HomeMy WebLinkAbout20230314 167 Spring Exterior Modifications ApplicationRevised 01/2021
APPLICATION FOR:
ARCHITECTURAL / HISTORIC REVIEW
APPLICANT(S)* OWNER(S) (If not applicant) ATTORNEY/AGENT
Name
Address
Phone / / /
Email
Identify primary contact person: Applicant Owner Attorney/Agent
* An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question.
Applicant’s interest in premises: Owner Lessee Under option to lease or purchase
PROPERTY INFORMATION
Property Address/Location: Tax Parcel #: . - -
(for example: 165.52 – 4 – 37 )
Current Zoning District: Property use: Residential Non-residential/mixed-use
Type of Review: Architectural Historic Extension/modification (of current approval)
Summary description of proposed action:
Has a previous application been filed with the DRC for this property? No Yes – date(s)? _____________________
-App. No.(s)? _________________
Date Acquired by Owner: _________________
**HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED**
CITY OF SARATOGA SPRINGS
DESIGN REVIEW COMMISSION
CITY HALL - 474 BROADWAY
SARATOGA SPRINGS, NEW YORK 12866-2296
TEL: 518-587-3550 X2533
www.saratoga-springs.org
[FOR OFFICE USE]
_______________
(Application #)
____________
(Date received)
__________________________
(Project Title)
Staff Review _______________
**A “complete” application consists of 1 hard copy (original) , and 1 electronic copy of application & ALL other
materials as required below:
New Construction / Additions
Color photographs showing site/exterior details of existing structures and adjacent properties
Site plan, drawn to scale, showing existing & proposed construction, property lines & dimensions, required & proposed setbacks & lot
coverage, site features (fences, walks, trees, etc.); on no larger than 2’x3’ sheet – smaller preferred if legible
Elevation drawings showing design of all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture
& lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible
Floor plans for proposed structure; on sheet no larger than 2’x3’ – smaller permitted if legible
Product literature, specifications and samples of proposed materials and colors
Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only)
Color photographs showing site/exterior details of existing structures and that illustrate affected features
Elevation drawings showing all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp
type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible
Product literature, specifications and samples of proposed materials and colors
Within front yard setbacks in Historic Districts only (Front setbacks: UR-1 & INST-HTR=30’; UR-4=25’; UR-2, UR-3 & NCUD-1=10’)
-Installation, removal or change in material of drive- and walkways
-Installation or removal of architectural, sculptural or vegetative screening over 3’ in height
-Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2’ diameter)
For any of above:
Color photographs showing site/exterior details of existing structures, and of adjacent properties
Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot
coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2’x3’ sheet – smaller
preferred if legible
Product literature, specifications and samples of proposed materials and colors
Signage / Awnings
Color photographs showing site/exterior details of existing structures, and adjacent properties
Plan showing location of proposed sign/awning structure on building/premises: no larger than 11”x17”
Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type,
dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware
Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location
Product literature, specifications and samples of proposed materials and colors
Demolition
Color photographs showing site/exterior details of existing structures, and of adjacent properties
Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale
Written description of reasons for demolition and, in addition:
For structures of “architectural/historical significance”, demonstrate “good cause” why structure cannot be preserved
For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a
“contributing” structure in a National Register district (contact City staff), provide plans for site development following demolition -
include a timetable and letter of credit for project completion
Telecommunication facilities
Color photographs showing site/existing structures, and of adjacent properties
Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale
Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details
Consult Article 240-12.22 of the City’s Zoning Ordinance and City staff to ensure compliance with requirements for visual impact
assessment and existing and proposed vegetative screening
Revised 01/2021
Revised 01/2021
Request for extension of current approval
Identify date of original DRC approval: ______________Current expiration date: ________________ Org. App. No. ____________
Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood.
SEQR Environmental Assessment Form
Applicants proposing the following must complete “Part I” of the SEQR Short Environmental Assessment Form (available here:
http://www.dec.ny.gov/docs/permits_ej_operations_pdf/seafpartone.pdf):
-Construction or expansion of a multi-family residential structure (4 units +)
-Construction or expansion (exceeding 4,000 sq. ft. gross floor area) of a principal or accessory non-residential structure
-Telecommunications facility, radio antennae, satellite dishes
-Demolition
Disclosure
Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law
Section 809) in this application?
No Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this
application.
Certification
I/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance
before the Design Review Commission.
By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying
documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing
false or misleading information is grounds for immediate denial of this application.
I/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property
associated with this application for purposes of conducting any necessary site inspections relating to this application.
Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural
Review of the Zoning Code of the City of Saratoga Springs.
Date:
(applicant signature)
Date:
(applicant signature)
If applicant is not the currently the owner of the property, the current owner must also sign.
