Loading...
HomeMy WebLinkAbout20240563 3376 S Broadway Treehouse Site Plan Modification PlansTDRAWING SHEET INDEXREVISIONSREVDATECOMMENTDRAWN BYCHECKED BY12345678REVISION 8 -01/19/2024CLIENT COMMENTSSGSW02/02/2024CITY COMMENTSSGVR03/04/2024CITY COMMENTSSGSW03/20/2024CITY COMMENTSSGVR04/15/2024CITY AND TDECOMMENTSAKDSRW05/03/2024PRELIMINARY ISSUEFOR CONSTRUCTIONAKDSRW06/07/2024DOT AND SCSDCOMMENTSAKDSRW06/14/2024ADDENDUM 1AKDSRW06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORP:\2023\NYB230191.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\NYB230191.00-SPPD-0A----->LAYOUT: C-101 COVRAD THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191SAG/AKDSRW11/30/2023NYB230191.00-SPPD-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK 2 - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comUSGS MAPSCALE: 1" = 200'SITE MAPSCALE: 1" = 1,000'SOURCE: SARATOGA SPRINGS QUADRANGLEAPPROVAL BLOCKAPPROVED UNDER THE AUTHORITY OF A RESOLUTIONADOPTED ________ BY THE PLANNING BOARD OF THE CITY OFSARATOGA SPRINGS.DATECHAIRPERSON:DATE SIGNED:PREPARED BYWESC-101COVERSHEETWESSOUTH B R O A D W A Y GC-RGATEWAY COMMERCIAL - RURAL"SARATOGA HONDA"BOUNDARY & TOPOGRAPHIC SURVEY:AUSFELD & WALDRUFF LAND SURVEYORS, LLP323 CLINTON STREET, SCHENECTADY, NYDATE: OCTOBER 6, 2023GEOTECHNICAL INVESTIGATION REPORT:WHITESTONE500 CANAL VIEW BOULEVARD, ROCHESTER, NYDATE: JANUARY 9,2024ARCHITECTURAL PLAN:BERGMEYER51 SLEEPER STREET, BOSTON, MADATE: OCTOBER 27, 2023LAST REVISED: JUNE 14, 2024MEP/FP PLANS:BLW ENGINEERS311 GREAT STREET, PO BOX 1551DATE: FEBRUARY 16, 2024LAST REVISED: JUNE 14, 2024TRAFFIC PLAN:GTS CONSULTING1396 WHITE BRIDGE RD, CHITTENANGO NYDATE: NOVEMBER 2023LIGHTING PLAN:BOSTON LIGHT SOURCE64 COMMERCIAL WHARF, BOSTON MADATE: MARCH 21, 2024LAST REVISED: MAY 1, 2024* THE ABOVE REFERENCED DOCUMENTS AREINCORPORATED BY REFERENCE AS PART OF THESEPLANS, HOWEVER, BOHLER ENGINEERING DOES NOTCERTIFY THE ACCURACY OF THE WORK REFERENCEDOR DERIVED FROM THESE DOCUMENTS, BY OTHERS.REFERENCESPROPOSED SITE PLANDOCUMENTSTHBC NY, LLCPROPOSEDMICROPRODUCTION BREWERYLOCATION OF SITE:3376 SOUTH BROADWAY, CITY OF SARATOGA SPRINGS SARATOGA COUNTY, NEW YORKMAP #178, BLOCK #2, LOT #15FORSHEET INDEXSHEET TITLENUMBERCOVER SHEETC-101GENERAL NOTES SHEETC-102DEMOLITION PLANC-201SITE LAYOUT PLANC-301GRADING & DRAINAGE PLANC-401UTILITY PLANC-501SOIL EROSION & SEDIMENT CONTROL PLANC-601SOIL EROSION & SEDIMENT CONTROL NOTES & DETAILSC-602DETAIL SHEETC-901DETAIL SHEETC-902DETAIL SHEETC-903DETAIL SHEETC-904TRAFFIC CONTROL PLANC-905TRAFFIC CONTROL PLANC-906LANDSCAPE LAYOUT PLANL-100LANDSCAPE MATERIALS PLANL-200LANDSCAPE PLANTING PLANL-300LANDSCAPE PLANTING ENLARGEMENTSL-301IRRIGATION PLANL-400LANDSCAPE SECTIONSL-500LANDSCAPE GENERAL NOTESL-600LANDSCAPE AMENITY DETAILSL-601LANDSCAPE AMENITY DETAILSL-602LANDSCAPE PLANTING DETAILSL-603REFERENCE PLANSLIGHTING PLAN (BY OTHERS)2 SHEETSALTA / NSPS LAND TITLE SURVEY1 SHEETGC-RGATEWAY COMMERCIAL - RURAL"HOMEWOOD SUITES HOTEL"GC-RGATEWAY COMMERCIAL - RURALPROP. BUILDING(±19,950 SF)PROP. PAVILION (±3,550 SF)PROP. PERGOLA (±3,550 SF) REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY12345678REVISION 8 -01/19/2024CLIENT COMMENTSSGSW02/02/2024CITY COMMENTSSGVR03/04/2024CITY COMMENTSSGSW03/20/2024CITY COMMENTSSGVR04/15/2024CITY AND TDECOMMENTSAKDSRW05/03/2024PRELIMINARY ISSUEFOR CONSTRUCTIONAKDSRW06/07/2024DOT AND SCSDCOMMENTSAKDSRW06/14/2024ADDENDUM 1AKDSRW06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORP:\2023\NYB230191.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\NYB230191.00-SPPD-0A----->LAYOUT: C-102 NOTEAD THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191SAG/AKDSRW11/30/2023NYB230191.00-SPPD-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK 2 - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comREFER TO EROSION AND SEDIMENTCONTROL NOTES & DETAILS SHEET FORTYPICAL EROSION NOTES AND DETAILSREFER TO LANDSCAPE NOTES &DETAILS SHEET FOR TYPICALLANDSCAPE NOTES AND DETAILSREFER TO LIGHTING PLAN (BY OTHERS)FOR TYPICAL LIGHTING NOTES ANDTABLESREFER TO SITE LAYOUT PLAN FORZONING ANALYSIS TABLE AND LANDUSE / ZONING INFORMATION & NOTESGENERAL DEMOLITION NOTES(REV. 1/2023)1.THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THEGENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIRENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS'SPECIFIC NOTES.2.THE CONTRACTOR MUST CONDUCT DEMOLITION/REMOVALS ACTIVITIES IN SUCH A MANNER AS TO ENSURE MINIMUM INTERFERENCE WITH ROADS,STREETS, SIDEWALKS, WALKWAYS, AND ALL OTHER ADJACENT FACILITIES. THE CONTRACTOR MUST OBTAIN ALL APPLICABLE PERMITS FROM THEAPPROPRIATE GOVERNMENTAL AUTHORITY(IES) PRIOR TO THE COMMENCEMENT OF ANY ROAD OPENING OR DEMOLITION ACTIVITIES IN ORADJACENT TO THE RIGHT-OF-WAY.3.WHEN DEMOLITION-RELATED ACTIVITIES IMPACT ROADWAYS AND/OR ROADWAY RIGHT-OF-WAY, THE CONTRACTOR MUST PROVIDE TRAFFICCONTROL AND GENERALLY ACCEPTED SAFE PRACTICES IN CONFORMANCE WITH THE CURRENT FEDERAL HIGHWAY ADMINISTRATION "MANUAL ONUNIFORM TRAFFIC CONTROL DEVICES" (MUTCD), AND THE FEDERAL, STATE, AND LOCAL REGULATIONS.4.THE DEMOLITION (AND/OR REMOVALS) PLAN IS INTENDED TO PROVIDE GENERAL INFORMATION AND TO IDENTIFY ONLY CONDITIONS REGARDINGITEMS TO BE DEMOLISHED, REMOVED, AND/OR TO REMAIN.4.1.THE CONTRACTOR MUST ALSO REVIEW ALL CONSTRUCTION DOCUMENTS AND INCLUDE WITHIN THE DEMOLITION ACTIVITIES ALL INCIDENTALWORK NECESSARY FOR THE CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.4.2.THIS PLAN IS NOT INTENDED TO AND DOES NOT PROVIDE DIRECTION REGARDING THE MEANS, METHODS, SEQUENCING, TECHNIQUES ANDPROCEDURES TO BE EMPLOYED TO ACCOMPLISH THE WORK. ALL MEANS, METHODS, SEQUENCING, TECHNIQUES AND PROCEDURES TO BE USEDMUST BE IN STRICT ACCORDANCE AND CONFORMANCE WITH ALL STATE, FEDERAL, LOCAL, AND JURISDICTIONAL REQUIREMENTS. THECONTRACTOR MUST COMPLY WITH ALL OSHA AND OTHER SAFETY PRECAUTIONS NECESSARY TO PROVIDE A SAFE WORK SITE FOR THECONTRACTOR AND THE PUBLIC.5.THE CONTRACTOR MUST PROVIDE ALL "METHODS AND MEANS" NECESSARY TO PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OF EXISTINGSTRUCTURES, AND ANY OTHER IMPROVEMENTS THAT ARE REMAINING ON OR OFF SITE. THE CONTRACTOR, AT THE CONTRACTOR'S SOLE COST, MUSTREPAIR ALL DAMAGE TO ALL ITEMS AND FEATURES THAT ARE TO REMAIN. CONTRACTOR MUST USE NEW MATERIAL FOR ALL REPAIRS. CONTRACTOR'SREPAIRS MUST INCLUDE THE RESTORATION OF ALL ITEMS AND FEATURES REPAIRED TO THEIR PRE-DEMOLITION CONDITION, OR BETTER. CONTRACTORMUST PERFORM ALL REPAIRS AT THE CONTRACTOR'S SOLE EXPENSE.6.THE PROFESSIONAL OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR JOB SITE SAFETY OR SUPERVISION. THE CONTRACTOR MUST PROCEED WITHTHE DEMOLITION IN A SYSTEMATIC AND SAFE MANNER, COMPLYING WITH ALL OSHA REQUIREMENTS, TO ENSURE PUBLIC AND CONTRACTOR SAFETYAND SAFETY TO ALL PROPERTY ON THE SITE OR ADJACENT OR NEAR TO THE SAME.7.THE CONTRACTOR IS RESPONSIBLE FOR JOB SITE SAFETY, WHICH MUST INCLUDE, BUT IS NOT LIMITED TO, THE INSTALLATION AND MAINTENANCE OFBARRIERS, FENCING, OTHER APPROPRIATE AND/OR NECESSARY SAFETY FEATURES AND ITEMS NECESSARY TO PROTECT THE PUBLIC FROM AREAS OFCONSTRUCTION AND CONSTRUCTION ACTIVITIES. THE CONTRACTOR MUST SAFEGUARD THE SITE AS NECESSARY TO PERFORM THE DEMOLITION INSUCH A MANNER AS TO PREVENT THE ENTRY OF ALL UNAUTHORIZED PERSONS AT ANY TIME, TO OR NEAR THE DEMOLITION AREA.8.PRIOR TO THE COMMENCEMENT OF ANY SITE ACTIVITY AND ANY DEMOLITION ACTIVITY, THE CONTRACTOR MUST, IN WRITING, RAISE ANY QUESTIONSCONCERNING THE ACCURACY OR INTENT OF THESE PLANS AND/OR SPECIFICATIONS, ALL CONCERNS OR QUESTIONS REGARDING THE APPLICABLESAFETY STANDARDS, AND/OR THE SAFETY OF THE CONTRACTOR AND/OR THIRD PARTIES IN PERFORMING THE WORK ON THIS PROJECT. ANY SUCHCONCERNS MUST BE CONVEYED TO THE PROFESSIONAL OF RECORD AND BOHLER, IN WRITING AND MUST ADDRESS ALL ISSUES AND ITEMSRESPONDED TO, BY THE PROFESSIONAL OF RECORD AND BY BOHLER, IN WRITING. ALL DEMOLITION ACTIVITIES MUST BE PERFORMED IN ACCORDANCEWITH THE REQUIREMENTS OF THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS, RULES,REQUIREMENTS, STATUTES, ORDINANCES AND CODES.9.THE CONTRACTOR MUST BECOME FAMILIAR WITH THE APPLICABLE UTILITY SERVICE PROVIDER REQUIREMENTS AND IS RESPONSIBLE FOR ALLCOORDINATION REGARDING UTILITY DEMOLITION AND/OR DISCONNECTION AS IDENTIFIED OR REQUIRED FOR THE PROJECT. THE CONTRACTOR MUSTPROVIDE THE OWNER WITH WRITTEN NOTIFICATION THAT THE EXISTING UTILITIES AND SERVICES HAVE BEEN TERMINATED, REMOVED AND/ORABANDONED IN ACCORDANCE WITH THE JURISDICTION AND UTILITY COMPANY REQUIREMENTS AND ALL OTHER APPLICABLE REQUIREMENTS, RULES,STATUTES, LAWS, ORDINANCES AND CODES.10.PRIOR TO COMMENCING ANY DEMOLITION, THE CONTRACTOR MUST:10.1.OBTAIN ALL REQUIRED PERMITS AND MAINTAIN THE SAME ON SITE FOR REVIEW BY THE PROFESSIONAL OF RECORD AND ALL PUBLIC AGENCIESWITH JURISDICTION THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK, AND DEMOLITION WORK.10.2.NOTIFY, AT A MINIMUM, THE MUNICIPAL ENGINEER, DESIGN ENGINEER, AND LOCAL SOIL CONSERVATION JURISDICTION, AT LEAST 72 BUSINESSHOURS PRIOR TO THE COMMENCEMENT OF WORK.10.3.INSTALL THE REQUIRED SOIL EROSION AND SEDIMENT CONTROL MEASURES PRIOR TO SITE DISTURBANCE, AND MAINTAIN SAID CONTROLS UNTILSITE IS STABILIZED10.4.IN ACCORDANCE WITH STATE LAW, THE CONTRACTOR MUST CALL THE STATE ONE-CALL DAMAGE PROTECTION SYSTEM FOR UTILITY MARK OUT, INADVANCE OF ANY EXCAVATION.10.5.LOCATE AND PROTECT ALL UTILITIES AND SERVICES, INCLUDING BUT NOT LIMITED TO GAS, WATER, ELECTRIC, SANITARY AND STORM SEWER,TELEPHONE, CABLE, FIBER OPTIC CABLE, ETC. WITHIN AND ADJACENT TO THE LIMITS OF PROJECT ACTIVITIES. THE CONTRACTOR MUST USE ANDCOMPLY WITH THE REQUIREMENTS OF THE APPLICABLE UTILITY NOTIFICATION SYSTEM TO LOCATE ALL UNDERGROUND UTILITIES.10.6.PROTECT AND MAINTAIN IN OPERATION, ALL ACTIVE UTILITIES AND SYSTEMS THAT ARE NOT BEING REMOVED DURING ANY DEMOLITIONACTIVITIES.10.7.ARRANGE FOR AND COORDINATE WITH THE APPLICABLE UTILITY SERVICE PROVIDER(S) FOR THE TEMPORARY OR PERMANENT TERMINATION OFSERVICE REQUIRED BY THE PROJECT PLANS AND SPECIFICATIONS REGARDING THE METHODS AND MEANS TO CONSTRUCT SAME. THESE ARE NOTTHE PROFESSIONAL OF RECORD'S OR BOHLER RESPONSIBILITY. IN THE EVENT OF ABANDONMENT, THE CONTRACTOR MUST PROVIDE THE UTILITYENGINEER AND OWNER WITH IMMEDIATE WRITTEN NOTIFICATION THAT THE EXISTING UTILITIES AND SERVICES HAVE BEEN TERMINATED ANDABANDONED IN ACCORDANCE WITH JURISDICTIONAL AND UTILITY COMPANY REQUIREMENTS.10.8.ARRANGE FOR AND COORDINATE WITH THE APPLICABLE UTILITY SERVICE PROVIDER(S) REGARDING WORKING "OFF-PEAK" HOURS OR ONWEEKENDS AS NECESSARY OR AS REQUIRED TO MINIMIZE THE IMPACT ON, OF, AND TO THE AFFECTED PARTIES. WORK REQUIRED TO BEPERFORMED "OFF-PEAK" IS TO BE PERFORMED AT NO ADDITIONAL COST TO THE OWNER.10.9.IN THE EVENT THE CONTRACTOR DISCOVERS ANY HAZARDOUS MATERIAL, THE REMOVAL OF WHICH IS NOT ADDRESSED IN THE PROJECT PLANSAND SPECIFICATIONS OR THE CONTRACT WITH THE OWNER/DEVELOPER, THE CONTRACTOR MUST IMMEDIATELY CEASE ALL WORK IN THE AREAOF DISCOVERY, AND IMMEDIATELY NOTIFY, IN WRITING AND VERBALLY, THE OWNER, PROFESSIONAL OF RECORD AND BOHLER, THE DISCOVERY OFSUCH MATERIALS TO PURSUE PROPER AND COMPLIANT REMOVAL OF SAME.11.THE CONTRACTOR MUST NOT PERFORM ANY EARTH MOVEMENT ACTIVITIES, DEMOLITION OR REMOVAL OF FOUNDATION WALLS, FOOTINGS, OROTHER MATERIALS WITHIN THE LIMITS OF DISTURBANCE, UNLESS SAME IS IN STRICT ACCORDANCE AND CONFORMANCE WITH THE PROJECT PLANSAND SPECIFICATIONS, OR PURSUANT TO THE WRITTEN DIRECTION OF THE OWNER'S STRUCTURAL OR GEOTECHNICAL ENGINEER.12.DEMOLITION ACTIVITIES AND EQUIPMENT MUST NOT USE OR INCLUDE AREAS OUTSIDE THE DEFINED PROJECT LIMIT LINE, WITHOUT SPECIFICWRITTEN PERMISSION AND AUTHORITY OF AND FROM THE OWNER AND ALL GOVERNMENTAL AGENCIES WITH JURISDICTION.13.THE CONTRACTOR MUST BACKFILL ALL EXCAVATION RESULTING FROM, OR INCIDENTAL TO, DEMOLITION ACTIVITIES. BACKFILL MUST BEACCOMPLISHED WITH APPROVED BACKFILL MATERIALS AND MUST BE SUFFICIENTLY COMPACTED TO SUPPORT ALL NEW IMPROVEMENTS AND MUSTBE PERFORMED IN COMPLIANCE WITH THE RECOMMENDATIONS AND GUIDANCE ARTICULATED IN THE GEOTECHNICAL REPORT. BACKFILLING MUSTOCCUR IMMEDIATELY AFTER DEMOLITION ACTIVITIES AND MUST BE PERFORMED SO AS TO PREVENT WATER ENTERING THE EXCAVATION. FINISHEDSURFACES MUST BE GRADED TO PROMOTE POSITIVE DRAINAGE. THE CONTRACTOR IS RESPONSIBLE FOR COMPACTION TESTING AND MUST SUBMITSUCH REPORTS AND RESULTS TO THE PROFESSIONAL OF RECORD AND THE OWNER.14.EXPLOSIVES MUST NOT BE USED WITHOUT PRIOR WRITTEN CONSENT FROM BOTH THE OWNER AND ALL APPLICABLE, NECESSARY AND REQUIREDGOVERNMENTAL AUTHORITIES. PRIOR TO COMMENCING ANY EXPLOSIVE PROGRAM AND/OR ANY DEMOLITION ACTIVITIES, THE CONTRACTOR MUSTENSURE AND OVERSEE THE INSTALLATION OF ALL OF THE REQUIRED PERMIT AND EXPLOSIVE CONTROL MEASURES THAT THE FEDERAL, STATE, ANDLOCAL GOVERNMENTS REQUIRE. THE CONTRACTOR IS ALSO RESPONSIBLE TO CONDUCT AND PERFORM ALL INSPECTION AND SEISMIC VIBRATIONTESTING THAT IS REQUIRED TO MONITOR THE EFFECTS ON ALL LOCAL STRUCTURES AND THE LIKE.15.IN ACCORDANCE WITH FEDERAL, STATE, AND/OR LOCAL STANDARDS, THE CONTRACTOR MUST USE DUST CONTROL MEASURES TO LIMIT AIRBORNEDUST AND DIRT RISING AND SCATTERING IN THE AIR. AFTER THE DEMOLITION IS COMPLETE, THE CONTRACTOR MUST CLEAN ALL ADJACENTSTRUCTURES AND IMPROVEMENTS TO REMOVE ALL DUST AND DEBRIS WHICH THE DEMOLITION OPERATIONS CAUSE. THE CONTRACTOR ISRESPONSIBLE FOR RETURNING ALL ADJACENT AREAS TO THEIR "PRE-DEMOLITION" CONDITION AT CONTRACTOR'S SOLE COST.16.PAVEMENT MUST BE SAW CUT IN STRAIGHT LINES. ALL DEBRIS FROM REMOVAL OPERATIONS MUST BE REMOVED FROM THE SITE AT THE TIME OFEXCAVATION. STOCKPILING OF DEBRIS OUTSIDE OF APPROVED AREAS WILL NOT BE PERMITTED, INCLUDING BUT NOT LIMITED TO, THE PUBLICRIGHT-OF-WAY.17.THE CONTRACTOR MUST MAINTAIN A RECORD SET OF PLANS WHICH INDICATES THE LOCATION OF EXISTING UTILITIES THAT ARE CAPPED, ABANDONEDIN PLACE, OR RELOCATED DUE TO DEMOLITION ACTIVITIES. THIS RECORD DOCUMENT MUST BE PREPARED IN A NEAT AND WORKMAN-LIKE MANNERAND TURNED OVER TO THE OWNER/DEVELOPER UPON COMPLETION OF THE WORK, ALL OF WHICH IS AT THE CONTRACTOR'S SOLE COST.18.THE CONTRACTOR MUST EMPTY, CLEAN AND REMOVE FROM THE SITE ALL UNDERGROUND STORAGE TANKS, IF ENCOUNTERED, IN ACCORDANCE WITHFEDERAL, STATE, COUNTY AND LOCAL REQUIREMENTS, PRIOR TO CONTINUING CONSTRUCTION IN THE AREA AROUND THE TANK WHICH EMPTYING,CLEANING AND REMOVAL ARE AT THE CONTRACTOR'S SOLE COST.19.THE CONTRACTOR MUST LOCATE AND CLEARLY DEFINE VERTICALLY AND HORIZONTALLY ALL ACTIVE AND INACTIVE UTILITY AND/OR SERVICESYSTEMS THAT ARE TO BE REMOVED. THE CONTRACTOR IS RESPONSIBLE TO PROTECT AND MAINTAIN ALL ACTIVE SYSTEMS THAT ARE NOT BEINGREMOVED/RELOCATED DURING SITE ACTIVITY.20.CONTRACTOR SHALL FIELD LOCATE EXISTING UTILITIES PRIOR TO CONSTRUCTION AND IF REQUIRED, DIG EXPLORATORY TEST PITS TO CONFIRMEXACT LOCATION AND DEPTH OF UTILITIES. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER WITH ANY CONFLICTS AS NEEDED TO COORDINATEFINAL LOCATION OF ALL PROPOSED IMPROVEMENTS.21.CONTRACTOR SHALL INSPECT ALL EXISTING UTILITY STRUCTURES THAT ARE TO REMAIN FOR THE PROJECTS RE-USE TO VERIFY SUITABILITY FORSAME. IF STRUCTURES CAN NOT BE REUSED THEN THE CONTRACTOR SHALL PROVIDE A NEW STRUCTURE. THE CONTRACTOR SHALL COORDINATESUCH WORK WITH THE APPLICABLE UTILITY PROVIDER.22.CONTRACTOR TO REMOVE ANY BUILDING FOUNDATION REMAINS OR ASSOCIATED IMPROVEMENTS, DELETERIOUS MATERIALS, AND/OR DEBRIS THATIMPEDE THE WORK SHOWN ON THESE PLANS.23.THE CONTRACTOR SHALL REVIEW THE PLANS VERSUS THE LOCATION OF EXISTING STRUCTURES, UTILITIES AND APPURTENANCES IN THE FIELD TOCONFIRM ACCURACY OF SAME AND VERIFY ITEMS TO BE REMOVED. THE CONTRACTOR SHALL CARRY COSTS FOR REMOVAL OF ANY EXISTINGSTRUCTURES, APPURTENANCES, AND UNDERGROUND UTILITIES, INCLUDING BUT NOT LIMITED TO, DRAIN, WATER, SEWER, STEAM, IRRIGATION, GAS,TELECOM AND ELECTRIC.24.THE CONTRACTOR SHALL MAINTAIN, ADJUST OR ABANDON EXISTING MONITORING WELLS IN ACCORDANCE WITH THE DIRECTION OF THEENVIRONMENTAL CONSULTANT (TYP.)25.WHERE THE LIMIT OF WORK COINCIDES WITH PROPERTY LINE, TREE LINE, PROPOSED SAWCUT OR COMBINATION THEREOF IT IS SHOWN ADJACENTTO THESE FEATURES FOR GRAPHICAL CLARITY.26.EXISTING TREES TO REMAIN ARE TO BE PROTECTED DURING CONSTRUCTION UNLESS CLEARLY INDICATED OTHERWISE. REASONABLE CARE ANDCAUTION SHALL BE TAKEN DURING CONSTRUCTION TO PREVENT DAMAGE AND SELECTIVE PRUNING MAY BE REQUIRED TO ENSURE THAT TREES DONOT CONFLICT WITH THE DEVELOPMENT.27.CONTRACTOR SHALL REPAIR/REPLACE ANY TRAFFIC LOOP DETECTORS THAT ARE DAMAGED DURING CONSTRUCTION WITHIN EXISTING ORPROPOSED RIGHTS OF WAYS. ANY SUCH WORK SHALL BE PERFORMED BY A LICENSED / DOT APPROVED SIGNAL CONTRACTOR. ANY DAMAGEDLOOPS OR OTHER SIGNAL EQUIPMENT SHALL BE REPAIRED IMMEDIATELY AFTER THE WORK IS COMPLETE. THE SIGNAL CONTRACTOR SHALL BEAVAILABLE TO MAKE ANY TEMPORARY SIGNAL CHANGES IF REQUESTED BY DOT AND/OR THE MUNICIPALITY.28.THE CONTRACTOR MUST FIELD VERIFY THE LOCATIONS WHERE PROPOSED UTILITIES CROSS EXISTING UNDERGROUND UTILITIES BY USING A TESTPIT TO DETERMINE THE EXACT SIZE, DEPTH AND LOCATION, PRIOR TO COMMENCEMENT OF CONSTRUCTION.29.CONTRACTOR SHALL LOCATE ANY EXISTING UTILITY SERVICES THAT ARE TO BE TERMINATED AT THE EXISTING MAIN AND/OR PROPERTY LINE. THESESERVICES ARE TO BE TERMINATED IN ACCORDANCE WITH MUNICIPAL / STATE TRANSPORTATION DEPARTMENT REQUIREMENTS.GENERAL DRAINAGE & UTILITY NOTES(REV. 1/2023)1.THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THEGENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIRENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS'SPECIFIC NOTES.2.LOCATIONS OF ALL EXISTING AND PROPOSED SERVICES ARE APPROXIMATE, AND THE CONTRACTOR MUST INDEPENDENTLY VERIFY AND CONFIRMTHOSE LOCATIONS AND SERVICES WITH LOCAL UTILITY COMPANIES PRIOR TO COMMENCING ANY CONSTRUCTION OR EXCAVATION. THE CONTRACTORMUST INDEPENDENTLY VERIFY AND CONFIRM ALL SANITARY CONNECTION POINTS AND ALL OTHER UTILITY SERVICE CONNECTION POINTS IN THEFIELD, PRIOR TO COMMENCING ANY CONSTRUCTION. THE CONTRACTOR MUST REPORT ALL DISCREPANCIES, ERRORS AND OMISSIONS IN WRITING, TOTHE PROFESSIONAL OF RECORD AND BOHLER.3.THE CONTRACTOR MUST VERTICALLY AND HORIZONTALLY LOCATE ALL UTILITIES AND SERVICES INCLUDING, BUT NOT LIMITED TO, GAS, WATER,ELECTRIC, SANITARY AND STORM, TELEPHONE, CABLE, FIBER OPTIC CABLE, ETC. WITHIN THE LIMITS OF DISTURBANCE OR WORK SPACE, WHICHEVER ISGREATER. THE CONTRACTOR MUST USE, REFER TO, AND COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE UTILITY NOTIFICATION SYSTEM TOLOCATE ALL OF THE UNDERGROUND UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ALL DAMAGE TO ANY EXISTING UTILITIES WHICHOCCUR DURING CONSTRUCTION, AT NO COST TO THE OWNER AND AT CONTRACTOR'S SOLE COST AND EXPENSE. THE CONTRACTOR MUST BEAR ALLCOSTS ASSOCIATED WITH DAMAGE TO ANY EXISTING UTILITIES WHICH OCCURS DURING CONSTRUCTION. 4.THE CONTRACTOR MUST FIELD VERIFY THE PROPOSED INTERFACE POINTS (CROSSINGS) WITH EXISTING UNDERGROUND UTILITIES BY USING A TEST PITTO CONFIRM EXACT DEPTH, PRIOR TO COMMENCEMENT OF CONSTRUCTION.5.STORMWATER ROOF DRAIN LOCATIONS ARE BASED ON ARCHITECTURAL PLANS. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING LOCATIONS OFSAME BASED UPON FINAL ARCHITECTURAL PLANS. 6.THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING SITE PLAN DOCUMENTS AND ARCHITECTURAL PLANS FOR EXACT BUILDING UTILITYCONNECTION LOCATIONS; GREASE TRAP REQUIREMENTS; AND DETAILS, DOOR ACCESS, AND EXTERIOR GRADING. THE ARCHITECT WILL DETERMINETHE UTILITY SERVICE SIZES. THE CONTRACTOR MUST COORDINATE INSTALLATION OF UTILITY SERVICES WITH THE INDIVIDUAL COMPANIES TO AVOIDCONFLICTS AND TO ENSURE THAT PROPER DEPTHS ARE ACHIEVED. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT INSTALLATION OF ALLIMPROVEMENTS COMPLIES WITH ALL UTILITY REQUIREMENTS OF THE APPLICABLE JURISDICTION AND REGULATORY AGENCIES AND ALL OTHERAPPLICABLE REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES AND, FURTHER, IS RESPONSIBLE FOR COORDINATING THE UTILITYTIE-INS/CONNECTIONS PRIOR TO CONNECTING TO THE EXISTING UTILITY/SERVICE. WHERE A CONFLICT(S) EXISTS BETWEEN THESE DOCUMENTS ANDTHE ARCHITECTURAL PLANS, OR WHERE ARCHITECTURAL PLAN UTILITY CONNECTION POINTS DIFFER, THE CONTRACTOR MUST IMMEDIATELY NOTIFYTHE PROFESSIONAL OF RECORD AND BOHLER, IN WRITING, AND PRIOR TO CONSTRUCTION, MUST RESOLVE SAME.7.ALL FILL, COMPACTION, AND BACKFILL MATERIALS REQUIRED FOR UTILITY INSTALLATION MUST BE EXACTLY AS PER THE RECOMMENDATIONSPROVIDED IN THE GEOTECHNICAL REPORT AND THE CONTRACTOR MUST COORDINATE SAME WITH THE APPLICABLE UTILITY COMPANYSPECIFICATIONS. WHEN THE PROJECT DOES NOT HAVE GEOTECHNICAL RECOMMENDATIONS, FILL AND COMPACTION MUST COMPLY WITHAPPLICABLE REQUIREMENTS AND SPECIFICATIONS. THE PROFESSIONAL OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR DESIGN OF TRENCHBACKFILL OR FOR COMPACTION REQUIREMENTS8.DURING THE INSTALLATION OF SANITARY, STORM, AND ALL UTILITIES, THE CONTRACTOR MUST MAINTAIN A CONTEMPORANEOUS AND THOROUGHRECORD OF CONSTRUCTION TO IDENTIFY THE AS-INSTALLED LOCATIONS OF ALL UNDERGROUND INFRASTRUCTURE. THE CONTRACTOR MUSTCAREFULLY NOTE ANY INSTALLATIONS THAT DEVIATE, IN ANY RESPECT, FROM THE INFORMATION CONTAINED IN THESE PLANS. THIS RECORD MUST BEKEPT ON A CLEAN COPY OF THE APPROPRIATE PLAN(S), WHICH THE CONTRACTOR MUST PROMPTLY PROVIDE TO THE OWNER IMMEDIATELY UPON THECOMPLETION OF WORK.9.THE CONTRACTOR MUST ENSURE THAT ALL UTILITY TRENCHES LOCATED IN EXISTING PAVED ROADWAYS INCLUDING SANITARY, WATER AND STORMSYSTEMS, ARE REPAIRED IN ACCORDANCE WITH REFERENCED MUNICIPAL, COUNTY AND OR STATE DOT DETAILS AS APPLICABLE. THE CONTRACTORMUST COORDINATE INSPECTION AND APPROVAL OF COMPLETED WORK WITH THE AGENCY WITH JURISDICTION OVER SAME.10.FINAL LOCATIONS OF PROPOSED UTILITY POLES, AND/ OR POLES TO BE RELOCATED ARE AT THE SOLE DISCRETION OF THE RESPECTIVE UTILITYCOMPANY, REGARDLESS OF WHAT THIS PLAN DEPICTS.11.WATER SERVICE MATERIALS, BURIAL DEPTH, AND COVER REQUIREMENTS MUST BE SPECIFIED BY THE LOCAL UTILITY COMPANY. THE CONTRACTORMUST CONTACT THE APPLICABLE MUNICIPALITY TO CONFIRM THE PROPER WATER METER AND VAULT, PRIOR TO COMMENCING CONSTRUCTION.12.THE TOPS OF EXISTING MANHOLES, INLET STRUCTURES, AND SANITARY CLEANOUT MUST BE ADJUSTED, AS NECESSARY, TO MATCH PROPOSEDFINISHED GRADES WITH NO TRIPPING OR SAFETY HAZARD IN ACCORDANCE WITH ALL APPLICABLE STANDARDS, REQUIREMENTS, RULES, STATUTES,LAWS, ORDINANCES AND CODES.13.THE CONTRACTOR'S PRICE FOR WATER AND SEWER SERVICE INSTALLATIONS MUST INCLUDE ALL FEES, COSTS, AND APPURTENANCES REQUIRED BYTHE UTILITY PROVIDER (AND OTHER AGENCIES HAVING JURISDICTION OVER THE WORK) TO PROVIDE FULL AND COMPLETE WORKING SERVICE,INCLUDING (BUT NOT LIMITED TO) NECESSARY FEES, TESTING, DISINFECTING, INSPECTIONS, ROAD OPENING & BACKFILL REQUIREMENTS, TRAFFICCONTROL AND SURETY BONDS AS DEFINED BY THE PROVIDER (AND OTHER AGENCIES HAVING JURISDICTION OVER THE WORK).14.ALL WORK ASSOCIATED WITH UTILITY POLES, OVERHEAD WIRES AND ANY/ALL APPURTENANCES SHALL BE COORDINATED BY THE GC WITH THELOCAL UTILITY COMPANIES PRIOR TO THE ORDERING OF ANY MATERIALS. THIS MAY INCLUDE BUT IS NOT LIMITED TO THE REMOVAL, INSTALLATION,RELOCATION OR PROTECTION OF ANY BRACING, GUY WIRES, OVERHEAD WIRES, ETC. AS MAY BE REQUIRED TO ACCOMMODATE THE PROJECT.15.SEWERS CONVEYING SANITARY FLOW, OR INDUSTRIAL FLOW MUST BE SEPARATED FROM WATER MAINS BY A DISTANCE OF AT LEAST 10 FEETHORIZONTALLY. IF SUCH LATERAL SEPARATION IS NOT POSSIBLE, THE PIPES MUST, AT A MINIMUM, BE IN SEPARATE TRENCHES WITH THE AT LEAST18 INCHES OF VERTICAL SEPARATION FROM THE BOTTOM OF THE WATER MAIN TO THE TOP OF THE SEWER LINE. WHERE APPROPRIATE SEPARATIONFROM A WATER MAIN IS NOT POSSIBLE, THE SEWER MUST BE ENCASED IN CONCRETE, OR CONSTRUCTED OF DUCTILE IRON PIPE USINGMECHANICAL OR SLIP-ON JOINTS FOR A DISTANCE OF AT LEAST 10 FEET ON EITHER SIDE OF THE CROSSING. IN ADDITION, ONE FULL LENGTH OFSEWER PIPE SHOULD BE LOCATED SO BOTH JOINTS WILL BE AS FAR FROM THE WATER LINE AS POSSIBLE. WHERE A WATER MAIN CROSSES UNDERA SANITARY SEWER, ADEQUATE STRUCTURAL SUPPORT FOR THE SANITARY SEWER MUST BE PROVIDED. ALL CROSSINGS SHALL BE IN ACCORDANCEWITH JURISDICTIONAL PERMITTING/UTILITY AUTHORITIES REGULATIONS.16.WHEN THESE PLANS INVOLVE MULTIPLE BUILDINGS, SOME OF WHICH MAY BE BUILT AT A LATER DATE, THE CONTRACTOR MUST EXTEND ALL UTILITYSERVICES, INCLUDING BUT NOT LIMITED TO STORM, SANITARY, UTILITIES, AND IRRIGATION LINES, TO A POINT AT LEAST FIVE (5) FEET BEYOND THEPAVED AREAS FOR WHICH THE CONTRACTOR IS RESPONSIBLE. THE CONTRACTOR MUST CAP ENDS OF INSTALLED UTILITIES AS APPROPRIATE, MARKUTILITY ENDS WITH MAGNETIC TRACER TAPE, MARK TERMINUS LOCATIONS WITH A 2X4 STAKE, AND MUST NOTE THE LOCATION OF ALL UTILITYSTUBS ON A CLEAN COPY OF THE PLAN. THIS RECORD DOCUMENT MUST BE PREPARED IN A NEAT AND WORKMAN-LIKE MANNER AND TURNED OVERTO THE OWNER/DEVELOPER UPON COMPLETION OF THE WORK, ALL OF WHICH IS AT THE CONTRACTOR'S SOLE COST.17.STORM AND SANITARY PIPE LENGTHS INDICATED ARE NOMINAL AND ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTUREUNLESS INDICATED ON THE PLANS OTHERWISE.18.UNLESS INDICATED OTHERWISE, ALL NEW UTILITIES/SERVICES, INCLUDING ELECTRIC, TELEPHONE, CABLE TV, ETC., MUST BE INSTALLEDUNDERGROUND. ALL NEW UTILITY SERVICES MUST BE INSTALLED IN ACCORDANCE WITH THE UTILITY SERVICE PROVIDER INSTALLATIONSPECIFICATIONS AND STANDARDS.19.SANITARY PIPE MUST BE POLYVINYL CHLORIDE (PVC) SDR 35 EXCEPT WHERE CLEARLY INDICATED OTHERWISE. SANITARY LATERAL(S) MUST BE PVCSDR 26 UNLESS CLEARLY INDICATED OTHERWISE.20.UNLESS CLEARLY INDICATED OTHERWISE, ALL STORM PIPE MUST BE REINFORCED CONCRETE PIPE (RCP) CLASS III WITH SILT/SOIL TIGHT JOINTS.WHEN HIGH-DENSITY POLYETHYLENE PIPE (HDPE) IS CALLED FOR ON THE PLANS, IT MUST CONFORM TO AASHTO M252 FOR PIPES 4" TO 10" AND TOAASHTO M294 FOR PIPES 12" TO 60" AND TYPE S (SMOOTH INTERIOR WITH ANGULAR CORRUGATIONS) WITH GASKET FOR SILT/SOIL TIGHT JOINT. PIPEFOR ROOF DRAIN CONNECTION MUST BE SDR 26 PVC OR SCHEDULE 40 UNLESS INDICATED OTHERWISE. HDPE PIPE JOINT GASKETS MUST BEPROVIDED AND CONFORM TO ASTM F477. DRAIN PIPE INSTALLED WITH OVER TEN (10) FEET OVER COVER AND/OR IN HIGH GROUNDWATERCONDITIONS SHALL BE SANITITE HP POLYPROPYLENE PIPE (PP), OR APPROVED EQUIVALENT.21.UNLESS CLEARLY INDICATED OTHERWISE ALL SANITARY PIPE MUST BE:21.1.FOR PIPES LESS THAN 12 FEET DEEP: POLYVINYL CHLORIDE (PVC) SDR 35 PER ASTM D3034.21.2.FOR PIPES GREATER THAN 12 FEET DEEP: POLYVINYL CHLORIDE (PVC) SDR 26 PER ASTM D3034.21.3.UNLESS LOCAL OR STATE BUILDING / PLUMBING CODE CLEARLY SPECIFIES DIFFERENTLY, SANITARY LATERALS MUST BE PVC SDR 26.21.4.FOR ALL UTILITY PIPING (INCLUDING DRAIN) WITHIN 10 FT OF A BUILDING, PIPE MATERIAL SHALL COMPLY WITH APPLICABLE LOCAL OR STATEBUILDING AND PLUMBING CODES. CONTRACTOR SHALL REFER TO PLUMBING ENGINEERING PLANS AND VERIFY PIPE MATERIAL WITH LOCALOFFICIAL PRIOR TO ORDERING OF MATERIALS.21.5.CONTRACTOR SHALL VERIFY THE CONNECTION OF EXTERIOR PIPING TO ANY FIXTURES (SUCH AS AN EXTERIOR GREASE INTERCEPTOR) OROTHER DRAINAGE SYSTEMS WITH LOCAL OFFICIALS FOR COMPLIANCE WITH APPLICABLE LOCAL OR STATE BUILDING AND PLUMBING CODESPRIOR TO ORDERING OF MATERIALS.22.WATER MAIN PIPING MUST BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS AND SPECIFICATIONS OF THE LOCAL WATER COMPANY. IN THEABSENCE OF SUCH REQUIREMENTS, WATER MAIN PIPING MUST BE CEMENT-LINED DUCTILE IRON (DIP) MINIMUM CLASS 52 THICKNESS. ALL PIPE ANDAPPURTENANCES MUST COMPLY WITH THE APPLICABLE AWWA STANDARDS IN EFFECT AT THE TIME OF APPLICATION.23.GAS METERS MUST BE PROTECTED AS REQUIRED BY THE JURISDICTIONAL GAS PROVIDER.GENERAL GRADING NOTES(REV. 1/2023)1.THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THEGENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIRENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS'SPECIFIC NOTES.2.SITE GRADING MUST BE PERFORMED IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS AND THE RECOMMENDATIONS SET FORTH IN THEGEOTECHNICAL REPORT AS REFERENCED IN THIS PLAN SET. IF NO GEOTECHNICAL REPORT HAS BEEN REFERENCED, THE CONTRACTOR MUST HAVE AGEOTECHNICAL ENGINEER PROVIDE WRITTEN SPECIFICATIONS AND RECOMMENDATIONS PRIOR TO THE CONTRACTOR COMMENCING THE GRADINGWORK. THE CONTRACTOR MUST FOLLOW THE REQUIREMENTS OF ALL MUNICIPAL, COUNTY, STATE, AND FEDERAL LAWS, WHICH HAVE JURISDICTIONOVER THIS PROJECT.3.THE CONTRACTOR IS REQUIRED TO SECURE ALL NECESSARY AND/OR REQUIRED PERMITS AND APPROVALS FOR ALL OFF-SITE MATERIAL SOURCES ANDDISPOSAL FACILITIES. THE CONTRACTOR MUST SUPPLY A COPY OF APPROVALS TO THE PROFESSIONAL OF RECORD, BOHLER AND THE OWNER PRIOR TOTHE CONTRACTOR COMMENCING ANY WORK.4.THE CONTRACTOR IS FULLY RESPONSIBLE FOR VERIFYING EXISTING TOPOGRAPHIC INFORMATION AND UTILITY INVERT ELEVATIONS PRIOR TOCOMMENCING ANY CONSTRUCTION. SHOULD DISCREPANCIES BETWEEN THE PLANS AND INFORMATION OBTAINED THROUGH FIELD VERIFICATIONS BEIDENTIFIED OR EXIST, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE PROFESSIONAL OF RECORD AND BOHLER, IN WRITING.5.THE CONTRACTOR IS RESPONSIBLE FOR REMOVING AND REPLACING ALL UNSUITABLE MATERIALS WITH SUITABLE MATERIALS AS SPECIFIED IN THEGEOTECHNICAL REPORT. THE CONTRACTOR MUST COMPACT ALL EXCAVATED OR FILLED AREAS IN STRICT ACCORDANCE WITH THE GEOTECHNICALREPORT'S GUIDANCE. MOISTURE CONTENT AT TIME OF PLACEMENT MUST BE SUBMITTED IN A COMPACTION REPORT PREPARED BY A QUALIFIEDGEOTECHNICAL ENGINEER, REGISTERED WITH THE STATE WHERE THE WORK IS PERFORMED. THIS REPORT MUST VERIFY THAT ALL FILLED AREAS