Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20190715 Smith Solar Panels Specs
powered by Q.ANTUM /DUO/ \II_A_-.„7„,:E_--._-__---_,-„_---_-._..,_-,--3--_-,i,-_—.L_,._.__-,=,_--_--„---„:-„,--_,f.a,7--,-,.,_,-:__-_„\,-—;-,--- -_,-_.1,.1._,-,7-,7--..E--_.-_:_:_._=.._--:_\,,- Via. 1 1\ :_;-_-_-„,-',_,_- •. -_yam- _, - �� � :rte ____,__,..„. __ ! iO:1 \ -F :-17-177---:._ . -° .\P A _,_-_---: ___.,_ ____7___3 4., 1 , i _ __ ,_. ., u i _ _ _ _ _ _ _ ____ _____ ....._ __ ____ ____ _________. -_,_,__,._: =:_._._, „,_,____ __________ ____ _ , _,..„___ , ..„._____„: :___,,,__ „_____,,_„_, ,._.,_ ___„. „ :.:_._,;.. .. ,. .,..ii,„_,.;_ _....____.,.. ,....., __......., ____ ___ _ _ _._ .______ _ __ .._ _ __ __ _ __________ _____ Q.ANTU SOLAR MODULE ...... - - The new Q.PEAK DUO-Gb solar module from Q CELLS impresses thanks iL-7—' .VIir1.g to innovative Q.ANTUM DUO Technology, which enables particularly high performance on a small surface. Q.ANTUM's world-record-holding g cell concept has now been combined with state-of-the-art circuitry half cells and a six-busbar design, thus achieving outstanding performance under II"Illliuiial real conditions - both with low-intensity solar radiation as well as onIIIIIIIIM! hot clear summer days. MM il _. I= m GQ.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY ''J Higher yield per surface area, lower BOS costs, higher power ' classes, and an efficiency rate of up to 19.9%. L. t& INNOVATIVE ALL-WEATHER TECHNOLOGY F ill Optimal yields, whatever the weather with excellent low-light MUM wiffmnand temperature behavior. ird ENDURING HUM PERFORMANCE di Long-term yield security with Anti LID and Anti PID Technology', EUPD RESEARCH QCELLS YIELD SECURITY Hot-Spot Protect and Traceable Quality Tra.QTM. TOP BRAND PV ANTI PID TECHNOLOGY MODULES i (APT) EUROPE 1HOT-SPOT PROTECT 0 Ls EXTREME WEATHER RATING (HSP) �' High-tech aluminum alloy frame, certified for high snow `TRA•QTM, /ANTI LID TECHNOLOGY (5400 Pa) and wind loads (4000 Pa) regarding IEC. �0 1 7 TRACEABLE QUALITY (ALT) 0 A RELIABLE INVESTMENT VSE Inclusive 12-year product warranty and 25-year Quality Teste *Ad o I i near performance guarantee2. ,/high reliability yl ✓low degradation ✓frequent product surveillance • STATE OF THE ART MODULE TECHNOLOGY ID.40032587 Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. 1 APT test conditions according to IEC/TS 62804-1:2015, method B(-1500V, 168h) 2 See data sheet on rear for further THE IDEAL SOLUTION FOR: information. Rooftop arrays on Rooftop arrays on A-: residential buildings %1 commercial/industrial `1' buildings Engineered in Germany CELLS MECHANICAL SPECIFICATION Format 66.3 in x 39.4 in x 1.26 in(including frame) (1685mm x 1000 mm x 32mm) 1685mm 980 mm 352.5mm Weight 41.2 lbs(18.7 kg) - . ,c Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with anti-reflection technology E. „, Rahmen Back Cover Composite film 951mm Frame Black anodized aluminum 1DDDmm Cell 6 x 20 monocrystalline Q.ANTUM solar half-cells Junction box 2.76-3.35 in x 1.97-2.76 in x 0.51-0.83 in ` (70-85mm x 50-70mm x 13-21 mm) decentralized, IP67 8x Enlwasserungslocher s 4 x Befestigungspunkte(DETAIL A) a Cable 4 mm >_4 >_4 2 Solar cable;(+) 3.3 in(1100 mm),(-) 3.3 in(1100 mm) -I /�I 32mm DETAILA 116mm1 Connector Multi-Contact MC4, I P65 and I P68 24.5mmI- I8.5mm ELECTRICAL CHARACTERISTICS POWER CLASS 305 310 315 320 325 330 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5W+5W/-OW) Power at MPP2 PMpp [W] 305 310 315 320 325 330 Short Circuit Current* Isc [A] 9.93 9.98 10.04 10.09 10.14 10.20 =• Open Circuit Voltage* Voc [V] 39.35 39.61 39.87 40.13 40.40 40.66 E ▪ Current at MPP* IMPP [A] 9.44 9.50 9.55 9.60 9.66 9.71 Voltage at MPP* VMpp [V] 32.30 32.64 32.98 33.32 33.65 33.98 Efficiency2 n [%] >_18.1 >_18.4 >_18.7 >_19.0 >_19.3 >_19.