
26 1 2' - 7" 5' - 10" 8' - 10" 0.81 0 SF 0 SF 0.5511
BTU/(h·ft²·°F)
1.8146 (h·ft²·°F)/BTU
33 1 3' - 0" 3' - 0" 6' - 6" 0 SF 0 SF
35 12 2' - 11 1/4" 4' - 11 1/2" 7' - 6" Marvin UDHG2 3042 119 SF 0 SF
36 3 2' - 11 1/4" 5' - 11 1/2" 9' - 0" Marvin UDHG2 3036 37 SF 0 SF
39 4 3' - 0" 8' - 9 1/8" 9' - 0" Marvin UCA3684 83 SF 80 SF
42 1 4' - 0" 2' - 6" 5' - 0" 0 SF 0 SF
43 2 4' - 0" 2' - 7 1/8" <varies> Marvin UFCA4832 13 SF 0 SF
Total: 252 SF 80 SF
1/4" = 1'-0"3 Second Floor Proposed Plan
DN
W D
16 15 14 13
12
11
10
9
8
7
6
5
4
3
3
A300
1
A301
6' - 3 1/4"
REMOVE ROOF,
RAFTERS,
CORNICE TRIM AT
AREA TO RECEIVE
NEW DORMER AT
NEW STAIR
CUT FRAMING AND
CEILING BELOW FOR
NEW OPENING AT
NEW STAIR
CUT AND REMOVE
EXTERIOR BRICK
WALL TO RECEIVE
NEW DOOR
REMOVE INTERIOR CHIMNEY WALLS
COMPLETE. PATCH AND REPAIR
EXTERIOR WALL FOR ACHIEVING GOOD
CONDITION
EXISTING CHIMNEY TO REMAIN
UNOCCUPIED
SPACE
UNOCCUPIED
SPACE
12' - 7 3/4"4' - 8 3/4"3' - 11 1/4"3' - 3 3/4"2' - 10"8' - 8"4' - 8 3/4"WALLS UNDER LOW
ROOF AREAS, TYP
26 SF
BATH
211
463 SF
GREAT ROOM
212
BEDROOM 4
213 CL 4214UNOCCUPIED
SPACE
UNOCCUPIED
SPACE
5' - 9 1/4"3' - 4"5' - 9"7' - 5 1/4"3' - 2 1/2"12' - 6 1/2"4' - 10"EQ EQ
ALIGN
NEW WINDOW OPENING IN
EXTG EXT. WALL, DBL. 2X10
HEADER
ALIGN FACE OF NEW VERTICAL
WALLS AT LOCATIONS WHERE
SLOPED HEAD HT IS 4'-0" AFF, TYP.D6243
4342
30
30
30
EXISTING TO REMAINNEW ADDITION11' - 0 3/4"ALIGNFRAME NEW STAIR
OPENING & TOP LANDING
NEW SPF 2X10
AT 16" O.C.NEW SPF 2X10 AT 16" O.C.NEW SPF 2X10 AT 16" O.C.DBL. 2X10 HEADERS
AT ALL NEW DOOR
AND WINDOW
OPENINGS, TYP.<varies>
(2) STUDS E.E.
(2) STUDS E.E.
NEW DOOR OPENING IN
EXTG EXT. WALL. NEW
STL LINTEL TO SUPPORT
BRICK WALL ABOVE
13' - 4 1/4"7' - 5 1/2"
POSTS AT FLOOR BELOW
ROOF TYPE 3 (DECK)
1x4 TREX DECKING ON PRESSURE-TRD
WD SLEEPERS ON TPO MEMBRANE
FULLY ADHERED WITH HEAT-WELDED
SEAMS ON 5/8" THK COVER BOARD ON
R-10 (MIN. 2") RIGID INSULATION ON 3/4"
THK EXTERIOR GRADE PLY SHEATHING
ON WD FRAMING
3' -6" H 1 1/2" DIA. GUARDRAIL,
TENSION CABLE (SPACED 4" MAX. O.C.),
1 1/2" DIA. POSTS SECURED WITH
GALV. STL ANGLES TO ROOF JOISTS
STRUC FRAMING BELOW
3' - 0 3/4"3' - 0"3' - 3 1/2"
1' - 10"
2' - 1"4 1/4"WALLS UNDER LOW
ROOF AREAS, TYP
3' - 11 1/2"4' - 7 1/4"3' - 11 1/2"EXTERIOR WALL -SIDING ON 2X8
HARDIPLANK SIDING ON WEATHER
BARRIER ON 3/4" EXT. GRADE PLY
SHEATHING ON 2X8 WD FRAMING ON
VAPOR BARRIER ON PTD. 1/2" GWB
(TYPICAL AT 1ST FL)
1
A300
1
A303
2
A303
1
A301
1
A3022
2
A300
26 SF
BATH
211
463 SF
GREAT ROOM
212
165 SF
BEDROOM 4
213 12 SFCL 4214UNOCCUPIED
SPACE
UNOCCUPIED
SPACE D6230
42
3030 43
43
3' - 0 1/2"
CODE REQUIRED
1HR FIRE-RATED
EXTERIOR WALL &
WINDOW OPENINGS
CODE REQUIRED
1HR FIRE-RATED
EXTERIOR WALL,
WINDOW OPENINGS,
&FIRE-TREATED
WOOD OVERHANG
2' - 0"1' - 11"
ROOF TYPE 1 (TPO)
TPO MEMBRANE ADHERED TO 7/16" OSB
EXT. GRADE COVER BOARD ON
TAPERED R-10 RIGID INSULATION (MIN.
2") ON CONT. VAPOR RETARDER ON 1/2"
EXT. GRADE PLY SHEATHING ON 2X10
WD FRAMING WITH R-33 BATT
INSULATION
ROOF TYPE 4 (ASPHALT) 1HR FIRE-RATED
ASPHALT SHINGLE ON ROOFING PAPER
ON 3/4" EXT. GRADE PLY SHEATHING ON
2X10 WD FRAMING FILLED WITH R-38
BATT INSULATION
WALLS UNDER LOW
ROOF AREAS, TYP
VENT THROUGH ROOF
DEMOLITION NOTES
1. REMOVE DOOR AND FRAME SYSTEM COMPLETELY, REPAIR
ROUGH OPENING TO RECIEVE NEW DOOR OPENING
TRIMWORK
2. EXISTING MILLWORK AND APPLIANCES TO BE REMOVED
COMPLETE.
3. REMOVE EXISTING HEATING SYSTEMS COMPLETE.
4. ELEMENTS TO REMAIN IN PLACE SHALL BE PROTECTED
FROM DAMAGE, DUST AND DEBRIS.
5. CONTRACTOR TO MAINTAIN WATER TIGHT INTEGRITY OF
BUILDING AT ALL TIMES.
6. ALL FLOOR AND WALL CONDITIONS WHICH ARE TO RECEIVE
NEW CONSTRUCTION ARE TO BE DEMOLISHED AS INDICATED
AND PROPERLY PREPPED TO RECEIVE NEW FINISHES, U.O.N.
7. ALL FLOOR, WALL, AND CEILING CONDITIONS THAT ARE
DISTURBED BY DEMOLITION ARE TO BE PATCHED, REPAIRED
AND/OR PAINTED WITH SIMILAR MATERIALS. REFER TO
PROPOSED PLANS FOR LOCATIONS.
8. ALL ELECTRICAL REMOVALS TO BE PERFORMED BY A
LICENSED ELECTRICIAN.RELABEL PANELS. FOLLOW N.E.C.
(NFPA 70). PROVIDE THIRD-PARTY INSPECTION.
9. PRIOR TO COMMENCING REMOVALS WORK, AND UNTIL SUCH
TIME THAT FINAL WORK IS IN PLACE, CONTRACTOR SHALL
ASCERTAIN REQUIREMENTS FOR, AND PROVIDE, BRACING,
SHORING AND OTHER TEMPORARY SYSTEMS OF SUPPORT
NEEDED TO PREVENT DAMAGE TO EXISTING CONSTRUCTION
WHICH IS SCHEDULED TO REMAIN.
10. SHUT OFF, CAP AND OTHERWISE PROTECT EXISTING
UTILITIES IN STRICT ACCORDANCE WITH THE REQUIREMENTS
OF THE PUBLIC AGENCIES OR UTILITIES HAVING
JURISDICTION AND AS DIRECTED ON THE MECHANICAL AND
ELECTRICAL DRAWINGS.
11. COMPLETELY REMOVE ITEMS SCHEDULED TO BE
DEMOLISHED AND REMOVED, LEAVING SURFACES CLEAN,
SOLID AND READY TO RECEIVE NEW MATERIALS SPECIFIED
ELSEWHERE.
12. DEMOLISHED MATERIALS SHALL BE COMPLETELY REMOVED
FROM THE JOB SITE AND DISPOSED OF PROPERLY UNLESS
OTHERWISE DIRECTED BY OWNER.
13. ALL EXISTING ITEMS SCHEDULED TO REMAIN SHALL BE
FULLY PROTECTED FROM ANY DELETERIOUS EFFECT
DURING ALL PHASES OF THE PROJECT. ANY DAMAGE TO
EXISTING ITEMS (WHETHER THEY ARE SHOWN ON THE
DRAWINGS OR NOT) SHALL BE CORRECTED TO THE
SATISFACTION OF THE OWNER AT THE EXPENSE OF THE
CONTRACTOR.