ANDSUBGRADE AREAS WITHIN THE BUILDING PAD AREA AND AREAS TO BE PAVED HAVE BEEN COMPACTED IN ACCORDANCE WITH THESE PLANS,SPECIFICATIONS AND THE RECOMMENDATIONS SET FORTH IN THE GEOTECHNICAL REPORT AND ALL APPLICABLE REQUIREMENTS, RULES, STATUTES,LAWS, ORDINANCES AND CODES WHICH ARE IN EFFECT AND WHICH ARE APPLICABLE TO THE PROJECT. SUBBASE MATERIAL FOR SIDEWALKS, CURB, ORASPHALT MUST BE FREE OF ORGANICS AND OTHER UNSUITABLE MATERIALS. SHOULD SUBBASE BE DEEMED UNSUITABLE BY OWNER/DEVELOPER, OROWNER/DEVELOPER'S REPRESENTATIVE, SUBBASE MUST BE REMOVED AND FILLED WITH APPROVED FILL MATERIAL, COMPACTED AS THEGEOTECHNICAL REPORT DIRECTS. EARTHWORK ACTIVITIES INCLUDING, BUT NOT LIMITED TO, EXCAVATION, BACKFILL, AND COMPACTING MUSTCOMPLY WITH THE RECOMMENDATIONS IN THE GEOTECHNICAL REPORT AND ALL APPLICABLE REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCESAND CODES. EARTHWORK ACTIVITIES MUST COMPLY WITH THE STANDARD STATE DOT SPECIFICATIONS FOR ROADWAY CONSTRUCTION (LATESTEDITION) AND ANY AMENDMENTS OR REVISIONS THERETO.6.IN THE EVENT OF A DISCREPANCY(IES) AND/OR A CONFLICT(S) BETWEEN PLANS, OR RELATIVE TO OTHER PLANS, THE GRADING PLAN TAKESPRECEDENCE AND CONTROLS. THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE PROFESSIONAL OF RECORD AND BOHLER, IN WRITING, OF ANYDISCREPANCY(IES) AND/OR CONFLICT(S).7.THE CONTRACTOR IS RESPONSIBLE TO IMPORT FILL OR EXPORT EXCESS MATERIAL AS NECESSARY TO CONFORM TO THE PROPOSED GRADING, AND TOBACKFILL EXCAVATIONS FOR THE INSTALLATION OF UNDERGROUND IMPROVEMENTS.8.PROPOSED TOP OF CURB ELEVATIONS ARE GENERALLY 6" ABOVE PAVEMENT GRADE UNLESS OTHERWISE NOTED.9.THE CONTRACTOR MUST CONFIRM AND ENSURE THAT AS CONSTRUCTED IMPROVEMENTS CREATE THE FOLLOWING MINIMUM SLOPES (EXCEPTWHERE ADA REQUIREMENTS LIMIT THEM): 1.0% ON ALL CONCRETE SURFACES, 1.5% ON ASPHALT SURFACES, 1.5% IN LANDSCAPED AREAS AND 0.75%SLOPE AGAINST ALL ISLANDS, GUTTERS, AND CURBS TO PROVIDE POSITIVE DRAINAGE.10.WHERE RETAINING WALLS ARE IDENTIFIED ON THE PLANS, TOP AND BOTTOM OF WALL ELEVATIONS (TW & BW) REPRESENT THE PROPOSED FINISHEDGRADE AT THE FACE OF THE TOP AND BOTTOM OF THE WALL AND DO NOT REPRESENT THE ELEVATION OF THE PROPOSED WALL (INCLUDING THECAP UNIT OR FOOTING). WALL FOOTINGS/FOUNDATION ELEVATIONS ARE NOT IDENTIFIED HEREIN AND ARE TO BE SET/DETERMINED BY THECONTRACTOR OR WALL DESIGNER, AND MUST BE SET BASED UPON FINAL STRUCTURAL DESIGN SHOP DRAWINGS PREPARED BY THE APPROPRIATEPROFESSIONAL LICENSED IN THE STATE WHERE THE CONSTRUCTION OCCURS. THE CONTRACTOR MUST ENSURE THAT THERE ARE NO UTILITIES ONTHE PASSIVE SIDE OF THE RETAINING WALL. NO EXCAVATION MAY BE PERFORMED ON THE PASSIVE SIDE OF THE RETAINING WALL WITHOUTAPPROPRIATELY AND SAFELY SUPPORTING THE WALL IN ACCORDANCE WITH THE STANDARD OF CARE AND ALL APPLICABLE RULES, REGULATIONS,CODES, ORDINANCES, LAWS AND STATUTES.11.MSE OR GRAVITY BLOCK WALLS SHALL BE CONSTRUCTED SUCH THAT UPON COMPLETION OF CONSTRUCTION THERE IS NO UNFINISHED SURFACEOR LIFTING RINGS VISIBLE (E.G. USE OF FINISHED TOP BLOCK OR CAP STONES)12.STORMWATER RUNOFF WITHIN PROPERTY MUST BE COLLECTED ON-SITE WITH NO OVERLAND RUNOFF ONTO THE RIGHT-OF-WAY OR ADJACENTPROPERTIES TO THE MAXIMUM EXTENT POSSIBLE OR IN THE MANNER SHOWN ON THE CONSTRUCTION DRAWINGS. STORMWATER RUNOFF ONTOADJACENT PROPERTIES SHALL BE CONTROLLED AS TO NOT ADVERSELY IMPACT SAID PROPERTIES.13.BEFORE COMMENCING GRADING WORK, CONTRACTOR SHALL SUBMIT SAMPLES OF ALL NATIVE AND IMPORTED MATERIALS WITH THEIR INTENDEDFOR STRUCTURAL USES TO THE GEOTECHNICAL ENGINEER OF RECORD.14.REFER TO GENERAL NOTES SHEET FOR ADDITIONAL ADA GUIDELINES AND REQUIREMENTS.15.FOR ALL RETAINING WALLS (CT USE 3, ALL OTHER OFFICES USE 4) FEET OR GREATER IN HEIGHT:15.1.THE OWNER OR THE OWNER'S CONTRACTOR IS TO PROVIDE A SITE-SPECIFIC RETAINING WALL DESIGN PREPARED BY THE APPROPRIATEPROFESSIONAL LICENSED (E.G. STRUCTURAL ENGINEER) IN THE STATE WHERE THE CONSTRUCTION OCCURS. SOIL TYPES, WATER TABLEELEVATION, EXISTING & PROPOSED SURROUNDING IMPROVEMENTS/CONDITIONS (INCLUDING BUT NOT LIMITED TO SLOPES, DRIVE AISLES,ROADS, FENCING, GUIDERAILS, UTILITIES, DRAINAGE FACILITIES, STRUCTURES, FOUNDATIONS), LIVE LOADS AND OTHER SITE AMENITIES THATCOULD HAVE AN INFLUENCE OR IMPACT ON THE RETAINING WALL(S) CONSTRUCTABILITY AND/OR LONGEVITY SHALL BE CONSIDERED ANDINCORPORATED INTO THE RETAINING WALL DESIGN AS WELL AS THE GLOBAL STABILITY ANALYSIS.15.2.PEER REVIEW AND GLOBAL STABILITY ANALYSIS OF THE RETAINING WALL DESIGN MUST BE COMPLETED BY THE OWNER'S GEOTECHNICALENGINEER TO CERTIFY THE DESIGN MEETS INDUSTRY STANDARDS FOR FACTOR OF SAFETY. SOIL TYPES, WATER TABLE ELEVATION ANDDESIGN PROPERTIES AS NOTED ABOVE SHALL BE FIELD CONFIRMED AND APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO WALLCONSTRUCTION.16.CONTRACTOR SHALL INSTALL CONCRETE CURB ALONG FACE OF BUILDING / WALL AS SHOWN TO PROVIDE CONSISTENT WIDTH ALONG LENGTH OFPROPOSED ACCESSIBLE RAMP AND RAMP LANDING TO MEET ADA/AAB REQUIREMENTS.17.CONTRACTOR SHALL REVIEW RETAINING WALL LOCATIONS VERSUS APPLICABLE STATE AND LOCAL CODES AND PROVIDE FALL PROTECTION (E.G.FENCING OR RAILING) IN ACCORDANCE WITH SAID CODE.18.CONTRACTOR SHALL COORDINATE WITH OWNER/OPERATOR TO REVIEW EXISTING DEPRESSIONS WITHIN EXISTING PAVEMENT AREAS TO REMAINAND SHALL CONFIRM THAT THE SCOPE OF WORK SHALL PROVIDE POSITIVE DRAINAGE BY FIXING ANY EXISTING AREAS OF PONDING.19.BEFORE COMMENCING GRADING WORK, CONTRACTOR SHALL SUBMIT SAMPLES OF ALL NATIVE AND IMPORTED MATERIALS WITH THEIR INTENDEDFOR STRUCTURAL USES TO THE GEOTECHNICAL ENGINEER OF RECORD.GENERAL SITE NOTES(REV. 1/2020)1.THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THEGENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIRENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS'SPECIFIC NOTES.2.PRIOR TO THE COMMENCEMENT OF GENERAL CONSTRUCTION, THE CONTRACTOR MUST INSTALL SOIL EROSION CONTROL AND ANY STORMWATERPOLLUTION PREVENTION PLAN (SWPPP) MEASURES NECESSARY, AS INDICATED ON THE APPROVED SOIL EROSION AND SEDIMENT CONTROL PLAN ANDIN ACCORDANCE WITH APPLICABLE AND/OR APPROPRIATE AGENCIES' GUIDELINES TO PREVENT SEDIMENT AND/OR LOOSE DEBRIS FROM WASHINGONTO ADJACENT PROPERTIES OR THE RIGHT OF WAY.3.ALL DIRECTIONAL/TRAFFIC SIGNING AND PAVEMENT STRIPING MUST CONFORM TO THE LATEST STANDARDS OF THE MANUAL ON UNIFORM TRAFFICCONTROL DEVICES (MUTCD) AND ANY APPLICABLE STATE OR LOCALLY APPROVED SUPPLEMENTS, GUIDELINES, RULES, REGULATIONS, STANDARDS ANDTHE LIKE.4.THE LOCATIONS OF PROPOSED UTILITY POLES AND TRAFFIC SIGNS SHOWN ON THE PLANS ARE SCHEMATIC AND PRELIMINARY. THE CONTRACTOR ISSOLELY RESPONSIBLE FOR FIELD-VERIFYING THEIR LOCATION. THE CONTRACTOR MUST COORDINATE THE RELOCATION OF TRAFFIC SIGNS WITH THEENTITY WITH JURISDICTION OVER THE PROJECT.5.ALL DIMENSIONS SHOWN ARE TO BOTTOM FACE OF CURB, EDGE OF PAVEMENT, OR EDGE OF BUILDING, EXCEPT WHEN DIMENSION IS TO A PROPERTYLINE, STAKE OUT OF LOCATIONS OF INLETS, LIGHT POLES, ETC. MUST BE PERFORMED IN STRICT ACCORDANCE WITH THE DETAILS, UNLESS NOTEDCLEARLY OTHERWISE.6.WHEN APPLICABLE, OWNER/ OPERATOR MUST FILE THE NOI FOR NPDES PERMITS AT APPROPRIATE AND/OR REQUIRED TIMEFRAMES BASED UPONTHE DESIRED START OF CONSTRUCTION. LAND DISTURBING ACTIVITIES MUST NOT COMMENCE UNTIL APPROVAL TO DO SO HAS BEEN RECEIVEDFROM GOVERNING AUTHORITIES (INCLUDING STORMWATER POLLUTION PREVENTION PLAN). THE CONTRACTOR MUST STRICTLY ADHERE TO THEAPPROVED SWPPP PLAN DURING CONSTRUCTION OPERATIONS (IF PROVIDED).7.ALL CONCRETE MUST BE AIR ENTRAINED AND INCLUDE THE MINIMUM COMPRESSIVE STRENGTH OF JURISDICTIONAL STANDARD PSI AT 28 DAYS (OR4,000 PSI) UNLESS OTHERWISE NOTED ON THE PLANS, DETAILS AND/OR GEOTECHNICAL REPORT.8.THE CONTRACTOR MUST FILE SITE SIGNAGE APPLICATION OR PERMIT UNDER SEPARATE APPLICATION UNLESS DONE SO AS PART OFJURISDICTIONAL PERMITTING PROCEDURES.9.THE CONTRACTOR MUST REPAIR OR REPLACE, AT THE CONTRACTOR'S SOLE COST AND EXPENSE, ALL SIDEWALKS, CURBS, PAVEMENT MARKINGS,AND PAVEMENT DAMAGED BY CONSTRUCTION ACTIVITIES WHETHER SPECIFIED ON THIS PLAN OR NOT.10.WORK WITHIN THE RIGHT-OF-WAY MUST BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE REQUIREMENTS AND STANDARDS OF THEDEPARTMENT OF PUBLIC WORKS, ENGINEERING DEPARTMENT, HIGHWAY DIVISION, AND/OR STATE DOT HIGHWAY DEPARTMENT.11.WHERE RETAINING WALLS ARE IDENTIFIED ON THE PLANS, TOP AND BOTTOM OF WALL WIDTHS DO NOT REPRESENT THE ACTUAL WIDTH OF THEPROPOSED WALL, RATHER THEY ARE AN ASSUMPTION BASED ON WALL TYPE AND WALL HEIGHT. WALL FOOTINGS AND /OR FOUNDATIONS ARE NOTIDENTIFIED HEREIN AND ARE TO BE SET/DETERMINED BY THE CONTRACTOR OR WALL DESIGNER, AND MUST BE SET BASED UPON FINALSTRUCTURAL DESIGN SHOP DRAWINGS PREPARED BY THE APPROPRIATE PROFESSIONAL LICENSED IN THE STATE WHERE THE CONSTRUCTIONOCCURS. THE CONTRACTOR MUST ENSURE THAT AN APPROPRIATELY LICENSED PROFESSIONAL DESIGNS ALL WALLS SHOWN HEREON AND PRIORTO CONSTRUCTION. REFER TO GRADING NOTES REGARDING RETAINING WALL DESIGN.12.CONTRACTOR IS CAUTIONED OF EXISTING UTILITY SERVICES TO REMAIN IN PROXIMITY TO PROPOSED BOLLARDS AND SIGNS. CONTRACTOR SHALLPROVIDE FIELD MODIFICATION LOCATIONS OF BOLLARDS AND BOLLARDS WITH SIGNAGE AS NEEDED TO AVOID CONFLICTS WITH EXISTING UTILITYSERVICES TO REMAIN.ADA INSTRUCTIONS TO CONTRACTOR(REV. 1/2023)1.ALL ACCESSIBLE (A.K.A. ADA) COMPONENTS AND ACCESSIBLE ROUTES MUST BE CONSTRUCTED TO MEET, AT A MINIMUM, THE MORE STRINGENT OF:(A) THE REQUIREMENTS OF THE "AMERICANS WITH DISABILITIES ACT" (ADA) CODE (42 U.S.C. § 12101 ET SEQ. AND 42 U.S.C. § 4151 ET SEQ.); AND (B)ANY APPLICABLE LOCAL AND STATE GUIDELINES, AND ANY AND ALL AMENDMENTS TO BOTH, WHICH ARE IN EFFECT WHEN THESE PLANS WERECOMPLETED.2.THE CONTRACTOR MUST REVIEW ALL DOCUMENTS REFERENCED IN THESE NOTES FOR ACCURACY, COMPLIANCE AND CONSISTENCY WITH INDUSTRYGUIDELINES.3.THE CONTRACTOR MUST EXERCISE APPROPRIATE CARE AND PRECISION IN CONSTRUCTION OF ACCESSIBLE (ADA) COMPONENTS AND ACCESSIBLEROUTES FOR THE SITE. FINISHED SURFACES ALONG THE ACCESSIBLE ROUTE OF TRAVEL FROM PARKING SPACES, PUBLIC TRANSPORTATION, PEDESTRIANACCESS, AND INTER-BUILDING ACCESS, TO POINTS OF ACCESSIBLE BUILDING ENTRANCE/EXIT, MUST COMPLY WITH THE ACCESSIBLE GUIDELINES ANDREQUIREMENTS WHICH INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING:3.1.ACCESSIBLE PARKING SPACES AND ACCESS AISLES SLOPES MUST NOT EXCEED 1:50 (2.0%) IN ANY DIRECTION.3.2.PATH OF TRAVEL ALONG ACCESSIBLE ROUTE MUST PROVIDE A 36-INCHES MINIMUM WIDTH (48-INCHES PREFERRED), OR AS SPECIFIED BY THEGOVERNING AGENCY. UNOBSTRUCTED WIDTH OF TRAVEL (CAR OVERHANGS AND/OR HANDRAILS) MUST NOT REDUCE THIS MINIMUM WIDTH.THE SLOPE MUST NOT EXCEED 1:20 (5.0%) IN THE DIRECTION OF TRAVEL AND MUST NOT EXCEED 1:50 (2.0%) IN CROSS SLOPE. WHERE ACCESSIBLEPATH OF TRAVEL IS GREATER THAN 1:20 (5.0%), AN ACCESSIBLE RAMP MUST BE PROVIDED. ALONG THE ACCESSIBLE PATH OF TRAVEL, OPENINGSMUST NOT EXCEED 1/2-INCH IN WIDTH. VERTICAL CHANGES OF UP TO 1/2-INCH ARE PERMITTED ONLY IF THEY INCLUDES A 1/4-INCH BEVEL AT ASLOPE NOT STEEPER THAN 1:2. NO VERTICAL CHANGES OVER 1/4-INCH ARE PERMITTED.3.3.ACCESSIBLE RAMPS MUST NOT EXCEED A SLOPE OF 1:12 (8.3%) AND A RISE OF 30-INCHES. LEVEL LANDINGS MUST BE PROVIDED AT EACH END OFACCESSIBLE RAMPS. LANDING MUST PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURES, AND MUST NOT EXCEED 1:50 (2.0%) SLOPE IN ANYDIRECTION. RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT LANDINGS MUST HAVE A CLEAR LANDING OF A MINIMUM OF 60-INCHES BY60-INCHES. HAND RAILS ON BOTH SIDES OF THE RAMP MUST BE PROVIDED ON AN ACCESSIBLE RAMP WITH A RISE GREATER THAN 6-INCHES.3.4.ACCESSIBLE CURB RAMPS MUST NOT EXCEED A SLOPE OF 1:12 (8.3%). WHERE FLARED SIDES ARE PROVIDED, THEY MUST NOT EXCEED 1:10 (10%)SLOPE. LEVEL LANDING MUST BE PROVIDED AT RAMPS TOP AT A MINIMUM OF 36-INCHES LONG (48-INCHES PREFERRED). IN ALTERATIONS, WHENTHERE IS NO LANDING AT THE TOP, FLARE SIDES SLOPES MUST NOT EXCEED A SLOPE OF 1:12 (8.3%).3.5.DOORWAY LANDINGS AREAS MUST BE PROVIDED ON THE EXTERIOR SIDE OF ANY DOOR LEADING TO AN ACCESSIBLE PATH OF TRAVEL. THISLANDING MUST BE SLOPED AWAY FROM THE DOOR NO MORE THAN 1:50 (2.0%) FOR POSITIVE DRAINAGE. THIS LANDING AREA MUST BE NOFEWER THAN 60-INCHES (5 FEET) LONG, EXCEPT WHERE OTHERWISE CLEARLY PERMITTED BY ACCESSIBLE STANDARDS FOR ALTERNATIVEDOORWAY OPENING CONDITIONS. (SEE ICC/ANSI A117.1-2009 AND OTHER REFERENCES INCORPORATED BY CODE).3.6.WHEN THE PROPOSED CONSTRUCTION INVOLVES RECONSTRUCTION, MODIFICATION, REVISION OR EXTENSION OF OR TO ACCESSIBLECOMPONENTS FROM EXISTING DOORWAYS OR SURFACES, THE CONTRACTOR MUST VERIFY ALL EXISTING ELEVATIONS SHOWN ON THE PLAN.NOTE THAT TABLE 405.2 OF THE DEPARTMENT OF JUSTICE'S ADA STANDARDS FOR ACCESSIBLE DESIGN ALLOWS FOR STEEPER RAMP SLOPES, INRARE CIRCUMSTANCES. THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE PROFESSIONAL OF RECORD AND BOHLER, IN WRITING, OF ANYDISCREPANCIES AND/OR FIELD CONDITIONS THAT DIFFER IN ANY WAY OR IN ANY RESPECT FROM WHAT IS SHOWN ON THE PLANS BEFORECOMMENCING ANY WORK. CONSTRUCTED IMPROVEMENTS MUST FALL WITHIN THE MAXIMUM AND MINIMUM LIMITATIONS IMPOSED BY THEBARRIER FREE REGULATIONS AND THE ACCESSIBLE GUIDELINES.3.7.THE CONTRACTOR MUST VERIFY ALL OF THE SLOPES OF THE CONTRACTOR'S FORMS PRIOR TO POURING CONCRETE. IF ANY NON-CONFORMANCEEXISTS OR IS OBSERVED OR DISCOVERED, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE PROFESSIONAL OF RECORD AND BOHLER, INWRITING, PRIOR TO POURING CONCRETE. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL COSTS TO REMOVE, REPAIR AND/OR REPLACENON-CONFORMING CONCRETE AND/OR PAVEMENT SURFACES.4.IT IS STRONGLY RECOMMENDED THAT THE CONTRACTOR REVIEW THE INTENDED CONSTRUCTION TO ENSURE SAME IS CONSISTENT WITH THE LOCALBUILDING CODE PRIOR TO COMMENCING CONSTRUCTION.SEWER PIPEEXISTINGPROPOSEDSEWER FORCE MAINEXISTINGPROPOSEDELECTRICEXISTINGPROPOSEDTELECOMMUNICATIONSEXISTINGPROPOSEDCABLE TVEXISTINGPROPOSEDGASEXISTINGPROPOSEDWATEREXISTINGPROPOSEDTYPICAL LINE TYPE LEGENDPROPERTY LINEEXISTINGPROPOSEDADJACENT PROPERTYLINEEXISTINGPROPOSEDRIGHT-OF-WAY LINEEXISTINGPROPOSEDSETBACK OR BUFFEREXISTINGPROPOSEDEASEMENT LINEEXISTINGPROPOSEDWETLAND BOUNDARYEXISTINGPROPOSEDWETLAND BUFFEREXISTINGPROPOSEDWATER WAY BOUNDARYEXISTINGPROPOSEDWATERWAY BUFFEREXISTINGPROPOSEDWETLAND OR WATERWAYFLAGEXISTINGRIGHT-OF-WAY CENTEROR BASE LINEEXISTINGPROPOSEDAPPROX. LIMIT OF WORKOR DISTURBANCEEXISTINGPROPOSEDAPPROX. SAWCUT LINEEXISTINGPROPOSEDTREE LINEEXISTINGPROPOSEDSURFACE ORSUBSURFACE BASINEXISTINGPROPOSEDOVERHEAD WIRESEXISTINGPROPOSEDCURBINGEXISTINGPROPOSED CC/BCC MONOLITHIC VGC SGC TRANS/FLUSH CCBFENCE OR RAILINGEXISTINGPROPOSED CHAIN LINK STOCKADE RAILINGRETAINING WALLEXISTINGPROPOSEDCONTOURSEXISTINGPROPOSEDSWALEEXISTINGPROPOSEDBERMEXISTINGPROPOSEDRIDGEEXISTINGPROPOSEDDRAIN PIPEEXISTINGPROPOSED4950OHOHOHSSLFMFMFMEEETTTCCCGGGWWWABBREVIATIONSKEYDESCRIPTIONAG / ABVGABOVE GROUNDARCHARCHITECTBCBACK OF CURBBCCBITUMINOUS CONCRETE CURBBMBENCHMARKBOCBOTTOM OF CURBBWBOTTOM OF WALLBLDGBUILDINGCCCONCRETE CURBCCBCAPE COD BERMCONC.CONCRETEDECDECORATIVE°DEGREEDEPDEPRESSEDØ / DIADIAMETERDMHDRAIN MANHOLEDIPDUCTILE IRON PIPEECCEXTRUDED CONCRETE CURBEOPEDGE OF PAVEMENTELEVELEVATIONEXIST.EXISTINGFESFLARED END SECTIONFFEFINISH FLOOR ELEVATIONGCGENERAL CONTRACTORGRTGRATEHDPEHIGH DENSITY POLYETHYLENE PIPEHPHIGH POINTINTINTERSECTIONINVINVERTL.S.A.LANDSCAPE AREALODLIMIT OF DISTURBANCELOWLIMIT OF WORKLFLINEAR FOOT / FEETLPLOW POINTMAXMAXIMUMMEPMECHANICAL, ELECTRICAL,PLUMBINGMEMEET OR MATCH EXISTINGMINMINIMUMNo. / #NUMBER±PLUS OR MINUSPCPOINT OF CURVATUREPIPOINT OF INTERSECTIONPTPOINT OF TANGENCYPVIPOINT OF VERTICAL INTERSECTIONPVCPOLYVINYL CHLORIDE PIPEPROP.PROPOSEDRRADIUS OR RADIIRCPREINFORCED CONCRETE PIPER.O.W.RIGHT-OF-WAYSANSANITARYSMHSEWER MANHOLESSLOPESFSQUARE FOOTSGCSLOPED GRANITE CURBSTASTATIONSTMSTORMTBRTO BE REMOVEDTBR/RTO BE REMOVED AND REPLACEDTCTOP OF CURBTWTOP OF WALLTPFTREE PROTECTION FENCETRANSTRANSITIONTYP.TYPICALUG / UNDGUNDERGROUNDV.I.F.VERIFY IN FIELDVGCVERTICAL GRANITE CURBWWIDTHC-102GENERALNOTESSHEETGENERAL NOTES(REV. 1/2023)1.THESE PLANS ARE SOLELY BASED ON INFORMATION THE OWNER AND OTHERS PROVIDED TO BOHLER ENGINEERING AND LANDSCAPEARCHITECTURE NY, PLLC (HEREIN “BOHLER”) PRIOR TO THE DATE ON WHICH THE PROFESSIONAL OF RECORD AND BOHLER PREPARED THESEPLANS. THE CONTRACTOR MUST FIELD VERIFY ALL EXISTING CONDITIONS AND IMMEDIATELY NOTIFY BOHLER , IN WRITING, IF ANY ACTUAL SITECONDITIONS DIFFER FROM THOSE SHOWN ON THESE PLANS, OR IF THE PROPOSED WORK CONFLICTS WITH ANY OTHER SITE FEATURES.2.THE CONTRACTOR MUST STRICTLY COMPLY WITH THESE NOTES AND ALL SPECIFICATIONS/REPORTS CONTAINED HEREIN. THE CONTRACTOR MUSTENSURE THAT ALL SUBCONTRACTORS FULLY AND COMPLETELY CONFORM TO AND COMPLY WITH THESE REQUIREMENTS, THESE NOTES, AND THEREQUIREMENTS ARTICULATED IN THE NOTES CONTAINED IN ALL THE OTHER DRAWINGS THAT COMPRISE THE PLAN SET OF DRAWINGS. ADDITIONALNOTES AND SPECIFIC PLAN NOTES MAY BE FOUND ON THE INDIVIDUAL PLANS. THESE GENERAL NOTES APPLY TO THIS ENTIRE DOCUMENT PACKAGE.IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW ALL CONSTRUCTION CONTRACT DOCUMENTS INCLUDING, BUT NOT LIMITED TO, ALL OF THEDRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THE PROJECT WORK SCOPE, PRIOR TO THE INITIATION AND COMMENCEMENT OFCONSTRUCTION.3.PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE CONTRACTOR MUST CONFIRM WITH THE PROFESSIONAL OF RECORD AND BOHLER THATTHE LATEST EDITION OF THE DOCUMENTS AND/OR REPORTS REFERENCED WITHIN THE PLAN REFERENCES ARE BEING USED FOR CONSTRUCTION.THIS IS THE CONTRACTOR'S SOLE AND COMPLETE RESPONSIBILITY.4.PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE CONTRACTOR MUST ENSURE THAT ALL REQUIRED PERMITS AND APPROVALS HAVE BEENOBTAINED. NO CONSTRUCTION OR FABRICATION IS TO BEGIN UNTIL THE CONTRACTOR HAS RECEIVED AND THOROUGHLY REVIEWED THECONDITIONS OF APPROVAL TO ALL PLANS AND OTHER DOCUMENTS REVIEWED AND APPROVED BY THE PERMITTING AUTHORITIES AND HAS ALSOCONFIRMED THAT ALL NECESSARY AND REQUIRED PERMITS HAVE BEEN OBTAINED. THE CONTRACTOR MUST HAVE COPIES OF ALL PERMITS ANDAPPROVALS ON SITE AT ALL TIMES.5.THE CONTRACTOR MUST ENSURE THAT ALL WORK IS PERFORMED IN ACCORDANCE WITH THESE PLANS, SPECIFICATIONS/REPORTS ANDCONDITIONS OF APPROVAL, AND ALL APPLICABLE REQUIREMENTS, RULES, REGULATIONS, STATUTORY REQUIREMENTS, CODES, LAWS ANDSTANDARDS OF ALL GOVERNMENTAL ENTITIES WITH JURISDICTION OVER THIS PROJECT, AND ALL PROVISIONS IN AND CONDITIONS OF THECONSTRUCTION CONTRACT WITH THE OWNER/DEVELOPER INCLUDING ALL EXHIBITS, ATTACHMENTS AND ADDENDA TO SAME.6.PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE CONTRACTOR MUST COORDINATE THE BUILDING LAYOUT BY CAREFULLY REVIEWING THEMOST CURRENT ARCHITECTURAL, CIVIL AND STRUCTURAL CONSTRUCTION DOCUMENTS (INCLUDING, BUT NOT LIMITED TO, MECHANICAL,ELECTRICAL, PLUMBING AND FIRE SUPPRESSION PLANS, WHERE APPLICABLE). THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE OWNER,ARCHITECT AND PROFESSIONAL OF RECORD AND BOHLER, IN WRITING, OF ANY CONFLICTS, DISCREPANCIES OR AMBIGUITIES WHICH EXISTBETWEEN THESE PLANS AND ANY OTHER PLANS THAT COMPRISE THE CONSTRUCTION DOCUMENTS.7.CONTRACTOR MUST REFER TO AND ENSURE COMPLIANCE WITH THE APPROVED ARCHITECTURAL/BUILDING PLANS OF RECORD FOR EXACTLOCATIONS AND DIMENSIONS OF ENTRY/EXIT POINTS, ELEVATIONS, PRECISE BUILDING DIMENSIONS, AND EXACT BUILDING UTILITY LOCATIONS.8.THE CONTRACTOR MUST FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS SHOWN ON THESE PLANS, PRIOR TO THE COMMENCEMENT OFCONSTRUCTION. THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE PROFESSIONAL OF RECORD AND BOHLER, IN WRITING, IF ANY CONFLICTS,DISCREPANCIES, OR AMBIGUITIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION. NO EXTRA COMPENSATION WILL BE PAID TO THECONTRACTOR FOR WORK WHICH HAS TO BE RE-DONE OR REPAIRED DUE TO DIMENSIONS, MEASUREMENTS OR GRADES SHOWN INCORRECTLY ONTHESE PLANS PRIOR TO BOTH (A) THE CONTRACTOR GIVING THE PROFESSIONAL OF RECORD AND BOHLER WRITTEN NOTIFICATION OF SAME AND (B)PROFESSIONAL OF RECORD AND BOHLER, THEREAFTER, PROVIDING THE CONTRACTOR WITH WRITTEN AUTHORIZATION TO PROCEED WITH SUCHADDITIONAL WORK.9.THE CONTRACTOR MUST VERIFY ALL DIMENSIONS AND MEASUREMENTS INCLUDED ON DESIGN DOCUMENTS HEREIN AND MUST NOT SCALE OFF THEDRAWINGS DUE TO POTENTIAL PRINTING INACCURACIES. ALL DIMENSIONS AND MEASUREMENTS ARE TO BE CHECKED AND CONFIRMED BY THEGENERAL CONTRACTOR PRIOR TO PREPARATION OF SHOP DRAWINGS, FABRICATION/ORDERING OF PARTS AND MATERIALS AND COMMENCEMENTOF SITE WORK. SITE PLAN DRAWINGS ARE NOT INTENDED AS SURVEY DOCUMENTS. DIMENSIONS SUPERSEDE GRAPHICAL REPRESENTATIONS. THECONTRACTOR MUST MAKE CONTRACTOR'S OWN MEASUREMENTS FOR LAYOUT OF IMPROVEMENTS.10.THE OWNER AND CONTRACTOR MUST BE FAMILIAR WITH AND RESPONSIBLE FOR THE PROCUREMENT OF ANY AND ALL CERTIFICATIONS REQUIREDFOR THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY. 11.WHEN INCLUDED AS ONE OF THE REFERENCED DOCUMENTS, THE GEOTECHNICAL REPORT, SPECIFICATIONS AND RECOMMENDATIONS SET FORTHTHEREIN ARE A PART OF THE REQUIRED CONSTRUCTION DOCUMENTS AND, IN CASE OF CONFLICT, DISCREPANCY OR AMBIGUITY, THE MORESTRINGENT REQUIREMENTS AND/OR RECOMMENDATIONS CONTAINED IN: (A) THE PLANS; AND (B) THE GEOTECHNICAL REPORT ANDRECOMMENDATIONS, MUST TAKE PRECEDENCE UNLESS SPECIFICALLY NOTED OTHERWISE ON THE PLANS. THE CONTRACTOR MUST NOTIFY THEPROFESSIONAL OF RECORD AND BOHLER, IN WRITING, OF ANY SUCH CONFLICT, DISCREPANCY OR AMBIGUITY BETWEEN THE GEOTECHNICALREPORT AND PLANS AND SPECIFICATIONS, PRIOR TO PROCEEDING WITH ANY FURTHER WORK. IF A GEOTECHNICAL REPORT WAS NOT CREATED,THEN THE CONTRACTOR MUST FOLLOW AND COMPLY WITH ALL OF THE REQUIREMENTS OF ANY AND ALL MUNICIPAL, COUNTY, STATE, AND FEDERALLAWS AND APPLICABLE SPECIFICATIONS WHICH HAVE JURISDICTION OVER THIS PROJECT.12.THE PROFESSIONAL OF RECORD AND BOHLER ARE NEITHER LIABLE NOR RESPONSIBLE FOR ANY SUBSURFACE CONDITIONS AND FURTHER, HAS NOLIABILITY FOR ANY HAZARDOUS MATERIALS, HAZARDOUS SUBSTANCES, OR POLLUTANTS ON, ABOUT OR UNDER THE PROPERTY. 13.THE CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING WHEN AND WHERE SHORING IS REQUIRED AND FOR INSTALLING ALL SHORING REQUIREDDURING EXCAVATION (TO BE PERFORMED IN ACCORDANCE WITH CURRENT OSHA STANDARDS) AND ANY ADDITIONAL PRECAUTIONS TO BE TAKEN TOASSURE THE STABILITY OF ADJACENT, NEARBY AND CONTIGUOUS STRUCTURES AND PROPERTIES. ALL OF THIS WORK IS TO BE PERFORMED ATCONTRACTOR'S SOLE COST AND EXPENSE.14.THE CONTRACTOR MUST EXERCISE EXTREME CAUTION WHEN PERFORMING ANY WORK ACTIVITIES ADJACENT TO PAVEMENT, STRUCTURES, ETC.WHICH ARE TO REMAIN EITHER FOR AN INITIAL PHASE OF THE PROJECT OR AS PART OF THE FINAL CONDITION. THE CONTRACTOR IS RESPONSIBLEFOR TAKING ALL APPROPRIATE MEASURES REQUIRED TO ENSURE THE STRUCTURAL STABILITY OF SIDEWALKS AND PAVEMENT, UTILITIES,BUILDINGS, AND INFRASTRUCTURE WHICH ARE TO REMAIN, AND TO PROVIDE A SAFE WORK AREA FOR THIRD PARTIES, PEDESTRIANS AND ANYONEINVOLVED WITH THE PROJECT. 15.DEBRIS MUST NOT BE BURIED ON THE SUBJECT SITE. ALL DEMOLITION AND CONSTRUCTION WASTES, UNSUITABLE EXCAVATED MATERIAL, EXCESSSOIL AND DEBRIS (SOLID WASTE) MUST BE DISPOSED OF IN ACCORDANCE WITH THE REQUIREMENTS OF ANY AND ALL MUNICIPAL, COUNTY, STATE,AND FEDERAL LAWS AND APPLICABLE CODES WHICH HAVE JURISDICTION OVER THIS PROJECT OR OVER THE CONTRACTOR. 16.IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO MAINTAIN RECORDS TO DEMONSTRATE PROPER AND FULLY COMPLIANT DISPOSAL ACTIVITIES,TO BE PROMPTLY PROVIDED TO THE OWNER UPON REQUEST. 17.THE CONTRACTOR MUST REPAIR, AT CONTRACTOR'S SOLE COST, ALL DAMAGE DONE TO ANY NEW OR EXISTING CONSTRUCTION OR PROPERTYDURING THE COURSE OF CONSTRUCTION, INCLUDING BUT NOT LIMITED TO DRAINAGE, UTILITIES, PAVEMENT, STRIPING, CURB, ETC. AND MUST BEARALL COSTS ASSOCIATED WITH SAME TO INCLUDE, BUT NOT BE LIMITED TO, REDESIGN, RE-SURVEY, RE-PERMITTING AND CONSTRUCTION. THECONTRACTOR IS RESPONSIBLE FOR AND MUST REPLACE ALL SIGNAL INTERCONNECTION CABLE, WIRING CONDUITS, AND ANY UNDERGROUNDACCESSORY EQUIPMENT DAMAGED DURING CONSTRUCTION AND MUST BEAR ALL COSTS ASSOCIATED WITH SAME. THE REPAIR OF ANY SUCH NEWOR EXISTING CONSTRUCTION OR PROPERTY MUST RESTORE SUCH CONSTRUCTION OR PROPERTY TO A CONDITION EQUIVALENT TO OR BETTERTHAN THE CONDITIONS PRIOR TO COMMENCEMENT OF THE CONSTRUCTION, AND IN CONFORMANCE WITH APPLICABLE CODES, LAWS, RULES,REGULATIONS, STATUTORY REQUIREMENTS AND STATUTES. THE CONTRACTOR MUST BEAR ALL COSTS ASSOCIATED WITH SAME. THE CONTRACTORMUST, PROMPTLY, DOCUMENT ALL EXISTING DAMAGE AND NOTIFY, IN WRITING, THE OWNER AND THE CONSTRUCTION MANAGER PRIOR TO THESTART OF CONSTRUCTION.18.THE PROFESSIONAL OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR AND HAVE NO CONTRACTUAL, LEGAL OR OTHER RESPONSIBILITIES FORJOB SITE SAFETY JOB SITE SUPERVISION, OR ANYTHING RELATED TO SAME. THE PROFESSIONAL OF RECORD AND BOHLER HAVE NOT BEENRETAINED TO PERFORM OR TO BE RESPONSIBLE FOR JOB SITE SAFETY, SAME BEING WHOLLY OUTSIDE OF THE PROFESSIONAL OF RECORD'S ANDBOHLER SERVICES AS RELATED TO THE PROJECT. THE PROFESSIONAL OF RECORD AND BOHLER ARE NOT RESPONSIBLE TO IDENTIFY OR REPORTANY JOB SITE SAFETY ISSUES OR ANY JOB SITE CONDITIONS, AT ANY TIME.19.THE CONTRACTOR MUST IMMEDIATELY IDENTIFY IN WRITING, TO THE PROFESSIONAL OF RECORD AND BOHLER, ANY DISCREPANCIES THAT MAY ORCOULD AFFECT THE PUBLIC SAFETY, HEALTH OR GENERAL WELFARE, OR PROJECT COST. IF THE CONTRACTOR PROCEEDS WITH CONSTRUCTIONWITHOUT PROVIDING PROPER WRITTEN NOTIFICATION AS DESCRIBED ABOVE, IT WILL BE AT THE CONTRACTOR'S OWN RISK AND, FURTHER, THECONTRACTOR MUST INDEMNIFY, DEFEND AND HOLD HARMLESS THE PROFESSIONAL OF RECORD AND BOHLER FOR ANY AND ALL DAMAGES, COSTS,INJURIES, ATTORNEY'S FEES AND THE LIKE WHICH RESULT FROM OR ARE IN ANY WAY RELATED TO SAME INCLUDING, BUT NOT LIMITED TO, ANYTHIRD PARTY AND FIRST PARTY CLAIMS. 20.THE PROFESSIONAL OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR ANY INJURY OR DAMAGES RESULTING FROM THE CONTRACTOR'SFAILURE TO BUILD OR CONSTRUCT IN STRICT ACCORDANCE WITH THE APPROVED PLANS, AND CURRENT CODES, RULES, STATUTES AND THE LIKE. IFTHE CONTRACTOR AND/OR OWNER FAIL TO BUILD OR CONSTRUCT IN STRICT ACCORDANCE WITH APPROVED PLANS, RULES, STATUTES, CODES ANDTHE LIKE, THE CONTRACTOR AND/OR OWNER AGREE TO AND MUST JOINTLY, INDEPENDENTLY, SEPARATELY, AND SEVERALLY INDEMNIFY AND HOLDTHE PROFESSIONAL OF RECORD AND BOHLER HARMLESS FOR AND FROM ALL INJURIES, CLAIMS AND DAMAGES THAT THE PROFESSIONAL OFRECORD AND BOHLER SUFFER AND ANY AND ALL COSTS THAT THE PROFESSIONAL OF RECORD AND BOHLER INCUR AS RELATED TO SAME.21.ALL CONTRACTORS MUST CARRY AT LEAST THE MINIMUM AMOUNT OF THE SPECIFIED AND COMMERCIALLY REASONABLE STATUTORY WORKER'SCOMPENSATION INSURANCE, EMPLOYER'S LIABILITY INSURANCE AND COMMERCIAL GENERAL LIABILITY INSURANCE (CGL) INCLUDING ALSO ALLUMBRELLA COVERAGES. ALL CONTRACTORS MUST HAVE THEIR CGL POLICIES ENDORSED TO NAME BOHLER , AND ITS PAST, PRESENT AND FUTUREOWNERS, OFFICERS, DIRECTORS, PARTNERS, SHAREHOLDERS, MEMBERS, PRINCIPALS, COMMISSIONERS, AGENTS, SERVANTS, EMPLOYEES,AFFILIATES, SUBSIDIARIES, AND RELATED ENTITIES, AND ITS SUBCONTRACTORS AND SUBCONSULTANTS AS ADDITIONAL NAMED INSUREDS AND TOPROVIDE CONTRACTUAL LIABILITY COVERAGE SUFFICIENT TO INSURE (DEFEND, IF APPLICABLE) AND HOLD HARMLESS AND INDEMNITY OBLIGATIONSASSUMED AND AGREED TO BY THE CONTRACTOR HEREIN. ALL CONTRACTORS MUST FURNISH BOHLER WITH CERTIFICATIONS OF INSURANCE ORCERTIFICATES OF INSURANCE AS EVIDENCE OF THE REQUIRED INSURANCE COVERAGES PRIOR TO COMMENCING ANY WORK AND UPON RENEWALOF EACH POLICY DURING THE ENTIRE PERIOD OF CONSTRUCTION AND FOR TWO YEARS AFTER THE COMPLETION OF CONSTRUCTION AND AFTERALL PERMITS ARE ISSUED, WHICHEVER DATE IS LATER. IN ADDITION, ALL CONTRACTORS AGREE THAT THEY WILL, TO THE FULLEST EXTENTPERMITTED UNDER THE LAW, INDEMNIFY, DEFEND AND HOLD HARMLESS BOHLER AND ITS PAST, PRESENT AND FUTURE OWNERS, OFFICERS,DIRECTORS, PARTNERS, SHAREHOLDERS, MEMBERS, PRINCIPALS, COMMISSIONERS, AGENTS, SERVANTS, EMPLOYEES, AFFILIATES, SUBSIDIARIES,AND RELATED ENTITIES, AND ITS SUBCONTRACTORS AND SUBCONSULTANTS FROM AND AGAINST ANY DAMAGES, INJURIES, CLAIMS, ACTIONS,PENALTIES, EXPENSES, PUNITIVE DAMAGES, TORT DAMAGES, STATUTORY CLAIMS, STATUTORY CAUSES OF ACTION, LOSSES, CAUSES OF ACTION,LIABILITIES OR COSTS, INCLUDING, BUT NOT LIMITED TO, REASONABLE ATTORNEYS' FEES AND DEFENSE COSTS, ARISING OUT OF OR IN ANY WAYCONNECTED WITH OR TO THE PROJECT, INCLUDING ALL CLAIMS BY EMPLOYEES OF THE CONTRACTOR(S), ALL CLAIMS BY THIRD PARTIES AND ALLCLAIMS RELATED TO THE PROJECT. THE CONTRACTOR MUST NOTIFY THE PROFESSIONAL OF RECORD, IN WRITING, AT LEAST THIRTY (30) DAYSPRIOR TO ANY TERMINATION, SUSPENSION OR CHANGE OF ITS INSURANCE HEREUNDER.22.THE PROFESSIONAL OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR CONSTRUCTION METHODS, MEANS, TECHNIQUES OR PROCEDURES,GENERALLY OR FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES OR PROCEDURES FOR COMPLETION OF THE WORK DEPICTED BOTH ONTHESE PLANS, AND FOR ANY CONFLICTS IN SCOPE AND REVISIONS THAT RESULT FROM SAME. THE CONTRACTOR IS FULLY AND SOLELYRESPONSIBLE FOR DETERMINING THE MEANS AND METHODS FOR COMPLETION OF THE WORK, PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 23.NEITHER THE PROFESSIONAL ACTIVITIES OF BOHLER, NOR THE PRESENCE OF BOHLER AND/OR ITS PAST, PRESENT AND FUTURE OWNERS,OFFICERS, DIRECTORS, PARTNERS, SHAREHOLDERS, MEMBERS, PRINCIPALS, COMMISSIONERS, AGENTS, SERVANTS, EMPLOYEES, AFFILIATES,SUBSIDIARIES, AND RELATED ENTITIES, AND ITS SUBCONTRACTORS AND SUBCONSULTANTS AT A CONSTRUCTION/PROJECT SITE (HEREIN “BOHLERPARTIES”), RELIEVES OR WILL RELIEVE THE CONTRACTOR OF AND FROM CONSTRUCTION MEANS, METHODS, SEQUENCE, TECHNIQUES ORPROCEDURES NECESSARY FOR PERFORMING, OVERSEEING, SUPERINTENDING AND COORDINATING THE WORK IN ACCORDANCE WITH THECONTRACT DOCUMENTS AND COMPLIANCE WITH ALL HEALTH AND SAFETY PRECAUTIONS REQUIRED BY ANY REGULATORY AGENCIES WITHJURISDICTION OVER THE PROJECT AND/OR PROPERTY. BOHLER PARTIES HAVE NO AUTHORITY TO EXERCISE ANY CONTROL OVER (OR ANYRESPONSIBILITY FOR) ANY CONSTRUCTION, THE CONTRACTOR OR ITS EMPLOYEES RELATING TO THEIR WORK AND ANY AND ALL HEALTH ANDSAFETY PROGRAMS OR PROCEDURES. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR JOB SITE SAFETY. THE CONTRACTOR MUST INDEMNIFY,DEFEND, PROTECT AND HOLD HARMLESS BOHLER PARTIES FOR AND FROM ANY LIABILITY TO BOHLER PARTIES RESULTING FROM THECONTRACTOR'S WORK, SERVICES AND/OR VIOLATIONS OF THIS NOTE, THESE NOTES OR ANY NOTES IN THE PLAN SET AND, FURTHER, THECONTRACTOR MUST NAME BOHLER AS AN ADDITIONAL INSURED UNDER THE GENERAL CONTRACTOR'S POLICIES OF GENERAL LIABILITY INSURANCEAS DESCRIBED ABOVE.24.WHEN IT IS CLEARLY AND SPECIFICALLY WITHIN BOHLER'S SCOPE OF SERVICES CONTRACT WITH THE OWNER/DEVELOPER, BOHLER WILL REVIEW ORTAKE OTHER APPROPRIATE ACTION ON THE CONTRACTOR SUBMITTALS, SUCH AS SHOP DRAWINGS, PRODUCT DATA, SAMPLES, AND OTHER DATA,WHICH THE CONTRACTOR IS REQUIRED TO SUBMIT, BUT ONLY FOR THE LIMITED PURPOSE OF EVALUATING CONFORMANCE WITH THE DESIGNINTENT AND THE INFORMATION SHOWN IN THE CONSTRUCTION CONTRACT DOCUMENTS. CONSTRUCTION MEANS AND METHODS AND/ORTECHNIQUES OR PROCEDURES, COORDINATION OF THE WORK WITH OTHER TRADES, AND CONSTRUCTION SAFETY PRECAUTIONS ARE THE SOLERESPONSIBILITY OF THE CONTRACTOR AND BOHLER HAS NO RESPONSIBILITY OR LIABILITY FOR SAME. BOHLER WILL PERFORM ITS SHOP DRAWINGREVIEW WITH REASONABLE PROMPTNESS, AS CONDITIONS PERMIT. ANY DOCUMENT, DOCUMENTING BOHLER'S REVIEW OF A SPECIFIC ITEM ORLIMITED SCOPE, MUST NOT INDICATE THAT BOHLER HAS REVIEWED THE ENTIRE ASSEMBLY OF WHICH THE ITEM IS A COMPONENT. BOHLER IS NOTRESPONSIBLE FOR ANY DEVIATIONS FROM THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR MUST, IN WRITING, PROMPTLY AND IMMEDIATELYBRING ANY DEVIATIONS FROM THE CONSTRUCTION DOCUMENTS TO BOHLER'S ATTENTION. BOHLER IS NOT REQUIRED TO REVIEW PARTIALSUBMISSIONS OR THOSE FOR WHICH SUBMISSIONS OF CORRELATED ITEMS HAVE NOT BEEN RECEIVED. 25.IF THE CONTRACTOR DEVIATES FROM THESE PLANS AND/OR SPECIFICATIONS, INCLUDING THE NOTES CONTAINED HEREIN, WITHOUT FIRSTOBTAINING THE PRIOR WRITTEN AUTHORIZATION OF THE PROFESSIONAL OF RECORD AND BOHLER FOR ALL DEVIATIONS WITHIN THE PROFESSIONALOF RECORD'S AND BOHLER SCOPE, THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE PAYMENT OF ALL COSTS INCURRED IN CORRECTING ANYWORK PERFORMED WHICH DEVIATES FROM THE PLANS, ALL FINES AND/OR PENALTIES ASSESSED WITH RESPECT THERETO AND ALLCOMPENSATORY OR PUNITIVE DAMAGES RESULTING THEREFROM AND, FURTHER, MUST DEFEND, INDEMNIFY, PROTECT, AND HOLD HARMLESS THEPROFESSIONAL OF RECORD AND BOHLER PARTIES TO THE FULLEST EXTENT PERMITTED UNDER THE LAW, FOR AND FROM ALL FEES, ATTORNEYS'FEES, DAMAGES, COSTS, JUDGMENTS, CLAIMS, INJURIES, PENALTIES AND THE LIKE RELATED TO SAME. 26.THE CONTRACTOR IS RESPONSIBLE FOR A MAINTAINING AND PROTECTING THE TRAFFIC CONTROL PLAN AND ELEMENTS IN ACCORDANCE WITHFEDERAL, STATE, AND LOCAL REQUIREMENTS, FOR ALL WORK THAT AFFECTS PUBLIC TRAVEL EITHER IN THE RIGHT OF WAY OR ON SITE. THE COSTFOR THIS ITEM MUST BE INCLUDED IN THE CONTRACTOR'S PRICE AND IS THE CONTRACTOR'S SOLE RESPONSIBILITY. 27.OWNER MUST MAINTAIN AND PRESERVE ALL PHYSICAL SITE FEATURES AND DESIGN FEATURES DEPICTED ON THE PLANS AND RELATED DOCUMENTSIN STRICT ACCORDANCE WITH THE APPROVED PLAN(S) AND DESIGN; AND, FURTHER, THE PROFESSIONAL OF RECORD AND BOHLER ARE NOTRESPONSIBLE FOR ANY FAILURE TO SO MAINTAIN OR PRESERVE SITE AND/OR DESIGN FEATURES. IF OWNER FAILS TO MAINTAIN AND/OR PRESERVEALL PHYSICAL SITE FEATURES AND/OR DESIGN FEATURES DEPICTED ON THE PLANS AND RELATED DOCUMENTS, OWNER AGREES TO INDEMNIFYAND HOLD THE PROFESSIONAL OF RECORD AND BOHLER PARTIES, HARMLESS FOR ALL INJURIES, DAMAGES AND COSTS THAT THE PROFESSIONALOF RECORD AND BOHLER INCUR AS A RESULT OF SAID FAILURE OR FAILURE TO PRESERVE. 28.THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ENSURING THAT ALL CONSTRUCTION ACTIVITIES AND MATERIALS COMPLY WITH AND CONFORM TOAPPLICABLE FEDERAL, STATE AND LOCAL RULES AND REGULATIONS, LAWS, ORDINANCES, AND CODES, AND ALL APPLICABLE REQUIREMENTS OFTHE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.) AS AMENDED, AND ANY MODIFICATIONS, AMENDMENTS OR REVISIONSTO SAME.29.THE CONTRACTOR MUST STRICTLY COMPLY WITH THE LATEST AND CURRENT OSHA STANDARDS AND REGULATIONS, AND/OR ANY OTHER AGENCYWITH JURISDICTION OVER EXCAVATION AND TRENCHING PROCEDURES. THE PROFESSIONAL OF RECORD AND BOHLER HAS NO RESPONSIBILITY FOROR AS RELATED TO EXCAVATION AND TRENCHING PROCEDURES AND WORK. 30.THE CONTRACTOR AND THE OWNER MUST INSTALL ALL ELEMENTS AND COMPONENTS IN STRICT COMPLIANCE WITH AND IN ACCORDANCE WITHMANUFACTURER'S STANDARDS AND RECOMMENDED INSTALLATION CRITERIA AND SPECIFICATIONS. IF THE CONTRACTOR AND/OR OWNER FAIL TODO SO, THEY AGREE TO JOINTLY, INDEPENDENTLY, SEPARATELY, COLLECTIVELY, AND SEVERALLY INDEMNIFY, DEFEND, PROTECT AND HOLD THEPROFESSIONAL OF RECORD AND BOHLER PARTIES HARMLESS FOR ALL INJURIES AND DAMAGES THAT PROFESSIONAL OF RECORD SUFFERS ANDCOSTS THAT THE PROFESSIONAL OF RECORD INCURS AS A RESULT OF SAID FAILURE.31.THE CONTRACTOR IS RESPONSIBLE TO MAINTAIN AN ON-SITE STORMWATER POLLUTION PREVENTION PLAN (SWPPP) IN COMPLIANCE WITH THEENVIRONMENTAL PROTECTION AGENCY (EPA) REQUIREMENTS OR LOCAL GOVERNING AGENCY FOR SITES WHERE ONE (1) ACRE OR MORE ISDISTURBED BY CONSTRUCTION ACTIVITIES (UNLESS THE LOCAL JURISDICTION REQUIRES A DIFFERENT THRESHOLD). THE CONTRACTOR MUSTENSURE THAT ALL ACTIVITIES, INCLUDING THOSE OF ALL SUBCONTRACTORS, ARE IN COMPLIANCE WITH THE SWPPP, INCLUDING BUT NOT LIMITEDTO LOGGING ACTIVITIES (MINIMUM ONCE PER WEEK AND AFTER RAINFALL EVENTS) AND CORRECTIVE MEASURES, AS APPROPRIATE AND FURTHER,THE CONTRACTOR IS SOLELY AND COMPLETELY RESPONSIBLE FOR FAILING TO DO SO. 32.AS CONTAINED IN THESE DRAWINGS AND ASSOCIATED DOCUMENTS PREPARED BY THE PROFESSIONAL OF RECORD AND BOHLER, THE USE OF THEWORDS 'CERTIFY' OR 'CERTIFICATION' CONSTITUTE(S) AN EXPRESSION ONLY OF PROFESSIONAL OPINION REGARDING THE INFORMATION WHICH ISTHE SUBJECT OF THE PROFESSIONAL OF RECORD'S AND BOHLER KNOWLEDGE OR BELIEF AND IN ACCORDANCE WITH COMMON AND ACCEPTEDPROCEDURE CONSISTENT WITH THE APPLICABLE STANDARDS OF PRACTICE, AND DOES NOT CONSTITUTE A WARRANTY OR GUARANTEE OF ANYNATURE OR TYPE, EITHER EXPRESSED OR IMPLIED, UNDER ANY CIRCUMSTANCES. SOUTH BROADWAYU.S. ROUTE 9 LANDS N/F OFEFF-JAY REALTY, LLCBK. 1676, PG. 73SECTION 178.00 BLOCK 2 LOT 17.11LANDS N/F OF3368 S BROADWAY HOTEL LLCINSTR. 2022-31739SECTION 178.00 BLOCK 2 LOT 16LANDS N/F OFF.W. OF SARATOGA, INC.BK. 1099, PG. 477SECTION 178.00 BLOCK 2 LOT 17.2LANDS N/F OFF.W. OF SARATOGA, INC.BK. 1078, PG. 336SECTION 178.00 BLOCK 2 LOT 11.1LANDS N/F OFF.W. OF SARATOGA, INC.BK. 1498, PG. 47SECTION 178.00 BLOCK 2 LOT 23LANDS N/F OF3402 ROUTE 9, LLCINSTR. 2013-43252SECTION 178.00 BLOCK 2 LOT 22N 12°46'59" E 501.66'S 85°46'00" E 610.83'N 10°13'59" E 7 3 . 9 6 'N 86°12'05" E 170.93'N 86°41'18" E 107.94'S 11°54'18" W 6 1 7 . 3 5 'N 85°30'00" W 887.00'WETLAND "A"AREA=0.53 ACRESAREA: 10.682 ACRESEXIST CULVERT ANDTWO (2) FES(TBR)(TBR)EXIST 24" CULVERT AND TWO (2) FES(TO BE REMOVED AND REPLACED) (SEESHEET C-401 FOR DETAILS)(TBR)(TBR)(TBR)(TBR)(TBR)(TBR)(TBR)(TBR)(TBR)(TBR)(TBR)(TBR)(TBR)(TBR)(TBR)(TBR)(TBR)(TBR)(TBR)EXIST CULVERT AND TWO (2) FES (TBR). AFTER EXIST. CULVERTIS REMOVED, THE EXIST. SWALE SHALL BE RESHAPED ANDPOSITIVE DRAINAGE FLOW SHALL BE MAINTAINED. (TYP)(TO REMAIN)GC TO COORDINATE WITH UTILITYCOMPANY TO ENSURE OVERHEAD LINESARE A MINIMUM OF 14' ABOVE FINISHEDGRADE.(TBR)PROP TREELINE (TYP)(TBR)EXIST. TREELINE (TBR)LIMIT OF TREELINE REMOVALLIMIT OF TREELINE REMOVALLIMIT OF TREELINE REMOVALPROP TREELINE (TYP)PROP TREELINE (TYP)EXIST. TREELINE (TBR)EXIST. TREELINE (TBR)EXIST. TREELINE (TBR)AREA TO BE CLEAREDAND GRUBBED (TYP)- TOPSOIL TO BESTOCKPILED ON SITEEXIST PAVEMENTSTRIPING (TBR) (TYP)LIMIT OF PAVEMENTREMOVALLIMIT OF PAVEMENTREMOVALEXIST. VEGETATION (TBR)GC TO COORDINATE WITH UTILITY COMPANY TO ENSUREOVERHEAD LINES ARE A MINIMUM OF 14' ABOVE FINISHEDGRADE. GC TO CONFIRM WIRE HEIGHTS AT PROP. DRIVEWAYSAND NOTIFY ENGINEER OF RECORD PRIOR TO CONSTRUCTION.EXIST WATER AND GAS MAINS TO REMAIN AND BEPROTECTED THROUGHOUT CONSTRUCTION. GC TOCONFIRM LOCATION OF MAINS AND NOTIFY ENGINEEROF RECORD OF ANY DISCREPANCIESEXIST ACCESS DRIVE (TBR)EXIST ACCESS DRIVE (TBR)EXIST CURB (TBR)EXIST TREELINE (TO REMAIN) (TYP)EXIST TREELINE (TO REMAIN) (TYP)EXIST TREELINE (TO REMAIN) (TYP)EXIST TREELINE (TO REMAIN) (TYP)EXIST SANITARY LINES TOREMAIN AND BE PROTECTEDTHROUGHOUT CONSTRUCTION.GC TO LOCATE EXIST. MAIN ANDCONFIRM DEPTH PRIOR TOCONSTRUCTIONPROP SAWCUT LINE (TYP)PROP SAWCUT LINE (TYP)EXIST EDGE OFPAVEMENT (TBR) (TYP)PROP LIMIT OFDISTURBANCE (TYP)PROP LIMIT OFDISTURBANCE (TYP)PROP LIMIT OFDISTURBANCE (TYP)PROP LIMIT OFDISTURBANCE (TYP)PROP LIMIT OFDISTURBANCE (TYP)LIMIT OF TREELINE REMOVALLIMIT OF TREELINE REMOVALEXIST TREELINE (TO REMAIN) (TYP)AREA TO BE CLEAREDAND GRUBBED (TYP)- TOPSOIL TO BESTOCKPILED ON SITEAREA TO BE CLEAREDAND GRUBBED (TYP)- TOPSOIL TO BESTOCKPILED ON SITEEXIST EDGE OFPAVEMENT (TBR) (TYP)LIMIT OF PAVEMENTREMOVALPROP SAWCUT LINE (TYP)EXIST UTILITY POLE ANDOVERHEAD WIRES TO REMAINAND BE PROTECTEDTHROUGHOUT CONSTRUCTIONEXIST CONC. SIDEWALK(TO REMAIN)EXIST. HYDRANT AND SERVICE TOREMAIN AND BE PROTECTEDTHROUGHOUT CONSTRUCTIONLIMIT OF CHAIN LINKFENCE REMOVALEXIST CONC. SIDEWALK(TO REMAIN)EXIST UTILITY POLE AND OVERHEAD WIRES TO REMAIN ANDBE PROTECTED THROUGHOUT CONSTRUCTION. GC TOCONFIRM WIRE HEIGHTS AT PROP. DRIVEWAYS AND NOTIFYENGINEER OF RECORD PRIOR TO CONSTRUCTION.EXIST. WATER LATERAL ANDWATER VALVE TO REMAIN ANDBE PROTECTED THROUGHOUTCONSTRUCTIONEXIST UTILITY POLE TO REMAINAND BE PROTECTEDTHROUGHOUT CONSTRUCTIONEXIST UTILITY POLE TO REMAINAND BE PROTECTEDTHROUGHOUT CONSTRUCTIONEXIST WETLAND AREA TO REMAINAND BE PROTECTED THROUGHOUTCONSTRUCTION. GC TO INSTALLCONSTRUCTION FENCE ANDDOUBLE ROW OF SILT FENCE TOPROTECT WETLANDS PRIOR TOTHE START OF CONSTRUCTIONEXIST WETLAND AREA TO REMAIN AND BEPROTECTED THROUGHOUT CONSTRUCTION. GCTO INSTALL CONSTRUCTION FENCE AND DOUBLEROW OF SILT FENCE TO PROTECT WETLANDSPRIOR TO THE START OF CONSTRUCTION(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO RE M A I N )(TO REMAIN)=ONE: GC-R(GATEWAY COMMERCIAL RURAL)USE: HOMEWOOD SUITES=ONE: GC-R(GATEWAY COMMERCIAL RURAL)USE: SARATOGA HONDA=ONE: GC-R(GATEWAY COMMERCIAL RURAL)USE: FOUR WINDS OF SARATOGA=ONE: GC-R(GATEWAY COMMERCIAL RURAL)USE: FOUR WINDS OF SARATOGA=ONE: GC-R(GATEWAY COMMERCIAL RURAL)USE: FOUR WINDS OF SARATOGA=ONE: GC-R(GATEWAY COMMERCIAL RURAL)USE: VACANTLIMIT OF TREELINEREMOVALLIMIT OF FENCE REMOVALPORTION OF EXIST. FENCE (TO REMAIN)PROP LIMIT OFDISTURBANCE (TYP)GC TO CONFIRM EXIST. UTILITYPOLES ARE ABANDONED PRIOR TOCONSTRUCTION AND SHALLNOTIFY ENGINEER OF RECORD OFANY DISCREPANCIES (TYP OF 7)PROP LIMIT OFDISTURBANCE (TYP)LIMIT OF EXIST. VEGETATION REMOVALPROP. VEGETATION LINEEXIST. VEGETATION (TO REMAIN)EXIST WATER AND GASMAINS TO REMAIN AND BEPROTECTED THROUGHOUTCONSTRUCTIONAFTER EXIST. DRIVEWAYS AND CULVERTS AREREMOVED, THE EXIST. SWALE SHALL BERESHAPED AND POSITIVE DRAINAGE FLOWSHALL BE MAINTAINED. (TYP)AFTER EXIST. DRIVEWAYS AND CULVERTS AREREMOVED, THE EXIST. SWALE SHALL BERESHAPED AND POSITIVE DRAINAGE FLOWSHALL BE MAINTAINED. (TYP)REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY12345678REVISION 8 -01/19/2024CLIENT COMMENTSSGSW02/02/2024CITY COMMENTSSGVR03/04/2024CITY COMMENTSSGSW03/20/2024CITY COMMENTSSGVR04/15/2024CITY AND TDECOMMENTSAKDSRW05/03/2024PRELIMINARY ISSUEFOR CONSTRUCTIONAKDSRW06/07/2024DOT AND SCSDCOMMENTSAKDSRW06/14/2024ADDENDUM 1AKDSRW06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORP:\2023\NYB230191.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\NYB230191.00-SPPD-0A----->LAYOUT: C-201 DEMOAD THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191SAG/AKDSRW11/30/2023NYB230191.00-SPPD-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK 2 - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comREFER TO GENERAL NOTES SHEET FORDEMOLITION NOTESTHIS PLAN TO BE UTILIZED FORDEMOLITION/ REMOVALPURPOSES ONLY1"=40'040102040DEMOLITIONPLANC-201WESANY WORK PROPOSED WITHIN THENYSDOT ROW WILL REQUIRE A PERMITFROM NYSDOT. GC TO COORDINATE ALLPERMIT REQUIREMENTS WITH NYSDOTPRIOR TO CONSTRUCTION. SOUTH BROADWAYU.S. ROUTE 9LANDS N/F OF EFF-JAY REALTY, LLC BK. 1676, PG. 73 SECTION 178.00 BLOCK 2 LOT 17.11 LANDS N/F OF 3368 S BROADWAY HOTEL LLC INSTR. 2022-31739 SECTION 178.00 BLOCK 2 LOT 16 LANDS N/F OF F.W. OF SARATOGA, INC. BK. 1099, PG. 477 SECTION 178.00 BLOCK 2 LOT 17.2 LANDS N/F OF F.W. OF SARATOGA, INC. BK. 1078, PG. 336 SECTION 178.00 BLOCK 2 LOT 11.1 LANDS N/F OF F.W. OF SARATOGA, INC. BK. 1498, PG. 47 SECTION 178.00 BLOCK 2 LOT 23 LANDS N/F OF 3402 ROUTE 9, LLC INSTR. 2013-43252 SECTION 178.00 BLOCK 2 LOT 22 N 12°46'59" E 501.66'S 85°46'00" E 610.83'N 10°13'59" E 73.96'N 86°12'05" E 1 7 0 . 9 3 ' N 86°41'18" E 1 0 7 . 9 4 'S 11°54'18" W 617.35'N 85°30'00" W 887.00' WETLAND "A" AREA=0.53 ACRES T LBLBLB LB LB LB LB LB LBBSBS BSBST T T BSBST T TT S S 10 10 10 10 10 10 10 10 9 10 6 9 7 810 10 6 10 10 10 10 10 10 10 10 101010109 10 8 7 57.6'20' SIDE YARD SETBACK 114.6'100.1'215.5'24.0'(TYP)24.0'(TYP)24.0'(TYP)18.0'(TYP)167.2'18.0'(TYP)18.0'(TYP)18.0'(TYP)18.0'(TYP)18' (TYP) 24' (TYP) 14' 9' (TYP) 24'18'5.0'20'16'18'16'9' (TYP)39.4'PROP. BOCCE COURT. REFER TO SHEET L-601 441.1'84'5.0'10' 8' (TYP) 8' (TYP)16'9' (TYP)339' +/-(DISTANCE TO NEAREST DRIVEWAY 33'R 33'R 33'R 33'R 8.0'8'62'23.8'33.2'4.8'4.3' 10' PROP. SWALE 80'40.3'33' 20'R 20'R 3'R 163'R 179'R 2'R 50'R 30'R 20'R 3'R 3'R 3'R 10'R 3'R 20'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 10'R 44'R 60'R 10'R 3'R 20'R 3'R 10'R 3'R 3'R 3'R 20'R 20'R 3'R 14'R 41'R 49'R 198'R 189'R 3'R 3'R 3'R 3'R 3'R 3'R 7'R 7'R 41'R 2'R 30'R 2'R 2'R 103'R 146'R 72'R 80'R 119'R 111'R 111'R 119'R 22'R 30'R 5'R 7'R 10'R 5'R 10'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 15.5'5.0'5.6'25.9'74.0'48.0'36.0'35.9'48.0'74.0'61.5'61.6'80.2'25.0' 122.0'61.5'9' (TYP)9.0'(TYP)9. 0 ' (T Y P )23.2'9.0 ' (TYP ) 14.4'16.0'(TO REMAIN) (TO REMAIN) (TO REMAIN) (TO REMAIN) (TO REMAIN)(TO REMAIN)(TO REMAIN) =ONE: GC-R (GATEWAY COMMERCIAL RURAL) USE: HOMEWOOD SUITES =ONE: GC-R (GATEWAY COMMERCIAL RURAL) USE: SARATOGA HONDA =ONE: GC-R (GATEWAY COMMERCIAL RURAL) USE: FOUR WINDS OF SARATOGA =ONE: GC-R (GATEWAY COMMERCIAL RURAL) USE: FOUR WINDS OF SARATOGA =ONE: GC-R (GATEWAY COMMERCIAL RURAL) USE: FOUR WINDS OF SARATOGA =ONE: GC-R (GATEWAY COMMERCIAL RURAL) USE: VACANT PROP. PERGOLA (3,550 SF) T PROP. PAVILION (3,550 SF) 5.0'11.0' 4.3'18.0'(TYP)18.0'(TYP)18.0'(TYP)18.0'(TYP)9' (TYP)9' (TYP) 9' (TYP) 9' (TYP) 67.2'29.2'22.0'11.0' 3'R 3'R 19.8' 18.0' 9' (TYP) 9' (TYP) 9' (TYP) 9' (TYP) 9' (TYP) 9' (TYP) 9' (TYP) 9' (TYP) 9' (TYP) 9' (TYP) 9' (TYP) 9' (TYP) 18' (TYP)18.0'(TYP)18.0'(TYP)18.0'(TYP)18.0'(TYP)18.0'(TYP)18.0'(TYP)18.0'(TYP)18.0'(TYP)18.0'(TYP)18.0'(TYP)18.0'(TYP)18.0'9.0'(TYP)18.0'(TYP)18.0'(TYP)18.0'(TYP)18.0'(TYP)31.0' 26.3' 13.0'13.0'13.0'13.0' 11.2' 9.0'9.0'9.0'9.0'9.0' 9.0'9.0'9.0'9.0'10.9'PROP. BUILDING (19,950 SF) PARKING = 314 SPACES 567.1' 5.0'168.8 ' PROP TIMBER BENCH PROP. LSA (TYP.) PROP. LSA (TYP.) CONCRETE PATIO OUTDOOR SEATING EMPLOYEE PARKING PROP. SWALE (TYP.) PROP. PUMP CHAMBER PROP. TRUCK DOCK PROP. ACCESSIBLE PARKING SPACES AND STRIPING (SEE DETAIL) PROP. POLE MOUNTED LIGHT (TYP.) (SEE LIGHTING PLAN) 56 BIKE SPACES. REFER TO SHEET L-601 50' WETLAND BUFFER PROP. LSA (TYP.) 50' WETLAND BUFFER PROP. ADA RAMP (TYP) PROP. FLUSH CURB ALONG ADA PARKING PROP. ADA RAMP (TYP) PROP. CONC. CURB AND CONC. SIDEWALK PROP LIMIT OF DISTURBANCE (TYP) PROP LIMIT OF DISTURBANCE (TYP) PROP TREELINE (TYP) PROP TREELINE (TYP) PROP TREELINE (TYP) PROP. "NO PARKING" SIGN IN BOLLARD (TYP OF 4)PROP. MONOLITHIC CURB AND SIDEWALK PROP DIRECTIONAL ARROWS (TYP) PROP DIRECTIONAL ARROWS (TYP) PROP DIRECTIONAL ARROWS (TYP) PROP. LSA (TYP.) PROP. MONOLITHIC CURB AND SIDEWALK PROP. FLUSH CURB PROP. FLUSH CURB PROP. STANDARD - DUTY ASPHALT PAVEMENT (TYP.) PROP. STORMWATER MANAGEMENT AREA PROP. STORMWATER MANAGEMENT AREA PROP. ONE WAY / EXIT SIGN PROP. HEAVY DUTY CONCRETE PAD PROP. ONE WAY (LEFT) / EXIT SIGN PROP. ±276 LF 4' TALL SPLIT RAIL FENCE WITH 8' GATE PROP. POROUS ASPHALT PAVEMENT (TYP.) PROP. POROUS ASPHALT PAVEMENT (TYP.) PROP. ± 545 LF 4' TALL SPLIT RAIL FENCE WITH 8' GATE PROP. CANOPY (REFER TO ARCH PLANS) (TYP) PROP. MANHOLE PROP. DIRECTIONAL SIGN (REFER TO PLANS BY ARCHITECT, SHEET A801) PROP. DIRECTIONAL SIGN (REFER TO PLANS BY ARCHITECT, SHEET A801) PROP. GREASE TRAP PROP. BOLLARDS WITH BLACK COVER AND "CURBSIDE PARKING" SIGN TO BE MOUNTED AT 7' HEIGHT (TYP OF 23) PROP. 5' LONG CURB RAMP PROP TIMBER BENCH. REFER TO SHEET L-602 PROP. GROUP/RIDE SHARE DROP OFF LOCATION PROP. DIRECTIONAL SIGN (REFER TO PLANS BY ARCHITECT, SHEET A801) PROP. DIRECTIONAL SIGN (REFER TO PLANS BY ARCHITECT, SHEET A801) PROP. DIRECTIONAL SIGN (REFER TO PLANS BY ARCHITECT, SHEET A801) PROP. SPEED BUMP (TYP) PROP. SPEED BUMP (TYP) PROP. SPEED BUMP (TYP) PROP. ±377 LF 6' HIGH STOCKADE FENCING PROP. SPEED BUMP (TYP) PROP. SPEED BUMP (TYP) PROP. SPEED BUMP (TYP) PROP PICNIC TABLE ON CONC. PAD. REFER TO SHEET L-602 PROP. TIMBER PLATFORM (TYP OF 3). REFER TO SHEET L-602 PROP. CONC. PAVEMENT PAD (TYP OF 3) PROP. LIMIT OF LANDSCAPED BED (TYP) PROP. LIMIT OF LANDSCAPED BED (TYP) PROP. LIMIT OF LANDSCAPED BED (TYP) PROP. STEEL SAFETY RAILING WITH MOUNTING SOCKETS AT LOADING DOCK, BLACK POWDERCOAT CURBSIDE PARKING PROP. DO NOT ENTER SIGN PROP. PAINTED THBC LOGO (BY VENDOR'S OWNER) (TYP OF 23) PROP. TIMBER SWING PLATFORM (TYP OF 3). REFER TO SHEET L-601 PROP.PATH BOLLARD LIGHTING (TYP). REFER TO SHEET L-602 PROP. DIRECTIONAL SIGN (REFER TO PLANS BY ARCHITECT, SHEET A801) PROP. TRANSITION CURB (TYP OF 2) PROP. CURB RAMP(TYP) PROP. TRANSITION CURB (TYP) PROP. SINGLE TESLA EV CHARGING STATION ON PEDESTAL. GC TO COORD WITH MANUFACTURER. REFER TO MEP SHEET E002 PROP. TRANSITION CURB (TYP) PROP. 4" WIDE WHITE STRIPE AT DROP OFF AREA PROP. TRENCH DRAIN PROP. LSA (TYP.) PROP. LSA (TYP.) PROP. LANDSCAPED ISLAND (TYP.) PROP. CURBED LANDSCAPED ISLAND (TYP. OF 2) PROP EDGE OF PAVEMENT (TYP) LIMIT OF PROP. EDGE OF PAVEMENT (TYP) PROP DO NOT ENTER SIGN (TYP) PROP LIMIT OF DISTURBANCE (TYP) PROP. LIMIT OF LANDSCAPED BED (TYP) PROP. 5' WIDE CONC. SIDEWALK PROP. GRAVEL STRIP (TYP) PROP. GRAVEL STRIP (TYP) PROP. CANOPY (REFER TO ARCH. PLANS) (TYP) PROP. CANOPY (REFER TO ARCH. PLANS)(TYP) PROP. LSA (TYP.) PROP EDGE OF PAVEMENT (TYP) PROP. CURBED LANDSCAPED ISLAND (TYP. OF 2) PROP EDGE OF PAVEMENT (TYP) PROP EDGE OF PAVEMENT (TYP) PROP EDGE OF PAVEMENT (TYP) PROP LIMIT OF DISTURBANCE (TYP) EXIST TREELINE TO REMAIN (TYP) PROP. CURBED LANDSCAPED ISLAND (TYP. OF 2) EXIST TREELINE TO REMAIN (TYP) LIMIT OF PROP. TREELINE (TYP) LIMIT OF PROP. TREELINE (TYP) PROP LIMIT OF DISTURBANCE (TYP) LIMIT OF PROP. TREELINE (TYP) LIMIT OF PROP. TREELINE (TYP) EXIST WETLAND BOUNDARY (TYP) EXIST WETLAND BOUNDARY (TYP) EXIST CHAIN LINK FENCE TO REMAIN (TYP) PROP. TREELINE (TYP) EXIST TREELINE TO REMAIN (TYP) LIMIT OF PROP. TREELINE (TYP) EXIST. UTILITY POLE AND GUY WIRE TO REMAIN. GC TO NOTIFY ENGINEER OF ANY CONFLICTS WITH PROPOSED FEATURES PRIOR TO CONSTRUCTION. GC TO PROVIDE APPROPRIATE CLEARANCE FOR PEDESTRIAN SIDEWALK PER ADA STANDARDS PROP LIMIT OF DISTURBANCE (TYP) PROP SAWCUT LINE (TYP) NYSDOT PAVEMENT SECTION (SEE DETAIL SHEET C-902) NYSDOT PAVING LIMIT SHALL BE MINIMUM 30' FROM THE OUTSIDE TRAVEL LANE OR EXTENDED TO THE ROW LINE, WHICHEVER IS GREATER PROP. POLE MOUNTED LIGHT (TYP.) (SEE LIGHTING PLAN) PROP. ONE-WAY INGRESS PROP SAWCUT LINE (TYP) EXIST. HYDRANT (TO REMAIN) NYSDOT PAVEMENT SECTION (SEE DETAIL SHEET C-902) NYSDOT PAVING LIMIT SHALL BE MINIMUM 30' FROM THE OUTSIDE TRAVEL LANE OR EXTENDED TO THE ROW LINE, WHICHEVER IS GREATER PROP. ONE-WAY EGRESS PROP. ONE-WAY SIGN PROP. ONE-WAY SIGN LIMIT OF PROP. EDGE OF PAVEMENT (TYP) PROP. POLE MOUNTED LIGHT (TYP.) (SEE LIGHTING PLAN) PROP. POLE MOUNTED LIGHT (TYP.) (SEE LIGHTING PLAN) PROP. DIRECTIONAL SIGN (REFER TO PLANS BY ARCHITECT, SHEET A801) ALL DISTURBED LAWN AREAS WITHIN THE NYSDOT ROW ARE TO BE RESTORED USING ITEM 610.1403TOPSOIL - LAWNS AND ITEM 610.1602 TURF ESTABLISHMENT - LAWNS (OR EQUAL) ALL DISTURBED LAWN AREAS WITHIN THE NYSDOT ROW ARE TO BE RESTORED USING ITEM 610.1403TOPSOIL - LAWNS AND ITEM 610.1602 TURF ESTABLISHMENT - LAWNS (OR EQUAL) PROP. YIELD TO PEDESTRIAN SIGN (TYP OF 2) PROP STOP BAR (TYP) PROP. MONUMENT SIGN (REFER TO PLANS BY ARCHITECT, SHEET A801) PROP. TRANSFORMER PAD PROP. 9' WIDE CONC. SIDEWALK PROP. 17'x25' TRASH ENCLOSURE ON CONC. PAD PROP. 8' WIDE CONC. SIDEWALK PROP. PATH BOLLARD LIGHTING (TYP). REFER TO SHEET L-602 PROP. HEAVY-DUTY ASPHALT PAVEMENT (TYP.) PROP. 5' WIDE CONC. SIDEWALK PROP. ±96 LF ±2' HIGH REDI-ROCK LEDGESTONE WALL WITH 6' HIGH SLAT WALL PRIVACY SCREEN MOUNTED TO BLOCK WALL. GC TO COORD DESIGN WITH GEOTECH PRIOR TO CONSTRUCTION PROP. BLACK FINISHED HANDRAIL PROP. 5' WIDE TYPE 'S' CONC. CROSSWALK (TYP) PROP. YIELD TO PEDESTRIANS SIGN (TYP OF 2) PROP. STOP AND DO NOT ENTER SIGN (TYP OF 2) PROP. GENERATOR PAD PROP. STANDARD- DUTY ASPHALT PAVEMENT (TYP.) PROP. RAISED ALUMINUM PLANTERS (TYP OF 6) REFER TO SHEET L-601 PROP. BOLLARDS (TYP OF 9) PROP. STAMPED CONCRETE. REFER TO SHEET L-601 PROP. BLACK BOLLARDS (TYP OF 3)PROP. DO NOT ENTER SIGN AND PAVEMENT MARKING PROP. 5' WIDE TYPE 'S' CONC. CROSSWALK (TYP) PROP. STOP AND DO NOT ENTER SIGNS PROP. 5' WIDE CONC. SIDEWALK REFER TO ARCH PLANS FOR PAVILION DETAILS REFER TO ARCH PLANS FOR PERGOLA DETAILS PROP. YIELD TO PEDESTRIANS SIGN (TYP OF 2) PROP. STOP AND DO NOT ENTER SIGNS LIMIT OF DISTURBANCE PROP. SIDEWALK PROP. STOP AND DO NOT ENTER SIGNS LIMIT OF PROP. SIDEWALK. GC TO TIE INTO EXIST. SIDEWALK AND ENSURE COMPLIANT SIDEWALK CONNECTION PROP. POROUS ASPHALT PAVEMENT (TYP.) PROP. CLEANOUT (TYP) PROP. 8' WIDE CROSSWALK (TYP)9'(TYP)9'(TYP)9'(TYP)PROP. TRANSITION CURB (TYP) 9' (TYP) 9' (TYP) 9' (TYP) PROP. TRANSITION CURB (TYP)9.0'456.7' PROP. DUAL TESLA EV CHARGING STATIONS ON PEDESTAL (TYP OF 4). GC TO COORD. WITH MANUFACTURER. REFER TO MEP SHEET E00218.0'(TYP) 3'R 9' (TYP) PROP. STRING LIGHTS (TYP) REFER TO SHEET L-602 77.2' 1.6' PROP. COLUMNS (REFER TO ARCH PLANS) (TYP) PROP. ADA RAMP (TYP OF 3) PROP. FLUSH CURB LIMIT OF PROP. HANDRAIL PROP. SINGLE TESLA ADA EV CHARGING STATION ON PEDESTAL WITH BOLLARD. GC TO COORD WITH MANUFACTURER AND ELECTRIC COMPANY PRIOR TO CONSTRUCTION PROP. ADA PARKING SIGN IN BOLLARD (TYP OF 9)38.9'75.0'18.0'(TYP)50.0' 20'R S PROP. CONC. CURB (TYP.)SOUTH BROADWAYU.S. ROUTE 9N 12°46'59" E 501.66'S 85°46'00" E 610.83' T S S T PROP. BUILDING (19,950 SF) PARKING = 314 SPACES LANDS N/F OF 3368 S BROADWAY HOTEL LLC INSTR. 2022-31739N 12°46'59" E 501.66'(TO REMAIN) (TO REMAIN) (TO REMAIN) SSOUTH BROADWAYU.S. ROUTE 9N 12°46'59" E 501.66'S 85°46'00" E 610.83' T LBLB LB LB LB LB LB LBBSBS BSBST T T BST S S WB 67 DELIVERY TRUCK PROP. PERGOLA (3,550 SF) T PROP. PAVILION (3,550 SF) PROP. BUILDING (19,950 SF) PARKING = 314 SPACES REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 1 2 3 4 5 6 7 8 REVISION 8 - 01/19/2024 CLIENT COMMENTS SG SW 02/02/2024 CITY COMMENTS SG VR 03/04/2024 CITY COMMENTS SG SW 03/20/2024 CITY COMMENTS SG VR 04/15/2024 CITY AND TDE COMMENTS AKD SRW 05/03/2024 PRELIMINARY ISSUE FOR CONSTRUCTION AKD SRW 06/07/2024 DOT AND SCSD COMMENTS AKD SRW 06/14/2024 ADDENDUM 1 AKD SRW 06/14/2024 DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR P:\2023\NYB230191.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\NYB230191.00-SPPD-0A----->LAYOUT: C-301 SITEADTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NYB230191 SAG/AKD SRW 11/30/2023 NYB230191.00-SPPD-0A PROPOSED SITE PLAN DOCUMENTS THBC NY, LLC PROPOSED DEVELOPMENT SEC. 178.00 - BLK 2 - PARCEL 15 SOUTH BROADWAY CITY OF SARATOGA SPRINGS SARATOGA COUNTY, NEW YORK ISSUED FOR CONSTRUCTION ALWAYS CALL 811 It's fast. It's free. It's the law.TMTHE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER17 COMPUTER DRIVE WEST ALBANY, NY 12205 Phone:(518) 438-9900 Fax: (518) 438-0900 www.BohlerEngineering.com W E S 1"=40' 0 40102040 C-301 SITE LAYOUT PLAN Steering Angle Lock to Lock Time Articulating Angle WB-67 Trailer Track Tractor Track Trailer Width Tractor Width 21.604.00 feet 8.50 8.50: 8.00 8.00 : : : 0.00 4.00 45.40 15.00 51.90 : : :6.0 31.9 75.0 THIS PLAN TO BE UTILIZED FOR SITE LAYOUT PURPOSES ONLY. REFER TO GENERAL NOTES SHEET FOR ADDITIONAL NOTES SITE INFORMATION 1.APPLICANT: THBC NY, LLC PO BOX 4637, 160 WEST AVE SARATOGA SPRINGS, NY 12866 2.OWNER: MCJACK LLC 17 QUENNEVILLE DR MOREVILLE, VT, 05660 3.PARCEL: 178.00-2-15 3376 SOUTH BROADWAY CITY OF SARATOGA SPRINGS SARATOGA COUNTY, NEW YORKMIN. CORNER SIDE SETBACK 40 FT N/A 168.8 FT MIN. BUILDING HEIGHT 18 FT*N/A 32.7 FT USE/CATEGORY: MICRO-PRODUCTION OF ALCOHOL REQUIRED PARKING:1 SPACE PER 500 SF 1,100 SF / 500 = 2 SPACE MAX. NUMBER OF PARKING SPACE ALLOWED PER SARATOGA SPRINGS UDO: 120% OF REQUIRED MINIMUM - 262 x 120% = 314 SPACES N/A - NOT APPLICABLE N/S - NOT SPECIFIED (V) - VARIANCE REQUESTED (W) - WAIVER REQUESTED (E) - EXIST. NON-CONFORMANCE ZONING ANALYSIS TABLE ZONE CRITERIA REQUIRED EXISTING PROPOSED MIN. LOT AREA MIN. LOT WIDTH MAX. BLDG COVERAGE MIN. FRONT SETBACK MIN. SIDE SETBACK MIN. REAR SETBACK MAX. BUILDING HEIGHT MAX. IMPER. COVERAGE PARKING SPACES ACCESS. PARKING SPACES GATEWAY COMMERCIAL - RURAL (GC-R)ZONING DISTRICT MICRO-PRODUCTION OF ALCOHOL - PERMITTED PRINCIPAL USE EATING AND DRINKING ESTABLISHMENT - PERMITTED PRINCIPAL USE OUTDOOR DINING - SPECIAL USE, PRINCIPAL USE USES 20,000 SF* 100 FT 35% 60 FT* 20 FT 25 FT 40 FT 60% 262 SPACES 10.68 ACRES 500 FT 0% N/A N/A N/A N/A 2.2% 29 SPACES UNCHANGED - 4.3% 114.6 FT 100.1 FT 567.1 FT 39% 314 SPACES 8 SPACES 1 SPACE 9 SPACES PARKING STALL CRITERIA STANDARD:9 FT x 18 FT COMPACT: 8 FT x 16 FT USE/CATEGORY: EATING AND DRINKING REQUIRED PARKING:1 SPACE PER 100 SF 25,938 SF / 100 = 260 SPACES * SEE EXCEPTIONS TO THESE REQUIREMENTS AS SPECIFIED IN SECTION 4.0.A UNCHANGED 32.7 FT ALLOWED PROPOSED FREESTANDING SIGN SIGNAGE TABLE (1) 12 SF MAX (8' TALL) GC TO REFER TO LATEST SIGN PACKAGE BY ARCHITECT. WHERE DISCREPANCIES OCCUR, ARCHITECTURAL SIGN PACKAGE SHALL GOVERN. (1) INTERNALLY ILLUMINATED LOGO SIGN: 196 SFBUILDING MOUNTED SIGN WEST ELEVATION 1.5 SF PER LINEAR FOOT OF BUILDING WALL. (278 SF MAX.) (1) INTERNALLY ILLUMINATED WORKMARK SIGN: 198 SFBUILDING MOUNTED SIGN SOUTH ELEVATION BUILDING MOUNTED SIGN EAST ELEVATION (1) INTERNALLY ILLUMINATED LOGO SIGN: 196 SF 1.5 SF PER LINEAR FOOT OF BUILDING WALL. (271.5 SF MAX.) 1.5 SF PER LINEAR FOOT OF BUILDING WALL. (271.5 SF MAX.) (1) INTERNALLY ILLUMINATED, DOUBLE SIDED MONUMENT SIGN: 10.5 SF (8' TALL) DELIVERY TRUCK SPECIFICATIONS Turning Radius :44.80 ANY WORK PROPOSED WITHIN THE NYSDOT ROW WILL REQUIRE A PERMIT FROM NYSDOT. GC TO COORDINATE ALL PERMIT REQUIREMENTS WITH NYSDOT PRIOR TO CONSTRUCTION. NORTHERLY EGRESS TRUCK TURN SCALE: 1" = 50' SOUTHERLY ACCESS TRUCK TURN SCALE: 1" = 50' NORTHERLY INGRESS TRUCK TURN SCALE: 1" = 50' LANDS N/F OFEFF-JAY REALTY, LLCBK. 1676, PG. 73SECTION 178.00 BLOCK 2 LOT 17.11LANDS N/F OF3368 S BROADWAY HOTEL LLCINSTR. 2022-31739SECTION 178.00 BLOCK 2 LOT 16LANDS N/F OFF.W. OF SARATOGA, INC.BK. 1099, PG. 477SECTION 178.00 BLOCK 2 LOT 17.2LANDS N/F OFF.W. OF SARATOGA, INC.BK. 1078, PG. 336SECTION 178.00 BLOCK 2 LOT 11.1LANDS N/F OFF.W. OF SARATOGA, INC.BK. 1498, PG. 47SECTION 178.00 BLOCK 2 LOT 23LANDS N/F OF3402 ROUTE 9, LLCINSTR. 2013-43252SECTION 178.00 BLOCK 2 LOT 22N 12°46'59" E 501.66'S 85°46'00" E 610.83'N 10°13'59" E 7 3 . 9 6 'N 86°12'05" E 170.93'N 86°41'18" E 107.94'S 11°54'18" W 6 1 7 . 3 5 'N 85°30'00" W 887.00'WETLAND "A"AREA=0.53 ACRESEEEEEEEETTTTWWWWWGGGGGFM FM FM FM FM FM FM FM FM FM FM FM FM SSSC/OSC/OS(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO RE M A I N )(TO REMAIN)PROP.PERGOLA(3,550 SF)TPROP.PAVILION(3,550 SF)PROP.BUILDING(19,950 SF)PARKING = 314 SPACESWWWW>>>>>>>>>>>>306306 >>>>>>ROOF DRAININV = 305.90ROOF DRAININV = 306.50PROP. 187 LF - 6'' PERF.HDPE IN STONES= 1.0%PROP. 15' WIDEOVERFLOW SPILLWAYELEV: 302.90PROP. INFILTRATION BASINBOTT. ELEV: 302.001 YR PEAK ELEV = 302.0010 YR PEAK ELEV = 302.14100 YR PEAK ELEV = 302.9518" OUTLET CONTROLSTRUCTURE WITH TRASH RACKRIM=302.803" ORIFICEINV=302.00INV = 304.75PROP. INFILTRATION BASINBOTT. BASIN = 302.001 YR PEAK ELEV = 302.0010 YR PEAK ELEV = 302.40100 YR PEAK ELEV = 303.80INV = 303.00PROP. SWALEPROP. METAL END SECTIONINV = 303.45PROP. 62 LF - 24'' HDPES= 0.5%RIDGELINE RIDGELINE INV=301.85PROP. METAL END SECTIONINV = 303.75PROP. METAL END SECTIONINV = 304.11PROP. 58 LF - 24'' HDPES= 0.5%PROP. METAL END SECTIONINV = 304.40PROP. POROUSPAVEMENT (TYP)G.C.TO ENSURE 2% MAX.SLOPE IN ACCESSIBLE AREAS306RIDGE LINE307 308 RIDGE LINE FFE = 309.00PROP. 459 LF - 8'' PERF. HDPES= 0.31%INV = 305.00PROP. TRENCH DRAINRIM = 305.00INV. = 304.00308307308308306 305305302303 304306 307 305306 305 304306307308308PROP. POROUSPAVEMENT (TYP)PROP. POROUSPAVEMENT (TYP)INV = 304.00305305 306306306307305305 303 303 304 304 302 303 303 304 304 3'PROP. VEGETATED SWALE -BASE 3' WIDE @ 0.6%PROP. 10' WIDEOVERFLOW SPILLWAYELEV: 304.25INV = 302.50INV = 303.00PROP. 61 - 18'' HDPES= 0.7%INV=301.70PROP. 32 - 6'' HDPES= 0.5%PROP. ACCESSIBLE ROUTE GC TOENSURE MAX 5% RUNNING SLOPE& MAX. 2% CROSS SLOPEPROP. ACCESSIBLE ROUTE GC TOENSURE MAX 5% RUNNING SLOPE& MAX. 2% CROSS SLOPEG.C. TO CONFIRM 2%MAXIMUM SLOPE IN ALLDIRECTIONS IN BIKE RACKAREAG.C. TO CONFIRM 2%MAXIMUM SLOPE IN ALLDIRECTIONS ON OUTSIDEPATIO AREA309307309308308307309309309 306307306307307307 PROP. 3.5' WIDE DRY SWALEBOTT. ELEV = 306.50224 LF 6" PERF HDPE @ 0.5% IN 12" GRAVEL(REFER TO DETAIL ON SHEET C-902)PROP. PEA GRAVELDIAPHRAGM(2'W X 145'L X 1'D)306307305 305306307307 307308PROP. 12" STANDPIPEWITH DOME GRATEELEV = 307.00INV = 303.50305 302303304306 302 303 303 303 304304 307PROP. STONE CHECK DAM3053043063053043053033033043043 0 4306306 302302303304305304305303304305RIDGELINEROOF DRAININV = 305.90ROOF DRAININV = 306.50PROP. 58 LF - 6'' HDPES= 4.9%PROP. 212 LF - 6'' PERF.HDPE IN STONES= 0.57%INV = 303.67PROP. 302 LF - 6'' PERF.HDPE IN STONES= 0.3%PROP. 1.5' WIDE GRAVELDIAPHRAGM TO COLLECTRUNOFF FROM SCUPPERS.COORD SCUPPER LOCATIONSWITH ARCH. PLANSPROP. 