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NOC3 Power at MPP2 PMpp [W] 226.0 229.7 233.4 237.2 240.9 244.6 E Short Circuit Current* Isc [A] 8.00 8.05 8.09 8.14 8.18 8.22 1 Open Circuit Voltage* Voc [V] 36.80 37.05 37.30 37.54 37.79 38.04 ▪ Current at MPP* IMpp [A] 7.43 7.47 7.51 7.56 7.60 7.64 Voltage at MPP* VMpp [V] 30.43 30.75 31.07 31.39 31.70 32.01 11000W/m2,25°C,spectrum AM 1.5G 2 Measurement tolerances STC±3%;NOC±5% 3800W/m2,NOCT,spectrum AM 1.5G *typical values,actual values may differ Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE 0 100 „o QCELLS At least 98%of nominal power during first year. 98 Indust standard for linear warranties' E_Ei Industry Standard for tiered warranties Thereafter max.0.54%degradation per year. 95 At least 93.1%of nominal power up to 10 years. W 100 L ------- I > At least 85%of nominal power up to 25 years. E I I QZ 90 ul Z All data within measurement tolerances. � 90 r i i -1 - C Full warranties in accordance with the warranty 2-1 I W 85 terms of the Q CELLS sales organization of your I I I I c 80 respective country. 80 200 400 600 800 1000 IRRADIANCE[W/mel Q 75 z 0 5 10 15 20 25 ,--i1 Typical module performance under low irradiance conditions in o Standard terms of guarantee for the 10 PV companies YEARS with the highest production capacity in 2014(as at:September 2014) comparison to STC conditions(25°C,1000 W/m2). 1 fY I O TEMPERATURE COEFFICIENTS 0 Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Voc 13 [%/K] -0.28 OI m Temperature Coefficient of PMpp y [%/K] -0.37 Normal Operating Cell Temperature NOCT [°F] 113±5.4(45±3°C) 2I PROPERTIES FOR SYSTEM DESIGN `�0 Maximum System Voltage Vsys [V] 1000(IEC)/1000(UL) Safety Class II Q Maximum Series Fuse Rating [A DC] 20 Fire Rating C(IEC)/TYPE 1 (UL) c3 Design load,push(UL)2 [lbs/ft2] 75(3600 Pa) Permitted module temperature -40°F up to+185°F on continuous duty (-40°C up to+85°C) Design load,pull(UL)2 [lbs/ft2] 55.6(2666 Pa) 2 see installation manual i 2 QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION UL 1703;VDE Quality Tested;CE-compliant; Number of Modules per Pallet 32 IEC 61215(Ed.2);IEC 61730(Ed.1)application class A 7. Number of Pallets per 53'Trailer 30 f N V C Ea Number of Pallets per 40'High Cube Container 26 D E Pallet Dimensions(L x W x H) 69.3 in x 45.3 in x 46.9 in C UL 11703 US (1760mm x 1150mm x 1190mm) (254141) c' Pallet Weight 1415 lbs(642 kg) U NOTE:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. A Hanwha Q CELLS America Inc. 300 Spectrum Center Drive,Suite 1250,Irvine,CA 92618,USA I TEL+1 949 748 59 96 I EMAIL inquiry@us.q-cells.com I WEB www.q-cells.us SOIâPIø [fW oc W SolarEdge Single Phase Inverters pC For North America I I I SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US e r tee x12_25 warranty lei 80' to ik; The best choice for SolarEdge enabled systems • Integrated arc fault protection for NEC 2011 690.11 compliance • Rapid shutdown for NEC 2014 690.12 - Superior efficiency(98%) - Small,lightweight and easy to install on provided bracket - Built-in module-level monitoring - Internet connection through Ethernet or Wireless - Outdoor and indoor installation — Fixed voltage inverter, DC/AC conversion only - Pre-assembled Safety Switch for faster installation — Optional—revenue grade data,ANSI C12.1 USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL www.solaredge.us IA 'PI!