DEMOLITION LEGEND
EXISTING WALL TO BE REMOVED
EXISTING DOOR AND FRAME TO BE REMOVED
EXISTING WALL TO REMAIN
EXISTING DOOR TO REMAIN
14. ALL REMOVALS INDICATED MAY REQUIRE THE
COORDINATED REMOVAL OF EXISTING MECHANICAL,
ELECTRICAL, SECURITY SYSTEM, FIRE ALARM SYSTEM,
DATA AND TELEPHONE SYSTEM AND PLUMBING
EQUIPMENT AND LINES -REFER TO MECHANICAL AND
ELECTRICAL CONTRACTORS FOR INFORMATION
REGARDING EXISTING AND NEW H.V.A.C., PLUMBING,
ELECTRICAL ETC., RELATED WORK PRIOR TO
COMMENCING DEMOLITION.
15. COORDINATE ALL PARTIAL PARTITION REMOVAL
DIMENSIONS WITH FLOOR PLAN PRIOR TO DEMOLITION
TAKING PLACE.
16. REMOVE ALL ABANDONED PIPING, WIRING, EQUIPMENT,
LIGHTING, DUCTWORK, TUBING, SUPPORTS, FIXTURES,
ETC., BACK TO ITS ORIGINATION POINT, IN ITS ENTIRETY.
VISIT EACH ROOM, CRAWL SPACE, ROOF, AND BUILDING
EXTERIOR TO DETERMINE TOTAL SCOPE OF WORK.
17. DISCONNECT, REMOVE, RELOCATE AND PERMANENTLY
RECONNECT ANY AND ALL EXISTING MECHANICAL AND
ELECTRICAL WORK THAT IS REQUIRED TO REMAIN, BUT
INTERFERING WITH NEW CONSTRUCTION.
18. THE CONTRACTOR SHALL NOT LEAVE, ABANDONED,
PIPING, DUCTWORK, CONDUIT OR OUTLET BOXES IN
PLACE, EXCEPT THOSE ABANDONED ITEMS
PERMANENTLY BURIED AND CONCEALED IN EXISTING
WALLS AND FLOORS. THE CONTRACTOR SHALL REMOVE
ALL EXISTING EXPOSED AND ABANDONED PIPING,
DUCTWORK, OUTLET BOXES, CONDUITS, ETC., EVEN
THOSE ABANDONED ABOVE EXISTING CEILINGS, IN
EITHER RENOVATED AREAS, OR IN AREAS NOT BEING
RENOVATED. THOSE LEFT ABANDONED WITHIN EITHER
EXISTING WALLS OR FLOORS, SHALL BE CUT OFF AT THE
POINT WHERE THEY EXIT WALL OR FLOOR, CAPPED AND
COVERED FLUSH.
19. EXISTING EQUIPMENT CONNECTIONS AND WIRING
DEVICES, SCHEDULED FOR RELOCATION, SHALL BE
EXTENDED TO NEW LOCATION UTILIZING THE SAME
MATERIALS AND METHODS PREVIOUSLY USED.
(EXAMPLE: IF EXISTING WIRING DEVICE OUTLET WAS
PREVIOUSLY INSTALLED WITH GALVANIZED RIGID STEEL
CONDUIT, NEW RELOCATED OUTLET SHALL BE EXTENDED
WITH NEW GALVANIZED RIGID STEEL CONDUIT.)
FRAMING PLAN NOTES FRAMING PLAN LEGEND
1. ALL DIMENSIONS ARE FROM FACE OF FRAMING U.O.N.
2. CONC. CONTRACTOR TO BE RESPONSIBLE FOR ALL CONC. CUTTING & REMOVAL.
3. THE CONTRACTOR SHALL VERIFY EXISTING AND FIELD CONDITIONS. THE CONTRACTOR SHALL
NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR REQUIRED MODIFICATIONS PRIOR TO
COMMENCING INSTALLATION OF EQUIPMENT AND ASSOCIATED WORK.
4. PROVIDE DOUBLE STUDS AT JAMBS OF ALL DOORS, WINDOWS AND SIMILAR OPENINGS.
5. ALL CONNECTORS USED IN PRESSURE-TREATED WOOD FRAMING SHALL BE STAINLESS OR
GALVANIZED STEEL.
6. ALL HEADERS, FLOOR JOISTS & RAFTERS ARE TO BE SPRUCE-PINE-FIR #2 OR BETTER, STUDS -
STUD GRADE
7. ALL HEADERS ARE TO BE 3-2X10'S UNLESS OTHERWISE SPECIFIED.
8. JOISTS:
A. SHALL BE SUPPORTED LATERALLY (TO PREVENT ROTATION) AT THE ENDS BY FULL DEPTH SOLID
BLOCKING NOT LESS THAN 2" NOMINAL THICKNESS OR BY ATTACHMENT TO HEADER, BAND, RIM
JOIST, OR TO AN ADJOINING STUD.
B. IN SEISMIC DESIGN CATEGORIES D1 AND D2, LATERAL RESTRAINT MUST BE PROVIDED AT EACH
INTERMEDIATE SUPPORT R502.7.
9. NOTCHING REQUIREMENTS FOR EXTERIOR LOAD BEARING WALLS:
A. LOAD BEARING WALLS CUT MORE THAN 50% MUST BE SECURED BY A METAL TIE .054 THICK BY 1
1/2 INCHES WIDE WITH 8-16D NAILS ON EACH SIDE EXCEPT WHERE EXTERIOR WALLS ARE
COVERED BY SHEATHING.
B. HOLES BETWEEN 40% AND 60% OF STUD DEPTH REQUIRE DOUBLE STUDS.
C. NO HOLES ARE PERMITTED WITHIN 5/8 INCH OF THE EDGE OF ANY STUD.
D. NO HOLES ARE PERMITTED WITHIN ON THE SAME CROSS SECTION AS A NOTCH ON ANY STUD.
E. NO NOTCHES ARE PERMITTED TO BE MORE THAN 25% OF THE STUD DEPTH . R502.8., 602.6(1).(2)
R602.6.1
10. ALL HEADERS, GIRDERS SUPPORTING BEAMS AND OTHER STRUCTURAL COMPONENTS ARE
COVERED UNDER R301.1.3 ENGINEERED DESIGN. THESE DRAWINGS HAVE BEEN PREPARED UNDER
THE DIRECT SUPERVISION AND SEALED BY A NEW YORK STATE CERTIFIED PROFESSIONAL
STRUCTURAL ENGINEER IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE (ASCE-7)
11. ALL TOP PLATES AND SILL PLATES SHALL BE #3 SYP OR DFL (19% MC) OR BETTER.
12. HEADERS, FLUSH BEAMS, AND DROP BEAMS SHALL BE #2 DFL OR SYP (19%MC) OR BETTER, U.O.N.
13. ALL HEADERS AND BEAMS SHALL HAVE DOUBLE STUD PACK UNDER EACH END, U.O.N.
14. SIMPSON CS20 X 48" LONG STRAPS SPACED AT 48" O.C. SHALL BE USED ALONG THE EXTERIOR OF
THE BUILDING CENTERED ACROSS THE FLOOR CAVITY.
15. THE STABILITY OF THE FLOOR IS NOT ACHEIVED UNTIL THE DECKING HAS BEEN PROPERLY
INSTALLED AND FASTENED.
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME TO REMAIN
NEW WALL
NEW DOOR
TYPE ID
W4
W4T
W6
PARTITION ASSEMBLY
1/2" GYP BD ON 2X4 WD FRAMING ON 1/2"
GYP BD, TYPICAL U.O.N.
