Loading...
HomeMy WebLinkAbout20190715 Smith Solar Panels Inverter ci) solar - • • --- cc iliSingle Phase Inverter with H B-Wave Technolo DC for North America I I I SE3000H-US I SE3800H-US I SE5000H-US/ SE6000H-US/ SE7600H-US/SE10000H-US/ SE1 1400H-US 4.111111111111111_— 0 solar= IlllEllllll HD,yi_., 63 6 a solar= ii,.,,..11D.,— ��'V.�A'u`1;. vrverta, L Vi.45 warrant .aaliaON •Power q •Fault •Pawer •Comm •Fault 4) h A , UK 0 - _, S a 4 titi 1r iira9 4 0 Optimized installation with HD-Wave technology • Specifically designed to work with power optimizers • Record-breaking efficiency • Fixed voltage inverter for longer strings • Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 ▪ UL1741 SA certified,for CPUC Rule 21 grid compliance • Extremely small — High reliability without any electrolytic capacitors vin — Built-in module-level monitoring m11111mil mi•• — Outdoor and indoor installation \VaVe — Optional: Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) www.solaredge.us SinglePhaseinverter with HD-Wave Technology for North America SE3000H-US/ SE3800H-US/ SE3000H-US / SE6000H-US/ SE7600H-US/ SE10000H-US/ SE11400H-US I SE3000H-US I SE3800H-US I SE5000H-US I SE6000H-US I SE7600H-US I SE10000H-US I SE11400H-US OUTPUT 3800 @ 240V 6000 @ 240V Rated AC Power Output 3000 3300 208V 5000 5000 208V 7600 10000 11400 VA 3800 @ 240V 6000 @ 240V Max.AC Power Output 3000 5000 7600 10000 11400 VA 3300 p 208V 5000 208V AC Output Voltage Min.-Nom.-Max. - ✓ _ ✓ _ _ - Vac (183-208-229) _ AC Output Voltage Min.-Nom.-Max. ✓ / / / V V V Vac (211-240-264) AC Frequency(Nominal) 59.3-60-60.5(1) Hz Maximum Continuous Output Current - 16 - 24 - - - A 208V Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A c240V GFDI Threshold 1 A Utility Monitoring,Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 1 5900 1 7750 1 9300 11800 1 15500 1 17650 W Maximum DC Power @208V ....5100 - 7750 - - - Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V - 9 - 13.5 - - - Maximum Input Current @240V 8.5 10.5 13.5 16.5 20 27 30.5 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600LSensitivity Maximum Inverter Efficiency 99 I 99.2 CEC Weighted Efficiency 99 Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional(2) Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 3/4"minimum/14-6 AWG 3/4"minimum/14-4 AWG DC Input Conduit Size/#of Strings/ „ 3/4”minimum/1-3 strings/ AWG Range 3/4 minimum/1-2 strings/14-6 AWG 14-6 AWG 21.3x 14.6x7.3/540x370 Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 x 185 in/mm Weight with Safety Switch 22/10 I 25.1/11.4 I 26.2/11.9 38.8/17.6 lb/kg Noise <25 <50 dBA Cooling Natural Convection Natural convection Operating Temperature Range -13 to+140/-25 to+603}(-40°F/-40°C option)141 °F/°C Protection Rating NEMA 3R(Inverter with Safety Switch) (1)For other regional settings please contact SolarEdge support (2)Revenue grade inverter P/N:SExxxxH-US000NNC2 (3)For power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf (4)-40 version P/N:SExxxxH-US000NNU4 ETA H S ,SrEa Rn ©SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:07/2018/V01/ENG NAM.Subject to change without notice.