HomeMy WebLinkAbout20220082_Porch Railing Modification - 65 Phila St Tamie Ehinger, Chair
Rob DuBoff, Vice Chair
Chris Bennett
Leslie DiCarlo
Jeff Gritsavage
Tad Roemer
Ellen Sheehan
Karen Cavotta, Alternate
Kennedy Flack, Alternate
CITY OF SARATOGA SPRINGS
DESIGN REVIEW BOARD
City Hall - 474 Broadway
Saratoga Springs, New York 12866
Tel: 518-587-3550 x.2517
www.saratoga-springs.org
NOTICE OF
ADMINISTRATIVE ACTION
In the matter of the request for administrative action relating to application
#20220082
Porch Railing Modification
65 Phila Street
Saratoga Springs, New York 12866
to approve the modified porch railing to include a steel booster rail with permanently affixed flower
box to provide code compliant guard as shown on the attached plans.
The Chairperson of the Design Review Commission finds that, in accordance with Section 13.9.G.2.i.,
Procedure of the Design Review Board, the requested action is not substantive in nature and is not
contrary to the intent of the original Board decision. Therefore, the request for administrative action, as
described above, is approved.
February 20, 2024
Date Chair
cc: Building Department File
(Applicant)
(Agent)
UP101 UP102
103
104
106
110
112
113
AA
A
A
A
A
A
A
A
A
C
C
DNDN
REINSTALL HISTORIC
COLUMNS CENTERED ON
PIERS BELOW AND
EXISTING BEAM ABOVE
REINSTALL HISTORIC
RAILING
INSTALL NEW 54" T & G
MAHOGANY DECKING.
BACK PRIME & STAIN
FINISH.
NEW 34" T & G APA RATED
FLOOR SHEATHING GLUED
& NAILED TO NEW FLOOR
JOISTS BELOW
INFILL EXISTING OPENING
W/ PT 2" x FRAMING
MATCHED TO DEPTH OF
EXISTING WALL. TOOTH IN
NEW SIDING MATCHED TO
EXISTING.
NEW WALL ASSEMBLY:
-NEW BACKPRIMED CEDAR
SIDING MATCHED TO EX.
-1/2" ZIP WALL SHEATHING
-2" x 6" STUDS @ 16" o.c.
1
A3.1
1
A3.2
EXISTING PORCH FRAMING TO REMAIN AS
PRACTICABLE. REPLACE ROTTED ELEMENTS IN
KIND AS REQUIRED. REINFORCE CONNECTIONS
W/ ANGLES OR HANGERS AS CONDITIONS
ALLOW.
SECURE EX. RIM TO EXISTING WALL W/
(1) TIMBERLOK SCREW @ EACH
STUD (TYP.)
SISTER 2" x 4" NAILERS @ TOP EDGE OF EX.
JOISTS TO PROVIDE SOLID NAILING FOR NEW
DECKING.2" x 10" JOISTS @ 18"o.c.4'-4"
2" x 4" OUTRIGGERS. FACE NAIL TO EX. STUDS @
NEW FLOOR JOISTS. IF FACE-LAPPING
OUTRIGGERS TO STUDS IS NOT PRACTICABLE,
PROVIDE A 2" x 4" LEDGER ACROSS I.F. OF
STUDS (NOT SHOWN). IF REQUIRED, FASTEN
LEDGER TO STUDS W/ (1) TIMBERLOK SCREW @
EACH STUD.
1/4"=1'-0"
FIRST FLOOR PLAN1
A1.1 SCALE: DATE: REVISIONS: A R C H I T E C T S 41 Long Alley Saratoga Springs, NY 12866 Phone: 518-584-7514 Fax: 518-584-7523A1.1REVIVE 6565 Phila StreetSaratoga Springs, NYFIRST FLOOR PLANFIRST FLOOR FRAMING PLAN1/4"=1'-0"5.23.231/4"=1'-0"
FIRST FLOOR FRAMING PLAN2
A1.1
T.O. FLOOR
EL= 100'-0"
T.O. SECOND FLOOR
EL= 109'-6-3/4"
B.O. CEILING
EL= 117'-5-3/4"
INSTALL NEW STANDING SEAM
METAL ROOF (CHARCOAL
GRAY)
SCRAPE, FILL, EPOXY SEAL,
AND PAINT EX. SIDING
54" x 54" LATTICE PANELS @
PORCH (TYP.)
REINSTALL HISTORIC
BALUSTRADE. NEW
BALUSTRADE TO MATCH
EXISTING WHERE REQUIRED.
NEW STAINED T & G DECK
REINSTALL HISTORIC
COLUMNS.
FURR EX. BEAM AS REQUIRED &
WRAP IN PAINTED 1" x CEDAR
INSTALL NEW WOOD T & G
CEILING (NOT SHOWN)
NEW STANDING SEAM ROOF
MATCHED TO MAIN ROOF
ABOVE
REFURBISH AND PAINT EX.
WINDOWS(TYP.)
@ ALL LOCATIONS WHERE GRADE
IS MORE THAN 30" BELOW DECK,
INSTALL 1"Ø STEEL BOOSTER RAIL
@ 36" ABOVE DECK. INSTALL
PERMANENTLY AFFIXED FLOWER
BOXES BETWEEN BOOSTER & T.O.
HISTORIC RAIL AS SHOWN SUCH
THAT NO GAP OF 4" OR MORE
EXISTS BELOW BOOSTER RAIL.
T.O. FLOOR
EL= 100'-0"
T.O. SECOND FLOOR
EL= 109'-6-3/4"
B.O. CEILING
EL= 117'-5-3/4"
INSTALL NEW STANDING SEAM
METAL ROOF (CHARCOAL
GRAY)
REPLACE (3) MISSING CORBELS
IN KIND
SCRAPE, FILL, EPOXY SEAL,
AND PAINT EX. SIDING
54" x 54" LATTICE PANELS @
PORCH (TYP.)
REINSTALL HISTORIC BALUSTRADE.
NEW BALUSTRADE TO MATCH
EXISTING WHERE REQUIRED.
NEW STAINED T & G DECK
REINSTALL HISTORIC
COLUMNS.
FURR EX. BEAM AS REQUIRED &
WRAP IN PAINTED 1" x CEDAR
INSTALL NEW WOOD T & G
CEILING (NOT SHOWN)
NEW STANDING SEAM ROOF
MATCHED TO MAIN ROOF
ABOVE
INSTALL (2) NEW WOOD
WINDOWS IN CRAWL SPACE
REFURBISH AND PAINT EX.
WINDOWS(TYP.)
@ ALL LOCATIONS WHERE GRADE
IS MORE THAN 30" BELOW DECK,
INSTALL 1"Ø STEEL BOOSTER RAIL
@ 36" ABOVE DECK. INSTALL
PERMANENTLY AFFIXED FLOWER
BOXES BETWEEN BOOSTER & T.O.
HISTORIC RAIL AS SHOWN SUCH
THAT NO GAP OF 4" OR MORE
EXISTS BELOW BOOSTER RAIL.
1/4"=1'-0"
PROPOSED WEST ELEVATION1
A2.1
1/4"=1'-0"
PROPOSED SOUTH ELEVATION2
A2.1 SCALE: DATE: REVISIONS: A R C H I T E C T S 41 Long Alley Saratoga Springs, NY 12866 Phone: 518-584-7514 Fax: 518-584-7523A2.1REVIVE 6565 Phila StreetSaratoga Springs, NYPROPOSED ELEVATIONS1/4"=1'-0"1.27.227.11.23