1/2" GYP BD ON TURNED 2X4 WD FURRING
1/2" GYP BD ON 2X6 WD FRAMING ON 1/2"
GYP BD
WALLS WITH THIS SYMBOL INDICATE 3"
SOUND-ABSORBING INSULATION IS ADDED
FOR ACOUSTICAL INSULATION
DESIGN LOADS:
FIRST FLOOR
SECOND & ATTIC FLOOR
ROOF
LOADS:
40 PSF LIVE / 10 PSF DEAD
40 PSF LIVE / 10 PSF DEAD
50 PSF GROUND SNOW
47 PSF FLAT ROOF SNOW
20 PSF DEAD
115 MPH WIND
EXPOSURE: B
Scale
Project number
Date
devon telberg, aia
665 Saratoga Rd
Wilton, NY 12831
t (518) 212-7778
e devon@telbergstudio.com PROGRESS -NOT FOR CONSTRUCTI ON 8/12/2024 1:57:13 AMAs indicated
A103
Attic Demolition & Proposed Plan
2404
The Bergman Residence 8/11/24
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
1/4" = 1'-0"2 Attic Floor Removals Plan
1/4" = 1'-0"1 Attic Floor Framing Plan
No. Description Date
1/4" = 1'-0"3 Attic Floor Proposed Plan
Door & Window Schedule
Type Mark Quantity Width Height Type Comments Manufacturer Model Glass Type
Daylight
Area
Heat Transfer
Coefficient (U)
Thermal Resistance
(R)Comments
D62 1 6' - 0 5/8" 6' - 10" Exterior 2DR Marvin UOFD2.25G2 6068 IG Low E II with Argon 24 SF
D164 1 13' - 11" 6' - 10" Exterior 2DR 2WN Marvin UOFDG2 14068 IG Low E II with Argon 58 SF
B60 1 5' - 0" 6' - 8" Interior BiFold 0 SF
D60 1 5' - 0" 6' - 8" Interior Double Panel 0 SF
P32 2 2' - 8" 6' - 8" Interior Pocket Panel 0 SF
30 6 2' - 6" 6' - 8" Interior Single Panel 0 SF 0.3865 BTU/(h·ft²·°F) 2.5873 (h·ft²·°F)/BTU
32 7 2' - 8" 6' - 8" Interior Single Panel 0 SF 0.3865 BTU/(h·ft²·°F) 2.5873 (h·ft²·°F)/BTU
36 2 3' - 0" 6' - 8" Interior Single Panel 0 SF 0.3865 BTU/(h·ft²·°F) 2.5873 (h·ft²·°F)/BTU
S60 3 5' - 0" 6' - 8" Interior Sliding 2-Panel 0 SF
82 SF
Window # Count Width Height Head Height Manufacturer Model
Visual Light
Transmittance
Daylight
Area
Vent
Area
Heat Transfer
Coefficient (U)
Thermal Resistance
(R)Comments
26 1 2' - 7" 5' - 10" 8' - 10" 0.81 0 SF 0 SF 0.5511
BTU/(h·ft²·°F)
1.8146 (h·ft²·°F)/BTU
33 1 3' - 0" 3' - 0" 6' - 6" 0 SF 0 SF
35 12 2' - 11 1/4" 4' - 11 1/2" 7' - 6" Marvin UDHG2 3042 119 SF 0 SF
36 3 2' - 11 1/4" 5' - 11 1/2" 9' - 0" Marvin UDHG2 3036 37 SF 0 SF
39 4 3' - 0" 8' - 9 1/8" 9' - 0" Marvin UCA3684 83 SF 80 SF
42 1 4' - 0" 2' - 6" 5' - 0" 0 SF 0 SF
43 2 4' - 0" 2' - 7 1/8" <varies> Marvin UFCA4832 13 SF 0 SF
Total: 252 SF 80 SF
2
A300
12' - 7 3/4" VIF4' - 10 1/2" VIF
12" / 12"12" / 12"
12" / 12"12" / 12"12" / 12"12" / 12"8" / 12"8" / 12"
EXISTING ADDITION ROOF TO
BE REMOVED COMPLETELY
EXISTING ROOF AREA TO BE
REMOVED, VERIFY IN FIELD
AND COORDINATE WITH
PLANS AT NEW DORMER
FOUNDATION, COLUMNS, WALLS, DOORS, STAIRS, ROOFS
REMOVE EXTG ADDITION CONSTRUCTION ENTIRELY:
EXISTING ROOF AREAS TO REMAIN
REMOVE CHIMNEY
COMPLETELY, PATCH AND
REPAIR ROOF , TYP.
12" / 12"12" / 12"
12" / 12"12" / 12"
3" / 12"1/4" / 12"1/2" / 12"3" / 12"12" / 12"12" / 12"8" / 12"8" / 12"
ROOF TYPE 3 (DECK)
1x4 TREX DECKING ON PRESSURE-TRD
WD SLEEPERS ON TPO MEMBRANE
FULLY ADHERED WITH HEAT-WELDED
SEAMS ON 5/8" THK COVER BOARD ON
R-10 (MIN. 2") RIGID INSULATION ON 3/4"
THK EXTERIOR GRADE PLY SHEATHING
ON WD FRAMING
ROOF TYPE 1 (TPO)
TPO MEMBRANE ADHERED TO 7/16" OSB
EXT. GRADE COVER BOARD ON
TAPERED R-10 RIGID INSULATION (MIN.
2") ON CONT. VAPOR RETARDER ON 1/2"
EXT. GRADE PLY SHEATHING ON 2X10
WD FRAMING WITH R-33 BATT
INSULATION
ROOF TYPE 4 (ASPHALT) 1HR FIRE-RATED
ASPHALT SHINGLE ON ROOFING PAPER
ON 3/4" EXT. GRADE PLY SHEATHING ON
2X10 WD FRAMING FILLED WITH R-38
BATT INSULATION
ROOF TYPE 4 (ASPHALT) 1HR FIRE-RATED
ASPHALT SHINGLE ON ROOFING PAPER
ON 3/4" EXT. GRADE PLY SHEATHING ON
2X10 WD FRAMING FILLED WITH R-38
BATT INSULATION
ROOF OVER 1ST FLOOR
ROOF OVER 2ND FLOOR
2x10 AT 16" OC2x10 AT 16" OC2x10 AT 16" OC2x10 AT 16" OCROOF AT NEW DORMER
CODE REQUIRED 1HR FIRE-RATED FIRE-
TREATED AND FIRE-RESISTANT
EXTERIOR WALL FRAMING, MATERIALS,
WINDOW OPENINGS, & ROOF
OVERHANG
2' - 0"
DEMOLITION NOTES
1. REMOVE DOOR AND FRAME SYSTEM COMPLETELY, REPAIR
ROUGH OPENING TO RECIEVE NEW DOOR OPENING
TRIMWORK
2. EXISTING MILLWORK AND APPLIANCES TO BE REMOVED
COMPLETE.
3. REMOVE EXISTING HEATING SYSTEMS COMPLETE.
4. ELEMENTS TO REMAIN IN PLACE SHALL BE PROTECTED
FROM DAMAGE, DUST AND DEBRIS.
5. CONTRACTOR TO MAINTAIN WATER TIGHT INTEGRITY OF
BUILDING AT ALL TIMES.
6. ALL FLOOR AND WALL CONDITIONS WHICH ARE TO RECEIVE
NEW CONSTRUCTION ARE TO BE DEMOLISHED AS INDICATED
AND PROPERLY PREPPED TO RECEIVE NEW FINISHES, U.O.N.
7. ALL FLOOR, WALL, AND CEILING CONDITIONS THAT ARE
DISTURBED BY DEMOLITION ARE TO BE PATCHED, REPAIRED
AND/OR PAINTED WITH SIMILAR MATERIALS. REFER TO
PROPOSED PLANS FOR LOCATIONS.
8. ALL ELECTRICAL REMOVALS TO BE PERFORMED BY A
LICENSED ELECTRICIAN.RELABEL PANELS. FOLLOW N.E.C.
(NFPA 70). PROVIDE THIRD-PARTY INSPECTION.
9. PRIOR TO COMMENCING REMOVALS WORK, AND UNTIL SUCH
TIME THAT FINAL WORK IS IN PLACE, CONTRACTOR SHALL
ASCERTAIN REQUIREMENTS FOR, AND PROVIDE, BRACING,
SHORING AND OTHER TEMPORARY SYSTEMS OF SUPPORT
NEEDED TO PREVENT DAMAGE TO EXISTING CONSTRUCTION
WHICH IS SCHEDULED TO REMAIN.
10. SHUT OFF, CAP AND OTHERWISE PROTECT EXISTING
UTILITIES IN STRICT ACCORDANCE WITH THE REQUIREMENTS
OF THE PUBLIC AGENCIES OR UTILITIES HAVING
JURISDICTION AND AS DIRECTED ON THE MECHANICAL AND
ELECTRICAL DRAWINGS.
11. COMPLETELY REMOVE ITEMS SCHEDULED TO BE
DEMOLISHED AND REMOVED, LEAVING SURFACES CLEAN,
SOLID AND READY TO RECEIVE NEW MATERIALS SPECIFIED
ELSEWHERE.
12. DEMOLISHED MATERIALS SHALL BE COMPLETELY REMOVED
FROM THE JOB SITE AND DISPOSED OF PROPERLY UNLESS
OTHERWISE DIRECTED BY OWNER.
13. ALL EXISTING ITEMS SCHEDULED TO REMAIN SHALL BE
FULLY PROTECTED FROM ANY DELETERIOUS EFFECT
DURING ALL PHASES OF THE PROJECT. ANY DAMAGE TO
EXISTING ITEMS (WHETHER THEY ARE SHOWN ON THE
DRAWINGS OR NOT) SHALL BE CORRECTED TO THE
SATISFACTION OF THE OWNER AT THE EXPENSE OF THE
CONTRACTOR.
DEMOLITION LEGEND
EXISTING WALL TO BE REMOVED
EXISTING DOOR AND FRAME TO BE REMOVED
EXISTING WALL TO REMAIN
EXISTING DOOR TO REMAIN
14. ALL REMOVALS INDICATED MAY REQUIRE THE
COORDINATED REMOVAL OF EXISTING MECHANICAL,
ELECTRICAL, SECURITY SYSTEM, FIRE ALARM SYSTEM,
DATA AND TELEPHONE SYSTEM AND PLUMBING
EQUIPMENT AND LINES -REFER TO MECHANICAL AND
ELECTRICAL CONTRACTORS FOR INFORMATION
REGARDING EXISTING AND NEW H.V.A.C., PLUMBING,
ELECTRICAL ETC., RELATED WORK PRIOR TO
COMMENCING DEMOLITION.
15. COORDINATE ALL PARTIAL PARTITION REMOVAL
DIMENSIONS WITH FLOOR PLAN PRIOR TO DEMOLITION
TAKING PLACE.
16. REMOVE ALL ABANDONED PIPING, WIRING, EQUIPMENT,
LIGHTING, DUCTWORK, TUBING, SUPPORTS, FIXTURES,
ETC., BACK TO ITS ORIGINATION POINT, IN ITS ENTIRETY.
VISIT EACH ROOM, CRAWL SPACE, ROOF, AND BUILDING
EXTERIOR TO DETERMINE TOTAL SCOPE OF WORK.
17. DISCONNECT, REMOVE, RELOCATE AND PERMANENTLY
RECONNECT ANY AND ALL EXISTING MECHANICAL AND
ELECTRICAL WORK THAT IS REQUIRED TO REMAIN, BUT
INTERFERING WITH NEW CONSTRUCTION.
