Loading...
HomeMy WebLinkAbout20230947 73 Henry Revisions to meet approval conditions SCALE:AS NOTED TOTAL SHEETS 1 1 DRAWING NO. SHEET NO. S1 DRAWING TITLE ROOF PLAN ELEVATION & DETAILS PROJECT NO. 2021-40-005 DATE 06.10.24 REVISION:NO. APPROVED: DRAWN BY: DATE: DWM RAB ON L Y C O P I E S F R O M T H E O R I G I N A L O F T H I S P L A N S E A L E D W I T H A N O R I G I N A L O F T H E P R O F E S S I O N A L E N G I N E E R S I N K E D S T A M P S H A L L B E C O N S I D E R E D T O B E T R U E C O P I E S . UN A U T H O R I Z E D A L T E R A T I O N S T O T H I S P L A N I S A V I O L A T I O N O F S E C T I O N 7 2 0 9 , S U B . 2 O F T H E N E W Y O R K S T A T E E D U C A T I O N L A W . C O P Y P R O T E C T E D . RO N A L D A . B O V A P . E . LI C E N S E # 6 9 6 9 7 PR O P O S E D R O O F G U T T E R R E T R O F I T 47 C A R O L I N E S T R E E T SA R A T O G A S P R I N G S , N Y BO V A E NG I N E E R I N G P L L C FO R E N S I C I N V E S T I G A T I O N & E N G I N E E R I N G D E S I G N 15 G L E N R I D G E R O A D , G L E N V I L L E , N Y 1 2 3 0 2 PH O N E ( 5 1 8 ) 3 8 4 - 1 0 2 8 F A X ( 5 1 8 ) 3 8 4 - 1 0 2 9 PLAN NORTH E S W (ROOF LEVEL PLAN)1 S1 BUILDING REFERENCE PLAN SCALE: 1/4" = 1'-0" ± 74'-8" RTU RTU RTU SKYLIGHT SKYLIGHT SKYLIGHT ± 21'-4" FAN ± 2'-4"± 72'-4" ± 5 ' - 0 " S E T B A C K FI E L D V E R I F Y ROOF REFERENCE ELEVATIONS DOWN SLOPE EXISTING ROOF DOWN DOWN DO W N DOW N NEW TAPERED INSULATION BOARD AREA ± 24'-6" 97.1 97.35 96.35 96.85 96.6 NEW HALF ROUND COPPER ROOF GUTTER WITH 6" DIA. COPPER DOWNSPOUT TO EXISTING STUB THROUGH SIDEWALK. SEE EAST ELEVATION 2/S1 & PARTIAL ELEVATION 3/S1. (HENRY STREET)2 S1 EAST ELEVATION SCALE: 1/4" = 1'-0" 3 S1 PARTIAL ELEVATION SCALE: 3/4" = 1'-0" ± 3 3 ' - 6 " 96.0 CONNECT NEW 6" DIAMETER DOWNSPOUT WITH ELBOW AS REQUIRED TO EXISTING STUB THROUGH SIDEWALK TO STORM DRAIN. 100.0 100.0 ROOF REFERENCE ELEVATIONS NEW 6" DIA. COPPER DOWNSPOUT TO EXISTING STUB THROUGH SIDEWALK. SEE EAST ELEVATION 2/S1. 3 S1 ISSUED FOR DESIGN REVIEW COMMISSION (Architectural/Historical Review) NOT FOR CONSTRUCTION NEW HALF ROUND COPPER ROOF GUTTER NEW CONDUCTOR HEAD WITH STRAINER NEW CONDUCTOR HEAD WITH STRAINER NEW 6" DIAMETER COPPER DOWNSPOUT NEW HALF ROUND COPPER ROOF GUTTER RAISED PERIMETER EDGE WITH METAL FLASHING (FASCIA CAP) PER NRCA ROOFING MANUAL: MEMBRANE ROOF SYSTEMS DETAIL EPDMA-2A GUTTER WITH PERIMETER EDGE METAL PER NRCA ROOFING MANUAL: MEMBRANE ROOF SYSTEMS DETAIL EPDMA-29 TYPICAL WALL BRACKET TYPICAL WALL BRACKERT