Loading...
HomeMy WebLinkAbout20240251 Wendy's 24 Congress Exterior Modification ApplicationDRIVETHRU THIS SIGN TYPICAL AT ALL ACCESSIBLEPARKING SPACES. USE USTRANSPORTATION DEPT/ SIGN R7-8UNLESS THERE ARE STATE SPECIFICREQUIREMENTSTHIS SIGN TYPICAL AT ALL VANACCESSIBLE PARKING SPACESPENALTY SIGN w/ WORDING ASREQ'D BY STATE OR LOCALLAW WHEN REQUIREDUSE US TRANSPORTATIONDEPT. SIGN R7-8A AT VANACCESSIBLE PARKING SPACES6" PLASTIC BOLLARD SLEEVE/IF SIGN IS IN LANDSCAPE AREA,SIGN POST WILL BE DRIVENINTO GROUND MIN 36"PARKING GRADE4'-0" 5'-0" SEALDESCRIPTIONDATEREV.DRAWN BYCHECKED BYSHEET NAMESHEET NUMBER4/3/2024, 9:41 AM, P:\2023\23395 - CKA - Wendy's - Saratoga Springs, NY\Sheet Sets\2024-03-14 Permit\AS1.1 SITE PLAN.dwg, chavez NOTICE: THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION. IT SHALL NOT BEUSED OR REPRODUCED OR ITS CONTENTSDISCLOSED , IN WHOLE OR IN PART WITHOUTTHE PRIOR WRITTEN CONSENT OF WALLIN /GOMEZ ARCHITECTS, LTD.THESE DRAWINGS HAVE BEEN PREPARED ATAND / OR UNDER MY SUPERVISION AND TO THEBEST OF MY KNOWLEDGE AND BELIEFCONFORM AND COMPLY WITH THEREQUIREMENTS OF THE DEPARTMENT OFBUILDING AND CODES HAVING JURISDICTION.REGISTERED ARCHITECTSTATE OF 711 South Dearborn Street, Suite 606Chicago, Illinois 60605-1827P: 312-427-4702 n F: 312-427-6611E: ADMIN@WGALTD.COM1234567PLOT DATE: 4.3.2024PROJECT NUMBER: 23395DONALD J. WALLINEXPIRATION DATE: AUGUST 31, 2026NEW YORKVCDJW03294604233 24 CONGRESS ST. SARATOGA SPRINGS, NY 12866AS1.1SITE PLAN1/30/244/3/24-----ISSUED FOR PERMIT-----DESIGN SETN01SITE PLANSCALE: 1" = 20'CONGRESS ST.(E) 1 STORYBUILDING(E) CONCRETE PADSITE NUMBER:BASE MODEL:OWNER:BASE VERSION:DESIGN BULLETINS:PROJECT YEAR:ASSET TYPE:CLASSIFICATION:UPGRADE CLASSIFICATION:FURNITURE PACKAGE:042334058FRANCHISEREFRESH-LITECKA2023 JANSTANDARD BASE202420232023(E) DUMPSTERS (E) MENU BOARD(E) OCB W/ SPEAKER NREFTRUE(E) LIGHT POLE(E) LIGHT POLE(E) LIGHT POLEREFACE (E)PYLON SIGN(E) LIGHTSBUN FREEZER(E) TRANSFORMER(E) MERCHADISER(D) TRASHRECEPTACLE(N) ADA PARKINGSIGNS(E) TRASH ENCLOSURE AND GATES-REPAIR & PAINT (PEX-1) (E) SAFELY RAILING-PAINT (PEX-10) (E) CURB RAMP (E) CURB RAMP(E) ADA SYMBOLS(E) PATIOFURNITURE (N) CURB RAMP-REMOVE (E) SIDEWALK(E) ELEC METER-(PAINT PEX-1) (N) ADA CROSSWALK LINE OF (E) SOLARIUM TO BE REMOVEDPROVIDE (N) LANDSCAPING ROCK TOMATCH EXISTING(E) LIGHT POLE(E) LIGHT POLE(E) SIDEWALK & RAMP5'-0"FOR ALL NEW RAMPS, MAX SLOPE INDIRECTION OF TRAVEL TO BE 1:12 (8.33%).- MAX CROSS SLOPE TO BE 1:50 (2%).- FOR ADA PARKING STALL AND AISLES, MAXSLOPE IN DIRECTION OF TRAVEL TO BE 1:20(5%). MAX CROSS SLOPE TO BE 1:48 (2%)02ADA SIGN DETAILSCALE: 1/4" = 1'-0" (E) WALL PANELINGTO BE REMOVED(E) CHAIR RAILTO BE REMOVED(E) CARPET & BASE TILE TOBE REMOVED(E) WALL TO BE PREPPEDFOR (N) PAINT(E) WALL TO BE PREPPEDFOR (N) PAINT(E) SILL TO BEREMOVED(E) CORNICE TO REMAINDININGROOM101BSITE NUMBER:BASE MODEL:OWNER:BASE VERSION:DESIGN BULLETINS:PROJECT YEAR:ASSET TYPE:CLASSIFICATION:UPGRADE CLASSIFICATION:FURNITURE PACKAGE:042334058FRANCHISEREFRESH-LITECKA2023 JANSTANDARD BASE202420232023 SEALDESCRIPTIONDATEREV.DRAWN BYCHECKED BYSHEET NAMESHEET NUMBER4/3/2024, 9:41 AM, P:\2023\23395 - CKA - Wendy's - Saratoga Springs, NY\Sheet Sets\2024-03-14 Permit\D1.1 DEMOLITION FLOOR PLAN.dwg, chavez NOTICE: THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION. IT SHALL NOT BEUSED OR REPRODUCED OR ITS CONTENTSDISCLOSED , IN WHOLE OR IN PART WITHOUTTHE PRIOR WRITTEN CONSENT OF WALLIN /GOMEZ ARCHITECTS, LTD.THESE DRAWINGS HAVE BEEN PREPARED ATAND / OR UNDER MY SUPERVISION AND TO THEBEST OF MY KNOWLEDGE AND BELIEFCONFORM AND COMPLY WITH THEREQUIREMENTS OF THE DEPARTMENT OFBUILDING AND CODES HAVING JURISDICTION.REGISTERED ARCHITECTSTATE OF 711 South Dearborn Street, Suite 606Chicago, Illinois 60605-1827P: 312-427-4702 n F: 312-427-6611E: ADMIN@WGALTD.COM1234567PLOT DATE: 4.3.2024PROJECT NUMBER: 23395DONALD J. WALLINEXPIRATION DATE: AUGUST 31, 2026NEW YORKVCDJW03294604233 24 CONGRESS ST. SARATOGA SPRINGS, NY 12866D1.1DEMOLITIONFLOOR PLAN1/30/244/3/24-----ISSUED FOR PERMIT-----DESIGN SET02PARTIAL INTERIOR ELEVATIONSCALE: 1/4" = 1'-0"N01DEMOLITION FLOOR PLANSCALE: 1/4" = 1'-0"DEMOLITION GENERAL NOTES1.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION WORK REQUIRED TOIMPLEMENT NEW WORK, AS SHOWN ON OTHER DRAWINGS. THIS PAN INDICATES ONLY THEAPPROXIMATE DEMOLITION REQUIRED FOR COMPLETION OF THIS REMODEL. EXISTING CONDITIONSNOT SHOWN OR NOTED SHALL REMAIN UNCHANGED UNLESS APPROVED BY THE ARCHITECT OROWNER'S REPRESENTATIVE. ALL EXISTING MATERIALS ADJACENT TO THE NEW CONSTRUCTION SHALLBE PATCHED, REPAIRED, AND FINISHED TO PROVE A SMOOTH, LEVEL, AND UNNOTICEABLE TRANSITIONBETWEEN NEW AND EXISTING FINISHES.2.CONTRACTOR SHALL VERIFY FIELD CONDITIONS AND NOTIFY WENDY'S REPRESENTATIVE ANDARCHITECT OF ALL DISCREPANCIES BEFORE PROCEEDING WITH WORK.3.PREVENT MOVEMENT OR SETTLEMENT OF STRUCTURE(S). PROVIDE AND PLACE BRACING OR SHORINGTO ENSURE SAFETY AND SUPPORT OF STRUCTURE. G.C. TO ASSUME LIABILITY FOR SUCH MOVEMENT,DAMAGE, OR INJURY.4.CEASE OPERATIONS AND NOTIFY THE WENDY'S REPRESENTATIVE IMMEDIATELY IF SAFETY OFSTRUCTURE APPEARS TO BE COMPROMISED. TAKE PRECAUTIONS TO PROPERLY SUPPORTSTRUCTURE. DO NOT RESUME OPERATIONS UNTIL SAFETY IS RESTORED.5.PROVIDE, ERECT, AND MAINTAIN BARRICADES, LIGHTING, AND GUARD RAILS AS REQUIRED BYAPPLICABLE CODES TO PROTECT OCCUPANTS OF BUILDING, WORKERS, AND PEDESTRIANS.6.BEFORE DISCONNECTING, REMOVING, AND CAPPING UTILITY SERVICES WITHIN AREAS OF