Loading...
HomeMy WebLinkAbout20230026 294 Lake Solar Panels ApplicationRevised 01/2021 APPLICATION FOR: ARCHITECTURAL / HISTORIC REVIEW APPLICANT(S)* OWNER(S) (If not applicant) ATTORNEY/AGENT Name Address Phone / / / Email Identify primary contact person:  Applicant Owner Attorney/Agent * An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant’s interest in premises: Owner Lessee Under option to lease or purchase PROPERTY INFORMATION Property Address/Location: Tax Parcel #: . - - (for example: 165.52 – 4 – 37 ) Current Zoning District: Property use:  Residential Non-residential/mixed-use Type of Review:  Architectural Historic Extension/modification (of current approval) Summary description of proposed action: Has a previous application been filed with the DRC for this property? No  Yes – date(s)? _____________________ -App. No.(s)? _________________ Date Acquired by Owner: _________________ **HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED** CITY OF SARATOGA SPRINGS DESIGN REVIEW COMMISSION CITY HALL - 474 BROADWAY SARATOGA SPRINGS, NEW YORK 12866-2296 TEL: 518-587-3550 X2533 www.saratoga-springs.org [FOR OFFICE USE] _______________ (Application #) ____________ (Date received) __________________________ (Project Title) Staff Review _______________ **A “complete” application consists of 1 hard copy (original) , and 1 electronic copy of application & ALL other materials as required below: New Construction / Additions Color photographs showing site/exterior details of existing structures and adjacent properties Site plan, drawn to scale, showing existing & proposed construction, property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.); on no larger than 2’x3’ sheet – smaller preferred if legible Elevation drawings showing design of all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible Floor plans for proposed structure; on sheet no larger than 2’x3’ – smaller permitted if legible Product literature, specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) Color photographs showing site/exterior details of existing structures and that illustrate affected features Elevation drawings showing all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible Product literature, specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts only (Front setbacks: UR-1 & INST-HTR=30’; UR-4=25’; UR-2, UR-3 & NCUD-1=10’) -Installation, removal or change in material of drive- and walkways -Installation or removal of architectural, sculptural or vegetative screening over 3’ in height -Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2’ diameter) For any of above: Color photographs showing site/exterior details of existing structures, and of adjacent properties Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2’x3’ sheet – smaller preferred if legible Product literature, specifications and samples of proposed materials and colors Signage / Awnings Color photographs showing site/exterior details of existing structures, and adjacent properties Plan showing location of proposed sign/awning structure on building/premises: no larger than 11”x17” Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location Product literature, specifications and samples of proposed materials and colors Demolition Color photographs showing site/exterior details of existing structures, and of adjacent properties Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale Written description of reasons for demolition and, in addition: For structures of “architectural/historical significance”, demonstrate “good cause” why structure cannot be preserved For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a “contributing” structure in a National Register district (contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities Color photographs showing site/existing structures, and of adjacent properties Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details Consult Article 240-12.22 of the City’s Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 01/2021 Revised 01/2021 INSTRUCTIONS ARCHITECTURAL / HISTORIC REVIEW APPLICATION 1.ELIGIBILITY: An applicant to the Design Review Commission for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2.COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRC will only consider properly completed applications that contain 1 original and 1 digital version of the application and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!! 