107 LF - 12'' HDPES= 0.5%TOP OF BERMELEV: 304.00PROP. ACCESSIBLE ROUTE GC TOENSURE MAX 5% RUNNING SLOPE& MAX. 2% CROSS SLOPEPROP. ACCESSIBLE ROUTE GC TOENSURE MAX 5% RUNNING SLOPE& MAX. 2% CROSS SLOPEPROP. ACCESSIBLE ROUTEGC TO ENSURE MAX 5%RUNNING SLOPE & MAX.2% CROSS SLOPEPROP. ACCESSIBLE ROUTE GC TOENSURE MAX 5% RUNNING SLOPE& MAX. 2% CROSS SLOPEPROP. ACCESSIBLE ROUTE GC TOENSURE MAX 5% RUNNING SLOPE& MAX. 2% CROSS SLOPE305304304305306PROP. CLEANOUT PLACED EVERY ±100'INV 303.45END SOLID HDPE PIPE AND BEGINPERFORATED HDPE PIPEPROPCLEANOUTPLACEDEVERY±100' (TYP)PROPCLEANOUTPLACEDEVERY±100' (TYP)PROP CLEANOUTPLACED EVERY ±100'(TYP)PROP CLEANOUTPLACED EVERY±100' (TYP)PROPCLEANOUTPLACEDEVERY±100' (TYP)PROP CLEANOUTPLACED EVERY±100' (TYP)PROPCLEANOUT(TYP)PROP. 290 LF -8" HDPE S=0.31%RIDGE LINE308RIDGE LINE >>> >>PROP. CROSSINGINV 6" = 305.67CROWN 8" = 304.31>>> >>>>>>>>>>>>>PROP. ACCESSIBLEROUTE SURROUNDINGBOCCE COURT>>>>TC=BC 308.81TC 308.86BC 308.53TC 308.82BC 308.49309.00309.00308.46307.75308.47308.77307.50307.55306.45306.42308.71308.74308.98307.80307.75307.64307.67BW 306.79309.00306.90BW 305.00309.00309.00TW 309.00306.53306.65306.56306.45306.37306.14306.12306.36306.24305.98304.65304.52305.21305.21305.75TC 305.74BC 305.24TC 305.74BC 305.24304.84304.81304.48304.50304.41304.25303.84304.07304.22304.25304.10304.42304.54304.57304.45304.77304.79304.86304.84304.92305.07305.08304.89TC 305.79BC 305.29TC 305.78BC 305.28305.34305.35305.47305.60305.26305.15304.92305.12305.14304.93305.62305.63306.05306.04TC 306.88BC 306.38TC 306.95BC 306.45TC 306.97BC 306.47TC 306.97BC 306.47306.14305.77305.29305.27305.07305.08305.50305.20306.32307.48307.48307.20TC 308.61BC 308.28TC 308.64BC 308.31TC=BC 308.83307.65307.54307.46307.24307.32307.40306.94307.04307.26307.25307.29307.55307.41309.00309.00309.00309.00308.68309.00309.00309.00309.00305.74306.42306.52307.03307.15306.92306.79308.14308.20308.20308.68309.00309.00308.31308.18306.96306.90306.51306.57306.09306.16305.90305.94305.26305.10304.98305.00304.66304.63309.00309.00308.66308.84307.0+/-ME307.5± ME307.4± METC 307.12BC 306.62TC=BC 306.66TC=BC 306.62TC 305.95BC 305.45TC 305.95BC 305.45TC 306.23BC 305.73TC 306.21BC 305.71TC 305.98BC 305.48TC 306.00BC 305.50TC 305.85BC 305.35TC 308.85BC 308.52TC 308.85BC 308.52304.80304.82304.98304.99305.32305.43305.83305.84305.98305.97304.64304.65TC 307.30BC 306.80TC 307.15BC 306.65TW 309.00308.95TW 308.90TC 307.29BC 306.79TC 307.43BC 306.93307.1+/-ME307.41BW 305.00308.37308.42307.58307.55TC=BC 306.71306.78306.71306.81307.35306.61307.11307.31307.45306.77306.93306.60306.80307.71306.80306.95304.66308.24305.66306.00305.50305.43305.67307.67TC 305.91BC 305.41TC=BC 306.06307.06308.84308.47BW 308.65309.00BW 306.18TW 306.19308.10308.95307.63307.71305.50307.50308.50307.5± ME307.30306.30307.83305.10305.17308.13308.04308.55308.95309.00308.01306.39306.79307.21307.46307.77307.19305.63307.45307.69307.74307.78307.86307.94307.99307.36305.97306.24306.56306.09307.01307.96306.44306.43306.43306.42306.42306.42306.41306.41305.50305.50TC 305.85BC 305.35TC 305.87BC 305.37305.78305.79306.43306.42TC=BC 306.69308.95308.60309.00305.37304.69304.81304.80304.47305.13304.05304.06304.28305.38TC=BC 306.96309.00309.00308.82308.93307.0+/-ME309.00309.00309.00308.90308.90308.74308.82308.61307.46308.07308.16307.35308.36305.81305.80305.71305.70306.96307.0+/-ME307.30307.31307.57307.42307.83307.85307.42307.37308.24308.67305.71305.50304.33305.52305.55308.60308.75308.55307.48305.76307.50309.50309.50305.50303.60304.95306.15306.63306.72307.20307.28307.72TW 306.67TW 306.76TW 307.24TW 307.33TW 307.77BW 306.21BW 306.21BW 306.27BW 306.29BW 306.32309.00TW 308.90308.92TC 308.62BC 308.12TC 308.93BC 308.43TC 309.00BC 308.50TC 308.96BC 308.46308.58BW 306.80TW 308.10GC TO PROTECTEXIST. WETLANDSDURINGCONSTRUCTIONPROPCLEANOUT(TYP)INV = 305.40PROP. CROSSINGINV 6" = 305.57CROWN 8" = 304.76PROP. ACCESSIBLE ROUTEGC TO ENSURE MAX 5%RUNNING SLOPE & MAX. 2%CROSS SLOPEFFE = 309.00ROOF DRAININV = 306.50PROP. ACCESSIBLEROUTE GC TOENSURE MAX 5%RUNNING SLOPE &MAX. 2% CROSSSLOPEPROP. 131 LF - 6'' HDPES= 0.38%308.18302302INV = 303.85SEE DETAILEDGRADING IN"INSET 'A'" THISSHEET.S>>>>>>>>>>306.05306.04TC 306.88BC 306.38TC 306.95BC 306.45TC 306.97BC 306.47TC 306.97BC 306.47306.14306.92306.79TC 307.12BC 306.62TC=BC 306.66TC=BC 306.62TC 307.30BC 306.80TC 307.15BC 306.65TC 307.29BC 306.79TC=BC 306.71306.78306.71306.81307.35306.61307.11306.44306.43306.43306.42306.42306.42306.41306.41306.43306.42TC=BC 306.69309.50309.50306.71306.72306.74306.75306.77306.71306.71306.71306.65306.71306.75306.78306.82306.85306.89306.78306.79306.80306.41306.42306.43REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY12345678REVISION 8 -01/19/2024CLIENT COMMENTSSGSW02/02/2024CITY COMMENTSSGVR03/04/2024CITY COMMENTSSGSW03/20/2024CITY COMMENTSSGVR04/15/2024CITY AND TDECOMMENTSAKDSRW05/03/2024PRELIMINARY ISSUEFOR CONSTRUCTIONAKDSRW06/07/2024DOT AND SCSDCOMMENTSAKDSRW06/14/2024ADDENDUM 1AKDSRW06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORP:\2023\NYB230191.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\NYB230191.00-SPPD-0A----->LAYOUT: C-401 GRAD_DRAINAD THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191SAG/AKDSRW11/30/2023NYB230191.00-SPPD-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK 2 - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comTHIS PLAN TO BE UTILIZED FOR SITEGRADING AND DRAINAGE PURPOSESONLY. REFER TO GENERAL NOTESSHEET FOR ADDITIONAL GRADING &UTILITY NOTES1"=40'040102040C-401GRADING &DRAINAGEPLANWESB-2B-1TP-1I-ICPT-1B-3TP-7I-7CPT-2B-4B-5TP-8I-8TP-4I-4TP-2I-2TP-6I-6TP-5I-5TP-3I-3LEGENDB-1TP-1I-1CPT-1BORING LOCATIONTEST PIT LOCATIONINFILTRATION TESTCONE PENETRATION TESTNOTE: ALL LOCATIONS ARE APPROXIMATE.REFERENCE-REFER TO GEOTECHNICAL INVESTIGATION BY WHITESTONEENVIRONMENTAL & GEOTECHNICAL ENGINEERS &CONSULTANTS PERFORMED: JANUARY 9, 2024ANY WORK PROPOSED WITHIN THENYSDOT ROW WILL REQUIRE A PERMITFROM NYSDOT. GC TO COORDINATE ALLPERMIT REQUIREMENTS WITH NYSDOTPRIOR TO CONSTRUCTION.INSET 'A'SCALE: 1"=20' LB LBLBLBLBLBLBLBLBEEEEEEEETTTTWWWWWGGGGGFM FM FM FM FM FM FM FM FM FM FM FM FM SSSSSPROP. 167 LF 8" DIP WATER SERVICE, MINIMUM 5' COVER.ALL WORK SHALL BE COORDINATED WITHARCHITECTURAL PLANS PRIOR TO THE START OFCONSTRUCTION.GC TO COORDINATE WITH UTILITY COMPANYTO ENSURE OVERHEAD LINES ARE A MINIMUMOF 14' ABOVE FINISHED GRADE. EXIST.OVERHEAD WIRES MAY NEED TO BEADJUSTED. GC TO CONFIRM WIRE HEIGHTAND COORDINATE WITH UTILITY PROVIDERPRIOR TO CONSTRUCTION.PROP SEWER MANHOLE (RIM = 304.45) TO CONNECT TO EXISTING 4" SANITARY STUB (TO BE COORDINATEDWITH UTILITY COMPANY, CITY OF SARATOGA SPRINGS AND SARATOGA COUNTY PRIOR TO THE START OFCONSTRUCTION). GC TO CONFIRM DEPTH, EXACT LOCATION AND INVERT OF EXIST. SANITARY PRIOR TOCONSTRUCTION AND NOTIFY ENGINEER. G.C. TO CONNECT PROPOSED UNDERGROUNDGAS SERVICE TO EXISTING MAIN. CONTRACTORTO COORDINATE SIZE AND TYPE OF SERVICEWITH UTILITY PROVIDER AND ARCHITECTURALPLANS PRIOR TO THE START OF CONSTRUCTIONPROP UNDERGROUND ELECTRIC,TELECOM SERVICE CONNECTIONS (GC TOCOORDINATE WITH UTILITY COMPANYPRIOR TO THE START OF CONSTRUCTION)GC TO COORDINATE SIZE AND LOCATION OFALL UTILITY CONNECTIONS TO BUILDINGWITH ARCHITECTURAL AND MEP PLANSPRIOR TO THE START OF CONSTRUCTION.PROP. TAPPING SLEEVE AND VALVE CONNECTION TO 8"CITY WATER MAIN. GC TO COORDINATE CONNECTIONWITH THE CITY OF SARATOGA SPRINGS PRIOR TO THESTART OF CONSTRUCTION. IF NECESSARY, ANY PITS(DEPTH >5') WITHIN 10' OF THE EDGE OF PAVEMENT WILLREQUIRE SHEETING AND SHORING. SHOULD THESHEETING AND SHORING BE FLUSH WITH THE SURFACE,PITS MAY BE COVERED WITH A STEEL PLATE. IF NOT,TEMPORARY CONCRETE WILL BE REQUIRED. ALLSHEETING AND SHORING, IF REQUIRED, SHALL FOLLOWNYSDOT STANDARD SPECIFICATION SECTION 552.GC TO COORDINATE ALL UTILITY SERVICES TOPAVILION INCLUDING, BUT NOT LIMITED TO,SIZE, TYPE, NUMBER OF CONDUITS ANDLOCATION WITH ARCHITECTURAL AND MEPPLANS PRIOR TO CONSTRUCTION (TYP)GC TO COORDINATE ALL UTILITY SERVICESTO PERGOLA INCLUDING, BUT NOT LIMITED TO,SIZE, TYPE, NUMBER OF CONDUITS ANDLOCATION WITH ARCHITECTURAL AND MEPPLANS PRIOR TO CONSTRUCTION (TYP)PROP. ELECTRIC BACKUP GENERATOR ON CONC. PAD.10.0' (MIN)5.0' (MIN)(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO RE M A I N )(TO REMAIN)PROP.PERGOLA(3,550 SF)TPROP.PAVILION(3,550 SF)PROP.BUILDING(19,950 SF)PARKING = 314 SPACESWWWWPROP. FIRE DEPARTMENTCONNECTION. GC TOCOORDINATE WITHARCHITECTURAL PLANS,TOWN AND FIREDEPARTMENT.PROP. ELECTRIC TRANSFORMER ON CONC.PAD. SEE "TRANSFORMER NOTE" THIS SHEETPROP. WATER VALVE (TYP)GC TO COORDINATE ALL ELECTRIC SERVICESTO EV CHARGING STATIONS INCLUDING, BUTNOT LIMITED TO, SIZE, TYPE, NUMBER OFCONDUITS AND LOCATION WITHARCHITECTURAL PLANS AND UTILITYCOMPANY PRIOR TO CONSTRUCTION(TYP)SCALE: 1"= 40 ' HORIZONTAL 1"= 4 ' VERTICALProposed Gas Service Profile0+00SCALE: 1"= 40 ' HORIZONTAL 1"= 4 ' VERTICALProposed Water Service ProfileSCALE: 1"= 40 ' HORIZONTAL 1"= 4 ' VERTICALProposed Sanitary Service ProfilePROP. SCHIER GREASEINTERCEPTOR MODEL: GB-1500RIM = 308.51INV. (IN) = 305.25INV. (OUT) = 305.00UNIT TO BE INSTALLED PERMANUFACTURER INSTALLATIONINSTRUCTIONS.PROP. CLEANOUT56 LF - 6" SDR-26 PVC @2.0%PROP.PUMP CHAMBERWITH DUPLEX PUMPMODEL HVS200M0-2-HP(BY EMMONS PUMP)RIM = 307.95INV. (IN) = 303.80INV (OUT) = 304.05PROP. SEWER CONNECTION TO BUILDINGINV. = 306.00. GC TO COORDINATE SEWER AND VENTLOCATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION36 LF - 6" SDR-26 PVC @2.1%PROP. SANITARYMANHOLERIM = 308.42INV. (IN) = 304.88INV. (OUT) = 304.786 LF - 6" SDR-26PVC @2.0%49 LF - 6"SDR-26 PVC@2.0%PROP. BACKFLOWPROTECTION TO BE DESIGNEDBY MEP-FP ENGINEERGC TO MAINTAIN MIN. 3'COVER OVER GAS LINE AND5' COVER OVER WATER LINEAT PROP. SWALEFFE = 309.00PROP. 123 LF OF 6" FIRE LINE. GCTO COORD. SERVICE MATERIALWITH ARCHITECT PRIOR TOCONSTRUCTION.PROP. THRUSTBLOCK (TYP)PROP. FIRE LINECONNECTION TOBUILDINGPROP. 4" WATER SERVICECONNECTION TO BUILDINGEXIST. HYDRANT AND SERVICE (TO REMAIN)PROP. ELECTRIC SERVICEPROP. ELECTRICSERVICEPROP.TELECOMSERVICEPROP. 379 LF - 2" SDR-11 HDPE SANITARYFORCE MAIN LINE TO CONNECT TOEXISTING 4" FORCE MAIN LATERALSPROP. ±160 LF OF 2" PLASTIC GAS SERVICE,MINIMUM 3' COVER. GC TO COORDINATE WITHARCHITECTURAL PLANS AND UTILITY PROVIDERPRIOR TO THE START OF CONSTRUCTION.DATUM ELEV300.003103100+00307.850+50PROPOSEDGRADEEXISTINGGRADE-2.26%-22.57%0.66%-1.38%-18.29%22.61%9.94%2.17%PROP. GASSERVICE (MIN.3' COVER)PROP.CONNECTIONTO EXISTGAS MAINDATUM ELEV300.003103100+00306.480+50307.880+75308.34 -2.26%0.68%-20.76%-19.02%21.71%9.83%2.17%PROPOSEDGRADEEXISTINGGRADEPROP. 8" WATER SERVICE(MIN. 3' COVER)PROP.CONNECTIONTO EXIST.WATER MAINAPPROX.LOCATION OFEXIST. GAS MAINDATUM ELEV300.003103103.99%-9.21%2.50%-0.34%EXISTINGGRADEPROP.CONNECTIONTO EXIST.4" FORCEMAINPROP. 2"FORCEMAIN (MIN.3' COVER)REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY12345678REVISION 8 -01/19/2024CLIENT COMMENTSSGSW02/02/2024CITY COMMENTSSGVR03/04/2024CITY COMMENTSSGSW03/20/2024CITY COMMENTSSGVR04/15/2024CITY AND TDECOMMENTSAKDSRW05/03/2024PRELIMINARY ISSUEFOR CONSTRUCTIONAKDSRW06/07/2024DOT AND SCSDCOMMENTSAKDSRW06/14/2024ADDENDUM 1AKDSRW06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORP:\2023\NYB230191.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\NYB230191.00-SPPD-0A----->LAYOUT: C-501 UTILAD THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191SAG/AKDSRW11/30/2023NYB230191.00-SPPD-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK 2 - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comTHIS PLAN TO BE UTILIZED FORUTILITIES PURPOSES ONLY. REFER TOGENERAL NOTES SHEETFOR ADDITIONAL GRADING & UTILITYNOTES1"=40'040102040C-501UTILITY PLANGC SHALL PROVIDE ALLAPPURTENANCES IN ACCORDANCEWITH UTILITY COMPANYSPECIFICATIONS AND CARRY SAME INBASE BID. APPURTENANCES SHALLINCLUDE, BUT NOT BE LIMITED TO, THECONCRETE PAD, SECONDARY SPILLCONTAINMENT AREAS (IF REQUIRED),BOLLARD / VEHICULAR PROTECTION,AND OTHER ITEMS AS MAY BEREQUIRED BY THE UTILITY PROVIDERFOR INSTALLATION OF THETRANSFORMER. GC SHALL COORDINATEALL ASPECTS OF INSTALLATION WITHUTILITY PROVIDER PRIOR TO ORDERINGOF MATERIALS AND NOTIFY DESIGNENGINEER OF ANY CONFLICTS INWRITING.TRANSFORMER NOTE:WESANY WORK PROPOSED WITHIN THENYSDOT ROW WILL REQUIRE A PERMITFROM NYSDOT. GC TO COORDINATE ALLPERMIT REQUIREMENTS WITH NYSDOTPRIOR TO CONSTRUCTION.PROPOSED GAS SERVICE PROFILESCALE: 1"=40'PROPOSED WATER SERVICE PROFILESCALE: 1"=40'PROPOSED SANITARY SERVICE PROFILESCALE: 1"=40'SCSD REQUIRES THAT ALL MANHOLESWITHIN PROPOSED PROJECT BEVACUUM TESTED PER ASTM C-1244STANDARDS SOUTH BROADWAYU.S. ROUTE 9 LANDS N/F OFEFF-JAY REALTY, LLCBK. 1676, PG. 73SECTION 178.00 BLOCK 2 LOT 17.11LANDS N/F OF3368 S BROADWAY HOTEL LLCINSTR. 2022-31739SECTION 178.00 BLOCK 2 LOT 16LANDS N/F OFF.W. OF SARATOGA, INC.BK. 1099, PG. 477SECTION 178.00 BLOCK 2 LOT 17.2LANDS N/F OFF.W. OF SARATOGA, INC.BK. 1078, PG. 336SECTION 178.00 BLOCK 2 LOT 11.1LANDS N/F OFF.W. OF SARATOGA, INC.BK. 1498, PG. 47SECTION 178.00 BLOCK 2 LOT 23LANDS N/F OF3402 ROUTE 9, LLCINSTR. 2013-43252SECTION 178.00 BLOCK 2 LOT 22S F SF SFSFSFSFSFSFSFSFSF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SFEEEEEEEETTTTWWWWWGGGGGFMFMFMFMFMFMFMFMFMFMFMFMFMSSSSSAREA OF DISTURBANCE=±9.87 ACRESPHASE 1AREA = ±4.85 ACRESPHASE 2AREA = 4.03 ACRESPHASE 3AREA = ±0.99 ACRESPHASE 1AREA = ±4.85 ACRES=ONE: GC-R(GATEWAY COMMERCIAL RURAL)USE: HOMEWOOD SUITES=ONE: GC-R(GATEWAY COMMERCIAL RURAL)USE: SARATOGA HONDA=ONE: GC-R(GATEWAY COMMERCIAL RURAL)USE: FOUR WINDS OF SARATOGA=ONE: GC-R(GATEWAY COMMERCIAL RURAL)USE: FOUR WINDS OF SARATOGA=ONE: GC-R(GATEWAY COMMERCIAL RURAL)USE: FOUR WINDS OF SARATOGA=ONE: GC-R(GATEWAY COMMERCIAL RURAL)USE: VACANTPROP.PERGOLA(3,550 SF)TPROP.PAVILION(3,550 SF)PROP.BUILDING(19,950 SF)PARKING = 314 SPACESWWWW50.0MIN.>>>>>>>>>>>>306306 >>>>>>306307 308308 307308308306 305305302303 304306 307 305306 305 304306307308308 305305 306306306307305305 303 303 304 304 302 303 303 304 304 3'309307309308308307309309309 306307306307307307 306307305 305306307307 307308305302303304306 302 303 303 303 304304 3073053043063053043053033033043043 0 4306306 302302303304305304305303304305305304304305306SCALE: 1"= 40 ' HORIZONTAL 1"= 4 ' VERTICALProposed Gas Service Profile0+00SCALE: 1"= 40 ' HORIZONTAL 1"= 4 ' VERTICALProposed Water Service ProfileSCALE: 1"= 40 ' HORIZONTAL 1"= 4 ' VERTICALProposed Sanitary Service Profile308 >>> >>>>> >>>>>>>>>>>>>>>>>302302PROP. STABILIZEDCONSTRUCTIONENTRANCE/EXITTEMPORARY SOILSTOCKPILE AREASURROUNDED BYHAYBALES ANDSILTFENCEPROP. DOUBLE ROWSILTATION FENCE ALONGWETLAND BOUNDARY (TYP.)TEMPORARY SEDIMENT BASININFILTRATION AREA SHALLNOT BE USED FORTEMPORARY SEDIMENTTRAP (TYP)CONCRETE WASHOUTCONSTRUCT TEMPORARY SWALESAND BERMS AS NEEDED TO CONVEYSTORMWATER FROM DISTURBEDAREAS TO TEMP. SETTLING BASIN.PROP. STONE CHECK DAM (TYP.)CONSTRUCT TEMPORARY SWALESAND BERMS AS NEEDED TO CONVEYSTORMWATER FROM DISTURBEDAREAS TO TEMP. SETTLING BASIN.TEMPORARY STONE OUTLETELEV = 303.80PROP. LIMIT OFWORK (TYP)PROP. LIMIT OFWORK (TYP)PROP. LIMIT OFWORK (TYP)PROP. LIMIT OFWORK (TYP)SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFPROP. SILTATION FENCE (TYP.)SFSFSFSFSFSF305304303302PROP. STRAW BALEPROTECTION ATFLARED ENDSECTIONS (TYP)PROP. SILTATIONFENCE (TYP.)PROP.SILTATIONFENCE (TYP.)LIMIT OF PROP. SILT FENCELIMIT OF PROP. SILT FENCELIMIT OF PROP. SILT FENCELIMIT OF PROP. SILT FENCEPROP. STRAW BALEPROTECTION ATFLARED ENDSECTIONS (TYP)SLIMIT OF PROP. SILT FENCELIMIT OF PROP.SILT FENCELIMIT OF PROP.SILT FENCELIMIT OF PROP. SILT FENCEINFILTRATION AREA SHALL NOTBE USED FOR TEMPORARYSEDIMENT TRAP (TYP)REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY12345678REVISION 8 -01/19/2024CLIENT COMMENTSSGSW02/02/2024CITY COMMENTSSGVR03/04/2024CITY COMMENTSSGSW03/20/2024CITY COMMENTSSGVR04/15/2024CITY AND TDECOMMENTSAKDSRW05/03/2024PRELIMINARY ISSUEFOR CONSTRUCTIONAKDSRW06/07/2024DOT AND SCSDCOMMENTSAKDSRW06/14/2024ADDENDUM 1AKDSRW06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORP:\2023\NYB230191.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\NYB230191.00-SPPD-0A----->LAYOUT: C-601 EROSAD THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191SAG/AKDSRW11/30/2023NYB230191.00-SPPD-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK 2 - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comREFER TO SOIL EROSION CONTROLNOTES & DETAIL SHEET FOR EROSIONNOTES AND DETAILSTHIS PLAN TO BE UTILIZED FOR SITESOIL AND EROSION CONTROLPURPOSES ONLY1"=40'040102040C-601SOIL EROSION SEDIMENTCONTROL PLANWESTHE FOLLOWING CONSTRUCTION SEQUENCE IS RECOMMENDED:PHASE I1.ATTENDANCE OF PRE-CONSTRUCTION MEETING TOWN, DESIGN ENGINEER AND CERTIFIEDSWPPP INSPECTOR.2. INSTALLATION OF STABILIZED CONSTRUCTION ENTRANCE/EXIT AND GATED ACCESS (ASSHOWN).3. INSTALLATION OF SILT FENCE (AS SHOWN).4. INSPECTION AND APPROVAL OF EROSION AND SEDIMENT CONTROL INSTALLATION ANDPRACTICES BY THE CERTIFIED SWPPP INSPECTOR.5. INSTALLATION OF TEMPORARY SEDIMENT BASIN (AS SHOWN).6.GRADE SWALE ALONG SOUTHERN PROPERTY LINE, INSTALL STONE CHECK DAMS, SEED ANDMULCH SWALE.7.INSTALLATION OF TEMPORARY SWALES AS NEEDED TO DIVERT ALL STORMWATER FROMDISTURBED AREAS TO PROPOSED TEMPORARY SEDIMENT TRAPS.8.CLEARING AND GRUBBING AS REQUIRED FOR CONSTRUCTION.9.DEMOLITION OF EXISTING SITE PAVEMENT AND AMENITIES (SEE DEMOLITION PLAN)10.ADD STONE SUB-GRADE TO PARKING LOT STABILIZED AREA FOR STAGING AREA ANDCONSTRUCTION TRAILERS.11. EARTHWORK AND EXCAVATION/FILLING AS NECESSARY TO ACHIEVE ROUGH PARKING ANDBUILDING PAD ELEVATIONS.12.CONSTRUCTION OF UTILITIES13.CONSTRUCTION AND STABILIZATION OF BUILDING PAD.14.CONSTRUCTION OF BUILDING15.CONTRACTOR AND OWNER SHALL COORDINATE WITH SWPPP MONITORING PROFESSIONAL TOENSURE PREVIOUSLY DISTURBED AREAS IN NORTH LOT ARE STABILIZED PRIOR TO ANY WORKCOMMENCING ON THE SOUTHERN SIDE OF THE PROJECT SITE.PHASE II16.AFTER COMPLETING THE NORTH LOT, WORK WILL CONTINUE COUNTER CLOCKWISE DOWN THEWEST PARKING LOT AND INTO THE SOUTH PARKING LOT AND AROUND THE EAST ROADINSTALLING STONE SUBGRADE STABILIZING AREA.17.REPEAT STEPS 7-12 AS NEEDED18.FOR THE POROUS PAVEMENT SECTIONS, SUBBASE WILL BE CONSTRUCTED WITH SELECTMATERIALS, INCLUDING THE BOTTOM RESERVOIR LAYER TO THE TOP OF THE FILTER COURSE,PLUS 2" OF ADDITIONAL FILTER COURSE MATERIAL AS OVERFILL. THIS SECTION IS SUITABLEFOR CONSTRUCTION TRAFFIC AND STOCKPILING OF SOIL MATERIALS AS NEEDED.19.WEEKLY VACUUMING OF STABILIZED ROADS, AT A MINIMUM, IS RECOMMENDED TO PREVENTTRACKING ONTO POROUS PAVEMENT.20.INSTALLATION OF POROUS PAVEMENT.--REMOVE 2" OF OVERFILL, REGRADE, COMPACT AND INSPECT PER POROUS PAVEMENTSPECIFICATIONS ON SUBBASE CONSTRUCTION--IF OVER-COMPACTION OF SUBBASE HAS OCCURED OR WHERE EROSION HAS CAUSEDACCUMULATION OF FINE MATERIALS, MATERIALS SHALL BE REMOVED AND/OR SCARIFIED TO AMINIMUM DEPTH OF 6" AND RETESTED FOR COMPACTION AND INFILTRATION PER SPECS.--INSTALL CHOKER COURSE AND BINDER COURSE PER DETAIL.--TEMPORARY CONSTRUCTION FENCING WILL BE USED TO CLOSE POROUS PAVEMENT AREASTO CONSTRUCTION TRAFFIC DURING PROJECT COMPLETION--EROSION CONTROLS AND/OR TEMPORARY GRADING WILL BE USED AS NEEDED TO PREVENTRUN-ON TO THE POROUS PAVEMENT--FINAL POROUS PAVEMENTS SHALL NOT BE PAVED UNTIL ADJACENT AREAS ARE STABILIZED.PHASE IIILAWN AREA WILL BE COMPLETED AFTER THE PARKING LOTS ARE STABILIZED, WORK SHALL BEPHASED TO STAY WITHIN 5 ACRE DISTURBANCE LIMIT.-CONSTRUCTION OF ALL CURBING AND LANDSCAPE ISLANDS AS INDICATED ON THE PLANS-SPREAD TOPSOIL ON SLOPED AREAS AND SEED AND MULCH-FINAL GRADING OF ALL SLOPED AREAS-PLACE 6" TOPSOIL ON SLOPES AFTER FINAL GRADING COMPLETED. FERTILIZE, SEED, AND MULCHSEED MIXTURE TO BE INSTALLED REQUIRED.-REMOVAL OF THE TEMPORARY SEDIMENT BASINS-PAVE PARKING LOT-LANDSCAPING PER LANDSCAPING PLAN-REMOVE EROSION CONTROLS AS DISTURBED AREAS BECOME STABILIZED TO 80% STABILIZATION ORGREATER.CONSTRUCTION SEQUENCEAREAS WHERE TOPSOIL ISSTRIPPED ONLY - NOCHANGE IN GRADEHSG A&B: APPLY 6" OF TOPSOILHSG C&D: AERATE AND APPLY 6" OF TOPSOILHSG A&B: AERATE AND APPLY 6" OF TOPSOILHSG C&D: APPLY FULL SOIL RESTORATION (SEE NOTES ON SHEETC-602)HEAVY TRAFFIC AREAS ON SITE(ESPECIALLY IN A ZONE 5-25 FEETAROUND BUILDINGS BUT NOTWITHIN 5 FOOT PERIMETERAROUND FOUNDATION WALLS)APPLY FULL SOIL RESTORATION (DE-COMPACTION ANDCOMPOST ENHANCEMENT, PER CURRENT VERSION OF NYS DECDEEP RIPPING AND DECOMPACTION)AREAS WHERE RUNOFFREDUCTION AND OR INFILTRATIONPRACTICES ARE APPLIEDRESTORATION NOT REQUIRED, BUT MAY BEAPPLIED TO ENHANCE THE REDUCTIONSPECIFIED FOR APPROPRIATE PRACTICES.SOIL RESTORATION IS REQUIRED ONREDEVELOPMENT PROJECTS IN AREAS WHEREEXISTING IMPERVIOUS AREA WILL BECONVERTED TO PERVIOUS AREA.TYPE OF DISTURBANCENO SOIL DISTURBANCEMINIMAL SOIL DISTURBANCEAREAS OF CUT OR FILLREDEVELOPMENTPROJECTSSOIL RESTORATION REQUIREMENTRESTORATION NOT PERMITTEDRESTORATION NOT REQUIREDSOIL RESTORATION REQUIREMENTSDISTURBED AREA AS PROPOSED SHALLNEVER EXCEED 5 ACRES IN SIZE ATANY GIVEN TIME.FINAL PHASING LIMITS TO BECOORDINATED WITH GC DURINGBUILDING PERMIT SUBMISSIONGC TO SEEK 5-ACRE WAIVER FROMNYSDEC IF 5 ACRES OR MORE OFDISTURBANCE IS TO OCCUR AT ONETIME. OTHERWISE, GC SHALL FOLLOWPHASED CONSTRUCTION AS NOTED ONTHIS PLAN. REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY12345678REVISION 8 -01/19/2024CLIENT COMMENTSSGSW02/02/2024CITY COMMENTSSGVR03/04/2024CITY COMMENTSSGSW03/20/2024CITY COMMENTSSGVR04/15/2024CITY AND TDECOMMENTSAKDSRW05/03/2024PRELIMINARY ISSUEFOR CONSTRUCTIONAKDSRW06/07/2024DOT AND SCSDCOMMENTSAKDSRW06/14/2024ADDENDUM 1AKDSRW06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORP:\2023\NYB230191.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\NYB230191.00-SPPD-0A----->LAYOUT: C-602 ENOTEAD THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191SAG/AKDSRW11/30/2023NYB230191.00-SPPD-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK 2 - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comEROSION AND SEDIMENT CONTROL NOTES1.ALL SEDIMENT AND EROSION CONTROL MEASURES SHALL BE DONE AS SET FORTH IN THE MOST CURRENT STATE SEDIMENT ANDEROSION CONTROL MANUAL.2.THOSE AREAS UNDERGOING ACTUAL CONSTRUCTION WILL BE LEFT IN AN UNTREATED OR UNVEGETATED CONDITION FOR AMINIMUM TIME. AREAS SHALL BE PERMANENTLY STABILIZED IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REQUIREMENTS.AT A MINIMUM, AREAS SHALL BE PERMANENTLY STABILIZED ACCORDING TO THE NEW YORK STATE STANDARDS ANDSPECIFICATIONS FOR EROSION AND SEDIMENT CONTROL (REFERRED TO AS THE "BLUE BOOK"), OR IN THE ABSENCE OF THE BLUEBOOK, THEY SHALL BE PERMANENTLY STABILIZED WITHIN 14 DAYS OF FINAL GRADING AND TEMPORARILY STABILIZED WITHIN 30DAYS OF INITIAL DISTURBANCE OF THE SOIL. IF THE DISTURBANCE IS WITHIN 100 FEET OF A STREAM OR POND, THE AREA SHALL BESTABILIZED WITHIN 7 DAYS OR PRIOR TO ANY STORM EVENT (THIS WOULD INCLUDE WETLANDS).3.SEDIMENT BARRIERS (SILT FENCE, STRAW BARRIERS, ETC.) SHOULD BE INSTALLED PRIOR TO ANY SOIL DISTURBANCE OF THECONTRIBUTING DRAINAGE AREA ABOVE THEM. MULCH NETTING SHALL BE USED TO ANCHOR MULCH IN ALL AREAS WITH SLOPESGREATER THAN 8%.4.INSTALL SILTATION BARRIER AT TOE OF SLOPE TO FILTER SILT FROM RUNOFF. SEE SILTATION BARRIER DETAILS FOR PROPERINSTALLATION. SILTATION BARRIER WILL REMAIN IN PLACE PER NOTE #5. THE FOLLOWING EROSION CONTROL MEASURES ARE PROPOSEDFOR THIS SITE SUCH AS:4.1.TEMPORARY SEDIMENT BASIN4.2.CHECK DAMS4.3.STABILIZED CONSTRUCTION ENTRANCE4.4.TEMPORARY STOCKPILE4.5.CONCRETE WASTE MANAGEMENT4.6.TEMPORARY SWALES5.ALL EROSION CONTROL STRUCTURES WILL BE INSPECTED, REPLACED AND/OR REPAIRED EVERY 7 DAYS AND IMMEDIATELYFOLLOWING ANY SIGNIFICANT RAINFALL OR SNOW MELT OR WHEN NO LONGER SERVICEABLE DUE TO SEDIMENT ACCUMULATIONOR DECOMPOSITION. SEDIMENT DEPOSITS SHOULD BE REMOVED AFTER EACH STORM EVENT. THEY MUST BE REMOVED WHENDEPOSITS REACH APPROXIMATELY ONE HALF THE HEIGHT OF THE BARRIER. SEDIMENT CONTROL DEVICES SHALL REMAIN IN PLACEAND BE MAINTAINED BY THE CONTRACTOR UNTIL AREAS UPSLOPE ARE PERMANENTLY STABILIZED. FOR SEDIMENT CONTROLDEVICES THAT ARE WITHIN AREAS SUBJECT TO CONSERVATION COMMISSION JURISDICTION, THE DEVICES SHALL REMAIN IN PLACEAND BE REMOVED IN ACCORDANCE WITH THE ORDER OF CONDITIONS.6.NO SLOPES, EITHER PERMANENT OR TEMPORARY, SHALL BE STEEPER THAN TWO TO ONE (2:1) UNLESS OTHERWISE INDICATED ONTHE PLANS. SLOPE PROTECTION FOR SLOPES GREATER THAN 2:1 SHALL BE DESIGNED BY A GEOTECHINCAL ENGINEER.7.IF FINAL SEEDING OF THE DISTURBED AREAS IS NOT COMPLETED 45 DAYS PRIOR TO THE FIRST KILLING FROST, USE TEMPORARYMULCH (DORMANT SEEDING MAY BE ATTEMPTED AS WELL) TO PROTECT THE SITE AND DELAY SEEDING UNTIL THE NEXTRECOMMENDED SEEDING PERIOD.8.TEMPORARY SEEDING OF DISTURBED AREAS THAT HAVE NOT BEEN FINAL GRADED SHALL BE COMPLETED 45 DAYS PRIOR TO THEFIRST KILLING FROST TO PROTECT FROM SPRING RUNOFF PROBLEMS.9.DURING THE CONSTRUCTION PHASE, INTERCEPTED SEDIMENT SHALL BE REMOVED AND DISPOSED OF IN ACCORDANCE WITHLOCAL, STATE, AND FEDERAL STANDARDS.10.REVEGETATION MEASURES WILL COMMENCE UPON COMPLETION OF CONSTRUCTION EXCEPT AS NOTED ABOVE. ALL DISTURBEDAREAS NOT OTHERWISE STABILIZED WILL BE GRADED, SMOOTHED, AND PREPARED FOR FINAL SEEDING AS FOLLOWS:10.1.SIX INCHES, OR DEPTH SPECIFIED ON THE LANDSCAPE PLAN, OF LOAM WILL BE SPREAD OVER DISTURBED AREAS ANDSMOOTHED TO A UNIFORM SURFACE.10.2.APPLY LIMESTONE AND FERTILIZER ACCORDING TO SOIL TEST. IF SOIL TESTING IS NOT FEASIBLE ON SMALL OR VARIABLESITES, OR WHERE TIMING IS CRITICAL, FERTILIZER MAY BE APPLIED AT THE RATE OF 800 LB PER ACRE OR 18.4 LB PER 1,000 SFUSING 10-20-20 OR EQUIVALENT. APPLY GROUND LIMESTONE (EQUIVALENT TO 50% CALCIUM PLUS MAGNESIUM OXIDE) AT ARATE OF 3 TONS PER ACRE (138 LB PER1,000 SF).10.3.FOLLOWING SEED BED PREPARATION, DITCHES AND BACK SLOPES WILL BE SEEDED TO A MIXTURE OF 47% CREEPING REDFESCUE, 5% REDTOP, AND 48% TALL FESCUE. THE LAWN AREAS WILL BE SEEDED TO A PREMIUM TURF MIXTURE OF 44%KENTUCKY BLUE-GRASS, 44% CREEPING RED FESCUE, AND 12% PERENNIAL RYEGRASS: SEEDING RATE IS 1.03 LBS PER 1,000SF LAWN. QUALITY SOD MAY BE SUBSTITUTED FOR SEED WHERE SLOPES DO NOT EXCEED 2:1, SOD ON SLOPES STEEPERTHAN 3:1 SHOULD BE PEGGED.10.4.STRAW MULCH AT THE RATE OF 70-90 LBS PER 1,000 SF. A HYDRO-APPLICATION OF WOOD OR PAPER FIBER SHALL BE APPLIEDFOLLOWING SEEDING. A SUITABLE NON-TOXIC BINDER WILL BE USED ON STRAW MULCH FOR WIND CONTROL.11.ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED ONCE THE SITE IS 70% STABILIZED. FOR EROSION CONTROLMEASURES THAT ARE WITHIN AREAS SUBJECT TO CONSERVATION COMMISSION JURISDICTION, THE MEASURES SHALL REMAIN INPLACE AND BE REMOVED IN ACCORDANCE WITH THE ORDER OF CONDITIONS.12.WETLANDS WILL BE PROTECTED WITH BARRIERS CONSISTING OF STRAW BALES, COMPOST TUBES, SILT FENCE OR A COMBINATIONTHEREOF.13.ALL AREAS WITHIN 100 FEET OF A FLAGGED WETLAND OR STREAM SHALL HAVE AN EXPOSURE WINDOW OF NOT MORE THAN 7 DAYS.14.ALL AREAS WITHIN 100 FEET OF A FLAGGED WETLAND OR STREAM SHALL FOLLOW APPROPRIATE EROSION CONTROL MEASURESPRIOR TO EACH STORM IF NOT BEING ACTIVELY WORKED:LOCATIONMULCHMULCH RATE (1000 SF)PROTECTED AREASTRAW100 POUNDSWINDY AREASHREDDED OR CHOPPED CORNSTALKS185-275 POUNDSSTRAW (ANCHORED)*100 POUNDSMODERATE TO HIGHJUTE MESH OR EXCELSIOR MATAS REQUIREDVELOCITY AREAS ORSTEEP SLOPES GREATERTHAN 3:1GREATER THAN 3:1 (REFER TO GEOTECHNICAL REPORT FOR FINAL DESIGN REQUIREMENT)* A HYDRO-APPLICATION OF WOOD OR PAPER FIBER MAY BE APPLIED FOLLOWING SEEDING. A SUITABLE NON-TOXIC BINDER SHALLBE USED TO ADDITIONAL WIND CONTROL.MULCH ANCHORING: ANCHOR MULCH WITH PEG AND TWINE (1 SQ. YD/BLOCK); MULCH NETTING (AS PER MANUFACTURER); WOODCELLULOSE FIBER (750 LBS/ACRE); CHEMICAL TACK (AS PER MANUFACTURER'S SPECIFICATIONS); USE OF A SERRATED STRAIGHTDISK. WETTING FOR SMALL AREAS AND ROAD DITCHES MAY BE PERMITTED.15.STOCKPILING OF MATERIALS (DIRT, WOOD, CONSTRUCTION MATERIALS, ETC.) MUST REMAIN COVERED AT ALL TIMES TO MINIMIZEANY DUST PROBLEMS THAT MAY OCCUR WITH ADJACENT PROPERTIES AND TO PROVIDE MAXIMUM PROTECTION AGAINST EROSIONRUNOFF.16.EXISTING CATCH BASIN STRUCTURES SHALL BE PROTECTED UNTIL SUCH TIME AS THEY ARE REMOVED.17.THE CONTRACTOR MUST PERFORM DEWATERING (IF REQUIRED), IN ACCORDANCE WITH STATE AND LOCAL REGULATIONS. IT IS THECONTRACTOR'S RESPONSIBIITY TO OBTAIN AND PAY FOR THE COSTS ASSOCIATED WITH ANY AND ALL NECESSARY DISCHARGEPERMITS ASSOCIATED WITH SAME.18.THE CONTRACTOR MUST LOCATE CONSTRUCTION WASTE MATERIAL STORAGE AREAS TO MINIMIZE EXPOSURE TO STORMWATER.THE CONTRACTOR MUST IMMEDIATEL PLACE CONSTRUCTION WASTE IN ON-SITE STORAGE CONTAINERS UNTIL THATCONSTRUCTION WASTE IS READY FOR OFF-SITE DISPOSAL. THE CONTRACTOR MUST MAINTAIN SPILL PREVENTION AND RESPONSEEQUIPMENT AND MAKE SAME CONTINUOUSY AVAILABLE ON-SITE FOR USE BY THE CONTRACTOR'S EMPLOYEES WHO MUST BEPROPERLY TRAINED IN THE APPLICATION OF SPILL PREVENTION AND RESPONSE PROCEDURES.19.EROSION CONTROL NOTES DURING WINTER CONSTRUCTION20.WINTER CONSTRUCTION PERIOD: NOVEMBER 1 THROUGH APRIL 15.21.WINTER EXCAVATION AND EARTHWORK SHALL BE DONE SUCH THAT THE AMOUNT OF AREA OPEN AT ONE TIME IS MINIMIZED TO THEMAXIMUM EXTENT PRACTICABLE AND IN CONFORMANCE WITH THE STORMWATER POLLUTION PREVENTION PLAN SUCH THATADEQUATE PROVISIONS ARE EMPLOYED TO CONTROL STORMWATER RUNOFF.22.CONTINUATION OF EARTHWORK OPERATION ON ADDITIONAL AREAS SHALL NOT BEGIN UNTIL THE EXPOSED SOIL SURFACE ON THEAREA BEING WORKED HAS BEEN STABILIZED SUCH THAT NO LARGER AREA OF THE SITE IS WITHOUT EROSION CONTROLPROTECTION AS LISTED IN ITEM 2 ABOVE.23.AN AREA SHALL BE CONSIDERED TO HAVE BEEN TEMPORARILY STABILIZED WHEN EXPOSED SURFACES HAVE BEEN EITHERMULCHED WITH STRAW OR STRAW AT A RATE OF 100 LB. PER 1,000 SQUARE FEET (WITH OR WITHOUT SEEDING) OR DORMANTSEEDED, MULCHED AND ADEQUATELY ANCHORED BY AN APPROVED ANCHORING TECHNIQUE.24.FOR AREAS WHERE CONSTRUCTION ACTIVITIES HAVE CEASED FOR A PERIOD EXCEEDING 14 DAYS BETWEEN THE DATES OFNOVEMBER 1ST AND APRIL 1ST, LOAM OR SEED WILL NOT BE REQUIRED. THE SLOPES SHALL BE FINE GRADED AND EITHERPROTECTED WITH MULCH OR TEMPORARILY SEEDED. IF THE EXPOSED AREA HAS BEEN LOAMED, FINAL GRADED AND IS SMOOTH,THEN THE AREA MAY BE DORMANT SEEDED AT A RATE OF 200-300% HIGHER THAN SPECIFIED FOR PERMANENT SEED AND THENMULCHED AS APPLICABLE. SLOPES SHALL NOT BE LEFT UNSTABILIZED OVER THE WINTER OR IN AREAS WHERE WORK HAS CEASEDFOR MORE THAN 14 DAYS UNLESS TREATED IN THE ABOVE MANNER. UNTIL SUCH TIME AS WEATHER CONDITIONS ALLOW DITCHESTO BE FINISHED WITH THE PERMANENT SURFACE TREATMENT, EROSION SHALL BE CONTROLLED BY THE INSTALLATION OFSEDIMENT BARRIERS OR STONE CHECK DAMS IN ACCORDANCE WITH THE STANDARD DETAILS.25.MULCHING REQUIREMENTS:25.1.BETWEEN THE DATES OF NOVEMBER 1ST AND APRIL 15TH ALL MULCH SHALL BE ANCHORED BY EITHER PEG LINE, MULCHNETTING OR WOOD CELLULOSE FIBER.25.2.MULCH NETTING SHALL BE USED TO ANCHOR MULCH IN ALL DRAINAGE WAYS WITH A SLOPE GREATER THAN 3% FOR SLOPEEXPOSED TO DIRECT WINDS AND FOR ALL OTHER SLOPES GREATER THAN 8%.25.3.MULCH NETTING SHALL BE USED TO ANCHOR MULCH IN ALL AREAS WITH SLOPES GREATER THAN 15%. AFTER OCTOBER 1STTHE SAME APPLIES FOR ALL SLOPES GREATER THAN 8%.26.ALL DISTURBED AREAS SHALL BE STABILIZED IN ACCORDANCE WITH THE STORMWATER PREVENTION PLAN.27.DURING THE WINTER CONSTRUCTION PERIOD ALL SNOW SHALL BE REMOVED FROM AREAS OF SEEDING AND MULCHING PRIOR TOPLACEMENT.GENERAL EROSION AND SEDIMENT CONTROL NOTES1.THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THE GENERALNOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THECONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES.2.EROSION CONTROL MEASURES MUST CONFORM TO THE STATE, LOCAL, AND FEDERAL GUIDELINES FOR URBAN EROSION AND SEDIMENT CONTROL UNLESSOTHERWISE NOTED, OR UNLESS THE PROFESSIONAL OF RECORD CLEARLY AND SPECIFICALLY, IN WRITING, DIRECTS OTHERWISE. INSTALLATION OF EROSIONCONTROL, CLEARING, AND SITE WORK MUST BE PERFORMED EXACTLY AS INDICATED IN THE EROSION CONTROL CONSTRUCTION NOTES.3.THE DISTURBED LAND AREA OF THIS SITE IS APPROXIMATELY ±9.87 ACRES.4.THE FOLLOWING EROSION CONTROL MEASURES ARE PROPOSED FOR THIS SITE:A.STABILIZED CONSTRUCTION ENTRANCE/ EXIT - A TEMPORARY GRAVEL CONSTRUCTION ENTRANCE/EXIT IS TO BE INSTALLED AT THE DESIGNATEDLOCATION SHOWN ON THE PLAN. THIS AREA MUST BE GRADED SO THAT RUNOFF WATER WILL BE RETAINED ON-SITE.B.SEDIMENT FENCE - INSTALL SILT FENCE(S) AND/OR SILT SOCK AROUND ALL OF THE DOWNSLOPE PERIMETERS OF THE SITE, TEMPORARY FILL AND SOILSTOCKPILES.C.INSTALL FILTER FABRIC DROP INLET PROTECTION AROUND EACH DRAINAGE INLET AS DRAINAGE STRUCTURES ARE INSTALLED TO REDUCE THE QUANTITYOF SEDIMENT. INSTALL TEMPORARY INLET PROTECTION ON INLETS DOWNSLOPE FROM DISTURBANCE, WHICH MAY BE BEYOND THE LIMITS OF DISTURBEDAREA.5.INSTALLATION OF EROSION CONTROL DEVICES MUST BE IN ACCORDANCE WITH ALL OF THE MANUFACTURER'S RECOMMENDATIONS.6.THE CONTRACTOR MUST INSPECT EROSION CONTROL MEASURES WEEKLY. THE CONTRACTOR MUST REMOVE ANY SILT DEPOSITS GREATER THAN 6 INCHESOR HALF THE EROSION CONTROL BARRIER'S HEIGHT COLLECTED ON THE FILTER FABRIC AND/OR SILT SOCK BARRIERS AND EXCAVATE AND REMOVE ANYSILT FROM DROP INLET PROTECTION.7.THE CONTRACTOR MUST APPLY TEMPORARY SEED AND MULCH TO ALL DISTURBED AREAS THAT WILL NOT BE BROUGHT TO FINISHED GRADE ANDVEGETATED WITHIN 7 DAYS. WHEN AREAS ARE DISTURBED AFTER THE GROWING SEASON, THE CONTRACTOR MUST STABILIZE SAME WITH GEOTEXTILEFABRIC AND MAINTAIN SAME IN STRICT ACCORDANCE WITH BEST MANAGEMENT PRACTICES.8.THE CONTRACTOR MUST INSTALL ADDITIONAL EROSION CONTROL MEASURES IF THE PROFESSIONAL OF RECORD SO REQUIRES, TO PREVENT ANY,INCLUDING THE INCIDENTAL, DISCHARGE OF SILT-LADEN RUNOFF FROM EXITING THE SITE.9.THE CONTRACTOR MUST BE RESPONSIBLE FOR INSPECTING AND MAINTAINING ALL EROSION CONTROL MEASURES ON THE SITE UNTIL PERMANENT PAVINGAND TURF/LANDSCAPING IS ESTABLISHED. THE COSTS OF INSTALLING AND MAINTAINING THE EROSION CONTROL MEASURES MUST BE INCLUDED IN THEBID PRICE FOR THE SITE WORK AND THE CONTRACTOR IS RESPONSIBLE FOR ALL SUCH COSTS.10.THE CONTRACTOR MUST CONTINUE TO MAINTAIN ALL EROSION CONTROL MEASURES UNTIL THE COMPLETION OF CONSTRUCTION AND THEESTABLISHMENT OF VEGETATION.11.THE CONTRACTOR MUST REMOVE EROSION CONTROL MEASURES, SILT AND DEBRIS AFTER ESTABLISHING PERMANENT VEGETATION COVER OR OTHERINSTALLING A DIFFERENT, SPECIFIED METHOD OF STABILIZATION.12.THIS PLAN REPRESENTS THE MINIMUM LEVEL OF IMPLEMENTATION OF TEMPORARY EROSION AND SEDIMENTATION CONTROL FACILITIES, MEASURES ANDSTRUCTURES. ADDITIONAL FACILITIES, MEASURES AND STRUCTURES MUST BE INSTALLED WHERE NECESSARY TO COMPLY WITH ALL APPLICABLE CODESAND STANDARDS AND/OR TO PREVENT ANY, INCLUDING THE INCIDENTAL DISCHARGE OF SILT-LADEN RUNOFF FROM EXITING THE SITE.13.THE CONTRACTOR MUST PROTECT ALL EXISTING TREES AND SHRUBS. THE CONTRACTOR MUST REFER TO THE LANDSCAPE AND/OR DEMOLITION PLAN(S)FOR TREE PROTECTION, FENCE LOCATIONS AND DETAILS.14.THE CONTRACTOR MUST REFER TO GRADING PLANS FOR ADDITIONAL INFORMATION.15.THE CONTRACTOR MUST CLEAN EXISTING AND PROPOSED DRAINAGE STRUCTURES AND INTERCONNECTING PIPES ON OR OFF-SITE AS THE JURISDICTIONALAGENCY REQUIRES, BOTH AT THE TIME OF SITE STABILIZATION AND AT END OF PROJECT.16.SOIL EROSION CONTROL MEASURES MUST BE ADJUSTED OR RELOCATED BY THE CONTRACTOR AS IDENTIFIED DURING SITE OBSERVATION IN ORDER TOMAINTAIN THE COMPLETE EFFECTIVENESS OF ALL CONTROL MEASURES.17.THE CONTRACTOR MUST IDENTIFY, ON THE PLAN, THE LOCATION OF WASTE CONTAINERS, FUEL STORAGE TANKS, CONCRETE WASHOUT AREAS AND ANYOTHER LOCATIONS WHERE HAZARDOUS MATERIALS ARE STORED.SOIL RESTORATION PROCEDURE, PER NYSDEC "BLUE BOOK":DURING PERIODS OF RELATIVELY LOW TO MODERATE SUBSOIL MOISTURE, THE DISTURBED SUBSOILS ARE RETURNED TO ROUGHGRADE AND THE FOLLOWING SOIL RESTORATION STEPS APPLIED:1.APPLY 3 INCHES OF COMPOST OVER SUBSOIL.2.TILL COMPOST INTO SUBSOIL TO A DEPTH OF AT LEAST 12 INCHES USING A CAT-MOUNTED RIPPER, TRACTOR-MOUNTED DISC, ORTILLER, MIXING, AND CIRCULATING AIR AND COMPOST INTO SUBSOILS.3.ROCK-PICK UNTIL UPLIFTED STONE/ROCK MATERIALS OF FOUR INCHES AND LARGER SIZE ARE CLEANED OFF THE SITE.4.APPLY TOPSOIL TO A DEPTH OF 6 INCHES.5.VEGETATE AS REQUIRED BY APPROVED PLAN.AT THE END OF THE PROJECT AN INSPECTOR SHOULD BE ABLE TO PUSH A 3/8” METAL BAR 12 INCHES INTO THE SOIL JUST WITH BODYWEIGHT. TILLING (STEP 2 ABOVE) SHOULD NOT BE PERFORMED WITHIN THE DRIP LINE OF ANY EXISTING TREES OR OVER UTILITYINSTALLATIONS THAT ARE WITHIN 24 INCHES OF THE SURFACE.COMPOST SPECIFICATIONS:COMPOST SHALL BE AGED, FROM PLANT DERIVED MATERIALS, FREE OF VIABLE WEED SEEDS, HAVE NO VISIBLE FREE WATER OR DUSTPRODUCED WHEN HANDLING, PASS THROUGH A HALF INCH SCREEN AND HAVE A PH SUITABLE TO GROW DESIRED PLANTS WITH NOOBJECTIONABLE ODORS.MAINTENANCE:A SIMPLE MAINTENANCE AGREEMENT SHOULD IDENTIFY WHERE SOIL RESTORATION IS APPLIED, WHERE NEWLY RESTORED AREASARE/CANNOT BE CLEARED, WHO THE RESPONSIBLE PARTIES ARE TO ENSURE THAT ROUTINE VEGETATION IMPROVEMENTS ARE MADE(I.E., THINNING, INVASIVE PLANT REMOVAL, ETC.). SOIL COMPOST AMENDMENTS WITHIN A FILTER STRIP OR GRASS CHANNEL SHOULDBE LOCATED IN PUBLIC RIGHT OF WAY, OR WITHIN A DEDICATED STORMWATER OR DRAINAGE EASEMENT.FIRST YEAR MAINTENANCE OPERATIONS INCLUDES:·INITIAL INSPECTIONS FOR THE FIRST SIX MONTHS (ONCE AFTER EACH STORM GREATER THAN HALF-INCH).·RESEEDING TO REPAIR BARE OR ERODING AREAS TO ASSURE GRASS STABILIZATION·WATER ONCE EVERY THREE DAYS FOR FIRST MONTH, AND THEN PROVIDE A HALF INCH OF WATER PER WEEK DURING FIRSTYEAR. IRRIGATION PLAN MAY BE ADJUSTED ACCORDING TO THE RAIN EVENT.·FERTILIZATION MAY BE NEEDED IN THE FALL AFTER THE FIRST GROWING SEASON TO INCREASE PLANT VIGOR.ONGOING MAINTENANCE:TWO POINTS HELP ENSURE LASTING RESULTS OF DECOMPACTION:1.PLANTING THE APPROPRIATE GROUND COVER WITH DEEP ROOTS TO MAINTAIN SOIL STRUCTURE.2.KEEPING THE SITE FREE OF VEHICULAR AND FOOT TRAFFIC OR OTHER WEIGHT LOADS. CONSIDER PEDESTRIAN FOOTPATHS.(SOMETIMES IT MAY BE NECESSARY TO DE-THATCH THE TURF EVERY FEW YEARS).NOTES:1.TEMPORARY CONCRETE WASHOUT FACILITIESSHOULD BE LOCATED A MINIMUM OF 50 FT. FROMSTORM DRAIN INLETS.2.ONCE CONCRETE WASTES ARE WASHED INTO THEDESIGNATED AREA AND ALLOWED TO HARDEN, THECONCRETE SHOULD BE BROKEN UP, REMOVED, ANDDISPOSED OF OFF-SITE. CONTRACTOR TO DISPOSEOF HARDENED CONCRETE ON A REGULAR BASIS.3.THE CONCRETE WASHOUT SIGN SHALL BE INSTALLEDWITHIN 30 FT. OF THE TEMPORARY CONCRETEWASHOUT FACILITY.4.PLASTIC LINING MATERIAL SHOULD BE A MINIMUM OF10 MIL POLYETHYLENE SHEETING AND SHOULD BEFREE OF HOLES, TEARS, OR OTHER DEFECTS THATCOMPROMISE THE IMPERMEABILITY OF THEMATERIAL.5.WASHOUT FACILITIES MUST BE CLEANED, OR NEWFACILITIES MUST BE CONSTRUCTED AND READY FORUSE ONCE THE WASHOUT IS 75% FULL.6.STRAW BALE AND STAPLES MAY BE SUBSTITUTEDWITH ALTERNATE SECURING MEASURES SUCH ASCONCRETE BLOCK.ACONCRETE WASHOUT SIGN DETAIL (OR EQUIVALENT)SECTION A-ASTAPLE DETAILPLANCONCRETEWASHOUT10'(MIN.)VARIES 3'3' 4"2"ASTAPLES2 PER BALE)10 MIL PLASTICLININGBINDING WIRESTRAW BALE(SEE NOTE 6)NATIVE MATERIAL(OPTIONAL)WOOD OR METALSTAKES (2 PER BALE)1/8" DIA. STEEL WIREWOOD POST 3" X 3" X 8'0.5" LAG SCREWSBLACK LETTERSPLYWOOD 48" X 24"PAINTED WHITESTAKE (TYP.)10 MIL PLASTIC LININGSTRAW BALE (TYP.)CONCRETE WASTE MANAGEMENT DETAILTYP. SILTATION FENCETOE-IN METHODSPERSPECTIVE OF FENCEFLOW(PRE-ASSEMBLED PRIOR TO INSTALLATION)DETAIL OF POST ATTACHMENTBACKFILLSILT FENCE (3' WIDE)FABRICPOSTBACKFILLFILTERFABRICSLATPOSTPOSTFILTERFABRICSLATBACKFILL6"MIN.LAPNATIVE SOIL1-1/2" x 1-1/2" POSTFABRICWOOD OR PLASTIC SLAT STAPLEDTHROUGH FABRIC TO POST24" MIN.12" MIN.(12" MAX.IN ROCKYSOIL.)NOTES:1.EXCAVATE A 6"x6" TRENCH ALONG THELINE OF EROSION CONTROL OF THESITE.2.UNROLL SILTATION FENCE AND POSITIONTHE POSTS AGAINST THE BACK(DOWNSTREAM) WALL OF THE TRENCH(NET SIDE AWAY FROM FLOWDIRECTION).3.DRIVE THE POST INTO THE GROUNDUNTIL THE NETTING IS LAYING ACROSSTHE TRENCH BOTTOM.4.LAY THE TOE-IN FLAP OF THE FABRICONTO THE UNDISTURBED BOTTOM OFTHE TRENCH, BACKFILL ALSO BEACCOMPLISHED BY LAYING FABRIC FLAPON UNDISTURBED GROUND AND PILING& TAMPING FILL AT THE BASE.STABILIZED CONSTRUCTION ENTRANCEPLAN VIEWPROFILEPERCENT SLOPE OF ROADWAY0 TO 2%2% TO 5%>5%LENGTH OF STONE REQUIREDCOARSE GRAINED SOILSFINE GRAINED SOILS50 FT100 FTENTIRE ENTRANCE STABILIZED WITH FABC BASE COURSE (1)(1) AS PRESCRIBED BY LOCAL ORDINANCE OR OTHER GOVERNING AUTHORITY.100 FT200FTCHART 1PROVIDE APPROPRIATETRANSITION BETWEEN STABILIZEDCONSTRUCTION ENTRANCE ANDPUBLIC R.O.W.25'R25'RSEE CHART 16" MIN.SEE CHART 1PUBLICR.O.W.EXISTING GROUND2-1/2" CLEAN STONEEXISTINGGROUNDPUBLICRIGHT OFWAYN.T.S.1335' MAXIMUMTEMPORARY STOCKPILE1:3 MAXIMUM SLOPECONSTRUCT SILT FENCE AROUND PERIMETER OF STOCKPILEN.T.S.N.T.S.N.T.S.N.T.S.N.T.S.C-602SOIL EROSION SEDIMENTCONTROL NOTE & DETAILSN.T.S.2 ACRES OR LESS OF DRAINAGE AREA(DOWNSTREAM VIEW)2Z=%WATER FLOW(DOWNSTREAM VIEW)2-10 ACRES OF DRAINAGE AREAAABBELEVATION AELEVATION BNOTE: SEE SITE MAP FOR LOCATION OFCHECK DAM(S).1212121CHECK DAMS IN SWALEFLOWHHHH6"6"6"6"HDROCK CHECK DAMTOP OF BANKFLOW LINEGENERAL RULE FOR SPACING:THE ELEVATION OF THE BOTTOM OF THE UPSTREAMBERM SHOULD BE EQUAL TO THE ELEVATION OFTHE TOP OF THE SUCCEEDING DOWNSTREAM BERM.GEOTEXTILE FABRIC(CEC TO SPECIFY)GEOTEXTILE FABRIC(CEC TO SPECIFY)TOP OF BANK2"-3" CLEAN STONERIPRAPTOP OF BANK2"-3" CLEAN STONESTONE OUTLET SEDIMENT BASIN DETAILSEE CALCULATIONS ABOVE1' MAX.5' MAX.1' MIN.1' MIN.11SMALL RIPRAPWEIR CRESTFILTER CLOTHEXCAVATE FOR REQUIRED STORAGE2" STONEOPTIONAL1221CROSS SECTIONAREA UNDER EMBANKMENT SHALL BE CLEARED, GRUBBED AND STRIPPED OF ANY VEGETATION AND ROOT MAT. THE POOL AREA SHALL BE CLEARED.THE FILL MATERIAL FOR THE EMBANKMENT SHALL BE FREE OF ROOTS AND OTHER WOODY VEGETATION AS WELL AS OVER-SIZED STONES, ROCKS, ORGANIC MATERIAL OR OTHER OBJECTIONABLE MATERIAL. THE EMBANKMENT SHALL BE COMPACT BY TRAVERSING WITH EQUIPMENT WHILE IT IS BEING CONSTRUCTED.ALL CUT AND FILL SLOPES SHALL BE 2:1 OR FLATTER.THE STONE USED IN THE OUTLET SHALL BE SMALL RIPRAP 4"-8" ALONG WITH A 1' THICKNESS OF 2" AGGREGATE PLACED ON THE UP-GRADE SIDE ON THE SMALL RIPRAP OR EMBEDDED FILTER CLOTH IN THE RIPRAP.SEDIMENT SHALL BE REMOVED AND TRAP RESTORED TO IT'S ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO 1/2 THE DESIGN DEPTH TO THE TRAP.THE STRUCTURE SHALL BE INSPECTED AFTER EACH RAIN AND REPAIRS MADE AS NEEDED.CONSTRUCTION OPERATIONS SHALL BE CARRIED OUT IN SUCH A MANNER THAT EROSION AND WATER POLLUTION IN MINIMIZED.THE STRUCTURE SHALL BE REMOVED AND THE AREA STABILIZED WHEN THE DRAINAGE AREA HAS BEEN PROPERLY STABILIZED.1.2.3.4.5.6.7.8.NOTES:4' MIN.L=4 X DRAINAGE AREA2' APRONOPTION: A ONE FOOT LAYER OF 2" STONE MAY BE PLACED ON THE UPSTREAM SIDE OF THE RIPRAP IN PLACE OF THE EMBEDDED FILTER CLOTH.TEMPORARY SWALE UNDISTURBED STABILIZED AREA AT NON-EROSIVE VELOCITY.CONSTRUCTION SPECIFICATIONS AS REQUIRED TO MEET THE CRITERIA SPECIFIED HEREIN AND BE FREE OF BANK4. ALL TREES, BRUSH, STUMPS, OBSTRUCTIONS, AND OTHER OBJECTIONABLE MATERIAL5. THE SWALE SHALL BE EXCAVATED OR SHAPED TO LINE, GRADE, AND CROSS SECTION SHALL BE REMOVED AND DISPOSED OF SO AS NOT TO INTERFERE WITH THE PROPER TRAPPING DEVICE.2. DIVERTED RUNOFF FROM A DISTURBED AREA SHALL BE CONVEYED TO A SEDIMENT1. ALL TEMPORARY SWALES SHALL HAVE UNINTERRUPTED POSITIVE GRADE TO AN OUTLET.6. FILLS SHALL BE COMPACTED BY EARTH MOVING EQUIPMENT.3. DIVERTED RUNOFF FROM AN UNDISTURBED AREA SHALL OUTLET DIRECTLY INTO ANEXISTING GROUNDC MIN.STORAGE AREACROSS SECTIOND MIN. LEVELSLOPE 2:1 OR FLATTERSLOPE 2:1 ORFLATTERSWALE A SWALE BC 1' 1'D 4' 6' FUNCTIONING OF THE SWALE. PROJECTIONS OR OTHER IRREGULARITIES WHICH WILL IMPEDE NORMAL FLOW.7. ALL EARTH REMOVED AND NOT NEEDED FOR CONSTRUCTION SHALL BE PLACED SO THAT IT WILL NOT INTERFERE WITH THE FUNCTIONING OF THE SWALE.8. STABILIZATION SHALL BE AS PER THE FLOW CHANNEL STABILIZATION CHART BELOW:9. PERIODIC INSPECTION AND REQUIRED MAINTENANCE MUST BE PROVIDED AFTER EACH RAIN EVENT.PLAN VIEWPOSITIVE DRAINAGE: 0.5% OR STEEPER DEPENDENT ON TOPOGRAPHYOUTLET AS REQUIRED SEEITEM 8 BELOW.TYPE OF CHANNELTREATMENT GRADE A(5 AC. OR LESS) B(5 AC -10AC) .1 0.5-3.0% SEED AND STRAW MULCH SEED AND STRAW MULCH2 3.1-5.0% SEED AND STRAW MULCH SEED AND COVER USING RECP3 5.1-8.0% SEED AND COVER WITH RECP GEOTEXTILE4 8.1-20.% LINED WITH 4-8" RIP-RAP OR GEOTEXTILELINED WITH 4-8" RIP-RAP OR..ENGINEERED DESIGNTO ORIGINAL DIMENSIONS WHEN 0.95' OF SEDIMENT HAS ACCUMULATEDORIGINAL ELEVATION TO BE MARKED AND TRAP TO BE RESTOREDAT ELEVATION 302.95SEDIMENT TRAP WILL REACH 1/2 DESIGN CAPACITYDESIGN CAPACITY= 19,885 CF x 0.5= 9,943 CFORIGINAL DESIGN CAPACITYSEDIMENT HAS ACCUMULATED TO 1/2 THERESTORED TO ORIGINAL DIMENSIONS WHENSEDIMENT SHALL BE REMOVED AND TRAPREQUIRED:PROVIDED: 19,885+/- CF 5(3,600)= 18,000 CFCONTRIBUTING DRAINAGE AREA=REQUIRED STORAGE= 3,600 CF PER ACRE OFPROVIDED: 4'x20' OUTLETMINIMUM WIDTH= 4'= 4 x 5= 20'REQUIRED LENGTH OF OUTLET= 4(DRAINAGE AREA)CONTRIBUTING AREA= ±5.0 ACRESSEDIMENT BASIN 1SEDIMENT BASIN #1CALCULATION REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY12345678REVISION 8 -01/19/2024CLIENT COMMENTSSGSW02/02/2024CITY COMMENTSSGVR03/04/2024CITY COMMENTSSGSW03/20/2024CITY COMMENTSSGVR04/15/2024CITY AND TDECOMMENTSAKDSRW05/03/2024PRELIMINARY ISSUEFOR CONSTRUCTIONAKDSRW06/07/2024DOT AND SCSDCOMMENTSAKDSRW06/14/2024ADDENDUM 1AKDSRW06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORP:\2023\NYB230191.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\NYB230191.00-SPPD-0A----->LAYOUT: C-901 DETLAD THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191SAG/AKDSRW11/30/2023NYB230191.00-SPPD-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK 2 - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comC-901DETAILSHEETTYP. PRECAST CONCRETEMANHOLE STORM DRAINTRANSITION CURB DETAILSLOPED WALK DETAILACCESSIBLE STALL MARKINGS &PARKING LOT STRIPING DETAIL'STOP' BAR DETAIL"DO NOT ENTER" SIGN2% MAX.1:12 (8 .3% )SLOPE MAX .1:12 (8.3%)SLOPE MAX.PROPOSED BUILDING(FOR SIDEWALK SLOPES LESS THAN 1:20 (5.0%) MAX.)NOTE: SLOPES OF ACCESSIBLE PARKING SPACES AND PARKING ACCESSAISLES SHALL NOT EXCEED 1:50 (2.0%) MAX. IN ANY DIRECTION.5'-0"MIN.FULL HEIGHT OF CURB30"R1-1 SIGNRED BKGND30"84" ABOVE GROUND 1/4" x 1/2" LG. PIN HD. BOLTSWITH NUTS & LOCKWASHERS11" MAX.3' OR 4'8"2'-0"TOPATFLOW12" COMPACTED GRAVELCOMBINATION OF 1, 2,3, OR 4' SECTIONSNOTE:ALL STRUCTURES SHALL BE SUITABLE FOR H-20 LOADING AND SHALL MEETTHE REQUIREMENTS OF ASTM C478.CURB TRANSITION- SEE SITE PLAN FOR LENGTHFLUSH TO FULL HEIGHT OF CURB24" DIA. HEAVY DUTY FRAME & COVERRIM ELEV.(SEE PLAN) (LABEL "DRAIN")FINISH GRADEMORTAR ALL AROUNDTWO COURSES OF BRICK MASONRYMINIMUM, FOUR MAXIMUM BEDFRAME AND BRICK WORK IN 3/8" MIN.FULL MORTAR BED.PRECAST REINFORCED 6" THICKCONCRETE CONE OR FLAT 8"THICK LID (WHERE BURIAL ISSHALLOW).ALUMINUM OR PLASTICCOATED WROUGHT IRONSTEPS @ 16"O.C.BUTYL RUBBERSEALANT (TYP.)PRECAST REINFORCEDCONCRETE RISERSECT.'S AS REQUIREDNON-SHRINK MORTAR @ PIPEOPENINGS ALL AROUNDCOMPACTEDSUBGRADE2500 PSI CONC. INVERT TO BEPOURED WHEN MANHOLE ISCOMPLETED5",7",OR9-3/4"(VARIESPER I.D.)4'-0", 6'-0" OR8'-0" (SEE PLAN)'STOP' SIGNACCESSIBLE PARKING SIGN DETAILPROPOSED CONCRETE LANDINGTO BE FLUSH WITH GRADEPROPOSED CONCRETESIDEWALKPROPOSED FACEOF CURB/WALKPROPOSED FACEOF CURB/WALK5'-0" MIN.6"6'-0" MIN.5'-0" M IN .VARIES (SEE S ITE PLAN)6'-0" M IN .WHITE BACKGROUNDRED CIRCLEWHITE BARWHITE LETTERSR5-1 SIGN1/4" x 1/2" LG. PIN HD. BOLTSWITH NUTS & LOCK WASHERS30"30"7'-0" ABOVE GROUND4" WIDE WHITESTRIPING (TYP.)18'-0"8'-0"8'-0"8'-0"5'-4"PAINTED (4" AZURE BLUE)ACCESSIBLE SYMBOL (SEEACCESSIBLE PARKINGSTALL PAINTING DETAIL)6'-4 1/2"4" WIDE AZUREBLUE STRIPING(TYP.)"ACCESSIBLE PARKING ONLY"SIGN (IN ACCORDANCE WITHADA GUIDE LINES - SEEACCESSIBLE PARKING SIGNDETAIL)6" TRANSITION CURB (TYP.)NOTE: ALL PAVEMENTSTRIPING AND MARKINGSSHALL CONSIST OFCHLORINATED RUBBERPAINT APPLIED TO A DRYSURFACE WHEN THETEMPERATURE IS GREATERTHAN 40°F. PAINT SHALL BEAPPLIED AT A MINIMUM OF0.015" (15 MIL) FILMTHICKNESSACCESSIBLE PARKINGSTALL PAINTING DETAIL12'1.0'12"24" MIN.8' MIN.6"TYP.DOUBLE WHITE LINE(SEE SITE PLAN)NOTE:ALL PAVEMENT STRIPING AND MARKINGSSHALL CONSIST OF CHLORINATED RUBBERPAINT APPLIED TO A DRY SURFACE WHENTHE TEMPERATURE IS GREATER THAN40°F. PAINT SHALL BE APPLIED AT AMINIMUM OF 0.015" (15 MIL) FILM THICKNESS10' MIN. (SEE PLAN)WHITE PAINT(SEE SPEC BELOW)NOTE: LOCATIONOF STOP SIGNSHALL BE IN LINEWITH STOP BAR6"6" (MIN.)N.T.S.N.T.S.N.T.S.N.T.S.N.T.S.40"± 9" R 12" RNOTE: WHEELCHAIR SYMBOL PAINTSHALL CONFORM TO THE STRIPINGPAINT SPECIFIED AND SYMBOL SHALLBE CENTERED IN THE STALL.BLUE REFLECTIVEPAINT WHERE PAINTEDON PARKING SPACESYRACUSE CASTING #4155 OR OPW 104-A OREQUAL FRAME AND COVER INSTALLED FLUSHTO GRADE (MARKED STORM)FLOW6" HDPE1/8 TH BEND4" CRUSHED STONE BASE6" HDPE& PLUG6" C.O. ADAPTER SECTIONVALVE BOX-TOP10"FINISHED GRADECLEANOUT DETAIL3'x3' CONC. COLLAR AROUND CLEANOUT14"BOLLARD DETAILTOP OF SLAB BITUMINOUS JOINT6" DIAMETER STEEL PIPEFILLED w/ CONC. PAINTEDBLACK AND EMBEDDEDIN CONC. BASEPROPER WATER RUN OFFCONCRETE TO BE RAISED FOR4'-0"3300 PSI CONCRETEPIPE AROUNDOR ASPHALT(8" DIA. STEEL PIPE WHERE INDICATED)3'-0"1'-0"1'-6"CLEANOUT FRAME TO BE MINIMUM H-20 LOADING RATED. MONOLITHIC CONC. SIDEWALK DETAILSEXPANSION JOINTxxxxCONTROL JOINTxxxxEND SECTIONxxxxUSE CHAIRS TO SUPPORT REINFORCING STEEL DURING POUR.TO BE USED FOR BUILDING SURROUND AND OTHER CONCRETE WALKS.4. PROVIDE EXPANSION JOINTS 20'- 0" O.C. MIN.3. PROVIDE CONTROL JOINTS 5'- 0" O.C. MIN.2. PROVIDE MINIMUM 1/8"/FT. CROSS-SLOPE1. SEE SITE PLAN FOR WIDE AND GRADESNOTES: 5"6" 5"6" 5"6" 12" 18"6"COMPACTED SUBGRADECOMPACTED GRAVEL BASE4,000 PSI AIR ENTRAINED CONC. (BROOM FINISH)6"x6"xW2.9x2.9 WWF1/8" RADIUS (TYP.)6"x6"xW2.9x2.9 WWF4,000 PSI AIRENTRAINED CONC.(BROOM FINISH)COMPACTEDGRAVEL BASECOMPACTEDSUBGRADEPREFORMED JOINT FILLERSEALER1/8" RADIUS (TYP.)1/2"1/2"1/8"1"FINISHED GRADES VARIESSEE PLANGC TO REFER TO GEOTECHNICAL REPORTPREPARED TERRACON CONSULTANTS, INC.DATED 02/08/13FOR PAVEMENTSPECIFICATIONS.60" ABOVE GROUND 1'-0"WITH NUTS & LOCK WASHERS1/4" x 1/2" LG. PIN HD. BOLTSAZURE BLUEGREEN LETTERSWHITE BACKGROUNDDIA.REFER TO ARCH PLANS BY OTHERS3000 PSI CONCRETE FOOTING#6 REBAR x 1'2" LONGEACH WAY THRU PIPE4'-0"18"2"3'-8"NOTE: ALL LETTER ANDSYMBOL SIZES SHALL BE INACCORDANCE WITH THELATEST EDITION OF ANSI A 117.11'-6" 60" ABOVE GROUND 1'-6"1'-0"WITH NUTS & LOCK WASHERS1/4" x 1/2" LG. PIN HD. BOLTSRED LEGENDWHITE BACKGROUND18"DIA.3'-8" 2" 4'-0"3000 PSI CONCRETE FOOTING#6 REBAR x 1'2" LONGEACH WAY THRU PIPEREFER TO ARCH PLANS BY OTHERSTYPICAL PAVEMENT MARKING DETAIL3'-4"1'-11"6'-7"9'-4"4'-4"10"1'-5"3'-8"3'-1"2'-8"4'-4"R1'-8"1'-3"WHITE(AREA 12.0 SQ.FT.)PAVEMENT MARKING, ARROW, TYPE 1PAVEMENT MARKING, ARROW, TYPE 2 (10.5 SQ. FT.) WHITE8'-3"5'-0"PRECAST CONCRETE CURB DETAIL1.CURB SHALL CONSIST OF 4,000 PSI AIR ENTRAINED CONCRETE, EXPOSED EDGES TO HAVERUBBED FINISH AND SURFACE SHALL BE TREATED WITH A CONCRETEPENETRANT/SEALER.2.THE ENDS OF CURB SECTIONS SHALL BE CHAMFERED 1/4 INCH.3.THE CORNERS OF CURB SECTIONS SHALL MATCH THE ADJACENT CURB IN SIZE, COLORAND FINISH.4.CURBS, CURB CORNERS OR EDGING SHALL BE FITTED TOGETHER AS CLOSELY ASPOSSIBLE.5.EXPANSION JOINTS SHALL BE INSTALLED AT A MAXIMUM OF TWENTY FEET (20') ONCENTER USING PREFORMED EXPANSION JOINT FILLER HAVING A THICKNESS OF 1/2 INCH.NOTE:TOPSOIL 6"6"12"6"MIN.7"6" MIN 6"MIN.COMPACTEDSUBGRADEBITUMINOUSCONCRETESURFACE COURSEGRAVEL BASE COURSEBITUMINOUSCONCRETE BASECOURSE34" RADIUSFINISH GRADEN.T.S.N.T.S.N.T.S.N.T.S.N.T.S.N.T.S.N.T.S.N.T.S.N.T.S.N.T.S.N.T.S.N.T.S.N.T.S.N.T.S.WHITELETTERSSPEED BUMP DETAILPAINTED 6" WIDEWHITE LINEPAINTED 6" WIDEWHITE LINES2' O.C.)WIDTH PER SITE PLAN OR 60"6"6"CROSSWALKMARKING6"x 12" M.U.T.C.D. REGULATORYSIGN #P3-8C (MODIFIED) BLUEON WHITE, REFLECTORIZED6"TOHEREYIELDR1-524"x24"BLACKLETTERS ANDLEGENDSWHITEBACKGROUNDYIELD SIGN(R1-2)BLACKBORDERYIELD SIGNN.T.S. REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY12345678REVISION 8 -01/19/2024CLIENT COMMENTSSGSW02/02/2024CITY COMMENTSSGVR03/04/2024CITY COMMENTSSGSW03/20/2024CITY COMMENTSSGVR04/15/2024CITY AND TDECOMMENTSAKDSRW05/03/2024PRELIMINARY ISSUEFOR CONSTRUCTIONAKDSRW06/07/2024DOT AND SCSDCOMMENTSAKDSRW06/14/2024ADDENDUM 1AKDSRW06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORP:\2023\NYB230191.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\NYB230191.00-SPPD-0A----->LAYOUT: C-902 DETLAD THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191SAG/AKDSRW11/30/2023NYB230191.00-SPPD-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK 2 - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comC-902DETAILSHEETTYPICAL UTILITY TRENCH(D+2' 3 MIN.)6"IN EARTHHALF SECTIONWHALF SECTIOND12"SELECT BACKFILLUNPAVED}PAVEDIN ROCK ANY SHEETINGDRIVEN BELOW MID-DIA.OF PIPE SHALL BE LEFTIN PLACEMATCHEXISTINGWATER, SEWER PIPEBACKFILL WITH GRAVELBEDDING TO MID-DIAMETERWHEN OTHER THAN PVC PIPEIS USEDBACKFILL WITH GRAVELBEDDING 12" OVER PIPEWHEN PVC PIPE IS USEDSHEETING (IF REQ'D) TO BE CUT OFF5' MIN BELOW GROUND & 2' MINABOVE TOP OF PIPE6" TOPSOIL & SEEDN.T.S.PIPE DIA.MIN. TRENCH WIDTH23"26"28"30"34"39"48"6"8"10"12"15"18"24"56"30"64"36"80"48"96"60"RECOMMENDED MIN. TRENCH WIDTHNOTES:1. ALL PIPE SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ASTM D2321 , "STANDARD PRACTICE FORUNDERGROUND INSTALLATION OF THERMOPLASTIC PIPE FOR SEWERS AND OTHER GRAVITY FLOW APPLICATIONS",LATEST ADDITION.2. MEASURES SHOULD BE TAKEN TO PREVENT MIGRATION OF NATIVE FINES INTO BACKFILL MATERIAL, WHENREQUIRED.3. FOUNDATION: WHERE THE TRENCH BOTTOM IS UNSTABLE, THE CONTRACTOR SHALL EXCAVATE TO A DEPTHREQUIRED BY THE ENGINEER AND REPLACE WITH SUITABLE MATERIAL AS SPECIFIED BY THE ENGINEER. AS ANALTERNATIVE AND AT THE DISCRETION OF THE DESIGN ENGINEER, THE TRENCH BOTTOM MAY BE STABILIZED USING AGEOTEXTILE MATERIAL.4. BEDDING: SUITABLE MATERIAL SHALL BE CLASS I, II OR III. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FORMATERIAL SPECIFICATION TO ENGINEER. UNLESS OTHERWISE NOTED BY THE ENGINEER, MINIMUM BEDDINGTHICKNESS SHALL BE 4" (100mm) FOR 4"-24" (100mm-600mm); 6" (150mm) FOR 30"-60" (7S0mm-900mm).5. INITIAL BACKFILL: SUITABLE MATERIAL SHALL BE CLASS I, II OR III IN THE PIPE ZONE EXTENDING NOT LESS THAN 6"ABOVE CROWN OF PIPE. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TOENGINEER. MATERIAL SHALL BE INSTALLED AS REQUIRED IN ASTM D2321, LATEST EDITION.6. MINIMUM COVER: MINIMUM COVER, H, IN NON-TRAFFIC APPLICATIONS (GRASS OR LANDSCAPE AREAS) IS 12" FROMTHE TOP OF PIPE TO GROUND SURFACE. ADDITIONAL COVER MAY BE REQUIRED TO PREVENT FLOATION. FOR TRAFFICAPPLICATIONS, MINIMUM COVER, H, IS 12" UP TO 48" DIAMETER PIPE AND 24" OF COVER FOR 54"-60" DIAMETER PIPE,MEASURED FROM TOP OF PIPE TO BOTTOM OF FLEXIBLE PAVEMENT OR TO TOP OF RIGID PAVEMENT.MIN. COVER TO FLEXIBLE PAVEMENT, HFINALBACKFILL6"SPRINGLINEINITIAL BACKFILLHAUNCHBEDDINGSUITABLE FOUNDATION4" FOR 12"-24" PIPE 6" FOR 30"-60" PIPEMIN. TRENCH WIDTH (SEE TABLE)HDPE STORM DRAINAGETRENCHN.T.S.N.T.S.N.T.S.N.T.S.N.T.S.N.T.S.N.T.S.N.T.S.N.T.S.N.T.S.MINIMUM BLANKET THICKNESSFLARED END SECTION (FES) DETAILSSEE PLANSEE PLAN1:2 MAX.TO MATCH PIPE MATERIALFLARED END SECTIONMIN.12"FILTER FABRIC MIRAFI 140 OR EQUALLIMIT OF STONE FILLINGLIGHT STONE FILLING12" MIN. DEPTH OF STONE4" ±SECTIONMIN.18"18"PLANMIN.TOP OF RIP-RAP TO ELEV. OF PIPECENTERLINE ON SIDE SLOPES OF INLETAND OUTLET CHANNELSCSD #1 SANITARY MANHOLESTORAGE BED (CLEAN, WASHED,OPEN GRADED AASHTO NO. 2 BROKENSTONE) (SEE NOTE #2)NOTES:1.PERMEABLE ASPHALT SURFACE COURSE TO UTILIZE TWO 3-INCH LAYERS OF POROUS ASPHALT PER NYSDEC STANDARDS. PERMEABLE ASPHALTSURFACE COURSE TO HAVE 15-25% POROSITY. FOR PARKING AREAS, A POLYMER MODIFIED BINDER PG 64E-22 MUST BE USED. PERVIOUSPAVEMENT SURFACE COURSE TO HAVE MINIMUM TESTED INFILTRATION RATE OF 6.4 IN/HR (20 IN/HR IF USED FOR STORMWATER QUALITYCONTROL).2.STORAGE BED AGGREGATE MUST BE PLACED IN LOOSE LIFTS NOT TO EXCEED 6 INCHES AND COMPACTED USING PLATE COMPACTORS PER NJSWBMP MANUAL.3.AT LEAST ONE INSPECTION PORT, WITH A REMOVABLE CAP, MUST BE PROVIDED IN THE STORAGE BED. THE INSPECTION PORT MUST BE PLACED ATLEAST 3 FEET FROM ANY EDGE & FLUSH WITH THE SURFACE OF THE SURFACE LAYER AND EXTEND DOWN 4 - 6 INCHES INTO THE STONE STORAGEBED, AND THE DEPTH OF RUNOFF FOR THE WATER QUALITY DESIGN STORM MUST BE MARKED ON EACH STRUCTURE. THE SIZE OF THE INSPECTIONPORT MUST BE LARGE ENOUGH TO ALLOW FOR MAINTENANCE ACTIVITIES.4.SEALANT, TOP COAT, AND OTHER TREATMENTS SHALL NOT BE USED ON THE PERVIOUS ASPHALT PAVEMENT COURSE. CONSTRUCTION MAY NOTTAKE PLACE DURING RAIN OR SNOW, NOR WHEN THE SUBSOIL IS FROZEN.5.TESTING MUST BE PERFORMED ON THE SUBSOIL PRIOR TO THE PLACEMENT OF THE STONE STORAGE BED IN ACCORDANCE WITH NJ SWBMPMANUAL CHAPTER 12. WHERE AS-BUILT TESTING SHOWS A LONGER DRAIN TIME THAN DESIGNED, CORRECTIVE ACTION MAY BE REQUIRED.6.PERVIOUS PAVEMENT AREA SHALL BE PROTECTED SEDIMENT-LADEN RUNOFF DURING CONSTRUCTION TO AVOID REDUCED POROSITY.WIDTH VARIES(SEE DRAINAGE PLAN)30"2" CHOKER COURSE(CLEAN, WASHED, AASHTO NO. 57 BROKEN STONE)6" PERVIOUS PAVEMENT SURFACE COURSE (SEE NOTE #1)TACK COATPAVEMENT JOINT2' MIN. SEPARATIONTO SHWTSTANDARD PAVEMENTSECTION (SEE DETAILS)WRAP FILTER FABRICALONG SIDESINSPECTION PORT(SEE NOTE #3)(SEE DETAIL)UNCOMPACTED SUBGRADE22"VARIES - SEE SHEET C-401300.00NYSDOT ITEM 402.378902 - 37.5 F9 H.M.A.3" ASPHALT CONCRETE BASE COURSENYSDOT ITEM 404.0982 - 9.5 F2 W.M.A. 80-SERIES COMPACTION2-1/2" ASPHALT CONCRETE BINDERNYSDOT ITEM 402.1989 - 19 F9 W.M.A.1-1/2" ASPHALT CONCRETE TOP COURSE12" GRANULAR SUBBASE COURSENYSDOT ITEM 304.12 - TYPE 2COMPACTEDAPPROVED SUBBASENOTES:1.CONTRACTOR TO VERIFY PAVEMENT THICKNESSAND NYSDOT ITEM NUMBERS WITH DOT PRIOR TOBIDDING AND CONSTRUCTION.2.NOT USED.3.EXISTING PAVEMENT BEING REMOVED SHALL BEREPLACED IN-KIND.4.PERMEABLE BASE COURSE SHALL BE REPLACEDTO MATCH ADJACENT PAVEMENT TO REMAIN.5.TACK COAT BETWEEN ALL ASPHALT LAYERS.6.NYSDOT PAVEMENT TO BE USED MINIMUM 30' FROMEDGE OF TRAVEL LANE OR WITHIN ROW,WHICHEVER IS GREATER.NYSDOT TYPICAL PAVEMENTSECTIONGC TO REFER TO GEOTECHNICAL REPORT BY WHITESTONE DATED 01/09/24 FOR PAVEMENT SPECIFICATIONS.BIT. CON. TOP COURSE(STANDARD DUTY =1 1/2")(HEAVY DUTY = 1 1/2")(NYSDOT 9.5MM F2)BIT. CONC. BINDER COURSE(STANDARD DUTY = 1 1/2")(HEAVY DUTY = 2 1/2")(NYSDOT 19MM F9)SUB-BASE COURSE(HEAVY DUTY AND STANDARD DUTY=12")(NYSDOT 304.12 TYPE 2)MIFRAFI 500X SYNTHETICFABRICPERVIOUS PAVEMENT SECTIONN.T.S.AS REQUIRED8"GRAVEL BASE (TYP)STEPS REQUIRED FORSTRUCTURES GREATERTHAN 5'-0" IN DEPTHBUTYL ROPEMANHOLE JOINTWOODARDS ORAPPROVED EQUALCONCRETE MANHOLESECTIONS, BY PRECAST REINFORCEDMIN.12"30" DIAM.6" MIN.OPTIONAL FILTERFABRIC (AS ORDERED BY ENGINEER)STONE OR R.O.B. GRAVEL)COMPACTED SUBBASE (CRUSHEDDISCONNECTQUICKPUMP IS OFF24.3"3"CONC. TANKALL JOINTS TOBE WATERTIGHT2" PVC TO FORCE MAINNOTE:ESTIMATED FLOAT SETTINGS ARE BASEDON A 4' DIA. TANK MEASUREMENT2"PUMP ONALARM ONPUMP CONTROLS AND ALARM TO BELOCATED INSIDE BUILDINGPRECAST CONCRETE ROOF SLABw/30" SQUARE ECCENTRICOPENINGPUMP RAILSYSTEMCONTRACTOR TO PROVIDE WEEP DRAINHOLE TO ALLOW FORCE MAIN TO PROP. 4" PVC VENT LINEALL JOINTS TOBE WATERTIGHTWATERTIGHT JOINTINLETPROP. DUAL HYDROMATICHVS200M0-2-HP GRINGER230V/3PHASE, (BY EMMONS PUMPOR APPROVED EQUAL)4'-0" (MIN.)4' DIAMETER PUMP CHAMBERPUMP & CONTROL NOTES:THE PUMP STATION SHALL CONTAIN THE FOLLOWING EQUIPMENT:1.TWO (2) DUPLEX SUBMERSIBLE EFFLUENT PUMP BY HYDROMATIC MODEL: HVC200M3-2 2HP GRINDER OR APPROVED EQUAL.2.ONE (1) DUPLEX FLOAT BASED PUMP CONTROLLER BY METROPOLITAN MODEL: ION INTELLIPUMP, OR APPROVED EQUAL WITH3 FLOATS AND HIGH WATER AUDIO AND VISUAL ALARM (GC TO COORDINATE WITH OWNER AND PROJECT ARCHITECT FORLOCATION OF CONTROL PANEL TO BE MOUNTED IN BUILDING)3.ONE (1) GUIDE RAIL KITS WITH 1"SST PIPE FOR RAILS AND SST LIFTING CHAIN BY CONERY OR APPROVED EQUAL4.ONE (1) SST FLOAT BRAKET5.THE CONTRACTOR SHALL INSURE THE PUMPS AND CONTROL SYSTEM ARE INSTALLED PER ALL MANUFACTURERSPECIFICATIONS AND RECOMMENDATIONS, CONFORMING TO LATEST NEC STANDARDS6.TANK PUMPS AND ACCESSORIES TO BE ACCESSIBLE FROM GROUND LEVEL.7.EMMONDS METRO LLC OR APPROVED EQUAL SHALL BE CONSULTED FOR PUMP PURCHASE AND INSTALLATION.PRECAST CONCRETE OR ASAPPROVED BY THE ENGINEER(6" MAXIMUM)30" COVER SHALL BEWATERTIGHT ANDLOCKABLE FRAME SHALL BE SET IN MORTAR BEDEMMONS METRO, LLC453 NORTH PEARL STREETALBANY, NY 12204DREW FOXPHONE: 518-807-7615TYPICAL PAVEMENT SECTIONN.T.S.NYSDOT SIDEWALK DETAIL(NYSDOT ITEM 304.12)(NYSDOT ITEM 608.0101)(NYSDOT ITEM 610.1403AND 610.1602)(NYSDOT ITEM 610.1403AND 610.1602)WIDTH VARIESSCSD #1 TRENCH DETAILN.T.S.SCSD #1 OUTDOOR GRINDER PUMP TOFORCE SANITARY MAIN CONNECTIONNOTE TO DESIGNER:1.RIP-RAP CONDUIT OUTLET PROTECTION TO BE BASED ON SOIL EROSION CONTROLCALCULATIONS.2.BE SURE TO UPDATE THE F.E.S. NUMBERING AND RIPRAP SIZING SCHEDULE.W2 (SEEPLAN)L1 (SEE PLAN)9" MIN.W10% GRADEFLARED END SECTION(SEE DETAIL)PIPEd50PLAN VIEWSECTIONSLOPESEE GRADING PLAN't' (MIN. 12")X"X"X'X'X'X'X'X'#X#XGRADENOTE:1.SEE PLAN FOR LOCATIONS. AT LEAST ONE INSPECTION PORT MUST BE PROVIDED IN THESTORAGE BED. THE INSPECTION PORT MUST BE PLACED AT LEAST 3 FEET FROM ANY EDGE &FLUSH WITH THE SURFACE OF THE SURFACE LAYER AND EXTEND DOWN 4 - 6 INCHES INTO THESTONE STORAGE BED, AND THE DEPTH OF RUNOFF FOR THE WATER QUALITY DESIGN STORMMUST BE MARKED ON EACH STRUCTURE. THE SIZE OF THE INSPECTION PORT MUST BE LARGEENOUGH TO ALLOW FOR MAINTENANCE ACTIVITIES.8"8"24"COUPLING4" PVC PIPE4,000 PSICONCRETE ON MIN.95% COMPACTEDSUBGRADEPERVIOUS PAVEMENT(SEE PERVIOUSPAVEMENT DETAIL)CAMBELL FND. Co. COVER &CIRCULAR FRAME #4155 ORAPPROVED EQUIVALENTPVC PLUG4" PERFORATEDPVC PIPE6"6"3/4" CLEAN STONEINSPECTION PORT FOR PERVIOUSPAVEMENT DETAILFLARED END RIP-RAP DETAIL REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY12345678REVISION 8 -01/19/2024CLIENT COMMENTSSGSW02/02/2024CITY COMMENTSSGVR03/04/2024CITY COMMENTSSGSW03/20/2024CITY COMMENTSSGVR04/15/2024CITY AND TDECOMMENTSAKDSRW05/03/2024PRELIMINARY ISSUEFOR CONSTRUCTIONAKDSRW06/07/2024DOT AND SCSDCOMMENTSAKDSRW06/14/2024ADDENDUM 1AKDSRW06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORP:\2023\NYB230191.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\NYB230191.00-SPPD-0A----->LAYOUT: C-903 DETLAD THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191SAG/AKDSRW11/30/2023NYB230191.00-SPPD-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK 2 - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comC-903DETAILSHEETTRASH ENCLOSURE DETAILN.T.S.5/4"x6" BOARDS(TREX, BOLTEDTO FRAME)LATCHCOLLARS1/2" STEEL PLATEPIPE SLEEVESHEIGHT TO MATCH WALL 8"3" 2'-0"4"(NOTE: FOUNDATION DESIGN TO BE PROVIDED BY CONTRACTOR)(NOTE: FOUNDATION DESIGN TO BE PROVIDED BY CONTRACTOR) 3/4" MIXED WATER WITH FREEZE PROOF HOSE BIBB.6" DIA. CONCRETE FILLEDSTEEL POST (TYP)TO DRAINSLOPETO DRAINSLOPE20'2'3'10'10' 2'17'25'12'2x2 POST5/4 x 6 WALL SLATS2x4 HORIZONTAL RAIL3/16" SPACINGNOTES:1.EQ. 6' 3"8" 4000 PSI CONCRETE SLABWITH #4 REBAR REINFORCING,12" O.C. EACH WAY, OVER 6 MILPOLY. VAPOR BARRIER ON 12"COMPACTED GRAVEL BASEOVER COMPACTED SUBGRADEEQ.EQ.2 X 2 STEEL POSTS COREDINTO SLAB AT 4'-0" O.C.6" MIN. EMBEDMENT2 X 4 BOLTED TOSTEEL POSTS(TYP. OF 4)TREX CAP12"MIN.#4 TOPPERIMETER BARPAINT POSTS W/BENJAMIN MOORESTEEL PRIMER ANDBLACK PAINTCLEXPANSION JOINT3/16"6'RAILS (TYP OF 4 ROWS2x4 HORIZONTAL3"(TYP)GAPPAVEMENTTOP OF SLAB/5/4" x 6 (TREX) WALL SLATS MOUNTED ON OUTSIDE (CONFIRM COLOR WITH ARCH.)EVENLY SPACED)TREX CAPWELD TO FRAMEPOURED CONCRETE1"HEIGHT TO MATCH WALL AS REQUIRED BY CODE OR TO ACHIEVE ADEQUATE SOIL BEARING 6" 8"1'-6"6"6"3"SONO TUBE4'-0" MAX 5/4" X 6" TREXFASTENED TO 2 X 4'SALL WOOD MEMBERS OF TRASH CORRALARE TO BE PRESSURE TREATED. ALLFASTENERS ARE TO BE GALVANIZED.METAL COLLAR TO FITOVER 6" DIA POSTGREASE AREA BETWEENPOST & HINGEHYDRAULIC GREASE FITTINGDRILL AND TAP HOLE (TYP. 4PLACES)METAL COLLAR TYP. WELDBOTTOM COLLAR TO POST,BOLT TOP COLLAR6" DIA. CONCRETEFILLED STEEL POSTSTEEL ANGLE FRAME & DIAGONALBRACES (GRIND WELDS ANDCORNERS SMOOTH, PAINT W/2COATS BLACK RUSTOLEUM)ALEMITE 1610-BL HYDRAULICGREASE FITTING (TYP. 4 PL)2" ELECTRIC CONDUIT @36" ABOVE FINISHEDFLOOR. 8" CONCRETE PAD3'CRANE BOLTS6" DIA GATE POST(SEE DETAIL)1" NIPPLE WELDEDTO PLATE3/4" CANE BOLTW/4" HOOK1/2" BOLTSTO FRAMEN.T.S.N.T.S.N.T.S.N.T.S.N.T.S.HANDRAIL DETAILPOST AND RAIL FENCE38" MAX. 34" MIN.GROUT POCKET DETAIL6" TYP.1:12 MAX. SLOPEAS REQUIRED FOR30' MAXIMUMSPECIFICATIONS:1. RAMP AND HANDRAIL TO BE INSTALLED IN ACCORDANCE WITH SECTION 405 & 505OF THE AMERICAN NATIONAL STANDARD- ICC/ANSI A117.1.2. MATERIAL - 1.25" OR 1.50" O.D. SCH 40 ALUMINUM OR STEEL PIPE.3. FINISH - HARDCOAT BLACK ANODIZED OR SEMI GLOSS BLACK PAINTED.4. ALL WELDS SHALL BE GROUND SMOOTH5. APPROVED MANUFACTURERS-LOCAL FABRICATION OR CRANE VEYOR CORP (818)442-1524 MODEL NO. C4300 OR MOULTRIE MFG. CO. (800) 841-8674 WESRAIL SYSTEM.EDGE OFWALKMINIMUM DIAMETER = 1.25"MAXIMUM DIAMETER = 1.50"MAX. 1:12 SLOPERAMP SURFACEGROUT POCKET(TYP.)EQUALEQUAL5'-0" CLEAR WIDTH(UNLESS OTHERWISENOTED ON SITE PLAN)6" HOLD27" MAX.12" (MEASURED TO THESTART OF THE INSIDERETURN RADIUS)12" (MEASURED TO THE START OFTHE INSIDE RETURN RADIUS)NOTES:1. RAMP SURFACE MAY NOT EXTEND INTO ANY PORTION OF THE PARKING SPACE ORASSOCIATED STRIPED ISLAND.2. RAMPS, HANDRAILS & APPLICABLE SIGNAGE SHALL BE CONSTRUCTED INACCORDANCE WITH THE LATEST A.D.A. ACCESSIBILITY GUIDELINES.3. RAMP RUNS SHALL HAVE A MAXIMUM RISE OF 30" BEFORE A MIN. 5.0' x 5.0' LEVELLANDING AREA PER A.D.A. ACCESSIBILITY GUIDELINES IS REQUIRED.4. RAMPS & LANDINGS SHALL BE DESIGNED TO PREVENT WATER ACCUMULATION WITHINSLOPE REQUIREMENTS OF A.D.A. ACCESSIBILITY GUIDELINES.5. IN INSTANCES WHERE DROP HEIGHT MEASURED FROM RAMP SURFACE TO ADJACENTFINISHED GRADE EXCEEDS 30", INTERMEDIATE VERTICAL RAILS SHALL BE INSTALLED INACCORDANCE WITH APPLICABLE STATE BUILDING CODE. CLEAR SPACE BETWEENVERTICALS SHALL BE LESS THAN 4-INCHES.4" (MAX.)4" (MAX.)4" (MAX.)PROVIDE MAX 30" REVEAL/DROP HEIGHT TOADJACENT FINISHED GRADE (SEE NOTE #5)FINISHED GRADENOTES:1. POST AND RAILS TO BE UNTREATED CEDAR OR PRESSURE TREATED PINE OR EQUIVALENT.2. BACKFILL AND COMPACT 12" DEEP WITH 3/4" CLEAN STONE, PLACE IN 6" LIFTS.3.PLACE 2,500 PSI CONCRETE OR GROUT AROUND THE POST UP TO BOTTOM OF THE TOP SOIL.TAPPING SLEEVE & GATE VALVE DETAIL(DETAIL FOR GENERAL PURPOSES. GC TO COORDINATE CONNECTION W/ CITY OF SARATOGA DEPARTMENT OF PUBLIC WORKS)EXISTING WATER MAINTAPPING SLEEVETAPPING VALVE & BOXTAPPING VALVE & BOXCONCRETE THRUST BLOCKUNDISTURBED MATERIALWATER QUALITYFILTER FABRIC6" DIA. PERFORATEDUNDERDRAIN PIPE IN 6" GRAVEL JACKET PERMEABLE SOIL (DEPTH VARIES)PER NRCS CLASS SM (NRCS, 1984) (PERCOLATION RATE = 10 MIN/IN)2:1 SIDE SLOPEOR FLATTER2:1 SIDE SLOPEOR FLATTERGRASS (TYP)GRASS (TYP)BOTTOM WIDTHVARIES (2' MIN., 8' MAX.)1'DRY SWALE DETAIL6"30"N.T.S.LVEGETATED SWALE DETAIL4" TOPSOIL ANDSEEDINGEXISTING SOILOR EARTH FILL3'-0"12" MIN.C3:1 SIDE SLOPEGRASS (TYP)3:1 SIDE SLOPEN.T.S.6" PUROK NON-SHRINKINGSLEEVE FILLERISOMETRIC VIEWSECTION A-ATOP VIEW(COVERS REMOVED FOR CLARITY)SPECIFICATIONSNotes:6" plain end inlet/outlet1.Unit weight - w/ cast iron covers: 1,290 lbs. (for wet weight add2.12,525 lbs.)Maximum operating temperature: 150º F continuous3.Capacities - Liquid: 1,500 gal.;4.Grease: 10,061 lbs. (1,379 gal.) @100GPMGrease: 9,446 lbs. (1,294 gal.) @200GPMSolids: 318 gal.Satisfies Miami DERM 99% efficiency requirements; retaining the5.following capacities at 99% efficiency:9,897 lbs. (1,356 gal.) @100GPM8,093 lbs. (1,109 gal.) @200GPMFor gravity drainage applications only.6.Do not use for pressure applications.7.Cover placement allows full access to tank for proper8.maintenance.Vent not required unless per local code.9.Engineered inlet and outlet diffusers with inspection ports are10.removable to inspect / clean piping.Integral air relief / Anti-siphon / Sampling access.11.Adjustable cover adapters provide up to 4" of additional height.12.Designed for below-grade, above-grade, indoor or outdoor13.installations.Safety Star®, access restrictor built into each cover adapter,14.prevents accidental entry to tanks(450 lb rating).Satisfies Miami DERM 99% efficiency requirements. Product labels arepermanently attached to inside and outside of unit for easy viewing.ENGINEER SPECIFICATION GUIDESchier Great Basin™ grease interceptor model #GB-1500 shall be lifetime guaranteed and made inUSA of seamless, molded polyethylene withminimum 7/16" uniform wall thickness. Interceptorshall be furnished for above or below-grade installation withadjustable cover adapter and Safety Star® accessrestrictor built into each cover adapter. This unit is certifiedfor hydromechanical performance to ASME A112.14.3/CSAB481.1-2022 (Type D) as well as certified toANSI/CAN/IAPMO Z1001-2021 for gravity greaseinterceptors. Flow control not required.Interceptor flow rate shall be 100 GPM or 200 GPM.Interceptor grease capacity shall be 10,061 lbs. Covershall provide water/gas-tight seal and haveminimum 16,000 lbs. load capacity.CERTIFIED PERFORMANCEGreat Basin™ hydromechanical grease interceptors are thirdparty performance-tested and listed by IAPMO to ASMEA112.14.3/CSA B481.1-2022 (Type D) grease interceptorstandards and greatly exceed requirements for greaseseparation and storage. They are compliant to the UniformPlumbing Code and the International Plumbing Code.6455 Woodland DrShawnee, KS 66218Tel: 913-951-3300Fax: 913-951-3399schierproducts.comDESCRIPTION:DWG BY:DATE:REV:THE INFORMATION CONTAINED IN THIS DRAWING ISTHE SOLE PROPERTY OFSCHIER PRODUCTS. ANYREPRODUCTION IN PART OR AS A WHOLE WITHOUTTHE WRITTEN PERMISSION OFSCHIER PRODUCTSISPROHIBITED.PROPRIETARY AND CONFIDENTIALT.ASAY12/13/2022CECO:MODEL NUMBER:GREASE INTERCEPTOR 100 GPM / 200 GPM, 6" PLAININLET/OUTLET, H-20 RATED PICKABLE CAST IRON COVERS121423CS4085-001-01PART NUMBER:GB-1500SPECIFICATION SHEETFLOW1372741 1/241 1/22773 51/64FLOWSafety Star®AA5313 1/45856CLof 6" inletCLof 6" outletEngineered inlet andoutlet diffuser(see description)Static Water LineAdjustable adapters withpickable H-20 rated castiron coversBB6871 1/4SECTION B-BBaffle Wall Openingfor fluid pass throughVent openingbetween tankcompartmentsN.T.S.SCHIER GREASE INTERCEPTOR DETAILALL COLLARS, FRAMES,POSTS AND FITTINGSSHALL BE PAINTEDBLACKNOTE:1. GC TO INSTALL TANK ACCORDINGTO MANUFACTURER INSTALLATIONINSTRUCTIONS.2. IN VEHICULAR TRUCK TRAFFICINSTALLATION AREAS, A MINIMUM 8"THICK CONCRETE SLAB WITH REBARIS REQUIREDGATE VALVENOT TO SCALE(S500.03xx_07/2022)SLOPESLOPE2' SQ X 6" THICK CLASSB CONCRETE PADVALVE BOX TOSUIT VALVE ANDDEPTH OF BURYTAMP BACKFILLVALVE BODYWATER PIPEVALVE BOX TO BE ENTIRELYSUPPORTED BY CONCRETE BLOCKSOR BRICKS TO SUIT. VALVE BOXMUST NOT BEAR ON VALVE OR PIPE.ADJUST TOP SECTIONTO FINISH GRADE N.T.S.N.T.S.REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY12345678REVISION 8 -01/19/2024CLIENT COMMENTSSGSW02/02/2024CITY COMMENTSSGVR03/04/2024CITY COMMENTSSGSW03/20/2024CITY COMMENTSSGVR04/15/2024CITY AND TDECOMMENTSAKDSRW05/03/2024PRELIMINARY ISSUEFOR CONSTRUCTIONAKDSRW06/07/2024DOT AND SCSDCOMMENTSAKDSRW06/14/2024ADDENDUM 1AKDSRW06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORP:\2023\NYB230191.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\NYB230191.00-SPPD-0A----->LAYOUT: C-904 DETLAD THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191SAG/AKDSRW11/30/2023NYB230191.00-SPPD-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK 2 - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comC-904DETAILSHEETTHRUST BLOCK DETAILTRENCH WALLTRENCH WALLCROSS WITH PLUGCROSSCONCRETETEE WITH PLUGCONCRETECONCRETETRENCH WALLTEECONCRETE(ALL BENDS SIMILAR)90° BENDCONCRETEREQUIRED SQ. FT. OF UNDISTURBEDEARTH WALL FOR REACTION BACKINGTYPE OF FITTINGSPIPESIZEBENDSTEE &PLUG90°45°22111/2°4°/1HORIZONTAL THRUST BLOCKING(BLOCKING HEIGHT GREATER THAN PIPE O.D.)(BLOCKING WIDTH BETWEEN 1 & 2 TIMES HEIGHT)6"8"10"12"1.52.54.06.02.01.01.01.03.51.81.01.05.52.81.51.08.04.02.01.53"4"1.01.01.01.01.01.01.01.01.01.0NOTES:1.DO NOT COVER BELLS OR FLANGES WITH CONCRETE2.WRAP ALL FITTINGS WITH VISQUEEN.3.BACK ALL TEES ACCORDING TO SIZE OF BRANCH.4.BACKING FUTURE LINE EXTENSIONS SHALL BE SUCH THAT LATER REMOVAL IS POSSIBLE.5.ALL BENDS WHERE FITTINGS ARE USED, BOTH HORIZONTAL OR VERTICAL SHALL BE BACKED.6.REACTION BACKING TABLE IS BASED ON 100 P.S.I. AND SOIL BEARING PRESSURE OF 2000LB./SQ.FT. ADDITIONAL BACKING MAY BE REQUIRED IN SOME AREAS AS DIRECTED BYENGINEERS.7.ALL CONCRETE SHALL BE 2500 P.S.I.8.18" AND LARGER REQUIRES SPECIFIC ANTI-THRUST DESIGN.AAEDGE OF PONDEMBANKMENTPLAN VIEWELEVATION VIEWPOND BOTTOMSECTION A-AE M B A N K M E N T6" HDPETOP ELEV.=302.80ELEV.=302.00BOTTOM OF POND302.00OUTLET CONTROL STRUCTURE12" COMPACTED GRAVEL6" OUTLET PIPETRASH RACK4' Ø PRECAST CATCH BASINBASE AND RISER SECTIONSTOP OF STRUCTURES AT ELEV. 302.80CATCH BASIN GRATE AT ELEV. 302.80OUTLET STRUCTURETRASH RACKN.T.S.N.T.S.N.T.S.This drawing is for reference only. Determination of the suitability and/or manner of use of any details contained in this document is the sole responsibility ofthe design engineer of record. Final project designs, including all construction details, shall be prepared by a licensed professional engineer using the actualconditions of the proposed site.Leveling pad (As specified by Engineer)Drain (As specified by Engineer)Drainstone (AASHTO No. 57 or equivalent)to extend at least 12" (305 mm) behind blocksNon-woven geotextile fabric(If specified by Engineer based onsite soil conditions)Fill wedge between adjacent blockswith drainstone (all blocks)Fill vertical core slot with drainstone(PC blocks)Solid bottom blockBlock widths vary with designMiddle block (Typical)Block widths vary with designTop blockExposed wall(Height varies withdesign)Move blocks forward during installationto engage shear knobs (Typical)Grade to drain surface wateraway from wallRETAINED SOILBury depthSetback = 1 58" (41 mm)(5° batter angle on wall)N.T.S.REDI-ROCK LEDGESTONE WALL WITH MOUNTED PRIVACY SCREEN DETAIL (BY MANUFACTURER)These generic pedestrian guard and fencedetails show a few potential options for theirinstallation on the top of a Redi-Rock retainingwall. It is the design engineer's responsibilityto fully design and detail the connection of theguard posts to the retaining wall blocks andassure acceptable resistance to the appliedforces. Redi-Rock blocks are plain concrete,without steel reinforcement.Flange base plate attachedto top block with adhesiveset anchor boltsField core intoTop blockGrout fence or railingpost in placeReinforced concrete sidewalkFence or railing postCore and grout or connectwith flanged base plateGrout fence or railingpost in placeField core into blockin second courseGrouted Connection(1 Block)Flange Bolted ConnectionGrouted Connection(2 Blocks)Moment Slab ConnectionNYSDOT CULVERT TRENCH DETAILNYSDOT ITEM603.9824NYSDOT ITEM 203.07NYSDOT SIGN PANEL DETAILS FOR GUIDE, INFORMATION AND OTHER SIGNS45°2"5'4" MIN2.5"2.5"BOLT STAINLESS STEEL ANGLE FRAME TOOUTLET CONTROL STRUCTURE WITHSTAINLESS STEEL BOLTSSTAINLESS STEELANGLE FRAME1/4" THICK X 1/4" STAINLESSSTEEL CRATE. WELD TOSTAINLESS STEEL ANGLEFRAME WITH 2.5" X 2.5"OPENINGS.OUTLETCONTROLSTRUCTURETRASH RACKNOT TO SCALE(NE-U019903 - 09/2023)SECTION A-AFLOWS=0.005 MINMIN4"MIN12"MINNEENAH TYPE A GRATECOVER CATALOGNo. R 4999 FX1 12"x 1 12"x 14" GALV. SEAT ANGLE W/2"STUDS EMBEDDED IN CONC.SEE SITE PLANFOR RIM ELEV.CAST IRON TRAP BYNEENAH R 3701 ORAPPROVED EQUALSEE SITEPLAN FOR RIMELEV.12" COMPACTED GRAVELWWF 4x4; W1.4xW1.4SEE SITEPLAN FORINV.12"1'-0"4" MIN 18"8" - 0"4" MIN 1 1/2" 1 1/2"2'-0" MIN(SUMP ONLY)AA2SECTION A-A311SECTION B-BPLAN VIEWAABBFLOWFLOWINSTRUCTIONS TO DESIGNER:1.CIP CURB IS PREFERRED TO PREVENT THE POTENTIAL OF PRECAST CONCRETECURBING (PCC) NOT BEING INSTALLED CORRECTLY AND WATER PENETRATINGBETWEEN THE JOINTS. CIP CURB CAN BE REPLACED WITH PCC AT REQUEST OF THECLIENT, CONTRACTOR OR REVIEWING AUTHORITY. IF PCC IS USED THE DETAIL SHALLBE EDITED ACCORDINGLY AND ALL JOINTS SHALL BE NOTED AS MORTARED.1'-0" STONE FOR PIPE ENDSFILTER FABRIC6" LOAM AND SEEDCAST-IN-PLACECONCRETE CURB (CIP).CIP SHALL EXTEND INTOBERM A MINIMUM OF 2 FT.COMPACTED LOWPERMEABILITY COREDIKE BEYONDSTONE FOR PIPE ENDSCOMPACTED LOWPERMEABILITY CORECAST-IN-PLACE CONCRETE CURB (CIP). CIPSHALL EXTEND INTO BERM A MINIMUM OF 2 FT.CONTINUE CHANNEL SHAPETO BOTTOM OF SLOPE18"5'-0"W=SEE TABLE5'-0"D=0'-6" MINCAST-IN-PLACECONCRETE CURB (CIP).CIP SHALL EXTEND INTOBERM A MINIMUM OF 2 FT.TOP OF BERMSPILLWAY DIMENSIONS AND ELEVATIONSBASINTOP OF BERMELEV A (FT)SPILLWAY CRESTELEV B (FT)WIDTH W OFSPILLWAY (FT)E. INFILTRATIONBASIN306.00304.2510W. INFILTRATIONBASIN304.00302.90155'-0" (TYP).5'___ELEV A (TOP OF BERM) - SEE TABLE___ELEV B (SPILLWAY CREST) - SEE TABLEFILTERFABRICTRASH RACK DETAILPOURED-IN-PLACE CONC. TRENCH DRAINN.T.S.EMERGENCY SPILLWAY DETAILN.T.S.NOTES:1.THIS TYPICAL DETAIL IS NOT FOR CONSTRUCTION AND IS PRELIMINARY AND CONCEPTUAL IN NATURE. THIS DETAIL IS PROVIDED FOR GRAPHICAL REFERENCE PURPOSESONLY. DESIGN OF THE PROPOSED RETAINING WALL(S) SHALL BE PREPARED BY THE APPROPRIATE PROFESSIONAL (E.G. STRUCTURAL ENGINEER) LICENSED IN THESTATE WHERE THE CONSTRUCTION OCCURS. THE PROFESSIONAL SHALL BE FAMILIAR WITH THE ACTUAL SITE CONDITIONS AND MATERIALS AS WELL AS APPLICABLE,LOCAL, STATE AND FEDERAL REGULATIONS.2.RETAINING WALL & ANY ASSOCIATED REINFORCEMENT SHALL BE DESIGNED ACCOUNTING FOR SOIL TYPES, WATER TABLE ELEVATION, EXISTING & PROPOSEDSURROUNDING IMPROVEMENTS/CONDITIONS (INCLUDING BUT NOT LIMITED TO SLOPES, DRIVE AISLES, ROADS, FENCING (INCLUDING WIND LOAD), GUIDERAILS(INCLUDING COLLISION LOADING), UTILITIES, DRAINAGE FACILITIES, STRUCTURES, FOUNDATIONS), LIVE LOADS AND OTHER SITE AMENITIES THAT COULD HAVE ANINFLUENCE OR IMPACT ON THE RETAINING WALL(S) CONSTRUCTABILITY AND/OR LONGEVITY SHALL BE CONSIDERED AND INCORPORATED INTO THE RETAINING WALLDESIGN AS WELL AS THE GLOBAL STABILITY ANALYSIS.3.RETAINING WALL DESIGNER SHALL ACCOUNT FOR MULTIPLE STORM STRUCTURES BEHIND WALL INCLUDING PARALLEL STORM PIPE THAT MAY INTERFERE WITH THEDESIGN OF THE WALL AND ANY ASSOCIATED REINFORCEMENT.4.SEE GRADING AND DRAINAGE PLAN FOR PROPOSED ELEVATIONS AND SLOPES ASSOCIATED WITH SAME.5.REFER TO GENERAL GRADING NOTES ON SHEET C-102 FOR ADDITIONAL NOTES REGARDING DESIGN AND CONSTRUCTION OF RETAINING WALLS.6.DRAIN PIPE SHALL DISCHARGE TO CRUSHED STONE PAD AT GRADE (I.E. DAYLIGHT) OR CONNECT TO PROP DRAINAGE SYSTEM IF UNABLE TO DAYLIGHT. A RODENTSCREEN SHALL BE PROVIDED AT PIPE END WHERE PIPE DAYLIGHTS.7.THIS DETAIL IS NOT APPLICABLE FOR WALLS UTILIZED TO RETAIN WATER.8.MATERIALS UTILIZED IN CONSTRUCTION OF THE RETAINING WALL SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S AND WALLDESIGNER'S SPECIFICATIONS INCLUDING ANY REQUIRED COMPACTION AND TESTING. REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY12345678REVISION 8 -01/19/2024CLIENT COMMENTSSGSW02/02/2024CITY COMMENTSSGVR03/04/2024CITY COMMENTSSGSW03/20/2024CITY COMMENTSSGVR04/15/2024CITY AND TDECOMMENTSAKDSRW05/03/2024PRELIMINARY ISSUEFOR CONSTRUCTIONAKDSRW06/07/2024DOT AND SCSDCOMMENTSAKDSRW06/14/2024ADDENDUM 1AKDSRW06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORP:\2023\NYB230191.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\NYB230191.00-SPPD-0A----->LAYOUT: C-905 DETLAD THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191SAG/AKDSRW11/30/2023NYB230191.00-SPPD-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK 2 - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comC-905TRAFFICCONTROLPLANSITE SPECIFIC WORK ZONE TRAFFIC NOTES·THERE SHALL BE NO TEMPORARY LANE CLOSURES ON ROUTE 9 NB, MONDAY - FRIDAY 4PM-6PM·THERE SHALL BE NO TEMPORARY LANE CLOSURES DURING THE FOLLOWING SPECIAL EVENTS: SARATOGA RACETRACK SEASON ORTHE WEEKEND OF THE BELMONT STAKES.·LANE CLOSURES AND/OR USE OF TEMPORARY CONCRETE BARRIER WITHIN FIVE FEET OF AN ACTIVE TRAVEL WAY BETWEENNOVEMBER 1 & APRIL 15 SHALL REQUIRE SPECIAL PERMISSION FROM THE ENGINEER WITH CONCURRENCE FROM THE REGIONALTRAFFIC OFFICE. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK IN ADVANCE OF ANY REQUESTED CLOSURE.·PRIOR TO ANY REDUCTION IN ROADWAY WIDTH, THE CONTRACTOR SHALL PROVIDE THE ENGINEER TWENTY-ONE (21) DAYS NOTICEIN WRITING SO HE/SHE MAY CONTACT THE REGIONAL PERMIT ENGINEER OF THE WIDTH RESTRICTION IN A TIMELY MANNER. THECONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING IMMEDIATELY UPON THE REMOVAL OF THE LANE WIDTH RESTRICTION SOTHE ENGINEER MAY NOTIFY THE REGIONAL PERMIT ENGINEER.·THE CONTRACTOR MST BE PREPARED TO SWEEP THE ROAD DAILY OR AS ORDERED BY NYSDOT SARATOGA COUNTY RESIDENCY.·THE CONTRACTOR SHALL MAINTAIN PEDESTRIAN AND BICYCLE TRAFFIC THROUGH AND AROUND THE PROJECT FOR THE DURATIONOF CONSTRUCTION. MATERIAL, EQUIPMENT OR OTHER BARRIERS SHALL NOT BE PLACED OR MARKED IN SUCH A MANNER AS TOOBSTRUCT PEDESTRIAN OR BICYCLE TRAFFIC OR TO PRESENT A SAFETY HAZARD TO THE NON-MOTORIZED PUBLIC. WHEREPEDESTRIAN TRAFFIC MUST BE RELOCATED OFF THE EXISTING FACILITY, WALKWAYS SHALL BE CLEARLY MARKED AND HAVE ALOGICAL START AND TERMINUS.·HOLIDAY TEMPORARY LANE/SHOULDER RESTRICTIONS TABLE. REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY12345678REVISION 8 -01/19/2024CLIENT COMMENTSSGSW02/02/2024CITY COMMENTSSGVR03/04/2024CITY COMMENTSSGSW03/20/2024CITY COMMENTSSGVR04/15/2024CITY AND TDECOMMENTSAKDSRW05/03/2024PRELIMINARY ISSUEFOR CONSTRUCTIONAKDSRW06/07/2024DOT AND SCSDCOMMENTSAKDSRW06/14/2024ADDENDUM 1AKDSRW06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORP:\2023\NYB230191.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\NYB230191.00-SPPD-0A----->LAYOUT: C-906 DETLAD THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191SAG/AKDSRW11/30/2023NYB230191.00-SPPD-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK 2 - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comC-906TRAFFICCONTROLPLAN C/OSC/OS20' SIDE YARD SETBACK(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO RE M A I N )(TO REMAIN)20' SIDE YARD SETBACK60' FRONT YARD SETBACK TRIDGELINE RIDGELINERIDGELINE WETLAND "A"AREA=0.53 ACRES60'5.8'T9'5'5'6.6'9'32.5'5'8'8'2'20'38.2'30.3'15'65.4'R22.8'32'11.5'23.2'10'L B LBLBLBLB4.2', TYP.6'6'6'3'8'8'LBLBLBLB27.2'8'68.5'9'R3'R 3 ' 12.6'18.8'5.5'5.5'20.5'5.6'5.5'10'10'5'R21.6'37.9'27.3'5.2'14.9'44.9'52.4'22', TYP.6', TYP.16.7'5.9'25'19.7'5.5'67.1'9'14'9'27.7'90.1'31'48'48'30.9' 21.9'L= 82.0'R= 46.0'L= 66.4'R= 196.4'L= 17.4'R= 12.3'L= 36.0'R= 75.0'L= 70.0'R= 158.3'L= 104.7'R= 263.1'L= 18.4'R= 10.3'L= 38.1'R= 39.6'L= 56.4'R= 43.2'L= 40.5'R= 36.9'L= 62.5'R= 75.1'L= 55.0'R= 57.6'L= 101.5'R= 50.3'L= 55.7'R= 22.8'L= 33.9'R= 165.5'L= 117.8'R= 192.4'L= 36.5'R= 194.7'L= 47.7'R= 152.6'L= 21.1'R= 13.7'L= 27.3'R= 71.0'5'8'L= 44.2'R= 26.2'20'20'6.6'L= 65.0'R= 30.0'L= 59.7'R= 31.3'L= 102.1'R= 114.9'L= 62.3'R= 76.0'L= 44.6'R= 45.4'L= 32.8'R= 108.8'L= 66.3'R= 33.6'L= 33.6'R= 189.5'B S BSB S B S TTTB S B S TTTTFLUSHREVISIONSREVDATECOMMENTDRAWN BYCHECKED BY1234567REVISION 7 -01/19/2024CLIENT COMMENTSDTMM02/02/2024CITY COMMENTSDTMM03/04/2024CITY COMMENTSDTMM03/20/2024CITY COMMENTSDT/JKMM04/15/2024CITY AND TDECOMMENTSDTMM05/03/2024ISSUED FORCONSTRUCTIONDTJE/MB06/14/2024ADDENDUM 1DTJE06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORC:\PROGRAMDATA\_BOHLER\C3D2024\TEMP\ACPUBLISH_11952\NYB230191.00-LSCP-0A----->LAYOUT: L-100 LAYOUTDT THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191DT/JKJE/MB11/30/2023NYB230191.00-LSCP-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comM A T THEW J. MRVA002359R E GISTE R E D LANDSCAPE ARCHITECTSTATE OF NEW YOR K EXCELSI OREXP: 06/30/2024LANDSCAPE PLANS TO BE READ INCONJUNCTION WITH NOTES, DETAILSAND SPECIFICATIONS1"=40'040102040WESLAYOUT LEGENDR6.4'LAYOUT ELEMENTSSYMBOLDESCRIPTIONPOINT OF BEGINNINGDIMENSIONRADIUSCENTERLINEVERIFY DIMENSION IN FIELDEQUAL0.5'POBEQVIFL-100LANDSCAPELAYOUTPLAN66 C/OSC/OS20' SIDE YARD SETBACK(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO RE M A I N )(TO REMAIN)20' SIDE YARD SETBACK60' FRONT YARD SETBACK TRIDGELINE RIDGELINERIDGELINESOUTH BROADWAYU.S. ROUTE 9 WETLAND "A"AREA=0.53 ACRESPROP.EARTHWORKSBERM, TYP.PROP.CONCRETE PATH TOTIE INTO EXISTING, TYP.TPROP.NATIVE TREEPLANTING, TYP.PROP.SHRUBPLANTING, TYP.PROP. TIMBER FENCE TO REPLACE EXISTINGCHAIN LINK AND TIE INTO EXISTING VINYL FENCEPROP. VINYL FENCETERMINATES AT WETLAND1L-603PROP.NATIVE MEADOWSEED MIX, TYP.13L-603PROP.18" GRAVEL MAINTENANCESTRIP ADJACENT BUILDING, TYP.11L-603PROP.SEEDED LAWN, TYP.9L-603PROP.(2) TIMBER BENCH ONCONCRETE PAD, TYP.9L-6024L-603PROP.STORMWATERBASIN SEED MIX, TYP.7L-6033L-603PROP.STAMPEDCONCRETE PAVEMENT1L-601PROP.TIMBER SWINGPLATFORM, TYP.4L-601PROP.(8) LIGHTBOLLARD, TYP.10L-60212L-602PROP.TIMBERPLATFORM, TYP.1L-601PROP.(3) STAMPED CONCRETEPAVEMENT PAD, TYP.PROP.TRASH ENCLOSURE ANDBOLLARDS - SEE CIVIL DRAWINGSPROP.SYNTHETIC TURFAT BOCCE COURT AREA2L-601PROP.STRING LIGHTSATTACHED TOSTRUCTURE, TYP.14L-602PROP.RAISEDALUMINUM PLANTER2L-601PROP.SEEDEDLAWN, TYP.9L-603PROP.NATIVE WILDFLOWERSEED MIX, TYP.13L-603PROP.STORMWATERBASIN SEED MIX, TYP.7L-6037L-601PROP.(28) BIKE RACKS(56 SPACES), TYP.L B LBLBLBLBPROP.(1) PICNIC TABLEON CONCRETE PAD11L-602PROP.SECURITY BOLLARDS W/SIGNAGE- SEE CIVIL DRAWINGS, TYP.PROP.(8) WASTERECEPTACLE, TYP.5L-601LBLBLBLBPROP.(1) LIGHTBOLLARD10L-602PROP.STABILIZED STONEDUST15L-602B S BSB S B S TTTB S B S TTTTPROP.