DEMOLITION,NOTIFY THE LOCAL UTILITY COMPANY AND WENDY'S REPRESENTATIVE IN ADVANCE AND OBTAINAPPROVAL BEFORE STARTING THE WORK.7.HVAC SUBCONTRACTOR TO INSPECT EXISTING CONDITIONS PRIOR TO DEMOLITION, AND DETERMINEWHETHER ANY COMPRESSOR REFRIGERANT LINES ARE PRESENT THAT MUST BE PROPERLY DRAINED(TO E.P.A. STANDARDS) PRIOR TO DEMOLITION.8.PLACE MARKERS TO INDICATE LOCATION OF DISCONNECTED SERVICES. IDENTIFY SERVICE LINES ANDCAPPING LOCATIONS ON PROJECT RECORD DOCUMENTS.9.EXCEPT WHERE NOTED OTHERWISE, MAINTAIN POSSESSION OF MATERIALS BEING DEMOLISHED.IMMEDIATELY REMOVE FROM SITE.10.DEMOLISH IN AN ORDERLY AND AS CAREFUL MANNER AS REQUIRED TO ACCOMMODATE NEW WORK,INCLUDING THAT REQUIRED FOR CONNECTION TO THE EXISTING BUILDING. PROTECT EXISTINGFOUNDATIONS AND SUPPORTING STRUCTURAL MEMBERS.11.PERFORM DEMOLITION IN ACCORDANCE WITH APPLICABLE AUTHORITIES HAVING JURISDICTION.12.REPAIR ALL DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED, AT NO COST TO OWNER.13.BURNING OF MATERIALS ON SITE IS NOT PERMITTED.14.REMOVE DEMOLISHED MATERIALS, TOOLS, AND EQUIPMENT FROM SITE UPON COMPLETION OF WORK.LEAVE SITE IN CONDITION ACCEPTABLE TO WENDY'S REPRESENTATIVE.15.WENDY'S VENDOR TO REMOVE ALL F.F.& E. PRIOR TO G.C.'S DEMOLITION START. G.C. TO PROTECT ANDSHRINK-WRAP REMAINING F.F.& E. NOT AFFECTED BY REMODEL. G.C. TO COORDINATE WITH WENDY'SREPRESENTATIVE.16.PRIOR TO BID SUBMISSION, THE G.C. SHALL MAKE A SITE VISIT TO REVIEW THE DEMOLITIONREQUIREMENTS INCLUDING, BUT NOT LIMITED TO SITE WORK, EXTERIOR & INTERIOR OF THE EXISTINGSTRUCTURE. REVIEW M.E.P. DRAWINGS FOR DEMOLITION REQUIREMENTS / UTILITY RELOCATIONS.COORDINATE ALL DEMOLITION WITH WENDY'S REPRESENTATIVE.17.REMOVE EXISTING FLOOR & WALL FINISHES AS NOTED AND AS REQUIRED FOR NEW FINISHES. CLEAN,PREP, AND REPAIR ALL SUBSTRATES TO SPECIFICATION REQUIREMENTS OF NEW SCHEDULE FINISHES.18.DISCONNECT AND/OR REMOVE ALL UNUSED/ABANDONED ELECTRICAL CIRCUITS FROM ELECTRICALSOURCE PER CODE.19.WHENEVER PRACTICAL TO DO SO AND/OR AS DIRECTED BY WENDY'S REPRESENTATIVE ALL UNUSEDUTILITIES SHALL BE REMOVED IN THEIR ENTIRETY.20.REMOVE (E) FINISHES AND TRIM THROUGHOUT DINING ROOM, HALL, VESTIBULE, & RESTROOMS ASREQUIRED FOR NEW WORK. EXISTING GYPSUM BOARD TO REMAIN IS POSSIBLE EXCEPT WHERESPECIFICALLY NOTED OTHERWISE.21.G.C. TO PHOTOGRAPH AND DOCUMENT THE LOCATION OF ALL KITCHEN AND SERVICE AREAEQUIPMENT PRIOR TO THE START OF CONSTRUCTION.RESTROOM NOTES1.DISCONNECT & REMOVE EXISTING PLUMBING FIXTURES INCLUDING BUT NOT LIMITED TO WATERCLOSETS, URINALS, AND LAVATORIES AS REQUIRED FOR NEW WORK.2.REMOVE EXISTING RESTROOM ACCESSORIES.3.REMOVE EXISTING FLOOR & WALL FINISHES THROUGHOUT THE RESTROOMS. REPLACE SUBSTRATES,DO NOT ADD LAYERS OF SUBSTRATES, ADA CLEARANCES MAY BE VIOLATED WITH THE ADDITION OF (N)LAYERS OF MATERIAL.4.REMOVE & REPLACE DAMAGED SUBSTRATES AS REQUIRED AND IN ACCORDANCE WITH REQUIREMENTSOF NEW SCHEDULED FINISHES. NOTIFY PROJECT ARCHITECT & WENDY'S REPRESENTATIVE OF ANYHAZARDOUS MATERIALS ENCOUNTERED DURING DEMOLITION THAT MAY NEED TESTING ORREMEDIATION.(E) FLOORTILE TOBE REMOVED(E) CARPETTO BEREMOVEDD3.101D3.102D3.103D3.104NREFTRUE(E) FLOORTILE TO BEREMOVEDSERVINGAREA104VESTIBULE100AMEN'SRESTROOM103WOMEN'SRESTROOM102OFFICE111FREEZER108COOLER107KITCHENAREA105DRYSTORAGE110PREPAREA109DRIVETHRU106DININGROOM101VESTIBULE100BCORRIDOR101A(E) PS(R) PS & A.V.(R) PS & A.V.(E) A.V.(E) STRUCTURAL COLUMN TOREMAIN- FINISHES ANDSUBSTRATE ARE TO BE REMOVED(E) WALLS & PIERS TOREMAIN(E) WALLS & PIERS TOREMAIN(R) A.V.(R) A.V.REMOVE (E) DOOR,FRAME ANDHARDWAREREMOVE (E) MOBILEORDER PICKUP SHELF& STORE FORRE-INSTALLATIONREMOVE (E) CONDIMENTSTAND & EQUIPMENT &STORE RE-INSTALLATIONREMOVE (E) FREESTYLEMACHINE, ICE MAKER, & CHASE- STORE FOR RE-INSTALLATIONREMOVE (E) POS& BAKERY CASESTORE FORRE-INSTALLATIONREMOVE (E)HEADER & WALLABOVE TO ACCOMMODATE (N)OPENINGREMOVE (E)HEADER & WALLABOVE TO ACCOMMODATE (N)OPENINGREMOVE (E) TRASHRECEPTACLE STOREFOR RE-INSTALLATIONREMOVE (E) TRASHRECEPTACLE STOREFOR RE-INSTALLATIONREMOVE (E) DRINKSTAND & STORERE-INSTALLATIONB.O.H. SCOPE-N.I.C(E) ARTWORK AND SIGNAGETO BE REMOVED THROUGHOUTDINING ROOM, VESTIBULE, &CORRIDORALL DINING ROOM AND CORRIDORWALL FINISHES SHALL BE REMOVEDU.N.O. - TILE BASE TO BEREMOVED (SEE PARTIAL ELEVATIONON THIS SHEET)REMOVE (E) FLOOR FINISHES. PATCHAND REPAIR SLAB AS REQUIRED FOR(N) FINISHES(E) FURNITURE AND FIXTURES TO BEREMOVED THROUGHOUT DININGROOM & EMPLOYEE AREA - OWNER ISTO DETERMINE WHAT IS TO BE TURNEDOVER OR DISCARDEDREMOVE (E) MENUBOARD & TOASTER -STORE FORRE-INSTALLATIONSEE RESTROOM NOTES ONTHIS SHEET FOR DEMOSCOPEREMOVE (E) HIGHCHAIRSREMOVE (E) SOLARIUM ANDFOUNDATION TO BELOWGRADEREMOVE (E) RUNNERSCREEN & STORE FORRE-INSTALLATIONAPPROXIMATE AREA OFCONCRETE SLAB TO BEREMOVEDREMOVE (E) SOLARIUM SOFFIT(E) WINDOW SILLS TO BEREMOVED - TYP.TRANSITIONROOM105A(E) WINDOW SILLS TO BEREMOVED - TYP.