Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20230246 118 Woodlawn Social Club Plans
Woodlawn Club 118 Woodlawn Avenue Saratoga Springs, New York Design Review Commission Request For Final Approval Prepared by: Table Of Contents Page No. Description 1 Project Information Sheet Drawings 2 Existing Site Plan 3 Sanborn Fire Insurance Maps 4 Existing Photos 5 Neighboring Building Photos 6 Proposed Site Plan 7 Parking Lot Fence 8 Proposed First Floor Plan 9 Proposed Second Floor Plan 10 Proposed Basement Floor Plan 11 Existing South Elevation (Van Dam St.) 12 Existing West Elevation (Woodlawn Ave) 13 Existing North Elevation 14 Existing East Elevation 15 Proposed South Elevation (Van Dam St.) 16 Proposed West Elevation (Woodlawn Ave) 17 Proposed North Elevation 18 Proposed East Elevation 19 Proposed View from Van Dam St. (Day) 20 Proposed View from Van Dam St. (Night) 21 Proposed View from Woodlawn Ave (Day) 22 Proposed View from Woodlawn Ave (Night) Product Data 23-24 Stained Glass Narrative 25-29 Sussman Architectural Products Aluminum Church Windows 30-36 Marvin Windows and Doors 37-41 Ready-Slate Roof Tile 42 Exterior Paint Colors 43 Ornamental Railings 44-48 Architectural Louvers 49-53 Kitchen Hood Exhaust 54-65 Exterior Lighting Specifications Woodlawn Club 118 Woodlawn Avenue Saratoga Springs, New York Design Review Commission Request For Final Approval Prepared by: Project Information Sheet Applicant: EC Woodlawn Van Dam Property, LLC 118 Woodlawn Ave., Saratoga Springs, NY 12866 Architect: Balzer & Tuck Architecture PLLC Brett W. Balzer, AIA LEED AP, Partner Zone: UR-3 (Transect Zone 6: Urban Core) Project Address: 118 Woodlawn Avenue Saratoga Springs, NY 12866 Project Description: The project consists of a +- 9900 GSF two-story interior renovation which will serve as a future private/social club. The exterior scope of work includes renovating all existing non-compliant means of egress and replacing/restoring of existing windows. 0'10' 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Existing Site Plan NN 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Sanborn Fire Insurance Maps 1895 SANBORN MAP1895 SANBORN MAP1900 SANBORN MAP1900 SANBORN MAP 1950 SANBORN MAP1950 SANBORN MAP NN 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Existing Photos EXISTING PORCH at WEST ELEVATIONEXISTING PORCH at WEST ELEVATION WOODLAWN AVE looking at WEST ELEVATIONWOODLAWN AVE looking at WEST ELEVATIONVAN DAM ST looking at SOUTH ELEVATIONVAN DAM ST looking at SOUTH ELEVATION EXISTING STAIRS at EAST ELEVATIONEXISTING STAIRS at EAST ELEVATION WOODLAWN AVE looking at NORTH and WEST ELEVATIONWOODLAWN AVE looking at NORTH and WEST ELEVATION 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Neighboring Building Photos 122 WOODLAWN AVE122 WOODLAWN AVE 119 WOODLAWN AVE119 WOODLAWN AVE 17 VAN DAM ST17 VAN DAM ST115 WOODLAWN AVE115 WOODLAWN AVE 121 WOODLAWN AVE121 WOODLAWN AVE 20 VAN DAM ST20 VAN DAM ST BRICK BUILDING 10,050± SQ.FT. GFA CURBCURBCONCRETE S I D E W A L K GRAVELDRIVEWAYASPHALT 2 STORY WALKW A Y PAVERSCONC.CURB CURBCURB CURBSHEDSHEDSHE D W A L K W A YPORCHGRAVEL DRIVE W A Y EXISTING GRAVEL PARKING AREA EDGE OF PAVEMENTCONCRETE SIDEWALKCONCRETE SIDEWALKSITESIGN VAN DAM STREETWOODLAWN AVENUELONG ALLEYBOLSTER LANEN 24°00'00" ES 66°0 0 ' 0 0 " E S 24°00'00" WN 89°52'00" W N 66°4 7 ' 5 7 " WN 24°00'00" ES 66°4 7 ' 5 7 " E S 24°00'00" WN 66°4 7 ' 5 7 " WN 24°00'00" ES 66°4 7 ' 5 7 " E 130.00'N 24°00'00" ES 66°4 7 ' 5 7 " E S 24°00'00" W130.00'76.00'24.00'63.00' 63.00'24.00'67.00' 67.00'76.00'103.92'70.56'72.70'24.00'77.16' Property of JULIE A. MASSARONI TAX MAP NO. 165.51-2-15 LANDS N/F of EC WOODLAWN VAN DAM PROPERTY, LLC TAX MAP NO. 165.43-3-24 AREA = 0.23 ACRES 121-125 WOODLAWN AVE LANDS N/F of EC WOODLAWN VAN DAM PROPERTY, LLC TAX MAP NO. 165.51-2-11 AREA = 0.03 ACRES LANDS N/F of EC WOODLAWN VAN DAM PROPERTY, LLC TAX MAP NO. 165.51-2-13 AREA = 0.04 ACRES LANDS N/F of EC WOODLAWN VAN DAM PROPERTY, LLC TAX MAP NO. 165.51-2-14 AREA = 0.14 ACRES 118 WOODLAWN AVE Property of GAY L. FELLOWS ELIZABETH LYNN BENDAVID TAX MAP NO. 165.51-2-19 Property of G.S. & D.M. ZATKOVICH TAX MAP NO. 165.51-2-12 Property of GUY C. & BEVERLY C. MURPHY MURPHY FAMILY TRUST TAX MAP NO. 165.43-3-23 N 66°4 7 ' 5 7 " W PLAQUEWOOD FENCE 6.9'12.3'10.4'3.9' 3.9' EDGE OF G R A V E L 5.5'2.5'7.1'HYD344342340338 324328 326330332334336338 328330332334336 336 EXISTING BROADLEAF TREES ~20' O.C. TO REMAIN EXISTING GRAVEL LOT LIMITS LANDSCAPE BUFFER LINE FROM RESIDENTIAL USE PROPOSED GENERATOR WITH CONCRETE PAD EXISTING CONCRETE PAD TO BE REMOVED PROPOSED WORK AT 118 WOODLAWN AVE DESIGNED BY OTHERS EXISTING PORCH AND ROOF TO BE REPLACED IN KIND EXISTING RAILING TO BE REPLACED EXISTING RAILING TO BE REPLACED EXISTING STAIRS TO BE REPLACED & EXTENDED FOR CODE COMPLIANCE PER ZONING OFFICER EXISTING PAVERS TO BE REMOVED PROPOSED MECHANICAL EQUIPMENT AND CONCRETE PAD PROPOSED BROADLEAF TREES 30' O.C. 8' MIN. LANDSCAPE BUFFER ZONE LANDSCAPING TO BE PROVIDED PER UDO CODE 11.5 SECURITY FENCE W. LOCKED GATE (W. ACCESS CODE) DUMPSTER W. ENCLOSURE SHRUBS/LANDSCAPING TO BE PROVIDED PER UDO CODE 11.5 SHRUBS TO RUN LENGTH OF PARKING LOT FOR VISUAL BUFFER EXISTING SHEDS TO BE REMOVED, TYP.10'10'6'5' MECHANICAL SETBACK EXISTING SHEDS TO BE REMOVED, TYP.10'PROPOSED ASPHALT PARKING LOT REFER TO DETAIL 1/C-101 PEDESTRIAN LOCKED GATE (WITH ACCESS CODE) 5 5 6 6 22 SPACES TOTAL SECURITY FENCE LOCKED GATE 8' LANDSCAPE BUFFER ZONE 9'18'9' 9'24'10'10' 10'6'12' 13' LANDSCAPE BUFFER LINE FROM RESIDENTIAL USE EXISTING FENCE TO BE REMOVED PROPOSED BIKE RACK APPR.REVISIONS RECORD/DESCRIPTION 5 7 9 8 6 3 4 2 1 DATE DRAFTER CHECK :DRAFTED CHECKED PROJ. NO SCALE : DATE : : : UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW. C.T. MALE ASSOCIATES : c DWG. NO: SHEET OF PROJECT NUMBER: C.T. MALE ASSOCIATES Engineering, Surveying, Architecture, Landscape Architecture & Geology, D.P.C. 50 CENTURY HILL DRIVE, LATHAM, NY 12110 PH 518.786.7400 www.ctmale.com COBLESKILL, NY · GLENS FALLS, NY · POUGHKEEPSIE, NY JOHNSTOWN, NY · RED HOOK, NY · SYRACUSE, NY 23.3173 23.3173 23-0193 WOODLAWN CLUB118, 121-125 WOODLAWN AVE CITY OF SARATOGA SPRINGS SARATOGA, NEW YORK 2023 MARCH 30, 2023 1 FRANCIS G. PALUMBO R.L.A NO. 001226 XREFS:CAD DWG. FILE NAME:CAD DWG. FILE NAME:DESIGNED C-101_Woodlawn.dwgK:\Projects\233173\LD\Drawings-Maps\C-101_Woodlawn.dwgPROPOSED SITE PLAN MAC MAC FGP 1"=20' C-101 1 NONE BAR SCALE 1 inch = ft. 20 0 10 20 40 20 MAP REFERENCE: 1.“ALTA/NSPS LAND TITLE SURVEY, PREPARED FOR SARATOGA SPRINGS" PREPARED BY BOCK & CLARK CORPORATION A NV5 COMPANY, DATED JUNE 8, 2021 BEARING NETWORK PROJECT NUMBER 202102731-001. SITE PLAN NOTES: 1.APPLICANT: EC WOODLAWN VAN DAM PROPERTY, LLC 85 RAILROAD PLACE SARATOGA SPRINGS, NY 12866 2.PROJECT CONSISTS OF PARKING LOT IMPROVEMENTS ON PARCEL KNOWN AS 121-125 WOODLAWN AVE (TAX. MAP NO. 165.43-3-24). 3.PARKING LOT TO SERVICE PARCEL KNOWN AS 118 WOODLAWN AVE (TAX MAP NO. 165.51-2-14). 4.THE APPLICANT SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL LAWS, RULES AND REGULATIONS, INCLUDING BUT NOT LIMITED TO THE STATE ENVIROMENTAL QUALITY REVIEW ACT (SEQR). 5.TOPOGRAPHIC INFORMATION SHOWN HEREON IS PER LIDAR INFORMATION COLLECT IN 2012 AS SUPPLIED BY THE NEW YORK STATE GIS CLEARINGHOUSE, FEMA 2 METER DATA. 6.THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY AND SAFELY MAINTAINING CONSTRUCTION ACTIVITY WITHIN THE LIMITS OF THE CONSTRUCTION SITE. 7.DIG SAFELY NEW YORK (PHONE 800-962-7962 / PHONE 811 / WWW.DIGSAFELYNEWYORK.COM) SHALL BE NOTIFIED PRIOR TO CONDUCTING ANY TEST BORINGS, EXCAVATION OR CONSTRUCTION. UTILITY MARK-OUTS SHALL BE MAINTAINED THROUGHOUT THE CONSTRUCTION PERIOD. 8.PARCEL II OVERALL SIZE IS 0.23 ACRES AND IS LESS THAN THE MINIMUM REQUIRED 0.25 ACRES MINIMUM DISTURBANCE FOR THE BASIC SWPPP REQUIREMENTS UNDER THE UNIFIED DEVELOPMENT ORDINANCE ARTICLE 17. THEREFORE A SWPPP IS NOT REQUIRED FOR THIS PROPOSAL. 9.EXISTING SITE STORM DRAINAGE SHEET FLOWS WEST TO EAST TOWARDS WOODLAWN AVE AND SOUTHEAST ALONG WOODLAWN. THE PROPOSED PARKING LOT GRADING SHALL MATCH THE EXISTING TOPOGRAPHY OF THE SITE AND FOLLOW THE EXISTING SHEET RUNOFF FOR STORMWATER TOWARDS WOODLAWN AVE. 10.PLANTING SPECIES TO COMPLY WITH CITY OF SARATOGA SPRINGS UDO CODE SECTION 11.5. THIS WOULD INCLUDE ONE BROADLEAF TREE FOR EVERY 40 LF, FENCING AND SHRUBS WITHIN BUFFER AREA ABUTTING A STREET AND ONE BROADLEAF TREE FOR EVERY 30 LF AND SHRUBS WITHIN BUFFER AREA ABUTTING RESIDENTIAL SIDE YARD. 11.LIGHTING TO BE PROVIDED AS NECESSARY WITHIN THE PARKING LOT TO COMPLY WITH CITY OF SARATOGA SPRINGS UDO CODE SECTION 9.4. PLANS ARE FOR MUNICIPAL REVIEW ONLY NOT FOR CONSTRUCTION ZONING NOTES: 1.PARKING REQUIREMENTS PER UNIFIED DEVELOPMENT ORDINANCE ARTICLE 10. 2.LANDSCAPE REQUIREMENTS PER UNIFIED DEVELOPMENT ORDINANCE ARTICLE 11. 3.BUILDING SETBACK REQUIREMENTS NOT SHOWN, REFER TO CITY OF SARATOGA SPRINGS ZONING ORDINANCE. 4.NO OTHER ZONING DISTRICTS ARE LOCATED WITHIN 200' IN ANY DIRECTION OF THE PROJECT SITE. SITE STATISTICS ZONE: URBAN RESIDENTIAL-3 (UR-3) REQUIRED EXISTING PROPOSED LOT SIZE 6,600 SF 9,879± SF OR 0.23± ACRES 9,879± SF OR 0.23± ACRES PARKING REQUIREMENTS 1 SPACES PER 500SF GFA UNSTRIPED GRAVEL LOT BDG GFA: APPROX. 10,050 SF 21 SPACES REQ'D 22 SPACES PROPOSED LANDSCAPE BUFFER (RESIDENTIAL USES)10 FEET 0 FEET (NORTH) 2.5 FEET (SOUTH)10 FEET LANDSCAPE BUFFER (ABUTTING STREET)8 FEET 3.9 FEET 10 FEET SITE LOCATION MAP N.T.S. SOURCE: GOOGLE MAPS SCALE: CROSS REFERENCE: PARKIING LOT PAVEMENT SECTION NONE 1 C-101 NONE 4' - 0"4' - 0"26' - 0" DRIVE LANE 24' - 0"26' - 0" BLACK WROUGHT IRON FENCE BRICK WALL TO MATCH WOODLAWN CLUB CAST STONE CAP PARKING LOT ENTRY FENCE/ WALL (WOODLAWN AVE)PARKING LOT ENTRY FENCE/ WALL (WOODLAWN AVE) BLACK WROUGHT IRON SWINGING GATE 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Parking Lot Fence SIDE YARD BUFFER SHRUB - BOXWOOD SHRUBWROUGHT IRON FENCE DETAILS WROUGHT IRON FENCE GATE DN DN UP DN GASFIREPLACEREADINGREADING ROOMROOM BAR / DININGBAR / DINING VESTIBULEVESTIBULE ELEVATORELEVATOR BARBAR SEATS (10) KITCHENKITCHEN ADA LIFTADA LIFT ACCESSIBLEACCESSIBLE ENTRANCEENTRANCE WOMEN'SWOMEN'S RESTROOMRESTROOM MEN'SMEN'S RESTROOMRESTROOM MEZZANINE, ABOVE SEMI-PRIVATESEMI-PRIVATE LOUNGELOUNGE SEMI-PRIVATESEMI-PRIVATE LOUNGELOUNGE MEZZANINE, ABOVE SEMI-PRIVATESEMI-PRIVATE LOUNGELOUNGE SEMI-PRIVATESEMI-PRIVATE LOUNGELOUNGE COAT CL.COAT CL. COAT CL.COAT CL. STAIRSTAIR VESTIBULEVESTIBULE DN 0' - 0" -2' - 2" 0' - 0" 0' - 0"UP OUTLINE OF EXISTING ROOF OVERHANG ABOVE OUTLINE OF EXISTING STAIR DW OUTLINE OF EXISTING PORCH 0' 2' 4'8' 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Proposed First Floor Plan NN OPEN TO BELOW DINING LOFTDINING LOFT MEETINGMEETING ROOMROOM MEZZANINEMEZZANINE OPEN TO BELOW ELEVATORELEVATOR FIREPLACE, BELOW OPEN TO BELOW ATTICATTIC DN DN UP UNISEXUNISEX RESTROOMRESTROOM ADA UNISEXADA UNISEX RESTROOMRESTROOM VEST.VEST. VEST.VEST.CL.CL. VESTIBULEVESTIBULE VESTIBULEVESTIBULE MEETINGMEETING ROOMROOM MEETING RMMEETING RMFIREPLACEMEZZANINEMEZZANINE DW OUTLINE OF EXISTING ROOF OVERHANG ABOVE OUTLINE OF EXISTING PORCH 0' 2' 4'8' 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Proposed Second Floor Plan NN CRAWLCRAWL SPACESPACE (EXTG(EXTG BEDROCK)BEDROCK) CRAWLCRAWL SPACESPACE (EXTG(EXTG BEDROCK)BEDROCK) CORRIDORCORRIDOR STAIRSTAIR HALLHALL MECHANICALMECHANICAL ROOMROOM ELEVATORELEVATOR VESTIBULEVESTIBULE WINEWINE CELLARCELLAR ELEVATORELEVATOR STORAGESTORAGE 5' GROUND MOUNTED MECHANICAL EQUIPMENT INTERIOR SIDE SETBACK (SSUDO ARTICLE 9.5.O.1)(6'-8 1/2")6.70(5'-0")5.00PROPOSED MECHANICAL EQUIPMENT PROPOSED MECHANICAL EQUIPMENT UP DININGDINING 0' 2' 4'8' 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Proposed Basement Plan NN EXISTING BRICK EXISTING SLATE TILE ROOF EXISTING NON-COMPLIANT STAIRS EXISTING NON-COMPLIANT METAL PIPE HANDRAIL STAINED GLASS STAINED GLASS SG STAINED GLASS SG SG SG STAINED GLASS SG SG SGSG BOARDED BOARDED BOARDED EXISTING STAINED GLASS (SG) WINDOW, WHERE INDICATED EXISTING STONE STEPS EXISTING BOARDED WINDOWS, WHERE INDICATED 0' 2' 4'8' 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Existing South Elevation (Van Dam St.) EXISTING BRICK, TYP.EXISTING ASPHALT ROOF EXISTING ASPHALT ROOF EXISTING NON-COMPLIANT RAMP EXISTING CEDAR SHINGLE SIDING AND CORNER BOARDS EXISTING NON-COMPLIANT HANDRAIL, TYP. EXISTING SLATE TILE ROOF EXISTING METAL FINIAL EXISTING ASPHALT ROOF, TYP. EXISTING PORCH STAINED GLASS SG STAINED GLASS STAINED GLASS SG SG SG STAINED GLASS EXISTING STAINED GLASS WINDOW, WHERE