(6) BUSSING STATION- SEE ARCH DRAWINGSPROP.TRELLIS - SEEARCHITECTURALPROP.PAVILION - SEEARCHITECTURALPROP.CONCRETE CURB -SEE CIVIL DRAWINGSREVISIONSREVDATECOMMENTDRAWN BYCHECKED BY1234567REVISION 7 -01/19/2024CLIENT COMMENTSDTMM02/02/2024CITY COMMENTSDTMM03/04/2024CITY COMMENTSDTMM03/20/2024CITY COMMENTSDT/JKMM04/15/2024CITY AND TDECOMMENTSDTMM05/03/2024ISSUED FORCONSTRUCTIONDTJE/MB06/14/2024ADDENDUM 1DTJE06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORC:\PROGRAMDATA\_BOHLER\C3D2024\TEMP\ACPUBLISH_11952\NYB230191.00-LSCP-0A----->LAYOUT: L-200 MATERIALSDT THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191DT/JKJE/MB11/30/2023NYB230191.00-LSCP-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comM A T THEW J. MRVA002359R E GISTE R E D LANDSCAPE ARCHITECTSTATE OF NEW YOR K EXCELSI OREXP: 06/30/20241"=40'040102040WESSITE PAVINGKEYSYMBOLDESCRIPTIONSEE CIVILCONCRETE PAVINGSTAMPED CONCRETE PAVINGSYNTHETIC TURFSTABILIZED STONE DUST18" WIDE GRAVEL MAINTENANCE STRIPSITE ELEMENTSSTRING LIGHTS FIXED TO STRUCTURELIGHT BOLLARDMOVEABLE PLANTERTIMBER PLATFORMTIMBER PLATFORM WITH SWINGSTAMPED CONCRETE PADTRASH RECEPTACLESSEE ARCHBUSSING STATIONBICYCLE RACKSTIMBER BENCHPICNIC TABLEBOCCE COURTFF&EOUTDOOR SEATINGSEE CIVILSITE SIGNAGESEE CIVILTRASH BIN ENCLOSURETIMBER BOUNDARY FENCEPLANTINGHYDROSEEDED LAWNSTORMWATER BASIN SEED MIXNATIVE WILDFLOWER SEED MIX8+13L-60111L-602T9L-6037L-6039L-6033L-60111L-60314L-60210L-60212L-6024L-6011L-6015L-6017L-6019L-6022L-6011L-601MATERIALS LEGEND15L-60216L-602BSLBLANDSCAPE PLANS TO BE READ INCONJUNCTION WITH NOTES, DETAILSAND SPECIFICATIONSL-200LANDSCAPEMATERIALSPLAN676677 EEEEEEEETTTTWWWWWGGGGGFM FM FM FM FM FM FM FM FM FM FM FM FM SSSC/OSC/OS20' SIDE YARD SETBACK(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO RE M A I N )(TO REMAIN)20' SIDE YARD SETBACK60' FRONT YARD SETBACK TWWWWRIDGELINE RIDGELINERIDGELINESOUTH BROADWAYU.S. ROUTE 9 WETLAND "A"AREA=0.53 ACRES(1) AROGEXISTING TREES TO REMAIN AND TO BEPROTECTED DURING CONSTRUCTIONEXISTING TREES TO REMAIN AND TO BEPROTECTED DURING CONSTRUCTIONT(1) PLO(1) PLO(1) PLO(1) PLO(1) PLO(1) AROG(1) AROG(1) AROG(1) AROG(1) AROG(1) QP(1) QP(1) QP(1) QP(1) BPO(1) PF(1) BPO(1) BPO(3) LL(1) PF(1) SNB(1) BPO(1) PF(1) BPO(3) LL(1) BPO(1) PF(1) SNB(3) LL(1) BPO(1) PF(1) BPO(1) BPO(1) PF(1) BPO(1) SNB(1) ASM(3) LL(1) BPO(1) PF(1) SNB(1) PF(3) LL(1) AROG(1) SNB(1) BPO(3) LL(1) SNB(1) BPO(1) BPO(1) SNB(1) ASM(3) LL(1) BPO(1) PF(1) BPO(3) LL(1) ASM(1) PF(1) BPO(3) LL(1) PF(1) QP(1) QP(1) AROG(1) AROG(1) QP(1) PF(1) BPO(1) SNB(1) QP(1) PF(1) AROG(1) LL(1) PF(1) AROG(1) SNB(1) AROG(3) LL(3) LL(1) BPO(1) BPO(1) QP(1) QP(1) PF(1) ASM(1) PF(3) LL(1) PF(1) BPO(1) ASM(1) PF(1) BPO(1) BPO(1) PF(1) PF(1) SNB(2) LL(1) SNB(1) PF16,650 SF5,650 SF4,600 SF62,300 SF64,400 SF3,900 SF4,050 SF20,500 SF8,800 SF4,450 SF11,000 SF5,850 SFL B LBLBLBLB2,250 SF(1) PLO(1) PLO(1) PLO(1) PLO(1) PLO(1) AROG(1) PLO(1) AROG(1) PLO(1) AROG(1) QP(1) QP(1) QP(1) QP(1) QPLBLBLBLB(1) QP(1) QP(1) QP(3) LL(3) LL(3) LL(3) LL(3) LL(1) AROG(1) AROG(1) AROGB S BSB S B S TTTB S B S TTTTCODEQTYBOTANICAL NAMECOMMON NAMESIZECONTAINERREMARKSCANOPY TREESAROG18ACER RUBRUM `OCTOBERGLORY`OCTOBER GLORY REDMAPLE2.5"-3" CAL.B&BASM6ACER SACCHARUMSUGAR MAPLE2.5"-3" CAL.B&BBPO23BETULA POPULIFOLIAGRAY BIRCH2.5"-3" CAL.B&BMULTI-STEMPLO12PLATANUS OCCIDENTALISAMERICAN SYCAMORE2.5"-3" CAL.B&BQP18QUERCUS PALUSTRISPIN OAK2.5"-3" CAL.B&BSNB11SALIX NIGRABLACK WILLOW2.5"-3" CAL.B&BEVERGREEN TREESLL54LARIX LARICINATAMARACK8-10`B&BPF21PINUS STROBUS 'FASTIGIATA'PYRAMIDAL WHITE PINE8-10`B&BPLANT SCHEDULEREVISIONSREVDATECOMMENTDRAWN BYCHECKED BY1234567REVISION 7 -01/19/2024CLIENT COMMENTSDTMM02/02/2024CITY COMMENTSDTMM03/04/2024CITY COMMENTSDTMM03/20/2024CITY COMMENTSDT/JKMM04/15/2024CITY AND TDECOMMENTSDTMM05/03/2024ISSUED FORCONSTRUCTIONDTJE/MB06/14/2024ADDENDUM 1DTJE06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORC:\PROGRAMDATA\_BOHLER\C3D2024\TEMP\ACPUBLISH_11952\NYB230191.00-LSCP-0A----->LAYOUT: L-300 LANDSCAPEDT THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191DT/JKJE/MB11/30/2023NYB230191.00-LSCP-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comM A T THEW J. MRVA002359R E GISTE R E D LANDSCAPE ARCHITECTSTATE OF NEW YOR K EXCELSI OREXP: 06/30/20241"=40'040102040WES1L-6034L-6036L-6039L-60313L-6037L-603PLANTING LEGENDPLANTINGKEYSYMBOLDESCRIPTIONTREE PLANTINGSHRUB PLANTINGGROUNDCOVER PLANTINGHYDROSEEDED LAWNNATIVE WILDFLOWER SEED MIXBASIN SEED MIXLANDSCAPE PLANS TO BE READ INCONJUNCTION WITH NOTES, DETAILSAND SPECIFICATIONSL-300LANDSCAPEPLANTINGPLAN67677 (2) RAG(6) RAG(3) CO(2) HQ(5) IVH(5) IGC(4) CO(5) MC(5) IVH(11) ROC(13) HQ(7) CO(5) VD(7) CA(13) MC(10) IVH(17) CO(8) IGC(8) CA(20) HQ(12) VD(5) CO(3) IVH(8) IVH(6) CA(5) MC(15) CO(10) SPA(10) IGC(8) CA(10) CO(13) RAG(6) IVH(17) IVH(5) MC(4) MC(2) CA(5) CO(4) HQ(10) CA(4) CO(7) MC(7) IGC(6) CA(30) EPM(30) RTB(30) RTB(30) EPM(23) EPM(29) PS2(41) PS2(26) RTB(41) PS2(26) EPM(1) CA(1) IGC(1) CA(1) IGC(2) HQEEEEEETTTTTTWWWWWWGGGGGGSSSSS60' FRONT YARD SETBACK(2) MC(3) HQ(4) HQ(8) IGC(3) MC(7) RAG(5) CA(9) SPA(4) MC(10) ROC(8) IVH(8) VDEEEEEEEEEEEEEEEEEEEEETTTTTTWWWWWWGGGGGGEETWWWWWWWWWWWW WWW(7) MC(7) CO(3) HQ(11) ROC(5) IGC(1) IVH(1) IVH(3) IGC(1) IVH(5) HQ(8) IGC(7) IVH(8) MC(6) IGC(7) IVH(3) IGC(10) IVH(16) IGCCODEQTYBOTANICAL NAMECOMMON NAMESIZECONTAINERREMARKSPLANT SCHEDULESHRUBSCA58CLETHRA ALNIFOLIASUMMERSWEET CLETHRA24-30"CONTAINERCO77CEPHALANTHUSOCCIDENTALISBUTTONBUSH24-30"CONTAINERHQ66HYDRANGEA QUERCIFOLIAOAKLEAF HYDRANGEA36-42"CONTAINERIGC92ILEX GLABRA `COMPACTA`COMPACT INKBERRY24-30"CONTAINERIVH89ITEA VIRGINICA `HENRY`SGARNET`HENRY`S GARNETSWEETSPIRE24-30"CONTAINERMC63MORELLA CAROLINIENSISBAYBERRY24-30"CONTAINERRAG28RHUS AROMATICA `GRO-LOW`GRO-LOW FRAGRANTSUMAC15-18"CONTAINERROC32ROSA CAROLINACAROLINA ROSE18-24"CONTAINERSPA19SPIRAEA ALBAMEADOWSWEET15-18"CONTAINERVD25VIBURNUM DENTATUMVIBURNUM30-42"CONTAINERCODEQTYBOTANICAL NAMECOMMON NAMESIZECONTAINERSPACINGREMARKSORNAMENTAL GRASSESPS2111PANICUM VIRGATUM'SHENANDOAH'SHENANDOAH SWITCHGRASS1 GAL.CONTAINER18" o.c.PERENNIALSEPM109ECHINACEA PURPUREA'MAGNUS'MAGNUS PURPLECONEFLOWER1 GAL.CONTAINER18" o.c.RTB86RUDBECKIA TRILOBABROWN EYED SUSAN2 GAL.CONTAINER18" o.c.REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY1234567REVISION 7 -01/19/2024CLIENT COMMENTSDTMM02/02/2024CITY COMMENTSDTMM03/04/2024CITY COMMENTSDTMM03/20/2024CITY COMMENTSDT/JKMM04/15/2024CITY AND TDECOMMENTSDTMM05/03/2024ISSUED FORCONSTRUCTIONDTJE/MB06/14/2024ADDENDUM 1DTJE06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORC:\PROGRAMDATA\_BOHLER\C3D2024\TEMP\ACPUBLISH_11952\NYB230191.00-LSCP-0A----->LAYOUT: L-301 LANDSCAPEDT THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191DT/JKJE/MB11/30/2023NYB230191.00-LSCP-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comM A T THEW J. MRVA002359R E GISTE R E D LANDSCAPE ARCHITECTSTATE OF NEW YOR K EXCELSI OREXP: 06/30/20241"=10'0102.5510Scale: 1"=10'TAPROOM SCREEN PLANTING1Scale: 1"=10'TAPROOM ENTRY PLANTING21L-6034L-6036L-6039L-60313L-6037L-603PLANTING LEGENDPLANTINGKEYSYMBOLDESCRIPTIONTREE PLANTINGSHRUB PLANTINGGROUNDCOVER PLANTINGHYDROSEEDED LAWNNATIVE WILDFLOWER SEED MIXBASIN SEED MIXLANDSCAPE PLANS TO BE READ INCONJUNCTION WITH NOTES, DETAILSAND SPECIFICATIONSScale: 1"=10'TO GO SCREEN PLANTING4Scale: 1"=10'LOADING DOCK SCREEN PLANTING3L-301LANDSCAPEPLANTINGENLARGEMENTS676676 EEEEEEEETTTTC/OSC/OS20' SIDE YARD SETBACK(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO REMAIN)(TO RE M A I N )(TO REMAIN)20' SIDE YARD SETBACK60' FRONT YARD SETBACK TRIDGELINE RIDGELINERIDGELINESOUTH BROADWAYU.S. ROUTE 9 WETLAND "A"AREA=0.53 ACRESTL B LBLBLBLBLBLBLBLBB S BSB S B S TTTB S B S TTTTREVISIONSREVDATECOMMENTDRAWN BYCHECKED BY1234567REVISION 7 -01/19/2024CLIENT COMMENTSDTMM02/02/2024CITY COMMENTSDTMM03/04/2024CITY COMMENTSDTMM03/20/2024CITY COMMENTSDT/JKMM04/15/2024CITY AND TDECOMMENTSDTMM05/03/2024ISSUED FORCONSTRUCTIONDTJE/MB06/14/2024ADDENDUM 1DTJE06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORC:\PROGRAMDATA\_BOHLER\C3D2024\TEMP\ACPUBLISH_11952\NYB230191.00-LSCP-0A----->LAYOUT: L-400 IRRIGATIONDT THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191DT/JKJE/MB11/30/2023NYB230191.00-LSCP-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comM A T THEW J. MRVA002359R E GISTE R E D LANDSCAPE ARCHITECTSTATE OF NEW YOR K EXCELSI OREXP: 06/30/20241"=40'040102040WESIRRIGATION LEGENDIRRIGATION ELEMENTSSYMBOLDESCRIPTIONDRIP IRRIGATIONSPRAY IRRIGATIONIRRIGATION SLEEVELANDSCAPE PLANS TO BE READ INCONJUNCTION WITH NOTES, DETAILSAND SPECIFICATIONSL-400IRRIGATIONPLAN66 COVERED PATIO - SEE ARCHITECTURALPLANTED BERM27'CONCRETEPATH8'TAPROOM "EV"PARKINGDRIVEWAYPAVILION - SEE ARCHITECTURALPLANTED SWALE31.5'TRELLIS - SEE ARCHITECTURALOPEN LAWN AREATIMBER SWING8'PLANTED BERM15'CONCRETEPATH5'TAPROOMPARKINGSTAMPED CONCRETE PATIORAISEDPLANTERS5'RAISEDPLANTERS5'STAMPEDCONCRETEPATH9'STAMPED CONCRETE PATIO10',MIN.REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY1234567REVISION 7 -01/19/2024CLIENT COMMENTSDTMM02/02/2024CITY COMMENTSDTMM03/04/2024CITY COMMENTSDTMM03/20/2024CITY COMMENTSDT/JKMM04/15/2024CITY AND TDECOMMENTSDTMM05/03/2024ISSUED FORCONSTRUCTIONDTJE/MB06/14/2024ADDENDUM 1DTJE06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORC:\PROGRAMDATA\_BOHLER\C3D2024\TEMP\ACPUBLISH_11952\NYB230191.00-LSCP-0A----->LAYOUT: L-500 SECTIONSDT THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191DT/JKJE/MB11/30/2023NYB230191.00-LSCP-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comM A T THEW J. MRVA002359R E GISTE R E D LANDSCAPE ARCHITECTSTATE OF NEW YOR K EXCELSI OREXP: 06/30/20241"=10'0102.5510LANDSCAPE PLANS TO BE READ INCONJUNCTION WITH NOTES, DETAILSAND SPECIFICATIONSScale: 1"=10'LANDSCAPE SECTION AT PAVILION AND TRELLIS2Scale: 1"=10'LANDSCAPE SECTION AT LANDSCAPE BERM1L-500LANDSCAPESECTIONS REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY1234567REVISION 7 -01/19/2024CLIENT COMMENTSDTMM02/02/2024CITY COMMENTSDTMM03/04/2024CITY COMMENTSDTMM03/20/2024CITY COMMENTSDT/JKMM04/15/2024CITY AND TDECOMMENTSDTMM05/03/2024ISSUED FORCONSTRUCTIONDTJE/MB06/14/2024ADDENDUM 1DTJE06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORC:\PROGRAMDATA\_BOHLER\C3D2024\TEMP\ACPUBLISH_11952\NYB230191.00-LSCP-0A----->LAYOUT: L-600 NOTESDT THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191DT/JKJE/MB11/30/2023NYB230191.00-LSCP-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comM A T THEW J. MRVA002359R E GISTE R E D LANDSCAPE ARCHITECTSTATE OF NEW YOR K EXCELSI OREXP: 06/30/2024ABBREVIATIONSKEYDESCRIPTIONARCHARCHITECTBCBACK OF CURBBMBENCHMARKBOCBOTTOM OF CURBBWBOTTOM OF WALLBLDGBUILDINGCONC.CONCRETEDECDECORATIVE°DEGREEDEPDEPRESSEDØ / DIADIAMETERDMHDRAIN MANHOLEDIPDUCTILE IRON PIPEEOPEDGE OF PAVEMENTELEVELEVATIONEXIST.EXISTINGFFFINISH FLOORFFEFINISH FLOOR ELEVATIONGCGENERAL CONTRACTORGRTGRATEHDPEHIGH DENSITY POLYETHYLENE PIPEHPHIGH POINTINTINTERSECTIONINVINVERTL.S.A.LANDSCAPE AREALODLIMIT OF DISTURBANCELOWLIMIT OF WORKLFLINEAR FOOT / FEETLPLOW POINTMAXMAXIMUMMEPMECHANICAL, ELECTRICAL,PLUMBINGMEMEET OR MATCH EXISTINGMINMINIMUMNo. / #NUMBER±PLUS OR MINUSPCPOINT OF CURVATUREPIPOINT OF INTERSECTIONPTPOINT OF TANGENCYPVIPOINT OF VERTICAL INTERSECTIONPVCPOLYVINYL CHLORIDE PIPEPROP.PROPOSEDRRADIUS OR RADIIRCPREINFORCED CONCRETE PIPER.O.W.RIGHT-OF-WAYSANSANITARYSMHSEWER MANHOLESSLOPESFSQUARE FOOTSTASTATIONSTMSTORMTBRTO BE REMOVEDTBR/RTO BE REMOVED AND REPLACEDTCTOP OF CURBTWTOP OF WALLTPFTREE PROTECTION FENCETYP.TYPICALUNGUNDERGROUNDV.I.F.VERIFY IN FIELDWWIDTHGENERAL1.THE LANDSCAPE CONTRACTOR SHALL BE REQUIRED TO PERFORM ALL CLEARING, FINISHED GRADING, SOILPREPARATION, PERMANENT SEEDING OR SODDING, PLANTING AND MULCHING INCLUDING ALL LABOR,MATERIALS, TOOLS AND EQUIPMENT NECESSARY FOR THE COMPLETION OF THIS PROJECT, UNLESSOTHERWISE CONTRACTED BY THE GENERAL CONTRACTOR.2.THESE PLANS ARE SOLELY BASED ON INFORMATION THE OWNER AND OTHERS PROVIDED TO BOHLERENGINEERING, (HEREIN “BOHLER”) PRIOR TO THE DATE ON WHICH THE ENGINEER OF RECORD AND BOHLERPREPARED THESE PLANS. THE CONTRACTOR MUST FIELD VERIFY ALL EXISTING CONDITIONS AND IMMEDIATELYNOTIFY BOHLER , IN WRITING, IF ANY ACTUAL SITE CONDITIONS DIFFER FROM THOSE SHOWN ON THESE PLANS,OR IF THE PROPOSED WORK CONFLICTS WITH ANY OTHER SITE FEATURES.3.SYMBOLS AND LEGENDS OF PROJECT FEATURES ARE GRAPHIC REPRESENTATIONS AND ARE NOTNECESSARILY SHOWN ON THE DRAWINGS TO SCALE OR TO THEIR ACTUAL DIMENSION OR LOCATION.COORDINATE DETAIL SHEET DIMENSIONS, MANUFACTURERS' LITERATURE, SHOP DRAWINGS AND FIELDMEASUREMENTS OF SUPPLIED PRODUCTS FOR LAYOUT OF THE PROJECT FEATURES.4.DO NOT RELY SOLELY ON ELECTRONIC VERSIONS OF DRAWINGS, SPECIFICATIONS, AND DATA FILES THAT AREPROVIDED BY THE ENGINEER. FIELD VERIFY LOCATION OF PROJECT FEATURES.5.PERFORM NECESSARY CONSTRUCTION NOTIFICATIONS, APPLY FOR AND OBTAIN NECESSARY PERMITS, PAYFEES, AND POST BONDS ASSOCIATED WITH THE WORK AS REQUIRED BY THE CONTRACT DOCUMENTS.6.SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS OF BUILDINGS AND ADJACENT SITE ELEMENTS INCLUDINGSIDEWALKS, RAMPS, BUILDING ENTRANCES, STAIRWAYS, UTILITY PENETRATIONS, CONCRETE DOOR PADS,COMPACTOR PAD, LOADING DOCKS, BOLLARDS, ETC.7.LOCATION OF UTILITIES SHOWN HEREON ARE THE RESULT OF SURFACE EVIDENCE AS LOCATED BY FIELDSURVEY, PLANS OF RECORD, INFORMATION FURNISHED BY THE RESPECTIVE UTILITY COMPANIES, AND OTHERAVAILABLE SOURCES. THIS PLAN DOES NOT NECESSARILY DEPICT THE EXACT LOCATION OF ALL UTILITIESWHICH MAY EXIST AT THIS TIME WITHIN THE PREMISES SURVEYED. LOCATIONS SHOULD BE VERIFIED BY THERESPECTIVE UTILITY COMPANY BEFORE BEING RELIED UPON. ALL FIELD CHANGES MUST BE APPROVED BY THEENGINEER.8.CONTRACTOR TO UTILIZE WORKMANLIKE INDUSTRY STANDARDS IN PERFORMING ALL LANDSCAPECONSTRUCTION. THE SITE IS TO BE LEFT IN A CLEAN STATE AT THE END OF EACH WORKDAY. ALL DEBRIS,MATERIALS AND TOOLS SHALL BE PROPERLY STORED, STOCKPILED OR DISPOSED OF.9.WASTE MATERIALS AND DEBRIS SHALL BE COMPLETELY DISPOSED OF AT THE CONTRACTOR'S EXPENSE.DEBRIS SHALL NOT BE BURIED, INCLUDING ORGANIC MATERIALS, BUT SHALL BE REMOVED COMPLETELY FROMTHE SITE.10.BEFORE AND DURING PRELIMINARY GRADING AND FINISHED GRADING, ALL WEEDS AND GRASSES SHALL BEDUG OUT BY THE ROOTS AND DISPOSED OF IN ACCORDANCE WITH GENERAL WORK PROCEDURES OUTLINEDHEREIN.11.ALL EXISTING TREES TO REMAIN SHALL BE PRUNED TO REMOVE ANY DAMAGED BRANCHES. THE ENTIRE LIMBOF ANY DAMAGED BRANCH SHALL BE CUT OFF AT THE BRANCH COLLAR. CONTRACTOR SHALL ENSURE THATCUTS ARE SMOOTH AND STRAIGHT. ANY EXPOSED ROOTS SHALL BE CUT BACK WITH CLEAN, SHARP TOOLSAND TOPSOIL SHALL BE PLACED AROUND THE REMAINDER OF THE ROOTS. EXISTING TREES SHALL BEMONITORED ON A REGULAR BASIS FOR ADDITIONAL ROOT OR BRANCH DAMAGE AS A RESULT OFCONSTRUCTION. ROOTS SHALL NOT BE LEFT EXPOSED FOR MORE THAN ONE (1) DAY. CONTRACTOR SHALLWATER EXISTING TREES AS NEEDED TO PREVENT SHOCK OR DECLINE.12.CONTRACTOR SHALL ARRANGE TO HAVE A UTILITY STAKE-OUT TO LOCATE ALL UNDERGROUND UTILITIES PRIORTO INSTALLATION OF ANY LANDSCAPE MATERIAL. UTILITY COMPANIES SHALL BE CONTACTED THREE (3) DAYSPRIOR TO THE BEGINNING OF WORK.EARTHWORK1.UNLESS OTHERWISE CONTRACTED, THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR THEINSTALLATION OF TOPSOIL AND THE ESTABLISHMENT OF FINE-GRADING WITHIN THE DISTURBANCE AREA OFTHE SITE.2.LANDSCAPE CONTRACTOR SHALL VERIFY THAT SUBGRADE FOR INSTALLATION OF TOPSOIL HAS BEENESTABLISHED. THE SUBGRADE OF THE SITE MUST MEET THE FINISHED GRADE LESS THE REQUIRED TOPSOILTHICKNESS (1"±).3.ALL LAWN AND PLANTING AREAS SHALL BE GRADED TO A SMOOTH, EVEN AND UNIFORM PLANE WITH NOABRUPT CHANGE OF SURFACE AS DEPICTED WITHIN THIS SET OF CONSTRUCTION PLANS, UNLESS OTHERWISEDIRECTED BY THE PROJECT ENGINEER OR LANDSCAPE ARCHITECT.4.ALL PLANTING AREAS SHALL BE GRADED AND MAINTAINED TO ALLOW FREE FLOW OF SURFACE WATER IN ANDAROUND THE PLANTING BEDS. STANDING WATER SHALL NOT BE PERMITTED IN PLANTING BEDS.LAYOUT1.THE SITE PLAN IS BASED ON EXISTING CONDITIONS INFORMATION PROVIDED BY OTHERS. BOHLERENGINEERING IS NOT RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THIS INFORMATION.2.THE CONTRACTOR SHALL VERIFY ALL CONDITIONS IN THE FIELD AND REPORT ANY AND ALL DISCREPANCIES TOTHE OWNER'S REPRESENTATIVE. ANY ALTERATIONS TO THESE DRAWINGS MADE IN THE FIELD SHALL BEPROMPTLY REPORTED BY THE CONTRACTOR TO THE OWNER'S REPRESENTATIVE AND RECORDED ON RECORDDRAWINGS.3.ALL LINES AND DIMENSIONS ARE PARALLEL OR PERPENDICULAR TO THE LINES FROM WHICH THEY AREMEASURED UNLESS OTHERWISE INDICATED.4.DIMENSIONS ARE APPROXIMATE BASED ON TAKE OFF FROM SURVEY. ACTUAL DIMENSIONS MAY VARY. NOTIFYTHE OWNER'S REPRESENTATIVE IN THE EVENT OF DIMENSIONAL DISCREPANCIES.5.THE CONTRACTOR TO STAKE OUT LAYOUT FOR APPROVAL PRIOR TO EXCAVATION.6.LANDSCAPE LAYOUT DRAWINGS ARE NOT TO BE USED FOR LAYOUT OF ANY BUILDINGS ON THE SITE.7.PROVIDE PROPER TRANSITIONS BETWEEN EXISTING AND PROPOSED SITE IMPROVEMENTS. FIELD VERIFYEXISTING PAVEMENT AND GROUND ELEVATIONS AT THE INTERFACE WITH PROPOSED PAVEMENTS ANDDRAINAGE STRUCTURES BEFORE START OF CONSTRUCTION.8.PRIOR TO ORDERING MATERIALS AND BEGINNING CONSTRUCTION, FIELD VERIFY PROPOSED UTILITY ROUTESAND IDENTIFY ANY INTERFERENCES OR OBSTRUCTIONS WITH EXISTING UTILITIES OR PUBLIC RIGHTS-OF-WAY.9.DIMENSIONS ARE FROM FACE OF CURB, FACE OF BUILDING, FACE OF WALL, AND CENTER LINE OF PAVEMENTMARKINGS, UNLESS NOTED OTHERWISE.10.BOUNDS OR MONUMENTATION DISTURBED DURING CONSTRUCTION SHALL BE SET OR RESET BY APROFESSIONAL LICENSED SURVEYOR.11.CONTRACTOR SHALL BE RESPONSIBLE FOR THE MAINTENANCE AND SAFETY OF TRAFFIC ON THE PUBLIC ANDPRIVATE WAYS AFFECTED BY THE CONSTRUCTION OF THIS PROJECT.12.CONSTRUCT ACCESSIBLE ROUTES, PARKING SPACES, RAMPS, SIDEWALKS AND WALKWAYS IN CONFORMANCEWITH THE FEDERAL AMERICANS WITH DISABILITIES ACT AND WITH NEW YORK ARCHITECTURAL ACCESS BOARDAND LOCAL LAWS AND REGULATIONS (WHICHEVER ARE MORE STRINGENT).PAVING1.ALL HARDSCAPE MATERIALS SHALL MEET LANDSCAPE SPECIFICATIONS AND MEET OR EXCEED STATEDEPARTMENT OF TRANSPORTATION'S SPECIFICATIONS AT A MINIMUM.2.ALL PAVED AREAS TO MEET ACCESSIBILITY STANDARDS.3.ALL FINISHES AS PER AGREED SAMPLES.4.FORM ALL JOINTS / SAWCUTS WITHIN 24 HOURS AFTER POUR OR THEREAFTER TO ENSURE SAWCUTS AREFORMED WITHOUT CHIPPING OR SPALLING.5.THE CONTRACTOR SHALL REVIEW ALL DRAWINGS AND SPECIFICATIONS TO DETERMINE THE TOTAL SCOPE OFWORK AND ALL REQUIRED COORDINATION.6.CONTRACTOR SHALL VERIFY ALL EXISTING UTILITY LOCATIONS PRIOR TO EXCAVATION.7.CONTRACTOR SHALL PREPARE SUBMITTALS TO THE LANDSCAPE ARCHITECT FOR ALL COMPONENTS OF THEFINISHED WORK, INCLUDING SHOP DRAWINGS, PRODUCT DATA, MATERIAL CERTIFICATIONS, MIX DESIGNS ANDSAMPLES.8.THE DIMENSIONS OF PAVEMENT JOINTS AS SHOWN ON THE DRAWINGS ARE TO THE CENTER LINE OF EACHTYPE OF JOINT EXCEPT WHERE PAVEMENT MEETS A VERTICAL FACE; AT THIS LOCATION DIMENSIONS ARE TOTHE VERTICAL FACE. THE DIMENSIONS SHOWN ON DRAWINGS SHOW DESIGN INTENT AND MUST BE FIELDVERIFIED PRIOR TO PREPARATION OF SHOP DRAWINGS.9.THE CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGE INSIDE OR OUTSIDE OF LIMIT OF WORK LINE DUE TOCONSTRUCTION OPERATIONS.10.STORAGE AREAS FOR THE GENERAL CONTRACTOR'S EQUIPMENT AND MATERIALS SHALL BE LOCATED WITHINTHE LIMITS OF WORK AS APPROVED BY THE SITE REPRESENTATIVE.11.WHERE NEW PAVING MEETS EXISTING PAVING, MEET LINE AND GRADE OF EXISTING SMOOTHLY WITH NEWCONSTRUCTION.12.AT ALL LOCATIONS WHERE EXISTING BITUMINOUS CONCRETE PAVEMENT ABUTS NEW CONSTRUCTION, THEEDGE OF THE EXISTING PAVEMENT SHALL BE SAWCUT TO A CLEAN SMOOTH EDGE.FERTILIZER1.FERTILIZER SHALL BE DELIVERED TO THE SITE MIXED AS SPECIFIED IN THE ORIGINAL UNOPENED STANDARDBAGS SHOWING WEIGHT, ANALYSIS AND NAME OF MANUFACTURER. FERTILIZER SHALL BE STORED IN AWEATHERPROOF PLACE SO THAT IT CAN BE KEPT DRY PRIOR TO USE.2.FOR THE PURPOSE OF BIDDING, ASSUME THAT FERTILIZER SHALL BE 10% NITROGEN, 6% PHOSPHORUS AND 4%POTASSIUM BY WEIGHT. A FERTILIZER SHOULD NOT BE SELECTED WITHOUT A SOIL TEST PERFORMED BY ACERTIFIED SOIL LABORATORY.PLANT MATERIAL1.ALL PLANTS SHALL IN ALL CASES CONFORM TO THE REQUIREMENTS OF THE "AMERICAN STANDARD FORNURSERY STOCK" (ANSI Z60.1), LATEST EDITION, AS PUBLISHED BY THE AMERICAN NURSERY & LANDSCAPEASSOCIATION (FORMERLY THE AMERICAN ASSOCIATION OF NURSERYMEN).2.IN ALL CASES, BOTANICAL NAMES SHALL TAKE PRECEDENCE OVER COMMON NAMES FOR ANY AND ALL PLANTMATERIAL.3.PLANTS SHALL BE LEGIBLY TAGGED WITH THE PROPER NAME AND SIZE. TAGS ARE TO REMAIN ON AT LEASTONE PLANT OF EACH SPECIES FOR VERIFICATION PURPOSES DURING THE FINAL INSPECTION.4.TREES WITH ABRASION OF THE BARK, SUN SCALDS, DISFIGURATION OR FRESH CUTS OF LIMBS OVER 1¼",WHICH HAVE NOT BEEN COMPLETELY CALLUSED, SHALL BE REJECTED. PLANTS SHALL NOT BE BOUND WITHWIRE OR ROPE AT ANY TIME SO AS TO DAMAGE THE BARK OR BREAK BRANCHES.5.ALL PLANTS SHALL BE TYPICAL OF THEIR SPECIES OR VARIETY AND SHALL HAVE A NORMAL HABIT OF GROWTH:WELL DEVELOPED BRANCHES, DENSELY FOLIATED, VIGOROUS ROOT SYSTEMS AND BE FREE OF DISEASE,INSECTS, PESTS, EGGS OR LARVAE.6.CALIPER MEASUREMENTS OF NURSERY GROWN TREES SHALL BE TAKEN AT A POINT ON THE TRUNK SIX INCHES(6") ABOVE THE NATURAL GRADE FOR TREES UP TO AND INCLUDING A FOUR INCH (4") CALIPER SIZE. IF THECALIPER AT SIX INCHES (6") ABOVE THE GROUND EXCEEDS FOUR INCHES (4") IN CALIPER, THE CALIPER SHOULDBE MEASURED AT A POINT 12" ABOVE THE NATURAL GRADE.7.SHRUBS SHALL BE MEASURED TO THE AVERAGE HEIGHT OR SPREAD OF THE SHRUB, AND NOT TO THELONGEST BRANCH.8.TREES AND SHRUBS SHALL BE HANDLED WITH CARE BY THE ROOT BALL.TREE PROTECTION1.CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING TREES TO REMAIN. A TREEPROTECTION ZONE SHALL BE ESTABLISHED AT THE DRIP LINE OR AT THE LIMIT OF CONSTRUCTIONDISTURBANCE, WHICHEVER IS GREATER. LOCAL STANDARDS THAT MAY REQUIRE A MORE STRICT TREEPROTECTION ZONE SHALL BE HONORED.2.A FORTY-EIGHT INCH (48") HIGH WOODEN SNOW FENCE OR ORANGE COLORED HIGH-DENSITY 'VISI-FENCE', ORAPPROVED EQUAL, MOUNTED ON STEEL POSTS SHALL BE PLACED ALONG THE BOUNDARY OF THE TREEPROTECTION ZONE. POSTS SHALL BE LOCATED AT A MAXIMUM OF EIGHT FEET (8') ON CENTER OR ASINDICATED WITHIN THE TREE PROTECTION DETAIL.3.WHEN THE TREE PROTECTION FENCING HAS BEEN INSTALLED, IT SHALL BE INSPECTED BY THE APPROVINGAGENCY PRIOR TO DEMOLITION, GRADING, TREE CLEARING OR ANY OTHER CONSTRUCTION. THE FENCINGALONG THE TREE PROTECTION ZONE SHALL BE REGULARLY INSPECTED BY THE LANDSCAPE CONTRACTOR ANDMAINTAINED UNTIL ALL CONSTRUCTION ACTIVITY HAS BEEN COMPLETED.4.EVERY EFFORT SHALL BE TAKEN TO PRESERVE THE HEALTH OF EXISTING VEGETATION TO REMAIN ON SITE.TREE PROTECTION MEASURES SHALL BE INSTALLED PER CONSTRUCTION DRAWINGS BEFORE ANYCONSTRUCTION ACTIVITY IS TO TAKE PLACE. TREE PROTECTION SHALL REMAIN INTACT THROUGHOUT THEDURATION OF THE PROJECT. ALL TREE PROTECTION SHALL BE REMOVED UPON PROJECT CLOSEOUT.5.THE CRITICAL ROOT ZONE OF AN EXISTING TREE TO REMAIN IS DEFINED AS A CIRCLE WHOSE CENTER IS THECENTER OF THE TREE TRUNK AND WHOSE RADIUS IS EQUAL TO THE TREE'S DIAMETER AT BREAST-HEIGHT(DBH) IN INCHES TIMES 12".6.NO WORK, EQUIPMENT STORAGE, OR STOCKPILING OR DISPOSAL OF MATERIALS SHALL TAKE PLACE WITHINTHE CRITICAL ROOT ZONE OF AN EXISTING TREE TO REMAIN UNLESS OTHERWISE CALLED OUT ON THE PLANS.7.TREE REMOVAL SCOPE SHALL INCLUDE THE FELLING, CUTTING, AND SATISFACTORY DISPOSAL OF ALL TREES,STUMPS AND VEGETATIVE DEBRIS PRODUCED THROUGH THE CLEARING OPERATIONS.8.FELL TREES IN SUCH A WAY AS TO NOT INJURE TREES TO BE SAVED. EXCAVATION OR GRADING WITHIN THEBRANCH SPREAD OF TREES TO BE SAVED SHALL BE PERFORMED ONLY UNDER THE DIRECTION OF THEOWNER'S REPRESENTATIVE UNLESS OTHERWISE DIRECTED.9.STUMPS TO BE REMOVED SHALL BE GRUBBED TO THEIR FULL DEPTH. STUMPS SHALL BE LEGALLY DISPOSED OFOFF-SITE.10.CONTRACTOR SHALL TAG ALL TREES TO BE REMOVED AND VERIFY WITH OWNER'S REPRESENTATIVE PRIOR TOTHE START OF DEMOLITION.11.ALL EXISTING TREES TO BE PROTECTED SHALL BE PRUNED BY A CERTIFIED ARBORIST TO REMOVE DEAD ORDYING BRANCHES, IMPROVE STRUCTURE, AND PROVIDE 10' MINIMUM CLEARANCE BELOW BRANCHES UNLESSOTHERWISE NOTED.SOIL MODIFICATIONS1.CONTRACTOR SHALL ATTAIN A SOIL TEST FOR ALL AREAS OF THE SITE PRIOR TO CONDUCTING ANY PLANTING.SOIL TESTS SHALL BE PERFORMED BY A CERTIFIED SOIL LABORATORY.2.LANDSCAPE CONTRACTOR SHALL REPORT ANY SOIL OR DRAINAGE CONDITIONS CONSIDERED DETRIMENTAL TOTHE GROWTH OF PLANT MATERIAL. SOIL MODIFICATIONS, AS SPECIFIED HEREIN, MAY NEED TO BE CONDUCTEDBY THE LANDSCAPE CONTRACTOR DEPENDING ON SITE CONDITIONS.3.THE FOLLOWING AMENDMENTS AND QUANTITIES ARE APPROXIMATE AND ARE FOR BIDDING PURPOSES ONLY.COMPOSITION OF AMENDMENTS SHOULD BE REVISED DEPENDING ON THE OUTCOME OF A TOPSOIL ANALYSISPERFORMED BY A CERTIFIED SOIL LABORATORY.3.1.TO INCREASE A SANDY SOIL'S ABILITY TO RETAIN WATER AND NUTRIENTS, THOROUGHLY TILL ORGANICMATTER INTO THE TOP 6-12". USE COMPOSTED BARK, COMPOSTED LEAF MULCH OR PEAT MOSS. ALLPRODUCTS SHOULD BE COMPOSTED TO A DARK COLOR AND BE FREE OF PIECES WITH IDENTIFIABLE LEAFOR WOOD STRUCTURE. AVOID MATERIAL WITH A PH HIGHER THAN 7.5.3.2.TO INCREASE DRAINAGE, MODIFY HEAVY CLAY OR SILT (MORE THAN 40% CLAY OR SILT) BY ADDINGCOMPOSTED PINE BARK (UP TO 30% BY VOLUME) AND/OR AGRICULTURAL GYPSUM. COARSE SAND MAY BEUSED IF ENOUGH IS ADDED TO BRING THE SAND CONTENT TO MORE THAN 60% OF THE TOTAL MIX.SUBSURFACE DRAINAGE LINES MAY NEED TO BE ADDED TO INCREASE DRAINAGE.3.3.MODIFY EXTREMELY SANDY SOILS (MORE THAN 85%) BY ADDING ORGANIC MATTER AND/OR DRY,SHREDDED CLAY LOAM UP TO 30% OF THE TOTAL MIX.TOPSOILING1.CONTRACTOR SHALL PROVIDE A 6" THICK MINIMUM LAYER OF TOPSOIL, OR AS DIRECTED BY THE LOCALORDINANCE OR CLIENT, IN ALL PLANTING AREAS. TOPSOIL SHOULD BE SPREAD OVER A PREPARED SURFACE INA UNIFORM LAYER TO ACHIEVE THE DESIRED COMPACTED THICKNESS.2.ON-SITE TOPSOIL MAY BE USED TO SUPPLEMENT THE TOTAL AMOUNT REQUIRED. TOPSOIL FROM THE SITE MAYBE REJECTED IF IT HAS NOT BEEN PROPERLY REMOVED, STORED AND PROTECTED PRIOR TO CONSTRUCTION.3.CONTRACTOR SHALL FURNISH TO THE APPROVING AGENCY AN ANALYSIS OF BOTH IMPORTED AND ON-SITETOPSOIL TO BE UTILIZED IN ALL PLANTING AREAS. THE PH AND NUTRIENT LEVELS MAY NEED TO BE ADJUSTEDTHROUGH SOIL MODIFICATIONS AS NEEDED TO ACHIEVE THE REQUIRED LEVELS AS SPECIFIED IN THEMATERIALS SECTION ABOVE.4.ALL LAWN AREAS ARE TO BE CULTIVATED TO A DEPTH OF SIX INCHES (6"). ALL DEBRIS EXPOSED FROMEXCAVATION AND CULTIVATION SHALL BE DISPOSED OF IN ACCORDANCE WITH GENERAL WORK PROCEDURESSECTION ABOVE. THE FOLLOWING SHALL BE TILLED INTO THE TOP FOUR INCHES (4") IN TWO DIRECTIONS(QUANTITIES BASED ON A 1,000 SQUARE FOOT AREA - FOR BID PURPOSES ONLY [SEE SPECIFICATION 6.A.]):4.1.20 POUNDS 'GRO-POWER' OR APPROVED SOIL CONDITIONER/FERTILIZER4.2.20 POUNDS NITRO-FORM (COURSE) 38-0-0 BLUE CHIP OR APPROVED NITROGEN FERTILIZER5.THE SPREADING OF TOPSOIL SHALL NOT BE CONDUCTED UNDER MUDDY OR FROZEN CONDITIONS.PLANTING1.INSOFAR THAT IT IS FEASIBLE, PLANT MATERIAL SHALL BE PLANTED ON THE DAY OF DELIVERY. IN THE EVENTTHAT THIS IS NOT POSSIBLE, LANDSCAPE CONTRACTOR SHALL PROTECT UNINSTALLED PLANT MATERIAL.PLANTS SHALL NOT REMAIN UNPLANTED FOR LONGER THAN A THREE DAY PERIOD AFTER DELIVERY. PLANTSTHAT WILL NOT BE PLANTED FOR A PERIOD OF TIME GREATER THAN THREE DAYS SHALL BE HEALED IN WITHTOPSOIL OR MULCH TO HELP PRESERVE ROOT MOISTURE.2.PLANTING OPERATIONS SHALL BE PERFORMED DURING PERIODS WITHIN THE PLANTING SEASON WHENWEATHER AND SOIL CONDITIONS ARE SUITABLE AND IN ACCORDANCE WITH ACCEPTED LOCAL PRACTICE.PLANTS SHALL NOT BE INSTALLED IN TOPSOIL THAT IS IN A MUDDY OR FROZEN CONDITION.3.ANY INJURED ROOTS OR BRANCHES SHALL BE PRUNED TO MAKE CLEAN-CUT ENDS PRIOR TO PLANTINGUTILIZING CLEAN, SHARP TOOLS. ONLY INJURED OR DISEASED BRANCHING SHALL BE REMOVED.4.ALL PLANTING CONTAINERS, BASKETS AND NON-BIODEGRADABLE MATERIALS SHALL BE REMOVED FROM ROOTBALLS DURING PLANTING. NATURAL FIBER BURLAP MUST BE CUT FROM AROUND THE TRUNK OF THE TREE ANDFOLDED DOWN AGAINST THE ROOT BALL PRIOR TO BACKFILLING.5.POSITION TREES AND SHRUBS AT THEIR INTENDED LOCATIONS AS PER THE PLANS AND SECURE THEAPPROVAL OF THE LANDSCAPE ARCHITECT PRIOR TO EXCAVATING PITS, MAKING NECESSARY ADJUSTMENTSAS DIRECTED.6.PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY, THE PROPOSED LANDSCAPE, AS SHOWN ONTHE APPROVED LANDSCAPE PLAN, MUST BE INSTALLED, INSPECTED AND APPROVED BY THE APPROVINGAGENCY. THE APPROVING AGENCY SHALL TAKE INTO ACCOUNT SEASONAL CONSIDERATIONS IN THIS REGARDAS FOLLOWS. THE PLANTING OF TREES, SHRUBS, VINES OR GROUND COVER SHALL OCCUR ONLY DURING THEFOLLOWING PLANTING SEASONS:6.1.PLANTS: MARCH 15 TO DECEMBER 156.2.LAWN: MARCH 15 TO JUNE 15 OR SEPT. 1 TO DECEMBER 16.3.PLANTINGS REQUIRED FOR A CERTIFICATE OF OCCUPANCY SHALL BE PROVIDED DURING THE NEXTAPPROPRIATE SEASON AT THE MUNICIPALITY'S DISCRETION. CONTRACTOR SHOULD CONTACT APPROVINGAGENCY FOR POTENTIAL SUBSTITUTIONS.7.FURTHERMORE, THE FOLLOWING TREE VARIETIES ARE UNUSUALLY SUSCEPTIBLE TO WINTER DAMAGE. WITHTRANSPLANT SHOCK AND THE SEASONAL LACK OF NITROGEN AVAILABILITY, THE RISK OF PLANT DEATH ISGREATLY INCREASED. IT IS NOT RECOMMENDED THAT THESE SPECIES BE PLANTED DURING THE FALLPLANTING SEASON: ACER RUBRUM PLATANUS X ACERIFOLIABETULA VARIETIES POPULUS VARIETIESCARPINUS VARIETIES PRUNUS VARIETIESCRATAEGUS VARIETIES PYRUS VARIETIESKOELREUTERIA QUERCUS VARIETIESLIQUIDAMBAR STYRACIFLUA TILIA TOMENTOSALIRIODENDRON TULIPIFERA ZELKOVA VARIETIES8.PLANTING PITS SHALL BE DUG WITH LEVEL BOTTOMS, WITH THE WIDTH TWICE THE DIAMETER OF ROOT BALL.THE ROOT BALL SHALL REST ON UNDISTURBED GRADE. EACH PLANT PIT SHALL BE BACKFILLED IN LAYERSWITH THE FOLLOWING PREPARED SOIL MIXED THOROUGHLY:8.1.1 PART PEAT MOSS8.2.1 PART COMPOSTED COW MANURE BY VOLUME8.3.3 PARTS TOPSOIL BY VOLUME8.4.21 GRAMS 'AGRIFORM' PLANTING TABLETS (OR APPROVED EQUAL) AS FOLLOWS:8.4.1.2 TABLETS PER 1 GALLON PLANT8.4.2.3 TABLETS PER 5 GALLON PLANT8.4.3.4 TABLETS PER 15 GALLON PLANT8.4.4.LARGER PLANTS: 2 TABLETS PER ½" CALIPER OF TRUNK9.FILL PREPARED SOIL AROUND BALL OF PLANT HALF-WAY AND INSERT PLANT TABLETS. COMPLETE BACKFILLAND WATER THOROUGHLY.10.ALL PLANTS SHALL BE PLANTED SO THAT THE TOP OF THE ROOT BALL, THE POINT AT WHICH THE ROOT FLAREBEGINS, IS SET AT GROUND LEVEL AND IN THE CENTER OF THE PIT. NO SOIL IS TO BE PLACED DIRECTLY ONTOP OF THE ROOT BALL.11.ALL PROPOSED TREES DIRECTLY ADJACENT TO WALKWAYS OR DRIVEWAYS SHALL BE PRUNED ANDMAINTAINED TO A MINIMUM BRANCHING HEIGHT OF 7' FROM GRADE.12.GROUND COVER AREAS SHALL RECEIVE A ¼" LAYER OF HUMUS RAKED INTO THE TOP 1" OF PREPARED SOILPRIOR TO PLANTING. ALL GROUND COVER AREAS SHALL BE WEEDED AND TREATED WITH A PRE-EMERGENTCHEMICAL AS PER MANUFACTURER'S RECOMMENDATION.13.NO PLANT, EXCEPT GROUND COVERS, GRASSES OR VINES, SHALL BE PLANTED LESS THAN TWO FEET (2') FROMEXISTING STRUCTURES AND SIDEWALKS.14.SUPPLY ALL PLANTS IN QUANTITIES SUFFICIENT TO COMPLETE THE WORK SHOWN ON THE DRAWINGS ANDLISTED IN THE PLANT LIST. IN THE EVENT OF A DISCREPANCY BETWEEN QUANTITIES SHOWN IN THE PLANT LISTAND THOSE REQUIRED BY THE DRAWINGS, THE LARGER NUMBER SHALL APPLY.15.ALL PLANTS SHALL BE APPROVED PRIOR TO INSTALLATION AND SHALL BE LOCATED ON SITE FOR THEAPPROVAL OF THE LANDSCAPE ARCHITECT. ANY INSTALLATIONS WHICH WERE NOT APPROVED BY THELANDSCAPE ARCHITECT AND WHICH ARE SUBSEQUENTLY REQUESTED TO BE MOVED WILL BE DONE AT NOADDITIONAL COST TO THE OWNER.16.PRECISE LOCATION OF ITEMS NOT DIMENSIONED ON THE PLAN ARE TO BE FIELD STAKED AND SHALL BESUBJECT TO THE REQUIREMENTS SPECIFIED IN THE PREVIOUS NOTE.17.ALL PLANTING BEDS AND TREE PITS SHALL BE MULCHED TO A DEPTH OF 3" WITH UN-DYED, AGED ANDSHREDDED BARK MULCH AS PER SPECIFICATIONS. NO MULCH IS TO TOUCH THE TRUNK OF THE TREE ORSHRUB.18.TREES SHALL NOT BE STAKED UNLESS OTHERWISE NOTED.19.BE RESPONSIBLE FOR ANY DAMAGED VEGETATION AND REPLACE OR REPAIR ANY DAMAGED MATERIAL.24.THE CONTRACTOR SHALL CONTACT “DIG-SAFE" AT 