(E) FLOORTILE TO BEREMOVEDREMOVE (E)EQUIPMENT ONSTANDREMOVE (E) COUNTERTOP & FRONTREMOVE (E) ARTPACK &QUEUE BOARDS & STOREFOR REINSTALLATIONREMOVE (E) ARTPACK &STORE FOR REINSTALLATIONREMOVE (E) ARTPACK &STORE FOR REINSTALLATIONREMOVE (E) ARTPACKSTORE FOR REINSTALLATION SITE NUMBER:BASE MODEL:OWNER:BASE VERSION:DESIGN BULLETINS:PROJECT YEAR:ASSET TYPE:CLASSIFICATION:UPGRADE CLASSIFICATION:FURNITURE PACKAGE:042334058FRANCHISEREFRESH-LITECKA2023 JANSTANDARD BASE202420232023 SEALDESCRIPTIONDATEREV.DRAWN BYCHECKED BYSHEET NAMESHEET NUMBER4/3/2024, 9:41 AM, P:\2023\23395 - CKA - Wendy's - Saratoga Springs, NY\Sheet Sets\2024-03-14 Permit\D3.1 DEMOLITION ELEVATIONS.dwg, chavez NOTICE: THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION. IT SHALL NOT BEUSED OR REPRODUCED OR ITS CONTENTSDISCLOSED , IN WHOLE OR IN PART WITHOUTTHE PRIOR WRITTEN CONSENT OF WALLIN /GOMEZ ARCHITECTS, LTD.THESE DRAWINGS HAVE BEEN PREPARED ATAND / OR UNDER MY SUPERVISION AND TO THEBEST OF MY KNOWLEDGE AND BELIEFCONFORM AND COMPLY WITH THEREQUIREMENTS OF THE DEPARTMENT OFBUILDING AND CODES HAVING JURISDICTION.REGISTERED ARCHITECTSTATE OF 711 South Dearborn Street, Suite 606Chicago, Illinois 60605-1827P: 312-427-4702 n F: 312-427-6611E: ADMIN@WGALTD.COM1234567PLOT DATE: 4.3.2024PROJECT NUMBER: 23395DONALD J. WALLINEXPIRATION DATE: AUGUST 31, 2026NEW YORKVCDJW03294604233 24 CONGRESS ST. SARATOGA SPRINGS, NY 12866D3.1DEMOLITIONELEVATIONS1/30/244/3/24-----ISSUED FOR PERMIT-----DESIGN SETEXISTING SIGNAGECALCULATIONSNORTHTOTAL31.5 SF31.5 SF01WEST ELEVATIONSCALE: 1/4" = 1'-0"02EAST ELEVATIONSCALE: 1/4" = 1'-0"03NORTH ELEVATIONSCALE: 1/4" = 1'-0"04SOUTH ELEVATIONSCALE: 1/4" = 1'-0"T.O. CAP+15'-1"T.O. SLAB+0'-0"T.O. CAP+15'-1"T.O. SLAB+0'-0"T.O. CAP+15'-1"T.O. SLAB+0'-0"T.O. CAP+15'-1"T.O. SLAB+0'-0"REMOVE (E)CORNICE, FASCIA& TRUSS BACK TOCMU WALLREMOVE (E)CORNICE, FASCIA& TRUSS BACK TOCMU WALLREMOVE (E)SOLARIUMREMOVE (E)SOLARIUMREMOVE (E) SIGNAGEREMOVE (E)CORNICE, FASCIA& TRUSS BACK TOCMU WALLREMOVE (E)SOLARIUMREMOVE (E) LIGHTSCONCESREMOVE (E) LIGHTSCONCESREMOVE (E) LIGHTSCONCESREMOVE (E) LIGHTSCONCEREMOVE (E) LIGHTSCONCESREMOVE (E) CORNICE & FASCIA(E) FRAMING & SHEATING TOREMAINREMOVE (E) CORNICE & FASCIA(E) FRAMING & SHEATING TOREMAINREMOVE (E) HEADER &WALL TO ACCOMMODATE(N) OPENING SITE NUMBER:BASE MODEL:OWNER:BASE VERSION:DESIGN BULLETINS:PROJECT YEAR:ASSET TYPE:CLASSIFICATION:UPGRADE CLASSIFICATION:FURNITURE PACKAGE:042334058FRANCHISEREFRESH-LITECKA2023 JANSTANDARD BASE202420232023 SEALDESCRIPTIONDATEREV.DRAWN BYCHECKED BYSHEET NAMESHEET NUMBER4/3/2024, 9:41 AM, P:\2023\23395 - CKA - Wendy's - Saratoga Springs, NY\Sheet Sets\2024-03-14 Permit\A1.1 FLOOR PLAN.dwg, chavez NOTICE: THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION. IT SHALL NOT BEUSED OR REPRODUCED OR ITS CONTENTSDISCLOSED , IN WHOLE OR IN PART WITHOUTTHE PRIOR WRITTEN CONSENT OF WALLIN /GOMEZ ARCHITECTS, LTD.THESE DRAWINGS HAVE BEEN PREPARED ATAND / OR UNDER MY SUPERVISION AND TO THEBEST OF MY KNOWLEDGE AND BELIEFCONFORM AND COMPLY WITH THEREQUIREMENTS OF THE DEPARTMENT OFBUILDING AND CODES HAVING JURISDICTION.REGISTERED ARCHITECTSTATE OF 711 South Dearborn Street, Suite 606Chicago, Illinois 60605-1827P: 312-427-4702 n F: 312-427-6611E: ADMIN@WGALTD.COM1234567PLOT DATE: 4.3.2024PROJECT NUMBER: 23395DONALD J. WALLINEXPIRATION DATE: AUGUST 31, 2026NEW YORKVCDJW03294604233 24 CONGRESS ST. SARATOGA SPRINGS, NY 12866A1.1FLOOR PLAN1/30/244/3/24-----ISSUED FOR PERMIT-----DESIGN SETN01FLOOR PLANSCALE: 1/4" = 1'-0"A7.201A2.104A2.103A2.101A2.102REFTRUE(N) FLOORTILE (FT-3)(E) TILE TOREMAIN(E) PULL STATION(R) PULL STATION & A.V. DEVICE(R) PULL STATION & A.V. DEVICEA7.101A7.102A7.103A7.104SERVINGAREA104MEN'SRESTROOM103WOMEN'SRESTROOM102OFFICE111FREEZER108KITCHENAREA105DRYSTORAGE110PREPAREA109DRIVETHRU106COOLER107DININGROOM101(N) FLOORTILE (FT-3)VESTIBULE100AVESTIBULE100BCORRIDOR101AA7.105N(E) A.V. DEVICE(R) A.V.(R) A.V.3'-0"3'-0" +/- 12'-11"+/- 12'-11"R.O 8"SEE A7.2B-5FT-3 P-10SEE A7.2B-5FT-3 P-10CT-2/4SEE A7.1B-5FT-3CT-2SEE A7.1B-5FT-3CT-2EXISTREMAINREMAINCT-4EXISTREMAINREMAINCONTINUE FLOOR TILEUNDER FIXTURES,CASEWORK, & EQUIPMENTCT-2EXISTREMAINREMAINB.O.H. SCOPE-N.I.CTRANSITIONROOM105AFLOOR AND FINISH PLAN GENERAL NOTES1.G.C. TO BE RESPONSIBLE FOR VERIFYING "AS-BUILT" CONDITIONS AND LAYING OUT WORK BEFORE PROCEEDING WITH WORK.2.EXTERIOR FINISHES ARE NOTED ON EXTERIOR ELEVATIONS.3.SEE INTERIOR ELEVATIONS FOR EXTENT OF NEW INTERIOR WALL FINISHES.4.KITCHEN EQUIPMENT SUPPLIER WILL SUPPLY CRITICAL DIMENSIONS, PLUMBING, AND ELECTRICAL SPECIFICATIONS FOR EQUIPMENTSUPPLIED BY THE KITCHEN EQUIPMENT SUPPLIER.5.ELECTRICAL AND PLUMBING CONTRACTOR TO MAKE FINAL CONNECTION TO EQUIPMENT.6.DESIGN INTENT IS FOR EXISTING FINISHES TO BE REPLACED WITH EQUIVALENT NEW FINISHES U.N.O. COORDINATE WITH OWNER FOROPTIONAL FINISH UPGRADES.7.G.C. TO PROVIDE AND INSTALL CRACK ISOLATION/WATERPROOF MEMBRANE AT ALL AREAS OF PORCELAIN, CERAMIC, AND MARBLETILES. 'HYDRO BAN' BY LATICRETE. PROVIDE 'LATASIC' SEALANT @ ALL AREAS OF EXPANSION JOINTS IN SUBSTRATE PRIOR TOINSTALLATION OF 'HYDRO BAN.' CONTACT LATICRETE AT (203)376.81138.PAINTER SHALL BE RESPONSIBLE FOR THE REMOVAL OF HARDWARE, SWITCH AND OUTLET COVERS, ETC., AND REINSTALLATION OFSAME AFTER PAINTING.9.RETOUCH OR REFINISH SURFACES DAMAGED BY SUBSEQUENT WORK AS DIRECTED BY GENERAL CONTRACTOR. THE COST OF SUCHRESTORATION WORK HALL BE BORNE BY THE CONTRACTOR.