HomeMy WebLinkAbout20230928 289 Lake Ave Solar Panels Application**HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED** 12 OFFICE VW CITY OF SARATOGA SPRINGS s DESIGN REVIEW COMMISSION P� v CITY HALL - 474 BROADWAY •/NC0R�'OrATEO SARATOGA SPRINGS, NEW YORK 12866-2296 TEL: 518-587-3550 X2533 www.saratoga-springs.org APPLICATION FOR: ARCHITECTURAL / HISTORIC REVIEW APPLICANT ($} OWNER( (If not AM cant) William & Maureen Hayes Name 289 Lake Ave Address - Saratoga Springs, NY 12866 Phone 617-285-2258 / 617-285-4154 Email williamhayesll@gmaii.com Identify primary contact person: IN Applicant mofhayes@gmail.com ❑ Owner ❑ Attorney/Agent (Application #) (Date received) (Project Title) Staff Review ATTORNEY/AGENT * An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant's interest in premises: PROPERTY INFORMATION ® Owner ❑ Lessee ❑ Under option to lease or purchase 289 Lake Ave, Saratoga Springs, NY 12866 166 10 .2 .21 Property Address/Location: Tax Parcel #: - 6/26/2023 (for example: /65.52 - 4 - 37) — Date Acquired by Owner: UR1 Current Zoning District: Property use: M Residential ❑ Non-residential/mixed-use Type of Review: El Architectural ❑ Historic ❑ Extension/modification (of current approval) Summary description of proposed action: Install 38 black solar panels on roof as part of a 15.2kw solar installation: 10 panels on east -facing roof (Elizabeth Street side of property) and 28 panels on south -facing roof (Lake Avenue side of property). Has a previous application been filed with the DRC for this property? ❑ No S Yes - date(s)? 8/1 /2023 #20220515 Revised 01/2021 A "complete" application consists of 1 hard gM (grig MD , and I electroniq copy of application &ALL other materials as required below: New Construction / Additions ❑ Color photographs showing site/exterior details of existing structures and adjacent properties ❑ Site plan, drawn to scale, showing existing & proposed construction, property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.); on no larger than Tx3' sheet — smaller preferred if legible ❑ Elevation drawings showing design of all sides of existing & proposed construction — label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2'x3' sheet — smaller permitted if legible ❑ Floor plans for proposed structure; on sheet no larger than 2'x3'— smaller permitted if legible ❑ Product literature, specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) ❑ Color photographs showing site/exterior details of existing structures and that illustrate affected features ❑ Elevation drawings showing all sides of existing & proposed construction — label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2'x3' sheet — smaller permitted if legible O Product literature, specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts onl (Front setbacks: UR-1 & wsr-HTR=30; UR-4=25'; UR-2, UR-3 & NCUD-1=10') - Installation, removal or change in material of drive- and walkways - Installation or removal of architectural, sculptural or vegetative screening over 3' in height - Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2' diameter) For any of above: ❑ Color photographs showing site/exterior details of existing structures, and of adjacent properties ❑ Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & jot coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2'x3' sheet — smaller preferred if legible ❑ Product literature, specifications and samples of proposed materials and colors Signage / Awnings ❑ Color photographs showing site/exterior details of existing structures, and adjacent properties ❑ Plan showing location of proposed sign/awning structure on building/premises: no larger than I I "x 17" ❑ Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware ❑ Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location ❑ Product literature, specifications and samples of proposed materials and colors Demolition Color photographs showing site/exterior details of existing structures, and of adjacent properties ❑ Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale ❑ Written description of reasons for demolition and, in addition: ❑ For structures of "architectural/historical significance", demonstrate "good cause" why structure cannot be