HomeMy WebLinkAbout20230893 351 Broadway Starbucks Windows & Door Glass Application10/16/23 FINISHED FLOOR0' -0"T/O CORNICE13' -5"123410(2)1112(7)13(7)FINISHED FLOOR0' -0"T/O CORNICE13' -5"123455557896910(2)1112(5)13LEGENDITEM TO BE DEMOLISHEDITEM TO BE RELOCATEDEXISTING ITEM TO REMAINKEYED NOTES1. ALL EXISTING WALLS, ROOFS, COLUMNS, CURBS, AND EXTERIOR FINISHES TO REMAIN UNLESS OTHERWISE NOTED. GC TO PROTECT THROUGHOUT THE COURSE OF DEMOLITION AND CONSTRUCTION.2. EXISTING LIGHTING FIXTURE TO REMAIN AS INDICATED.3. EXISTING STARBUCKS SIGN TO BE RELOCATED.4. EXISTING COFFEE SIGN TO BE DEMOLISH.5. EXISTING CANOPY TO REMAIN AS INDICATED.6. EXISTING ELECTRICAL PANEL TO REMAIN AS INDICATED.7. EXISTING WALL VENT TO REMAIN AS INDICATED.8. EXISTING FIRE ALARM TO REMAIN AS INDICATED.9. EXISTING FIRE DEPARTMENT CONNECTION TO REMAIN AS INDICATED.10. EXISTING LIGHTING FIXTURE TO BE DEMOLISHED. GCTO PATCH, REPAIR, AND PAINT TO MATCH EXISTING BUILDING CONDITIONS.11. EXISTING STOREFRONT SYSTEM DOOR TO BE DEMOLISHED AND REPLACED WITH CODE COMPLIANT DOUBLE PANE GLASS BY GC AS INDICATED.12. EXISTING STOREFRONT SYSTEM GLAZING TO BE DEMOLISHED AND REPLACED WITH CODE COMPLIANT DOUBLE PANE GLASS BY GC AS INDICATED.13. EXISTING STOREFRONT SYSTEM SPANDREL GLASS TO BE DEMOLISHED AND REPLACED WITH CODE COMPLIANT DOUBLE PANE GLASS BY GC AS INDICATED.GENERAL NOTESA. IF DURING DEMOLITION CONDITIONS ARE REVEALED THAT MAY JEOPARDIZE INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT, GENERAL CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY.B. GENERAL CONTRACTOR IS RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO DEMOLITION TO REVEAL FULL SCOPE OF WORK. NOTIFY STARBUCKS CONSTRUCTION MANAGER IF EXISTING CONDITIONS DEVIATE FROM CONSTRUCTION DOCUMENTS.C. REMOVE EXISTING INTERIOR WALL FINISH AS SHOWN. PATCH, REPAIR AND PREP. SUBSTRATE TO RECEIVE NEW FINISH. REMOVE WALL COVERINGS ON EXISTING WALLS TO REMAIN THAT FACE AREAS OF DEMOLITION. REMOVAL SHALL INCLUDE ANY RESIDUAL MATERIAL AFTER DEMOLITION, (I.E. PIECES OF WALL COVERING OR BACKING). REMOVAL OF ALL COVERINGS IS TO BE DONE W/O DAMAGING THE EXISTING WALL SURFACE TO REMAIN. ALSO REMOVE WALL DEVICES AND ITEMS MOUNTED TO WALLS.G. VERIFY WITH STARBUCKS CONSTRUCTION MANAGER ACCESS TO THE DEMOLITION AREA, INGRESS AND EGRESS ROUTES FOR MATERIAL AND EQUIPMENT.H. PROTECT EXISTING FLOORS, WALLS AND CORNERS TO REMAIN ALONG WORK ACCESS ROUTES.I. CONTAIN DUST AND DEBRIS WITHIN THE DEMOLITION AREA.J. THE GENERAL CONTRACTOR SHALL PERFORM WORK IN A MANNER THAT DOES NOT DAMAGE THE EXISTING STRUCTURE. DEMOLITION SHALL NOT COMPROMISE THE STRUCTURAL INTEGRITY OF ANY WALLS, FLOORS, CEILINGS, SUPPORTS, STRUCTURE, ETC. TO REMAIN.K. ALL DEMOLITION MATERIALS AND DEBRIS SHALL BE DISPOSED OF ACCORDING TO FEDERAL, STATE AND LOCAL REGULATIONS.L. AT LOCATIONS WHERE EXISTING WALLS ARE TO BE REMOVED NEAR EXISTING WALLS TO REMAIN, PERFORM DEMOLITION WITHOUT DISTURBING EXISTING ELEMENTS TO REMAIN. WALLS TO REMAIN SHALL BE INTACT AND HAVE A NEAT SURFACE.M. REFER