Loading...
HomeMy WebLinkAbout20220842 Final Details Admin Action Decision Tamie Ehinger, Rob DuBoff, C ITY OF S ARATOGA S PRINGS Chris Bennett Leslie DiCarlo D ESIGN R EVIEW B OARD Jeff Gritsavage Tad Roemer Ellen Sheehan City Hall - 474 Broadway Karen Cavotta, Saratoga Springs, New York 12866 Tel: 518-587-3550 x.2517 www.saratoga-springs.org NOTICE OF ADMINISTRATIVE ACTION In the matter of the request for administrative action relating to application #20220842 15 Marion Pl Final Details 15 Marion Place Saratoga Springs, New York 12866 to approve the final details as shown on the attached plans. The Chairperson of the Design Review Commission finds that, in accordance with Section 8.3 of the Rules and Regulations of the Design Review Commission, the requested action is not substantive in nature and is not contrary to the intent of the original Commission decision. Therefore, the request for administrative action, as described above, is approved. April 17, 2023 Date Chair cc: Building Department File (Applicant) (Agent) PROPOSED FRONT ELEVATION NOTE: ACTUAL DIMENSIONS MAY VARY SLIGHLTY. CONTRACTORIS RESPONSIBLE FOR VERIFYING ALL MEASUREMENTS PRIOR TOCONSTRUCTION AND TO NOTIFY DESIGN ENGINEER IMMEDIATELYOF ANY/ALL DISCREPANCIES FOR DETERMINATION. EXISTING PORCH REMAINS UNCHANGED (NOT FULLY DEPICTED) WOOD SIDING TO (REPAIR AS NEC) MATCH EX HOUSE TRIM REMAINS NEW WOOD TRIM EXISTING ROOF TRIM / SILL REMAINS (REPAIR AS NEC)REMAINS UNCHANGED WOOD SIDING TO REPAIR EXISTING TRIM EXISTING PORCH ROOF MATCH EX HOUSE (TO MATCH EXISTING) REMAINS UNCHANGED NEW WOOD DH WINDOW EXISTING PORCH ROOFREMAINS UNCHANGED FJ UNKNOWN FJ UNKNOWN EXISTING EXISTING EXISTING WALLREMAINS UNCHANGED LIVING ROOM EXISTING CEILING HT AS NEC TO LEVEL FLOOR NEW SHEATHING & SHIMS EXISTING ROOF REMAINS UNCHANGED PRIMARY STE PROPOSED FJ UNKNOWN EXISTING ATTIC FRONT ELEVATION (REMAINS UNCHANGED) NEW PORCH CLOSET NOTE: ACTUAL DIMENSIONS MAY VARY SLIGHLTY. CONTRACTORIS RESPONSIBLE FOR VERIFYING ALL MEASUREMENTS PRIOR TOCONSTRUCTION AND TO NOTIFY DESIGN ENGINEER IMMEDIATELYOF ANY/ALL DISCREPANCIES FOR DETERMINATION. EXISTING 1/ 2" GWB SECTION A PROPOSED NOTE: ACTUAL DIMENSIONS MAY VARY SLIGHLTY. CONTRACTORIS RESPONSIBLE FOR VERIFYING ALL MEASUREMENTS PRIOR TOCONSTRUCTION AND TO NOTIFY DESIGN ENGINEER IMMEDIATELYOF ANY/ALL DISCREPANCIES FOR DETERMINATION. EXISTING FJ REMAIN R-38 FOAM INSUL (R-24 MIN FOAM INSUL) TRIM TO MATCH HOUSE EXISTING