INDICATED EXISTING STONE STEPS 0' 2' 4'8' 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Existing West Elevation (Woodlawn Ave) EXISTING BRICK, TYP. EXISTING ASPHALT TILE ROOF EXISTING VINYL WINDOW, WHERE INDICATED VINYL VINYLVINYL EXISTING BRACKET AND COVERED ENTRY EXISTING NON-COMPLIANT WOOD STAIRS AND RAILING EXISTING PORCH AND NON-COMPLIANT RAMP 0' 2' 4'8' 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Existing North Elevation EXISTING BRICK, TYP. EXISTING ASPHALT ROOF VINYL VINYLVINYL EXISTING BRACKET AND COVERED ENTRY EXISTING PTD PLYWOOD PANEL EXISTING DAMAGED EAVE EXISTING BOARDED WINDOWS, WHERE INDICATED SG SG STAINED GALSS SGSG STAINED GALSS STAINED GALSS BOARDED EXISTING VINYL WINDOW, WHERE INDICATED BD BD EXISTING CHIMNEY EXISTING NON-COMPLIANT WOOD STAIRS AND RAILING 0' 2' 4'8' 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Existing East Elevation EXISTING BRICK, CLEAN AND REPOINT AS REQUIRED NEW SLATE TILE ROOF, TYP. MECHANICAL EQUIPMENT, BEYOND STAINED GLASS STAINED GLASS SG STAINED GLASS SG SG SG STAINED GLASS SG SG SGSG NEW DECORATIVE METAL RAILING EXISTING WOOD DOOR TO BE RESTORED TO ORIGINAL FINISH AND STAIN EXISTING STONE STEPS EXISTING STAINED GLASS WINDOWS TO BE RESTORED NEW WINDOWS WHERE PREVIOUSLY BOARDED UP W/ PLYWOOD SILL LIGHT, E4, BLACK WALL MOUNTED LINEAR FIXTURE, E2, BLACK RECESSED FLOOR LIGHT FIXTURE CEILING MOUNTED LIGHT FIXTURE, E6, BRONZE HANDRAIL LIGHT RECESSED AT UNDERSIDE WALL MOUNTED LINEAR FIXTURE, E2A, BLACK LANDSCAPE LIGHT, E8, COPPER 0' 2' 4'8' 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Proposed South Elevation (Van Dam St.) EXISTING BRICK, CLEAN AND REPOINT AS REQUIRED NEW DECORATIVE METAL RAILING NEW SLATE TILE ROOF NEW SLATE TILE ROOF NEW COPPER METAL FLAT SEAM ROOF ABOVE PORCH NEW PANEL AND TRIM IN LIEU OF CEDAR SHINGLE SIDING 29" DECORATIVE WOOD RAILING, PTD NEW WOOD DECKING WALL MOUNTED LIGHT FIXTURE, ED1, BLACK EXISTING WOOD DOOR TO BE RESTORED TO ORIGINAL STAINED FINISH EXISTING STONE STEPS EXISTING STAINED GLASS WINDOWS TO BE RESTORED STAINED GLASS SG STAINED GLASS STAINED GLASS SG SG SG STAINED GLASS RECESSED LIGHTS IN WOOD SOFFIT, E5 WALL MOUNTED LINEAR FIXTURE, E1, BLACK SILL LIGHT, E4, BLACK WALL MOUNTED LINEAR FIXTURE, E2, BLACK RECESSED FLOOR LIGHT FIXTURE, E3 CEILING MOUNTED LIGHT FIXTURE, E6, BRONZE HANDRAIL LIGHT RECESSED AT UNDERSIDE NEW STAINED MAHOGANY WOOD DOOR EXISTING WINDOWS TO BE REPLACED NEW WOOD TRIM AND POSTS, PTD LANDSCAPE BOLLARD, E7, BLACK LANDSCAPE LIGHT, E8, COPPER 0' 2' 4'8' 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Proposed West Elevation (Woodlawn Ave) EXISTING BRICK, CLEAN AND REPOINT BRICK AS REQUIRED NEW SLATE TILE ROOF REMOVE EXISTING WINDOWS AND INFILL WITH RECESSED BRICK REMOVE EXISTING WINDOWS AND INFILL WITH RECESSED BRICK EXISTING WINDOWS TO BE REPLACED PROPOSED MECHANICAL EQUIPMENT NEW DECORATIVE METAL RAILING NEW STEEL STAIRCASE NEW COVERED ENTRY W/ BRACKET, PTD, WITHIN EXISTING NON-COMPLIANT FOOTPRINT NEW COPPER METAL FLAT SEAM ROOF ABOVE PORCH NEW COPPER METAL FLAT SEAM ROOF ABOVE PORCH NEW PANEL AND TRIM IN LIEU OF CEDAR SHINGLE SIDING 29" DECORATIVE WOOD RAILING, PTD EXISTING WINDOWS TO BE REPLACED NEW WOOD TRIM AND POSTS, PTD PROPOSED KITCHEN HOOD EXHAUST 0' 2' 4'8' 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Proposed North Elevation N O R T H E L E V A T I O NN O R T H E L E V A T I O N EXISTING BRICK, CLEAN AND REPOINT BRICK AS REQUIRED NEW SLATE TILE ROOF EXISTING DAMAGED EAVE TO BE RESTORED TO ORIGINAL PROFILE AND RETURN PROPOSED MECHANICAL EQUIPMENT PROPOSED MECHANICAL EQUIPMENT REMOVE EXISTING WINDOWS AND INFILL WITH RECESSED BRICK NEW DOOR TO BASEMENT, LOWERED TO PROVIDE ACCESS TO GRADE NEW SLATE TILE ROOF, TYP. NEW COVERED ENTRY W/ BRACKET, PTD, WITHIN EXISTING NON-COMPLIANT FOOTPRINT NEW DECORATIVE METAL RAILING SG SG STAINED GLASS SGSG STAINED GLASS STAINED GLASS EXISTING OPENINGS ENLARGED TALLER TO ALLOW FOR MEP VENTILATION RECESSED LIGHT AT SOFFIT, E5 WALL MOUNTED LIGHT FIXTURE, ED2 NEW STEEL STAIRCASE NEW COPPER METAL FLAT SEAM ROOF ABOVE PORCH WALL MOUNTED LIGHT FIXTURE, ED2 PROPOSED KITCHEN HOOD EXHAUST 0' 2' 4'8' 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Proposed East Elevation 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Proposed View from Van Dam St. (Day) 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Proposed View from Van Dam St. (Night) 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Proposed View from Woodlawn Ave (Day) 468 BROADWAY SARATOGA SPRINGS NY12866 P 518.580.8818F 518.580.8824BALZERTUCK.COM WOODLAWN CLUB BTA PROJECT NO: 2213 04.04.23 SARATOGA SPRINGS, NY Proposed View from Woodlawn Ave (Night) Woodlawn Club 118 Woodlawn Avenue Saratoga Springs, New York Design Review Commission Request For Final Approval Prepared by: Stained Glass Narrative General Condition of Stained Glass Windows: The (23) existing stained-glass windows at 118 Woodlawn Avenue are more than 100 years old and consist of American-made cathedral and opalescent glasses. The windows are constructed using lead came channel that was weatherproofed with linseed oil putty. The panels are supported with round steel reinforcing bars set into the wood frames and attached to the panels with copper wire ties. Approximately two thirds of the windows have older plexiglass protective glazing in place. The condition of the windows includes severely bulging glass, support bar ties which are detaching from the windows and lead came structure that has deteriorated. There are cracks visible in the came and at the solder joints. There is glass breakage in most of the panels. Some of the windows have been worked on over the years, but the work has been limited to repairs and maintenance as opposed to complete “in-studio” restoration. The caulking around the perimeter of the protective glazing has deteriorated and fallen off. The wood sashes holding the stained glass include deteriorated tenon joints and rotted sections. Description of the Restoration Process: Restoration will require the removal of the stained-glass window from the building to a glass restoration studio. The panels are photographed, removed from their existing wood frames and crated for transport. Measurements and templates are taken and the window opening is secured with plywood or other suitable covering. Unpainted glass that is missing or shattered and is not of a unique character will be replaced with new glass of a suitable match. The stained glass is proposed to be restored and reinstalled in a thermally broken aluminum frame specifically designed and fabricated to hold the stained-glass windows with a 1” insulated glass panel to the weather. The aluminum window frame contains an integral vent/weep cavity to promote the longevity of the newly reconstructed stained-glass windows, noting that the current bulging and failure of the stained glass is attributed to direct solar radiation and heat build-up in the window cavity between the stained glass and clear window glass. Woodlawn Club 118 Woodlawn Avenue Saratoga Springs, New York Design Review Commission Request For Final Approval Prepared by: Stained Glass Restoration Consultant: Chapman Stained Glass Studio Ballston Spa, NY https://www.chapmanstainedglass.com/ Chapman Stained Glass Studio, Inc. has been creating and installing ecclesiastical and secular leaded glass for 120 years. Continuously in operation since 1898, Chapman Studio has earned a trusted name in the field, specializing in the repair and restoration of antique and historical stained glass. Stained Glass Window Frame Replacement: Sussman Architectural Products LLC Jamaica, NY https://sussmanarchitectural.com/windows/church-windows/ Family owned and run since 1906, Sussman Architectural Products LLC is the oldest and largest manufacturer of custom windows and special aluminum extrusions for the stained and leaded art glass trade. They have the industry’s largest selection of specialized church window systems (for stained and/or protection glass) with over 100 years of experience and many thousands of successful installations worldwide. The proposed Sussman Architectural Products LLC aluminum extruded church window frames are specially designed to receive both stained glass and protective glass in the same frame. Besides protection from vandalism and natural causes these church window systems provide enhanced insulation from the sound, heat and cold, and can substantially lower fuel costs and conserve energy. As noted above, the aluminum window frame contains an integral vent/weep cavity to promote the longevity of the newly reconstructed stained-glass windows, noting that the current bulging of stained glass is attributed to direct solar radiation and heat build-up in the window cavity between the stained glass and clear window glass. 08 51 00/SUS Since 1906 America's Finest Custom Aluminum Windows for Churches, Chapels, Synagogues, BuyLine 0888 Memorial Buildings, Schools, Hotels, Office Buildings, Libraries, Restaurants,etc. MANUFACTURERS OF AMERICA'S FINEST ARCHITECTURAL METAL PRODUCTS AND SERVICES www.jsussmaninc.com J. SUSSMAN, INC. 6400 Series -312" Deep (replaces 5600 Series) Triple Glazed Thermal Church Windows for Stained and Insulated Protective Glass (Interior Exterior) J. SUSSMAN, INC. 2 Cover Photos: 1 2 5 4 3 See us on the internet www.jsussmaninc.com Our in-house Thermal Strip system gives us Dual Color finishing capability./ With an ever-increasing emphasis on color and aesthetics in the construction industry, J. Sussman, Inc.has developed two new window systems to help meet this demand. J. Sussman, Inc.now has the in house ability to produce windows with different colors and finishes to the exterior and interior.This is done with the use of Thermal Strip©technology.Two different aluminum extrusions can be finished independent of each other and then joined together with two 6/6 polyamide nylon thermal strips.Besides being thermally efficient, these high strength strips have the same coefficient of expansion as aluminum so that dry shrinkage is eliminated and the structural integrity of the window is intact. The result is a stronger thermally improved window with capability of different colors and finishes inside and out. Main frame and sash members are a full 312" deep with double tubular ventilators, frame, muntins and meeting rails. Triple glazed thermal barrier design that can accommodate 1" protective insulated glass with another 5/8"airspace between the art glass insulates the cold outside temperatures from the warmer inside temperature and helps eliminate condensation and noise infiltration.Insurance costs can be substantially lower as a result. The separation of art and protective glass is achieved by a channel that is an integral part of the extrusion.(Not an add on piece.)This channel acts as a condensation gutter and helps prevent air and water infiltration. Separate glazing beads allow either glass to be installed without disturbing the other.Protective glass can be installed at time of erection and art glass can be installed at the owner's convenience.(Stained glass can be an excellent fund raiser) Ventilators have 3 rows of continuous weatherstripping. Windows can also accommodate interior faceted glass and an exterior protective glass or 14" protective glass and stained glass. Special Feature:Large sections of insulated glass can be installed on the exterior and for the art glass special narrow siteline muntins can be placed in the interior of the frame in virtually any shape or size to suit the design and help keep costs down.(These interior muntins can also be installed at a later date to fit the design.) J. Sussman, Inc.has the largest selection of systems specifically designed for church windows providing the best product in the right price range to suit every budget. J. Sussman, Inc.windows can be produced in virtually any shape or size, with or without thermal breaks and with true muntins.They can be con- figured with combinations of fixed, projected and casements.Our 300 Series is even available with the historical church window standard,the Horizontally Center Pivoted ventilator. 