preserved ❑ For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a "contributing" structure in a National Register district (contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities ❑ Color photographs showing site/existing structures, and of adjacent properties ❑ Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale ❑ Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details ❑ Consult Article 240-12.22 of the City's Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 01/2021 Request for extension of current approval ❑ Identify date of original DRC approval: Current expiration date: Org. App. No. ❑ Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEAR Environmental Assessment Form ❑ Applicants proposing the following must complete "Part 1" of the SEQR Short Environmental Assessment Form (available here: http,//www.dec.oy.gov/docs/permits ej operations pdf/seafpartone pdf): - Construction or expansion of a multi -family residential structure (4 units +) Construction or expansion (exceeding 4,000 sq. ft. gross boor area) of a principal or accessory non-residential structure - Telecommunications facility, radio antennae, satellite dishes - Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? B No ❑ Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification I/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Commission. By the signature(s) attached hereto, 1/we certify that the information provided within this application and accompanying documentation is, to the best of.my/our knowledge, true and accurate. 1/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review of the Zoning Code of the City of Saratoga Springs. (applicant signature) (app icant ` nature) Date: 1 I 1 Date: A / 1 / :Z012_ 5 If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature: Owner Signature: Date: Date: Revised 01/2021 X CITY OF SARATOGA SPRINGS DESIGN REVIEW COMMISSION City Hall - 474 Broadway Saratoga Springs, New York 12866 ill!QLOR A T -,V Tel: 5 18-587-3550 x2533 www.saratoga-springs.org INSTRUCTIONS ARCHITECTURAL/ HisTopic RmEwAPPLICATION I . ELIGIBILITY: An applicant to the Design Review Commission for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2. COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRC will gDly consider properly completed applications that contain I origingi and I digital version of the aRplication and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!! Architectural Review District Historic Review District • any exterior changes that require a building permit * Installation or exterior change to a structure requiring a • any change in exterior building materials building or demolition permit • a new, or change to an existing, sign or sign structure * any material change to exterior of a structure including: • demolition of a structure - addition or removal of exterior architectural features - installation, removal or material changes to exterior Within a non-residential zoning district: building elements such as roof, siding, windows, doors, • a change in exterior building color porches, etc. • installation of an awning - enclosure or screening or buildings openings such as windows, doors, porches, etc. installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. Within a front yard setback: installation, removal or material changes to drive- or walkways installation or removal of architectural, sculptural or vegetative screening that exceeds 3' in height installation of accessory utility structures or radio/satellite transmission/reception devices over 2' in diameter • a change in exterior building color within a non- residential zoning district • a new, or change to an existing, sign or awning • installation of telecommunications facilities Note Ordinary maintenance or repair that does not involve a change in material, design or outer appearance_�� is 'e is exempt from Historic or Architectural Review. Revised 01/2021 4. DESIGN GUIDELINES: The Design Review Commission will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: • Height — consistent with historic form and context of site and surrounding properties • Scale — relationship of structure and its architectural elements to human size, form, perception • Proportion — relationship among building elements including front facade, windows, and doors • Rhythm — pattern resulting from repeating building elements such as door/window openings, columns, arches, and other facade elements • Directional Expression — compatibility with horizontal & vertical expression of surrounding structures • Massing & Open Space — relationship of structure to open space between it and adjoining buildings • Setback — compatibility with surrounding structures • Compatibility of the following with surrounding structures/properties: Major building elements (storefronts, doors, windows, roof) Building materials Color — (in non-residential zoning districts only) 5. DECISIONS: The Design Review Commission may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of the filing date unless the project has sufficiently commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6. AGENDA DATE: Check City's website (www.saratoga-springs.o ) for meeting dates. Applications are placed on an agenda on first -come, first -served basis as determined by the completeness of the application. 7. APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance". REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT. ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Commission responsibilities may be found in the City's Zoning Ordinance available in City Hall and on the City's web site at http://www.sarat2ga-springs.org/544/Zoning-Ordinance. Revised 01/2021 2021 LAND USE BOARD FEE WORKSHEET OPED Fees Type 2021 Fee Application to Zoning Board of Appeals [1] [21 TOTAL #VARIANCE Use Variance $1100+$50/app Area Variance- Residential $275/var+$50/app+$125 each add'I variance Area Variance- Multi -Family, Comm, Mixed -Use $660/var+$50/app+$200 each add'I variance Interpretations $550+$50/app Post -Work Application Fee Add 50%App fee+$50/app Variance extensions 50%ofAppfee+$50/app Application to Design Review Commission [S] TOTAL #STRUCTURE Demolition $385 Residential Structures Principal $55 Accessory $55 Extension $35 Modification $55 Multi -Family, Comm, Mixed -Use Structures Sketch $165 Principal $550 Extension $200 Modification $330 Multi -Family, Comm, Mixed -Use Accessory, Signs, Awnings Principal $140 Extension $75 Modification $140 Post -Work Application Fee Add 50%App fee Application to Planning Board [1] TOTAL #STRUCTURE Special Use Permit (21 $990+$50/app Special UsePermit-extension $330 Special UsePermit -modification [21 $450+$50/app Site Plan Review -incl. PUD: Sketch Plan $330 Residential $330+$200/unit Residential -extension $200 Residential - modification $400 Non-residential $ 660+$130/1000 sf Non -Residential -extension $300 Non -Residential -modification $650 Subdivision-incl.PUD: TOTAL #LOTS Sketch Plan $330 Preliminary Preliminary Approval [2] Residential: 1-5 lots $660+$50/app Residential: 6-10 lots $990+$50/app Residential:11-20 lots $1320+$50/app Residential: 21+ lots $1650+50/app Residential -extension $330 Final Approval [2] Residential $1320+$175/lot+$50/app Non- Residential $2000/lot+$50/app Final Approval Modification [2] Residential $330 +$50/app Non -Residential $550 +$ 50/app Final Approval Extension Residential $135 Non- Residential $330 Other: TOTAL #LOT/ACRE Post -Work Application Fee Add 50% App fee Lot Line Adjustment $350 Letter of Credit - modification or extension $440 Letter of Cred it - collection up to 1%ofLoC Recreation Fee $2000/10torunit Land Disturbance $660+$55/acre SEQRA EIS Review (Draft & Final) TBD Legal Noticing ff PB requires Public Hearing $50/app [11 Fees are based on per structure, except where noted. $0.00 TOTAL DUE [21 Legal ad required; includes City processing and publishing ForAdministrative Use Total Paid at Intake Revised Fee Balance Due _/_/_ Balance Paid Staffapproval SYSTEM System Size 15.2NN Panel Hyundai Heavy HiS-S400YFfBN x88 Industries Co, System Summary Solar Environment LLC Ml Ago y a r • A S Olt ar a • .. '. gr * #fir ift HYUNDAI SOLAR MODULE I(H Dual Black Max HiS-S385YH(BK) HiS-S390YH(BK) SERIES HiS-S400YH(BK) HiS-S405YH(BK) Maximized Power Generation Increased total power output through capturing light from both the front and back of Bifacial solar modules. Back side power gain up to 25% of the