_[!LSingle Phase Inverters for North America SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ SE7600A-US/SE10000A-US/SE11400A-US SE3000A-US SE3800A-US SE5000A-US SE6000A-US SE7600A-US SE10000A-US SE11400A-US OUTPUT - 9980 @ 208V Nominal AC Power Output 3000 3800 5000 6000 7600 11400 VA 10000 V 240V Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA 5450 V 240V 10950 V 240V AC Output Voltage Min.-Nom.-Max.111 183-208-229 Vac AC Output Voltage Min.-Nom.-Max.o ✓ ✓ ✓ ✓ ✓ ✓ ✓ 211-240-264 Vac AC Frequency Min.-Nom.-Max.11} 59.3-60-60.5 Hz Max.Continuous Output Current 12.5 1 16 1 2124 @ @ 240V208V 25 1 48 32 42 @ 240V208V 1I 47.5 A GFDI Threshold I 1 A Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes Yes INPUT Maximum DC Power(STC) 4050 1 5100 1 6750 1 8100 1 10250 1 13500 1 15350 W Transformer-less,Ungrounded Yes ............................................................ Max.Input Voltage 500 Vdc Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc Max.Input Current(2) 9.5 13 16.5 @ 208V 15.5 V 240V 18 23 33 @ 208V 30.5 V 240V 1 34.5 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600LSensitivity Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 98 97 @ 208V 97 @ 208V CEC Weighted Efficiency 97.5 98 97.5 97.5 97.5 98 q 240V 97.5 V 240V Nighttime Power Consumption 1 <2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces R5485,R5232,Ethernet,ZigBee(optional) Revenue Grade Data,ANSI C12.1 Optional131 ............................................................ Rapid Shutdown-NEC 2014 690.12 Yes STANDARD COMPLIANCE Safety I UL1741,U L1699 B,U L1998,CSA 22.2 Grid Connection Standards IEEE1547 Emissions FCC partl5 class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4"minimum/16-6 AWG 3/4"minimum/8-3 AWG DC input conduit size/41 of strings/ 3/4"minimum/1-3 strings/ 3/4"minimum/1-2 strings/16-6 AWG AWG range.. .. ......................... ........ ...14*6 AWG... ....... ......... .. ..... ... ... Dimensions with Safety Switch 30.5 x 12.5 x 7.2/775 x 315 x 184 30.5 x 12.5 x 10.5/ in/ (HxWxD) 775 x 315 x 260 mm Weight with Safety Switch 51.2/23.2 I 54.7/24.7 88.4/40.1 lb/kg Natural convection Cooling Natural Convection and internal Fans(user replaceable) fan(user replaceable) Noise <25 <50 dBA Min.-Max.Operating Temperature -13 to+140/-25 to+60(-40 to+60 version availablee4)) °F/°C Range Protection Rating NEMA 3R (1)For other regional settings please contact SolarEdge support. (2)A higher current source may be used;the inverter will limit its input current to the values stated. (3)Revenue grade inverter P/N:SExxxxA-U5000NNR2(for 7600W inverter:5E7600A-U5002NNR2). (4)-40 version P/N:SExxxxA-US000NNU4(for 7600W inverter:SE7600A-U5002NNU4). (lb �k�� p HS �,Sr, O ©SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:01/2016.V.02.Subject to change without notice. SOIâPIø [fW Lil SolarEdgePowerOptimizer Module For N America A P300 / P320 / P370 / P400 / P405 III 111111Sio, -3, / g 251escs arOci %ay 49 JazniN f • PV power optimization at the module-level — Up to 25% more energy — Superior efficiency(99.5%) — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTH AFRICA-BULGARIA-INDIA www.solaredge.us SolarEdge Power Optimizer SOla r • • Module Add-On for North America P300/ P320/ P370/ P400/ P405 P300 P320 P370 P400 P405 (for 60-cell mod- (for high-power (for higher-power (for 72&96-cell (for thin film ules) 60-cell modules) 60 and 72-cell modules) modules) modules) INPUT