3.ACTIONS REQUIRING REVIEW: Architectural Review District Historic Review District •any exterior changes that require a building permit •any change in exterior building materials •a new, or change to an existing, sign or sign structure •demolition of a structure Within a non-residential zoning district: •a change in exterior building color •installation of an awning •Installation or exterior change to a structure requiring a building or demolition permit •any material change to exterior of a structure including: -addition or removal of exterior architectural features -installation, removal or material changes to exterior building elements such as roof, siding, windows, doors, porches, etc. -enclosure or screening or buildings openings such as windows, doors, porches, etc. -installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. Within a front yard setback: -installation, removal or material changes to drive- or walkways -installation or removal of architectural, sculptural or vegetative screening that exceeds 3’ in height -installation of accessory utility structures or radio/satellite transmission/reception devices over 2’ in diameter •a change in exterior building color within a non- residential zoning district •a new, or change to an existing, sign or awning •installation of telecommunications facilities Note – Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review. CITY OF SARATOGA SPRINGS DESIGN REVIEW COMMISSION City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x2533 www.saratoga-springs.org 4.DESIGN GUIDELINES: The Design Review Commission will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: •Height – consistent with historic form and context of site and surrounding properties •Scale – relationship of structure and its architectural elements to human size, form, perception •Proportion – relationship among building elements including front façade, windows, and doors •Rhythm – pattern resulting from repeating building elements such as door/window openings, columns, arches, and other façade elements •Directional Expression – compatibility with horizontal & vertical expression of surrounding structures •Massing & Open Space – relationship of structure to open space between it and adjoining buildings •Setback – compatibility with surrounding structures •Compatibility of the following with surrounding structures/properties: -Major building elements (storefronts, doors, windows, roof) -Building materials -Color – (in non-residential zoning districts only) 5.DECISIONS: The Design Review Commission may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of the filing date unless the project has sufficiently commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6.AGENDA DATE: Check City’s website (www.saratoga-springs.org) for meeting dates. Applications are placed on an agenda on first-come, first-served basis as determined by the completeness of the application. 7.APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance”. REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT. ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Commission responsibilities may be found in the City’s Zoning Ordinance available in City Hall and on the City’s web site at http://www.saratoga-springs.org/544/Zoning-Ordinance. Revised 01/2021 OPED Fees Type Application to Zoning Board of Appeals [1] [2]TOTAL #VARIANCE Use Variance Area Variance - Residential Area Variance - Multi-Family, Comm, Mixed-Use Interpretations Post-Work Application Fee Variance extensions Application to Design Review Commission [1]TOTAL #STRUCTURE Demolition Residential Structures Principal Accessory Extension Modification Multi-Family, Comm, Mixed-Use Structures Sketch Principal Extension Modification Multi-Family, Comm, Mixed-Use Accessory, Signs, Awnings Principal Extension Modification Post-Work Application Fee Application to Planning Board [1]TOTAL #STRUCTURE Special Use Permit [2] Special Use Permit - extension Special Use Permit - modification [2] Site Plan Review - incl. PUD: Sketch Plan Residential Residential - extension Residential - modification Non-residential Non-Residential - extension Non-Residential - modification Subdivision - incl. PUD: TOTAL #LOTS Sketch Plan Preliminary Approval [2] Residential: 1-5 lots Residential: 6-10 lots Residential: 11-20 lots Residential: 21+ lots Residential - extension Final Approval [2] Residential Non- Residential Final Approval Modification [2] Residential Non- Residential Final Approval Extension Residential Non- Residential Other:TOTAL #LOT/ACRE Post-Work Application Fee Lot L ine Adjustment Letter of Credit - m odification o r extension Letter of Credit - c ollection Recreation Fee Land Disturbance SEQRA EIS Review (Draft & Final) Legal Noticing if PB requires Public Hearing 2021 Fee $1100 + $50/app $275/var + $50/app + $125 each add'l variance $660/var + $50/app + $200 each add'l variance $550 +$50/app Add 50% App fee + $50/app 50% of App fee + $50/app $385 $55 $55 $35 $55 $165 $550 $200 $330 $140 $75 $140 Add 50% App fee $990 + $50/app $330 $450 + $50/app $330 $330 + $200/unit $200 $400 $660 + $130/1000 sf $300 $650 $330 $660 + $50/app $990 + $50/app $1320 + $50/app $1650 + 50/app $330 $1320 + $175/lot + $50/app $2000/lot + $50/app $330 + $50/app $550 + $50/app $135 $330 Add 50% App fee $350 $440 up to 1% of LoC $2000/lot or unit $660 + $55/acre TBD $50/app [1]Fees are based on per structure, except where noted. [2]Legal ad required; includes City processing and publishing __________Total Paid at Intake __________Revised Fee __________Balance Due ___/___/___Balance Paid Staff approval _______________ 2021 LAND USE BOARD FEE WORKSHEET For Administrative Use TOTAL DUE 279 Broadway Building #2 Menands, NY 12204 (518)-478-8365 (518)-953-1095 Fax I (Customer) hereby authorize Kasselman Solar LLC, to act as customer, agent & contractor, and to submit all necessary permit applications and supporting documents to the Town Building Department on my behalf. Customer Name (Print) ______________________________________________ Customer Signature__________________________________________________ Customer Address ___________________________________________________ Municipality that issues your Building Permit ______________________________ Kasselman Solar Employee Signature_____________________________________ DocuSign Envelope ID: ECE0DC98-EDB0-4987-8126-B2155BFEF4C5 294 Lake Avenue Saratoga Springs, NY 12866 Saratoga Springs Turner Bradford Turner Bradford :(676+25( '(6,*1(1*,1((563& 100 GREAT OAKS BLVD. Ϳ SUITE 117A ALBANY Ϳ NEW YORK Ϳ 12203 :HVW6KRUH'HVLJQ(QJLQHHUVۅ*UHDW2DNV%OYGۅ6XLWH$ۅ$OEDQ\1<ۅ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´RFZLWKD¶VSDQ  %DVHGRQVWUXFWXUDODQDO\VLVLWKDVEHHQGHWHUPLQHGWKDWWKH5DQG5URRIVDUHDGHTXDWH WRVXSSRUWURRIWRSVRODUSDQHOVZLWKDPD[LPXPORDGLQJRISVI  ³8QLUDF´/IRRWDQFKRUVRUHTXDOZLWK´GLDPHWHUODJVUHTXLUHGDW´RQFHQWHU PD[LPXPVWDJJHUHGZLWK´PLQLPXPHPEHGRU6&ODPSVRUHTXDOIRUPHWDOURRIV 5RRI7HFK³570LQL´RUHTXDODWWDFKPHQWVIRUGHFNDWWDFKPHQWV  3OHDVHGRQ¶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ated AC Output Current = 43.5a Nominal Operating AC Voltage = 240v EXP:07/24 Turner Bradford 294 Lake Ave Saratoga Springs , NY 12866 617-953-3848 12 LG 435 12 IQ7A-72-2-US (240V) 4.86 05779080 45676-14120 National Grid 1.6.23 SOLAR PANELS, TYP DETACHED GARAGE (N) UNIRAC RAIL (N) E - MOUNT .04" THICK 9"x12" ALUMINUM FLASHING SOLARMOUNT END MOUNT OR MID MOUNT AS REQ'D PER MFGR. (N) SOLAR PANEL (E) ROOF SURFACE(N) SOLARMOUNT L - FOOT PER MFGR. w/ 3/8"Ø BOLT & 5/8"Ø LAG SCREW w/ 3" EMBED MIN. (N) E - MOUNT CAST ALUMINUM MOUNTING BLOCK PER MFGR. NORTHPLAN NORTHTRUE SOLAR ARRAY PLAN 1 1/8" = 1'-0" TYPICAL ATTACHMENT DETAIL 2 1"=1'-0" BRADFORD RESIDENCE 294 LAKE AVE. SARATOGA SPRINGS, NY 12 SOLAR MODULES (65"X40" EA.) AND 12 IQ8 PER MANUFACTURER SPECIFICATIONS. - UNIRAC SOLAR MOUNT RAIL SYSTEM RAILS ARE CENTERED UNDER PANEL SEAMS. - RAFTER SPACING = 24"O.C. - RAIL TO ROOF MOUNT: QUICKMOUNT PV E-MOUNT LAG w/ 5/8"Ø LAG SCREW. NOTES: 1. RAIL TO ROOF ATTACHMENTS SHALL BE 4' O.C. MAX. AND LAGGED INTO A RAFTER 2. IF THE LAG BOLT CANNOT BE INSTALLED IN A RAFTER, SOLID BLOCKING SHALL BE ADDED BETWEEN RAFTERS TO ALLOW FOR LAG INSTALLATION. 