1 1. St. Thomas Moore Church St John's University, Queens NY Rohlf's Stained Glass, Mt. Vernon NY Architect: Martin A. DeSapio, AIA Photo: Taylor Photo 2. St Martin's Episcopal Church Houston TX Willet Hauser Architectural Glass, Winona MN Glazing Contractor: Admiral Glass, Houston TX Jackson & Ryan Architects, Houston TX 3. St Lawrence Church Cincinnati OH Harmon Inc., Cincinnati OH Thomas Gormley GBBN Architects, Cincinnati, OH 45202 BeauVerre/Riordan Studios, Middletown OH Photo courtesy of The Catholic Telegraph 4. Foster Family Chapel at Congregation Beth Israel, San Diego CA Discount Glass, San Diego CA Austin Veum Robbins Parshalle, Architects Photos: Stuart Simmons 5. Southwestern Baptist Theological Seminary Convention Center, Ft. Worth TX Foster Stained Glass, Bryan TX Yeshiva of Spring Valley, Spring Valley NY Glazing Contractor: Ailamos, Bronx NY Minimum 5 8" air space 18"thick walls 312" Weeped channel allows for positive drainage of insulated glass Separate glazing beads allow either glass to be installed without disturbing the other Interior stained glass 1" exterior protection glass Glass is separated by a channel that is an integral part of the extrusion (not applied) 6/6 polyamide nylon thermal strip (Placed under glass where it is most effective) Since 1906 4200 Series -212" Deep 2400 Series -2" Deep J. SUSSMAN, INC. CUSTOM WINDOWS 300 Series -212" Deep 3200 Series -21 4" Deep3600 Series -21 4" Deep 200X Series -15 8" Deep 4800 Series Double Glazed Custom Church Windows Custom Thermal Windows Non-Thermal Custom WindowsMonumental Non-Thermal Windows Monumental Custom Thermal Windows for Stained and Protective Glass Dual Thermal Windows Thermal Terrace Doors Color (Interior (Interior Exterior) Exterior) J. SUSSMAN, INC. 3 BuyLine 0888 J. Sussman, Inc.'s other services and products include Custom Glass and Metal Bending, Skylights, Walkways, and Sunbilt Sunrooms. For more information see us on the internet at www.jsussmaninc.com 08 51 00/SUS Full 2 1/2" deep frame with double tubular sash, muntins and intermediate rails. (Consult factory for full specifications) Thermal Strip technology for added strength and Dual Color finishing capability. All corners are fastened on each side of the thermal break. Sash corners are mitered, heavy angle reinforced and hydraulically crimped and epoxy welded. Flush design eliminates dust shelves and water traps and helps create a clean, neat appearance. Full 2 1/2" deep tubular frame and door sash Thermal Strip technology for added strength and Dual Color finishing capability. Door corners are mitered, heavy angle reinforced, epoxy welded and hydraulically crimped. Flush design eliminates dust shelves and helps create a clean, neat appearance. Multi-point locking system with three way adjustable hinges. One piece extrusion with poured in place structural polyurethane thermal barrier placed closest to exterior will insulate best and help eliminate condensation. One piece extrusion with poured in place structural polyurethane thermal barrier placed closest to exterior will insulate best and help eliminate condensation. / / Full 2" deep frame with 1/8" walls and tubular sash will meet and/or exceed AAMA HC-65 and GS-001 monumental performance specifications. All corners are either fully welded or heavy angle reinforced, epoxy welded and hydraulically crimped. Flush design eliminates dust shelves and water traps and helps create a clean, neat appearance. Windows can accept up to 1" thick insulated glass or slab glass (dalle de verre). Full 1 5/8" deep frame with tubular sash will meet and/or exceed AAMA C-50 commercial performance specifications. Metal strategically placed to give maximum strength. All muntins and intermediate rails are tubular. Flush design eliminates dust shelves and helps create a clean, neat appearance. Full 2 1/4" deep frame with 1/8" walls and tubular sash will meet and/or exceed AAMA HC-65 and GS-001 monumental performance specifications. All muntins and intermediate rails are tubular. Flush design eliminates dust shelves and water traps and helps create a clean, neat appearance. Full 2 1/4" deep frame with tubular sash will meet and/or exceed AAMA HC-65 and GS-001 monumental performance specifications. Metal strategically placed to give maximum strength. All muntins and intermediate rails are tubular. Flush design eliminates dust shelves and water traps and helps create a clean, neat appearance. 2 1/2" Deep Designed to recieve protection glass on the exterior and art glass on the interior with a minimum 3/4" air space in between. Either glass can be installed or replaced without disturbing the other. Glass is separated by a channel that is an integral part of the extrusion and also acts as a condensation gutter. Narrow sightlines to maximize the exposure of art glass. Immaculate Heart of Mary Catholic Church Grand Junction, CO Bratton Window and Door, Grand Junction CO Slater-Paul & Associates, Denver, CO 3 4" 212" 214"2 14" 15 8" 2" 212" Since 1906 Installations and thousands more. . . J. SUSSMAN, INC. Since 1906 109-10 180th Street, Jamaica, New York 11433 Tel: 718-297-0228 Fax: 718-297-3090 Printed in U.S.A. Copyright 2008 J.Sussman, Inc. MANUFACTURERS OF AMERICA'S FINEST ARCHITECTURAL METAL PRODUCTS AND SERVICES J. Sussman, Inc. manufactures windows for renovation work in standard as well as landmark buildings.In addition, from St. Patrick's Cathedral in New York City to The Most Holy Mother of God Parish in Vladivostock, Russia there are many thousands of specialized Sussman church windows installed throughout the world. St. Ann's Parish Church, Kaneohe, HI Fuller Glass Co., Inc.,Honolulu, HI Architect: Matsushita and Associates St. Bridget of Ireland, Berryville, VA Roy's Glass Service, Inc., Kearneysville, WV Architect: Balzer and Associates White's Chapel United Methodist Church, Southlake, TX DGB Glass Inc., Aledo, TX Architect: Hesson Andrews Sotomeyer Sprinkle/Robey The Salvation Army, Brooklyn Park, MN United Glass Inc., Roseville, MN Architect: Timothy O'Brien and Associates Architects St. Mary's Church, Huntley, IL Century Art Glass Co., St. Louis, MO Architect: Charles E. Pease St. Martin's Episcopal Church, Houston, TX Admiral Glass, Houston, TX Willet Hauser Architectural Glass, Winona MN New Chapel for Dominican Sisters, Fair Lawn, NJ Midway Glass and Metal Installers, Inc., Fair Lawn, NJ Architect: Martin Holub Architects and Planners Immaculate Conception Parish, Pittsburgh, PA Hunt Studios, Pittsburgh, PA Architect: Belli & Belli St. Thomas Moore Church, Lake Ariel, PA Mesko Glass Co., East Stroudsburg, PA Architect: V.S.Riggi A.I.A. Ward Presbyterian Church, Northville, MI Huron Valley Glass, Ypsilanti, MI Architect: Lindhout Associates A.I.A. P.C. St. Thomas A. Becket Church, Eugene, OR Beyer Stained Glass, Philadelphia, PA Congregation Beth Israel, San Diego, CA Discount Glass & Mirror, San Diego, CA Architect: Austin Veum Robbins Parshalle Catholic Church of Christ The King, Singapore Derix Art Glass , Oakland, CA Designer: John Calligan St. Elizabeth Annseton Chapel, Whiting, NJ Hiemer & Co., Clifton, NJ Architect: Mlloy, Duffe, and Foran Holy Family Catholic Church, Port St. Lucie, FL Chauncey's Glass Co., Fort Pierce, FL Architect: Moreu and Associates P.A. St. Joseph's Church, Marksville, LA Mobile Glass Service, Inc., Marksville, LA Architect: Weimer and Boudreaux Architects St. Killian's Parish, Farmingdale, NY Durhan Studios, West Hempstead, NY Architect: Ira Haspel, Architects, P.C. Seventh Day Adventist Church, Berrien Springs, MI Midwest Glass & Mirror, Stevensville, MI Architect: Helard and Helard Architects United Methodist Church, Genera, IL Franklin Glass, Glendale Heights, IL Architect: Cone-Kalb-Wonderlick Upton Baptist Church, Upton, KY Peter K. Eichorn Stained Glass, Louisville, KY Architect: George Torello All Saint's Church, Knoxville, TN Holston Glass Co., Kingsport, TN Architect: G.C. Blaine Construction St. Catherine's House, Charleston, MA Burnham and Laroche Associates, Medford, MA Architect: Kevin M. Bryan Specifications Subject to Change Without Notice www.jsussmaninc.com Intermountain Glass, Salt Lake City, UT Architect: Beyer, Blinder, Belle Cathedral of the Madeline, Salt Lake City, UT The following is a partial list of recent installations. For further assistance Call, Write, Fax or E-mail us. Architect: Jackson and Ryan Architects Sam Nunn Federal Center, Atlanta, GA Quaking Aspen Stained Glass, Porter, ME First United Methodist Church, Fort Payne, AL Groat Construction Company, Inc., Fort Payne, AL Architect:Alan L. Williamson Saint Kathryn's Church, Hudson, NH Saint Michel Liturgical Arts, Inc., Norwood, MA Architect: Keefe Associates, Inc. Architects Beth Shalom Congregation, Rockville, MD Rure Associates, Middlesex, NJ Architect: Levin/Brown and Associates Inc. St. Augustine Church, Barberton OH Conrad Schmitt Studios, New Berlin, WI Architect: Zita Smith Family Court, Philadelphia PA Keystone Aluminum and Glass Co., Penndel, PA Architect: Murphy Quigley Co., Inc St. Boniface Church, Lidgerwood, ND Glass Unlimited Inc., Fargo, ND Architect: Curtis Construction Mary Queen of the Universe Shrine, Orlando, FL Rogers, Lovelock and Fritz, Inc., Winter Park, FL Architect: Jack Rogers of R.L.F. Architects Inc. St. Thomas Moore Church St. John's University, Queens NY Rohlf's Stained Glass Architect: Martin A. DeSapio, AIA Our Lady of Sorrows C.C., Victoria, TX Mitchell Glass Co., Victoria, TX Architect: Rawley McCoy and Associates Grace Lutheran Church, New Orleans, LA City Glass and Mirror Co., New Orleans, LA Architect: The Mathes Group St. Gregory the Great, Seward, NE Builders Inc., Lincoln, NE Architect: Sinclair Hille and Associates Inc. Madison St. United Methodist Church, Clarksville, TN Wall Bros. Glass, Inc., Clarksville, TN Architect: Everton, Oglesby, Askew Architects Ascension of Our Lord Catholic Church, Laplace, LA Southern Wall and Windows, New Orleans, LA Architect: Blitch/Knevel Architects The Cathedral of St. Mary, Lafayette, IN Kaleidoscope Stained Glass, Inc., Lafayette, IN Architect: Scholer Corporation Episcopal Church of the Nativity, Dothan, AL Dothan Glass Company, Dothan, AL Architect: Barganier, Davis, Sims St. Joseph Parish, Cottleville, MO Missouri Valley Glass Co., St. Charles, MO Architect: LePique and Orne Architects Mid City Church, Midland, TX Foster Stained Glass, Bryan, TX Architect: Heath Aikan First United Methodist Church, Oklahoma City, OK Karen Hendrix and Associates, Oklahoma City, OK Lake Magdalene United Methodist Church, Tampa, FL Precise Construction, Inc., Tampa, FL Architect: R.B.K. Architect Inc. Isolated water pocket allows for positive drainage and keeps water away from IG unit Sus-filler tape breathes Weeping the exterior insulated glass to prevent glass failure. The greatest cause of insulated glass failure is the seal around the glass breaking down. This is usually caused by water coming in direct contact with the seal. Water is the enemy of the seal and the seal will deteriorate without proper weepage.Insulated glass manufacturers will not warranty their glass if water is not weeped away from the glass. The 6400 Series church window features an isolated water pocket away from the glass to prevent the insulated glass from sitting in water. The system allows positive weepage away from the glass to the exterior. Venting to reduce condensation and heat buildup. Condensation and heat buildup between the protective glass and the stained glass can deteriorate the stained glass. There are many ways to combat condensation and heat buildup in a church window. The 6400 Series church window with insulated glass and its thermal break frame will be adequate in most cases. Due to variables such as location, altitude, climate, humidity and orientation to the sun some conditions will require additional measures. For more extreme conditions J. Sussman recommends the following options: Using SUS-FILLER tape to glaze the interior stained glass. SUS-FILLER is a single sided self adhesive open cell foam tape. It is used instead of caulking or glazing tape and allows the air space between the glasses to breathe yet will filter out dust, dirt and insects. The glass is dry set which makes for a simple, fast, clean and economical installation. Using high performance glass such as glass with a low-emittance (low-E) coating is an excellent way to reduce heat buildup between the glasses and condensation. Low-E glass coatings reduce solar heat gain while retaining high visible transmittance. Air conditioning and heating costs will be further reduced by using high performance protective glass. Venting within the window can be achieved by strategically placing special ventilation slots in the frame and glazing beads. Slots at the top and bottom allow air to circulate by natural convection. This cools off the airspace and helps eliminate