Loading...
HomeMy WebLinkAbout20221079 313 Jefferson Final Subdivision Tree PlantingSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSAN SANSANSANSANSANSANSANSANSANSANSANSANSANSAN TSC (3) TSC (2) PG (1) PG (3) OV (1)BN (1)TC (1) AP (2) RM (17) VA (6) RM (15) RM (12) PROPOSED RESIDENCE TAYLOR STREET TC (1)TC (1)BN (1)OV (1)JEFFERSON STREETPROPOSED SUBDIVISION LINE PROPOSED DRIVEWAY EX. DECK EX. PATIO EXISTING RESIDENCE EXISTING NORWAY MAPLE TO BE REMOVED (DAMAGED). REPLACE WITH NEW NORWAY MAPLE 2 12"-3" CAL. NEW 6" PVC SANITARY SEWER CONNECTION NEW 1" COPPER LINE WATER CONNECTION EXISTING ELECTRIC EXISTING STORM PROPERTY LINE EXISTING TREE TO REMAIN PROPERTY LINE SETBACK PROPOSED SHRUBS/ GROUNDCOVER PROPOSED TREES SAVE DATE: 4/5/2023 8:39 AMFILE NAME: Z:\Projects\2022 Projects\22020 - Famosi Residence\DWG\03 SHEETS\22020_PLANTING PLAN.dwgPLOTTED BY:KCATELLIERDESIGN BY:DRAWN BY:CHECKED BY:############PLANTING PLAN L-1.10 1 LEGEND: DRAWING NO. PROJECT NO. PROJECT DRAWING TITLE DATE: REVISIONS DATE DESCRIPTION IT IS A VIOLATION OF NEW YORK STATE EDUCATION LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT, OR LAND SURVEYOR, TO ALTER ANY ITEM IN ANY WAY. IF AN ITEM BEARING THE STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING LICENSED PROFESSIONAL SHALL STAMP THE DOCUMENT AND INCLUDE THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERNATION, AND SPECIFIC DESCRIPTION OF THE ALTERATION. 04/04/2023 22020 FAMOSI RESIDENCE JOHN AND LINDA FAMOSI DRAWINGS NOT FOR CONSTRUCTION DWG OF PREPARED FOR DIG SAFE NOTE: THIS PLAN SET WAS DRAFTED WITHOUT THE BENEFIT OF "DIG SAFE" MARKINGS. UTILITIES SHOWN ARE NOT WARRANTED TO BE EXACT OR COMPLETE. THE CONTRACTOR SHALL CONTACT "DIG SAFE" AT 811 BEFORE COMMENCING ANY WORK AND SHALL PRESERVE EXISTING UTILITIES WHICH ARE NOT SPECIFIED TO BE REMOVED IN THIS PLAN SET. 38 High Rock Ave, Suite 3 | PO Box 272 Saratoga Springs, NY12866 518.450.4030 TRUST| QUALITY  COLLABORATION | INNOVATION on 24" x 36" sheet GRAPHIC SCALE 5 10 20010 1 inch = 10 feet north PLANTING SCHEDULE KEY QTY SCIENTIFIC NAME COMMON NAME SIZE COMMENTS TREES TSC PG TC OV BN AP SHRUBS 1 PLANT SCHEDULE SCALE: N.T.S. PLANTING NOTES: 1.ALL PLANT BEDS TO BE MULCHED WITH 4" DEEP BROWN HARDWOOD MULCH, UNLESS OTHERWISE NOTED ON THE PLANS. 2.PRIOR TO PLANTING, CONTRACTOR SHALL LOCATE, VERIFY, AND REPORT ANY CONFLICTS OF EXISTING UTILITY LINES TO THE LANDSCAPE ARCHITECT. 3.ALL NEW PLANT MATERIAL SHALL CONFORM TO THE MINIMAL GUIDELINES ESTABLISHED BY THE AMERICAN STANDARD FOR NURSERY STOCK PUBLISHED BY THE AMERICAN ASSOCIATION OF NURSERYMEN, INC. AND SHALL BE OF SPECIMEN QUALITY UNLESS APPROVED OTHERWISE BY DIRECTOR'S REPRESENTATIVE. 4.WRITTEN APPROVAL IS REQUIRED FROM LANDSCAPE ARCHITECT OF ANY PROPOSED SUBSTITUTIONS OF PLANT MATERIAL. CHANGED PLANTS SHALL BE EQUIVALENT FORM, HEIGHT, FLOWER, COLOR, LEAF, SIZE, BRANCHING, CULTURE AND FRUIT. 5.A MINIMUM OF 6” OF SUITABLE TOPSOIL IS REQUIRED IN AREAS WITH PROPOSED LAWN SEEDING PRIOR TO SEEDING. 