Loading...
HomeMy WebLinkAbout20230067 31 Woodlawn Exterior Modifications PlansTV SEATING FILING/STORAGE PRIVACY FILM APPLIED TO LENGTH OF GLASS PRIVACY FILM APPLIED TO LENGTH OF GLASS REF. VESTIBULE 101 ELEVATOR 119 STAIR 1 118 PRINT HUB 111 LARGE CONFERENCE ROOM 110 WOMEN'S RESTROOM 113 MEN'S RESTROOM 114 STAIR 2 112 VESTIBULE 107 KITCHENETTE 108 FUTURE GROWTH 109 RECEPTION 102 PERSONAL LINE MANAGER OFFICE 103 PRIVATE OFFICE/SMALL CONFERENCE ROOM 117 PRIVATE OFFICE 106 CORRIDOR 105 PERSONAL LINES 104 CORRIDOR 116 PERSONAL LINES / ADMINISTRATION 115 NEW RAMP 1 2 40 8 24 x 36: 12 x 18: 1/4" = 1' 1/8" = 1' SHEET #: N 2/8/2023 AMSURE DESIGN REVIEW BOARD SUBMISSION MAIN LEVEL FLOOR PLAN 01 TV NEW WINDOW NEW WINDOW CREDENZACREDENZAMINI FRIDGE NEW WINDOW FEATURE WALL ELEVATOR 218 STAIR 1 217 (PAUL) PRIVATE OFFICE 203 CONFERENCE ROOM 210 WOMENS RESTROOM 213 MEN'S RESTROOM 214 STAIR 2 212 MATT D'BATE OFFICE 206 COMMERCIAL LINES 209 OFFICE SUPPLY/PRINTING HUB 202 COMMERCIAL LINES 215 COMMERCIAL LINES 207 PRINTING & KITCHENETTE 208 CORRIDOR 211 COMMERCIAL LINES & EMPLOYEE BENEFITS 204 CORRIDOR 205 CORRIDOR 201 CORRIDOR 216 1 2 40 8 24 x 36: 12 x 18: 1/4" = 1' 1/8" = 1' SHEET #: N 2/8/2023 AMSURE DESIGN REVIEW BOARD SUBMISSION UPPER LEVEL FLOOR PLAN 02 REF. TALL CAB. PRIVACY FILM ON GLASS SHOWER SHOWER LOCKERS LOCKERS TV VEND. VEND. PRIVACY FILM ON GLASS FLEX SPACE 010 IT/DATA/MECHANICAL 002 TRAINING/CLASS ROOM 003 BREAK ROOM 004 STORAGE 005 STORAGE 006 IT/DATA/MECHANICAL 007 STORAGE 008 STAIR 2 009 MEN'S LOCKER ROOM 011 WOMEN'S LOCKER ROOM 012 STAIR 1 013 ELEVATOR 014 CORRIDOR 001 1 2 40 8 24 x 36: 12 x 18: 1/4" = 1' 1/8" = 1' SHEET #: N 2/8/2023 AMSURE DESIGN REVIEW BOARD SUBMISSION BASEMENT FLOOR PLAN 03 DRINKING FOUNTAIN STEEL COLUMN, TYPICAL EXISTING HVAC UNIT, TYPICAL EXISTING HOOK MOUNTED FIRE EXT LOCATION EXISTING ALARM SYSTEM PANEL 1 2 40 8 24 x 36: 12 x 18: 1/4" = 1' 1/8" = 1' SHEET #: N 2/8/2023 AMSURE DESIGN REVIEW BOARD SUBMISSION MAIN LEVEL DEMOLITION PLAN 04 EXISTING HVAC UNIT, TYPICAL EXISTING PLYWOOD PANEL AND IT EQUIPMENT EXISTING RECESSED ELECTRICAL PANEL STEEL COLUMN, TYPICAL EXISTING IT EQUIPMENT EXISTING LADDER TO