condensation. The tubular profiles in the 6400 church window prevent dirt and dust around the perimeter from infiltrating the air space. WEEPING AND VENTING 6400 Series TRIPLE GLAZED THERMAL BREAK CHURCH WINDOWS America's finest custom windowsSince 1906 J. Sussman, Inc. 109-10 180 St.Jamaica, NY 11433 Tel: 718-297-0228 Fax: 718-297-3090 www.jsussmaninc.com Rev. 11/10 6400-1B Air circulates through airspace either from slotted and screened glazing bead or screened dust covers in frame depending on conditions Tubular profiles prevent dust, dirt and insects from infiltrating air space Insulated glass with low-e coating helps prevent heat buildup and condensation CATALOG ULTIMATE DOUBLE HUNG G2 The Ultimate Double Hung G2 window is an embodiment of our dedication to the craft of creating windows and doors. Influenced by the rich, historical significance of this window style and inspired by innovative design, each feature is thoughtfully added and every detail is carefully considered. This is all in service of shaping a window that deserves to be in the unique homes our customers desire. INTERIOR EXTERIOR UNIQUE WASH MODE ALLOWS CLEANING OF BOTH SIDES OF GLASS FROM INDOORS Double Hung G2 windows in White with Oil Rubbed Bronze hardwarePhoto: Laurey W. Glenn Double Hung G2 window in White with Oil Rubbed Bronze hardware ULTIMATE DOUBLE HUNG G2 15 MARVIN® 14 MARVIN SIGNATURE® COLLECTION SUPERIOR WEATHER PERFORMANCE LC-PG50 on most sizes. Optional commercial (CW) performance and IZ3 certified coastal performance on most sizes. DESIGN VERSATILITY An array of simulated divided lite patterns, interior and exterior color options, ten hardware finishes, and archtop models. ALUMINUM INTER-LOCK Eliminates drafts and improves the window’s overall structural integrity. TRADITIONAL SILL BEVEL The 14-degree bevel provides optimal water management while maintaining a classic look. DURABLE CLADDING Extruded aluminum exterior cladding with an AAMA verified 2605 finish and backed by a 20-year warranty against chalking and fading. EXPANSIVE SIZES Larger than 5 feet wide by 10 feet high. EXTERIOR FEATURES AND PERFORMANCEINTERIOR FEATURES AND PERFORMANCE RICH WOOD INTERIOR Offers beauty and warmth with six wood species and ten interior finish options. ULTIMATE DOUBLE HUNG G2 Engineered for performance and designed to inspire, each aspect of the Ultimate Double Hung G2 window was made with purpose. Our engineers consider every detail from the most innovative features to the most minute subtleties, all because the windows in your home help illuminate the most important parts of your life. NARROW CHECKRAIL Provides a sleek aesthetic at 1 15/16 inches to maximize daylight opening while maintaining historical accuracy. FIRST-RATE ENERGY EFFICIENCY Meets ENERGY STAR ® standards in energy efficiency with multiple glass options for various regions, climates, and weather needs. TILT WASH MODE Allows easy access to exterior glass for cleaning and maintenance. EXCLUSIVE AUTOLOCK Activates when the sashes are closed, locking the window. SASH BALANCE SYSTEMS Enables smooth operation at the largest sizes. 16 MARVIN SIGNATURE® COLLECTION 17 MARVIN® ULTIMATE DOUBLE HUNG ROUND TOP G2 The Ultimate Double Hung Round Top G2 window will add traditional arching and elegant lines to your home or historic preservation project. With the same features and grace of the Ultimate Double Hung G2 window, this window offers design flexibility with numerous variations of radius shapes. Choose from multiple divided lite patterns to further enhance the arch of the window. These versatile windows–available in a wide range of sizes–can provide a subtle accent or a dramatic focal point to enhance your home design. EYEBROW RADIUS HALF CIRCLE TRANSOM EYEBROW TRANSOM HALF CIRCLE RADIUS HALF EYEBROW ROUND TOP VARIATIONS EYEBROW AND HALF EYEBROW RADIUS OPERATING DOUBLE HUNG A classic look with a gentle eyebrow radius. Beautiful as a stand alone window or as part of an assembly. HALF CIRCLE TRANSOM This simulated half circle transom window can be sized to stand alone or easily fit above a double hung window. EYEBROW TRANSOM AND PICTURE This stationary window is available as a transom or picture window. These windows are designed to complement the Ultimate Double Hung G2 window with correlating sizes and matching springline. HALF CIRCLE RADIUS OPERATING DOUBLE HUNG A dramatic window with a true half circle arch. The look gives a beautifully smooth transition from jamb to header. Both sashes are operable. ASYMMETRIC CURVE OPERATING SINGLE HUNG This striking window style adds elegant curve to a two-wide window assembly (not shown). Double Hung Round Top G2 windows in White with Satin Nickel hardware ULTIMATE DOUBLE HUNG ROUND TOP G2 19 MARVIN® 18 MARVIN SIGNATURE® COLLECTION DOORS Multi-Slide doors in Bronze 64 65 MARVIN® MARVIN SIGNATURE® COLLECTION ULTIMATE COMMERCIAL DOOR Commercial door INTERIOR EXTERIOR PANIC RIM, CLOSER, REMOVABLE MULLION, AND SILL OPTIONS ULTIMATE COMMERCIAL DOOR The Ultimate Commercial door combines sophisticated design with the rugged durability to stand up to years of commercial use. Available in a wide variety of design and customization options, they’re manufactured with different construction and assembly processes from our residential doors. Commercial door 85 MARVIN® 84 MARVIN SIGNATURE® COLLECTION PINE WESTERN RED CEDAR Exterior trim package only VERTICAL GRAIN DOUGLAS FIR MAHOGANY WOOD Wood is a premium material for windows and doors, offering classic aesthetic appeal, many options for customization, and design versatility. We treat exposed millwork with a water repellent wood preservative to help it last longer. Choose from one of the four options below. Each is ready to be finished to match your project’s exacting requirements. EXTRUDED ALUMINUM Extruded aluminum is an extremely tough cladding that protects wood windows, mimics the profiles of wood, and provides superior durability. It is the most commonly ordered exterior material for our Ultimate products. Select a color from our palette of 19 durable extruded aluminum colors, including a spectrum of rich hues and three pearlescent finishes. If you have more specialized needs, we can also work with you to create a custom color. Double Hung G2 window in Ebony Double Hung G2 window in Suede STONE WHITE SIERRA WHITE COCONUT CREAM CASHMERE PEBBLE GRAY HAMPTON SAGE CADET GRAY CLAY CASCADE BLUE SUEDE BAHAMA BROWN EVERGREEN EBONY COPPER (PEARLESCENT) LIBERTY BRONZE (PEARLESCENT) CUSTOM COLOR: ANY COLOR YOU WANT BRONZE WINEBERRY GUNMETAL EXTERIOR FINISH OPTIONS BRIGHT SILVER (PEARLESCENT) 90 MARVIN SIGNATURE® COLLECTION 91 MARVIN® min. free area = Step #3: Compare specified performance to the certified recommended free area velocity. From the free area table above the approximate Max. Recommended Velocity 1250 =15000 12 sq ftarea table, that meets the minimum free area requirement. To determine minimum free area required for louver: Step #1: Divide the required CFM flow by the maximum louver shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and American Warming and Ventilating certifies that the model LE-32 accordance with AMCA Publication 511 and comply with the LE-31 Form No. AWVLE31 February 2017 louver size is 48'' x 60'' = (12 sq ft)water penetration and pressure drop ratings. Given: 15000 CFM design flow Design CFM Example: Step #1: Step #2: Step #2: Select the most desirable louver size, from the free = 3.357 3.868 2000 (5.0) (2.5)0.01 200 2438 1.93 0.179 7.60 0.706 13.27 1.233 96 FREE AREA IN SQUARE FEET (sq meters) 41.63 1.760 2.287 30.29 2.814 3.341 2.441 18.94 31.20 24.62 16.44 1.527 21.36 1.984 26.28 35.96 6.60 0.613 11.52 1.070 84 2134 1.67 0.155 26.45 2.457 1.062 30.62 2.070 18.11 1.682 22.28 1.380 18.27 9.76 0.907 13.93 1.295 0.108 1.886 20.30 1.697 21.69 2.015 1.372 17.53 14.8512.00 1.115 14.77 0.625 0.345 11.43 0.858 0.426 8.01 0.744 9.24 0.255 0.628 8.02 2.75 24 610 0.43 0.040 3.27 0.393 5.49 : 0.01 oz (3.0 g) at 1250 fpm (6.35 m/s) recommended free area velocity : 0.21 in wg (52 Pa.) at 1250 fpm (6.35 m/s) and 11550 scfm (5.45 scm/s) : 9.24 sq ft (0.858 sq m) = 57.8% for 48'' x 48'' (1.22m x 1.22m) test size INTAKE PRESSURE DROP in. w.g. (Pa)(17.4)0.07 84 8.75 0.275 0.69 4.72 0.439 6.73 1.70 0.1580.064 1.21 0.112 0.208 1.72 0.160 HEIGHT60 1524 72 914 WIDTH 1829 0.251 48 305 0.18 0.017 0.087 0.510 6.76 Water Penetration Pressure Drop Free Area 4.23 5.59 0.519 12 6.47 0.601 60 1524 1.16 48 1219 0.94 72 1829 1.42 0.132 4.59 1219 24 610 36 3.712.70 2.96 in. mm 12 305 36 914 0.69 0.064 0.813 25.12 2.334 1.187 14.79 1.374 10.76 1.000 12.78 1.629 2.24 (15.3) 0.745 9.29 0.863 (45.7) WATER PENETRATION 2.845 36.13 2.8990.304 3.78 0.3512438 Openings that require multiple louver panels in both width and height will require internal structural supports. It is recommended that large openings be divided with structural members so that the louvers will span either width or height with a single panel. Unusually high wind loading may require structural supports on non-multiple wide and multiple high assemblies. Structural supports and mounting accessories are not supplied as a standard.data for the recommended free area velocity of 1250 fpm (6.35 m/s). Below is an explanation of how to use the AMCA Performance Certified Ratings Seal applies to air performance ratings and water 0.02 1 10000 (50.8) VELOCITY THROUGH FREE AREA fpm (m/s) (10.2) (61.0) (91.5) (76.3) 2134 96 (248) (30.5) (174)0.7 (124)0.5 (74.4)0.3 0.05(12.4) AMCA Figure 5.5 Test Setup (1.0)(2.0) 400 (49.6)0.2 (24.8)0.1 (7.4)0.03 1000 (5.1) VELOCITY THROUGH FREE AREA fpm (m/s) Airflow at standard air density - .075 lbs per cu ft Ratings do not include the effect of a wire bird screen Test based on a 48" x 48" test size per AMCA Standard 511 Both maximum recommended free area velocity and beginning of test size per AMCA Standard 511. The above water penetration data is based on mill finish, 48" x 48" water penetration are 1250 fpm at standard air -.075 lbs per cu ft. penetration ratings. procedures performed in requirements of the AMCA Certified Ratings Program. The AMCA 0 0.05 0.1 0.15 0.2 0.25 0.3 500 600 700 800 900 1000 1100 1200 1300oz per sq ft(grams/m2)FREE AREA (15 min duration)(2.5)(3.0)(3.5)(4.0)(4.5)(5.0)(5.5)(6.0)(6.5) Less than 0.01 oz./sq. ft .AMCA Standards are based on maximum of 1250 fpm free area velocity and a min of 0.01 oz/sqft free area of water penetration. The AMCA test was unable to determine the beginning water penetration due to the fact that is lies above 1250 fpm through free area. STANDARD FINISHES American Warming and Ventilating’s (AWV) comprehensive line of louvers are provided in mill, anodized, Kynar® (aka PVDF) and other special finishes. AWV is a licensed applicator for Valspar and meets AAMA painting (2603, 2604 & 2605) specifications. AWV’s 25 standard colors on this chart depict the most popular colors in today’s architectural, commercial and industrial markets. Fluropon®* should be specified when superior resistance to color fading and chalking is essential. Factory applied and oven cured, Fluropon is made with 70% PVDF (Kynar 500® or Hylar 5000®) resins and durable ceramic pigments. Fluropon is unsurpassed in its resistance to the damaging UV rays of the sun. It is resistant to general air pollution and it will not whiten or pit when exposed to moist environments such as rain, dew, fog, salt air and acid rain. Actual Florida exposure studies show that Fluropon, made with 70% PVDF resin, far surpasses all other types of coatings for long life with good looks. Fluropon meets or exceeds AAMA 2605 (American Architectural Manufacturers Association) specifications. CUSTOM FINISHES Fluropon is available in a wide range of colors. Special color matching can be provided by our in-house computerized paint color formulating system in our Bradner, OH facility. Simply submit a color chip for analysis and AWV will formulate a match for your custom color. OTHER COATINGS & FINISHES Fluoropolymer coatings in metallic, pearlescent and exotic formulations are also available in Fluropon Classic®, Fluropon Classic II®** and Fluropon Premiere®. In addition, AWV has the ability to apply other specialized coatings selected for specific chemical environments or to complement roofing, window, panel and siding systems. Please contact AWV for special pricing. ANODIZED FINISHES Clear anodizing pre-oxidizes aluminum surfaces to provide a uniform satin finish that resists the natural oxidizing that normally occurs with mill finish aluminum. The 