PORCH (OR REPAIR IN KIND) TO MATCH HOUSE NEW WOOD DH WINDOW & NEW WOOD SIDING REMAINS UNCHANGED WITH R-21 FOAM INSUL EXISTING PORCH ROOF REMAINS UNCHANGEDNEW 2x6 CJ - 16"oc WITH (NOT FULLY DEPICTED) EXISTING PREVIOUS PORCH PORCH ROOF REVEAL REMAINS UNCHANGED TRIM, SILL & CASING TO REMAIN CONTINUE / REPAIR SILL TRIM MATCH FRONT OF HOUSE TO EXISTING & NEW 2x4 WALL - 16"oc NEW "COLUMN" TRIM DETAIL TO "FRAME OUT" PREVIOUS PORCH NEW WOOD SIDING TO MATCH HOUSE FINISHES REMAIN UNCHANGED WOOD SIDING TO MATCH EX HOUSE GABLE FRAMING, WINDOWS, TRIM & EXISTING WALL REMAINS UNCHANGED 1/ 2" CDX PLY OR ADVANTECH SHEATHING APPROX. 24" CLEAR BY RES. CODE) (21" MIN CLEAR REQ. 21" MIN CLEAR REQ.IN FRONT OF FIXTURE ADDED TO WINDOWS IMPACT FILM TO BE 6'-0" " EXISTING STAIRS DN 2 EXISTING STAIRS DN 1 12'-0NEW 2x4 WALLS 16"oc (TYP) (REMAIN UNCHANGED) (REMAIN UNCHANGED) 10'-1" PROPOSED SOAKING TUB EXISTING NEW EN-SUITE BATH DRESSING AREA WALK IN CLOSET " DN 2 DN 1 2-7 3'-8" 3'-4 2-6 2-6 2-8 2-8 IMPACT FILM TO BE ADDED TO WINDOW 13'-0" 13'-0" EXISTING EXISTING PROPOSED EXISTING (8'-5 CEILING HT) PRIMARY BR (8'-5 CEILING HT) 9'-1" PRIMARY BR 9'-1" SMOKE DETECTOR / ALARM(HARD WIRED TO ALL HOUSE ALARMS) 50 MIN CFM VENT FAN TO EXHAUST TO EXTERIORSMOKE & CARBON MONOXIDE DETECTOR / ALARM(HARD WIRED TO ALL HOUSE ALARMS)(REQ WITHIN 10' OF BEDROOM DOORS) DOCUMENTED BY ENGINEERING AMERICA CO.60W EQUIVALENT LIGHT FIXTURE TOWARDS STREET UPPER FLOOR PLAN TOWARDS STREET UPPER FLOOR PLAN NOTE: ACTUAL DIMENSIONS MAY VARY SLIGHLTY. CONTRACTORIS RESPONSIBLE FOR VERIFYING ALL MEASUREMENTS PRIOR TOCONSTRUCTION AND TO NOTIFY DESIGN ENGINEER IMMEDIATELYOF ANY/ALL DISCREPANCIES FOR DETERMINATION. NOTE: ACTUAL DIMENSIONS MAY VARY SLIGHLTY. CONTRACTORIS RESPONSIBLE FOR VERIFYING ALL MEASUREMENTS PRIOR TOCONSTRUCTION AND TO NOTIFY DESIGN ENGINEER IMMEDIATELYOF ANY/ALL DISCREPANCIES FOR DETERMINATION. 3-0 3-0 FRAMED IN WINDOW REMOVED & EXISTING FRAMED WINDOW A 2" UP 2'-9" 6'-7" 6'-7" PORCH EXISTING ENCLOSED (8'-9 CEILING HT) A EXISTING OPENING FRAMED (2)2x6 HEADER REQ FINISHED WITH WOOD SIDING (3) EXISTING WINDOWS PAINTED TO MATCH EX HOUSE REPLACED WITH(1) NEW WOOD DH WINDOW (CENTERED) NEW CLOSET AREA (2)2x6 HEADER REQ MATCH EX HOUSE REMOVED & FRAMED IN 2x4 WALLS WITH R-21 RETAIN PREVIOUS PORCH (3)WINDOWS REMOVED &FRAMED IN WITH (1) NEW CASING, SILL & TRIM ON SIDE & FRONT WALLS WHEN WINDOWS WINDOW CENTERED ON WALL FOAM INSUL & WOOD SIDING TO