HomeMy WebLinkAbout20220842 Final Details Admin Action Decision
Tamie Ehinger,
Rob DuBoff,
C ITY OF S ARATOGA S PRINGS
Chris Bennett
Leslie DiCarlo
D ESIGN R EVIEW B OARD
Jeff Gritsavage
Tad Roemer
Ellen Sheehan
City Hall - 474 Broadway
Karen Cavotta,
Saratoga Springs, New York 12866
Tel: 518-587-3550 x.2517
www.saratoga-springs.org
NOTICE OF
ADMINISTRATIVE ACTION
In the matter of the request for administrative action relating to application
#20220842
15 Marion Pl Final Details
15 Marion Place
Saratoga Springs, New York 12866
to approve the final details as shown on the attached plans.
The Chairperson of the Design Review Commission finds that, in accordance with Section 8.3 of the
Rules and Regulations of the Design Review Commission, the requested action is not substantive in
nature and is not contrary to the intent of the original Commission decision. Therefore, the request for
administrative action, as described above, is approved.
April 17, 2023
Date Chair
cc: Building Department File
(Applicant)
(Agent)
PROPOSED
FRONT ELEVATION
NOTE: ACTUAL DIMENSIONS MAY VARY SLIGHLTY. CONTRACTORIS RESPONSIBLE FOR VERIFYING ALL MEASUREMENTS PRIOR TOCONSTRUCTION AND TO NOTIFY DESIGN ENGINEER IMMEDIATELYOF ANY/ALL DISCREPANCIES
FOR DETERMINATION.
EXISTING PORCH
REMAINS UNCHANGED
(NOT FULLY DEPICTED)
WOOD SIDING TO
(REPAIR AS NEC)
MATCH EX HOUSE
TRIM REMAINS
NEW WOOD TRIM
EXISTING ROOF
TRIM / SILL REMAINS
(REPAIR AS NEC)REMAINS UNCHANGED
WOOD SIDING TO
REPAIR EXISTING TRIM
EXISTING PORCH ROOF
MATCH EX HOUSE
(TO MATCH EXISTING)
REMAINS UNCHANGED
NEW WOOD DH WINDOW
EXISTING PORCH ROOFREMAINS UNCHANGED
FJ UNKNOWN
FJ UNKNOWN
EXISTING
EXISTING
EXISTING WALLREMAINS UNCHANGED
LIVING ROOM
EXISTING CEILING HT
AS NEC TO LEVEL FLOOR
NEW SHEATHING & SHIMS
EXISTING ROOF REMAINS UNCHANGED
PRIMARY STE
PROPOSED
FJ UNKNOWN
EXISTING ATTIC
FRONT ELEVATION
(REMAINS UNCHANGED)
NEW
PORCH
CLOSET
NOTE: ACTUAL DIMENSIONS MAY VARY SLIGHLTY. CONTRACTORIS RESPONSIBLE FOR VERIFYING ALL MEASUREMENTS PRIOR TOCONSTRUCTION AND TO NOTIFY DESIGN ENGINEER IMMEDIATELYOF ANY/ALL DISCREPANCIES
FOR DETERMINATION.
EXISTING
1/ 2" GWB SECTION A
PROPOSED
NOTE: ACTUAL DIMENSIONS MAY VARY SLIGHLTY. CONTRACTORIS RESPONSIBLE FOR VERIFYING ALL MEASUREMENTS PRIOR TOCONSTRUCTION AND TO NOTIFY DESIGN ENGINEER IMMEDIATELYOF ANY/ALL DISCREPANCIES
FOR DETERMINATION.