18. THE CONTRACTOR SHALL NOT LEAVE, ABANDONED,
PIPING, DUCTWORK, CONDUIT OR OUTLET BOXES IN
PLACE, EXCEPT THOSE ABANDONED ITEMS
PERMANENTLY BURIED AND CONCEALED IN EXISTING
WALLS AND FLOORS. THE CONTRACTOR SHALL REMOVE
ALL EXISTING EXPOSED AND ABANDONED PIPING,
DUCTWORK, OUTLET BOXES, CONDUITS, ETC., EVEN
THOSE ABANDONED ABOVE EXISTING CEILINGS, IN
EITHER RENOVATED AREAS, OR IN AREAS NOT BEING
RENOVATED. THOSE LEFT ABANDONED WITHIN EITHER
EXISTING WALLS OR FLOORS, SHALL BE CUT OFF AT THE
POINT WHERE THEY EXIT WALL OR FLOOR, CAPPED AND
COVERED FLUSH.
19. EXISTING EQUIPMENT CONNECTIONS AND WIRING
DEVICES, SCHEDULED FOR RELOCATION, SHALL BE
EXTENDED TO NEW LOCATION UTILIZING THE SAME
MATERIALS AND METHODS PREVIOUSLY USED.
(EXAMPLE: IF EXISTING WIRING DEVICE OUTLET WAS
PREVIOUSLY INSTALLED WITH GALVANIZED RIGID STEEL
CONDUIT, NEW RELOCATED OUTLET SHALL BE EXTENDED
WITH NEW GALVANIZED RIGID STEEL CONDUIT.)
FRAMING PLAN NOTES FRAMING PLAN LEGEND
1. ALL DIMENSIONS ARE FROM FACE OF FRAMING U.O.N.
2. CONC. CONTRACTOR TO BE RESPONSIBLE FOR ALL CONC. CUTTING & REMOVAL.
3. THE CONTRACTOR SHALL VERIFY EXISTING AND FIELD CONDITIONS. THE CONTRACTOR SHALL
NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR REQUIRED MODIFICATIONS PRIOR TO
COMMENCING INSTALLATION OF EQUIPMENT AND ASSOCIATED WORK.
4. PROVIDE DOUBLE STUDS AT JAMBS OF ALL DOORS, WINDOWS AND SIMILAR OPENINGS.
5. ALL CONNECTORS USED IN PRESSURE-TREATED WOOD FRAMING SHALL BE STAINLESS OR
GALVANIZED STEEL.
6. ALL HEADERS, FLOOR JOISTS & RAFTERS ARE TO BE SPRUCE-PINE-FIR #2 OR BETTER, STUDS -
STUD GRADE
7. ALL HEADERS ARE TO BE 3-2X10'S UNLESS OTHERWISE SPECIFIED.
8. JOISTS:
A. SHALL BE SUPPORTED LATERALLY (TO PREVENT ROTATION) AT THE ENDS BY FULL DEPTH SOLID
BLOCKING NOT LESS THAN 2" NOMINAL THICKNESS OR BY ATTACHMENT TO HEADER, BAND, RIM
JOIST, OR TO AN ADJOINING STUD.
B. IN SEISMIC DESIGN CATEGORIES D1 AND D2, LATERAL RESTRAINT MUST BE PROVIDED AT EACH
INTERMEDIATE SUPPORT R502.7.
9. NOTCHING REQUIREMENTS FOR EXTERIOR LOAD BEARING WALLS:
A. LOAD BEARING WALLS CUT MORE THAN 50% MUST BE SECURED BY A METAL TIE .054 THICK BY 1
1/2 INCHES WIDE WITH 8-16D NAILS ON EACH SIDE EXCEPT WHERE EXTERIOR WALLS ARE
COVERED BY SHEATHING.
B. HOLES BETWEEN 40% AND 60% OF STUD DEPTH REQUIRE DOUBLE STUDS.
C. NO HOLES ARE PERMITTED WITHIN 5/8 INCH OF THE EDGE OF ANY STUD.
D. NO HOLES ARE PERMITTED WITHIN ON THE SAME CROSS SECTION AS A NOTCH ON ANY STUD.
E. NO NOTCHES ARE PERMITTED TO BE MORE THAN 25% OF THE STUD DEPTH . R502.8., 602.6(1).(2)
R602.6.1
10. ALL HEADERS, GIRDERS SUPPORTING BEAMS AND OTHER STRUCTURAL COMPONENTS ARE
COVERED UNDER R301.1.3 ENGINEERED DESIGN. THESE DRAWINGS HAVE BEEN PREPARED UNDER
THE DIRECT SUPERVISION AND SEALED BY A NEW YORK STATE CERTIFIED PROFESSIONAL
STRUCTURAL ENGINEER IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE (ASCE-7)
11. ALL TOP PLATES AND SILL PLATES SHALL BE #3 SYP OR DFL (19% MC) OR BETTER.
12. HEADERS, FLUSH BEAMS, AND DROP BEAMS SHALL BE #2 DFL OR SYP (19%MC) OR BETTER, U.O.N.
13. ALL HEADERS AND BEAMS SHALL HAVE DOUBLE STUD PACK UNDER EACH END, U.O.N.
14. SIMPSON CS20 X 48" LONG STRAPS SPACED AT 48" O.C. SHALL BE USED ALONG THE EXTERIOR OF
THE BUILDING CENTERED ACROSS THE FLOOR CAVITY.
15. THE STABILITY OF THE FLOOR IS NOT ACHEIVED UNTIL THE DECKING HAS BEEN PROPERLY
INSTALLED AND FASTENED.
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME TO REMAIN
NEW WALL
NEW DOOR
TYPE ID
W4
W4T
W6
PARTITION ASSEMBLY
1/2" GYP BD ON 2X4 WD FRAMING ON 1/2"
GYP BD, TYPICAL U.O.N.
1/2" GYP BD ON TURNED 2X4 WD FURRING
1/2" GYP BD ON 2X6 WD FRAMING ON 1/2"
GYP BD
WALLS WITH THIS SYMBOL INDICATE 3"
SOUND-ABSORBING INSULATION IS ADDED
FOR ACOUSTICAL INSULATION
DESIGN LOADS:
FIRST FLOOR
SECOND & ATTIC FLOOR
ROOF
LOADS:
40 PSF LIVE / 10 PSF DEAD
40 PSF LIVE / 10 PSF DEAD
50 PSF GROUND SNOW
47 PSF FLAT ROOF SNOW
20 PSF DEAD
115 MPH WIND
EXPOSURE: B
ROOF PLAN NOTES
1. ALL DIMENSIONS ARE PROVIDED FOR GENERAL INFORMATION PURPOSES ONLY.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS DURING LAYOUT AND INFORM
ARCHITECT OF ANY DISCREPANCIES OR NECESSARY MODIFICATIONS PRIOR TO
PROCEEDING WITH CONSTRUCTION.
2. ± NOTATIONS ARE USED IN DIMENSION STRINGS TO ACCOUNT FOR VARIATIONS
BETWEEN DRAWINGS AND FIELD CONDITIONS.
3. PATCH, REPAIR AND OTHERWISE RECONSTRUCT ROOFING SYSTEMS WHERE NEW
WORK PENETRATES OR OTHERWISE AFFECTS EXISTING ROOFING SYSTEMS, AS
REQUIRED TO PROVIDE A WEATHERTIGHT INSTALLATION. PROVIDE NEW MATERIALS
TO MATCH EXISTING SIMILAR MATERIALS, COMPATIBLE WITH AND FULLY INTEGRATED
INTO EXISTING ROOFING SYSTEMS.
4. REPAIR AND RECONSTRUCTION WORK TO EXISTING ROOFING SYSTEMS SHALL BE
PROVIDED AS REQUIRED TO MAINTAIN OWNER'S EXISTING ROOFING WARRANTY
AND/OR WARRANTIES.
5. ALL FLASHINGS, COPINGS, SEAMS, AND TRANSITIONS SHALL BE DONE PER ROOFING
MANUFACTURER'S STANDARD DETAILS AND INSTALLATION INSTRUCTIONS.
6. FOLLOW ALL ROOFING SYSTEM MANUFACTURER'S STANDARD INSTALLATION
INSTRUCTION AND DETAILS.
7. INSTALL NON-CORROSIVE FLASHING AT WALL AND ROOF INTERSECTIONS, ROOF
SLOPE OR DIRECTION CHANGES AND AROUND ALL ROOF OPENINGS.
Scale
Project number
Date
devon telberg, aia
665 Saratoga Rd
Wilton, NY 12831
t (518) 212-7778
e devon@telbergstudio.com PROGRESS -NOT FOR CONSTRUCTI ON 8/12/2024 1:57:14 AMAs indicated
A104
Roof Removal, Framing and Proposed Plan
2404
The Bergman Residence 8/11/24
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation No. Description Date
1/4" = 1'-0"1 Roof Removal Plan
1/4" = 1'-0"2 Roof Framing Proposed Plan
Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
T/O Roof
34' -6"
Ex. Basement
-7' -6 1/2"
Grade
-4' -0"13' - 9 1/2"9' - 5"11' - 3 1/2"7' - 6 1/2"Ex. Attic
20' -8 1/2"
1
A3022
AT EXTG ROOF
NEW DORMER
ORIGINAL HISTORIC BLDG
EXISTING TO REMAIN NEW ADDITION
NEW RETAINING WALL AT +1' -0" ABOVE GRADE PLANE
PATCH EXTG WINDOW
OPENING WITH
SALVAGED BRICK TO
MATCH EXTERIOR
43 43
35
36 36 36
NEW WALL PENETRATION FOR NEW
FIREPLACE VENT
Addition T.O.S.
