Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20240257 235 Washington Mini Split Application
SARATOGA SPRINGS, NY 12866 818-272-8810 AMCDONALD@IPERMITUSA.COM ANNE GRIFFIN (WASHINGTON CENTRIAL LLC) 235 WASHINGTON ST SARATOGA SPRINGS, NY 12866 518-694-1338 ADMIN@SARATOGAVISION.COM X X 235 Washington Street, Saratoga Springs, NY, 12866 165.14 1 11.1 T4 X ADD ON 3/4 TON 14 SEER MITSUBISHI MINISPLIT TO THE FRONT YARD W/ ELECTRICAL Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Job Name: System Reference:Date: FEATURES • Compatible with M- and P-Series and CITY MULTI® indoor units. Branch box required for connection with M- and P-Series • Variable speed INVERTER-driven compressor • Seacoast protection on heat exchanger and base panel (rated for 2,000 hrs in accordance with ASTM B117 testing) • Thermal Differential 1°F (with PAC-MKA32/52BC only) • Built-in base pan heater • Quiet outdoor unit operation, rated sound pressure as low as 51 dB(A) • High pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection • Hyper-heating performance offers 100% heating capacity at 5°F and 75% heating capacity at -13°F MXZ-SM48NAMHZ4-TON MULTI-ZONE INVERTER HEAT-PUMP SYSTEM ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: MXZ-SM48NAMHZ test Cooling1 (Non-Ducted // Mix // Ducted) Maximum Capacity BTU/H 48,000 // 48,000 // 48,000 Rated Capacity BTU/H 48,000 // 48,000 // 48,000 Minimum Capacity BTU/H 16,000 // 16,000 // 16,000 Maximum Power Input W 3,665 // 3,930 // 4,245 Rated Power Input W 3,665 // 3,930 // 4,245 Power Factor (208V, 230V)%98.5, 98.5 // 98.5, 98.5 // 98.5, 98.5 Heating at 47°F2 (Non-Ducted // Mix // Ducted) Maximum Capacity BTU/H 54,000 // 54,000 // 54,000 Rated Capacity BTU/H 54,000 // 54,000 // 54,000 Minimum Capacity BTU/H 27,000 // 27,000 // 27,000 Maximum Power Input W 3,955 // 4,335 // 4,795 Rated Power Input W 3,955 // 4,335 // 4,795 Power Factor (208V, 230V)%98.5, 98.5 // 98.5, 98.5 // 98.5, 98.5 Heating at 17°F3 (Non-Ducted // Mix // Ducted) Maximum Capacity BTU/H 54,000 // 54,000 // 54,000 Rated Capacity BTU/H 39,000 // 39,000 // 39,000 Maximum Power Input W 6,330 // 7,750 // 8,600 Rated Power Input W 4,230 // 4,680 // 5,130 Heating at 5°F4 (Non-Ducted // Mix // Ducted) Maximum Capacity BTU/H 54,000 // 54,000 // 54,000 Maximum Power Input W 7,915 // 8,120 // 8,330 Efficiency (Non-Ducted // Mix // Ducted) SEER 23.0 // 19.75 // 16.5 EER1 13.1 // 12.2 // 11.3 HSPF (IV)12.0 // 11.5 // 11.0 COP at 47°F2 4.0 // 3.65 // 3.3 COP at 17°F at Maximum Capacity3 2.5 // 2.0 // 1.8 COP at 5°F at Maximum Capacity4 2.1 // 1.95 // 1.9 ENERGY STAR® Certified Yes // No // No Electrical Electrical Power Requirements Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range V AC 187-253 Voltage: Indoor - Outdoor, S1-S2 V AC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR)kA 5 Recommended Fuse/Breaker Size if Branch Box Powered by Outdoor Unit A 40 (45) Recommended Fuse/Breaker Size without Branch Box or Branch Box Powered Separate A 40 Recommended Wire Size AWG 6 MCA if Branch Box Powered by Outdoor Unit A 42.0 MOCP if Branch Box Powered by Outdoor Unit A 50 MCA without Branch Box or Branch Box Powered Separate A 36 MOCP without Branch Box or Branch Box Powered Separate A 40 Fan Motor Full Load Amperage A 0.6+0.6 Outdoor unit Airflow Rate (Cooling / Heating)CFM 3,885 / 3,885 Refrigerant Control LEV Defrost Method Reverse Cycle Heat Exchanger Type Plate fin coil Heat Exchanger Coating Blue Fin Coating Sound Pressure Level, Cooling1 dB(A)51 Sound Pressure Level, Heating2 dB(A)54 Compressor Type Hermetic Compressor Model ANB33FJSMT Compressor Motor Output kW 3.4 Compressor Rated Load Amps A 19 Compressor Locked Rotor Amps A 22.0 Compressor Oil Type // Charge oz.FV50S // 73 Base Pan Heater Built-in Unit Dimensions W: In. [mm]41-11/32 [1,050] D: In. [mm]13 [330] H: In. [mm]52-11/16 [1,338] Package Dimensions W: In. [mm]43 [1,090] D: In. [mm]18 [450] H: In. [mm]57 [1,430] Unit Weight Lbs.