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING PROPER PROTECTION AGAINST DAMAGE TO EXISTING FURNITURE, ADJACENTFINISHED WORK, FLOORING, ETC. IF APPLICABLE.11.REFER TO REFLECTED CEILING PLAN FOR CEILING TYPES, HEIGHTS, AND FINISHES.12.COORDINATE MUSIC AND WIFI SYSTEM REQUIREMENTS WITH WENDY'S REPRESENTATIVE.13.FOR NEW DRINK STATIONS BEING ADDED, NEW CONDENSERS ON ROOF ARE REQUIRED.CONDENSERS TO BE INSTALLED ONEQUIPMENT RAILS SUPPLIED WITH UNITS. G.C. TO INSTALL EQUIPMENT RAILS AND CONDENSERS NO CLOSER THAN 10'-0" FROM ANYROOF EDGE AND OUTSIDE AIR INTAKE. INSTALL RAILS PARALLEL WITH ROOD SLOPE TO ENSURE POSITIVE DRAINAGE. G.C. TO INSTALLNEW PIPE CURB FOR CONDENSER LINES PER DETAIL 02/A1.1. COORDINATE FINAL LOCATION OF CONDENSERS AND PIPE CURB WITHWENDY'S CONSTRUCTION MANAGER AND A.H.J. PATCH AND REPAIR EXISTING ROOF MEMBRANE AS REQUIRED USING MEMBRANEMANUFACTURER'S STANDARD DETAILS TO ENSURE EXISTING WARRANTY IS MAINTAINED.14.VERIFY LOCATION(S) OF EXISTING FLOOR DRAIN TO SERVE DRINK STAND. PROVIDE NEW DRAIN TO SERVE DRINK STAND WHEREEXISTING IS NOT AVAILABLE. SAW CUT FLOOR SLAB AS REQUIRED FOR INSTALLATION OF NEW DRAIN AND PATCH TO MATCHADJACENT AFTER INSTALLATION. COORDINATE EXACT LOCATION.15.PROVIDE (N) 12" DUROCK SUBSTRATE WHERE FINISH IS TO BE CERAMIC OR PORCELAIN TILE. WHERE REPLACEMENT IS REQUIRED,PROVIDE (N) 12" MOLD RESISTANT DRYWALL WHERE FINISH IS TO BE PAINT.SYMBOL LEGEND##-###-###-###-#WALL FINISHES, SEE FINISH SCHEDULEBASE FINISHES, SEE FINISH SCHEDULECEILING FINISHES, SEE FINISH SCHEDULEFLOOR FINISHES, SEE FINISH SCHEDULEFLOORING TRANSITION:WHERE DIMENSION IS PROVIDED IS WITHIN 2" OF EXISTING,TRANSITION SHALL BE LOCATED AT EXISTING3 EQUAL SPACES3 EQUAL SPACES A3.101V.I.F R.O V.I.F (E) COLUMN(N) LINTEL2∠ 4 X 3 12 X 516(N) LINTEL2∠ 4 X 3 12 X 516 RSITE NUMBER:BASE MODEL:OWNER:BASE VERSION:DESIGN BULLETINS:PROJECT YEAR:ASSET TYPE:CLASSIFICATION:UPGRADE CLASSIFICATION:FURNITURE PACKAGE:042334058FRANCHISEREFRESH-LITECKA2023 JANSTANDARD BASE202420232023 SEALDESCRIPTIONDATEREV.DRAWN BYCHECKED BYSHEET NAMESHEET NUMBER4/3/2024, 9:40 AM, P:\2023\23395 - CKA - Wendy's - Saratoga Springs, NY\Sheet Sets\2024-03-14 Permit\A2.1 EXTERIOR ELEVATIONS.dwg, chavez NOTICE: THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION. IT SHALL NOT BEUSED OR REPRODUCED OR ITS CONTENTSDISCLOSED , IN WHOLE OR IN PART WITHOUTTHE PRIOR WRITTEN CONSENT OF WALLIN /GOMEZ ARCHITECTS, LTD.THESE DRAWINGS HAVE BEEN PREPARED ATAND / OR UNDER MY SUPERVISION AND TO THEBEST OF MY KNOWLEDGE AND BELIEFCONFORM AND COMPLY WITH THEREQUIREMENTS OF THE DEPARTMENT OFBUILDING AND CODES HAVING JURISDICTION.REGISTERED ARCHITECTSTATE OF 711 South Dearborn Street, Suite 606Chicago, Illinois 60605-1827P: 312-427-4702 n F: 312-427-6611E: ADMIN@WGALTD.COM1234567PLOT DATE: 4.3.2024PROJECT NUMBER: 23395DONALD J. WALLINEXPIRATION DATE: AUGUST 31, 2026NEW YORKVCDJW03294604233 24 CONGRESS ST. SARATOGA SPRINGS, NY 12866A2.1EXTERIORELEVATIONS1/30/244/3/24-----ISSUED FOR PERMIT-----DESIGN SETPROPOSED SIGNAGECALCULATIONSNORTHTOTAL32.5 SF32.5 SFLEGENDNOTE: REFER TO MATERIAL /FINISH / RESPONSIBILITYSCHEDULE ON SHEET A6.1 FORSPECIFICATIONS OF ALL EXTERIORMATERIALS AND FINISHESM-2CORRUGATED METAL PANELDARK BRONZEEXISTING BRICKEVO DOWNLIGHT& ACCENT BANDM-1/PEX-1DARK BRONZET.O. CAP+15'-1"T.O. SLAB+0'-0"01WEST ELEVATIONSCALE: 1/4" = 1'-0"02EAST ELEVATIONSCALE: 1/4" = 1'-0"04SOUTH ELEVATIONSCALE: 1/4" = 1'-0"03NORTH ELEVATIONSCALE: 1/4" = 1'-0"T.O. CAP+15'-1"T.O. SLAB+0'-0"PEX-9/M-4SILVERT.O. CAP+15'-1"T.O. SLAB+0'-0"G-1SF-1G-1SF-1G-1SF-1G-1SF-1G-1SF-1M-2(N) WENDY'S SIGNAGE (WHITE LETTERS) - PROVIDEJ-BOX FOR SIGNAGE AND EXTERIOR LIGHTING.CONNECT TO EXISTING CIRCUITS, TYP.PEX-9(E) ACCENT BANDPEX-9(E) ACCENT BANDPEX-9(E) ACCENTBANDPEX-1(E)FASCIAPEX-1(E) FASCIA3'-0"10'-10"EQ(N) PRE-FINISHED REFRESHEVO DOWNLIGHTING & ACCENTBAND. PROVIDE BLOCKING ASREQ'DEQPEX-9(E) ACCENT BANDPEX-9(E) ACCENT BANDPEX-9(E) ACCENTBANDPEX-1(E) FASCIAPEX-9(E) COPINGPEX-1(E) DOOR & FRAMEPEX-1(E) ELEC. METERPEX-1PEX-9(E) ACCENTBANDPEX-1(E) FASCIAM-2(N) PRE-FINISHED REFRESHEVO DOWNLIGHTING & ACCENTBAND. PROVIDE BLOCKING ASREQ'DPEX-9(E) ACCENT BANDPEX-9(E) COPINGPEX-9(E) ACCENTBANDPEX-1(E) FASCIA(N) PRE-FINISHED REFRESHEVO DOWNLIGHTING & ACCENTBAND. PROVIDE BLOCKING ASREQ'DM-2PEX-9(E) ACCENT BANDPEX-9(E) COPINGPEX-1(E) FASCIAPEX-1(E) FASCIAPEX-1(E) FASCIAPEX-1(E) FASCIAG-1SF-1G-1SF-1G-1SF-1PEX-9(E) ACCENT BAND(E) LIGHT FIXTUREM-1(N) LIGHT FIXTURE (K-10)- TYPM-1(N) LIGHT FIXTURE (K-10)- TYPM-1(N) LIGHT FIXTURE (K-10)- TYPM-1(N) LIGHT FIXTURE (K-10)- TYPM-1(N) LIGHT FIXTURE (K-10)- TYPM-1(N) LIGHT FIXTURE (K-10)- TYPE-1-PAINT (PEX-13)1'-6"6'-7"11"6"4'-7"1'-0"(N) OPAQUE FILMOVER (E) INTERIOR GLASSA3.101E-1EIFS -(PAINT PEX-13)(E) BRICK(E) BRICK(N) METAL TRIMM-1M-1OPP HDA3.201A3.201 SEALDESCRIPTIONDATEREV.DRAWN BYCHECKED BYSHEET NAMESHEET NUMBER4/3/2024, 9:42 AM, P:\2023\23395 - CKA - Wendy's - Saratoga Springs, NY\Sheet Sets\2024-03-14 Permit\A6.1 FINISH SCHEDULES.dwg, chavez NOTICE: THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION. IT SHALL NOT BEUSED OR REPRODUCED OR ITS CONTENTSDISCLOSED , IN WHOLE OR IN PART WITHOUTTHE PRIOR WRITTEN CONSENT OF WALLIN /GOMEZ ARCHITECTS, LTD.THESE DRAWINGS HAVE BEEN PREPARED ATAND / OR UNDER MY SUPERVISION AND TO THEBEST OF MY KNOWLEDGE AND BELIEFCONFORM AND COMPLY WITH THEREQUIREMENTS OF THE DEPARTMENT OFBUILDING AND CODES HAVING JURISDICTION.REGISTERED ARCHITECTSTATE OF 711 South Dearborn Street, Suite 606Chicago, Illinois 60605-1827P: 312-427-4702 n F: 312-427-6611E: ADMIN@WGALTD.COM1234567PLOT DATE: 4.3.2024PROJECT NUMBER: 23395DONALD J. WALLINEXPIRATION DATE: AUGUST 31, 2026NEW YORKVCDJW03294604233 24 CONGRESS ST. SARATOGA SPRINGS, NY 12866A6.1FINISH SCHEDULES1/30/244/3/24-----ISSUED FOR PERMIT-----DESIGN SETSITE NUMBER:BASE MODEL:OWNER:BASE VERSION:DESIGN BULLETINS:PROJECT YEAR:ASSET TYPE:CLASSIFICATION:UPGRADE CLASSIFICATION:FURNITURE PACKAGE:042334058FRANCHISEREFRESH-LITECKA2023 JANSTANDARD BASE202420232023 CEILINGCT-4CEILING TILE (SERVINGAREA; CONDIMENTAREAARMSTRONG VINYLCLAD SQUARE LAY-IN; BP671: 24" x 24" x 1/2"COLOR: WHITEGRID: PRELUDE 15/16"; WHITELAMINATEL-5LAMINATEPIONITE; "MORCHELLA