Rated Input DC Power(1) 300 320 370 400 405 W Absolute Maximum Input Voltage 48 60 80 125 Vdc (Voc at lowest temperature) MPPT Operating Range 8-48 8-60 8-80 12.5-105 Vdc Maximum Short Circuit Current(Isc) 10 11 10.1 Adc Maximum DC Input Current 12.5 13.75 12.63 Adc Maximum Efficiency 99.5 Weighted Efficiency 98.8 Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1 Vdc Optimizer STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters 128x152x35/ 128x152x50/ Dimensions(WxLxH) 128 x 152 x 27.5/5 x 5.97 x 1.08 5x5.97x1.37 5x5.97x1.96 mm/in Weight(including cables) 630/1.4 750/1.7 845/1.9 gr/lb Input Connector MC4 Compatible MC4/ MC4 Compatible Amphenol AH4 Double Insulated; Output Wire Type/Connector Double Insulated;MC4 Compatible MC4/ Double Insulated;MC4 Compatible Amphenol AH4 Output Wire Length 0.95/3.0 1.2/3.9 m/ft Operating Temperature Range -40-+85/-40-+185 °C/°F Protection Rating IP68/NEMA6P Relative Humidity I 0-100 I (1)Rated STC power of the module.Module of up to+5%power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER(2" HD-WAVE Minimum String Length 8 10 18 (Power Optimizers) Maximum String Length 25 25 50 (Power Optimizers) Maximum Power per String 5700(6000 with 5250 6000 12750 W SE7600H-US) Parallel Strings of Different Lengths or Orientations Yes (2)For detailed string sizing information refer to:http://www.solaredge.com/sites/default/files/string_sizing_na.pdf. (3)It is not allowed to mix P405 with P300/P370/P400/P600/P700 in one string. CE (11) /STEL ©SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:03/2017 V.02.Subject to change without notice. J'#/AIL. IRONRIDGE FlashFootTM Rapid & Secure Solar Attachments IronRidge FlashFootTM is an all-in-one solar mounting product for composition shingle roofs that eliminates the need for separate standoffs, flashings, and L-feet. FlashFoot incorporates a number of structural and waterproofing features to securely attach IronRidge Rails to roof structures, while also protecting against JA water intrusion and weather damage. 111 Dual Mechanical Seal At the core of the FlashFoot,a pre-installed rubber bushing forms a dual mechanical , esa thesealcavitywith of its theexterior L-foot andcompritssinterioredgainst tightly ..- wrapping around the shaft of the lag bolt. O VP -444 rl; Oso,, The k Ness ♦ to. -� 4.1* Load Distribution Plate A solid metal plate below the L-foot increases the FlashFoot's structural strength and prevents any deformation of the flashing during installation. Water Shedding Design A wide flashing layer combined with an Certified compliant elevated sealing platform maximizes the A P Mo with IBC and IRC. FlashFoot's water shedding ability. ES Tech Brief Installation Overview Tools Required: tape measure, chalk line, stud finder, roofing bar, caulking gun with an approved sealant, drill with 1/4" bit and 1/2" socket. 2 - 3rd course I � I � I I , I Rafter � I 2nd course I � Zsel 1st course Locate rafters and snap vertical and horizontal lines Slide flashing, between 1st and 2nd course, so the to mark locations of flashings. Drill 1/4" pilot holes, top is at least 3/4" above the edge of the 3rd course then backfill with an approved sealant. and the bottom is above the edge of the 1st course. 