[kg]278 [126] Package Weight Lbs.[kg]302 [137] NOTES: AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. *A when 1 or more PLA-A·EA7 connected *B Branch box should be placed within the level between the outdoor unit and indoor units *C 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. SPECIFICATIONS: MXZ-SM48NAMHZ Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum*)°FDB 115 / 23*C Cooling Thermal Lock-out / Re-start Temperatures °FDB N/A / N/A Heating Intake Air Temp (Maximum / Minimum)°FDB 59 / -13 Heating Thermal Lock-out / Re-start Temperatures °FDB -24 / -14 Refrigerant Maximum Charge Quantity Lbs, oz 10.0, 9.0 Indoor unit connection Maximum Number of Connected IDU with Branch Box 8 (6)*A Maximum Number of Connected IDU without Branch Box 12 Minimum Number of Connected IDU with Branch Box 12,000 Minimum Number of Connected IDU without Branch Box 24,000 Maximum connected capacity 62,000 Piping Liquid Pipe Size O.D. (Flared)In.[mm]3/8 [9.52] Gas Pipe Size O.D. (Flared)In.[mm]5/8 [15.88] Total Piping Length when using Branch Box Ft. [m]492 [150] Total Piping Length without Branch Box Ft. [m]984 [300] Maximum Height Difference*B, ODU above IDU Ft. [m]164 [50] Maximum Height Difference*B, ODU below IDU Ft. [m]131 [40] Maximum Height Difference*B, between branch boxes Ft. [m]49 [15] Maximum Height Difference between IDU and IDU without branch box Ft. [m]49 [15] Ft. [m]49 [15] Maximum Piping Length between ODU and Branch Box Ft. [m]180 [55] Farthest Piping Length from ODU to IDU with Branch Box Ft. [m]262 [80] Farthest Piping Length from ODU to IDU without Branch Box Ft. [m]492 [150] Farthest Piping Length after Branch Box Ft. [m]82 [25] Total Piping Length between Branch Boxes and IDU Ft. [m]311 [95] Maximum Number of Bends for IDU 15 NOTES: AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. *A when 1 or more PLA-A·EA7 connected *B Branch box should be placed within the level between the outdoor unit and indoor units *C 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Deflector Vertical Air Deflector ADV-1 Air Outlet Guide Air Outlet Guide (1 Piece) PAC-SH96SG-E (two pieces are required) Ball Valve Refrigeration Ball Valve - 1/2” BV12FFSI2 Refrigeration Ball Valve - 1/4” BV14FFSI2 Refrigeration Ball Valve - 3/8” BV38FFSI2 Refrigeration Ball Valve - 5/8” BV58FFSI2 Branch Box 3 Port Branch Box PAC-MKA32BC 5 Port Branch Box PAC-MKA52BC Branch Box Enclosure BBE-1 Centralized Drain Pan Central Drain Pan PAC-SH97DP-E Control Wire M-Net Control Wire, 1,000’ Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) CW162S-1000 M-Net Control Wire, 250’ Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) CW162S-250 Control/Service Tool Maintenance Tool Interface PAC-USCMS-MN-1 Distribution pipe Brazed Connection MSDD-50BR-E Flare Connection MSDD-50AR-E Drain Socket Drain Socket PAC-SG60DS-E Hail Guards Hail Guard HG-A2 Mini-Split Wire 14 Gauge, 4 wire MiniSplit Cable—250 ft. roll S144-250 14 Gauge, 4 wire MiniSplit Cable—250 ft. roll SW144-250 14 Gauge, 4 wire MiniSplit Cable—50 ft. roll S144-50 14 Gauge, 4 wire MiniSplit Cable—50 ft. roll SW144-50 16 Gauge, 4 wire MiniSplit Cable—250 ft. roll S164-250 16 Gauge, 4 wire MiniSplit Cable—250 ft. roll SW164-250 16 Gauge, 4 wire MiniSplit Cable—50 ft. roll S164-50 16 Gauge, 4 wire MiniSplit Cable—50 ft. roll SW164-50 Mounting Pad