HUNT", LINE Z; WO740-LZ-G49WALL BASEB-5TILE BASE(DINING ROOM,RESTROOM)CROSSVILLE: COLOR BLOX 2.0; "I SEE THE MOON"SIZE: 6" x 12"GROUT: GR-7MOTAR: MR-1WATERPROOFING: WM-1, EXTEND 6" UP & 6" OUT PERIMETER WALLSJOINTS: 1/8"WALLSP-6WHITE(WALLS & TRIM)SHERWIN WILLIAMS: SW 8917 "SHELL WHITE"BENJAMIN MOORE: OC-17 "WHITE DOVE"PPG: PPG 18-09 "GARLIC CLOVE"P-10 BLUESHERWIN WILLIAMS: SW 9138 "STARDEW"BENJAMIN MOORE: AF-545 "SOLITUDE"PPG: PPG 1037-3 "SPECIAL DELIVERY"GYPSUM BOARDSHEEN: EGGSHELLSHERWIN WILLIAMSPRIME: PROMAR 200 ZERO VOC PRIMERFINISH: PROMAR 200 ZERO EGGSHELLBENJAMIN MOOREPRIME: 032 FRESH START ALL PURPOSE PRIMERFINISH: 485 ULTRA SPEC SCUFF-X EGGSHELLPPG-PRIME: PPG SPEEDHIDE 6-2 INTERIOR QD ACRYLIC PRIMERFINISH: PPG-6-411 INTERIOR EGGSHELLGYPSUM BOARD ATRESTROOM & KITCHENSHEEN: SEMI-GLOSSSHERWIN WILLIAMS-PRIME: PROMAR 200 VOC PRIMERFINISH: PROMAR 200 VOC SEMI-GLOSSPPG-PRIME: PPG SPEEDHIDE 6-2 INTERIOR QD ACRYLIC PRIMERFINISH: PPG SPEEDHIDE 6-500 INTERIOR SEMI-GLOSSST0REFR0NT / GLAZINGSF-1STOREFRONT-DARK BRONZEUS ALUMINUM: IT451/451; "DARK BRONZE" ANODIZED ALUMINUMALTERNATE: KAWNEER TRIFAB VG 451T/451; #40 "DARK BRONZE" ANODIZEDALUMINUMEQUALS BY TUBELITE & OLDCASTLEG-11" INSULATED GLASS(TEMPERED WHEREINDICATED)ACM SYSTEMSINTERIOR FINISH SCHEDULEFLOORSFT-3FLOOR TILE(DINING ROOM,RESTROOM)CROSSVILLE: "CEMENTED RELATIONSHIP" SWCR/.12424UPSMATTE FINISHSIZE: 24" x 24"GROUT: GR-7 (GR-10 AT RESTROOM FLOORS)MORTAR: MR-1WATERPROOFING: WM-1; EXTEND 6" UP AND 6" OUT PERIMETER WALLS(RESTROOM AREAS ONLY)JOINTS: 1/8"TRIM: SCHLUTER; QUADEC (SATIN NICKEL ANOD. ALUM.)CT-2CEILING TILE(DINING ROOM)ARMSTRONG ULTIMA 1911: 24" x 24" x 3/4"COLOR: WHITEGRID: PRELUDE 15/16"; WHITEEXTERIOR FINISH SCHEDULESILVER - SATINSHERWIN WILLIAMS: "SILVER BRIGHT" ALUMINUM PAINTBENJAMIN MOORE: P22 78 "SILVER URETHANE ALKYD"PPG: 6-230 "BRIGHT ALUMINUM"PEX-9GR-7GROUTMAPEI; ULTRACOLOR PLUS FA (25 LBS.)COLOR: "GRAY" #09JOINTS: 1/8"GR-10GROUTMAPEI; KERAPOXY IEG CQ (49936 LARGE UNIT CONTAINS 4 PART A & 4 PART BLIQUIDS, SCRUB PAD AND INSTRUCTION SHEET) ALSO NEED (4) 9.29 BAGS OF4XX10 POWDER PURCHASED SEPARATELYCOLOR: "GRAY" #09JOINTS: 1/8"MR-1MORTARPRODUCT: MAPEI; KERAFLEX SUPER (44 LBS.)WM-1WATERPROOFINGMEMBRANEPRODUCT:MAPEI; MAPELASTIC AQUADEFENCE 5 GALLON (01968)WT-3WALL TILE(DINING ROOM,HALLWAY)CROSSVILLE: "WIND WHIPPED" (SWWW/.10508S)SIZE: 4" x 8"PATTERN: SEE INTERIOR ELEVATIONSGROUT: GR-7MOTAR: MR-1JOINTS: 1/8"TRIM: SCHULTER; QUADEC (AE: SATIN ANOD. ALUM.)WT-6WALL TILE(RESTROOM)CROSSVILLE: "FROST CALIBRATED" (AV241.11224UPSC)SIZE: 12" x 24"PATTERN: STACK BONDGROUT: GR-7MOTAR: MR-1JOINTS: 1/8"TRIM (HORIZONTAL): SCHLUTER; SCHEINE (SATIN NICKEL ANOD. ALUM.)TRIM (OUTSIDE CORNER): SCHULTER; QUADEC W/ CORNER INSERTS (SATIN NICKELANOD. ALUM.)WT-9WALL TILE(DINING ROOM,RESTROOM)CROSSVILLE: "CHARRED" (SWSF/.10412UPS)SIZE: 4" x 12"PATTERN: RUNNING BONDGROUT: GR-11MOTAR: MR-1JOINTS: 1/8"TRIM: SCHULTER; QUADEC (DARK BRONZE ANOD. ALUM.)GROUT, MORTAR, WATERPROOFING MEMBRANEGR-11GROUTMAPEI; ULTRACOLOR PLUS FA (25 LBS.)COLOR: "BLACK" #10JOINTS: 1/8"SOLID SURFACESS-4SOLID SURFACECORIAN; CONCRETE; "NEUTRAL CONCRETE" (C1) MISCELLANEOUSIECC CLIMATE ZONES 4-8 (NORTH):OPTION #1 - GUARDIAN GLASS:OUTBOARD LITE: GUARDIAN "SN 68" (#2) ON 1/4" CLEARINBOARD LITE: GUARDIAN 1/4" CLEARSPACE: 1/2" AIROPTION #2 - VITRO (PPG) ARCHITECTURAL GLASSOUTBOARD LITE: VITRO ARCHITECTURAL GLASS"SOLARBAN 60" (#2)ON 1/4" CLEARINBOARD LITE: VITRO ARCHITECTURAL GLASS 1/4" CLEARSPACE: 1/2" AIRMETALSM-1M-4ROOF EDGE/PARAPET CAPEXCEPTIONAL METALS; 24 GA GALVALUME STEELCOLOR: MILL FINISH, "SILVER METALLIC"CORRUGATED METALPANELPRODUCT: ALCOA, REYNOLUX; 7.2" RIB PANEL; 0.032" THICKNESSCOLOR: PRE-FINISHED; COLORWELD 500; "CLASSIC BRONZE" (RB4CW5CB,BN2N104B)M-2BRAKE METAL (FASCIA,TRIM, ETC)NEW PRODUCT: EXCEPTIONAL METALS; 24 GA GALVALUME STEELCOLOR: PRE-FINISHED, "DARK BRONZE"EXTERIOR CLADDING E-1EIFS (EXTERIORINSULATED FINISHSYSTEM)STO, "StoTHERM ESSENCE NExT" SYSTEMTEXTURE: FINE SAND (U.N.O.) SEE SPECIFICATIONS FOR ADDITIONALINFORMATIONCOATING: TOP-COAT WITH 2 COATS OF STO COAT ACRYL PLUS IN SPECIFIEDCOLOR; TWO ADDITIONAL COATS OF STO COAT ACRYYL PLUS CLEAR MATT,IMPACT PROVIISO "ARMOR MAT" REINFORCING MESH UP TO 6'-9" ABOVEGRADE.COLORS:EIFS SYSTEMALTERNATE: DRYVIT, "OUTSULATION PLUS MD SYSTEM"TEXTURE: SANDPEBBLE FINE (U.N.O.)COATING: OUTSULATION PLUS MD SYSTEM, HIGH-IMAPCT "PANZER MESH"REINFORCINGCOLORS: MATCH STO COLORS ABOVEEXTERIOR FINISH SCHEDULEE-1: PAINTED PEX-13INTERIOR PAINT SCHEDULEEXTERIOR MISC.MASONRYINTERIOR PAINTINTERIOR PRIMERBENJAMIN MOOREPRIME: 032 FRESH START ALL PURPOSE PRIMERFINISH: 487 ULTRA SPEC SCUFF-X SEMI-GLOSSEXTERIOR PAINT SCHEDULEEXTERIOR PAINTEXTERIOR PRIMERPEX-1DARK BRONZESHERWIN WILLIAMS: BRONZETONE CUSTOM COLORS: "MISSISSIPPI BRONZE"BENJAMIN MOORE: "BRONZETONE"PPG: 1002-7 "PHANTOM MIST"PEX-10BLACKSHERWIN WILLIAMS: SW 6258 "TRICORN BLACK"BENJAMIN MOORE: HC-19 "BLACK"PPG: PPG 1001-7 "BLACK MAGIC"PEX-13LIGHT TANSHERWIN WILLIAMS: SW 6106 "KILIM BEIGE"BENJAMIN MOORE: 1128 "ABODE BEIGE"PPG: PPG 14-17 "ARMADILLO"STUCCO / EIFSSHEEN: SATINSHERWIN WILLIAMSPRIME: LOXON CONCRETE & MASONRY PRIMERFINISH: A-100 EXTERIOR LATEX SATINBENJAMIN MOOREPRIME: 023 FRESH START ALL PURPOSE PRIMERFINISH: 631 AURA WATERBORNE EXTERIOR SATINPPG-PRIME:PPG SEAL GRIP 17-92 XI ACRYLIC UNIVERSAL PRIMERFINISH: PPG SPEEDHIDE 6-2045XI EXTERIOR SATIN ACRYLICMETAL RAILINGSHEEN: SEMI-GLOSSSHERWIN WILLIAMSPRIME: PROCRYL UNIVERSAL METAL PRIMERFINISH: SHER-CRYL HPA (SEMI-GLOSS)BENJAMIN