HomeMy WebLinkAbout20230113 Saratoga Joinery Duct Work Plans3
2
1
KEYNOTE TAG SYMBOL, # TAG TO REFERENCE BELOW.
SHEET KEYED NOTES:
1.PROVIDE 24x30 INTAKE LOUVER AT LOCATION OF LOWER WINDOW PANE. INFILL AREA
AROUND LOUVER PER ARCHITECTURAL REQUIREMENTS. PAINT LOUVER PER
ARCHITECTURAL FINISH REQUIREMENTS. PROVIDE WEATHER TIGHT SEAL.
2.PROVIDE 14x12 EXHAUST DUCT OUT AT LOCATION OF UPPER WINDOW PANE. ROUTE
DUCT UP TO ABOVE ROOF. INFILL AREA AROUND DUCT PER ARCHITECTURAL
REQUIREMENTS. FINISH ALL SURFACES PER ARCHITECTURAL REQUIREMENTS.
PROVIDE WEATHER TIGHT SEAL.
3.ROUTE EXHAUST DUCT TO 30" ABOVE ADJACENT ROOF COMPONENTS. PROVIDE
GOOSENECK DISCHARGE FITTING AT TOP. PROVIDE BIRD SCREEN AR POINT OF
DISCHARGE. DIRECT DISCHARGE AWAY FROM NEAREST LOT LINE.
4.RELATIVE LOCATION OF FRESH-AIR INTAKE AND EXHAUST DUCT. iNTAKE AND
EXHAUST ARE CONNECTED TO ENERGY RECOVERY VENTILATION SYSTEM. ERV
EQUIPMENT IS LOCATED IN BASEMENT.
5.APPROXIMATE INTERIOR LOCATION OF DUST COLLECTOR FAN. POINT SOURCE FOR
SOUND GENERATED INSIDE BUILING. INTERIOR WALLS SHALL BE SOUND ATTENUATED
TO BLOCK BREAKOUT SOUND FROM BUILDING. EQUIPMENT SHALL NOT COMMUNICATE
DIRECTLY WITH EXTERIOR. REFERENCE MANUFACTURER'S PUBLISHED SOUND DATA
FOR INTERIOR NOISE GENERATED.
6.PROVIDE NEW DUCTWORK SECURED TO EXISTING BUILDING AT EXISTING MORTAR
JOINTS ONLY. FASTENING SYSTEM SHALL BE EASILY REVERSIBLE TO MINIMIZE ANY
DAMAGE TO THE EXISTING BRICK UPON REMOVAL. PAINT NEW DUCTWORK "BRICK
COLOR".
7.REMOVE AND REPLACE WINDOW AND STORE FOR REUSE. CONVEY TO OWNER FOR
REINSTALL IN THE EVENT DUCTWORK IS REMOVED IN THE FUTURE.
#
DRAWING NO:
PROJECT NO:
REVISION/SUBMISSIONNo.DATE
DATE
SHEET:
DESIGNED:
CHECKED:
DRAFTED:
SCALE :
:TITLE:12/19/2022--PERMIT SUBMISSION
UNAUTHORIZED ALTERATION OR ADDITION
TO THIS DOCUMENT IS A VIOLATION OF
SECTION 7209 SUBDIVISION 2 OF THE NEW
YORK STATE EDUCATION LAW
69 CAROLINE STREETCOMMERCIAL ALTERATIONSSARATOGA JOINERY - WOOD SHOPSARATOGA SPRINGS, NEW YORK 128662237
12/19/2022
C.STEAD
C.STEAD
C.STEAD
4 OF 4
MECHANICAL
M4
February 27, 20231/2/20231UPDATED ALL SHEETS PLAN VIEW - SECOND FLOOR AREASAS NOTED
SCALE:
EAST ELEVATION
1/8" = 1'-0"M4
2
GENERAL SHEET NOTES
1.ALL WORK INDICATED ON DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY THE
SCOPE OF WORK AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND COMPONENTS.
2.REFER TO ADDITIONAL REQUIREMENTS OF SHEET M1.
ADD SHEET M4 2/20/232
SCALE:
SITE DETAILS
1/16" = 1'-0"M4
1
SEE DETAIL 3 THIS SHEET
4
ARCHITECTURAL LOUVER
EXTRUDED ALUMINUM STATIONARY LOUVER, J BLADE TYPE, PAINTABLE.
MINIMUM FREE AREA OF 2.1 SQUARE FEET.
SCALE:
DUST COLLECTOR
BASIS OF DESIGN
NTSM4
4
5
SCALE:
EAST ELEVATION
ENLARGED VIEW
3/8" = 1'-0"M4
3
6
6
7
7
7
SCALE:
VIEW FROM ALLY
NTSM4
5
SCALE:
CAROLINE STREET
VIEW FROM
NTSM4
6
4
SHEET M4 - FULL SHEET REVISION 2/27/233
COLLECTOR WILL BE LOCATED INSIDE BUILDING.
SEE INTERIOR EQUIPMENT PLANS.