-8' -1"
RE-GRADE EXTG EARTH 1:2 SLOPE MAX. FROM
ORIGINAL BLDG TO END OF RETAINING WALL
S.M. FLASHING
UNDER SIDING, TYP.
1/2"
12"
ROOF TYPE 4 (ASPHALT) 1HR FIRE-RATED
ASPHALT SHINGLE ON ROOFING PAPER
ON 3/4" EXT. GRADE PLY SHEATHING ON
2X10 WD FRAMING FILLED WITH R-38
BATT INSULATION
EXTERIOR WALL -SIDING ON 2X8
HARDIPLANK SIDING ON WEATHER
BARRIER ON 3/4" EXT. GRADE PLY
SHEATHING ON 2X8 WD FRAMING ON
VAPOR BARRIER ON PTD. 1/2" GWB
(TYPICAL AT 1ST FL)
1/4"
12"
Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
T/O Roof
34' -6"
Ex. Basement
-7' -6 1/2"
Grade
-4' -0"
Ex. Attic
20' -8 1/2"
8' - 7"
10' - 4 1/2"
353535
D164
33
39 39 39 39 353535
35 35 35
D62
6 1/2"3' - 6 1/2"4' - 0"11' - 3 1/2"9' - 5"13' - 9 1/2"S.M. FLASHING UNDER SIDING, TYP.
SLOPE SLOPE
Addition T.O.S.
-8' -1"
EXTERIOR WALL -SIDING ON 2X8
HARDIPLANK SIDING ON WEATHER
BARRIER ON 3/4" EXT. GRADE PLY
SHEATHING ON 2X8 WD FRAMING ON
VAPOR BARRIER ON PTD. 1/2" GWB
(TYPICAL AT 1ST FL)
ROOF TYPE 4 (ASPHALT) 1HR FIRE-RATED
ASPHALT SHINGLE ON ROOFING PAPER
ON 3/4" EXT. GRADE PLY SHEATHING ON
2X10 WD FRAMING FILLED WITH R-38
BATT INSULATION
EXTERIOR WALL -SIDING ON 2X6
HARDIPLANK SIDING ON WEATHER
BARRIER ON 3/4" EXT. GRADE PLY
SHEATHING ON 2X6 WD FRAMING ON
VAPOR BARRIER ON PTD. 1/2" GWB
EXTERIOR WALL -BRICK ON 2X6
BRICK WITH WEEPS EVERY 16" O.C.
(SECURED TO FRAMING WITH GALV.
METAL TIES EVERY 16" O.C.), ON 1"
AIRSPACE, ON CONT. WEATHER
BARRIER , ON 1/2" EXT. GRADE GYPSUM
SHEATHING, ON 2X6 WD FRAMING AT 16"
O.C. WITH R-21 BATT INSULATION, ON
PTD. 1/2" GWB
NEW DOOR OPENING IN EXTG EXT.
WALL. NEW STL LINTEL TO SUPPORT
BRICK WALL ABOVE
ROOF TYPE 1 (TPO)
TPO MEMBRANE ADHERED TO 7/16" OSB
EXT. GRADE COVER BOARD ON
TAPERED R-10 RIGID INSULATION (MIN.
2") ON CONT. VAPOR RETARDER ON 1/2"
EXT. GRADE PLY SHEATHING ON 2X10
WD FRAMING WITH R-33 BATT
INSULATION
ROOF TYPE 3 (DECK)
1x4 TREX DECKING ON PRESSURE-TRD
WD SLEEPERS ON TPO MEMBRANE
FULLY ADHERED WITH HEAT-WELDED
SEAMS ON 5/8" THK COVER BOARD ON
R-10 (MIN. 2") RIGID INSULATION ON 3/4"
THK EXTERIOR GRADE PLY SHEATHING
ON WD FRAMING
REPAIR EXISTING LOUVERED
ATTIC VENTS TO REMAIN, PAINT
SAME COLOR AS TRIM
Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
T/O Roof
34' -6"
Ex. Basement
-7' -6 1/2"
Grade
-4' -0"
Ex. Attic
20' -8 1/2"
NEW DORMER AT EXISTING ROOF
EXISTING TO REMAIN
13' - 9 1/2"9' - 5"11' - 3 1/2"4' - 0"3' - 6 1/2"3"
12"
NEW RAILING ON EXTG
STAIR, 3' -6" HT
PATCH AND REPAIR EXTG STAIR
AND FRONT DOOR, STAIN AND
SEAL
SCRAPE, PATCH, REPAIR ALL
EXISTING WOOD TRIMWORK
AND DOOR AWNINGS. PAINT
ACCORDING TO OWNER'S
SELECTED COLOR, TYP.
Addition T.O.S.
-8' -1"
76
ADDRESS IDENTIFICATION
Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
T/O Roof
34' -6"
Ex. Basement
-7' -6 1/2"
Grade
-4' -0"
Ex. Attic
20' -8 1/2"
1
A3022
NEW ADDITION
ORIGINAL HISTORIC BLDG
EXISTING TO REMAIN
NEW WINDOW AT EXTG WALL
NEW WINDOW AT EXTG LOCATION
PATCH EXTG OPENING WITH SALVAGED
BRICK TO MATCH EXTERIOR
35
35
26
4213' - 9 1/2"9' - 5"11' - 3 1/2"4' - 0"3' - 6 1/2"2 1/8"
12"
SCRAPE, PATCH, REPAIR ALL EXISTING WOOD
TRIMWORK AND DOOR AWNINGS. PAINT ACCORDING
TO OWNER'S SELECTED COLOR, TYP.
REPAIR EXISTING WINDOW AND
RETROFIT FOR NEW MECHANICAL WORK
1/2"
12"
NEW WALL PENETRATION FOR STOVE HOOD EXHAUST
Scale
Project number
Date
devon telberg, aia
665 Saratoga Rd
Wilton, NY 12831
t (518) 212-7778
e devon@telbergstudio.com PROGRESS -NOT FOR CONSTRUCTI ON 8/12/2024 1:57:30 AM3/16" = 1'-0"
A200
Elevations
2404
The Bergman Residence 8/11/24
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
3/16" = 1'-0"1 West Elevation
3/16" = 1'-0"2 South Elevation
3/16" = 1'-0"3 North Elevation
3/16" = 1'-0"4 East Elevation
No. Description Date
Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
T/O Roof
34' -6"
Ex. Basement
-7' -6 1/2"
Grade
-4' -0"
Ex. Attic
20' -8 1/2"13' - 9 1/2"9' - 5"11' - 3 1/2"4' - 0"3' - 6 1/2"REMOVE ADDITION CONNECTIONS
DOWN TO HISTORIC BRICK. PATCH
AND REPAIR BRICK TO RECEIVE NEW
CONSTRUCTION
REMOVE STONE WALLS FOR NEW OPENING AT BASEMENT LEVEL
REMOVE EXTG FOOTING, REPAIR SLAB EDGE TO RECEIVE NEW CONSTRUCTION
+ 8' - 10" AFF
T/O EXTG
OPENING V.I.F.
REMOVE EXTG BRICK
WALL ON WD FRAMING
UP TO FLOOR JOIST
LEVEL ABOVE
REMOVE EXTG BRICK
WALL ON WD FRAMING
UP TO XXX
REMOVE ADDITION COMPLETELY, PATCH AND
REPAIR ORIGINAL BLDG'S WALL ASSEMBLY TO
RECEIVE NEW CONNECTIONS AND MATERIALS
EXISTING ADDITION
ORIGINAL
HISTORIC
BLDG
REMOVE
COMPLETELY
ORIGINAL PORCH
CONSTRUCTION
PATCH AND REPAIR EXTG BRICK, ADD NEW BRICK
WHERE NEEDED TO PROVIDE STRAIGHT OPENING.
RE-GROUT TO MATCH EXISTING FOR CLEAN, GOOD
REPAIR, TYP.
EXCAVATE EARTH AND PREPARE COMPACT SOIL TO RECEIVE NEW FOUNDATION
REMOVE COMPETELY
INTERIOR WALLS AND
FINISHES DOWN TO
FOUNDATION WALLS AT
BASEMENT LEVEL, TYP.
Addition T.O.S.
-8' -1"
Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
Ex. Basement
-7' -6 1/2"
Ex. Attic
20' -8 1/2"
1
A3022
1
A3022
+ 8' - 10" AFF
B/O SOFFIT CLG FIN.
T/O LANDING
Addition T.O.S.
-8' -1"
T/O FOUNDATION WALL
TENSION-CABLE (4"" MAX. SPACING) AND 1"" DIA. POST
RAILING
+ 5' - 1" ABV SS1' - 8 3/4"6' - 4 1/4"35 35
3535
PROVIDE NEW 1/2" GYP BD
PTD FINISH TO EXTG ATTIC
WD FRAMING, TYP.
SOFFIT VENTS, TYP.
+ 2' - 6 1/2" AFF
T/O SILL HT
R-15 CLOSED CELL INSULATION
AT INTERIOR SIDE OF
FOUNDATION WALL BETWEEN
TURNED 2X4 WD FRAMING, TYP.BELOW GRADE2' - 0" MIN.PROTECTIVE BOARD ON
R-10 RIGID INSULATION,
TYP.
ORIGINAL STONE
FOUNDATION WALL TO
REMAIN
W4T2X4 WD FRAMING ON SHIMS ON
EXTG STONE FOUNDATION WALL,
WALLS TO BE PLUMB, TYP.
CONTRACTOR TO V.I.F. TOP OF
WALL CONDITION, SECURE NEW
STRUCTURAL FRAMING TO EXISTING
PROVIDE NEW HDWD FLOOR
FINISH ON NEW FLOOR
STRUCTURAL ASSEMBLY, TYP.