Owner Signature: Date:
Owner Signature: Date:
Revised 01/2021
INSTRUCTIONS
ARCHITECTURAL / HISTORIC REVIEW APPLICATION
1.ELIGIBILITY: An applicant to the Design Review Commission for Architectural Review or Historic Review
must be the property owner(s) or lessee, or have an option to lease or purchase the property in question.
2.COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is
complete. The DRC will only consider properly completed applications that contain 1 original and 1
digital version of the application and ALL other required materials as indicated on the application.
HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!!
3.ACTIONS REQUIRING REVIEW:
Architectural Review District Historic Review District
•any exterior changes that require a building permit
•any change in exterior building materials
•a new, or change to an existing, sign or sign structure
•demolition of a structure
Within a non-residential zoning district:
•a change in exterior building color
•installation of an awning
•Installation or exterior change to a structure requiring a
building or demolition permit
•any material change to exterior of a structure including:
-addition or removal of exterior architectural features
-installation, removal or material changes to exterior
building elements such as roof, siding, windows, doors,
porches, etc.
-enclosure or screening or buildings openings such as
windows, doors, porches, etc.
-installation of utility, mechanical or misc. accessory
structures to the exterior of a building such as HVAC
equipment, solar panels, wind turbines, radio/satellite
transmission/reception devices, etc.
Within a front yard setback:
-installation, removal or material changes to drive- or
walkways
-installation or removal of architectural, sculptural or
vegetative screening that exceeds 3’ in height
-installation of accessory utility structures or
radio/satellite transmission/reception devices over 2’ in
diameter
•a change in exterior building color within a non-
residential zoning district
•a new, or change to an existing, sign or awning
•installation of telecommunications facilities
Note – Ordinary maintenance or repair that does not involve a change in material, design or outer appearance
is exempt from Historic or Architectural Review.
CITY OF SARATOGA SPRINGS
DESIGN REVIEW COMMISSION
City Hall - 474 Broadway
Saratoga Springs, New York 12866
Tel: 518-587-3550 x2533
www.saratoga-springs.org
4.DESIGN GUIDELINES:
The Design Review Commission will evaluate whether the proposed action (construction, alteration or
demolition) is compatible with existing structures and surrounding properties using the following criteria:
•Height – consistent with historic form and context of site and surrounding properties
•Scale – relationship of structure and its architectural elements to human size, form, perception
•Proportion – relationship among building elements including front façade, windows, and doors
•Rhythm – pattern resulting from repeating building elements such as door/window openings, columns,
arches, and other façade elements
•Directional Expression – compatibility with horizontal & vertical expression of surrounding structures
•Massing & Open Space – relationship of structure to open space between it and adjoining buildings
•Setback – compatibility with surrounding structures
•Compatibility of the following with surrounding structures/properties:
-Major building elements (storefronts, doors, windows, roof)
-Building materials
-Color – (in non-residential zoning districts only)
5.DECISIONS: The Design Review Commission may approve, approve with conditions, or disapprove an
application. The DRC may impose appropriate conditions and safeguards in connection with its approval
including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied
DRC application on the grounds of hardship.
Application approvals shall expire within 18 months of the filing date unless the project has sufficiently
commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may
request up to 2 extensions if requested before expiration date of prior approval.
6.AGENDA DATE: Check City’s website (www.saratoga-springs.org) for meeting dates. Applications are
placed on an agenda on first-come, first-served basis as determined by the completeness of the application.
7.APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance”.
REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT.
ADDITIONAL INFORMATION:
More detailed information on Architectural Review, Historic Review and the Design Review Commission
responsibilities may be found in the City’s Zoning Ordinance available in City Hall and on the City’s web site at
http://www.saratoga-springs.org/544/Zoning-Ordinance.