ROOF EXISTING HOOK MOUNTED FIRE EXT LOCATION 1 2 40 8 24 x 36: 12 x 18: 1/4" = 1' 1/8" = 1' SHEET #: N 2/8/2023 AMSURE DESIGN REVIEW BOARD SUBMISSION UPPER LEVEL DEMOLITION PLAN 05 STAIR 1 013 ELEVATOR 014 EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT EXISTING ELEVATOR EQUIPMENT EXISTING EMERGENCY GENERATOR PANELS EXISTING IT EQUIPMENT EXISTING ELECTRICAL EQUIPMENT EXISTING HVAC UNIT, TYPICAL EXISTING HOOK MOUNTED FIRE EXT LOCATION EXISTING HOOK MOUNTED FIRE EXT LOCATION 1 2 40 8 24 x 36: 12 x 18: 1/4" = 1' 1/8" = 1' SHEET #: N 2/8/2023 AMSURE DESIGN REVIEW BOARD SUBMISSION BASEMENT DEMOLITION PLAN 06 NEW EXTERIOR LIGHTS: WAC LIGHTING "ENDURANCE FLOOD" WALLPACK (6" X 5"), BLACK; COLOR TEMP. 3000K; 2450 LUMENS NEW WINDOWS, TYPICAL: ANDERSEN 100 SERIES, WOOD COMPOSITE WINDOWS, BLACK 1 2 40 8 24 x 36: 12 x 18: 1/4" = 1' 1/8" = 1' SHEET #: 2/8/2023 AMSURE DESIGN REVIEW BOARD SUBMISSION NORTH ELEVATION 07 NEW EXTERIOR LIGHTS: WAC LIGHTING "ENDURANCE FLOOD" WALLPACK (6" X 5"), BLACK; COLOR TEMP. 3000K; 2450 LUMENS NEW EXTERIOR SCONCE: WAC LIGHTING "MOD" OUTDOOR WALL SCONCE (6" X 5"), BLACK; COLOR TEMP 3000K; 1165 LUMENS 1 2 40 8 24 x 36: 12 x 18: 1/4" = 1' 1/8" = 1' SHEET #: 2/8/2023 AMSURE DESIGN REVIEW BOARD SUBMISSION SOUTH ELEVATION 08 NEW EXTERIOR SCONCES: WAC LIGHTING "MOD" OUTDOOR WALL SCONCE (6" X 5"), BLACK; COLOR TEMP 3000K; 1165 LUMENS NEW EXTERIOR SCONCES: WAC LIGHTING "MOD" OUTDOOR WALL SCONCE (6" X 5"), BLACK; COLOR TEMP 3000K; 1165 LUMENS 1 2 40 8 24 x 36: 12 x 18: 1/4" = 1' 1/8" = 1' SHEET #: 2/8/2023 AMSURE DESIGN REVIEW BOARD SUBMISSION EAST & WEST ELEVATIONS 09 SCALE:1/4" = 1'-0" PROPOSED WEST ELEVATION SCALE:1/4" = 1'-0" PROPOSED EAST ELEVATION NEW CONSTRUCTION KEY NOTES (EXTERIOR): 1 2 3 4 5 CLEAN MASONRY SURFACES WITH HISTORICALLY APPROPRIATE MASONRY CLEANER EXISTING EXTERIOR LIGHTS TO BE REMOVED AND REPLACED, REFER TO LIGHT FIXTURE SCHEDULE (TBD) FOR NEW SELECTION 6 REMOVE EXTERIOR SERVICE AND CONDUIT FOR INTERNAL REINSTALL REPOINT ALL MASONRY AS NEEDED NEW MASONRY OPENINGS PER DEMO PLANS REMOVE WINDOW (TYPICAL), REFER TO WINDOW SCHEDULE (TBD) FOR NEW SELECTION 7 8 MASON TO PATCH AND REPAIR CRACKING 