6.PRIOR TO COMMENCEMENT OF PLANTING, STAKE LOCATION OF ALL PLANTINGS FOR APPROVAL BY LANDSCAPE ARCHITECT. 7.SCHEDULE DELIVERY OF PLANTS ONLY IN REASONABLE TIME AS TO WHEN THEY CAN BE INSTALLED. PLANTS TO BE INSPECTED BY LANDSCAPE ARCHITECT AT DELIVERY. 8.MAINTENANCE TO BEGIN IMMEDIATELY FOLLOWING INSTALLATION OF PLANT MATERIALS AND LAWN UNTIL FINAL ACCEPTANCE. 9.TREES SHALL NOT BE PLANTED BEFORE ACCEPTANCE OF ROUGH GRADING. TREES SHALL BE PLANTED 3” HIGHER THAN PREVIOUS GRADE. SHRUBS AND GROUND COVER SHALL BE PLANTED AS THE SAME RELATIONSHIP TO GRADE AS PREVIOUS GRADE. 10.PLANT MATERIAL QUANTITIES TO BE PROVIDED BY CONTRACTOR AS SHOWN ON DRAWINGS. 11.UNLESS NOTED ON PLANT LIST, PLANTS TO BE BALLED AND BURLAPPED OR CONTAINER GROWN. 12.FOR SEEDING OF DISTURBED AREAS USE SPECIFIED MIX FOR DESIGNATED AREA OR APPROVED EQUAL APPROVED BY LANDSCAPE ARCHITECT. 2' TYP.1'NOTES: 1.TREES SHALL BEAR SAME RELATIONSHIP TO FINISH GRADE AS IN THE NURSERY. 2.NEVER CUT A LEADER 3.TREES SHALL BE PLUMB & STRAIGHT. INSTALL 3 GUYS PER TREE EQUALLY SPACED AROUND ROOTBALL. ATTACH 18" GALV. STEEL CABLES @ 23 HEIGHT OF TREE. PROVIDE REINFORCED RUBBER HOSE TO ENCASE CABLE AROUND TRUNK. SECURE ALL ENDS OF CABLE W/ GALV. CLAMPS. 4" GALV. TRUNBUCKLE EA. CABLE 3"Ø X 2'-0" CEDAR STAKES, 3 PER TREE, DRIVEN IN AT A 25° ANBLE; STAKES TO BE OUTSIDE OF TREE PIT. 3" HT. PLANTING MIX SAUCER 3" DEPTH SHREDDED CEDAR MULCH (NATURAL COLOR); PULL MULCH AWAY FROM TREE TRUNK AMENDED PLANTING MIX, COMPACTED CUT ROPE SURROUNDING BOTTOM OF TREE TRUNK AFTER BACKFILLING BUT BEFORE MULCHING. DO NOT REMOVE BURLAP. NATIVE SOIL DRAINAGE MOUND, COMPACTED TO 92% UNDISTURBED SUBGRADE F.G. 2 EVERGREEN TREE PLANTING DETAIL SCALE: N.T.S. F.G. 2' TYP.1'NOTES: 1.TREES SHALL BEAR SAME RELATIONSHIP TO FINISH GRADE AS IN THE NURSERY. 2.THIN BRANCHES & FOLIAGE AS DIRECTED WHILE RETAINING NORMAL SHAPE OF TREE. NEVER CUT A LEADER 3.TREES SHALL BE PLUMB & STRAIGHT. ATTACH 18" GALV. STEEL CABLE TO STAKE. NOTCH STAKE TO RECEIVE CABLE. ENCASE WIRE AROUND TRUNK TO REINFORCE RUBBER HOSE ABOVE FIRST BRANCH. SECURE ALL ENDS OF CABLE WITH GALV. CLAMPS. 4" GALV. TURNBUCKLE EA. CABLE 3"Ø X 8' CEDAR STAKES, 3 PER TREE. STAKES TO BE SAME HEIGHT, DRIVEN IN ON A SLIGHT ANGLE. STAKES TO BE OUTSIDE OF ROOT BALL. WRAP ALL DECIDUOUS TRUNKS NEATLY TO A HEIGHT OF THE SECOND LOWEST BRANCH ( FALL PLANTING ONLY) 3" HT. PLANTING MIX SAUCER 3" DEPTH PINE BARK MULCH; PULL MULCH AWAY FROM TREE TRUNK AMENDED PLANTING MIX, COMPCTED CUT ROPE SURROUNDING BOTTOM OF TREE TRUNK AFTER BACKFILLING BUT BEFORE MULCHING. DO NOT REMOVE BURLAP. NATIVE SOIL DRAINAGE MOUND, COMPACTED TO 92% UNDISTURBED SUBGRADE 3 DECIDUOUS TREE PLANTING DETAIL SCALE: N.T.S. 6" MIN.6"4"3" SHREDDED HARDWOOD BARK MULCH OR 3" RIVER ROCK MULCH, SEE PLANS FOR SPECIFIED RIVER ROCK AREAS 3" MULCH OVER 3" LIP OF TOPSOIL TO FORM SAUCER CUT AND REMOVE BURLAP FROM TOP ONE THIRD OF SHRUB BALL 50% ORGANIC SOIL, 50% EXISTING SOIL MIX SCARIFY COMPACTED SUB-SOIL TO A DEPTH OF 4" 4 BALLED & BURLAPPED (B&B) DETAIL SCALE: N.T.S. DIG HOLE 2X DIAMETER OF B7B ROOT BALL OR CONTAINER