Condensing Unit Mounting Pad: 24” x 42” x 3” ULTRILITE2 Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic DSD-400P Port Adapter Adaptor: 1/2” x 3/8” MAC-A455JP-E Adaptor: 1/2” x 5/8” MAC-A456JP-E Adaptor: 3/8” x 1/2” MAC-A454JP-E Adaptor: 3/8” x 5/8” PAC-SG76RJ-E Stand 18” Dual Fan Stand QSMS1802M 24” Dual Fan Stand QSMS2402M Condenser Wall Bracket QSWB2000M-1 Condenser Wall Bracket - Stainless Steel Finish QSWBSS Outdoor Unit Stand — 12” High QSMS1202M Wind Baffle Front Wind Baffle WB-PA3 (two pieces are required) OUTDOOR UNIT ACCESSORIES: MXZ-SM48NAMHZ Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. FORM# MXZ-SM48NAMHZ - 202209 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Unit: mm <inch>110<4-11/32>45<1-25/32>81<3-3/16>86<3-3/8>26<1-1/32>369<14-17/32>632<24-7/8>1338<52-11/16>362<14-1/4>1050<41-11/32>330<13>25<1>ɹɹɹ 370<14-9/16>28<1-3/32>19<3/4>417<16-13/32>42<1-21/32>60.5<2-3/8><1-37/64>400<2-7/32>56<2-3/32>53974<38-11/32>Example of Notes• • • Refrigerant GAS pipe connection (FLARE)A12• • • Refrigerant LIQUID pipe connection (FLARE)9.52 (3/8F)• • • Indication of STOP VALVE connection location.Handle for movingHandle formovingService panelGround for the power supply(*GR*marking position)Ground for the transmission lineGround for concentration controlFor thepower supplyFor thebranch boxpower supplyFor thetransmission lineFor concentrationcontrolTerminal connectionFrom left to right12Rear piping coverFront piping coverAir IntakeBottom piping hole(Knock-Out)Drain hole(5X33<1-5/16>)160<6-5/16>160<6-5/16>160<6-5/16>136<5-11/32>154<6-1/16>Instllation Feet600<23-5/8>225<8-27/32>225<8-27/32>70<2-3/4>2XU Shaped notched holes(Foundation Bolt M10<W3/8>)2X12X36 Oval holes(Foundation Bolt M10<W3/8>)Side Air IntakeRear Air IntakeAir DischargeSide Air IntakeHandle formovingRear Air IntakeHandle formoving60<2-3/8>55<2-3/16>55<2-3/16>27<1-1/16>92<3-5/8>75<2-15/16>26<1-1/32>73<2-7/8>92<3-5/8>55<2-3/16>29<1-5/32>27<1-1/16>26<1-1/32>53<2-3/32>60<2-3/8>5<3/16>60<2-3/8>73<2-7/8>5<3/16>55<2-3/16>27<1-1/16>60<2-3/8>73<2-7/8>26<1-1/32>75<2-15/16>92<3-5/8>60<2-3/8>55<2-3/16>60<2-3/8>24<15/16>101.5<4>5<3/16>24.7<31/32>Piping Knock-Out Hole DetailsWhen installing the conduit.Set the attachment to theinner side of each panel.1 inch Conduitattachment34.5<1-23/64>22.2<7/8>1/2 inch ConduitattachmentScale 1:5mm <inch>Conduit hole(24<15/16>Knock-Out)Conduit hole(37<1-15/32>Knock-Out)Front piping hole(Knock-Out)92<3-5/8>60<2-3/8>5<3/16>Right piping hole(Knock-Out)Conduit hole(24<15/16>Knock-Out)Conduit hole(37<1-15/32>Knock-Out)Right trunking hole(Knock-Out)92<3-5/8>92<3-5/8>Rear piping hole(Knock-Out)Conduit hole(37<1-15/32>Knock-Out)Conduit hole(24<15/16>Knock-Out)Rear trunking hole(Knock-Out)92<3-5/8>Max.30<1-3/16>3 FOUNDATION BOLTSPlease secure the unit firmlywith 4 foundation (M10<W3/8>) bolts.(Bolts and washers must be purchased locally.)4 PIPING-WIRING DIRECTIONSPiping and wiring connectionscan be made from 4 directions:Front, Right, Rear and Below.Service space<Foundation bolt height>FOUNDATION1 FREE SPACE(Around the unit)The diagram below shows a basic example.Explanation of particular details aregiven in the installation manuals etc.Min.15mm<19/32>Min.15mm<19/32>FREEMin.1000mm<39-3/8>Min.150mm<5-29/32>2 SERVICE SPACEDimensions of space neededfor service access areshown in the below diagram.Min.500<19-11/16>Min.500<19-11/16>*1*1B*1CMXZ-SM36NAMHZMXZ-SM42NAMHZMXZ-SM48NAMHZMXZ-SM60NAMMXZ-SM36NAMMXZ-SM48NAMMODEL NAMEDIMENSION ADIMENSION BDIMENSION C15.88 (5/8F)19.05 (3/4F)15.88 (5/8F)426 <16-25/32>393 <15-15/32>426 <16-25/32>485 <19-3/32>450 <17-23/32>485 <19-3/32>OUTDOOR UNIT DIMENSIONS: MXZ-SM48NAMHZ