TO "ITEMS TO BE PRESERVED" LIST FOR ITEMS THAT SHALL BE SALVAGED FOR RELOCATION. VERIFY WITH OWNER FOR ON SITE STORAGE LOCATION OF SALVAGED ITEMS.D. REMOVE EXISTING FLOORING AS SHOWN. PATCH, REPAIR AND PREP. SUBSTRATE TO RECEIVE NEW FINISH. REMOVAL OF EXISTING FLOORING INCLUDES, BUT IS NOT LIMITED TO REMOVAL OF EXISTING CERAMIC TILE, CARPET OR VINYL TILE FLOORING AND ASSOCIATED WALL BASE. SUBFLOOR TO BE STRIPPED OF ALL COVERING/FINISH AND CLEANED TO REMOVE EXISTING ADHESIVE, GROUT, MORTAR, DIRT AND COATINGS. FINAL SURFACE TO BE STREAK-FREE WITH NO MACHINE MARKS AND/OR SMOOTH, STABLE AND LEVEL. PROVIDE LEVELING WHERE NECESSARY TO ACCOMMODATE NEW FINISHES.E. DEMOLITION PLANS REPRESENT APPROXIMATE LOCATION OF EXISTING WALLS TO BE DEMOLISHED. FIELD VERIFY TYPE OF CONSTRUCTION AND HEIGHT OF WALLS. PLANS DO NOT NECESSARILY INDICATE ALL DEMO WALLS, COUNTERS, HANDRAILS, WALL PROTECTION, CLOSETS, SINKS ETC. PRIOR TO DEMOLITION, FIELD VERIFY THAT WALLS TO BE REMOVED DO NOT PROVIDE SUPPORT FOR EXISTING BUILDING ELEMENTS AND EXISTING CONSTRUCTION TO REMAIN. NOTIFY STARBUCKS CONSTRUCTION MANAGER IF DEMOLITION WALLS SUPPORT EXISTING BUILDING ELEMENTS.F. DEMOLISH AND REMOVE DOORS, VINYL BASE, CONDUIT, WIRING, DUPLEXES, DATA OUTLETS, CABLES, SHELVING, METAL STUD AND GYPSUM BOARD WALLS, CLOSETS, CABINETS, FILES, COUNTERS, WOOD MOLDING, SHELVES AND ENCLOSURES WHERE APPLICABLE.N. DAMAGED FIREPROOFING SHALL BE REPAIRED/REPLACED TO MATCH EXISTING.O. THE GENERAL CONTRACTOR SHALL DEMOLISH ANY EXISTING ABANDONED VOICE/DATA CABLING AND DEAD OR NON-USE ELECTRICAL BACK TO PANEL. ALL RECEPTACLES NOT REUSED ARE TO BE REMOVED, PATCHED AND PAINTED.P. REMOVAL OF LOW VOLTAGE EQUIPMENT, PERTAINING TO DATA/COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED BY THE STARBUCKS CONSTRUCTION MANAGER PRIOR TO REMOVAL. SALVAGED EQUIPMENT SHALL BE STORED IN A CLIMATE CONTROLLED ENVIRONMENT FOR FUTURE INSTALLATION.Q. LABEL ALL ITEMS AND PROPERLY STORE FOR RE-INSTALL.2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134(206) 318-1575SHEET NUMBER:SHEET TITLE:SCALE: AS SHOWNSTORE #:PROJECT #:PROJECT NAME:PROJECT ADDRESS:STARBUCKS COFFEE COMPANYC 2017 STARBUCKS COFFEE COMPANYRTHESE DRAWINGS AND PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION i2021.04.23IN ASSOCIATION WITH THE ARCHITECT:45 WEST 21st STREET, SUITE 403NEW YORK, NY 10010212.904.0432R H SWEERS II, RH SWEERS ARCHITECTPROPRIETORRHS@SWEERSARCH.COMALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTENCONSENT OF THE ARCHITECT. THIS DOCUMENT IS INTENDED SOLELY FOR THE CONSTRUCTION OF THE PROJECT NAMED HEREIN AND SHALL NOT BE USED BY ANY OTHER CONSTRUCTION WITHOUT WRITTEN CONSENT OF THE ARCHITECT.THIS DRAWING WAS PREPARED UNDER MY SUPERVISION AND I DISCLAIM ANY RESPONSIBILITY FOR THE EXISTING BUILDING CONSTRUCTION ELEMENTS, SITE CONDITIONS, OR ANY DOCUMENTS WHICH DO NOT BEAR MY SEAL.B I D / P E R M I T S E T - I N T E N D E D F O R C O N S T R U C T I O N U S EDESIGN MANAGER:ENGINEER OF RECORD:ISSUE DATE:5/3/2023 2:43:38 