3. ALL MANUFACTURER'S INSTRUCTIONS AND SPECIFICATIONS SHALL BE FOLLOWED FOR THE PRODUCTS USED. 4. SOLAREDGE OPTIMIZER FOR EACH MODULE ROOF DIMENSIONS SHOWN AS MEASURED ON ROOF; HORIZONTAL PROJECTIONS ARE NOT SHOWN. DIMENSIONS PROVIDED BY KASSELMAN SOLAR ELECTRICAL NOTES:. 1. EACH SOLAR MODULE IS ASSIGNED A MICRO-INVERTER WITH A RAPID SHUTDOWN, WHICH ARE LOCATED UNDERNEATH THEIR RESPECTIVE MODULE. LEGEND SOLAR MODULE APPLICABLE BUILDING CODES: - 2020 NYS BUILDING CODE - ASCE 7-16 DESIGN CRITERIA PER ASCE 7-16: SEISMIC DESIGN CATEGORY: B WIND SPEED: 115 M.P.H. GROUND SNOW LOAD: 50PSF S100 *PV DESIGN ADHERES TO SECTION R234-SOLAR ENERGY SYSTEMS OF THE 2020 NYS BUILDING CODE UNAUTHORIZED NOTE: IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL, TO ALTER THIS DRAWING IN ANY WAY. IF THIS DRAWING BEARING THE SEAL OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO THEIR ITEM THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. PROJ. NUMBER: P R O J E C T T I T L E S H E E T DRAWN BY: CHECKED BY: DATE: ENGINEER ALL RIGHTS RESERVED. NO PART OF THESE DRAWINGS OR SPECIFICATIONS MAY BE COPIED, REPRODUCED OR USED IN CONNECTION WITH ANY WORK, OTHER THEN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED, WITHOUT PRIOR WRITTEN AUTHORIZATION FROM THE ENGINEER. BRADFORD RESIDENCE SOLAR PLAN & ATTACHMENT DETAIL JE NN 1.3.2022 23010020 RevDate By Notes EXP:07/24 1-3-2023 :Solar Photovoltaic Module Turner Bradford 294 Lake Ave Saratoga Springs, NY 12866 PV Design adheres to relevant sections of the 2020 Residential Code [R324] of NYS and 2020 Fire Code of NYS [1204] for Solar PV systems. Electrical labels to be placed on PV equipment per NEC 690.56. Labels are site specific. Project and Installation Details January 3rd, 2023 Design Prepared by: Scott Stevens Director of PV Design & Engineering Roof Description Kasselman Solar, LLC - 279 Broadway, Bldg. 2 -Menands, NY 12204 - (518) 478-8365 SITE DESIGN 3D 294 Lake Ave Saratoga Springs, NY 12866 Contains confidential, proprietary, and/or privileged information LG435QAC-A6 About LG Electronics USA, Inc. LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels and energy storage systems. The company first embarked on a solar energy source research program in 1985, supported by LG Group’s vast experience in the semi-conductor, LCD, chemistry and materials industries. In 2010, LG Solar successfully released its first MonoX® series to the market, which is now available in 32 countries. The NeON® (previous MonoX® NeON), NeON®2, NeON®2 BiFacial won the “Intersolar AWARD” in 2013, 2015 and 2016, which demonstrates LG’s leadership and innovation in the solar industry. 435W LG NeON® R is powerful solar module that provides world-class performance. A new cell structure that eliminates electrodes on the front maximizes the utilization of light and enhances reliability. LG NeON® R is a result of LG’s efforts to increase customer’s values beyond efficiency. LG NeON® R features enhanced durability, performance under real-world conditions, an enhanced warranty and aesthetic design suitable for roofs. 66 Roof Aesthetics LG NeON® R has been designed with aesthetics in mind: the lack of any electrodes on the front creates an improved, modern aesthetic. Enhanced Performance Warranty The LG NeON® R has an enhanced performance warranty. After 25 years, LG NeON® R is guaranteed at least 92.5% of initial performance. 