REMOVE BRICKS AT FULL HEIGHT OF
1ST FLOOR NEW OPENINGS
NEW LINTEL TO SUPPORT BRICKS
TO REMAIN, SECURE TO NEW
HEADER FRAMING. SIZE TO BE
DELEGATED DESIGN BY MANF.
4" CONC. ON POLYETHYLENE VAPOR
BARRIER ON R-10 XPS RIGID
INSULATION ON 4" GRAVEL
4-PLY 1 3/4"X14" LVL, SEE FRAMING PLAN
+ 6' - 4" AFF
A301
6
1' - 0"3' - 6"1/4"
12"
3"
12"
ROOF TYPE 4 (ASPHALT) 1HR FIRE-RATED
ASPHALT SHINGLE ON ROOFING PAPER
ON 3/4" EXT. GRADE PLY SHEATHING ON
2X10 WD FRAMING FILLED WITH R-38
BATT INSULATION
EXTERIOR WALL -SIDING ON 2X8
HARDIPLANK SIDING ON WEATHER
BARRIER ON 3/4" EXT. GRADE PLY
SHEATHING ON 2X8 WD FRAMING ON
VAPOR BARRIER ON PTD. 1/2" GWB
(TYPICAL AT 1ST FL)
ROOF TYPE 3 (DECK)
1x4 TREX DECKING ON PRESSURE-TRD
WD SLEEPERS ON TPO MEMBRANE
FULLY ADHERED WITH HEAT-WELDED
SEAMS ON 5/8" THK COVER BOARD ON
R-10 (MIN. 2") RIGID INSULATION ON 3/4"
THK EXTERIOR GRADE PLY SHEATHING
ON WD FRAMING
A500
6
A500
7
A500
3
SIM
EXTERIOR WALL -SIDING ON 2X6
HARDIPLANK SIDING ON WEATHER
BARRIER ON 3/4" EXT. GRADE PLY
SHEATHING ON 2X6 WD FRAMING ON
VAPOR BARRIER ON PTD. 1/2" GWB
LEDGER, P.T. 2X10 THRU-BOLTED TO
RIM W/2 GALV. 1/2" BOLTS OR LAG
BOLTED WITH LEDGE LOCK, TYP.
LEDGER, P.T. 2X10 THRU-BOLTED TO
RIM W/2 GALV. 1/2" BOLTS OR LAG
BOLTED WITH LEDGE LOCK, TYP.
ALIGN FACE OF FINISH TO
EXPOSED BRICK WALL
BEYOND
HURRICANE TIE H2.5, TYP.3' - 6"3' - 6"Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
Ex. Basement
-7' -6 1/2"
Grade
-4' -0"
Ex. Attic
20' -8 1/2"
1
A301
1
A301
1
A3022
1
A3022
Addition T.O.S.
-8' -1"
TENSION-CABLE (4"" MAX. SPACING) AND 1"" DIA. POST
RAILING
CONC. RETAINING
WALL BEYOND9' - 5"11' - 3 1/2"4' - 0"3' - 6 1/2"6 1/2"PROVIDE OWNER-
SELECTED LT. FIXT., TYP.
1/2" PTD. EXT. GRADE
GRADE A PLY. SOFFIT
PANEL AT UNDERSIDE
WITH SOFFIT VENT, TYP.
NEW CORBEL TO
MATCH EXISTING, TYP.
2' - 0" OVERHANG
39
D164
35
35
D62
REFER TO INTERIOR
DWGS FOR
TRIMWORK, TYP.SOFFIT CEILING AT LOW
ROOF BEYOND
EXTG CLG HT TO REMAIN6' - 7 1/2"NEW CLG HT AT ADDITION7' - 2"GAME ROOM
24
DINING
12
BEDROOM 2
206
BATHROOM 2
207
GREAT ROOM
212
LIVING
11
W4T
1/2"
12"
6" X 6" TRENCH DRAIN EMBEDDED
INTO CONC. SLAB, CENTER LINE
ALIGNED WITH ROOF EDGE
OVERHANG ABOVE
1/4" / 12"
REPAIR AND INFILL EXTG CONC.
SLAB EDGE TO MAKE CLEAN 90-DEG
CORNER, ALIGN WITH EXTG SLAB
FILL WITH OPEN CELL INSULATION
A301
5
FINISH FLOOR, SEE
INTERIOR DWGS
A500
4
A500
3
A500
2
FLOOR TYPE 2
NEW FLOOR FINISH ON 1/2" PLY
SUBSTRATE ON 2x10 WD AT 16" O.C. ON
1/2" GWB
ROOF TYPE 1 (TPO)
TPO MEMBRANE ADHERED TO 7/16" OSB
EXT. GRADE COVER BOARD ON
TAPERED R-10 RIGID INSULATION (MIN.
2") ON CONT. VAPOR RETARDER ON 1/2"
EXT. GRADE PLY SHEATHING ON 2X10
WD FRAMING WITH R-33 BATT
INSULATION
ROOF TYPE 3 (DECK)
1x4 TREX DECKING ON PRESSURE-TRD
WD SLEEPERS ON TPO MEMBRANE
FULLY ADHERED WITH HEAT-WELDED
SEAMS ON 5/8" THK COVER BOARD ON
R-10 (MIN. 2") RIGID INSULATION ON 3/4"
THK EXTERIOR GRADE PLY SHEATHING
ON WD FRAMING
A500
1
FLOOR TYPE 2
NEW FLOOR FINISH ON 1/2" PLY
SUBSTRATE ON 2x10 WD AT 16" O.C. ON
1/2" GWB
FOUNDATION FLOOR TYPE 1
4" CONC. WITH W.W.F. ON
POLYEHTYLENE VAPOR BARRIER ON
R-10 POLYISOCYANURATE RIGID
INSULATION ON 4" STONE ON
COMPACTED FILL
EXTERIOR WALL -PTD BD ON 2X6
PTD 3/4" THK BOARD ON CONT.
WEATHER BARRIER ON 1/2" EXT GRADE
PLY SHEATHING ON 2X6 WD FRAMING
ON PTD 1/2" GWB
PATIO AT GRADE
STONE SET IN 4" CONC. SLAB ON 4"
GRAVEL. TOP OF NEW SLAB AT -0 -7" EL.
BELOW T.O.S. ADDITION LEVEL
EXTERIOR WALL -SIDING ON 2X6
HARDIPLANK SIDING ON WEATHER
BARRIER ON 3/4" EXT. GRADE PLY
SHEATHING ON 2X6 WD FRAMING ON
VAPOR BARRIER ON PTD. 1/2" GWB3' - 6"2X10 DBL HEADER
STL LINTEL FOR SUPPORTING
NEW BRICK OPENING
A500
5
A500
8
LEDGER, P.T. 2X10 THRU-
BOLTED TO RIM W/2 GALV. 1/2"
BOLTS OR LAG BOLTED WITH
LEDGE LOCK, TYP.5"Scale
Project number
Date
devon telberg, aia
665 Saratoga Rd
Wilton, NY 12831
t (518) 212-7778
e devon@telbergstudio.com PROGRESS -NOT FOR CONSTRUCTI ON 8/12/2024 1:57:31 AMAs indicated
A300
Building Sections
2404
The Bergman Residence 8/11/24
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
1/4" = 1'-0"3 Removal Building Section
1/2" = 1'-0"1 Overall Section at Asphalt Roof Typical
No. Description Date
1/2" = 1'-0"2 Overall Section at TPO Roof Typical
1
2
3
4
5
6
7
8
9
10
11
12
13
14 Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
Ex. Basement
-7' -6 1/2"
Grade
-4' -0"
3
A300
3
A300
1
A300
1
A300
2
A300
2
A300
Addition T.O.S.
-8' -1"
OPEN TO BEYOND
OPEN TO BEYOND
OPEN TO
BEYOND
OPEN TO
BEYOND
UNOCCUPIED
SPACE UNDER
STAIR
FINISH FLOOR, SEE
INTERIOR DWGS, TYP.
TRIMWORK, SEE
INTERIOR DWGS, TYP.(11) RISERS AT 7" EA6' - 4 1/4"(4) RISERS AT 7" EA1' - 8 3/4"2' - 3 1/2"1' - 0"A301
2
A301
3
A301
4
A301
87' - 2" CH8' - 10"10' - 4 1/2"EXTERIOR WALL -SIDING ON 2X8
HARDIPLANK SIDING ON WEATHER
BARRIER ON 3/4" EXT. GRADE PLY
SHEATHING ON 2X8 WD FRAMING ON
VAPOR BARRIER ON PTD. 1/2" GWB
(TYPICAL AT 1ST FL)
ROOF TYPE 4 (ASPHALT) 1HR FIRE-RATED
ASPHALT SHINGLE ON ROOFING PAPER
ON 3/4" EXT. GRADE PLY SHEATHING ON
2X10 WD FRAMING FILLED WITH R-38
BATT INSULATION
ROOF TYPE 1 (TPO)
TPO MEMBRANE ADHERED TO 7/16" OSB
EXT. GRADE COVER BOARD ON
TAPERED R-10 RIGID INSULATION (MIN.
2") ON CONT. VAPOR RETARDER ON 1/2"
EXT. GRADE PLY SHEATHING ON 2X10
WD FRAMING WITH R-33 BATT
INSULATION
EXTERIOR WALL -BRICK ON 2X6
BRICK WITH WEEPS EVERY 16" O.C.
(SECURED TO FRAMING WITH GALV.