PMY:\2022 PROJECTS\Starbucks\22SB19 Saratoga Springs, NY\06 Electronic Drawing\230503_03481-104 Saratoga Springs,NY_Model_.rvtD201SARATOGA SPRINGS,NY351 BROADWAY, NY 12866DEMOLITION EXTERIORELEVATIONANNIE SONGKHL ENGIENEERS03481-10405-05-202307351Scale:1/4" = 1'-0"1DEMOLITION EXTERIOR ELEVATION EASTScale:1/4" = 1'-0"2DEMOLITION EXTERIOR ELEVATION SOUTHNOTE: ALL SCOPE FOR BUILDING EXTERIOR FACADE IS UNDER SEPARATE PERMIT BY LL.02' 4' 8'Scale: 1/4" = 1'-0"Revision ScheduleRev Date By DescriptionSIGNED 05/03/2023 1. EXISTING EXTERIOR FINISHES, TRIMS AND COPING BY LANDLORD TO REMAIN AS-IS.2. LANDLORD TO PROVIDE J-BOX FOR BUILDING SIGNAGE. COORDINATE LOCATION WITH SIGNAGE VENDOR SHOP DRAWINGS.3. LANDLORD TO PROVIDE SIGNAGE DISCONNECT AS REQUIRED.4. LANDLORD TO PROVIDE PLYWOOD BLOCKING FOR EXTERIOR SIGNAGE. EXTEND BLOCKING 8" (205MM) MIN. BEYOND EDGE OF SIGNAGE.5. NEW LOCATION OF EXISTING STARBUCKS SIGN.6. EXISTING EXTERIOR BUILDING SCONCES BY LANDLORD TO REMAIN AS INDICATED, PER SB SPECIFICATIONS.7. STARBUCKS PRIMARY AND SECOND ENTRANCE DOOR BY LANDLORD AS INDICATED.8. REPLACEMENT OF ALL GLASS PANELS PER LOCAL CODE. GC TO PROVIDE AND INSTALL BY BASE BUILDING STOREFRONT VENDOR: AGM GLASS - MIKE HAVERLY (518) 858-3049 MIKE@AGMGLASS.COM. 9. EXISTING WALL VENT TO REMAIN AS INDICATED.10. EXISTING CANOPY BY LL TO REMAIN AS INDICATED AT STOREFRONT.11. EXISTING FIRE DEPARTMENT CONNECTION TO REMAIN AS INDICATED.12. EXISTING STOREFRONT SYSTEM TO REMAIN. GC TO REPLACE SPRANDEL GLASS PER LOCAL CODE.13. EXISTING ELECTRICAL PANEL TO REMAIN AS INDICATED.14. EXISTING FIRE ALARM TO REMAIN AS INDICATED.15. GC TO PATCH, REPAIR, AND PAINT TO MATCH EXISTING BUILDING CONDITIONS WHERE PREVIOUS SCONCE WAS REMOVEDA. GENERAL CONTRACTOR TO COORDINATE AND SCHEDULESIGNAGE INSTALLATION WITH THE SIGNAGE CONTRACTORPROVIDING A MINIMUM SCHEDULING NOTICE OF 4 WEEKS AND 1 WEEK PRIOR TO SCHEDULED DATE OF INSTALLATION. CONSTRUCTION MANAGER TO PROVIDE GENERAL CONTRACTOR WITH SIGNAGE CONTRACTOR CONTACT INFORMATION.B. GENERAL CONTRACTOR SHALL COORDINATE WITHELECTRICAL CONTRACTOR TO FURNISH AND INSTALLELECTRICAL CIRCUITS INCLUDING ALL CONDUIT, WIRE,CONNECTIONS AND BREAKER AT PANEL BOARD NECESSARY TO SERVE SIGNAGE.C. GENERAL CONTRACTOR TO PROVIDE FIRE TREATED WOOD STUD BLOCKING OR EQUIVALENT TO SUPPORT SIGNAGE.D. SIGNAGE CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ANY AND ALL ALLOWABLE MONUMENT OR POLE SIGNAGE AND PROVIDE SHOP DRAWING(S) PRIOR TO FABRICATION TO THE STARBUCKS DESIGNER FOR APPROVAL.E. SIGNAGE CONTRACTOR TO INSTALL SIGNAGE INCOMPLIANCE WITH LOCAL CODES AND OBTAIN PERMIT.F. SIGNAGE CONTRACTOR TO SUPPLY SHOP DRAWINGS TOCONSTRUCTION MANAGER AND TO THE GENERALCONTRACTOR AS NEEDED. GENERAL CONTRACTOR TONOTIFY CONSTRUCTION MANAGER IMMEDIATELY IF SHOPDRAWINGS OR INSTALLATION IS IN DISCREPANCY WITHARCHITECTURAL DRAWINGS.G. GENERAL CONTRACTOR TO CLEAN, PATCH ANDREPAIR EXISTING EXTERIOR AS REQUIRED.KEYED NOTESGENERAL NOTESLEGENDEXISTING ITEM TO REMAINITEMS TO BE REUSED / RELOCATEDFINISHED