204R1 clear (AA-M12C22A31) provides 0.4 mil coating thickness and is used for normal weather exposure. The 215R1 clear (AA-M12C22A41) provides 0.7 mil coating thickness and is recommended when severe corrosive or abrasive atmospheric conditions exist. Color anodize in light, medium, dark bronze or black (AA0-M12C22A44) electrolytically deposits color pigment to achieve a 0.7 mil coating thickness. Anodized finishes are only available in aluminum. WARRANTY AWV warrants our Kynar (aka PVDF) finish for a period of twenty (20) years. Gloss, shade or tone may vary slightly from color chips shown. A metal color sample can be provided for approval. *Fluropon® is a registered trademark of the Valspar Corporation. ** Fluropon Classic II® color is not measurable due to reflectance properties of mica flakes used to create pearlescent effects per 2605. STANDARD FINISH SPECIFICATIONS PVDF Salt Spray ASTM B 117 Hours: 3,000 Scribe: Rating 10, No creepage Field: Rating 10, No blisters Humidity ASTM D 2247 Hours: 4,000 Rating 10, No blisters Pencil Hardness ASTM D 3363 F minimum Specular Gloss ASTM D 523 20–35 at 60° Accelerated Weathering (Dew Cycle Weatherometer)ASTM D 3361 Hours: 1,000 total Chalk: Rating 8 Field: 5 ΔE Hunter units max* standard finishes KYNAR® STANDARD COLORS KYNAR® STANDARD MICA COLORS* These color samples are as close as possible to the actual colors offered within the limitations of color-chip reproduction. *Prices may vary from standard colors. CLEAR MICA CHAMPAGNE MICA LIGHT BRONZE MICA MEDIUM BRONZE MICA DARK BRONZE MICA KYNAR® COAL BLACK HARTFORD GREEN DARK BRONZE SANTA FE RED DOVE GRAY CHARCOAL BLACK AGED COPPER MEDIUM BRONZE BRICK RED SANDSTONE IBM BLUE PARCHMENT YELLOW BUCKSKIN TERRA COTTA ALAMO TAN SLATE GRAY CITATION GOLD SQUIRREL BROWN SIERRA WHITE BONE WHITE FULL-END SKIRT INSTALLATION DETAIL FASTEN TO WALL HARDWARE BY OTHERS RIGHT END SKIRT FASTEN TO HOOD INSIDE HOOD END PANEL END SKIRT 1/4-20 BOLT AND ACORN NUT LEFT END SKIRT NOTES: 1. REFER TO EQUIPMENT SCHEDULE FOR LOCATIONS OF FULL END SKIRTS MOUNTED ON EACH HOOD SECTION. 45 VERIFICATION OF HOOD HANGING HEIGHT ABOVE FINISHED FLOOR (A.F.F.) IS REQUIRED FOR CORRECT PLACEMENT OF FIRE SYSTEM NOZZLES. HOOD HANGING HEIGHT FOR FIRE SYSTEMS RECOMMENDED HANGING HEIGHT = 80" FROM FINISHED FLOOR TO LOWER FRONT EDGE OF HOOD. OTHER HANGING HEIGHT = __________" FROM FINISHED FLOOR TO LOWER EDGE OF HOOD. TYPICAL HANGER BRACKET SUPPLY PLENUM HANGER BRACKET DETAIL TYPICAL HANGER BRACKET ON HOODS OVER 120" HOOD HANGER BRACKET DETAIL NOT TO SCALE REFERENCE SCALED DRAWING FOR ACTUAL LOCATIONS TYPICAL HOOD HANGING METHOD THREADED ROD (1/2") WASHER HANGER BRACKET 1/2" NUT ROUND LED LIGHT DETAIL 115VAC HOT 115VAC NEUTRAL GROUND BLACK WHITEGREEN BLACK WHITEGREEN FIRST LED HOOD LIGHT SECOND LED HOOD LIGHT LAST LED HOOD LIGHTLIGHT QTY BASED ON CONFIGURATION NOTES: VOLTAGE: 115VAC, 50-60HZ WATTAGE: 20W EACH AMPERAGE: 0.167A EACH LUMENS: 1800 CONDUIT PORTS: 2 EACH (1/2" - 14 NPT) COLOR: 3900 - 4100K DIMMABLE (0-10VDC) BLACK (115VAC HOT) WHITE (115VAC NEUTRAL) GREEN (GROUND) PURPLE (DIM 0-10VDC +) GRAY (DIM 0-10VDC -) DRAWING NOT TO SCALE SUPPLY PLENUM INFORMATION POS.HOOD NO.MARK TYPEL COLLARS W L DIA.CFM S.P.INSULATED DAMPER(S)VEL. LED LIGHT(S) W H SIZE (IN.)TYPE MOUNTING QTYQTYSUPPLIED TOTAL CFM 1 ITEM 1 - KEH FRONT MUA 12 30 650 0.01 260FACTORY3130NO YES NO14 4ASP 1950 MODEL LENGTH WIDTH HEIGHT HOOD DIMENSIONS (IN.) MARK WIDTH LENGTH DIA. CFM S.P. COLLAR(S) EXHAUST HOOD INFORMATION HOOD NO. COOKING LOAD / DUTY RATING HOOD CONSTR.MUA CFM AC CFM TOTAL WEIGHT LBS. SECTION LOCATIONTOTAL CFM SUPPLY 10 23 0.55224381130 54 SINGLE24XXEW-130-S ITEM 1 - KEH 2438 1950 346.352HEAVY430 SS WHERE EXPOSED LIGHTING DETAILS QTY L GREASE FILTRATION DETAILS QTY H LOCATION UTILITY CABINET(S) CONTROLS HOOD INFORMATION MARK FIXTURE TYPE BULB / LAMP INFO FOOT CANDLES TYPE / MODEL MATERIAL SIZE (IN.)HOOD NO.FIRE SYSTEM MODELTYPE SIZE INTERFACE 72.49 0 208 20 161ROUND LED X-TRACTOR STAINLESS STEELITEM 1 - KEH 3 HOOD OPTIONS UL 710 LISTED W/ OUT EXHAUST FIRE DAMPER - UL #R25625 BACK INTEGRAL AIR SPACE - 3 IN WIDE FACTORY MOUNTED EXHAUST COLLAR(S) LEFT FULL END SKIRT - 45 IN HIGH 48.50 IN TOP WIDTH 42.5 IN BOTTOM WIDTH RIGHT FULL END SKIRT - 45 IN HIGH 48.50 IN TOP WIDTH 42.5 IN BOTTOM WIDTH PERFORMANCE ENHANCING LIP (PEL) TECHNOLOGY STANDING SEAM CONSTRUCTION FOR SUPERIOR STRENGTH 2 FP245 2 FP245 1 FP1N 3 FP3N 3 FP3N Range - 4 or more burnersFuel Type: Gas36" L X 30" W X 36" HGriddleFuel Type: Gas24" L X 30" W X 36" HFryer - Full Vat with DripboardFuel Type: Gas16" L X 30" W X 36" HFryer - Full Vat with DripboardFuel Type: Gas16" L X 30" W X 36" HCombi-OvenFuel Type: Gas34" L X 31" W X 36" HEND SKIRT END SKIRT 2 FP2W MARK: Item 1 - KEH - SECTION 1ELEVATION VIEW ITEM 1 - KEH118 WOODLAWN AVESARATOGA SPRINGS NY R1ACCUREX NYC METRO AREACHRIS LOWELLMARK.OSYATINSKY@ACCUREX.COM(919)802-3029PROJECTMARK3/28/20233" REAR INTEGRAL AIR SPACE MARK: Item 1 - KEH - SECTION 1PLAN VIEW PIPE & CONDUIT BY ANSUL DISTRIBUTOR TANK RELEASEWITH TANK ANSUL R102 FIRE SYSTEM MARK: Item 2 - FS TEMPERATURE SENSORSFIELD WIRING TO CONTROLS REQUIRED 46 IN. OC 1 FP1N1 FP1N CHROME APPLIANCE DROPS PERFORATED AIR CURTAIN FULL END SKIRTFULL END SKIRT MARK: Item 1 - KEH REMOVABLE GREASE CUP W/ CONCEALED GREASE TROUGH SECTION VIEW UL LISTED HIGH EFFICIENCY 'GREASE-X-TRACTOR' FILTERS UL LISTED LED LIGHT FIXTURE TEMPERATURE SENSORS SUPPLY PLENUM LENGTH 3.6 3.6 2.6 2.6 HOOD LENGTH 3.63.6 4.0 2.6 8.0 2.0 2.0 23.0 42.0 42.0 23.0 7.0 30.0 12.0 30.0 12.0 30.0 12.0 23.0 10.07.0 65.0 65.0 130.0 3.0 54.0 14.0 68.0 4.0 4.0 80.0 ABOVE FINISHED FLOOR 24.0 104.0 3.0 1. STAINLESS STEEL ENCLOSURE2. AGENT STORAGE TANK3. EXPELLENT GAS CARTRIDGE4. ANSUL AUTOMAN RELEASE5. REGULATOR6. KNOCKOUT FOR WIRING MICROSWITCH CONTROL PANEL 1 2 3 4 5 6 WET CHEMICAL FIRE PROTECTION SYSTEM TO BE ANSUL R-102, DESIGNED IN COMPLIANCE WITH UL 300 REQUIREMENTS. -VERIFICATION OF ALL COOKING EQUIPMENT MAKE, MODEL AND LOCATION REQUIRED FOR ALL FIRE PROTECTION SYSTEMS. -ALL FIRE SYSTEM PIPING IS STANDARDLY TO THE RIGHT END OF THE HOOD UNLESS A WALL IS LOCATED ON THE RIGHT END. -ANSUL AUTOMAN RELEASE TO BE LOCATED WITHIN 60" OF HOOD. THE BASIC FIRE SYSTEM WILL INCLUDE THE FOLLOWING: -GAS SHUT-OFF VALVE, IF REQUIRED, TO BE SUPPLIED BY MANUFACTURER (UP TO 2" DIAMETER AS STANDARD), AND INSTALLED BY A LICENSED PLUMBER. -MICRO SWITCH TO BE SUPPLIED BY MANUFACTURER FOR CONNECTION TO, BUT NOT LIMITED TO, BUILDING ALARM SYSTEM(S), EXHAUST AND SUPPLY FANS AND ELECTRICAL POWER SHUT DOWN. FIELD WIRING AND CONNECTIONS TO BE PERFORMED BY A LICENSED ELECTRICIAN. THE BASIC FIRE SYSTEM DOES NOT INCLUDE THE FOLLOWING: -FULL DUMP TEST OTHER THAN WHT IS SPECIFIED PER THE INSTALLATION MANUAL, OR TO SATISFY A STATE OR LOCAL CODE. PERMIT AND TESTING FEES ARE NOT INCLUDED UNLESS NOTED UNDER THE EQUIPMENT SCHEDULE FOR THE FIRE SYSTEM. -MORE THEN TWO TRIPS TO THE JOBSITE OR SPECIAL TRANSPORTATION, OR OVERNIGHT LODGING REQUIREMENTS IN REMOTE AREAS. NORMAL TRAVEL DISTANCE IS FIRST 50 MI. (80.5 KM) FROM OFFICE. - SPECIAL CLASSES OR ADDITIONAL LABOR FOR ACCESS TO SECURITY SENSITIVE AREAS. -INSTALLATION OF GAS SHUT-OFF VALVE. -SPECIAL DRAWINGS REQUIRED TO SATISFY STATE OR LOCAL CODE. PLAN EXAMINATION FEES, PE OR FS APPROVAL STAMP. -UNION LABOR, GOVERNMENT LABOR, OR PREVAILING WAGES REQUIRED FOR FINAL FIELD HOOK-UP. -ANY AND ALL ELECTRICAL COMPONENTS/CONNECTIONS REQUIRED TO SHUT DOWN FANS, SHUT OFF DEVICE FOR ELECTRIC COOKING EQUIPMENT (SHUNT TRIP BREAKER), OR ACTIVATE AN ALARM SYSTEM, ETC. -ANY DISMANTLING OR REASSEMBLY REQUIRED TO GAIN ACCESS TO THE FIRE SUPPRESSION PIPING LOCATED ON THE TOP OF THE HOOD. -ROUGH-IN HIDDEN CONDUIT FOR REMOTE PULL STATION OR GAS VALVE (FLUSH MOUNTED PULL STATION). -INSTALLATION OF MORE THAN (1) REMOTE PULL STATIONS OR DISTANCES GREATER THAN 20 FT (6.1M.) -PARTS OR LABOR REQUIRED TO CORRECT PIPING DUE TO COOKING EQUIPMENT CHANGES OR DEVIATION FROM PLANS. OR ANY CHARGES FOR MISSING OR ADDITIONAL PARTS OTHER THEN THOSE INDICATED ON THE FIRE SUPPRESSION DETAIL. NOTES: NOT TO SCALE NOTES: 1. 2. 3. DO NOT USE BLACK WIRE ON SNAP-ACTION SWITCH IN NORMAL INSTALLATION. BLACK WIRE TO BE USED ONLY FOR EXTRANEOUS ALARM, LIGHT CIRCUITS, ETC. NC NO } NC VOLTAGE FREE BUILDING ALARM(S) CONTACTS FORINPUT NO METHOD OF WIRING, IF PROHIBITED BY LOCAL CODES. DO NOT SHUT DOWN EXHAUST FANS WITH THIS NC NO FAN(S)N }INPUT120 VAC ~POWER TO FANSTARTER MANUAL SWITCH CONNECTION TO BUILDINGS ALARM CONNECTION TO FAN SHUT DOWN DPDT SWITCHES PROVIDED BY MANUFACTURER MAY BE WIRED PER TYPICAL EXAMPLES SHOWN. VERIFY WITH LOCAL CODES AND EQUIPMENT SUPPLIED AS THE CONNECTION NEEDED FOR YOUR INSTALLATION. WIRING DIAGRAMS W/DPDT MICRO SWITCH DENOTES FIELD INSTALLATION. DENOTES FACTORY INSTALLATION. SHUNT TRIP BREAKER POWER TO COOKING EQUIPMENT ELECTRIC GAS VALVE - IF RESET RELAY IS USEDSEE OPTION A OR B AT RIGHT, MECHANICAL GAS SHUT OFF VALVE DOES NOT REQUIREELECTRICAL CONNECTION. CONNECTION TO COOKING EQUIPMENT SHUT DOWN N }INPUT120 VAC 23.5 16.57.5 ANSUL R102 (WET CHEMICAL) FIRE PROTECTION SYSTEM - MODEL FSSC CONTINUOUS FUSIBLE LINK ANSUL R-102 WET CHEMICAL 15 UTILIZED 22 AVAILABLEREMOTE MOUNTEDITEM 2 - FS MODELMARK FIRE SYSTEM INFORMATION LOCATION FLOW POINTS SUPPLY LINE DETECTION MARK(S) PROTECTED BY FIRE SYSTEMHOODS PCU ITEM 1 - KEH SECTION 1 FIRE SYSTEM OPTIONS AND ACCESSORIES FULL INSTALLATION (INCLUDES PRE-PIPED HOOD(S) WITH DETECTION AND FACTORY COORDINATED INSTALL) CHROME SLEEVES FOR FACTORY PROVIDED APPLIANCES DROPS - INCLUDED METAL BLOW-OFF CAPS - INCLUDED GAS VALVE - INCLUDED - MECHANICAL SHUTOFF VALVE, 2", (ANSUL) - PART# ANSULMECHSHUTOFFVALVE200 HOOD SUPPRESSION TANK - INCLUDED - 6 GAL. - [(2) 3.0 TANK(S)] REMOTE PULL STATION - STANDARD - FIELD INSTALLATION AT SINGLE POINT OF EGRESS ITEM 2 - FS118 WOODLAWN AVESARATOGA SPRINGS NY R1ACCUREX NYC METRO AREACHRIS LOWELLMARK.OSYATINSKY@ACCUREX.COM(919)802-3029PROJECTMARK3/28/2023ITEM 2 - FS118 WOODLAWN AVESARATOGA SPRINGS NY R1ACCUREX NYC METRO AREACHRIS LOWELLMARK.OSYATINSKY@ACCUREX.COM(919)802-3029PROJECTMARK3/28/2023 ITEM 3 - KEF118 WOODLAWN AVESARATOGA SPRINGS NY R1ACCUREX NYC METRO AREACHRIS LOWELLMARK.OSYATINSKY@ACCUREX.COM(919)802-3029PROJECTMARK3/28/2023One piece fully welded windband High Temp Curb Seal Rated for Continuous Duty at 1500 F (Factory Attached) Grease Trap (PN 475538) Tapered bushing wheel hub Breather tube outlet area min. 4.4 sq. in. (sizes 99-480), 2.0 sq. in. (sizes 60-95) Min. windband material thickness: 0.051" aluminum (060-240), 0.064" aluminum (240HP, 240XP), 0.080" aluminum (sizes 300-480) Larger Curb Cap Size - 26 Square UL/cUL 762 Listed - "Power Ventilators for Rest. Exh. Appliances" Switch, NEMA-3R, Toggle, Shipped with Unit Hinge, Factory Installed MODEL OPERATING POWER (HP)V/C/P ENCLOSUREVOLUME (CFM) FAN RPMQTY Direct Drive Upblast Centrifugal Roof Exhaust Fan MOTORRPM WINDINGS MOTOR INFORMATION SIZE (HP)WEIGHT (LB.)MARK TOTAL EXTERNAL SP (IN WG) MARK INFORMATION FAN INFORMATION XCUE-160-VG 0.74 208/60/1 OP2,438 1,2511 1300 1 1100Item 3 - KEF 1.052 Item 3 - KEF : SELECTED OPTIONS AND ACCESSORIES 5:12 PITCH5:12 PITCH RECOMMENDED EXHAUST DUCT SIZE STANDARD FIRE-WRAPPED 18 SQ 12 SQ DUCT TYPE SIZE MAXIMUM ROOF OPENING OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR, ADAPTER, AND/OR HINGE BASE. DUCT DIMENSIONS ARE LARGEST POSSIBLE DUCT TO FIT THROUGH CURB. CONSULT SYSTEM DESIGN ENGINEER FOR RECOMMENDED DUCT SIZE. 5:12 PITCH 26.00 SQ 3.44 19.56 29.75 Ø 28.88 53.75 (24.00) 26.00 SQ Ø 28.88 53.75 (24.00) See Table 22.50 SQ 26.00 SQ Curb Cap 28.50 30.54 24.00 24.50 24.50 NOTE: Roof Opening Requirements: Minimum Roof Opening: The minimum roof opening size is the illustrated duct diameter plus 0.25 in. on all sides. For example: If the duct size is 14 x 14 in. square, the minimum roof opening size is 14.5 x 14.5 in. square. Maximum Roof Opening: There must be a minimum perimeter of 1.75 in. between the roof opening and the roof curb. For example: If the roof curb is 75 x 30 in. square, the maximum roof opening is 71.5 x 26.5 in. inches square. NOTE: The weatherhood and filter sections of the make-up air unit are not supported by the curb. This is by design, in order to help alleviate water infiltration issues. EQUIPMENT SCHEDULE Accurex Model Operating Power VolumeQty Tempered Make-Up Air Unit Mark:Item 4 - MUA Weight XDGX-P109-H12-MF 0.84 hp 1,950 CFM1 615 lb V/C/P Enclosure Motor RPM MCA Motor Information Size 208/60/1 ODP 3600 14.4 1 1/2 hp MOP 25 Total SPExternal SP 1.214 in. wg0.51 in. wg Motor with Shaft Gounding No SCCR 