EXISTING FJ REMAIN
R-38 FOAM INSUL
(R-24 MIN FOAM INSUL)
TRIM TO MATCH HOUSE
EXISTING PORCH
(OR REPAIR IN KIND)
TO MATCH HOUSE
NEW WOOD DH WINDOW &
NEW WOOD SIDING
REMAINS UNCHANGED
WITH R-21 FOAM INSUL
EXISTING PORCH ROOF
REMAINS UNCHANGEDNEW 2x6 CJ - 16"oc WITH
(NOT FULLY DEPICTED)
EXISTING PREVIOUS PORCH
PORCH ROOF REVEAL
REMAINS UNCHANGED
TRIM, SILL & CASING TO REMAIN
CONTINUE / REPAIR SILL TRIM
MATCH FRONT OF HOUSE TO
EXISTING & NEW 2x4 WALL - 16"oc
NEW "COLUMN" TRIM DETAIL TO
"FRAME OUT" PREVIOUS PORCH
NEW WOOD SIDING TO MATCH HOUSE
FINISHES REMAIN UNCHANGED
WOOD SIDING TO MATCH EX HOUSE
GABLE FRAMING, WINDOWS, TRIM &
EXISTING WALL REMAINS UNCHANGED
1/ 2" CDX PLY OR ADVANTECH SHEATHING
APPROX. 24" CLEAR
BY RES. CODE)
(21" MIN CLEAR REQ.
21" MIN CLEAR REQ.IN FRONT OF FIXTURE
ADDED TO WINDOWS
IMPACT FILM TO BE
6'-0"
"
EXISTING
STAIRS DN
2
EXISTING
STAIRS DN
1
12'-0NEW 2x4 WALLS
16"oc (TYP)
(REMAIN UNCHANGED)
(REMAIN UNCHANGED)
10'-1"
PROPOSED
SOAKING TUB
EXISTING
NEW EN-SUITE BATH
DRESSING AREA
WALK IN CLOSET
"
DN
2
DN
1
2-7
3'-8"
3'-4
2-6
2-6
2-8
2-8
IMPACT FILM TO BE
ADDED TO WINDOW
13'-0"
13'-0"
EXISTING
EXISTING
PROPOSED
EXISTING
(8'-5 CEILING HT)
PRIMARY BR
(8'-5 CEILING HT)
9'-1"
PRIMARY BR
9'-1"
SMOKE DETECTOR / ALARM(HARD WIRED TO ALL HOUSE ALARMS)
50 MIN CFM VENT FAN TO EXHAUST TO EXTERIORSMOKE & CARBON MONOXIDE DETECTOR / ALARM(HARD WIRED TO ALL HOUSE ALARMS)(REQ WITHIN 10' OF BEDROOM DOORS)
DOCUMENTED BY ENGINEERING AMERICA CO.60W EQUIVALENT LIGHT FIXTURE
TOWARDS STREET
UPPER FLOOR PLAN
TOWARDS STREET
UPPER FLOOR PLAN
NOTE: ACTUAL DIMENSIONS MAY VARY SLIGHLTY. CONTRACTORIS RESPONSIBLE FOR VERIFYING ALL MEASUREMENTS PRIOR TOCONSTRUCTION AND TO NOTIFY DESIGN ENGINEER IMMEDIATELYOF ANY/ALL DISCREPANCIES
FOR DETERMINATION.
NOTE: ACTUAL DIMENSIONS MAY VARY SLIGHLTY. CONTRACTORIS RESPONSIBLE FOR VERIFYING ALL MEASUREMENTS PRIOR TOCONSTRUCTION AND TO NOTIFY DESIGN ENGINEER IMMEDIATELYOF ANY/ALL DISCREPANCIES
FOR DETERMINATION.
3-0
3-0
FRAMED IN
WINDOW REMOVED &
EXISTING FRAMED WINDOW
A
2" UP
2'-9"
6'-7"
6'-7"
PORCH
EXISTING
ENCLOSED
(8'-9 CEILING HT)
A
EXISTING OPENING FRAMED
(2)2x6 HEADER REQ
FINISHED WITH WOOD SIDING
(3) EXISTING WINDOWS
PAINTED TO MATCH EX HOUSE
REPLACED WITH(1) NEW
WOOD DH WINDOW (CENTERED)
NEW CLOSET AREA
(2)2x6 HEADER REQ
MATCH EX HOUSE
REMOVED & FRAMED IN
2x4 WALLS WITH R-21
RETAIN PREVIOUS PORCH
(3)WINDOWS REMOVED &FRAMED IN WITH (1) NEW
CASING, SILL & TRIM ON SIDE &
FRONT WALLS WHEN WINDOWS
WINDOW CENTERED ON WALL
FOAM INSUL & WOOD SIDING TO