METAL TIES EVERY 16" O.C.), ON 1"
AIRSPACE, ON CONT. WEATHER
BARRIER , ON 1/2" EXT. GRADE GYPSUM
SHEATHING, ON 2X6 WD FRAMING AT 16"
O.C. WITH R-21 BATT INSULATION, ON
PTD. 1/2" GWB
FOUNDATION FLOOR TYPE 1
4" CONC. WITH W.W.F. ON
POLYEHTYLENE VAPOR BARRIER ON
R-10 POLYISOCYANURATE RIGID
INSULATION ON 4" STONE ON
COMPACTED FILL
FLOOR TYPE 2
NEW FLOOR FINISH ON 1/2" PLY
SUBSTRATE ON 2x10 WD AT 16" O.C. ON
1/2" GWB
35
LINE OF CROSS WD BLOCKING BEYOND
2X10 WD BLOCKING, SECURE STRUC
FRAMING AT BOTH ROOFS
1' - 0" MIN.3".
BENT SHEET METAL FLASHING WITH
1" DRIP EGDE. COLOR TO MATCH
EXTERIOR TRIM
PTD. 3/4" THK. HARDBOARD TRIM
PANEL, SAME COLOR AS TRIM
SEALANT (COLOR: BLACK IF TRIM
COLOR IS DARK)
METAL COUNTERFLASHING
SELF-ADHERED FLASHING
EXTEND SELF-ADHERED
FLASHING AT BOTTOM ROOF
MIN. 1' -6" FROM UPTURNFILL CAVITY WITH CLOSED CELL SPRAY
INSULATION, MIN. 6" AT EACH SIDE
TPO ROOF
ASPHALT
ROOF
BOTTOM OF CLG SOFFIT
Addition T.O.S.
-8' -1"
9"
2' - 1 1/4"
-9' - 1"
T/O FOOTING
POLYETHYLENE VAPOR
BARRIER, TYP.
R-10 XPS RIGID
INSULATION
4" CONC SLAB
SELF-ADHERED MEMBRANE ACROSS
JOINTS, UNDER SILL, AND EXTEND
EXTERIOR SIDE UNDER DRAINAGE MAT
4" GRAVEL
6" PERF. PVC DRAINAGE PIPE, TYP.
6" X 6" TRENCH DRAIN EMBEDDED
INTO CONC. SLAB, CENTER LINE
ALIGNED WITH ROOF EDGE
OVERHANG ABOVE
BLUESTONE ON 4"
CONC. ON 4" GRAVEL
DRAINAGE MAT
EXTEND R-10 XPS RIGID
INSULATION TO TRENCH DRAIN
FINISH FLOOR, SEE INTERIOR DWGS
1"Addition T.O.S.
-8' -1"
9"
-9' - 1"
T/O FOOTING
POLYETHYLENE VAPOR BARRIER, TYP.
R-10 XPS RIGID INSULATION
4" CONC SLAB
SELF-ADHERED MEMBRANE ACROSS
JOINTS, UNDER SILL, AND EXTEND
EXTERIOR SIDE UNDER DRAINAGE MAT
4" GRAVEL
6" PERF. PVC DRAINAGE PIPE, TYP.
6" X 6" TRENCH DRAIN EMBEDDED
INTO CONC. SLAB, CENTER LINE
ALIGNED WITH ROOF EDGE
OVERHANG ABOVE
BLUESTONE ON 4"
CONC. ON 4" GRAVEL
DRAINAGE MAT
EXTEND R-10 XPS RIGID
INSULATION TO TRENCH DRAIN
FINISH FLOOR, SEE INTERIOR DWGS
Addition T.O.S.
-8' -1"
1/2" GWB ON 2X4 TURNED WD FRAMING
WITH CLOSED CELL SPRAY INSULATION
BETWEEN STUDS SECURED TO
FOUNDATION WALL, TYP.TYP WALL
8"
TYP. FOOTING
1' - 4"
FOUNDATION DAMPPROOFING
GRAVEL
6" DIA. PERFORATED PVC
DRAINPIPE, TYP
4" CONC STRUC. SLAB ON
POLYETHYLENE VAPOR BARRIER ON
CONTINUOUS RIGID INSULATION
(R-10 MIN.) ON 4" GRAVEL, TYP
1" COMPRESSIBLE FILL AT
FLOOR EDGE, TYP
Scale
Project number
Date
devon telberg, aia
665 Saratoga Rd
Wilton, NY 12831
t (518) 212-7778
e devon@telbergstudio.com PROGRESS -NOT FOR CONSTRUCTI ON 8/12/2024 1:57:33 AMAs indicated
A301
Building Section and Details
2404
The Bergman Residence 8/11/24
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation No. Description Date
1/2" = 1'-0"1 Building Cross Section at Stair
1" = 1'-0"3 Section Detail at Roof Transition
1" = 1'-0"5 Section Detail at Foundation & Door Sill
1" = 1'-0"7 Section Detail at Typical Brick Wall Type
1" = 1'-0"8 xx
Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
T/O Roof
34' -6"
Ex. Attic
20' -8 1/2"
2
A303
3"
12"9' - 5"11' - 3 1/2"4' - 3 1/4"24' - 11 1/2"
B/O ROOF EAVE
STRUC COLUMN BEYOND, WITH WD
BLOCKING AND PTD. TRIMWORK. REFER
TO INTERIOR DWGS FOR FINISHES
EXISTING NON-CONFORMING
STAIR TREADS, RISERS AND
STRINGERS TO REMAIN
NEW HANDRAIL ON EXTG STAIR3' - 0"NEW DORMER AT STAIR
PTD. TRIMWORK AT FLOOR EDGE
PTD. GYP BD, TYP
PTD. GYP BD. ON WOOD BLOCKING
SECURED TO UNDERSIDE OF LANDING
AND STAIR STRINGERS
PROVIDE NEW SIDING AND PTD.
TRIMWORK TO ENCLOSE EXISTING ROOF
AT BOTH SIDES OF NEW DORMERSECURE EXTG EXTERIOR WALL WD
FRAMING AND BLOCKING WITH NEW
FRAMING FOR DORMER6"43
CLOSET
10A
LIVING
11
HALL
200
PRIMARY BEDROOM
201
GREAT ROOM
212
PTD. GYP. BD. OVER
EXISTING STAIR STRINGER
PTD. WD FINISH PLY. (SMOOTH) AT
STRINGER INTERIOR TO CLOSE
SPACE GAP BETWEEN STAIR AND
FLOOR ASSEMBLY ABOVE AT LESS
THAN 2'-0" HT.
NEW PTD. GYP BD. CLG ON
EXTG WD FRAMING, TYP.
PTD. GYP BD AT SLOPED UNDERSIDE
OF STAIR INSIDE CLOSET RM.
30
INFILL AT OPENING WITH SIMILAR,
CONTINUOUS MATERIALS TO ADJACENT
EXTG CONSTRUCTION OF BRICK ON WD
FRAMING WITH BATT INSULATION.
PROVIDE WATERTIGHT SEALS AND
SELF-ADHERING FLASHING TO PATCH
ADJ.
NEW 1 3/4" X 9 1/4" LVL BEAM
FOR STRUC SUPPORT AT
TOP OF STAIR
NEW R-38 FACED BATT INSULATION
BETWEEN EXISTING RAFTERS
VENTED FLAT SOFFIT, TYP.
2X12 HDWD STAIR STRINGER (CLOSED AT
WALL SIDE)
ROOF TYPE 4 (ASPHALT) 1HR FIRE-RATED
ASPHALT SHINGLE ON ROOFING PAPER
ON 3/4" EXT. GRADE PLY SHEATHING ON
2X10 WD FRAMING FILLED WITH R-38
BATT INSULATION
9' - 0" CH1 1/2"7' - 0"4 RISERS AT 7 1/4" EA2' - 3 1/4"12 RISERS AT 7 1/4" EA7' - 2"EXTERIOR WALL -SIDING ON 2X8
HARDIPLANK SIDING ON WEATHER
BARRIER ON 3/4" EXT. GRADE PLY
SHEATHING ON 2X8 WD FRAMING ON
VAPOR BARRIER ON PTD. 1/2" GWB
(TYPICAL AT 1ST FL)
Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
Ex. Attic
20' -8 1/2"
1
A303
6' - 8" CLR HTHALL
200
ENTRY
10
CLOSET
10A
GREAT ROOM
212
UNOCCUPIED SPACE
UNDER STAIR
NEW PTD. GWB FINISH
AT EXTG FLOOR EDGE,
2X4 WD FRAMING &
BLOCKING, TYP.4 RISERS AT 7 1/4" EA2' - 4 3/4"12 RISERS AT 7 1/4" EA.7' - 2"17 RISERS AT 8" EAEXISTING NON-CONFORMING STAIR11' - 3 1/2"+ 7' - 2" AFF
TOP OF LANDING
EXISTING LOAD-BEARING
WALL TO REMAIN
INFILL WALL AT REMOVED WINDOW
LOCATION TO MATCH ADJACENT
MATERIALS AND FINISHES
NEW PTD. GWB, TYP.
1 3/4" X 9 1/4" LVL, SEE
FRAMING PLAN
2X12 HDWD STAIR STRINGER
(CLOSED) AT WALL SIDE
2X6 HDWD LANDING
REPLACE TREADS AND
WOODWORK AT WALL REMOVAL,
FINISH SMOOTH AND CLEAN, TYP.
