Loading...
HomeMy WebLinkAbout20240318 37 Clark Apt 8 Mini Split Revised ApplicationRevised 01/2021 $33/,&$7,21)25 $5&+,7(&785$/+,6725,&5(9,(: APPLICANT(S)* OWNER(S) (If not applicant) ATTORNEY/AGENT Name Address Phone / / / Email Identify primary contact person: † Applicant †Owner †Attorney/Agent * An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant’s interest in premises: †Owner †Lessee †Under option to lease or purchase PROPERTY INFORMATION Property Address/Location: Tax Parcel #: . - - (for example: 165.52 – 4 – 37 ) Current Zoning District: Property use: † Residential †Non-residential/mixed-use Type of Review: † Architectural †Historic †Extension/modification (of current approval) Summary description of proposed action: Has a previous application been filed with the DRC for this property? †No † Yes – date(s)? _____________________ -App. No.(s)? _________________ 'DWH$FTXLUHGE\2ZQHUBBBBBBBBBBBBBBBBB **HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED** CITY OF SARATOGA SPRINGS '(6,*15(9,(:&200,66,21 &,7<+$//%52$':$< 6$5$72*$635,1*61(:<25. 7(/; ZZZVDUDWRJDVSULQJVRUJ [FOR OFFICE USE] _____________BB $SSOLFDWLRQ  _________BB_ 'DWHUHFHLYHG  @@@@@@@@@@@@@@@@@@@@@@@@@@ 3URMHFW7LWOH 6WDII5HYLHZBBBBBBBBBBBBBBB **A “complete” application consists of  Kard copZ RULJLQDO , and 1 electronic copy of application & ALL other materials as required below: New Construction / Additions †Color photographs showing site/exterior details of existing structures and adjacent properties †Site plan, drawn to scale, showing existing & proposed construction, property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.); on no larger than 2’x3’ sheet – smaller preferred if legible †Elevation drawings showing design of all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible †Floor plans for proposed structure; on sheet no larger than 2’x3’ – smaller permitted if legible †Product literature, specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) †Color photographs showing site/exterior details of existing structures and that illustrate affected features †Elevation drawings showing all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible †Product literature, specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts only (Front setbacks: UR-1 & INST-HTR=30’; UR-4=25’; UR-2, UR-3 & NCUD-1=10’) -Installation, removal or change in material of drive- and walkways -Installation or removal of architectural, sculptural or vegetative screening over 3’ in height -Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2’ diameter) For any of above: †Color photographs showing site/exterior details of existing structures, and of adjacent properties †Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2’x3’ sheet – smaller preferred if legible †Product literature, specifications and samples of proposed materials and colors Signage / Awnings †Color photographs showing site/exterior details of existing structures, and adjacent properties †Plan showing location of proposed sign/awning structure on building/premises: no larger than 11”x17” †Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware †Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location †Product literature, specifications and samples of proposed materials and colors Demolition †Color photographs showing site/exterior details of existing structures, and of adjacent properties †Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale †Written description of reasons for demolition and, in addition: †For structures of “architectural/historical significance”, demonstrate “good cause” why structure cannot be preserved †For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a “contributing” structure in a National Register district (contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities †Color photographs showing site/existing structures, and of adjacent properties †Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale †Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details †Consult Article 240-12.22 of the City’s Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 01/2021 Revised 01/2021 Request for extension of current approval †Identify date of original DRC approval: ______________Current expiration date: ________________ Org. App. No. ____________ †Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEQR Environmental Assessment Form †Applicants proposing the following must complete “Part I” of the SEQR Short Environmental Assessment Form (available here: http://www.dec.ny.gov/docs/permits_ej_operations_pdf/seafpartone.pdf): -Construction or expansion of a multi-family residential structure (4 units +) -Construction or expansion (exceeding 4,000 sq. ft. gross floor area) of a principal or accessory non-residential structure -Telecommunications facility, radio antennae, satellite dishes -Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? †No † Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification I/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Commission. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review of the Zoning Code of the City of Saratoga Springs. Date: (applicant signature) Date: (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature: Date: Owner Signature: Date: Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # Page 1 of 4 Indoor Unit Compatibility Will only operate with Samsung evaporator model numbers: AR**TSFABWKNCV (RNS**ABT): 7,000 - 24,000 Btu/h models AR**BSFCMWKNCV (RNS**CMB): 7,000 - 24,000 Btu/h models AR**TSFYBWKNCV (RNS**YBT): 7,000 - 24,000 Btu/h models AC0**BNNDCH/AA (CNH**NDB): 9,000 - 18,000 Btu/h models AC0**BN1DCH/AA (CNH**1DB): 9,000 - 12,000 Btu/h models AC0**BNJDCH/AA (CNH**JDB): 9,000 - 18,000 Btu/h models AC0**BNLDCH/AA (CNH**LDB): 9,000 - 18,000 Btu/h models AC0**BNZDCH/AA (CNH**ZDB): 12,000 - 18,000 Btu/h models AJ0**BNHDCH/AA (JNH**HDB): 9,000 - 18,000 Btu/h models General Information •The Samsung Max Heat system shall provide high heating capacity at -13°F outside temperature •The outdoor unit shall supply power individually to the indoor units via 14 AWG X 3 power wire •The outdoor unit shall have a base pan heater as standard to ensure optimal defrost cycle water drainage • Auto-restart after power loss •Available maximum current setting option to reduce operating current. •System energy consumption can be viewed using Samsung SmartThings mobile app (not revenue grade, for reference only). • Soft-start to reduce current demand during compressor start Construction •The outdoor unit shall be galvanized steel with a baked on powder coated finish for durability Heat Exchanger •The heat exchanger shall be mechanically bonded fin to copper tube Controls • Control signal shall be a DDC type signal • Interconnect control wire between outdoor and indoor units shall be 16AWG X 2 • Controls shall integrate with a BMS system • The system shall integrate with the Samsung Controls solution Refrigerant System • The refrigerant shall be R410A • The compressor shall be hermetically sealed, inverter controlled, Twin BLDC Rotary •Refrigerant flow shall be controlled by 4 separate electronic expansion valves at outdoor unit • Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and (excluding ductless systems) must be matched with appropriate coil components to meet ENERGY STAR® criteria. Ask your contractor for details or visit www.energystar.gov.  ZZZSamsungHVACFRP Factory Charge 119.9 oz Charged for 131 ft Additional Refrigerant 0.22 oz/ft over 131 ft Heat Exchanger Type Aluminum Fin - Copper Tube Refrigerant Type R410A Control Method Electronic Expansion Valve Compressor Type Twin BLDC Rotary Inverter RLA Amps 18.4 Included Pipe Adapters 2 - 1/2" X 3/8" Condenser Fan Motor BLDC With Propeller Fan (1) Output Watts / FLA 125 / 1.28 CFM 2,493 Maximum Individual Line Set Length 82 ft Maximum Line Set Length (total)230 ft Maximum Vertical Separation Outdoor to Indoor 49 ft Highest to lowest indoor 25 ft Operating Temperatures Cooling 14 ~ 114.8°F (-10 ~ 46.0°C) Heating -13 ~75°F (-25 ~ 24.0°C) Pipe Connections High Side 1/4" X 4 Low Side (suction)3/8" X 2 + 1/2" X 2 173.1 Noise Level Cooling dB (A)54 Heating dB (A)58 Amps 30 Minimum Circuit Ampacity (A)26.0 Dimensions W X H X D Inches 37 x 39 5/16 x 13 Weight lbs. Power Voltage (ø/V/Hz)1 / 208-230 / 60 Nominal Current3 Cooling (A)10.9 Heating (A)10.0 Max. Breaker Model US Code JXH30S4B Model Number AJ030BXS4CH/AA Auto or manual addressing of indoor units WBB-11M Accessories Wall Bracket CKN-250 Wind Baffle Front WBF-2M-B Back Samsung "Max Heat" FJM Series, 4 Port Condensing Unit SUBMITTAL AJ030BXS4CH/AA (JXH30S4B) © 2022 Samsung HVAC SHA-FJM-*S030-2212A 1Performance data certified by AHRI to AHRI 210-240 (2017) with Addendum 1. 