MOOREPRIME: HP04 METAL PRIMER; ALTERNATE: SELF PRIME HP29FINISH: HP29 DTM ACRYLIC SEMI-GLOSS ENAMELPPGPRIME: PPG PITT-TECH PLUS 4020PF DTM ACRYLIC METAL PRIMERFINISH: SPEEDHIDE EXTERIOR 6-900XI 100% ACRYLIC LATEX SEMI-GLOSSPLASTIC (HERITAGE II)SHEEN: SATINSHERWIN WILLIAMSPRIME: EXTREME BOND PRIMERFINISH: SHER-CRYL HPA (SEMI-GLOSS)PPGPRIME: PPG SEAL GRIP 17-921XI ACRYLIC UNIVERSAL PRIMERFINISH: PPG SPEEDHIDE 6-2045XI EXTERIOR SATIN ACRYLICBENJAMIN MOOREPRIME: 023 FRESH START ALL PURPOSE PRIMERFINISH: 631 AURA WATERBORNE EXTERIOR SATINMETALSHEEN: SATINRECOMMENDED TO USE PPGBENJAMIN MOOREPRIME: HP04 ACRYLIC METAL PRIMER; ALTERNATE: SELF PRIME P23-60FINISH: P23-60 DTM ALKYD LOW LUSTER ENAMELPPG (RECOMMENDED)PRIME: PPG PITT-TECH PLUS 4020PF DTM ACRYLIC METAL PRIMERFINISH: PPG PITT-TECH PLUS 4216HD SEMI-GLOSS DTM ACRYLICMETALSHEEN: SATINEXTERIOR PRIMER FOR PEX-9SHERWIN WILLIAMSPRIME: PROCRYL UNIVERSAL METAL PRIMERFINISH: SILVER BRITE ALUMINUM PAINT (2 COATS) #B59S11BENJAMIN MOOREPRIME: HP04 ALKYD METAL PRIMERFINISH: HP25 DTM ACRYLIC LOW LUSTER ENAMELPPGPRIME: PPG PITT-TECH PLUS 4020PF ACRYLIC METAL PRIMERFINISH: SPEEDHIDE EXTERIOR 90-474 DTM SATIN ACRYLIC ENAMEL FRONT FACADE - SIGNAGE/FASCIA REPLACEMENT - FRONT SOLARIUM DEMOLITION SIDE FACADE - FASCIA REPLACEMENT/PAINTING - WALL SCONCE REPLACEMENT REAR FACADE - FASCIA AND COPING PAINTING SIDE FACADE - FASCIA REPLACEMENT AND PAINTING - FRONT SOLARIUM DEMOLITION SIDE FACADE - FASCIA REPLACEMENT/PAINTING - WALL SCONCE REPLACEMENT PYLON SIGN - RE-FACING OF EXISTING SIGNAGE PROJECTING HANGING GROUND EXTERNAL ILLUM. NON-ILLUM. DOUBLE FACE X XX/XX/XX SIGN TYPE SPECIFICATIONS SCALE: U1201-IA-36NR-WHT-RC 3/8”=1’REV# REV.DATE:DGNR:SALES:RTK T. SHEEHY LANDLORD:CUSTOMER: DATE:DATE: Approval Signatures Required to insure that all spelling, colors, and specifications for sign(s) rendered meets customer & landlord approvals. FACE TRIMS PROVIDED FASCIA COLOR REQUIRED RADIUS DIM. BUILDING DIM. FACADE ANGLE OTHER If required, customer to provide Custom Sign Center, Inc. with camera ready or appropriate digital file. Please contact your salesperson or Design Staff for appropriate file types. ARTWORKSIGN SURVEY ILLUMINATED SINGLE FACE U1201-IA-36NR-WHT-RC 1/1/13 FILENAME: DATE: WALL 10'-10 3/16" 4 3/16" - .040” ALUMINUM SIDES AND BACKS PAINTED 313 DARK BRONZE - “WENDY’S” - EMBOSSED #7328 WHITE POLYCARBONATE FACES WITH WHITE L.E.D. ILLUMINATION - CAMEO - FORMED POLYCARBONATE FACE WITH PRINTED GRAPHICS SECOND SURFACE WITH WHITE LED ILLUMINATION. 32.5 SqFt TOTAL COLORS 313 DARK BRONZE PMS 201 BURGUNDY HAIR PMS 299 BLUE PMS 439 BROWN PMS 698 PINK PMS 186 RED HAIR 7'-3"39" 36" Columbus, OH 43204 FX: 614-279-7525 ALL WIRING MEETS NEC 2014 SPECIFICATIONS. SIGN TO BE WIRED TO A STANDARD 120 VOLT / 20 AMP CIRCUIT. THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. WHITE 21.75 SqFt 9.75 SqFt E122574 DISCONNECT SWITCH 5" SECTION/MOUNTING DETAILS 2"X4" STEEL STUDS 16" O/C 1/2" CDX PLYWOOD STUCCO 12 VOLT ELECTRONIC POWER SUPPLY MOUNTED WITHIN WIRING BOX LETTERS AND CAMEO MOUNT WITH 1/4" X 3" HEX HEAD DRIVE SCREWS (3 CONNECTIONS PER LETTER MINIMUM) FORMED POLYCARBONATE FACES AND RETURNS WIRING COMPARTMENT EXISTING OR BY OWNER .040" ALUMINUM SIDES AND BACKS 12 GAUGE,120 VOLT PRIMARY WIRING WITHIN STEEL CONDUIT. (QTY 1) DEDICATED 20 AMP CIRCUIT BY OWNER WHITE L.E.D. ILLUMINATION (QTY. 38) PERMLIGHT L.E.D.'S PART# PFS 8510W65 GROUNDING AND BONDING OF SIGN CABINET COMcheck Software Version 4.1.5.3 Interior Lighting Compliance Certificate Project Title: 2018 IECC Project Type:Alteration Construction Site: 24 Congress St Saratoga Springs, NY Owner/Agent:Designer/Contractor: Wallin/Gomez Architects, Ltd. 711 S Dearborn Suite 606 Chicago, IL 60605 312-427-4702 admin@wgaltd.com Project Information Energy Code: Wendy's Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Common Space Types:Dining Area - Family Restaurant 812 0.71 577 2-Common Space Types:Restrooms 146 0.85 124 3-Serving Area (Common Space Types:Food Preparation)104 1.06 110 811Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Common Space Types:Dining Area - Family Restaurant (812 sq.ft.) A-1: LED PAR 11W:1 20 11 220 A-2: LED PAR 10W:1 5 10 50 P-4L: Other:1 2 18 36 Common Space Types:Restrooms (146 sq.ft.) A-1: LED PAR 11W:1 7 11 77 Serving Area ( Common Space Types:Food Preparation 104 sq.ft.) A-1: LED PAR 11W:1 6 11 66 449Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: Wendy's P:\2023\23395 - CKA - Wendy's - Saratoga Springs, NY\Project Administration\Permit\BUILDING DEPT\2024-04-09 Submittal\2024-04-09 Comcheck.cck 04/09/24Report date: 61 ofPage Donald Wallin - Architect 04-09-24 Inspection Checklist Requirements: 0.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.5.3 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2018 IECC Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wendy's P:\2023\23395 - CKA - Wendy's - Saratoga Springs, NY\Project Administration\Permit\BUILDING DEPT\2024-04-09 Submittal\2024-04-09 Comcheck.cck 04/09/24Report date: 62 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.2. 2 [EL22]1 Spaces required to have light- reduction controls have a manual control that allows the occupant to reduce the connected lighting load in a reasonably uniform illumination pattern >= 50 percent. Complies Does Not Not Observable Not Applicable C405.2.1, C405.2.1. 