811 PRIOR TO CONSTRUCTION. BE RESPONSIBLE FORLOCATING ALL UTILITIES IN THE FIELD. WHERE PLANT MATERIAL MAY INTERFERE WITH UTILITIES, NOTIFY THELANDSCAPE ARCHITECT TO COORDINATE THEIR INSTALLATION. CONTRACTOR SHALL LOCATE AND VERIFY ALLEXISTING UTILITY LINES PRIOR TO PLANTING AND SHALL REPORT ANY CONFLICTS TO THE LANDSCAPEARCHITECT.25.ALL TREE PLANTING AREAS SHALL HAVE TOPSOIL 36" DEEP MINIMUM. ALL SHRUB AND GROUNDCOVERPLANTING AREAS SHALL HAVE CONTINUOUS BEDS OF TOPSOIL 12” DEEP MINIMUM. ALL SOD AND HYDROSEEDAREAS SHALL HAVE CONTINUOUS BEDS OF TOPSOIL 6" DEEP MINIMUM.26.FOR PLANTING SOIL MIX, SEE SPECIFICATIONS OR PLANTING DETAILS.27.ALL EXISTING RILL, GULLY OR CHANNEL EROSION SHALL BE FILLED WITH APPROPRIATE BACKFILL MATERIAL,FINE RAKED, SCARIFIED AND STABILIZED WITH APPROPRIATE VEGETATIVE MATERIAL AND / OR APPROPRIATESEDIMENTATION AND EROSION CONTROL MEASURES.28.ADJUSTMENTS IN THE LOCATION OF THE PROPOSED PLANT MATERIAL AS A RESULT OF EXISTING VEGETATIONTO REMAIN SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION.29.BE RESPONSIBLE FOR ALL MAINTENANCE REPAIR AND REPLACEMENT OF PLANT MATERIAL, AS REQUIRED, FORTHE DURATION OF THE PROJECT AND SUBSEQUENT WARRANTY PERIOD.30.PLANTINGS INSTALLED IN THE DRY SUMMER MONTHS AND / OR LAWN SEEDED OUT OF SPRING OR FALLPERIODS, IF ALLOWED BY OWNER, WILL REQUIRE AGGRESSIVE IRRIGATION PROGRAMS AT NO ADDITIONALCOST, UNLESS OTHERWISE DIRECTED BY THE OWNER.31.UPON COMPLETION OF PLANTING, REMOVE FROM SITE ALL EXCESS SOIL, MULCH, AND MATERIALS AND DEBRISRESULTING FROM WORK OPERATIONS. CLEAN UP SHOULD BE COMPLETED AT THE END OF EACH WORKINGDAY. RESTORE TO ORIGINAL CONDITIONS ALL DAMAGED PAVEMENTS, PLANTING AREAS, STRUCTURES ANDLAWN AREAS RESULTING FROM LANDSCAPING OPERATIONS.32.SURVEY, LOCATE, AND PROTECT ALL TREES WITHIN AREAS SHOWN AS "EXISTING VEGETATION TO REMAIN"WITHIN THE DEVELOPMENT ENVELOPE FOR REVIEW BY LANDSCAPE ARCHITECT PRIOR TO CLEARINGOPERATIONS.33.RESEED ALL DISTURBED AREAS.34.IF DISCREPANCIES EXIST BETWEEN THE NUMBER OF PLANTS DRAWN ON THE PLANTING PLAN AND THE NUMBEROF PLANTS IN THE PLANT LIST, THE PLANTING PLAN SHALL GOVERN.35.ALL NEW PLANTS SHALL BE BALLED & BURLAPPED OR CONTAINER GROWN, UNLESS OTHERWISE NOTED ON THEPLANT LIST.36.ANY PROPOSED SUBSTITUTIONS OF PLANT SPECIES SHALL BE MADE WITH PLANTS OF EQUIVALENT OVERALLFORM, HEIGHT, BRANCHING HABIT, FLOWER, LEAF, COLOR, FRUIT AND CULTURE, AND ONLY AFTER WRITTENAPPROVAL OF THE LANDSCAPE ARCHITECT.37.SCARIFY SUBGRADE AS SPECIFIED BEFORE PLACEMENT OF ANY PLANTING SOILS.38.DO NOT PLACE OR HANDLE SOILS THAT ARE WET.39.PROTECT ALL EXISTING SOILS AGAINST COMPACTION, CONTAMINATION WITH CONSTRUCTION MATERIALS, ANDALL DISTURBANCE.40.DO NOT PLACE ANY PLANTING SOIL PRIOR TO INSPECTION BY LANDSCAPE ARCHITECT.41.EXTENTS OF SAND BASED STRUCTURAL SOIL (SBSS) ARE APPROXIMATE. PROVIDE A MINIMUM OF 1,000 C.F. OFSBSS FOR EACH TREE.TRANSPLANTING1.ALL TRANSPLANTS SHALL BE DUG WITH INTACT ROOT BALLS CAPABLE OF SUSTAINING THE PLANT.2.IF PLANTS ARE TO BE STOCKPILED BEFORE REPLANTING, THEY SHALL BE HEALED IN WITH MULCH OR SOIL,ADEQUATELY WATERED AND PROTECTED FROM EXTREME HEAT, SUN AND WIND.3.PLANTS SHALL NOT BE DUG FOR TRANSPLANTING BETWEEN APRIL 10 AND JUNE 30.4.UPON REPLANTING, BACKFILL SOIL SHALL BE AMENDED WITH FERTILIZER AND ROOT GROWTH HORMONE.5.TRANSPLANTS SHALL BE GUARANTEED FOR THE LENGTH OF THE GUARANTEE PERIOD SPECIFIED HEREIN.6.IF TRANSPLANTS DIE, SHRUBS AND TREES LESS THAN SIX INCHES (6") DBH SHALL BE REPLACED IN KIND. TREESGREATER THAN SIX INCHES (6") DBH MAY BE REQUIRED TO BE REPLACED IN ACCORDANCE WITH THEMUNICIPALITY'S TREE REPLACEMENT GUIDELINES.IRRIGATION1.ALL VEGETATED AREAS AND LIVE LAWNS TO BE IRRIGATED.2.CONTRACTOR TO FURNISH AND INSTALL ALL ITEMS NECESSARY FOR A COMPLETE AND TURNKEY IRRIGATIONSYSTEM, INCLUDING, BUT NOT LIMITED TO, SPRAY HEADS, PUMPS, SUPPLY LINES, VALVES, VALVE BOXES, PUMPSTATIONS, METERS AND CONTROLLERS. MEET ALL LOCAL CODES.3.CONTRACTOR TO PROVIDE SHOP DRAWINGS SHOWING ALL COMPONENTS OF IRRIGATION SYSTEM PRIOR TOINSTALLATION. COORDINATE WITH OWNER ON INSTALLATION.4.COORDINATE FINAL LOCATION OF IRRIGATION, RAIN SENSOR AND VALVE BOXES WITH OWNER'S SITEREPRESENTATIVE.5.CONTRACTOR SHALL TEST DYNAMIC PRESSURE BEFORE STARTING WORK AND REPORT ANY DEVIATION TO THEOWNER'S REPRESENTATIVE BEFORE CONTINUING.6.GROUND IRRIGATION CONTROLLER TO EARTH IN ACCORDANCE WITH MANUFACTURER. COORDINATE WITH SITEELECTRICAL CONTRACTOR.7.COORDINATE LOCATION OF ALL EXISTING AND FUTURE UTILITIES ON SITE, CONTACT PROPER AUTHORITIES ANDUTILITY COMPANIES BEFORE THE START OF WORK.8.FLUSH ALL LATERAL LINES BEFORE INSTALLING IRRIGATION.9.SUBMIT PRODUCT CUT SHEETS AS PER THE WRITTEN SPECIFICATIONS TO THE ENGINEER FOR APPROVALPRIOR TO ORDERING MATERIAL AND BEGINNING WORK.10.MATERIAL SUBSTITUTIONS WHICH VARY FROM THE SPECIFIED PRODUCTS MUST BE SUBMITTED TO THEENGINEER FOR APPROVAL AS PART OF THE SUBMITTAL PROCESS.11.ONCE APPROVED SUBMITTALS HAVE BEEN RETURNED, WORK MAY BEGIN. OWNER'S REPRESENTATIVE MUST BENOTIFIED 7 DAYS IN ADVANCE OF THE START OF WORK TO COORDINATE ON-SITE SUPERVISION ANDADMINISTRATION.LIGHTING1.ELECTRICAL CONTRACTOR SHALL COORDINATE NEMA RATINGS OF ALL DEVICES PRIOR TO INSTALLATION.2.ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING AND CONFIRMING LOCATIONS ANDELECTRICAL DEVICES AND FIXTURES WITH OWNER.3.CONTRACTOR TO PROVIDE UPDATED TYPEWRITTEN PANEL SCHEDULES FOR PANELS WITHIN PROJECT SCOPEIN ACCORDANCE TO BUILDING STANDARDS.4.LOCATION OF ELECTRICAL PANELS/EQUIPMENT ARE APPROXIMATE. CONTRACTOR TO FIELD VERIFY ROUTINGAND DISTANCES PRIOR TO SUBMITTING PRICING.5.RUN BURIED CONDUIT AND CABLE IN AS DIRECT LINES AS POSSIBLE WITH MINIMUM NUMBER OF BENDS OFLONGEST POSSIBLE RADIUS IN AREAS OF EXISTING TREE PLANTING, CONDUIT OR CABLE SHALL NOT BEINSTALLED WITHIN 30 FEET OF TREE PLANTING, CONDUIT OR CABLE SHALL NOT BE INSTALLED WITHIN 20 FEETOR TREE, EXCEPT WHERE APPROACH TO FIXTURE REQUIRES OTHERWISE.6.COORDINATE FINAL LOCATION OF MANHOLES AND OR HANDHOLES IN THE FIELD WITH THE OWNER'S SITEREPRESENTATIVE PRIOR TO INSTALLATION.WATERING1.NEW PLANTINGS OR LAWN AREAS SHALL BE ADEQUATELY IRRIGATED BEGINNING IMMEDIATELY AFTERPLANTING. WATER SHALL BE APPLIED TO EACH TREE AND SHRUB IN SUCH MANNER AS NOT TO DISTURBBACKFILL AND TO THE EXTENT THAT ALL MATERIALS IN THE PLANTING HOLE ARE THOROUGHLY SATURATED.WATERING SHALL CONTINUE AT LEAST UNTIL PLANTS ARE ESTABLISHED.2.SITE OWNER SHALL PROVIDE WATER IF AVAILABLE ON SITE AT TIME OF PLANTING. IF WATER IS NOT AVAILABLEON SITE, CONTRACTOR SHALL SUPPLY ALL NECESSARY WATER. THE USE OF WATERING BAGS ISRECOMMENDED FOR ALL NEWLY PLANTED TREES.3.IF AN IRRIGATION SYSTEM HAS BEEN INSTALLED ON THE SITE, IT SHALL BE USED TO WATER PROPOSED PLANTMATERIAL, BUT ANY FAILURE OF THE SYSTEM DOES NOT ELIMINATE THE CONTRACTOR'S RESPONSIBILITY OFMAINTAINING THE DESIRED MOISTURE LEVEL FOR VIGOROUS, HEALTHY GROWTH.GUARANTEE1.THE LANDSCAPE CONTRACTOR SHALL GUARANTEE ALL PLANTS FOR A PERIOD OF 1 YEAR FROM APPROVAL OFLANDSCAPE INSTALLATION BY THE APPROVING AGENCY. CONTRACTOR SHALL SUPPLY THE OWNER WITH AMAINTENANCE BOND FOR TEN PERCENT (10%) OF THE VALUE OF THE LANDSCAPE INSTALLATION WHICH WILLBE RELEASED AT THE CONCLUSION OF THE GUARANTEE PERIOD AND WHEN A FINAL INSPECTION HAS BEENCOMPLETED AND APPROVED BY THE OWNER OR AUTHORIZED REPRESENTATIVE.2.ANY DEAD OR DYING PLANT MATERIAL SHALL BE REPLACED FOR THE LENGTH OF THE GUARANTEE PERIOD.REPLACEMENT OF PLANT MATERIAL SHALL BE CONDUCTED AT THE FIRST SUCCEEDING PLANTING SEASON.ANY DEBRIS SHALL BE DISPOSED OF OFF-SITE, WITHOUT EXCEPTION.3.TREES AND SHRUBS SHALL BE MAINTAINED BY THE CONTRACTOR DURING CONSTRUCTION AND THROUGHOUTTHE 90 DAY MAINTENANCE PERIOD AS SPECIFIED HEREIN. CULTIVATION, WEEDING, WATERING AND THEPREVENTATIVE TREATMENTS SHALL BE PERFORMED AS NECESSARY TO KEEP PLANT MATERIAL IN GOODCONDITION AND FREE OF INSECTS AND DISEASE.4.LAWNS SHALL BE MAINTAINED THROUGH WATERING, FERTILIZING, WEEDING, MOWING, TRIMMING AND OTHEROPERATIONS SUCH AS ROLLING, REGARDING AND REPLANTING AS REQUIRED TO ESTABLISH A SMOOTH,ACCEPTABLE LAWN, FREE OF ERODED OR BARE AREAS.CLEANUP1.UPON THE COMPLETION OF ALL LANDSCAPE INSTALLATION AND BEFORE THE FINAL ACCEPTANCE, THECONTRACTOR SHALL REMOVE ALL UNUSED MATERIALS, EQUIPMENT AND DEBRIS FROM THE SITE. ALL PAVEDAREAS ARE TO BE CLEANED.2.THE SITE SHALL BE CLEANED AND LEFT IN A NEAT AND ACCEPTABLE CONDITION AS APPROVED BY THE OWNEROR AUTHORIZED REPRESENTATIVE.MAINTENANCE1.A 90 DAY MAINTENANCE PERIOD SHALL COMMENCE AT THE END OF ALL LANDSCAPE INSTALLATIONOPERATIONS. THE 90 DAY MAINTENANCE PERIOD ENSURES TO THE OWNER/OPERATOR THAT THE NEWLYINSTALLED LANDSCAPING HAS BEEN MAINTAINED AS SPECIFIED ON THE APPROVED LANDSCAPE PLAN. ONCETHE INITIAL 90 DAY MAINTENANCE PERIOD HAS EXPIRED, THE OWNER/OPERATOR MAY REQUEST THAT BIDDERSSUBMIT AN ALTERNATE MAINTENANCE BID FOR A MONTHLY MAINTENANCE CONTRACT. THE ALTERNATEMAINTENANCE CONTRACT WILL ENCOMPASS ANY WORK THAT IS CONSIDERED APPROPRIATE TO ENSURE THATPLANT AND LAWN AREAS ARE HEALTHY AND MANICURED TO THE APPROVAL OF THE OWNER/OPERATOR.OWNERS MAINTENANCE RESPONSIBILITIES1.UPON OWNER'S (OR OWNER CONTRACTOR'S) COMPLETION OF LANDSCAPING WORK, THE OWNER IS FULLYRESPONSIBLE FOR ALL FUTURE MAINTENANCE, CARE, UPKEEP, WATERING, AND TRIMMING OF ALL INSTALLEDVEGETATION, PLANTS, TREE, BUSHES, SHRUBS, GRASSES, GRASS, ORNAMENTAL PLANTS AND FLOWERS,FLOWERS, GROUND COVER, AND LANDSCAPING, INCLUDING ALL LANDSCAPE ISLANDS AND AREAS ADJACENTOR PART OF THE LANDSCAPED AREAS. THIS RESPONSIBILITY INCLUDES, BUT IS NOT LIMITED TO, THEFOLLOWING:1.1.TREES ADJACENT TO WALKWAYS AND AREAS OF PEDESTRIAN TRAFFIC MUST BE MAINTAINED TO ASSURETHAT ANY BRANCHES MUST BE LIMBED UP TO A CLEARANCE HEIGHT OF 7 FT. (FROM ALL PEDESTRIANSURFACES) OR PRUNED BACK TO AVOID ANY INTERFERENCE WITH THE TYPICAL PATH OF TRAVEL.1.2.TREES WITHIN VEHICULAR SIGHT LINES, AS ILLUSTRATED ON THE LANDSCAPE PLAN, ARE TO BE TRIMMEDTO A CLEARANCE HEIGHT OF 7 FT. (FROM ALL PAVED, TRAVELED SURFACES), OR AS OTHERWISE INDICATEDON THE PLANS.1.3.VEGETATIVE GROUND COVER, SHRUBS AND ORNAMENTAL PLANTS AND GRASSES MUST BE TRIMMED SOTHAT NO PORTION OF THE PLANT EXCEEDS 30 INCHES ABOVE GRADE (OF ALL PAVED, TRAVEL SURFACES)ALONG AND WITHIN THE SIGHT LINES OF PARKING LOTS AND INGRESS-EGRESS WAYS.1.4.FALLEN PLANT FLOWERS, FRUIT, SEEDS AND DEBRIS DROPPINGS ARE TO BE REMOVED IMMEDIATELY FROMVEHICULAR AND PEDESTRIAN TRAFFIC AREAS TO PREVENT TRIPPING, SLIPPING OR ANY OTHER HAZARDS.2.THESE REQUIREMENTS DO NOT AFFECT THE PLANT LIFE GUARANTEES THE LANDSCAPE CONTRACTOR ISREQUIRED TO PROVIDE.LANDSCAPE NOTES TO BE READ INCONJUNCTION WITH PLANS, DETAILSAND SPECIFICATIONSL-600LANDSCAPEGENERALNOTES6 REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY1234567REVISION 7 -01/19/2024CLIENT COMMENTSDTMM02/02/2024CITY COMMENTSDTMM03/04/2024CITY COMMENTSDTMM03/20/2024CITY COMMENTSDT/JKMM04/15/2024CITY AND TDECOMMENTSDTMM05/03/2024ISSUED FORCONSTRUCTIONDTJE/MB06/14/2024ADDENDUM 1DTJE06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORC:\PROGRAMDATA\_BOHLER\C3D2024\TEMP\ACPUBLISH_11952\NYB230191.00-LSCP-0A----->LAYOUT: L-601 DETAILSDT THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191DT/JKJE/MB11/30/2023NYB230191.00-LSCP-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comM A T THEW J. MRVA002359R E GISTE R E D LANDSCAPE ARCHITECTSTATE OF NEW YOR K EXCELSI OREXP: 06/30/2024SYNTHETIC TURF MATTING TO BEFASTENED TO NAILER PLATE PERMANUFACTURER SPECIFICATIONS2" x 4" SYNTHETIC NAILER PLATE18" STAKE FASTENED TO NAILER PLATESYNTHETIC TURF MATTING3-4" OF 38" - 12" CLEAN ANGULAR STONECOMPACTED SUB-GRADE6" X 12" FLUSH CAST INPLACE CONCRETE CURBNOTES:1.CONTRACTOR TO PROVIDE SHOP DRAWINGS AND SAMPLES ON TURF AREA FORAPPROVAL BY OWNERS REPRESENTATIVE.2.CONTRACTOR TO BUILD A 5'X5' MOCK PANEL ON SITE PRIOR TO CONSTRUCTION.3.CONTRACTOR TO HAVE THE BASE APPROVED PRIOR TO LAYING TURFSYNTHETIC TURFNOT TO SCALE(S700.03xx_07/2022)3BOCCE LAYOUT PLANNOT TO SCALE(S700.03xx_07/2022)8NOTES:1.THIS DETAIL IS FOR BID ANDBUDGETARY PURPOSES ONLY.CONTRACTOR SHALL BE RESPONSIBLEFOR HAVING A FOUNDATION DESIGNPREPARED BY A QUALIFIEDSTRUCTURAL ENGINEER CONSIDERINGLIGHTING MANUFACTURERREQUIREMENTS, LOCAL WIND LOADSAND SITE SPECIFIC SOIL PARAMETERS.2.SOME SITE CONDITIONS AND/ORLOCATIONS MAY REQUIRE VIBRATIONDAMPENING MEASURES ASDETERMINED BY A STRUCTURALENGINEER.3.THE STRUCTURAL ENGINEER SHALL BENOTIFIED OF THE INTENT TO MOUNTANYTHING TO THE POLE, ASIDE FROMTHE LIGHT FIXTURES, INCLUDING BUTNOT LIMITED TO CAMERAS, BANNERS,FLAGS, SIGNAGE, ETC. AS IT WILLIMPACT THE POLE AND FOUNDATIONDESIGN.4.CONCRETE FOOTING SHALL BE BURIEDA MINIMUM OF 4" BELOW GRADE.FOOTING SHALL NOT BE VISIBLE ABOVEGRADE.5.SUBMIT FOUNDATION SHOP DRAWINGSTO ENGINEER.6.ANCHOR BOLTS FURNISHED WITH POLE24" DIA2'COPPER GROUND WIRE TO GROUND LUGUNDISTURBED EARTHBEND ANCHOR BOLTSRIGID GALVANIZED CONDUIT#3 HORIZ. REBARTACKWELD NUTS AFTER LEVELINGANCHOR BOLTS SEE NOTE #2 BELOW#5 VERTICAL REBAR (TYP. OF 6)REINFORCED CONCRETE BASE(3000 PSI @ 28 DAYS)HAND RUBBED CONCRETE3/4" x 10'-0" GROUND RODCHAMFER45°(TYP.)BASE PLATELEVELING NUTS &BASE COVERWASHERS BELOWBASE PLATEFINISHED GRADE ATWITH EXOTHERMIC CONNECTIONBETWEEN GROUND WIREAND GROUND RODHAND HOLECONDUIT AND WIRING TO OTHERFIXTURES AND/OR PANEL#6 BARE COPPER GROUND WIRE4" MIN.CENTER OF FOUNDATION@ 10"o.c. E.W.LIGHT POLE AND BASE DETAILNOT TO SCALE(S700.03xx_07/2022)6STAMPED CONCRETE PATTERN TO BEFRACTURED THIN SLATE PATTERN IN STONEGRAY OR APPROVED EQUAL. OWNER TOSELECT FINAL PATTERN AND COLOR PRIORTO INSTALL.4" DENSE GRADED CRUSHEDSTONE BASE COURSE4" GRAVEL BORROWSUB-BASE COURSE6" x 6" 1.4X1.4 WELDED WIREMESH, 2" MIN. COVERSTAMPED CONCRETE PAVEMENTNOT TO SCALE(S700.03xx_07/2022)1TRASH RECEPTACLE REFER TOSPECIFICATIONS FOR MODEL4" CONC. PAVING (SEEDETAIL)8" DEPTH GRAVEL BASECOMPACTEDSUBGRADEEMBEDDED MOUNT, INSTALLPER MANUFACTURERRECOMMENDATIONSBIKE RACKREFER TO SPECIFICATIONSFOR MODEL.4" CONC. PAVING(SEE DETAIL)8" DEPTHGRAVEL BASECOMPACTEDSUBGRADEMOVEABLE TRASH RECEPTACLENOT TO SCALE(S700.03xx_07/2022)BIKE RACKSNOT TO SCALE(S700.03xx_07/2022)TIMBER PLATFORM WITH SWINGNOT TO SCALE(S700.03xx_07/2022)LOCAL CODE LAYOUT REQUIREMENTS574LOUNGE SWING ANDU-FRAME INSTALLED TOMANUFACTURER'SSPECIFICATIONSSWING FOOTING TO BEDESIGNED BY LICENSEDSTRUCTURAL ENGINEERMOVEABLE PLANTERNOT TO SCALE(S700.03xx_07/2022)2PLANT APPROX. 2" BELOWTOP OF PLANTERINSTALL IRRIGATION RESERVOIRSYSTEM OR SIMILAR APPROVEDBY LANDSCAPE ARCHITECTLIGHT WEIGHTPLANTING MEDIA3'5'2X2" THERMALLY MODIFIED ASH DECKINGFIXED TO JOIST WITH COUNTERSUNK HDGDECKING SCREWS AND PLUGSDECK FOOTING TO BEDESIGNED BY LICENSEDSTRUCTURAL ENGINEER2X4" PRESSURE TREATED JOISTFIXED TO POST WITH HDG BOLTS4X4" PRESSURE TREATED POST EMBEDDEDIN 1' DIA. 4' LONG CONCRETE FOOTING6" GRAVEL SUBGRADENOTES:1. SHOP DRAWINGS TO BE PROVIDED TO LANDSCAPEARCHITECT FOR REVIEW PRIOR TO CONSTRUCTION.11'60'6" TIMBER CURBNOTES:1.SECURE TIMBER CURB WITH LANDSCAPE SCREWS LAP CORNER JOINTS2.SHOP DRAWINGS TO BE PROVIDED TO LANDSCAPE ARCHITECT FOR REVIEW PRIOR TO CONSTRUCTION.3.REDWOOD CAP SHALL BE STAINED AND SEALED COLOR TO MATCH WALNUT STAIN PROVIDED BY ARCHITECT.WEEP HOLES 6' O.C.PERIMETER DRAINSCORE BOARD - REFER TOARCHITECTURAL DRAWINGSSYNTHETIC TURFOYSTER BASE BOCCEBLEND STONE INFILLDECKINGJOISTSPOSTS8'8'FRAMING PLANDECKING TO WRAP AROUNDFRONT AND BACK OF PLATFORMFRAME INSET 2" ON SIDES12" MAX.DECKINGJOISTSPOSTSL-601LANDSCAPEAMENITYDETAILS4' MIN.12"LIGHT POST WITH SPEAKERS - REFERTO ARCHITECTURAL DRAWINGS5' ADA ACCESS WITH FLUSHCURB AND HINGED TIMBERSIDE RAIL5' ADA ACCESS WITH FLUSHCURB AND HINGED TIMBERSIDE RAILCOMPACTEDSUBGRADE6'-6" MIN.NOTES:1.PROVIDE (2) IRRIGATION RESERVOIRS PER5'X10' PLANTER AS SHOWN IN LAYOUT:11'1'6 REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY1234567REVISION 7 -01/19/2024CLIENT COMMENTSDTMM02/02/2024CITY COMMENTSDTMM03/04/2024CITY COMMENTSDTMM03/20/2024CITY COMMENTSDT/JKMM04/15/2024CITY AND TDECOMMENTSDTMM05/03/2024ISSUED FORCONSTRUCTIONDTJE/MB06/14/2024ADDENDUM 1DTJE06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORC:\PROGRAMDATA\_BOHLER\C3D2024\TEMP\ACPUBLISH_11952\NYB230191.00-LSCP-0A----->LAYOUT: L-602 DETAILSDT THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191DT/JKJE/MB11/30/2023NYB230191.00-LSCP-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comM A T THEW J. MRVA002359R E GISTE R E D LANDSCAPE ARCHITECTSTATE OF NEW YOR K EXCELSI OREXP: 06/30/2024MIN. 4' DEPTH CONDUIT- SEE ELECTRICAL PLANSFINISH GRADE. SEE PLANFOR MATERIALS(4) 5/8" x 14"L x 2"GALVANIZED STEEL ANCHOR BOLTSTHIS SURFACE MUST BEFLUSH TO FINISHED GRADEANCHOR BOLTS, HOT-DIP GALVANIZEDSET TO SUIT POST BASE (79817)4000 PSI CONCRETESPREAD FOOTINGAACONDUIT ENTRY(3) 5/16" DIA. x 10" LONGANCHOR BOLTSNOTE: 1.CORNERS OF BASE & LUMINAIRE MUST BE ALIGNED INDESIRED LOCATION & ORIENTATION (ANCHORAGEREMOVAL MAY BE REQUIRED IF NOT PROPERLY ALIGNED)2.REFER TO ARCHITECT SPECIFICATIONS FOR PRODUCTINFORMATIONPLAN VIEWSECTION VIEW A-A1" GROUT1 OF 2 RE-BARS(1 EACH FACE)BOLLARD LIGHT INSTALLED TOMANUFACTURER'S SPECIFICATIONSBOLTS PER LIGHT MFR7 58"WIDTH OF BOLLARD3"LIGHT BOLLARDNOT TO SCALE(S700.03xx_07/2022)10SECURE BENCH WITH NUT ONTOP OF SURFACE MOUNT TABSURFACE MOUNT TAB WITH Ø716" [11]HOLES FOR ANCHORING. NON-CORROSIVEMOUNTING HARDWARE SUPPLIED BY OTHERSBENCH INSTALLED TOMANUFACTURER'SSPECIFICATIONS12" Ø x 6" TAMPERPROOF EXPANSIONBOLTS WITHSLEEVES ANDWASHERS4" CONC. PAVING (SEE DETAIL)PROVIDE SETTING NUT ON LAG BOLTLEVEL WITH PROP. GRADE8" DEPTH GRAVEL BASECOMPACTEDSUBGRADETIMBER BENCHNOT TO SCALE(S700.03xx_07/2022)TIMBER PLATFORMNOT TO SCALE(S700.03xx_07/2022)129ANCHOR PLATFORM TO CONCRETE PADPER MANUFACTURER'S SPECIFICATIONS6" DEPTH CONCRETEPAD ON 6" GRAVELSECURE BENCH WITH NUT ONTOP OF SURFACE MOUNT TABSURFACE MOUNT TAB WITH Ø716" [11] HOLESFOR ANCHORING. NON-CORROSIVEMOUNTING HARDWARE SUPPLIED BYOTHERSBENCH INSTALLED TOMANUFACTURER'SSPECIFICATIONS12" Ø x 6" TAMPERPROOF EXPANSIONBOLTS WITHSLEEVES ANDWASHERS4" CONC. PAVING(SEE DETAIL)PROVIDE SETTING NUTON LAG BOLT LEVELWITH PROP. GRADE8" DEPTH GRAVEL BASECOMPACTEDSUBGRADEPICNIC TABLENOT TO SCALE(S700.03xx_07/2022)11TABLE INSTALLED TOMANUFACTURER'SSPECIFICATIONS(2) 6X6" PT TIMBER CURB1" PVC WEEP HOLE 6' O.C.1" OYSTER BASE BOCCE BLEND STONE INFILL1" LEVELING COURSE OF38" DENSE GRADED CRUSHED STONEFILTER FABRIC BARRIER4" COMPACTED 12" CRUSHED STONE6" GRAVEL SETTING BEDCOMPACTED SUB GRADE24" METAL REBAR THRU BOTH TIMBERSBOCCE DETAILNOT TO SCALE(S700.03xx_07/2022)13STRING LIGHT ATTACHMENTNOT TO SCALE(S700.03xx_07/2022)143035T 190 HDG U-BOLT WELDED TO 6"X6" HDGPLATE AND FIXED TO STRUCTURAL BEAMSTRING LIGHT STRUCTURAL CABLE ANDALL REQUIRED FIXINGS TO BE DESIGNEDBY LICENSED STRUCTURAL ENGINEERNOTES:1. SHOP DRAWINGS TO BE PROVIDED TO LANDSCAPEARCHITECT FOR REVIEW PRIOR TO CONSTRUCTION.3" COMPACTEDSTONE DUSTSTEEL LANDSCAPE EDGINGPROCESSED GRAVELUNDISTURBED ORCOMPACTED SUBGRADEMATERIAL VARIESREFER TO PLANSPROVIDE LAYER OFLANDSCAPE FABRICBETWEEN STONE DUSTAND STONE PACKWIDTH VARIESSEE PLANSSTABILIZED STONE DUSTNOT TO SCALE(S700.03xx_07/2022)158'8'1.5'L-602LANDSCAPEAMENITYDETAILS2"X6" TIMBER SIDE RAILS3"2"PLAN VIEW4"6'-0"ELEVATIONNOTES:1.FENCE TO HAVE NATURAL FINISH.2.USE 2" GALVANIZED NAILS FOR 1"X6" SLATS3.USE 4" GALVANIZED NAILS FOR 2"X4" FRAMING4.ALL WOOD TO BE PREMIUM GRADE TIMBER5.SHOP DRAWINGS TO BE SUBMITTED TO LANDSCAPEARCHITECT FOR APPROVAL PRIOR TO CONSTRUCTION1/2" OVERLAP2"x4" BOTTOM RAIL2"x4" INTERMEDIATE RAIL2"x4" TOP RAIL2"x4" RAIL1"x6" SLATS ONALTERNATE SIDES(WITH 1/2" OVERLAP4"x4"x10' POST4"x4"x10' POST1"x6" SLATS ONALTERNATE SIDESGROUND LEVELCOMPACTED 3/4" GRAVELEXISTING SUBGRADEBOARD ON BOARD BOUNDARY FENCENOT TO SCALE(S700.03xx_07/2022)16SYNTHETIC TURF, SEE PLANS FOR EXTENTS6 REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY1234567REVISION 7 -01/19/2024CLIENT COMMENTSDTMM02/02/2024CITY COMMENTSDTMM03/04/2024CITY COMMENTSDTMM03/20/2024CITY COMMENTSDT/JKMM04/15/2024CITY AND TDECOMMENTSDTMM05/03/2024ISSUED FORCONSTRUCTIONDTJE/MB06/14/2024ADDENDUM 1DTJE06/14/2024DISCLAIMER PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORC:\PROGRAMDATA\_BOHLER\C3D2024\TEMP\ACPUBLISH_11952\NYB230191.00-LSCP-0A----->LAYOUT: L-603 DETAILSDT THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NYB230191DT/JKJE/MB11/30/2023NYB230191.00-LSCP-0APROPOSED SITEPLAN DOCUMENTSTHBC NY, LLCPROPOSEDDEVELOPMENTSEC. 178.00 - BLK - PARCEL 15SOUTH BROADWAYCITY OF SARATOGA SPRINGSSARATOGA COUNTY, NEW YORKISSUED FORCONSTRUCTIONALWAYS CALL 811It's fast. It's free. It's the law.TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER17 COMPUTER DRIVE WESTALBANY, NY 12205Phone:(518) 438-9900Fax: (518) 438-0900www.BohlerEngineering.comM A T THEW J. MRVA002359R E GISTE R E D LANDSCAPE ARCHITECTSTATE OF NEW YOR K EXCELSI OREXP: 06/30/2024TREE PLANTING DETAILNOT TO SCALE(S700.03xx_07/2022)PLANTED BERMNOT TO SCALE(S700.03xx_07/2022)1.PRIOR TO SEEDING, AREA IS TO BE TOPSOILED, FINE GRADED, AND RAKED OF ALLDEBRIS LARGER THAN 2" DIAMETER.2.PRIOR TO SEEDING, CONSULT MANUFACTURER'S RECOMMENDATIONS ANDINSTRUCTIONS.3.SEEDING RATES:·PERENNIAL RYEGRASS 1/2 LB/1000 SQ FT·KENTUCKY BLUEGRASS 1 LB/1000 SQ FT·RED FESCUE 1/2 LB/1000 SQ FT·SPREADING FESCUE 1/2 LB/1000 SQ FT·FERTILIZER (16.32.16) 2 LB/1000 SQ FT·LIQUID LIME 1 GAL/800 GAL.·TANK TACKIFIER 35 LB/800 GAL.·TANK FIBER MULCH 30 LB/1000 SQ FT4.GERMINATION RATES WILL VARY AS TO TIME OF YEAR FOR SOWING. CONTRACTOR TOIRRIGATE SEEDED AREA UNTIL AN ACCEPTABLE STAND OF COVER IS ESTABLISHED BYOWNER.2NOTES:1.NO SOIL OR MULCH SHALL BE PLACED AGAINST ROOT COLLAR OF PLANT.2.REMOVE ALL NON-BIODEGRADABLE MATERIAL AND ROPE FROM TRUNK & TOP OF ROOT BALL. FOLDBURLAP BACK 1/3 FROM ROOT BALL.3.PLANTING DEPTH SHALL BE THE SAME AS GROWN IN NURSERY.4.THOROUGHLY SOAK THE TREE ROOT BALL AND ADJACENT PREPARED SOIL SEVERAL TIMES DURINGTHE FIRST MONTH5.AFTER PLANTING AND REGULARLY THROUGHOUT THE FOLLOWING TWO SUMMERS.6.THE BOTTOM OF PLANTING PIT EXCAVATIONS SHOULD BE ROUGH TO AVOID MATTING OF SOILLAYERS AS7.NEW SOIL IS ADDED. IT IS PREFERABLE TO TILL THE FIRST LIFT (2 TO 3 IN.) OF PLANTING SOIL INTOTHE SUBSOIL.8.REFER TO THE CHART "GENERAL RANGE OF SOIL MODIFICATIONS & VOLUMES FOR VARIOUS SOILCONDITIONS" TO DETERMINE MINIMUM WIDTH OF PREPARED SOIL.9.SUBSTITUTE ARBORVITAE STAKING SYSTEM WHEN SPECIFIED.REINFORCED RUBBER HOSE (1/2" DIA. BLACK)12 GAUGE GALVANIZED WIRE GUYS TWISTEDFOLD BURLAP AWAY FROM TOP OF ROOTBALLTWICE THE WIDTH OF ROOTBALL FORPREPARED SOIL FOR TREES.PREPARED SOIL FOR TREES1 PART PEAT MOSS1 PART COW MANURE3 PARTS TOPSOIL(RECOMMENDATION ONLY. SEE SOIL MOD. CHART)UNDISTURBED SUBGRADEDIG WIDE, SHALLOW HOLE WITHTAMPED SIDESTAMP SOIL SOLIDLY AROUND BASEOF ROOT BALLAVOID PURCHASING TREES WITH TWO LEADERSOR REMOVE ONE AT PLANTING: OTHERWISE, DONOT PRUNE TREE AT PLANTING EXCEPT FORSPECIFIC STRUCTURAL CORRECTIONS.SET ROOT BALL FLUSH TO GRADE OR SEVERALINCHES HIGHER IN POORLY DRAINING SOILS.4" BUILT-UP EARTH SAUCER3" DOUBLE SHREDDED HARDWOOD BARKMULCH (UNLESS OTHERWISE SPECIFIED) (DONOT PLACE MULCH IN CONTACT WITH TREETRUNK)LANDSCAPE FABRIC AS SPECIFIED.ALL PLANTING CONTAINERS, BASKETS ANDNON-BIODEGRADABLE MATERIALS SHALLBE REMOVED FROM ROOT BALLS.SET ROOT BALL ON UNDISTURBEDSOIL IN BOTTOM OF HOLE2" DIA. HARDWOOD STAKES 2/3 TREE HT.3 PER TREEELEVATIONWOOD & WIRE SNOW FENCE USED ASTREE GUARD TO PREVENT DAMAGE FROMCONSTRUCTION EQUIPMENT.TREE DRIP LINE/TREE PROTECTION ZONEAREA WITHIN TREE PROTECTION ZONE TOREMAIN UNDISTURBED DURINGCONSTRUCTION.6' WOOD OR STEEL FENCE POSTS AT 8'MAXIMUM CENTER TO CENTER (MINIMUM 2'BELOW GRADE).4' HIGH WOOD & WIRE SNOW FENCEW/WOOD STAKES AT A MAXIMUM OF 8'ON CENTER. AS AN OPTION,ORANGE/FLUORESCENT HIGH-DENSITY"VISI-FENCE" OR APPROVED EQUAL CANBE USED.TREE PROTECTION FENCE SHALL BEINSTALLED TO FOLLOW TREE CANOPYDRIP LINE OR PROPOSED LIMITS OFDISTURBANCE.AREA OF SITECONSTRUCTIONPLAN8" - 12"24" MINIMUMFOR CONTAINER-GROWN SHRUBS, PLANT SHALL BETRANSPLANTED AT THE SAME GRADE AS IN THECONTAINER. REMOVE THE CONTAINER, USEFINGER OR SMALL HAND TOOLS TO PULL THEROOTS OUT OF THE OUTER LAYER OF POTTINGSOIL; THEN CUT OR PULL APART ANY ROOTS THATCIRCLE THE PERIMETER OF THE CONTAINER.3" DOUBLE-SHREDDED HARDWOOD BARK MULCH(DO NOT PUT MULCH AGAINST THE BASE OF THEPLANT).LANDSCAPE FABRIC AS SPECIFIEDFINISHED GRADEPLACE SHRUB ON FIRM SOIL IN BOTTOM OF HOLE.UNDISTURBED SUBGRADEWHEN APPROPRIATE, PLANT MULTIPLESHRUBS IN CONTINUOUS PLANTING HOLE.SOIL SURFACE ROUGHENEDTO BIND WITH NEW SOIL.BEFORE PLANTING, ADD 3" TO 4" OFWELL-COMPOSTED LEAVES ANDRECYCLED YARD WASTE TO BED ANDTILL INTO TOP 6" OF PREPARED SOIL.PLANTING MIX:1 PART PEAT MOSS1 PART COW MANURE3 PARTS TOPSOIL(SEE SOIL MODIFICATION CHART)PLANT SHALL BE PLANTED SO THATTHE POINT AT WHICH THE ROOT FLAREBEGINS IS SET LEVEL WITH GRADE.CUT AND REMOVE BURLAP FROM TOPONE-THIRD OF ROOT BALL AS SHOWN.CONTAINERB&BPREPARED SOIL FOR TREES(SEE PLANTING DETAIL)UNDISTURBED SUBGRADESEE DECIDUOUS OR EVERGREENTREE DETAIL FOR PLANTINGPURPOSESTREEBIOBARRIER ROOTBARRIER FABRIC ORAPPROVED EQUALBIOBARRIER ROOT BARRIERFABRIC TO BE INSTALLEDTO THE DEPTH OF THEBOTTOM OF STONE BASECOURSE OR 10",WHICHEVER IS GREATERNOTES:1. ANY TREE INSTALLED WITHIN 10 FT. OF NEW CONCRETESIDEWALKS SHOULD BE INSTALLED WITH BIOBARRIER ROOTBARRIER FABRIC AS SHOWN2. TREES SHALL BE INSTALLED ACCORDING TO THEAPPROPRIATE PLANTING DETAIL.10' MAX.CONC. SIDEWALKINCORPORATE 2" OF PEATINTO 6" OF PLANTINGMIXTURE, AS SPECIFIED1" DOUBLE SHREDDEDHARDWOOD BARK MULCHEDGING(AS SPECIFIED)FINISHED GRADETOPSOILFINISHGRADE18" STAKE INTO UNDISTURBEDGROUND EVERY 30" O.C. LAPJOINTS AS PER MANUFACTURERSRECOMMENDATION.3/16" x 4" BLACKALUMINUM EDGINGLAWN OR GRAVEL AREAUNDISTURBED SUBGRADEPREPAREDTOPSOILMULCHAS SPECIFIEDARBORTIEARBORTIEARBORTIEABARBORTIEARBORTIESTEP 1:TIE A SIMPLE KNOT 18-24"FROM EITHER END OF THEARBORTIE.(DEPENDING ON THEDIAMETER OF THE TREE)THIS END WRAPPEDAROUND TREE AFTERKNOT IS TIGHTENEDTYPICALGUYINGINSTALLATIONTHIS ENDTO STAKETHIS ENDTO STAKESTEP 4:SLIDE KNOT JUST COMPLETEDUP TO THE KNOT TIED IN STEP 1.FASTEN FREE END TO STAKE ORANCHOR.THIS ENDTO STAKESTEP 3:FOLLOW MOTION OF ARBORTIEAS SHOWN, FINISHING THE KNOTBY PULLING TIGHTLY ON POINTSA AND B AT THE SAME TIME.STEP 2:WRAP THIS END AROUNDTREE. BEGIN A NEW KNOTBELOW THE KNOT THATWAS TIED IN STEP 1.THIS ENDTO STAKETHIS ENDTO STAKESTEP 5:THE ARBORKNOT PROVIDESSECURE, GIRDLE FREEATTACHMENT OF THEARBORTIE TO TREE.13TREE TRUNKMIN. OF THREE (3)STAKES TO EACHTREENOTES:SPECIFIED ARBORTIE GREEN (OR WHITE)STAKING AND GUYING MATERIAL IS TO BEFLAT WOVEN POLYPROPYLENE MATERIAL.34" WIDE, 900 LB. BREAK STRENGTH.ARBORTIE SHALL BE FASTENED TOSTAKES IN A MANNER WHICH PERMITSTREE MOVEMENT AND SUPPORTS THETREE.2MOUND TOP OF BERMADJACENT PAVEMENT -SEE PLANS1'WIDTH VARIES - SEE PLAN1'1'1:3 MAX. SLOPETREE PROTECTION DURING SITE CONSTRUCTIONNOT TO SCALE(S700.03xx_07/2022)SHRUB PLANTING DETAILNOT TO SCALE(S700.03xx_07/2022)BIOBARRIER ROOT BARRIER DETAILNOT TO SCALE(S700.03xx_07/2022)GROUNDCOVER PLANTINGNOT TO SCALE(S700.03xx_07/2022)BASIN SEED MIX SPECIFICATIONSNOT TO SCALE(S700.03xx_07/2022)HYDROSEED GRASS SPECIFICATIONSNOT TO SCALE(S700.03xx_07/2022)BLACK ALUMINUM EDGINGNOT TO SCALE(S700.03xx_07/2022)ARBORTIE STAKING DETAILNOT TO SCALE(S700.03xx_07/2022)FINISHED GRADE. MATERIAL VARIES: SEE PLANSCRUSHED STONE,SEE SPECIFICATIONSFINISHED GRADE. SEE PLANSFOR ELEVATIONWEED BARRIER FABRIC4"1/8" x 4" STEEL EDGE WITH STAKES EVERY 2'STONE MAINTENANCE STRIPNOT TO SCALE(S700.03xx_07/2022)VARIES - SEEGRADING PLAN VARIES - SEE PLANADJACENT PAVING- SEE PLANBASIN SEEDMIX, TYP.SWALE PLANTINGNOT TO SCALE(S700.03xx_07/2022)SEEDEDLAWN, TYP.TREE PLANTING,TYP.2"1.5' MIN.2"3' MIN. AT TREES MULCH PERSPECIFICATIONSTOPSOIL PERSPECIFICATIONSTOPSOIL PERSPECIFICATIONS3' MIN. AT TREES 1.5' MIN.381112910764521"NEW ENGLAND SHOWY WILDFLOWER SEED MIX" AS PREPARED BY:NEW ENGLAND WETLAND PLANTS, INC820 WEST STREET, AMHERST, MA 01002PHONE:413-548-8000EMAIL:INFO@NEWP.COMWEBSITE: WWW.NEWP.COMAPPLICATION RATE: 23 lbs/acre | 1900 sq ft/lbSPECIES Little Bluestem (Schizachyrium scoparium), Red Fescue (Festuca rubra), Indian Grass (Sorghastrumnutans), Partridge Pea (Chamaecrista fasciculata), Canada Wild Rye (Elymus canadensis), Riverbank Wild Rye(Elymus riparius), Butterfly Milkweed (Asclepias tuberosa), Black Eyed Susan (Rudbeckia hirta), Lance LeavedCoreopsis (Coreopsis lanceolata), Ox Eye Sunflower (Heliopsis helianthoides), Common Sneezeweed (Heleniumautumnale), Marsh Blazing Star (Liatris spicata), Blue Vervain (Verbena hastata), New England Aster (Asternovae-angliae), Wild Blue False Indigo (Baptisia australis), HollowStem Joe Pye Weed (Eupatorium fistulosum/Eutrochium fistulosum), Early Goldenrod (Solidago juncea).NATIVE WILDFLOWER SEED MIX SPECIFICATIONNOT TO SCALE(S700.03xx_07/2022)13L-603LANDSCAPEPLANTINGDETAILS1' LEVEL AT BASE1' LEVEL AT BASEEXISTING SUBGRADEEXISTING SUBGRADE1' LEVEL AT TOP1' LEVEL AT TOP"NATIVE DETENTION AREA MIX" AS PREPARED BY:ERNST CONSERVATION SEEDS, INC.8884 MERCER PIKE, MEADVILLE, PA 16335PHONE: 800-873-3321 / 814-336-2404EMAIL: SALES@ERNSTSEED.COMWEBSITE: WWW.ERNSTSEED.COMAPPLICATION RATE: 1/2 LB. / 1000 SQ. FT. (20 LBS. / ACRE)MIX COMPOSITION:25.0% PANICUM VIRGATUM, 'SHELTER' (SWITCHGRASS, ‘SHELTER’)24.0% PANICUM CLANDESTINUM, 'TIOGA' (DEERTONGUE, ‘TIOGA’)22.0% CAREX VULPINOIDEA, PA ECOTYPE (FOX SEDGE, PA ECOTYPE)21.0% ELYMUS VIRGINICUS, PA ECOTYPE (VIRGINIA WILDRYE, PA ECOTYPE)6.0% AGROSTIS PERENNANS, ALBANY PINE BUSH-NY ECOTYPE (AUTUMN BENTGRASS,ALBANY PINE BUSH-NY ECOTYPE)1.0% JUNCUS EFFUSUS (SOFT RUSH)1.0% PANICUM RIGIDULUM, PA ECOTYPE (REDTOP PANICGRASS, PA ECOTYPE)66