Revised 01/2021
OPED Fees Type
Application to Zoning Board of Appeals [1] [2]TOTAL #VARIANCE
Use Variance
Area Variance - Residential
Area Variance - Multi-Family, Comm, Mixed-Use
Interpretations
Post-Work Application Fee
Variance extensions
Application to Design Review Commission [1]TOTAL #STRUCTURE
Demolition
Residential Structures
Principal
Accessory
Extension
Modification
Multi-Family, Comm, Mixed-Use Structures
Sketch
Principal
Extension
Modification
Multi-Family, Comm, Mixed-Use Accessory, Signs, Awnings
Principal
Extension
Modification
Post-Work Application Fee
Application to Planning Board [1]TOTAL #STRUCTURE
Special Use Permit [2]
Special Use Permit - extension
Special Use Permit - modification [2]
Site Plan Review - incl. PUD:
Sketch Plan
Residential
Residential - extension
Residential - modification
Non-residential
Non-Residential - extension
Non-Residential - modification
Subdivision - incl. PUD: TOTAL #LOTS
Sketch Plan
Preliminary Approval [2]
Residential: 1-5 lots
Residential: 6-10 lots
Residential: 11-20 lots
Residential: 21+ lots
Residential - extension
Final Approval [2]
Residential
Non- Residential
Final Approval Modification [2]
Residential
Non- Residential
Final Approval Extension
Residential
Non- Residential
Other:TOTAL #LOT/ACRE
Post-Work Application Fee
Lot L ine Adjustment
Letter of Credit - m odification o r extension
Letter of Credit - c ollection
Recreation Fee
Land Disturbance
SEQRA EIS Review (Draft & Final)
Legal Noticing if PB requires Public Hearing
2021 Fee
$1100 + $50/app
$275/var + $50/app + $125 each add'l variance
$660/var + $50/app + $200 each add'l variance
$550 +$50/app
Add 50% App fee + $50/app
50% of App fee + $50/app
$385
$55
$55
$35
$55
$165
$550
$200
$330
$140
$75
$140
Add 50% App fee
$990 + $50/app
$330
$450 + $50/app
$330
$330 + $200/unit
$200
$400
$660 + $130/1000 sf
$300
$650
$330
$660 + $50/app
$990 + $50/app
$1320 + $50/app
$1650 + 50/app
$330
$1320 + $175/lot + $50/app
$2000/lot + $50/app
$330 + $50/app
$550 + $50/app
$135
$330
Add 50% App fee
$350
$440
up to 1% of LoC
$2000/lot or unit
$660 + $55/acre
TBD
$50/app
[1]Fees are based on per structure, except where noted.
[2]Legal ad required; includes City processing and publishing
__________Total Paid at Intake
__________Revised Fee
__________Balance Due
___/___/___Balance Paid Staff approval _______________
2021 LAND USE BOARD FEE WORKSHEET
For Administrative Use
TOTAL DUE
KITCHEN
104
DINING
105
EAT-IN
101
HALL
103
BATH
102
PORCH
100
LIVING
106
LIVING
107
UP
UP
UP
UPUPUPUPDW
RFRRANGE
BANQUETTE
NEW PORCH
MUD ROOM
KITCHEN
DINING
EAT-IN HALL
BTHRM
BENCHCOMPOST BIN RECESSED INTO
COUNTERTOP
UP
DN
UPUPPARLOR
LIVING ROOM
NEW PORCH SCALE: DATE: REVISIONS: A R C H I T E C T S 41 Long Alley Saratoga Springs, NY 12866 Phone: 518-584-7514 Fax: 518-584-7523A1.1STONE RESIDENCE167 Spring StreetSaratoga Springs, NY 12866EX. FIRST FLOOR PLANPROP. FIRST FLOOR PLAN1/4"=1'-0"5.1.231/4"=1'-0"
EXISTING FIRST FLOOR PLAN1
A1.1 1/4"=1'-0"
PROPOSED FIRST FLOOR PLAN2
A1.1
S: 22-3/8"
DN
CLOSET
ROOM
304
ROOM
303
ROOM
302
ROOM
301
ROOM
300
DN
ATTIC
304
BEDROOM
301
BATHROOM
302
ATTIC
303
ATTIC
305
SCALE: DATE: REVISIONS: A R C H I T E C T S 41 Long Alley Saratoga Springs, NY 12866 Phone: 518-584-7514 Fax: 518-584-7523A1.2STONE RESIDENCE167 Spring StreetSaratoga Springs, NY 12866EX. THIRD FLOOR PLANPROP. THIRD FLOOR PLAN1/4"=1'-0"5.1.231/4"=1'-0"
EXISTING THIRD FLOOR PLAN1
A1.2 1/4"=1'-0"
PROPOSED THIRD FLOOR PLAN2
A1.2
FIRST FLOOR
EL.=100'-0"
SECOND FLOOR
EL.=110'-1-7/8"
ATTIC FLOOR
EL.=119'-4"10'-178"9'-318"7'-738"ATTIC CEILING
EL.=126'-11-3/8"
FIRST FLOOR
EL.=100'-0"
SECOND FLOOR
EL.=110'-1-7/8"
ATTIC FLOOR
EL.=119'-4"10'-178"9'-318"7'-738"ATTIC CEILING
EL.=126'-11-3/8"
12" x 12" CEDAR POST WRAP
WOOD ENTABLATURE & FASCIA
MATCHED TO EXISTING
NEW STONE BASE MATCHED TO
EXISTING
5/4" x 10" CEDAR SKIRT
(2) NEW FLANKING DOUBLE-HUNG
WINDOWS MATCHED TO EX. (EXISTING
CENTER WINDOW TO REMAIN).