1 [EL18]1 Occupancy sensors installed in classrooms/lecture/training rooms, conference/meeting/multipurpose rooms, copy/print rooms, lounges/breakrooms, enclosed offices, open plan office areas, restrooms, storage rooms, locker rooms, warehouse storage areas, and other spaces <= 300 sqft that are enclosed by floor-to-ceiling height partitions. Reference section language C405.2.1.2 for control function in warehouses and section C405.2.1.3 for open plan office spaces. Complies Does Not Not Observable Not Applicable C405.2.1. 2 [EL19]1 Occupancy sensors control function in warehouses: In warehouses, the lighting in aisleways and open areas is controlled with occupant sensors that automatically reduce lighting power by 50% or more when the areas are unoccupied. The occupant sensors control lighting in each aisleway independently and do not control lighting beyond the aisleway being controlled by the sensor. Complies Does Not Not Observable Not Applicable C405.2.1. 3 [EL20]1 Occupant sensor control function in open plan office areas: Occupant sensor controls in open office spaces >= 300 sq.ft. have controls 1) configured so that general lighting can be controlled separately in control zones with floor areas <= 600 sq.ft. within the space, 2) automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space, 3) are configured so that general lighting power in each control zone is reduced by >= 80% of the full zone general lighting power within 20 minutes of all occupants leaving that control zone, and 4) are configured such that any daylight responsive control will activate space general lighting or control zone general lighting only when occupancy for the same area is detected. Complies Does Not Not Observable Not Applicable C405.2.2, C405.2.2. 1, C405.2.2. 2 [EL21]2 Each area not served by occupancy sensors (per C405.2.1) have time- switch controls and functions detailed in sections C405.2.2.1 and C405.2.2.2. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wendy's P:\2023\23395 - CKA - Wendy's - Saratoga Springs, NY\Project Administration\Permit\BUILDING DEPT\2024-04-09 Submittal\2024-04-09 Comcheck.cck 04/09/24Report date: 63 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.3, C405.2.3. 1, C405.2.3. 2 [EL23]2 Daylight zones provided with individual controls that control the lights independent of general area lighting. See code section C405.2.3 Daylight-responsive controls for applicable spaces, C405.2.3.1 Daylight responsive control function and section C405.2.3.2 Sidelit zone. Complies Does Not Not Observable Not Applicable C405.2.4 [EL26]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable C405.2.4 [EL27]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable C405.3 [EL6]1 Exit signs do not exceed 5 watts per face. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wendy's P:\2023\23395 - CKA - Wendy's - Saratoga Springs, NY\Project Administration\Permit\BUILDING DEPT\2024-04-09 Submittal\2024-04-09 Comcheck.cck 04/09/24Report date: 64 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C303.3, C408.2.5. 2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable C405.4.1 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. C408.2.5. 1 [FI16]3 Furnished as-built drawings for electric power systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable C408.3 [FI33]1 Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wendy's P:\2023\23395 - CKA - Wendy's - Saratoga Springs, NY\Project Administration\Permit\BUILDING DEPT\2024-04-09 Submittal\2024-04-09 Comcheck.cck 04/09/24Report date: 65 ofPage Project Title: Data filename: Wendy's P:\2023\23395 - CKA - Wendy's - Saratoga Springs, NY\Project Administration\Permit\BUILDING DEPT\2024-04-09 Submittal\2024-04-09 Comcheck.cck 04/09/24Report date: 66 ofPage PROJECTING HANGING GROUND COLOR EXTERNAL ILLUM. NON-ILLUM. DOUBLE FACE X XX/XX/XX SIGN TYPE SPECIFICATIONS SCALE: AS NOTEDREV# REV.DATE:DGNR:SALES:THW T. SHEEHY LANDLORD:CUSTOMER: DATE:DATE: Approval Signatures Required to insure that all spelling, colors, and specifications for sign(s) rendered meets customer & landlord approvals. COLORS Columbus, OH 43204 FACE TRIMS PROVIDED FASCIA COLOR REQUIRED RADIUS DIM. BUILDING DIM. FACADE ANGLE OTHER If required, customer to provide Custom Sign Center, Inc. with camera ready or appropriate digital file. Please contact your salesperson or Design Staff for appropriate file types. ARTWORKSIGN SURVEY ILLUMINATED SINGLE FACE - .090 ALUMINUM CONTINUOUS RAIL WELDED TO 24 GAUGE SHEET METAL w/PAINT GRIP. - ALL SURFACES PAINTED GG BRUSHED ALUMINUM - WHITE AgiLight SignRayz Pro 160 LED ILLUMINATION 2/8/16 FILENAME: DATE: CANOPY GG BRUSHED ALUMINUM FRONT VIEW - DOWNLIGHT BRACKET/LED FIXTURE SCALE: 1/2" = 1'-0" 10.48 SqFt EVOLUTION DOWNLIGHTING 2-8-16 REFRESH EVOLUTION DOWN LIGHTING \\lesvr\Design\1 WENDYS\WENDYS PRODUCT CATALOGS\2015 CATALOG\2015 CATALOG\All Signage\Refresh Evolution\EVOLUTION DOWNLIGHTING RACEWAY.cdr THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. ALL WIRING MEETS NEC 2014 SPECIFICATIONS. SIGN TO BE WIRED TO A STANDARD 120 VOLT / 20 AMP CIRCUIT. E1225741’-0”SIDE VIEW - MOUNTING DETAIL SCALE: 1 1/2" = 1'-0" AgiLight SignRayz Pro160 LED LS-PRO160-30K-2B1 PRODUCT RATINGS 0’-7 1/2”1’-0”0’-5 1/2”0’-3 1/2”EXISTING MEMBRANE ROOFING HEAT WELD NEW MEMBRANE INTO EXISTING ROOF MEMBRANE MEMBRANE TO WRAP OVER PARAPET WALL LIGHT BAND RACEWAY LED MODULE .090” DECORATIVE ALUMINUM TRIM PANEL PRE-FINISHED FLASHING LIGHT LOCK PANEL Specifications Part number ..................................5000 K ......................701956-5WL461 3500 K ......................701956-3WL461 Dimensions L × W × H .................1168 mm × 23 mm × 9 mm (46 in × 0.89 in × 0.35 in) Lumens per fixture ......................5000 K ......................970 3500 K ......................825 In-field bends ................................Radial bend..............305 mm (12 in) Color temperatures (nominal) ..5000 K, 3500 K Color rendering index (CRI) ........5000 K ......................70 (nominal) 3500 K ......................82 (nominal) Estimated product lifetime .......50,000 hours (L70) Operating temperature ..............