5kA Gas Type OutputWinter DB Max LAT InputType Heating Connection Gas (IN) Natural 151.4 MBH-1.9 F 70.0 F 164.6 MBHDirect Gas 3/4" Control Access Right Hand BuildingGasPressure 1/2 PSI Max Δ 71.9 F EnergyTemperature Efficiency 92% Min 7 in. wg Max 0.5 PSI Gas Pressure 125 40002501000 200062.5 Outlet Sound Power By Octave Band 8000 70.9 79.671.2 77.6 80.182.1 72.8 dBA 74.2 LwA 85.2 500 74.4 Sones 22.6 ·LwA - A weighted sound power level based on ANSI S1.4·dBA - A weighted sound pressure level base on 11.f dB attenuation per octabe band at 5.0 ft. ·Noise Criteria (NC) based on an average attenuation of 11.5 dB per octabe band at 5.0 ft. OPTIONS AND ACCESSORIES Air Flow Arrangement: Outdoor Air Only Access Side: Right-Hand Control Center Heat Inlet Air Sensor Unit Controls: Terminal Strip Temperature Control: Discharge Direct Gas Options/Accessories Approvals: ETL FM Compliant Flame Sensing: Flame Rod Ignition Control: Pilot Weatherhood: Aluminum Mesh, 16x20x2 - (4) Unit Rated Gas Pressure: 1/2 PSI Unit Warranty: 18 Months (std.) Damper: Inlet Outdoor Air Intake Position: End Discharge Position: Bottom Coating: Galvanized Insulation: Double Wall - Tempering On Supply Fan Control: VFD VFD Control: Constant Volume ELEVATION VIEW END VIEW FOOTPRINT INTAKE ACCESS SIDE BURNER ACCESS SIDE CONTROL CENTER SUPPLY DUCT ACCESS SIDE MIXFLOW BLOWER PLAN VIEW ITEM 4 - MUA118 WOODLAWN AVESARATOGA SPRINGS NY R1ACCUREX NYC METRO AREACHRIS LOWELLMARK.OSYATINSKY@ACCUREX.COM(919)802-3029PROJECTMARK3/28/2023LEGEND CAUTION UNIT SHALL BE GROUNDED IN ACCORDANCE WITH N.E.C. POWER MUST BE OFF WHILE SERVICING. NOTES USE COPPER CONDUCTORS ONLY FIELD CONTROL WIRING RESISTANCE SHOULD FIELD WIRED FACTORY SUPPLIED AND WIRED WIRE COLOR CODE Wiring Diagram Code: BK BLACK BL BLUE BR BROWN GY GRAY LT BL LIGHT BLUE O ORANGE PK PINK PR PURPLE R REDW WHITE Y YELLOW Wiring Template: M24 AMP AMPLIFIER D1 INLET DAMPER DS1 MAIN DISCONNECT SWITCH FSC FIRE SYSTEM CONTACT FSG FLAME SAFE GUARD FU# FUSEHLC HIGH LIMIT CONTROL M# MOTOR MOD MODULATING VALVEPS2 AIR PROVING SWITCH RF SUPPLY FAN RELAY RF1 FAN ENABLE RELAY RH HEAT RELAYS2 FAN SWITCH S4 HEAT AND COOL SWITCH SG SPARK GENERATORST# MOTOR STARTER TR# TRANSFORMER TS2 DISCHARGE AIR SENSORTS4 INLET AIR SENSOR - HEAT V1 PILOT VALVEV2 MAIN VALVE VFD VARIABLE FREQUENCY DRIVE INLET DAMPERD1 RED RFA2 A1 SUPPLY FAN RELAYG S4 W1 TS4 R B MCMB VFD PINK RED PINK 5 GROUND TO UNIT MAIN POWER 208V S2 FSC 24V TR1 CR BLUEWHITEPINK 111 112 BLACK 2CBL-ID RED 2CBL-ID PS2 PS2 NC CC NO 27 1 MOD 5 6 AMP 7 8 TS2 3 412 10 SEC DISCHARGE STAT.BLACKWHITEBLUEBLUEINT 1 2 TEMP RANGE55-90° F 21 RF W1 RED RHA2 A1 POST HEAT24 40VA 22 21 24V REDBLACKRED TR5 SC RF 11 14 S1 YPR VFDH-0-1 DOC NUMBER: ----REV: ---- (24V)PV FSG SPARK 21 SENSESENSOR SPARK TR6 V1 39 38 LT BLUE 22 2311 RH 14 RED RED HLC1 24 TH/24V BLUE YELLOW 24 VAC WHITE WHITE R R DIRECT GAS CONTROLO GND GND(BURNER) V237ORANGE WHITE MV BLUE 29 A C C U RE X ALM92YELLOW L2 L3 L1 VFD T1 T2 T3 SUPPLY FANMOTOR L3 L1 DS1 M1 T3 T1 60° C FOR TERMINALS RATED LESS THAN 100 AMPS. 75° C FOR TERMINALS RATED 100 AMPS OR MORE. NOT EXCEED 0.75 OHM. AD61N202B010N10NM24 Supply Duct 96.125 31.480 37.596 39.02 27.05 33.241 39.020 31.480 37.596 33.656 27.049 22.750 16.750 5.688 5.125 5.20 3.60 3.15 61.750 CURB LENGTH ACTUAL 29.500 CURB WIDTH ACTUAL 16.750 22.750 1 EXHAUST E1 ITEM 3 - KEF 2438 NO --- 10.0--Z1 2 SUPPLY S1 ITEM 4 - MUA 1950 NO --- 10.0--Z1 WDC# JOB NAME:118 WOODLAWN AVE SARATOGA SPRINGS NY R1 MODEL: SERIAL NUMBER: XKC-CV-SR-11-1-1-0 WIRING DIAGRAM CODE: MARK:ITEM 5 - CONTROLS WDSN# DOC NUMBER: ----REV: ---- FACTORY SETTINGS TYPE: CV CONFIGURATION: STANDARD ZONES: 1 HOODS: 1 SUMPS: 0 EXHAUST FANS: 1 SUPPLY FANS: 1 MB ROOM SENSOR: YES MB TEMP SENSORS: 1 HIGH TEMP FAULT: NO FREEZE PROTECTION: YES GAS RESET: NO FAN PROVING: NO BMS: NONE ZONE SETTINGS SEE ZONE CONFIGURATION IN TABLE ON LEFT HOOD SETTINGS SEE HOOD CONFIGURATION IN TABLE ON LEFT EXHAUST FAN SETTINGS SEE FAN CONFIGURATION IN TABLE ON LEFT SUPPLY FAN SETTINGS SEE FAN CONFIGURATION IN TABLE ON LEFT SENSOR SETTINGS SEE HOOD CONFIGURATION IN TABLE ON LEFT USER INTERFACE SETTINGS (MB) FAN & LIGHT BUTTONS: SHOW BOTH (SEPERATE) USER INTERFACE SETTINGS (HCB) NA GENERAL SETTINGS TIME ZONE: CENTRAL DAYLIGHT (DEFAULT) FIRE/FAULT SETTINGS EXHAUST DURING FIRE: MAX SUPPLY DURING FIRE: OFF LIGHTS DURING FIRE: OFF BMS SETTINGS ZONE CONFIGURATION ZONE #ZONE ROOM TEMP HOOD # HOOD HOOD MARK ZONE EXHAUST SUPPLY MB-TEMP SENSORS HCB HOOD CONFIGURATION FAN CONFIGURATION FAN #TYPE FAN FAN MARK MAX CFM MODBUS VFD VFD ADDRESS MIN FREQ.MIN VDC MAX VDCMAX FREQ.MIN CFMZONE DEFAULT SETTINGS / PARAMÈTRES PAR DÉFAUT NA PRG VERSION: V4 1 H1 ITEM 1 - KEH SECTION 1 Z1 E1 S1 TS1 NO 1 Z1 MB-RS DRAWING NOT TO SCALE CABINET DETAILS USER INTERFACE DETAILS ROOM SENSOR DETAILSMOUNTING LOCATION: SHIP LOOSE ENCLOSURE NOTES: 1) WHEN CONTROLS ARE MOUNTED IN HOOD-MOUNTED OR WALL-MOUNTED UTILITY CABINET, FOR HOOD OR WALL CABINET DIMENSIONS SEE HOOD SUBMITTAL. 2) MINIMUM OF 36" OF CLEARANCE RECOMMENDED IN FRONT OF CONTROL CABINET DRAWING NOT TO SCALE DRAWING NOT TO SCALE MOUNTING TYPE RECESSED INTO WALL USER INTERFACE CONTROL FANS AND LIGHTS INTERFACE CABLE LENGTH 50FT (FACTORY PROVIDED) MOUNTING TYPE SHIP LOOSE: SURFACE MOUNT WIRING BY OTHERS (USE 18/2) TOTAL WEIGHT: 25 LBS MARK CONTROL INFORMATION MODEL LOCATION USER INTERFACE LOCATION ELECTRICAL CONTROL PACKAGE TYPE FANS CONTROLLED ZONE CFMFAN #TYPE FAN FAN MARK MOTOR VOLT CYCLE MOTOR STARTER IN PANEL VFD IN PANELMOTOR PHASEMOTOR HP FULL COLOR TOUCHSCREEN SHIP LOOSEXKC-CV-SR-11-1-1-0 SHIP LOOSE ENCLOSUREITEM 5 - CONTROLS 1 24381 EXHAUST E1 ITEM 3 - KEF 208 60 NO NO11 1 19502 SUPPLY S1 ITEM 4 - MUA 208 60 NO NO11.5 CONTROL FEATURES HOOD LIGHT CONTROL TEMP SENSORS (FACTORY INSTALLED) - QTY. 1 ROOM SENSOR (SHIPPED LOOSE) - QTY. 1 DRY FIRE CONTACTS - QTY. 2 LIGHTS OFF DURING FIRE EXHAUST MAX DURING FIRE SUPPLY OFF DURING FIRE WDC# POWER WIRING FOR KITCHEN CONTROLS 43BM COMMERCIAL APPLIANCE OUTLET CENTER ELECTRICAL RATINGS: 110-240V,1PHASE, 50 -60HZ,15A BASE FILE #E200616, ML FILE #E313951 SHUNT TRIP (BY OTHERS) WIRING EXAMPLE: C1 NO1 COMMON NORMALLY OPEN APPLIANCE CONTACTORS (BY OTHERS) WIRING EXAMPLE: HOT NEUTRAL SHUNT TRIP BREAKER COIL C1 NC1 COMMON NORMALLY CLOSED HOT NEUTRAL APPLIANCE CONTACTOR COIL *FIRE SYSTEM DRY CONTACT WIRING EXAMPLES MAIN CONTROL PANEL CONTROL WIRING FOR KITCHEN CONTROLS MB (MAIN BOARD) JOB NAME:118 WOODLAWN AVE SARATOGA SPRINGS NY R1 MODEL: SERIAL NUMBER: CAUTION (WIRING TO BE DONE BY ELECTRICIAN)(WIRING TO BE DONE BY ELECTRICIAN, IF NO CONTROLS CONTRACTOR. USE 18-22GA WIRE UNLESS SPECIFIED.) MAIN CONTROL PANEL (CONTINUED) XKC-CV-SR-11-1-1-0 THESE DRAWINGS SHALL NOT BE REMOVED FROM THIS EQUIPMENT. USE COPPER CONDUCTORS RATED TO 90°C UNLESS SPECIFIED. TORQUE CONTROL & GROUND BLOCKS TO 8 LBS. IN. TORQUE POWER LUGS/SCREWS TO COMPONENT RATINGS LISTED. TORQUE CONTROL BOARD SCREW TERMINALS TO 3.5 LBS. IN. FIELD CONTROL WIRING RESISTANCE SHOULD NOT EXCEED 0.75 OHM. SEE IOM FOR ADDITIONAL INFORMATION, OR CALL FACTORY AT 1-800-371-6858. FS-C FS-NC RS-A RS-B C NC NO FIRE SUPPRESSION FIRE SYSTEM SWITCH (REMOVE JUMPER IF USED)** ROOM SENSOR (SHIPPED LOOSE) DI-1A DI-1B DI-2A DI-2B DIGITAL IN 1 FAN ON/OFF (DEFAULT) C NO DIGITAL IN 2 LIGHT ON/OFF (DEFAULT)C NO WILL BE FACTORY WIRED IF MOUNTED NEXT TO FIRE SYSTEM **WHEN FIRE SYSTEM IS ARMED, FS-C TO FS-NC SHOULD HAVE CONTINUITY WIRING DIAGRAM CODE: MARK:ITEM 5 - CONTROLS DOC NUMBER: ----REV: ---- WDSN# ATTENTION UNIT MUST BE GROUNDED IN ACCORDANCE WITH N.E.C. POWER MUST BE OFF WHILE SERVICING. L’APPAREIL DOIT ÊTRE MIS À LA TERRE CONFORMÉMENT AU CODE C.E. L’ALIMENTATION DOIT ÊTRE COUPÉE DURANT L’ENTRETIEN. NE PAS RETIRER CES DESSINS DE CET ÉQUIPEMENT. SAUF INDICATION CONTRAIRE, UTILISER DES CONDUCTEURS EN CUIVRE CLASSÉS 90 °C. SERRER LES BORNES DE COMMANDE ET DE MISE À LA TERRE À 8 LB-PO. SERRER LES COSSES/VIS D’ALIMENTATION AUX COUPLES INDIQUÉS POUR LE COMPOSANT. SERRER LES BORNES À VIS DE LA CARTE DE COMMANDE À 3,5 LB-PO. LA RÉSISTANCE DU CÂBLAGE DE COMMANDE LOCAL NE DOIT PAS DÉPASSER 0,75 OHM. POUR PLUS D’INFORMATION, CONSULTER LE MANUEL OU APPELER 1-800-371-6858 PRG VERSION: V4 FIELD WIRED (CÂBLÉ LOCALEMENT) FACTORY WIRED (CÂBLÉ À L’USINE) (OPTIONAL ON/OFF INPUTS) POWER WIRING FROM BREAKER PANEL DIRECT TO FANS BUILDING BREAKER PANEL (WIRING TO BE DONE BY ELECTRICIAN) BUILDING BREAKER PANEL MAIN CONTROL PANEL H1 N1 GND HOT NEUTRAL GROUND LTS-H LTS-N GND L LBLACK WHITE GREEN C1 NO1 NC1 COMMON NORMALLY OPEN NORMALLY CLOSED C2 NO2 NC2 FIRE SYSTEM DRY CONTACT 1* COMMON NORMALLY OPEN NORMALLY CLOSED FIRE SYSTEM DRY CONTACT 2* UPON FIRE OR NO POWER TO PANEL: C TO NO WILL CLOSE C TO NC WILL OPEN UPON FIRE OR NO POWER TO PANEL: C TO NO WILL CLOSE C TO NC WILL OPEN 110V-120V / 1PH POWER FOR CONTROLS / LIGHTS (NON SHUNTED 15A BREAKER) HOOD LIGHTS 115VAC 1200W MAX E1-S+ E1-S- 0-10VDC + 0-10VDC -FAN SPEED0-10VDC OUT VARI- GREEN MOTOR (ECM) RED WHITE EXHAUST E1MARK: ITEM 3 - KEF S1-RA S1-RB DRY RUNOUTPUT R G MUA UNIT SUPPLY S1MARK: ITEM 4 - MUACOMMON NORMALLY-OPEN 208V / 1PH POWER FOR E1 MCA: 8.25 MOP: 15 LINE 1 GROUND EXHAUST E1 208V / 1PH M 1 HP8.8 FLA MARK: ITEM 3 - KEF DS1LINE 2 208V / 1PH POWER FOR S1 MCA: 14.40 MOP: 25 LINE 1 GROUND SUPPLY S1 208V / 1PH M 1.5 HP11.0 FLA MARK: ITEM 4 - MUA DS1LINE 2 TS-1A TS-1B HOOD 1 TEMP SENSOR HOOD MARK: ITEM 1 - KEH SECTION 1 MAIN BOARD USER INTERFACE MB-UI J15 FACTORY PROVIDED 50 FT CAT5 CABLE SHIPPED LOOSE ITEM 5 - CONTROLS118 WOODLAWN AVESARATOGA SPRINGS NY R1ACCUREX NYC METRO AREACHRIS LOWELLMARK.OSYATINSKY@ACCUREX.COM(919)802-3029PROJECTMARK3/28/20235.32 2.25 4.00 4.00 5.25 12 6 20 4.50 2.80 1.10 OVERVIEW • SPECIFICATIONS • ORDERING INTERIOR + EXTERIOR | L50 GRAZE DATE PROJECT FIRM TYPE 1 /3 20221209 P • 310.496.6255 F • 310.496.6256 T • 855.632.6736 855.6.ECOSEN SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS. © 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THE ECOSENSE LOGO, RISE, TROV, SLIM COVE AND ECOSPEC ARE REGISTERED TRADEMARKS OF ECOSENSE LIGHTING INC. FREEDOM TO CREATE™ ECOSENSE LIGHTING INC. 837 NORTH SPRING STREET SUITE 103 LOS ANGELES, CA 90012 NOTE: Information on this Spec Sheet is subject to change, please visit ecosenselighting.com/downloads/rise for the most updated information. OPTICSCRI 80 90* Blank For Color CCT WHITE CCT 22 27 30 35 40 50 POWER 02 04 06 08 10 12 LENGTH 12" 48" INTERIOR/ EXTERIOR I E MODEL/ SIZE L50 V OLTAGE MULT (120-277V) MONO COLOR GR**** BL AM RD*** THE L50 INCLUDES PATENTED OPTICAL DESIGN THAT DELIVERS THE WIDEST RANGE OF BEAM ANGLE OPTIONS FOR PRECISE COVE, WALL GRAZING, WALL WASHING OR LINE OF LIGHT APPLICATIONS. EXCLUSIVE FLIP TO FLAT™ HINGE DESIGN PROVIDES FLEXIBILITY WHEN MANAGING SMALL COVE DETAILS. TROV OFFERS SMOOTH, FLICKER FREE DIMMING DOWN TO 0%. FEATURES : • DIM TO 0%, ELV REVERSE PHASE • 24 BEAM ANGLES • MULTI-VOLT • FLIP TO FLAT™ • 6 CCT OPTIONS • 80+ AND 90+ CRI OPTIONS • IP54 INTERIOR AND IP66 EXTERIOR OPTIONS PERFORMANCE WATTS OPTIC LUMEN OUTPUT EFFICACY COLOR RENDERING INDEX 80+, 90+ COLOR CONSISTENCY 2-STEP MACADAM ELLIPSE LUMEN DEPRECIATION / RATED LIFE WATTS L70 @ 25C L70 @ 50C L90 @ 25C L90 @ 50C *CALCULATIONS FOR LED FIXTURES ARE BASED ON MEASUREMENTS THAT COMPLY WITH IES LM-80 TESTING PROCEDURES AND IES TM-21 CALCULATOR2W-12W >150,000 >70,000 >50,000 >25,000 2W 9˚x 29˚158 Im/LF ( 519 lm/m )79 Im/W 4W 9˚x 29˚389 Im/LF ( 1277 lm/m )97 Im/W 6W 9˚x 29˚620 Im/LF ( 2035 lm/m )103 Im/W 8W 9˚x 29˚864 Im/LF ( 2833 lm/m )108 Im/W 10W 9˚x 29˚1046 Im/LF ( 3432 lm/m )105 Im/W 12W 9˚x 29˚1217 Im/LF ( 3990 lm/m )101 Im/W ALL LUMEN DATA IS FROM 4000K 80CRI FIXTURES. PLEASE SEE PHOTOMETRY SPEC SHEET FOR ADDITIONAL LUMEN DATA. * CALCULATIONS FOR LED FIXTURES ARE BASED ON MEASUREMENTS THAT COMPLY WITH IES LM-80 TESTING PROCEDURES AND IES TM-21 CALCULATOR ELECTRICAL POWER FACTOR 4W, 6W, 8W, 10W, 12W >0.9, 2W<0.9 STARTUP TEMPERATURE -40˚F TO 122˚F (-40˚C TO 50˚C) OPERATING VOLTAGE MULTIVOLT: 110-277VAC, 50/60 Hz OPERATING TEMPERATURE -40˚F TO 122˚F (-40˚C TO 50˚C) DRIVER INTEGRAL TO FIXTURE; DE-RATED POWER AND SYNCHRONOUS START-UP AT FULL BRIGHTNESS STORAGE TEMPERATURE -40˚F TO 176˚F (-40˚C TO 80˚C) MAX FIXTURE RUN LENGTH 2W/LF 4W/LF 6W/LF 8W/LF 10W/LF 12W/LF Volts Max Run all 1’ Max Run all 4’ Max Run all 1’ Max Run all 4’ Max Run all 1’ Max Run all 4’ Max Run all 1’ Max Run all 4’ Max Run all 1’ Max Run all 4’ Max Run all 1’ Max Run all 4’ 120 214 214 186 186 152 152 114 114 91 91 76 76 220 374 392 340 340 277 277 209 209 95 167 95 139 277 374 494 374 428 349 349 263 263 95 190 