FLOOR0' -0"T/O CORNICE13' -5"EQ10' - 10"EQ123456711910101010888814111312EQEQD10205C15FINISHED FLOOR0' -0"T/O CORNICE13' -5"EQ10' - 10"EQ123456788812121212EQEQD10449D152401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134(206) 318-1575SHEET NUMBER:SHEET TITLE:SCALE: AS SHOWNSTORE #:PROJECT #:PROJECT NAME:PROJECT ADDRESS:STARBUCKS COFFEE COMPANYC 2017 STARBUCKS COFFEE COMPANYRTHESE DRAWINGS AND PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION i2021.04.23IN ASSOCIATION WITH THE ARCHITECT:45 WEST 21st STREET, SUITE 403NEW YORK, NY 10010212.904.0432R H SWEERS II, RH SWEERS ARCHITECTPROPRIETORRHS@SWEERSARCH.COMALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTENCONSENT OF THE ARCHITECT. THIS DOCUMENT IS INTENDED SOLELY FOR THE CONSTRUCTION OF THE PROJECT NAMED HEREIN AND SHALL NOT BE USED BY ANY OTHER CONSTRUCTION WITHOUT WRITTEN CONSENT OF THE ARCHITECT.THIS DRAWING WAS PREPARED UNDER MY SUPERVISION AND I DISCLAIM ANY RESPONSIBILITY FOR THE EXISTING BUILDING CONSTRUCTION ELEMENTS, SITE CONDITIONS, OR ANY DOCUMENTS WHICH DO NOT BEAR MY SEAL.B I D / P E R M I T S E T - I N T E N D E D F O R C O N S T R U C T I O N U S EDESIGN MANAGER:ENGINEER OF RECORD:ISSUE DATE:5/3/2023 2:42:49 PMY:\2022 PROJECTS\Starbucks\22SB19 Saratoga Springs, NY\06 Electronic Drawing\230503_03481-104 Saratoga Springs,NY_Model_.rvtA201SARATOGA SPRINGS,NY351 BROADWAY, NY 12866BUILDING EXTERIORELEVATIONSANNIE SONGKHL ENGIENEERS03481-10405-05-202307351Scale:1/4" = 1'-0"2BUILDING EXTERIOR ELEVATION SOUTHScale:1/4" = 1'-0"1BUILDING EXTERIOR ELEVATION EAST02' 4' 8'Scale: 1/4" = 1'-0"NOTE: STOREFRONT VENDOR TO FIELD VERIFY DIMENSIONAL NEEDS FOR NEW GLASS REPLACEMENT.Revision ScheduleRev Date By DescriptionSIGNED 05/03/2023 CE marking confirms that a product complies with its relevant harmonised European Norm. The CE marking label for each product, including declared values, can be found at www.pilkington.com/CE This publication provides only a general description of the product. Further, more detailed, information may be obtained from your local supplier of Pilkington products. It is the responsibility of the user to ensure that the use of this product is appropriate for any particular application and that such use complies with all relevant legislation, standards, codes of practice and other requirements. To the fullest extent permitted by applicable laws, Nippon Sheet Glass Co. Ltd. and its subsidiary companies disclaim all liability for any error in or omission from this publication and for all consequences of relying on it. Pilkington, “Optifloat” and “Optiwhite” are trademarks owned by Nippon Sheet Glass Co. Ltd, or a subsidiary thereof. Low-e 4th Surface Commercial Technology Pilkington Energy Advantage™ Low-e How is glazing performance improved? Cold Weather Conditions The coating on the #2 surface reduces room heat (or far IR energy) loss by reflecting it back toward the space. By adding a second low-e coating to the #4 surface the thermal insulation is further improved. More