-40° C to 70° C Protection class ............................IP66 & IP68* Special feature..............................Cuttable every 150 mm (6 in) for two usable sides Power ..............................................7.4 W per meter (2.25 W per foot), 9.0 W per fixture Efficacy ...........................................5000 K ......................108 lm/W 3500 K ......................92 lm/W Fastening .......................................Peel-n-stick or mounting clips (401203), 4 included with each unit Power capacity .............................6 units per SloanLED 60 W 12 VDC power supply 5000 K only 5000 K only * IP66 & IP68 ratings provide protection for extreme outdoor and wet applications or harsh weather exposure. Do not mount in a submerged application. Accessories Mounting Clip 401203 Four (4) included with each unit. Sold in bags of 20. † Configured for Class 2 Output. Power Supply Capacity 12 VDC Power supply† Power output SlimLINER Fixtures 20 W 20 W 2 25 W 25 W 2 60 W 60 W 6 120D1 120 W [701507-120D1]120 W 6 × 2 Power used per meter/foot in Watts 7.4 W / 2.25 W per fixture SlimLINER Low-profile outdoor and indoor linear lighting © 2021 SloanLED Rev C 2021-01-28 SloanLED.com Specifications subject to change without notice. SloanLED Headquarters 5725 Olivas Park Drive, Ventura, CA, USA 805.676.3200 • info@SloanLED.com SloanLED Europe b.v. Argonstraat 110, 2718 SN Zoetermeer, NL +31 88 12 44 900 • europe@SloanLED.com Project: Type: Ordering # : Comments: 33 Donald Drive Fairfield, OH 45014 ph:(513)858-6004 fax:(513)858-6038 email:sales@teronlight.com web:teronlight.com FEATURES ARCHITECTURAL OUTDOOR MASTERS LED-WENDYS CUSTOM Clear Polycarbonate Diffuser 34065 • Steel Trim Bands w/ Textured Bronze Powder Coat Finish • Standard Up / Down Light Output Internal Fixture: • Die-Cast Aluminum Ballast Housing w/ Textured Black Powder Coat Finish • Clear Polycarbonate Diffuser • Mounts Direct to Flat Surface w /Four #8 Wall Anchors (Not Included) • Thermal Compensation Technology Ensures Longer LED Lifetime, Which is Ideal For Fixtures Being Placed in Area With Fluctuating or Higher Ambient Temperatures • 100V - 277V • One 20W LED Driver • Surge Protector • CSA Listed Wet location For Wall Mounting • Awaiting IES Files, DLC, Lighting Facts, And Title 24 Labeling / Certfication We reserve the right to revise the design or components of any product due to parts availability or change in UL standards, without assuming any obligation or liability to modify any products previously manufactured, and without notice. MS ORDERING INFORMATION Example : (MS - L16.8 - 100 - 277V - BZ - 40K) Textured Bronze is Standard Finish REPLACEMENT PARTS PART NO. NOTES PRODUCT SOURCE/WATTAGE VOLTAGE DIFFUSER FINISH OPTIONS Masters L12.6 - (3) 4.2W LED Strips L16.8 - (4) 4.2W LED Strips 4.2W LED Strips - (LM80 Standard) **40,000 Hours( L70) 100 - 277V Not Applicable BZ - Textured Bronze L12.6 - Three 4.2W LED Modules 40K - 4000K Color Temp. -3 Nichia NS3x183 Series LEDs Per Module -SW30Bin, Color Temp = 3000K Nominal -Voltage Regulated at 12 Volts by Driver -80 CRI typ. (75 CRI min) 754 TOTAL Lumens 17.2W Input = Estimated 32.8 Lumens Per Watt L16.8 - Four 4.2W LED Modules 40K - 4000K Color Temp. -3 Nichia NS3x183 Series LEDs Per Module -SW30Bin, Color Temp = 3000K Nominal -Voltage Regulated at 12 Volts by Driver -80 CRI typ. (75 CRI min) 754 TOTAL Lumens 23W Input = Estimated 32.8 Lumens Per Watt ALL WIRING MEETS NEC 2014 SPECIFICATIONS. SIGN TO BE WIRED TO A STANDARD 120 VOLT / 20 AMP CIRCUIT. THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. MODEL IA-WP36 CAMEOS MOUNT 6" ABOVE TOP OF SIGN CABINET ENTIRE POLE COVER 313 DARK BRONZE SIGN CABINET 313 DARK BRONZE Description Here for Other Items X XX/XX/XX SINGLE FACE PROJECTING HANGING WALL NON-ILLUM. EXTERNAL ILLUM. SIGN TYPE SPECIFICATIONS ILLUMINATED GROUND FILENAME: SCALE: U0601-IA-WP36 3/8”=1’REV# DATE: REV.DATE:DGNR:SALES:THW T. SHEEHY DATE: DATE:CUSTOMER: LANDLORD: Approval Signatures Required to insure that all spelling, colors, and specifications for sign(s) rendered meets customer & landlord approvals. FACE TRIMS PROVIDED FASCIA COLOR REQUIRED RADIUS DIM. BUILDING DIM. FACADE ANGLE OTHER If required, customer to provide Custom Sign Center, Inc. with camera ready or appropriate digital file. Please contact your salesperson or Design Staff for appropriate file types. ARTWORKSIGN SURVEY DOUBLE FACE - 12" SA ALUMINUM CABINET PAINTED 313 DARK BRONZE. - .150 PAN FORMED EMBOSSED SOLAR GRADE POLYCARBONATE FACES. - FLUORESCENT ILLUMINATION. CAMEOS - FORMED POLYCARBONATE WITH PRINTED GRAPHICS SECOND SURFACE WITH LED ILLUMINATION. - ALUMINUM RETURNS AND BACKS PAINTED 313 DARK BRONZE. - FORMED ABS POLE COVER PAINTED 313 DARK BRONZE. 9/23/14 COLORS WHITE PMS 201 BURGUNDY HAIR PMS 299 BLUE PMS 439 BROWN 313 DARK BRONZE PMS 698 PINK PMS 186 RED HAIR PMS 186 RED E122574