HomeMy WebLinkAbout20230947 73 Henry Revisions to meet approval conditions SCALE:AS NOTED
TOTAL SHEETS
1 1
DRAWING NO.
SHEET NO.
S1
DRAWING TITLE
ROOF PLAN
ELEVATION
&
DETAILS
PROJECT NO. 2021-40-005
DATE
06.10.24
REVISION:NO.
APPROVED:
DRAWN BY:
DATE:
DWM
RAB
ON
L
Y
C
O
P
I
E
S
F
R
O
M
T
H
E
O
R
I
G
I
N
A
L
O
F
T
H
I
S
P
L
A
N
S
E
A
L
E
D
W
I
T
H
A
N
O
R
I
G
I
N
A
L
O
F
T
H
E
P
R
O
F
E
S
S
I
O
N
A
L
E
N
G
I
N
E
E
R
S
I
N
K
E
D
S
T
A
M
P
S
H
A
L
L
B
E
C
O
N
S
I
D
E
R
E
D
T
O
B
E
T
R
U
E
C
O
P
I
E
S
.
UN
A
U
T
H
O
R
I
Z
E
D
A
L
T
E
R
A
T
I
O
N
S
T
O
T
H
I
S
P
L
A
N
I
S
A
V
I
O
L
A
T
I
O
N
O
F
S
E
C
T
I
O
N
7
2
0
9
,
S
U
B
.
2
O
F
T
H
E
N
E
W
Y
O
R
K
S
T
A
T
E
E
D
U
C
A
T
I
O
N
L
A
W
.
C
O
P
Y
P
R
O
T
E
C
T
E
D
.
RO
N
A
L
D
A
.
B
O
V
A
P
.
E
.
LI
C
E
N
S
E
#
6
9
6
9
7
PR
O
P
O
S
E
D
R
O
O
F
G
U
T
T
E
R
R
E
T
R
O
F
I
T
47
C
A
R
O
L
I
N
E
S
T
R
E
E
T
SA
R
A
T
O
G
A
S
P
R
I
N
G
S
,
N
Y
BO
V
A
E
NG
I
N
E
E
R
I
N
G
P
L
L
C
FO
R
E
N
S
I
C
I
N
V
E
S
T
I
G
A
T
I
O
N
&
E
N
G
I
N
E
E
R
I
N
G
D
E
S
I
G
N
15
G
L
E
N
R
I
D
G
E
R
O
A
D
,
G
L
E
N
V
I
L
L
E
,
N
Y
1
2
3
0
2
PH
O
N
E
(
5
1
8
)
3
8
4
-
1
0
2
8
F
A
X
(
5
1
8
)
3
8
4
-
1
0
2
9
PLAN NORTH
E
S
W
(ROOF LEVEL PLAN)1
S1
BUILDING REFERENCE PLAN
SCALE: 1/4" = 1'-0"
± 74'-8"
RTU
RTU
RTU
SKYLIGHT
SKYLIGHT
SKYLIGHT
± 21'-4"
FAN
± 2'-4"± 72'-4"
±
5
'
-
0
"
S
E
T
B
A
C
K
FI
E
L
D
V
E
R
I
F
Y
ROOF REFERENCE ELEVATIONS
DOWN SLOPE
EXISTING ROOF
DOWN
DOWN
DO
W
N
DOW
N
NEW TAPERED INSULATION BOARD AREA
± 24'-6"
97.1
97.35
96.35
96.85
96.6
NEW HALF ROUND COPPER ROOF
GUTTER WITH 6" DIA. COPPER
DOWNSPOUT TO EXISTING STUB
THROUGH SIDEWALK.
SEE EAST ELEVATION 2/S1 &
PARTIAL ELEVATION 3/S1.
(HENRY STREET)2
S1
EAST ELEVATION
SCALE: 1/4" = 1'-0"
3
S1
PARTIAL ELEVATION
SCALE: 3/4" = 1'-0"
±
3
3
'
-
6
"
96.0
CONNECT NEW 6" DIAMETER DOWNSPOUT
WITH ELBOW AS REQUIRED TO EXISTING STUB
THROUGH SIDEWALK TO STORM DRAIN.
100.0
100.0
ROOF REFERENCE
ELEVATIONS
NEW 6" DIA. COPPER DOWNSPOUT TO
EXISTING STUB THROUGH SIDEWALK.
SEE EAST ELEVATION 2/S1.
3 S1
ISSUED FOR DESIGN REVIEW COMMISSION
(Architectural/Historical Review)
NOT FOR CONSTRUCTION
NEW HALF ROUND COPPER ROOF GUTTER
NEW CONDUCTOR HEAD WITH STRAINER
NEW CONDUCTOR HEAD WITH STRAINER
NEW 6" DIAMETER COPPER DOWNSPOUT
NEW HALF ROUND COPPER ROOF GUTTER
RAISED PERIMETER EDGE WITH METAL FLASHING
(FASCIA CAP) PER NRCA ROOFING MANUAL:
MEMBRANE ROOF SYSTEMS DETAIL EPDMA-2A
GUTTER WITH PERIMETER EDGE METAL PER
NRCA ROOFING MANUAL: MEMBRANE ROOF
SYSTEMS DETAIL EPDMA-29
TYPICAL WALL BRACKET
TYPICAL WALL BRACKERT