infrared heat (room heat) is reflected back into the building. For additional information visit www.pilkington.us/technicalbulletins: l ATS 193 Low-e 4th Surface Technology: Guidelines for use l ATS 137-4 Improvements in the Appearance of Installed Pilkington Energy Advantage™ l ATS 138 How Low-e Glass Works l ATS 138-D Window Energy Efficiency with Multiple Low-e Coatings Pyrolytic Power Pilkington Energy Advantage™ Low-e is coated using a pyrolytic process, which allows for the coating to be chemically-bonded to the glass at a molecular level. This process produces a coating which is extremely durable and will not scratch or degrade over time. The coating has been used globally for over 20 year with proven success. Enhanced thermal performance without investing in triple-pane windows. l Fewer low-e products to inventory, with installation on #2 and #4 surfaces l No additional raw materials required l No additional capital investments necessary l Easily integrated into current fabrication process l Lighter construction l Less reflection than with triple glazing l Durability of a pyrolytic l No edge deletion required for an IGU l Easily handled, tempered, cut, bent, laminated, insulated and heat-strengthened l Virtually unlimited shelf-life Here's how it works. Pilkington Energy Advantage™ Low-e coatings applied to the #2 and #4 surfaces of an insulating unit reduce the center of glass U-factor by about 20%, compared to an IGU with a pyrolytic low-e and an uncoated clear lite. This proven technology improves thermal performance in a new or reglazed commercial building. Durability is critical for coatings applied to the 4th surface of an insulating unit. Pyrolytic coatings are extremely durable and difficult to damage. Pilkington pyrolytic coating technology has been used on exposed surfaces successfully for over 20 years globally. With superior clarity, unrivaled by any other pyrolytic glass, Pilkington Energy Advantage™ has been used for more than 10 years in North America as a 4th Surface Low-e product. Features and Benefits l Durability of a pyrolytic l Low U-factor and reduced solar heat gain l Superior thermal control l Improved clarity l High light transmittance l Energy savings l Easy to clean surface with standard techniques l Superior aesthetics for any building l Can help projects achieve LEED® credit l No additional SKUs Lower U-factor l Improved Clarity l Greater Energy Savings. AIRSPACE1 2 3 4 INSIDEOUTSIDE AIRSPACE1 2 43 Low-e Coating Low-e Coating INSIDEOUTSIDE Warm Weather Conditions The low-e coating on the #4 surface reflects more solar heat than one lite of low-e glass, reducing cooling loads. Low-e 4th Surface Commercial Technology with Pilkington Energy Advantage™ Low-e. Low-e Coating Low-e Coating Nominal Glass Thickness Visible Light2 Solar Energy2 U-Factor5 Solar Heat Gain Coefficient7Shading Coefficient8Transmittance3Reflectance Transmittance3%Reflectance4%UV Transmittance2%U.S. Summer*U.S. Winter*European in.mm