EXISTING ROOF ASSEMBLY AND
RAFTERS TO REMAIN
PROVIDE ADDITIONAL JOIST
STRUC SUPPORT AND SECURE
TO EXTG ROOF JOISTS FOR
STRUC SUPPORT NEW DORMER
WALLS AND ROOF
HEAD HT2' - 10 1/2"1 1/2"1 1/2"9' - 5"FLOOR TYPE 3 (ATTIC)
NEW FLOOR FINISH ON 3/4" PLY
SUBSTRATE ON SPF 2x10 AT 16" O.C.
(TOP TO BE FLUSH WITH EX. 2X6 JOISTS)
ON 1/2" GWB
6' - 8"4"HEAD CLR OBSTRUCTION MAX.
VARIANCE REQUESTED IN ORDER TO PROVIDE
BOTTOM LANDING DEPTH AT 2ND FL LANDING
AND MID-LANDING STRUCTURAL SUPPORT THAT
AVOIDS EXISTING EXTERIOR WINDOW LOCATION
43 43
Scale
Project number
Date
devon telberg, aia
665 Saratoga Rd
Wilton, NY 12831
t (518) 212-7778
e devon@telbergstudio.com PROGRESS -NOT FOR CONSTRUCTI ON 8/12/2024 1:57:33 AM1/2" = 1'-0"
A303
Section at New Dormer and Stair
2404
The Bergman Residence 8/11/24
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
1/2" = 1'-0"1 Section at Attic Stair - North-South
1/2" = 1'-0"2 Section at Attic Stair - East-West
PROGRESS -NOT FOR CONSTRUCTI ON No. Description Date
Existing
Proposed
All original decorative elements to remain
All original decorative elements to remain
House directly across the street
Neighboring Houses
Proposed Siding
Siding & Trim color
Siding corners on new
addition to be weaved
Proposed Roofing
Proposed Windows
Proposed new window style Proposed new window color
Proposed New Entry Door
Proposed New Entry Door Stain
Emtek
Proposed New Entry Knob
Proposed New Entry Pendant Rear exterior sconces
New Entry Pathway
Rear Patio
New Front Steps
Rooftop Railings
New House Numbers New Mailbox
Rear Addition Rafter Tails
DESCRIPTION
COVER PAGE
DRAWN BY
KF
ISSUE
04|01|24
PROJECT
76 WALTON
CLIENT
BILL BERGMANSTUDIO K.
76 WALTON ST.
SARATOGA SPRINGS NY, 12866
aDRAWN BYKFPROJECT76 WALTON ST01STUDIO K.FRONT ELEVATION
1/8” = 1’-0”
EXISTING FRIEZE
TO BE RESTORED
EXISTING SURROUND
SIMPLIFIED
NEW BRICK LANDSCAPE WALL
NEW BRICK LANDSCAPE WALL
NEW BRICK LANDSCAPE WALL
NEW WINDOW
& CASING
2'-0"4'-0"REAR ELEVATION
1/8” = 1’-0”
GATE TO REAR YARD10'-0"9'-0"10"10"7'-0"10"10'-0"10"9'-0"10"6"1'-0"1'-0"11'-0"9'-0"10"
aDRAWN BYKFPROJECT76 WALTON ST02STUDIO K.REAR ELEVATION
1/8” = 1’-0”
REAR ELEVATION
1/8” = 1’-0”
REAR ELEVATION
1/8” = 1’-0”10'-0"10"9'-0"10"10"1'-6"
3'-9"
8"3'-6"3'-0"1'-8"3'-9"
1'-0"
6"1'-0"6"1'-0"1'-0"10"3'-8"
4"
aDRAWN BYKFPROJECT76 WALTON ST03STUDIO K.FRONT ELEVATION
1/8” = 1’-0”10'-0"9'-0"10"10"10"23/33 FIXED
31/65 DH..
31/77 DH....
21/35 FIX.
REAR ELEVATION
1/8” = 1’-0”7'-0"10"10'-0"10"9'-0"10"16’ X 8’ DOUBLE SLIDER
44/106 FIX...
31/59 DH..
35/79 L IN SWING
35” SIDELITES 31/31 FIX ROUND
31/59 DH..
31/59 DH31/59 DH31/59 DH
64/96 FRENCH ENTRY 1'-4"2'-8"4'-5 1/2"2'-8"1'-4"1'-0"
6'-4"23'-6 1/2"4'-0"
1'-6"
3'-0"
1'-6"4'-0"5'-11"
aDRAWN BYKFPROJECT76 WALTON ST04STUDIO K.REAR ELEVATION
1/8” = 1’-0”10'-0"10"9'-0"10"10"2'-0"3'-0"31/59 DH
31/59 DH.
31/59 DH
25/47 R CSMT
31/17 AWN
31/65 DG
31/77 DH2'-8"
aDRAWN BYKFPROJECT76 WALTON ST05STUDIO K.REAR ELEVATION
1/8” = 1’-0”
31/65 DH
31/77 DH
31/31 FIXED ROUND 31/65 DH..
31/65 DH71/35 FIX
25/35 R CSMT
31/59 DH1'-8"4'-6"10'-5"5'-9"
16” RADIUS
3'-8"3'-1"5'-5"5'-0"
aDRAWN BYKFPROJECT76 WALTON ST06STUDIO K.MAIN LEVEL
1/8” = 1’-0”
SECOND LEVEL
1/8” = 1’-0”
LOUNGE PCKT
OFFICE
PWDR
KITCHEN
FRIDGE.FREEZ.
PANTRY
MECH.
DN
FP TBD
PRIMARY
BEDROOM
PRIMARY
BATH
WIC
WIC
JUNIOR
SUITE
GUEST
BEDROOM
LAUNDRY
LIVING
ROOM
DINING
OPEN TO
BELOW
aDRAWN BYKFPROJECT76 WALTON ST07STUDIO K.LOWER LEVEL
1/8” = 1’-0”
THIRD LEVEL
1/8” = 1’-0”
GYM
THEATER
BAR
MECH.
WIC
BENCH
GAME
ROOM
PLAY
ROOM
OFFICE
OPEN TO
BELOW
aDRAWN BYKFPROJECT76 WALTON ST08STUDIO K.MAIN LEVEL
1/8” = 1’-0”
SECOND LEVEL
1/8” = 1’-0”
11'-8"7'-8 1/2"8'-8"1'-5"4'-0"5'-4"3'
-
1
1
"
5'-8"4'-3"3'-2"5'-6"
2'-8"5'-2 1/2"5'-6"4'-0"4'-4 1/2"3'-0"11'-11"
2'-0"3'-0"9'-2"7'-11"
3'-3 1/2"7'-1"3'-3 1/2"6'-2"14'-5 1/2"3'-11"6'-8"6'-8 1/2"8'-1/2"8"2'-0"17'-10"
15'-3 1/2"1'-9"13'-7 1/2"11'-5 1/2"13'-7 1/2"16'-1 1/2"12'-1 1/2"9'-7 1/2"4'-0"1'-9"5'-10 1/2"11'-2 1/2"7'-5 1/2"9'-0"7 1/2"8"8"6"20'-0"12'-7 1/2"15'-6"5'-3"8"4"4"4"4'-2 1/2"6'-0"12'-1 1/2"
4'-0"8'-6 1/2"4'-6 1/2"3'-6 1/2"10'-6"26'-7"4'-0"22'-6"4'-0"3'-6"6'-0"15'-5 1/2"16'-3"3'-6"3'-9"
13'-7 1/2"15'-6"2'-9"7 1/2"4'-0"3'-1"3'-1 1/2"5'-3 1/2"5'-0"3'-0"5'-5"7'-1 1/2"5'-5"6'-3"10'-6 1/2"8'-0"5'-2 1/2"
5'-2"1'-5 1/2"5'-6"3'-6"2'-6 1/2"6'-4"4'-9 1/2"11'-1 1/2"11'-6 1/2"3'-9"5'-0"5'-5 1/2"10'-6"5'-0"3'-2"5'-8"4'-6"2'-10"
3'-4"3'-0"5'-9"6'-1"4'-3 1/2"2'-0"
2'-1/2"
2'-6"4'-9 1/2"7'-6"10'-9 1/2"5'-0"2'-9 1/2"4'-6"10'-9 1/2"12'-1"
7 1/2"8"8"7 1/2"18'-6 1/2"3'-11"6'-8"6'-8 1/2"
aDRAWN BYKFPROJECT76 WALTON ST09STUDIO K.LOWER LEVEL
1/8” = 1’-0”
THIRD LEVEL
1/8” = 1’-0”
18'-6 1/2"4'-6 1/2"4'-0"6'-0"
2'-4"5'-11 1/2"9'-10"
8'-6"
6'-10"15'-0"4'-10"8'-6 1/2"13'-10 1/2"12'-3"11'-1/2"16'-11 1/2"13'-3 1/2"6'-10"5'-2"3'-0"8'-7 1/2"4'-10 1/2"13'-9 1/2"4'-6"4'-3"1'-6"12'-10"2'-5 1/2"
12'-3"18'-8 1/2"7'-7"2'-3 1/2"4'-8"2'-10"1'-8"12'-10"9'-0"4'-1 1/2"11'-0"12'-6"3'-4"4'-7"8'-10"9'-0"11'-3"5'-10 1/2"14'-8"4'-8 1/2"7'-10 1/2"26'-2 1/2"6'-8 1/2"10'-10 1/2"3'-5"6'-11"
aDRAWN BYKFPROJECT76 WALTON ST10STUDIO K.10’-0”9’-8”10"7'-6"7'-8"9'-0"7'-0"8'-8"10’-0”6"STAIR SECTION 1
1/8” = 1’-0”
STAIR SECTION 2
1/8” = 1’-0”