1UPPI N Line up pilot hole with flashing hole and insert lag The FlashFoot is now installed and ready for bolt through bonded washer, L-Foot, and flashing. IronRidge Rails. With provided L-foot fasteners pre- Tighten lag bolt until fully seated. loaded into rails, drop rails into open L-foot slots. Testing & Certification FlashFoot is certified for compliance with the International Building Codes (IBC) & International Residential Codes (IRC) by IAPMO-ES. Mechanical testing conformed to the standard for Testing and Analysis of Joist Hangers and Miscellaneous Connectors (ECOO2-2011), and rain testing conformed to the Underwriters Laboratory Standard for Gas Vents (UL 441-96 Section 25). Lag pull-out(withdrawal)capacities(lbs)in typical roof lumber(ASD) Specific Gravity 5/16"Shaft,3"Thread Depth Douglas Fir,Larch .50 798 Douglas Fir,South .46 705 Engelmann Spruce,Lodgepole Pine(MSR 1650 f&higher) .46 705 Hem,Fir .43 636 Hem,Fir(North) .46 705 Southern Pine .55 921 Spruce,Pine,Fir .42 615 Spruce,Pine,Fir(E of 2 million psi and higher grades of MSR and MEL) .50 798 Sources:American Wood Council,NDS 2005,Table 11.2A,11.3.2A,Notes:i)Thread must be embedded in a rafter or other structural roof member.in See IBC for required edge distances. ©2014 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.01 ZIAk Tech Brief ZAlihk IRON RIDGE XR Rail F Solar Is Not Always Sunny . --,,__. ,,. ... - „I, ---- , , - „, _ ,,,,, ,,, .. _ Over their lifetime, solar panels experience countless ` • extreme weather events. Not just the worst storms in years, ��_�--�.... � f but the worst storms in 40 years. High winds capable of . ' :-../ ,f: --7,,,,_ „,,, ; t ---- . ripping panels from a roof, and snowfalls weighing / - --,-_-,:„.7 _,X.--... '''' / 1 '''-,7--- -/ -Z '4 -.- enough to buckle a panel frame. --_-��_ -•- I y: , -,,,,_ ---,1`:-,__ __ . ",,,,,,.. it 4 .. ..„. . .. XR Rails are the structural backbone preventing ._ -__ [ ;-- .., .. 4~ . these results. They resist uplift, protect • =.- against buckling and safely and efficiently -- • - �- transfer loads into the building structure. 4 ~ s ' ....-_-.7_,_4- Their superior spanning capability �a4� � _, - -- _ requires fewer roof attachments, reducing the number of roof - ~:- ��` penetrations and the amount �� of installation time. . -.„_,.._ • -.,,, .____. _ 7...... w, , i pit,„z. 1.. li / r- 0 . ,...'. • - - Wim: '4 'N'441111114 k Force-Stabilizing Curve Sloped roofs generate both vertical and lateral i. forces on mounting rails which can cause them . rto bend and twist.The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting.This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat& Pitched Roofs Corrosion-Resistant Materials XR Rails are IronRidge offers All XR Rails are made of marine-grade compatible with a range of tilt leg aluminum alloy,then protected with an r) FlashFoot and options for flat anodized finish.Anodizing prevents surface other pitched roof roof mounting and structural corrosion,while also providing 1111110 attachments. applications. a more attractive appearance. Tech Brief XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. on XR10 XR100 XR1000 XR10 is a sleek, low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among rail, perfectly matched to regions mounting rail. It supports a range of solar mounting rails. It's built to handle without snow. It achieves 6 foot spans, wind and snow conditions,while also extreme climates and spans 12 feet or while also staying light and economical. maximizing spans. more for commercial applications. • 6'spanning capability • 8'spanning capability • 12'spanning capability • Moderate load capability • Heavy load capability • Extreme load capability • Clear anodized finish • Clear&black anodized finish • Clear anodized finish • Internal splices available • Internal splices available • Internal splices available Rail Selection The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria:ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. Load Rail Span Snow(PSF) Wind (MPH) 4' 5'4" 6' 8' 100 120 None 140 XR10 XR100 XR1000 160 100 120 10-20 • 140 160 100 30 160 100 40 • 160 r — 50-70 160 80-90 160 ©2014 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.10 ZiAk Tech Brief 'AIL IRON RIDGE UFO Family ofComponents Simplified Grounding for Every Application The UFO family of components eliminates the need for F7, separate grounding hardware by bonding solar modules directly to IronRidge XR Rails. All system types that feature the UFO family—Flush Mount, Tilt Mount and Ground Mount—are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. ,, la --"N, Stopper Sleeve Ar Universal Fastening Object(UFO) The Stopper Sleeve snaps The UFO securely bonds solar modules to XR onto the UFO,converting it into Rails. It comes assembled and lubricated,and a bonded end clamp. can fit a wide range of module heights. k'1 / ti rt . /_?1-->„.., ' ..-. ' -- . - ' - - ' - . - --:‘, ..—,:- '' - _ , „.. ./ ..,... •---Q'...,, --,.,:. .::*---. . ----. - . - r /:_._.i.. .---__...__. •- ;,_ dr)..:::—.i.:7":---,,..s ./.--: -1.:..' --/--,.. r .' ' - - "---- - . ' , - --:-:::-----._ k �: �;-,, ...:)7/T. * ,. � ti._... tit r h `•` f ✓ � '• 'fes a r - ---- 0 -...„;/ -.._ '' ee.i .-.., . -----.)< ' ----:- / } r � i #J p fes- y -- r -+ yA�- w / '41S. _As' _ '----$:__ '.n. _tom- Bonded Splice �. _{° Each Bonded Splice uses `. ti°,i�,.: .- et- self-drilling screws to form .,#` a secure connection. No '.7,i _� ��� • bonding strap needed. • Grounding Lug A single Grounding Lug Bonded Attachments L, m connects an entire row The bonding bolt attaches of PV modules to the and bonds the L-foot to the \11 .1 , ' grounding conductor. rail. It is installed with the same socket as the rest of the system. Tech Brief System Diagram ElIV -- — - - - - 6 _ _ _ _ _ _ _ .... _ .! MM. ..—. .er. !MR MME 10 — — MI= 1 Ili II -•-• OE _ _ _ _ _ 1 1 1 1 1 Fo_ III 41011 71-1-1 7 1 10 _ _ _ _ _ _ _ 0 _ _ _ _ _ _ _411= Bill _ 41 - - II I 1 _11_1_ II . _ _ _ _ _ _ _ _ 0 - - - -40- - - AM 1 1 1 1 -AK aler- - El - - - - - - - i 11 -_ 1 _11_1_ I 1 0 i -_ i i i i i i 0 _ _ _ _ _ _ _ _0 I I II 3 0 UFO stepper Sleeve • Grounding LigBended Splice Ground Wire Q Approved Enphase microinverters can provide equipment grounding of IronRidge systems, eliminating the need for grounding lugs and field installed equipment ground conductors (EGC).A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. U L Certification Cross-System Compatibility v p v The IronRidge Flush Mount, Feature 1 Flush Mount Tilt Mount I Ground Mount Tilt Mount, and Ground Mount XR Rails v Ne XR1000 Only Systems have been listed to UL - - I 2703 by Intertek Group plc. UFO/Stopper v Ne v Bonded Splice v Ne N/A UL 2703 is the standard for - t - evaluating solar mounting Grounding Lugs 1 per Row 1 per Row 1 per Array systems. It ensures these devices Microinverters Enphase - M250-72 M250-60 M215-60 C250-72 will maintain strongelectrical and p ' & Power Darfon - MIG240, MIG300, G320, G640 mechanical connections over Optimizers SolarEdge - P300, P320, P400, P405, P600, P700, P730 an extended period of time in - - extreme outdoor environments. Fire Rating Class A Class A N/A Modules Tested or Evaluated with over 400 Framed Modules ® Go to IronRidge.com/UFO Refer to installation manuals for a detailed list. ©2016 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.0 ZIAWL