9 REMOVE EXISTING ROOFING AND REPLACE WITH COPPER ROOFING 10 11 REMOVE METAL WINDOW GUARD (TYPICAL) 12 REMOVE EXISTING BRACKETS ATTACHED TO BRICK MASONRY INVESTIGATE EXTERIOR PIPE, CONFIRM IF NEEDED, REMOVE IF NOT NEEDED REPLACE SCREEN AROUND GENERATOR, REFER TO LANDSCAPE DRAWINGS (TBD) 13 REMOVE METAL FLAG POLE AND ATTACHMENTS 14 REPAINT ROOF STRUCTURE ABOVE ENTRY 15 REMOVE AND REPLACE RAIL (TBD) 2 1 1 1 1 1 10 1 1 7 9 6 1 12 1 5 5 6 1 5 4 4 4 11 1 9 2 11 1 7 6 10 10 4 64 2 2 3 2 5 6 4 4 5 4 4 5 8 9 SHEET #: 2/8/2023 AMSURE DESIGN REVIEW BOARD SUBMISSION NORTH DEMOLITION ELEVATION 10 1 1 2 1 3 7 7 5 3 1 8 7 7 6 5 5 12 14 4 5 4 4 44 2 2 1 1 3 8 14 4 6 2 2 1 1 1 1 5 3 3 5 6 7 8 12 4 5 14 15 5 3 2 2 3 8 5 7 6 4 4 5 NEW CONSTRUCTION KEY NOTES (EXTERIOR): 1 2 3 4 5 CLEAN MASONRY SURFACES WITH HISTORICALLY APPROPRIATE MASONRY CLEANER EXISTING EXTERIOR LIGHTS TO BE REMOVED AND REPLACED, REFER TO LIGHT FIXTURE SCHEDULE (TBD) FOR NEW SELECTION 6 REMOVE EXTERIOR SERVICE AND CONDUIT FOR INTERNAL REINSTALL REPOINT ALL MASONRY AS NEEDED NEW MASONRY OPENINGS PER DEMO PLANS REMOVE WINDOW (TYPICAL), REFER TO WINDOW SCHEDULE (TBD) FOR NEW SELECTION 7 8 MASON TO PATCH AND REPAIR CRACKING 9 REMOVE EXISTING ROOFING AND REPLACE WITH COPPER ROOFING 10 11 REMOVE METAL WINDOW GUARD (TYPICAL) 12 REMOVE EXISTING BRACKETS ATTACHED TO BRICK MASONRY INVESTIGATE EXTERIOR PIPE, CONFIRM IF NEEDED, REMOVE IF NOT NEEDED REPLACE SCREEN AROUND GENERATOR, REFER TO LANDSCAPE DRAWINGS (TBD) 13 REMOVE METAL FLAG POLE AND ATTACHMENTS 14 REPAINT ROOF STRUCTURE ABOVE ENTRY 15 REMOVE AND REPLACE RAIL (TBD) SHEET #: 2/8/2023 AMSURE DESIGN REVIEW BOARD SUBMISSION WEST DEMOLITION ELEVATION 11 7 2 6 6 6 6 6 1 6 5 11 2 1 12 1 15 4 4 4 4 412 2 1 1 1 1 6 6 6 6 1 7 7 2 2 6 6 6 1 4 4 4 NEW CONSTRUCTION KEY NOTES (EXTERIOR): 1 2 3 4 5 CLEAN MASONRY SURFACES WITH HISTORICALLY APPROPRIATE MASONRY CLEANER EXISTING EXTERIOR LIGHTS TO BE REMOVED AND REPLACED, REFER TO LIGHT FIXTURE SCHEDULE (TBD) FOR NEW SELECTION 6 REMOVE EXTERIOR SERVICE AND CONDUIT FOR INTERNAL REINSTALL REPOINT ALL MASONRY AS NEEDED NEW MASONRY OPENINGS PER DEMO PLANS REMOVE WINDOW (TYPICAL), REFER TO WINDOW