25-Year Limited Product Warranty The NeON® R is covered by a 25-year limited product warranty. In addition, up to $450 of labor costs will be covered in the rare case that a module needs to be repaired or replaced. More generation per square meter The LG NeON® R has been designed to significantly enhance its output, making it efficient even in limited space. Features yrs25 Warranty When you go solar, ask for the brand you can trust: LG Solar General Data Cell Properties (Material/Type)Monocrystalline / N-type Cell Maker LG Cell Configuration 66 Cells (6 x 11) Module Dimensions (L x W x H)1,910mm x 1,042mm x 40mm Weight 20.5 kg Glass (Material)Tempered Glass with AR Coating Backsheet (Color)White Frame (Material)Anodized Aluminium Junction Box (Protection Degree)IP 68 with 3 Bypass Diodes Cables (Length)1,250mm x 2EA Connector (Type/Maker)MC 4 / MC Electrical Properties (NMOT) Model LG435QAC-A6 Maximum Power (Pmax)[W]330 MPP Voltage (Vmpp)[V]38.8 MPP Current (Impp)[A]8.49 Open Circuit Voltage (Voc)[V]45.8 Short Circuit Current (Isc)[A]9.02 Temperature Characteristics NMOT*[°C] 44 ± 3 Pmax [%/°C]-0.29 Voc [%/°C]-0.24 Isc [%/°C] 0.04 *NMOT (Nominal Module Operating Temperature): Irradiance 800 W/m2, Ambient temperature 20°C, Wind speed 1 m/s, Spectrum AM 1.5 Operating Conditions Operating Temperature*[°C] -40 ~+85 Maximum System Voltage [V]1,000 Maximum Series Fuse Rating [A]20 Mechanical Test Load** (Front)[Pa/psf]5,400 Mechanical Test Load** (Rear)[Pa/psf]4,000 *The operating ambient temperature of these devices may exceed 40°C at full load for all wire sizes if is determined suitable in the field use application. **Based on IEC 61215-2 : 2016 (Test Load = Design Load x Safety Factor (1.5)) *STC (Standard Test Condition): Irradiance 1000 W/m2, Cell temperature 25°C, AM 1.5 Measure Tolerance: 3%+- Electrical Properties (STC*) Model LG435QAC-A6 Maximum Power (Pmax)[W]435 MPP Voltage (Vmpp)[V]41.1 MPP Current (Impp)[A]10.59 Open Circuit Voltage (Voc, 5%)[V]48.0 Short Circuit Current (Isc, 5%)[A]11.20 Module Efficiency [%]21.9 Power Tolerance [%]0 ~ +3 + + - - I-V Curves 1042.0 / 41.0 (Size of Short Side) 1002.0 / 39.4 (Distance between Holes) 175.0 / 6.9 1250.0 / 49.2 Cable Length 40.0 / 1.57 105.0 / 4.1243 / 9.616 - 8.0 x 3.0 / 0.3 x 0.1 Drain Holes 8 - Ø4.3 / 0.2 Grounding Holes 4 - 8.5 x 12.0 / 0.3 x 0.5 Mounting Holes 1424.0 / 56.1 (Distance between Mounting Holes)1910.0 / 75.2 (Size of Long Side)LG435QAC-A6 200W 400W 600W 800W 1000W Voltage [V]Current [A]12.0 10.0 8.0 6.0 4.0 2.0 0.0 0.0 10.05.0 20.015.0 30.025.0 45.040.035.0 LG Electronics USA, Inc. Solar Business Division 2000 Millbrook Drive Lincolnshire, IL 60069 www.lg-solar.com Product specifications are subject to change without notice. LG435QAC-A6.pdf 021221 © 2021 LG Electronics USA, Inc. All rights reserved. Certifications and Warranty Certifications IEC 61215-1/-1-1/2 : 2016, IEC 61730-1/2:2016, UL 61730-1 : 2017, UL 61730-2 : 2017 ISO 9001, ISO 14001, ISO 50001 OHSAS 18001 Salt Mist Corrosion Test IEC 61701:2011 Severity 6 Ammonia Corrosion Test IEC 62716 : 2013 Hail Test 25mm (1") diameter at 23m/s (52mph) Module Fire Performance Type 1 (UL 61730) Fire Rating Class C (UL 790, ULC / ORD C 1703) Solar Module Product Warranty 25 Years Solar Module Output Warranty Linear Warranty* *Improved: 1st year 98.5%, from 2-24th year: -0.25%/year down, 92.5% at year 25 Packaging Configuration Number of Modules per Pallet [EA]25 Number of Modules per 40' Container [EA]600 Number of Modules per 53' Container [EA]800 Packaging Box Dimensions (L x W x H)[mm]1,960 x 1,120 x 1,221 Packaging Box Dimensions (L x W x H)[in]77.2 x 44.1 x 48.1 Packaging Box Gross Weight [kg]549 Packaging Box Gross Weight [lb]1,210 Dimensions (mm/inch) FLASH LOC FLASH LOC-DUO Existing Array – proposed expansion project will be on the opposite side of this roof Photo of main residence from Foxhall Dr. Photo (from first install) displaying new roof with orientation to the main residence and Foxhall Dr. Birdseye view of parcel and installation site (circled in red) with orientation to neighboring properties.