95 175 POWER CONSUMPTION 2W*/LF (6.6W/M) ; 4W/LF (13.2W/M) ; 6W/LF (19.8W/M) ; 8W/LF (26.4W/M) ; 10W/LF (33W/M) ; 12W/FL (39.6W/M) * 3W/LF (9.9W/M) at 220V -277V GRAZING 9 x 9 9 x 17 9 x 29 9 x 59 15 x 15 15 x 23 15 x 35 15 x 65 COVE 120** Asym LINE OF LIGHT LOL WASHING 25 x 25 25 x 33 25 x 45 25 x 75 39 x 9 55 x 25 40 x40 40 x 48 40 x 60 40 x 90 45 x 15 70 x 40 70 x 70 EXAMPLE: L50-I-48-10-27-90-MULT-15x65 *90 CRI not available in 2200K or 5000K **120 is only available with Exterior option. See L35 spec sheet for interior cove options. ***Red is not available in 12W or 10W. ****Green is not available in 12W. OVERVIEW • SPECIFICATIONS • ORDERING INTERIOR + EXTERIOR | L50 GRAZE DATE PROJECT FIRM TYPE 1 /3 20221209 P • 310.496.6255 F • 310.496.6256 T • 855.632.6736 855.6.ECOSEN SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS. © 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THE ECOSENSE LOGO, RISE, TROV, SLIM COVE AND ECOSPEC ARE REGISTERED TRADEMARKS OF ECOSENSE LIGHTING INC. FREEDOM TO CREATE™ ECOSENSE LIGHTING INC. 837 NORTH SPRING STREET SUITE 103 LOS ANGELES, CA 90012 NOTE: Information on this Spec Sheet is subject to change, please visit ecosenselighting.com/downloads/rise for the most updated information. OPTICSCRI 80 90* Blank For Color CCT WHITE CCT 22 27 30 35 40 50 POWER 02 04 06 08 10 12 LENGTH 12" 48" INTERIOR/ EXTERIOR I E MODEL/ SIZE L50 V OLTAGE MULT (120-277V) MONO COLOR GR**** BL AM RD*** THE L50 INCLUDES PATENTED OPTICAL DESIGN THAT DELIVERS THE WIDEST RANGE OF BEAM ANGLE OPTIONS FOR PRECISE COVE, WALL GRAZING, WALL WASHING OR LINE OF LIGHT APPLICATIONS. EXCLUSIVE FLIP TO FLAT™ HINGE DESIGN PROVIDES FLEXIBILITY WHEN MANAGING SMALL COVE DETAILS. TROV OFFERS SMOOTH, FLICKER FREE DIMMING DOWN TO 0%. FEATURES : • DIM TO 0%, ELV REVERSE PHASE • 24 BEAM ANGLES • MULTI-VOLT • FLIP TO FLAT™ • 6 CCT OPTIONS • 80+ AND 90+ CRI OPTIONS • IP54 INTERIOR AND IP66 EXTERIOR OPTIONS PERFORMANCE WATTS OPTIC LUMEN OUTPUT EFFICACY COLOR RENDERING INDEX 80+, 90+ COLOR CONSISTENCY 2-STEP MACADAM ELLIPSE LUMEN DEPRECIATION / RATED LIFE WATTS L70 @ 25C L70 @ 50C L90 @ 25C L90 @ 50C *CALCULATIONS FOR LED FIXTURES ARE BASED ON MEASUREMENTS THAT COMPLY WITH IES LM-80 TESTING PROCEDURES AND IES TM-21 CALCULATOR2W-12W >150,000 >70,000 >50,000 >25,000 2W 9˚x 29˚158 Im/LF ( 519 lm/m )79 Im/W 4W 9˚x 29˚389 Im/LF ( 1277 lm/m )97 Im/W 6W 9˚x 29˚620 Im/LF ( 2035 lm/m )103 Im/W 8W 9˚x 29˚864 Im/LF ( 2833 lm/m )108 Im/W 10W 9˚x 29˚1046 Im/LF ( 3432 lm/m )105 Im/W 12W 9˚x 29˚1217 Im/LF ( 3990 lm/m )101 Im/W ALL LUMEN DATA IS FROM 4000K 80CRI FIXTURES. PLEASE SEE PHOTOMETRY SPEC SHEET FOR ADDITIONAL LUMEN DATA. * CALCULATIONS FOR LED FIXTURES ARE BASED ON MEASUREMENTS THAT COMPLY WITH IES LM-80 TESTING PROCEDURES AND IES TM-21 CALCULATOR ELECTRICAL POWER FACTOR 4W, 6W, 8W, 10W, 12W >0.9, 2W<0.9 STARTUP TEMPERATURE -40˚F TO 122˚F (-40˚C TO 50˚C) OPERATING VOLTAGE MULTIVOLT: 110-277VAC, 50/60 Hz OPERATING TEMPERATURE -40˚F TO 122˚F (-40˚C TO 50˚C) DRIVER INTEGRAL TO FIXTURE; DE-RATED POWER AND SYNCHRONOUS START-UP AT FULL BRIGHTNESS STORAGE TEMPERATURE -40˚F TO 176˚F (-40˚C TO 80˚C) MAX FIXTURE RUN LENGTH 2W/LF 4W/LF 6W/LF 8W/LF 10W/LF 12W/LF Volts Max Run all 1’ Max Run all 4’ Max Run all 1’ Max Run all 4’ Max Run all 1’ Max Run all 4’ Max Run all 1’ Max Run all 4’ Max Run all 1’ Max Run all 4’ Max Run all 1’ Max Run all 4’ 120 214 214 186 186 152 152 114 114 91 91 76 76 220 374 392 340 340 277 277 209 209 95 167 95 139 277 374 494 374 428 349 349 263 263 95 190 95 175 POWER CONSUMPTION 2W*/LF (6.6W/M) ; 4W/LF (13.2W/M) ; 6W/LF (19.8W/M) ; 8W/LF (26.4W/M) ; 10W/LF (33W/M) ; 12W/FL (39.6W/M) * 3W/LF (9.9W/M) at 220V -277V GRAZING 9 x 9 9 x 17 9 x 29 9 x 59 15 x 15 15 x 23 15 x 35 15 x 65 COVE 120** Asym LINE OF LIGHT LOL WASHING 25 x 25 25 x 33 25 x 45 25 x 75 39 x 9 55 x 25 40 x40 40 x 48 40 x 60 40 x 90 45 x 15 70 x 40 70 x 70 EXAMPLE: L50-I-48-10-27-90-MULT-15x65 *90 CRI not available in 2200K or 5000K **120 is only available with Exterior option. See L35 spec sheet for interior cove options. ***Red is not available in 12W or 10W. ****Green is not available in 12W. OVERVIEW • SPECIFICATIONS • ORDERING INTERIOR + EXTERIOR | L50 GRAZE DATE PROJECT FIRM TYPE 1 /3 20221209 P • 310.496.6255 F • 310.496.6256 T • 855.632.6736 855.6.ECOSEN SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS. © 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THE ECOSENSE LOGO, RISE, TROV, SLIM COVE AND ECOSPEC ARE REGISTERED TRADEMARKS OF ECOSENSE LIGHTING INC. FREEDOM TO CREATE™ ECOSENSE LIGHTING INC. 837 NORTH SPRING STREET SUITE 103 LOS ANGELES, CA 90012 NOTE: Information on this Spec Sheet is subject to change, please visit ecosenselighting.com/downloads/rise for the most updated information. OPTICSCRI 80 90* Blank For Color CCT WHITE CCT 22 27 30 35 40 50 POWER 02 04 06 08 10 12 LENGTH 12" 48" INTERIOR/ EXTERIOR I E MODEL/ SIZE L50 V OLTAGE MULT (120-277V) MONO COLOR GR**** BL AM RD*** THE L50 INCLUDES PATENTED OPTICAL DESIGN THAT DELIVERS THE WIDEST RANGE OF BEAM ANGLE OPTIONS FOR PRECISE COVE, WALL GRAZING, WALL WASHING OR LINE OF LIGHT APPLICATIONS. EXCLUSIVE FLIP TO FLAT™ HINGE DESIGN PROVIDES FLEXIBILITY WHEN MANAGING SMALL COVE DETAILS. TROV OFFERS SMOOTH, FLICKER FREE DIMMING DOWN TO 0%. FEATURES : • DIM TO 0%, ELV REVERSE PHASE • 24 BEAM ANGLES • MULTI-VOLT • FLIP TO FLAT™ • 6 CCT OPTIONS • 80+ AND 90+ CRI OPTIONS • IP54 INTERIOR AND IP66 EXTERIOR OPTIONS PERFORMANCE WATTS OPTIC LUMEN OUTPUT EFFICACY COLOR RENDERING INDEX 80+, 90+ COLOR CONSISTENCY 2-STEP MACADAM ELLIPSE LUMEN DEPRECIATION / RATED LIFE WATTS L70 @ 25C L70 @ 50C L90 @ 25C L90 @ 50C *CALCULATIONS FOR LED FIXTURES ARE BASED ON MEASUREMENTS THAT COMPLY WITH IES LM-80 TESTING PROCEDURES AND IES TM-21 CALCULATOR2W-12W >150,000 >70,000 >50,000 >25,000 2W 9˚x 29˚158 Im/LF ( 519 lm/m )79 Im/W 4W 9˚x 29˚389 Im/LF ( 1277 lm/m )97 Im/W 6W 9˚x 29˚620 Im/LF ( 2035 lm/m )103 Im/W 8W 9˚x 29˚864 Im/LF ( 2833 lm/m )108 Im/W 10W 9˚x 29˚1046 Im/LF ( 3432 lm/m )105 Im/W 12W 9˚x 29˚1217 Im/LF ( 3990 lm/m )101 Im/W ALL LUMEN DATA IS FROM 4000K 80CRI FIXTURES. PLEASE SEE PHOTOMETRY SPEC SHEET FOR ADDITIONAL LUMEN DATA. * CALCULATIONS FOR LED FIXTURES ARE BASED ON MEASUREMENTS THAT COMPLY WITH IES LM-80 TESTING PROCEDURES AND IES TM-21 CALCULATOR ELECTRICAL POWER FACTOR 4W, 6W, 8W, 10W, 12W >0.9, 2W<0.9 STARTUP TEMPERATURE -40˚F TO 122˚F (-40˚C TO 50˚C) OPERATING VOLTAGE MULTIVOLT: 110-277VAC, 50/60 Hz OPERATING TEMPERATURE -40˚F TO 122˚F (-40˚C TO 50˚C) DRIVER INTEGRAL TO FIXTURE; DE-RATED POWER AND SYNCHRONOUS START-UP AT FULL BRIGHTNESS STORAGE TEMPERATURE -40˚F TO 176˚F (-40˚C TO 80˚C) MAX FIXTURE RUN LENGTH 2W/LF 4W/LF 6W/LF 8W/LF 10W/LF 12W/LF Volts Max Run all 1’ Max Run all 4’ Max Run all 1’ Max Run all 4’ Max Run all 1’ Max Run all 4’ Max Run all 1’ Max Run all 4’ Max Run all 1’ Max Run all 4’ Max Run all 1’ Max Run all 4’ 120 214 214 186 186 152 152 114 114 91 91 76 76 220 374 392 340 340 277 277 209 209 95 167 95 139 277 374 494 374 428 349 349 263 263 95 190 95 175 POWER CONSUMPTION 2W*/LF (6.6W/M) ; 4W/LF (13.2W/M) ; 6W/LF (19.8W/M) ; 8W/LF (26.4W/M) ; 10W/LF (33W/M) ; 12W/FL (39.6W/M) * 3W/LF (9.9W/M) at 220V -277V GRAZING 9 x 9 9 x 17 9 x 29 9 x 59 15 x 15 15 x 23 15 x 35 15 x 65 COVE 120** Asym LINE OF LIGHT LOL WASHING 25 x 25 25 x 33 25 x 45 25 x 75 39 x 9 55 x 25 40 x40 40 x 48 40 x 60 40 x 90 45 x 15 70 x 40 70 x 70 EXAMPLE: L50-I-48-10-27-90-MULT-15x65 *90 CRI not available in 2200K or 5000K **120 is only available with Exterior option. See L35 spec sheet for interior cove options. ***Red is not available in 12W or 10W. ****Green is not available in 12W. Luminaire Power Material/ Finish Beam Colour Accessories S D3 D7 D10 1050mA Input, Series Wired 6W 12VAC Input, Parallel Wired 2W 12VAC Input, Parallel Wired 4W 12VAC Input, Parallel Wired 6W COP SS SOLID COPPER STAINLESS STEEL 15 25 38 60 15º 25º 38º 60º 2 3 4 2700K 3000K 4000K LF CJK FROSTED LENS CABLE JOINT KIT SERIES, REMOTE DRIVER REQUIRED: Constant current driver Individual fixtures require 6vdc @ 1050mA maximum PRODUCT CONFIGURATION 12VAC INTEGRAL DRIVER: Hunza integrated plug and play driver (included) Input:9-15VAC. Output: 6vdc @ D3=350mA, D7=700mA, D10=1050mA (1050mA limited to ≤ 40ºC (104ºF) ambient temperature in stainless steel) Cat. No. FLDK/L PROJECT: TYPE: SOURCE: NOTES: PURELED SPECIFICATIONS Floor Lite Dark Lighter Specifications may change without notice. This document contains proprietary information of Hunza. Its receipt or possession does not convey an rights to reproduce or disclose its content. HUNZA FACTORY 130 Felton Mathew Ave Saint Johns Auckland 1072 New Zealand Ph: +64-9-528 9471 Fax: +64-9-528 9361 hunza@hunza.co.nz www.hunzalighting.com INTERNATIONAL CONTACTS: http://www.hunzalighting.com/contact.php Please fill in appropriate codes into boxes provided FLDK/L LED Chip Luminaire Output Lumens Per Watt CRI (3000K) Colour Temperatures Beam Angles Ingress Protection Cree XHP-50-2 Plug and Play field replaceable LED board 600 Lumens @ 1050mA (6 watts), 420 Lumens @ 700mA (4 watts), 240 Lumens @ 350mA (2 watts), delivered from luminaire with unobstructed beam. 100 Lumens @ 6 watts minimum, delivered from luminaire with unobstructed beam 90+ 2700K, 3000K, 4000K 15, 25, 38, 60 IP67 Electronics = 5 years Body Cop/SS = 10 yearsWarranty Standards AS/NZS 61046 cUL 1838, 2108 CSA C22.2 No.250.7, No.250.0-08 CE TLTM TILTING MODULE OTHER LAMP OPTIONS: FLDK/H - MR16 Halogen 12V Lamp FLDK/SL - MR16 LED Retrofit 12V Lamp (lamps vary by market - please refer to supplier for details) FLDK/GUH - GU10 120/240V Halogen Lamp (body length increases for all GU10 lamps) FLDK/GUSL - GU10 LED Retrofit 120/240V Lamp (lamps vary by market - please refer to supplier for details) Click here for halogen specification sheet Click here for 240v Remote Power Supply Guidance Charts Click here for USA Remote Power Supply Guidance Charts 63.5mm 2½” 88mm 3½” 130mm 5” 25mm 1” 3mm ⅛” 25mm 1” 76mm 3” 100mm 4” *canister included 203mm 8” L150 Specification Sheet | 2023-01-25 | pg.1MP Lighting © | www.mplighting.com | info@mplighting.com | 604.708.1184 Ordering Information Date :Quantity : Project :Note : Type : L150 EXTERIOR | INTERIOR Window Sill Wet, Damp, and Dry location Product Version CCT & CRI 1 Beam Angle Accessories 2 (optional) Trim Finish L150 2 E BA 2 2W W22S 2200K 80+ W27H 2700K 90+ W30H 3000K 90+ W35H 3500K 90+ W41H 4100K 90+ E elliptical 10°+170°S barn door shields BA black anodized System Components (Ordered Separately) Remote Driver :* Consult MP Lighting Website or Factory. Clear Form Important Notes Specification 1. Refer to pg.2 - Electrical for Colour Consistency details. 