AirArgonAirArgonAirArgonOutsideInsidePilkington Energy Advantage™ Outer Lite (#2 surface) and Pilkington Optifloat™ Clear Inner Lite 3/16 5 74 17 17 55 14 41 0.33 0.28 0.33 0.29 1.8 1.5 0.63 0.73 1/4 6 73 16 17 52 13 37 0.33 0.28 0.33 0.29 1.8 1.5 0.62 0.71 5/16 8 71 15 16 47 12 32 0.33 0.28 0.33 0.28 1.8 1.5 0.59 0.67 3/8 10 69 15 16 43 12 29 0.32 0.27 0.33 0.28 1.8 1.5 0.56 0.64 1/2 12 67 15 16 39 11 27 0.32 0.28 0.32 0.28 1.8 1.5 0.53 0.61 Pilkington Energy Advantage™ Outer Lite (#2 surface) and Pilkington Energy Advantage™ Inner Lite (#4 surface) 3/16 5 69 18 19 49 15 33 0.24 0.21 0.26 0.23 1.6 1.3 0.59 0.68 1/4 6 68 17 18 47 14 29 0.24 0.21 0.26 0.23 1.5 1.3 0.58 0.66 5/16 8 66 17 18 42 13 26 0.24 0.21 0.26 0.23 1.5 1.3 0.54 0.62 3/8 10 64 16 17 38 12 23 0.24 0.21 0.26 0.22 1.5 1.3 0.51 0.59 1/2 12 63 16 18 36 11 24 0.24 0.21 0.26 0.23 1.5 1.3 0.49 0.57 Double Silver Sputter Coat Low-e Outer Lite (#2 surface) and Pilkington Energy Advantage™ Inner Lite (#4 surface) 3/16 5 66 13 15 31 32 16 0.21 0.17 0.23 0.20 1.3 1.1 0.36 0.42 1/4 6 65 12 14 30 30 14 0.21 0.17 0.23 0.19 1.3 1.1 0.36 0.41 5/16 8 63 12 14 29 25 13 0.21 0.17 0.23 0.19 1.3 1.1 0.35 0.40 3/8 10 62 12 14 27 23 12 0.21 0.17 0.23 0.19 1.3 1.0 0.35 0.40 1/2 12 61 11 13 26 18 11 0.21 0.17 0.23 0.19 1.3 1.0 0.34 0.39 Triple Silver Sputter Coat Low-e Outer Lite (#2 surface) and Pilkington Energy Advantage™ Inner Lite (#4 surface) 3/16 5 59 13 16 22 39 4 0.20 0.16 0.23 0.19 1.3 1.0 0.26 0.30 1/4 6 58 13 15 22 36 4 0.20 0.16 0.23 0.19 1.3 1.0 0.26 0.30 5/16 8 56 12 15 21 31 4 0.20 0.16 0.23 0.19 1.3 1.0 0.26 0.30 3/8 10 55 12 14 20 28 3 0.20 0.16 0.22 0.19 1.3 1.0 0.26 0.30 1/2 12 54 12 15 19 22 3 0.20 0.16 0.22 0.19 1.3 1.0 0.26 0.30 Pilkington Energy Advantage™ OW Outer Lite (#2 surface) and Pilkington Optiwhite™ Low Iron Inner Lite 1/4 6 76 17 18 68 17 59 0.33 0.28 0.33 0.29 1.8 1.5 0.70 0.81 Pilkington Energy Advantage™ OW Outer Lite (#2 surface) and Pilkington Energy Advantage™ OW Inner Lite (#4 surface) 1/4 6 70 18 20 60 18 47 0.24 0.21 0.26 0.23 1.5 1.3 0.66 0.76 Double Silver Sputter Coat Low-e Outer Lite (#2 surface) and Pilkington Energy Advantage™ OW Inner Lite (#4 surface) 1/4 6 66 13 15 32 30 17 0.21 0.17 0.23 0.19 1.3 1.1 0.37 0.42 Triple Silver Sputter Coat Low-e Outer Lite (#2 surface) and Pilkington Energy Advantage™ OW Inner Lite (#4 surface) 1/4 6 59 13 16 23 36 5 0.20 0.16 0.23 0.19 1.3 1.0 0.26 0.30 Performance Data 1, 10 An insulating unit consists of two lites of equal glass thickness, and a 1/2 in. airspace. *U.S. U-Factor (Btu/hr.sq ft. oF) is based on NFRC/ASTM standards, **European U-Factor (W/sq m K) is based on EN 410/673 (CEN) standard. All performance values are center-of-glass values calculated using the LBNL Window 6.3 program. See Pilkington Architectural Product Guide for explanation of references - 1, 10. The 'OW' descriptor in 'Pilkington Energy Advantage™ OW' indicates the base substrate is low iron, such as Pilkington Optiwhite™. October 2013 Pilkington North America 811 Madison