2Performance data certified by AHRI to AHRI 210-240 (2023). Effective January 1st, 2023. 3Rated current based on highest combination ratio of non-ducted indoor units. This publication reflects both the 1987 Appendix M metric (SEER) and the 2023 Appendix M1 metric (SEER2). Efficiency requirements are published at 10 C.F.R. 430.32(c).y Please refer to www.AHRInet.org for more information about energy metrics. Samsung HVAC maintains a policy of ongoing development. Specifications are subject to change without notice. Refer to www.AHRIdirectory.org for current reference numbers. Warranty 10 Years compressor, 10 year parts, 1 year limited labor (registration required) ENERGY STAR® Certification Applies to AHRI non ducted listingCertificationsSafetyETL (UL 60335-2-40) Performance Capacity (min. / standard / max.) Cooling (Btu/h)6,500 / 28,400 / 28,400 Heating (Btu/h)7,500 / 28,600 / 28,600 SEER (Ducted / Mixed / Non-ducted)1 17.0 / 18.0 / 19.0 EER (Ducted / Mixed / Non-ducted)1 10.5 / 11.5 / 12.5 HSPF (Ducted / Mixed / Non-ducted)1 9.8 / 10.4 / 11.0 SEER2 (Ducted / Mixed / Non-ducted)2 EER2 (Ducted / Mixed / Non-ducted)2 HSPF2 (Ducted / Mixed / Non-ducted)2 17.5 / 18.75 / 20.0 10.5 / 11.5 / 12.5 8.3 / 8.65 / 9.0 Heating Capacity at 5°F OA, 70°F Indoor DB (Btu/h) Heating Capacity at -13°F OA, 70°F Indoor DB (Btu/h) 28,600 20,000 Page 2 of 4 Samsung "Max Heat" FJM Series, 4 Port Condensing Unit Dimensional drawing SUBMITTAL AJ030BXS4CH/AA (JXH30S4B) No.Name Description 1 Refrigerant suction pipes ø3/8" x 2, ø1/2" x 2 2 Refrigerant liquid pipes ø1/4" x 4 3 Service Valve (suction)5/8" 4 Service Valve (liquid)3/8" 5 Drain holes Connection with provided drain fitting TOP FRONT RIGHTLEFT BOTTOM BACK 24 7/16"13"14 3/16"15 1/8"39 5/16"38 3/16"7 3/16" 3 3/4" 8 5/8"15 7/16"1 3/16"14 3/4"12 3/16"9 5/8"7 1/16"3/4" 1 9/16"5 3/4"8 5/16"10 15/16"13 1/2"1 2 3 4 5 37"1"Power and Communication Wiring conduit  ZZZSamsungHVACFRP Page 3 of 4 Samsung "Max Heat" FJM Series, 4 Port Condensing Unit Indoor unit connection options SUBMITTAL AJ030BXS4CH/AA (JXH30S4B) Indoor Unit Connection Options A B C D Duct S MPAH 7 7 14 7 9 •16 7 12 • •19 7 15 •22 7 18 • •25 7 24 •31 9 9 •18 9 12 • •21 9 15 •24 9 18 • •27 9 24 • •33 12 12 • •24 12 15 • •27 12 18 • •30 12 24 • •36 15 15 •30 15 18 • •33 15 24 39 18 18 • •36 7 7 7 21 7 7 9 23 7 7 12 26 7 7 15 •29 7 7 18 • •32 7 7 24 •38 7 9 9 • •25 7 9 12 28 7 9 15 •31 7 9 18 • •34 7 9 24 •40 7 12 12 • •31 7 12 15 34 7 12 18 • •37 9 9 9 • •27 9 9 12 30 9 9 15 33 9 9 18 36 9 12 12 33 9 12 15 36 9 12 18 39 12 12 12 •36 12 12 15 • •39 7 7 7 7 •28 7 7 7 9 • •30 7 7 7 12 33 7 7 7 15 • •36 7 7 7 18 • •39 7 7 9 9 32 7 7 9 12 35 7 7 9 15 38 7 7 12 12 38 7 9 9 9 34 7 9 9 12 37 7 9 9 15 • •40 7 9 12 12 40 9 9 9 9 36 9 9 9 12 39 4 3 2 Unit Qty. Indoor Nominal Capacity (K Btu/h) Duct S / MPAH Compatibility* Connected Capacity (K Btu/h) * 1. 2. 3. Notes Combatable combination that includes 1 X MPAH (AC0**BNZDCH/AA) OR 1 X Duct S (AJ0**BNHDCH/AA) unit. Only 1 X MPAH (AC0**BNZDCH/AA) OR 1 X Duct S (AJ0**BNHDCH/AA) unit can be connected to a single FJM outdoor unit. Applies to outdoor units manufactured after 4/30/2022. Refer to supporting technical data book (TDB) for indoor unit compatibility available at www.SamsungHVAC.com.  ZZZSamsungHVACFRP Page 4 of 4 Samsung "Max Heat" FJM Series, 4 Port Condensing Unit Wiring example SUBMITTAL AJ030BXS4CH/AA (JXH30S4B) Basic Wire Connection Diagram Cable Type: System power supply cable Cable Type: Power supply to indoor units Cable Type: Communication cable (16 X 2) A B C This simple wiring diagram is for reference only. Please refer to installation manuals for full details and requirements. L1 L2 L1 L2 L1 F2 1 2 F1 F2 1 2 F1 F2 F1 F2 F1 F2 F1 F2 1 2 21 1 2 B C B C B C A F1 F2 F1 F2 F1 F2 L1 L2 21 21 Earth F1 F2 F1 F2 1 2 B C 21 Earth terminal Outdoor unit Main Power Supply cable Indoor unitA-unit B-unit C-unit D-unit Earth terminal Earth terminalEarth terminalterminal L2 F1 L1 F2L2F1 L1 F2L2F1 L1 F2L2F1 Outdoor unit  ZZZSamsungHVACFRP