NEW CEDAR SHINGLES MATCHED TO
EXISTING EXPOSURE
5
4" x 5
4" CEDAR LATTICE
FIRST FLOOR
EL.=100'-0"
SECOND FLOOR
EL.=110'-1-7/8"
ATTIC FLOOR
EL.=119'-4"10'-178"9'-318"7'-738"ATTIC CEILING
EL.=126'-11-3/8"
FIRST FLOOR
EL.=100'-0"
SECOND FLOOR
EL.=110'-1-7/8"
ATTIC FLOOR
EL.=119'-4"10'-178"9'-318"7'-738"ATTIC CEILING
EL.=126'-11-3/8"
NEW PORCH NEW PORCHEXISTING RESIDENCE
(2) NEW KITCHEN WINDOWS
IN ORIGINAL LOCATION W/
HIGHER SILL SCALE: DATE: REVISIONS: A R C H I T E C T S 41 Long Alley Saratoga Springs, NY 12866 Phone: 518-584-7514 Fax: 518-584-7523A2.1STONE RESIDENCE167 Spring StreetSaratoga Springs, NY 12866EXISTING ELEVATIONSPROPOSED ELEVATIONS1/4"=1'-0"5.1.231/4"=1'-0"
PROPOSED SOUTH ELEVATION3
A2.1
1/4"=1'-0"
EXISTING SOUTH ELEVATION1
A2.1
1/4"=1'-0"
PROPOSED WEST ELEVATION4
A2.1
1/4"=1'-0"
EXISTING WEST ELEVATION2
A2.1
FIRST FLOOR
EL.=100'-0"
SECOND FLOOR
EL.=110'-1-7/8"
ATTIC FLOOR
EL.=119'-4"10'-178"9'-318"7'-738"ATTIC CEILING
EL.=126'-11-3/8"
FIRST FLOOR
EL.=100'-0"
SECOND FLOOR
EL.=110'-1-7/8"
ATTIC FLOOR
EL.=119'-4"10'-178"9'-318"7'-738"ATTIC CEILING
EL.=126'-11-3/8"
(2) NEW FLANKING ATTIC WINDOWS
MATCHED TO EX. (EXISTING CENTER
WINDOW TO REMAIN).
PAINTED T&G WOOD DECK
REINSTALL ORIGINAL EXTERIOR
DOOR IN NEW LOCATION
8" x 8" CEDAR POSTS PAINTED TO
MATCH EXISTING TRIM
WOOD ENTABLATURE & FASCIA
MATCHED TO EXISTING
NEW CEDAR SHINGLES MATCHED TO
EXISTING EXPOSURE
CLOSE TO CEILING SURFACE PORCH
LIGHT CONCEALED BEHIND
ENTABLATURE
NEW STONE BASE MATCHED TO
EXISTING
FIRST FLOOR
EL.=100'-0"
SECOND FLOOR
EL.=110'-1-7/8"
ATTIC FLOOR
EL.=119'-4"10'-178"9'-318"7'-738"ATTIC CEILING
EL.=126'-11-3/8"
FIRST FLOOR
EL.=100'-0"
SECOND FLOOR
EL.=110'-1-7/8"
ATTIC FLOOR
EL.=119'-4"10'-178"9'-318"7'-738"ATTIC CEILING
EL.=126'-11-3/8"
NEW PORCH NEW PORCHEXISTING RESIDENCE SCALE: DATE: REVISIONS: A R C H I T E C T S 41 Long Alley Saratoga Springs, NY 12866 Phone: 518-584-7514 Fax: 518-584-7523A2.2STONE RESIDENCE167 Spring StreetSaratoga Springs, NY 12866EXISTING ELEVATIONSPROPOSED ELEVATIONS1/4"=1'-0"5.1.231/4"=1'-0"
PROPOSED NORTH ELEVATION3
A2.1
1/4"=1'-0"
EXISTING NORTH ELEVATION1
A2.1
1/4"=1'-0"
PROPOSED EAST ELEVATION4
A2.1
1/4"=1'-0"
EXISTING EAST ELEVATION2
A2.1
FROST HURFF
A R C H I T E C T S
Street View from Southwest
Street View from Southeast
FROST HURFF
Front (South) Elevation
Rear (North Elevation)
FROST HURFF
Side (East) Elevation viewed from South
Side (West) Elevation viewed from South
FROST HURFF
Non-historical kitchen casement window to be removed. Note modern crank and sash lock.
Sandborn Map Showing Location of Original Porch