Ave., Toledo, OH 43604-5684 Main Office: 419 247 3731 Fax: 419 247 4517 buildingproducts.pna@nsg.com www.pilkington.com/na Nominal Glass Thickness Visible Light2 Solar Energy2 U-Factor5 Solar Heat Gain Coefficient7Shading Coefficient8Transmittance3 %Reflec- tance4 %Transmittance3 %Reflectance4 %UV Transmittance2 %U.S. Summer U.S. Winter European6 in. mm OutsideInsideAirArgonAir ArgonAirArgonPilkington Solar-E™ (coating on #2 surface) outer lite and Pilkington Energy Advantage™ Low-e (coating on the #4 surface) inner lite Clear 1/4 6 49 11 17 32 9 26 0.24 0.22 0.26 0.23 1.6 1.3 0.41 0.47 5/16 8 48 11 17 29 9 23 0.24 0.21 0.26 0.23 1.5 1.3 0.40 0.45 Pilkington Solar-E™ Plus (coating on #2 surface) outer lite and Pilkington Energy Advantage™ Low-e (coating on the #4 surface) inner lite Blue-Green 1/4 6 34 8 17 18 6 12 0.25 0.22 0.26 0.23 1.6 1.3 0.27 0.31 5/16 8 32 7 16 15 6 9 0.24 0.22 0.26 0.23 1.6 1.3 0.24 0.28 EverGreen 1/4 6 31 8 17 13 6 5 0.25 0.22 0.26 0.23 1.6 1.3 0.22 0.25 5/16 8 28 7 17 11 5 3 0.24 0.22 0.26 0.23 1.6 1.3 0.19 0.22 Graphite Blue 1/4 6 23 6 16 17 6 13 0.25 0.22 0.26 0.20 1.6 1.3 0.29 0.34 5/16 8 25 7 16 16 6 11 0.24 0.22 0.26 0.23 1.6 1.3 0.26 0.29 Arctic Blue 1/4 6 25 6 16 13 5 7 0.25 0.22 0.26 0.23 1.6 1.3 0.21 0.25 5/16 8 22 6 16 11 5 5 0.24 0.22 0.26 0.23 1.6 1.3 0.19 0.22 Grey 1/4 6 20 6 17 14 6 8 0.25 0.22 0.26 0.23 1.6 1.3 0.23 0.26 5/16 8 16 6 16 11 5 5 0.24 0.22 0.26 0.23 1.6 1.3 0.20 0.23 Pilkington Eclipse Advantage™ (coating on #2 surface) outer lite and Pilkington Energy Advantage™ Low-e (coating on #4 surface) inner lite Clear 1/4 6 56 30 30 41 22 19 0.25 0.23 0.27 0.24 1.6 1.4 0.51 0.58 5/16 8 55 29 30 37 20 17 0.25 0.23 0.27 0.24 1.6 1.4 0.48 0.55 Blue-Green 1/4 6 48 22 29 26 12 10 0.25 0.23 0.27 0.24 1.6 1.4 0.35 0.40 5/16 8 44 20 29 21 11 8 0.25 0.23 0.27 0.24 1.6 1.4 0.30 0.35 EverGreen 1/4 6 40 18 30 18 9 5 0.25 0.23 0.27 0.24 1.6 1.4 0.26 0.30 5/16 8 36 15 29 14 8 3 0.25 0.23 0.27 0.24 1.6 1.4 0.23 0.26 Arctic Blue 1/4 6 33 14 29 17 9 7 0.25 0.23 0.27 0.24 1.6 1.4 0.26 0.30 5/16 8 27 11 29 13 7 5 0.25 0.23 0.27 0.24 1.6 1.4 0.22 0.25 Bronze 1/4 6 32 13 29 24 11 7 0.25 0.23 0.27 0.24 1.6 1.4 0.34 0.39 5/16 8 26 10 28 19 9 5 0.25 0.23 0.27 0.24 1.6 1.4 0.29 0.33 Grey 1/4 6 27 11 29 20 9 7 0.25 0.23 0.27 0.24 1.6 1.4 0.30 0.35 5/16 8 21 8 29 15 7 5 0.25 0.23 0.27 0.24 1.6 1.4 0.25 0.29 Performance Data 1, 10 To the fullest extent permitted by applicable laws, Nippon Sheet Glass Co. Ltd. and its subsidiary companies disclaim all liability for any error in or omission from this publication and for all consequences of relying on it. An insulating unit consists of two lites of equal glass thickness, and a 1/2 in. airspace. *U.S. U-Factor (Btu/hr.sq ft. oF) is based on NFRC/ASTM standards, **European U-Factor (W/sq m K) is based on EN 410/673 (CEN) standard. All performance values are center-of-glass values calculated using the LBNL Window 6.3 program. See Pilkington Architectural Product Guide for explanation of references - 1, 10.