SCHEDULE (TBD) FOR NEW SELECTION 7 8 MASON TO PATCH AND REPAIR CRACKING 9 REMOVE EXISTING ROOFING AND REPLACE WITH COPPER ROOFING 10 11 REMOVE METAL WINDOW GUARD (TYPICAL) 12 REMOVE EXISTING BRACKETS ATTACHED TO BRICK MASONRY INVESTIGATE EXTERIOR PIPE, CONFIRM IF NEEDED, REMOVE IF NOT NEEDED REPLACE SCREEN AROUND GENERATOR, REFER TO LANDSCAPE DRAWINGS (TBD) 13 REMOVE METAL FLAG POLE AND ATTACHMENTS 14 REPAINT ROOF STRUCTURE ABOVE ENTRY 15 REMOVE AND REPLACE RAIL (TBD) 1 1 1 2 5 6 6 6 7 11 6 4 4 4 4 4 15 SHEET #: 2/8/2023 AMSURE DESIGN REVIEW BOARD SUBMISSION SOUTH DEMOLITION ELEVATION 12 NEW CONSTRUCTION KEY NOTES (EXTERIOR): 1 2 3 4 5 CLEAN MASONRY SURFACES WITH HISTORICALLY APPROPRIATE MASONRY CLEANER EXISTING EXTERIOR LIGHTS TO BE REMOVED AND REPLACED, REFER TO LIGHT FIXTURE SCHEDULE (TBD) FOR NEW SELECTION 6 REMOVE EXTERIOR SERVICE AND CONDUIT FOR INTERNAL REINSTALL REPOINT ALL MASONRY AS NEEDED NEW MASONRY OPENINGS PER DEMO PLANS REMOVE WINDOW (TYPICAL), REFER TO WINDOW SCHEDULE (TBD) FOR NEW SELECTION 7 8 MASON TO PATCH AND REPAIR CRACKING 9 REMOVE EXISTING ROOFING AND REPLACE WITH COPPER ROOFING 10 11 REMOVE METAL WINDOW GUARD (TYPICAL) 12 REMOVE EXISTING BRACKETS ATTACHED TO BRICK MASONRY INVESTIGATE EXTERIOR PIPE, CONFIRM IF NEEDED, REMOVE IF NOT NEEDED REPLACE SCREEN AROUND GENERATOR, REFER TO LANDSCAPE DRAWINGS (TBD) 13 REMOVE METAL FLAG POLE AND ATTACHMENTS 14 REPAINT ROOF STRUCTURE ABOVE ENTRY 15 REMOVE AND REPLACE RAIL (TBD) 6 4 2 15 13 8 14 5 4 5 4 6 4 2 1 1 665 4 5 4 44 15 15 13 14 8 5 5 8 13 2 6 4 4 14 15 8 2 14 13 5 4 6 4 SHEET #: 2/8/2023 AMSURE DESIGN REVIEW BOARD SUBMISSION EAST DEMOLITION ELEVATION 13 SHEET #: 2/8/2023 AMSURE DESIGN REVIEW BOARD SUBMISSION NORTHEAST RENDERING 14 SHEET #: 2/8/2023 AMSURE DESIGN REVIEW BOARD SUBMISSION NORTHWEST RENDERING 15 SHEET #: 2/8/2023 AMSURE DESIGN REVIEW BOARD SUBMISSION WINDOWS & EXTERIOR LIGHTING 16 EXTERIOR LIGHTS: WAC LIGHTING "ENDURANCE FLOOD" WALLPACK (6" X 5"), BLACK; COLOR TEMP. 3000K; 2450 LUMENS EXTERIOR SCONCES: WAC LIGHTING "MOD" OUTDOOR WALL SCONCE (6" X 5"), BLACK; COLOR TEMP 3000K; 1165 LUMENS WINDOWS: ANDERSEN 100 SERIES, WOOD COMPOSITE WINDOWS, BLACK