front output depending on PV system design. t_1 `f Mechanical Strength Tempered glass and reinforced frame design withstand rigorous weather conditions such as heavy snow(5,400Pa) and strong wind(4,000Pa). Hyundai's Warranty Provisions 25 25-Year Product Warranty reties Materials and workmanship 25 25-Year Performance Warranty renes Initial year:98.0% Linear warranty after second year: with 0.54%p annual degradation, 85.0 % is guaranteed up to 25 years YR 2 5 1 WARRANTY Product&Performance I IM Half -Cut & IM Multi -Wire Technology Wires Improved current flow with half -cut technology and 9 thin wiring technology allows high module efficiency of up to 20.5%. It also reduces power generation loss due to micro -cracks. QQ UL / VDE Test Labs Hyundai's R&D center is an accredited test laboratory of both UL and VDE. About Hyundai Energy Solutions ♦Is V_ Anti -LID / PID Both LID(Light Induced Degradation) and PID(Potential Induced Degradation) are significantly reduced to ensure higher actual yield during lifetime. Reliable Warranty HYUNDAI Global brand with powerful financial strength provide reliable 25-year warranty. Established in 1972, Hyundai Heavy Industries Group is one of the most trusted names in the heavy industries sector and is a Fortune 500 company. As a global leader and innovator, Hyundai Heavy Industries is committed to building a future growth engine by developing and investing heavily in the field of renewable energy. As a core energy business entity of HHI, Hyundai Energy Solutions has strong pride in providing high -quality PV products to more than 3,000 customers worldwide. Certification V � Lam - UL61730 certified by UL. Type 1(for Fire Class A) emw• � =LI Printed Date: 0312022(final) www.hyundai-es.co.kr A HYUNDAI ENERGY SOLUTIONS Electrical Characteristics 385 '0a► a a 77 Nominal ► " 385 390 395 400 405 410 Open Circuit Voltagee 44.5 -- 44.8 - - 45.0 45.3 45.6 45.9 Short Circuit Current (lsc) 11.04 11.11 11.18 - - - 11.25 11.33 11.40 - 37.1 373 -- 37.5 - 37.7 37.9 -- 38.1 - Current at Pmax (IMPP) 10.40 10.47 - 10.54 ----- 10.61 10.69 10.76 Module19.3 19.5 19.8---- 20.0 20.3 20.5 L Cell Type -- Mono crystalline, 9busbarMaximum System Voltage 1,500 - 500 - _ Temperature Coefficient of Pmax - -0.347 Temperature Coefficient of .. _. _ -- -0.268 - -- Temperature r• +0.032 'All data at STC (Measurement tolerances Pmpp ±3%; Isc ; Voc±3%). Above data may be changed without prior notice. Additional ,rear.. $,k 4�„gai. `�..1',a,`4u'v e"v+, .'i.�dahailk.�,`:.u�z�'4`�f.•., a - - 4.:,`�.ata i+2: :'. "' ,x.§e,;.,'`"-'� 4 �'-�sy - 'Icla`iuiFp.. 7.iit to`�,�d�e 399 404 410 415 425 431 437 443 449 454 466 472 475 482 488 ------------ 494 506 513 Mechanical Characteristics Installation Safety Guide t 1,038 mm (W) x 1,924 mm (L) x 35 mm(H) • Only qualified personnel should install or --------.---...--._-___ _ perform maintenance. weightApprox, 21.1 kg • Be aware of dangerous high DC voltage. L _-- • Do not damage or scratch the rear surface Solar Cells 132 half cut bifacial cells (2 parallel x 66 half cells in series) of the module. _ -.- • Do not handle or install modules when they Output Cable :1,200mm / 4mm2 are wet. Connector: MC4 genuine connector Nominal Operating 45.5°C ± 2 Junction Box IP68, weatherproof, IEC certified (UL listed) Cell Temperature - --- Operating Temperature -40°C - +85°C BypassDiodes 3 bypass diodes to prevent power decrease by partial shade - - --- -- ----- - - - Maximum DC 1,500U System voltage Construction Front: 3.2mm, High Transmission, AR Coated Tempered Glass Encapsulant : EVA I Back Sheet: Black Meshed Transparent Backsheet Maximum 20A Reverse Current Anodized aluminum alloy type 6063 Module Diagram (unit:mm) Front Side View Rear Side View 0.5 10.5 12-W SLOT THRe T DETAIL A DETAIL B SECTION C-C' & D-D' Pdnted on F5C certified PSC e<ofiterdlypp- Maximum Test Load Front 5,400 Pa (113pA Rear 4,000 Pa (84pst) IN Curves Current [A] 12 70 �i B y 6 Irmdlame =1,000W10 4 - Operating Cell Temp=5°C - Operating Cell Temp= 25°C 2--Operatlng Ce"Tamp=45'C Z - Owong Temp = 65-c 0 0 10 20 30 40 50 Voltage[V] Current [A] 12 I.W. = i3ODOWlm' 10n2WW 6 = 600N/m'=600W/m� =40OWm' 'i12 =200w W 0 0 10 20 30 40 f0 Voltage[ V ] A HYUNDAI ENERGY SOLUTIONS