2. Refer to Appendix or MP Lighting website for images and details. Specifications Luminaire | Example Code: L150-2-W30H-E-S-BA Warranty Notes & Disclaimer Malfunction and damage to product due to incompatible dimming system or misuse will not be covered under warranty. Consult MP Lighting for recommended drivers. If the fixture has an option to be installed with a dimming control system, consult a dimming system manufacturer with minimum load before installing. MP Lighting reserves the right, at its sole discretion, at any time and without notice, to make design changes to any of our products. Consult MP Lighting website for most updated documentation. Shown with no accessories Project: Fixture Type: Location: Contact/Phone: 1 of 4 1300 S. Wolf Road • Des Plaines, IL 60018 • Phone 1-800-705-SERV (7378) • Visit us at www.acuitybrands.com/juno-recessed Printed in U.S.A. ©2015-2020 Acuity Brands Lighting, Inc. Rev. 09/8/20 Light Commercial & Residential G1.10.4G2 2” IC 600 AND 1000 LUMENS LED ROUND DOWNLIGHT CONE 2LEDTRIM G2 DC PRODUCT DESCRIPTION 2 inch aperture recessed downlight is IC rated for insulated or non-insulated applications • Luminaire produces up to 1000 lumens and is available with optical distributions approximating that of 75W MR16 halogen lamps • Low profile form factor allows luminaire to fit in 2 x 6 construction • Designed to provide 50,000 hours of life • 5 year limited warranty on LED Components. ENVIRONMENTALLY FRIENDLY, ENERGY EFFICIENT • No harmful ultraviolet or infrared wavelengths • No lead or mercury, RoHS compliant • Comparable light output up to a 75W MR16 halogen lamp PRODUCT SPECIFICATIONS LED Light Engine Exceptional fixture to fixture color consistency within a 3-step MacAdam ellipse • 2700K, 3000K, 3500K, and 4000K color temperatures are available with 80 CRI or 90 CRI minimum. Modular Optics Available with field interchangeable optics in 18° Spot, 24° Narrow Flood, or 40° Flood distributions. Aesthetic Trim Trim features die cast beveled knife edge trim ring for clean ceiling interface available in white, black, satin nickel, or brushed bronze • Spun aluminum reflectors are available in clear, haze, wheat haze, black and white finishes. LED Driver Choice of dedicated 120 volt (120) driver or universal voltage (MVOLT) driver that accommodates input voltages from 120-277 volts AC at 50/60Hz • Power factor > 0.9 • Dedicated 120 volt driver (120) is dimmable with the use of most incandescent, magnetic low voltage and electronic low voltage dimmers • Universal voltage driver (MVOLT) is dimmable with the use of most 0-10V protocol dimmers • For a list of compatible dimmers, see JUNO2ING2-DIM. Life Rated for 50,000 hours at 70% lumen maintenance. Labels ENERGY STAR® Certified • 90CRI fixtures are certified to the high efficacy requirements of California T24 JA8-2016 • Meets energy code Air Leakage requirements per ASTM E283 • UL and cUL listed for wet locations • 2NCHSG option is compatible with spray foam insulation with an R-value of 3.2 per inch or less. Junction Box Includes (2) ½” knock-outs equipped with pryout slots • Push-in electrical connectors for field connections. Mounting Remodel style plaster frame installs from below the ceiling and accommodates ceiling thicknesses from ½” to 1” • For thicker ceilings up to 1 ½”, order 2JCTA150 • New Construction mounting frame, 2NCMF, is also available with Patented (US Patent D552,969) Real Nail 3® telescoping bar hangers to position fixture and locate wiring prior to ceiling installation • Recommend a minimum of 5.5” cavity depth to install properly • Flexible supply is recommended and non-flexible supply requires top access. Real Nail 3 Bar Hangers 2NCHSG new construction housing and new construction mounting frame, 2NCMF, available with telescoping Real Nail® 3 system which permits quick placement of housing anywhere within 24” O.C. joists or suspended ceilings • Includes removable nail for repositioning of fixture in wood joist construction • Integral T-bar notch and clip for suspended ceilings • Design covered under US Patent D552,969 • 2NCHSG requires 2x8 construction Specifications subject to change without notice. Downlight Cone Finishes HZSN BWH CWH WWH WHZBRZ HZWH BBL DIMENSIONS 11 9/16” 4 1/8” 3 1/8” 2 5/8” CEILING CUTOUT 2” APERTURE 7” ELECTRICAL DATA (600L) Dedicated 120V (120) Universal Voltage (MVOLT) Voltage 120 120 277 Input Power 7.5 (±5%)7.2 7.5 (±5%) Input Current .06 .06 .03 Frequency 50/60Hz 50/60Hz Power Factor >0.9 >0.9 >0.9 ELECTRICAL DATA (1000L) Dedicated 120V (120) Universal Voltage (MVOLT) Voltage 120 120 277 Input Power 11.5 (±5%)10.9 11.4 (±5%) Input Current .10 .09 .04 Frequency 50/60Hz 50/60Hz Power Factor >0.9 >0.9 >0.9 USAI LIGHTING HEADQUARTERS 1126 River Road New Windsor, NY 12553 T: 845–565–8500 F: 845–561–1130 info@usailighting.com USAI LIGHTING COLLABORATORY 13 Crosby Street New York, NY 10013 845-234-4090 showroom@usailighting.com © 2017. USAI, LLC. All rights reserved. All designs protected by copyright. Covered by US Patents: 8,581,520, 8,456,109, 10,443,822, D857,289 and D864,468. Patents pending. USAI, BeveLED BLOCK, Classic White and Warm Glow are registered trademarks of USAI, LLC. Keep ceiling height right where it is! Specifically designed to work with surface-mounted conduit and junction boxes, BeveLED BLOCK has a modern look that’s perfect for lofts, offices, and open architectural spaces. Also available with solid-sides styling shown above, Block also creates a finished look when recessed conduit is possible. FEATURES • High performance architectural lighting solution for industrial or exposed concrete ceiling types where recessed lighting is not an option • Convenient conduit cutouts provide access for surface-mounted conduit to pass through the luminaire • Smooth, modular solid and keyhole slots are interchangeable and user configurable to allow for simple on site customization in the field. • BeveLED BLOCK is available in a range of standard and custom colors to complement your project, whether an industrial or refined look is desired. • Industry leading illumination and craftsmanship SURFACE MOUNT CONDUIT CUT OUT usailighting.com/block BEVELED BLOCK DOWNLIGHT PERFORMANCE DATA Classic White Warm Glow Dimming LED COLOR CHOICES 9W 12W 16W 24W 16W Coloring Rendering Index: 80+ 90+ 80+ 90+ 80+ 90+ 80+ 90+ 80+ 90+ Source Lumens: 1150 900 1300 1025 1725 1350 2400 1875 1275 1025 Lumens Per Watt: 93 68 86 67 86 67 80 63 69 55 Delivered Lumens: 775 600 1025 800 1375 1075 1925 1500 1100 875 *Performance based on 3000K. See IES files for exact values at usailighting.com. DELIVERED* PERFORMANCE: Classic White Warm Glow Dimming 2700K 3000K 3500K 4000K 2700K 3000K Coloring Rendering Index: 80+ 90+ 80+ 90+ 80+ 90+ 80+ 90+ 80+ 90+ 80+ 90+ Multiplier for Lumen Output: 0.94 0.78 1.00 0.78 1.00 1.00 1.06 1.06 0.94 0.79 1.00 0.81 CORRELATED COLOR TEMPERTURE BeveLED Block - BLRD5 Round Downlight Created: 03/27/2023 Type: BEGA Product: Project: Voltage: Color: Options: Modified: BEGA 1000 BEGA Way, Carpinteria, CA 93013 (805) 684-0533 FAX (805 ) 566 -9474 www .bega -us .com ©copyright BEGA 2017 Updated 02/17 Post construction: One piece extruded aluminum. All aluminum in the construction is marine grade and copper free. Lamp Enclosure: One piece die cast aluminum housing attached to post using two (2) captive stainless steel screws threaded into stainless steel inserts. Matte safety glass lens. Fully gasketed using a one piece molded silicone gasket. Electrical: 2.1W LED luminaire, 3.4 total system watts, -30°C start temperature. Integral 12V AC driver provided must be operated using remote magnetic transformer. Standard LED color temperature is 3000K with a >90 CRI. Note: LEDs supplied with luminaire. Due to the dynamic nature of LED technology, LED luminaire data on this sheet is subject to change at the discretion of BEGA-US. For the most current technical data, please refer to www.bega-us.com. Anchor base: Anchor base made of galvanized steel, made for bolting into foundation or other paved surface. Bollards are secured to anchor base using two (2) stainless steel set screws. Finish: Available in four standard BEGA colors: Black (BLK); White (WHT); Bronze (BRZ); Silver (SLV). To specify, add appropriate suffix to catalog number. Custom colors supplied on special order. Please note: BEGA’s approach to product design is to innovate, not follow. With a steadfast commitment to quality, each product is conceived to satisfy a general or specific lighting task as defined by its architectural or exterior surroundings. The Home and Garden Collection is designed specifically for use in Residential and Light Commercial applications. Please reference our standard BEGA portfolio when mounting provisions for the rigorous demands of high-use commercial and/or vandal prone settings are required. CSA certified to U.S. and Canadian standards, suitable for wet locations. Protection class IP65 Weight: 6.3 lbs. LED garden and pathway bollard Lamp A B C 77 264 with hardscape base 2.1 W LED 4 3⁄8 27 1⁄2 4 3⁄8 PowerLuminaire Material/ Finish AccessoriesColour TL/L S D3 D7 D10 EBK EBZ EOGR EWH EWB EDG ESTAR COP SS BLACK BRONZE OLIVE GREEN WHITE WHITE BIRCH DARK GREY SILVER STAR SOLID COPPER STAINLESS STEEL 2 3 4 2700K 3000K 4000K SSP/G FM SUPER SPIKE CJK FLANGE MOUNT CABLE JOINT KIT PRODUCT CONFIGURATION ECT CORTEN Cat. No. TL/L PROJECT: TYPE: SOURCE: NOTES: LED Chip Luminaire Output Lumens Per Watt CRI (3000K) Colour Temperatures Beam Angles Ingress Protection Cree XHP-50-2 Plug and Play field replaceable LED board 510 Lumens @ 1050mA (6 watts), 340 Lumens @ 700mA (4 watts), 160 Lumens @ 350mA (2 watts), delivered from luminaire with unobstructed beam. 85 Lumens minimum @ 6 watts, delivered from luminaire with unobstructed beam 90+ 2700K, 3000K, 4000K 360 degrees IP56/IP66 PURELED SPECIFICATIONS Electronics = 5 years Body Cop/ SS = 10 years Body Aluminium = 5 years Warranty Standards AS/NZS 61046 cUL 1838, 2108 CSA C22.2 No.250.7, No.250.0-08 CE Tier Lite Specifications may change without notice. This document contains proprietary information of Hunza. Its receipt or possession does not convey an rights to reproduce or disclose its content. HUNZA FACTORY 130 Felton Mathew Ave Saint Johns Auckland 1072 New Zealand Ph: +64-9-528 9471 Fax: +64-9-528 9361 hunza@hunza.co.nz www.hunzalighting.com INTERNATIONAL CONTACTS: http://www.hunzalighting.com/contact.php Please fill in appropriate codes into boxes provided BOLOP OPAQUE LENS Beam 360 360º OTHER LAMP OPTIONS: TL/H - MR16 Halogen 12V Lamp TL/SL - MR16 LED Retrofit 12V Lamp (lamps vary by market - please refer to supplier for details) TL/GUH - GU10 120/240V Halogen Lamp (body length increases for all GU10 lamps) TL/GUSL - GU10 LED Retrofit 120/240V Lamp (lamps vary by market - please refer to supplier for details) Click here for halogen specification sheet Click here for 240v Remote Power Supply Guidance Charts Click here for USA Remote Power Supply Guidance Charts SERIES, REMOTE DRIVER REQUIRED: Constant current driver Individual fixtures require 6vdc@1050mA maximum 12VAC INTEGRAL DRIVER: Hunza integrated plug and play driver(included) Input: 9-15VAC, 7watt total Output:6vdc @ D3=350mA, D7=700mA, D10=1050mA (1050mA limited to ≤40ºC (104ºF) ambient temperature in stainless steel) 110/240VAC RETRO DRIVER: Input: 120/240vac, 5 watt total (included) Output: 6vdc, 700mA (non dimming) 24VDC DRIVER: Input: 24vdc. Output: 18vdc @ 700mA constant current (non dimming). Note: not for USA. 38 1½” 1050mA Input, Series Wired 6W 12VAC Input, Parallel Wired 2W 12VAC Input, Parallel Wired 4W 12VAC Input, Parallel Wired 6W D24 24VDC Input, Parallel Wired R 110/240V Input, Retro, Parallel Wired 6W Cheshire Tall 3/4 Wall Lantern Designer: Chapman & Myers Item # CHO 2607AI-CG Height: 27.75" Width: 7.5" Extension: 6.5" Backplate: 5.75" x 24.75" Rectangle Finishes: AI Glass Options: CG Socket: E26 Keyless Wattage: 40 T10 Weight: 14 Pounds 8531701EN3-10: Small One Light Outdoor Wall Lantern Collection: Pohl Crafted from steel. Dark Sky and Wildlife compliant Assortment includes: 7"small -, 9"medium one light wall lantern, 14"two- light medium and 18 1/2" large wall lantern Three finish options available: Black, Bronze and Painted Brushed Nickel Easily converts to LED with optional replacement lamps Wet Rated UPC #:785652080838 Finish: Bronze (10) Dimensions: Width:5.0" Height:7.0" Weight:2.46 lbs. Extends:7.75' Wire:6.5" (color;Black/White) Mounting Proc.:Screw(s) Connection:Mounted To Box Watts:9 Lumens:800 Bulbs: 1 - LEDMedium A19 9.0w Max. 120v included Features: ENERGY STAR® Qualified Dark sky friendly. Designed to emit no light above the 90° horizontal plane. Photometry unavailable. LED Bulbs are an efficient, versatile and durable light source that deliver exceptional performance. Powder coat added to the finish to protect against aging. Meets Title 24 energy efficiency standards Title 24 compliant when used with included Joint Appendix (JA8) approved lamp. Material List: 1 Body - Aluminum - Bronze Safety Listing: Safety Listed for Wet Locations Instruction Sheets: Trilingual (English, Spanish, and French) (990W8_3170_-POH) Backplate / Canopy Details: Type Height / Length Width Depth Diameter Outlet Box Up Outlet Box Down Back Plate 7.0 5.0 2.75 3.5 Replacement Bulb Data: Product # Type Base Watts Watts Consumed Volts Hours Lumens Temp (°K) CRI Shipping Information: Package Type Product #Quantity UPC Length Width Height Cube Weight Frt. Class UPS Ship Individual 8531701-12 1 785652080838 10.5 9.75 7.75 0.46 3.3 125 Yes Master Pack 8531701EN3-10 6 10785652080835 25.5 10.9 20.0 3.22 22.2 125 Yes NJ Pallet 144 48.0 40.0 71.0 78.89 475.2 No NV Pallet 144 48.0 40.0 71.0 78.89 475.2 No Visual Comfort & Co. reserves the right to revise the design of components of any product due to parts availability or change in safety listing standards without assuming any obligation or liability to modify any products previously manufactured and without notice. This literature depicts a product design that is the sole and exclusive property of Visual Comfort & Co.. In compliance with U.S copyright and patent requirements, notification is hereby presented in this form that this literature, or the product it depicts, is not to be copied, altered or used in any manner without the express written consent of, or contrary to the best interests of Visual Comfort & Co.