HomeMy WebLinkAbout20211116 1 Veteran's Way Special Use Permit Modification Written Evaluation of Occupancy Code Compliance Verdant A R C H I T E C T U R E Written Evaluation of Occupancy Code Compliance for an Existing Dormitory Project: 1 Veteran's Way Occupancy Code Evaluation Project Owner: Yeshiva Pardas Yosef Project Location: 1 Veteran's Way, Saratoga Springs, NY 12866 Documents Preparation: Record Documents prepared by Victor Carl Cinquino Architect, Dated 18 January 2002, Revised 2-12-02 Evaluation Date: March 24, 2020; Revised 12/7/2021; Revised 1/11/2022 Final Revision 1/14/2022 Evaluation Code: 2020 International Building Code as adopted by New York State and 10 NYCRR Subpart 7-2 Documents Referenced For Code Evaluation: Record Documents prepared by Victor Carl Cinquino Architect, Dated 18 January 2002, Revised 2-12-02 Drawing A1.01 First Floor Plan—Dormitory Wing/Dormitory Room Drawing A1.02 Second Floor Plan—Dormitory Wing Drawing A1.03 Third Floor Plan—Dormitory Wing Drawing A2.01 First Floor plan—Sanctuary Wing Drawing A2.02 Second Floor—Sanctuary Wing Drawing A4.01—Elevations Drawing A4.02 Elevations Drawing A5.01 Building Sections Drawings A 6.01 Wall Sections Drawing A7.07 Schedules Evaluation Goals 1. Visual evaluation of the existing building to determine general alignment with the Record Documents provided. 2. Visual confirmation of the existing construction type,fire and smoke protection features, and fire protection systems. 3. General code review for height and area compliance for the construction type noted. 4. Determine the gross floor area of each existing dormitory room and the associated bathing, mechanical, lounge space, and restroom areas within the dormitory wing. 5. Determine the allowable occupant load for each space as a function of maximum floor area per occupant relative to the areas of the individual spaces noted and the desired or alternate use. 6. Review Chapter 10 Means of Egress requirements relative to the maximum allowable occupant load as determined by the 2015 IBC. Verdant Architecture �` PO Box 308 � Ballston Spa, NY 12020 �` (518)490-2040 General Building Evaluation Tax Map: 166.-1-21 Zoning: UR-1 Urban Residential w/Special Use permit Occupancy: A-3 w/R-2 Dormitory Construction Type: II-A Sprinkled: Yes (as confirmed by owner) Fire Alarm: Yes (as confirmed by owner) Monitored: Yes (as confirmed by owner) Required Separation: A-3/R-2= 1hr(Sprinkled) Existing Separation: A-3/R-2= 1hr Height and Area (Type II-A): Allowable Height (A-3): 85.00' (Sprinkled) Actual Height: <85.00' Allowable Height (R-2): 60.00' (Sprinkled 13R) Actual Height: <60.00' Allowable Stories(A-3): 4 Stories above grade(Sprinkled) Actual Stories: 3 Stories above grade Allowable Stories(R-2): 4 Stories above grade(Sprinkled 13R or non-sprinkled) Actual Stories: 3 Stories above grade sprinkled Allowable Area (A-3): 46,500 sf(Sprinkled) Actual Area: 1,783 sf Allowable Area (R-2): 24,000 sf(Sprinkled 13R or non-sprinkled) Actual Area: 9,308 sf(15T floor dormitory), 9,304 sf ea. (2"d and 3�d floor dormitory) General Building Evaluation conclusion:The existing building, upon a visual inspection and review of the Record Drawings, and record building inspector code analysis notes appears to meet or exceed allowable height and area requirements of the 2020 IBC. 2 OccupantLoads Maximum Floor Area Allowances Per Occupant: Dormitories: 50 gross Locker Rooms: 50 gross Mechanical Room: 300 gross Note: • Student lounge occupancy was determined using an occupant load of 50 gross per occupant • Alternate classroom use for dormitory rooms was determined with a net floor area and a classroom occupant load of 20 net per occupant, see note '3' below • Restroom occupancy was determined based on the number of fixtures Allowable Occupant Loads Per Area: Room Name Room Area (sf) Occupant Load Factor Maximum Occupancy Ritual Bath 963 gross 50 gross 24 Restroom N/A By Fixture Count 19 Mechanical Room 620 gross 300 gross 2 cr..,�„�..�,. �„�,�e55 �96s �S ADA Dormitory Rooms 317 gross 50 gross 6 (see note'2' below) Dormitory Rooms 317—324 gross 50 gross 6 (see note'1' below) Dormitory Rooms D221 341 gross 50 gross 6 (see note`1' below) & D321 n,,.-.,,:+.,...,n„ �n��� c/ ���aeL,..,l �-�KBSS �-�K953 v-�6EE�1^v�E�acrwrl �--�� Occupant Load Notes: 1. The maximum allowable occupancy for dormitory rooms is (6) six; however,the size and configuration of the room allows for a maximum of(5)five twin beds if considering adequate and safe circulation for the occupants. Room arrangements are open to alternate configurations with a maximum of(5)five twin bed footprints and six occupants (see attached room layout diagram). Examples:(5J five twin size beds=(5) occupants; (3J three twin size bunk beds=(6J occupants;(2J two twin size bunk beds and two twin size beds=(6J occupants. 2. The maximum allowable occupancy for ADA dormitory rooms is (6)six; however,the size and configuration of the room allows for a maximum of(3)three twin beds if considering adequate and safe circulation for the occupants. These could be arranged as (3)twin size bunk beds. If occupants are confined to wheelchairs,a (3)three twin bed arrangement is acceptable. 3 Egress Requirements R-2 Total Occupancy First Floor: 80 occupants(max. occupancy) Ritual Bath 24 occupants (auxiliary) Toilet/Urinal 19 occupants (auxiliary) Mechanical Room 2 occupants (auxiliary) ��'�c�►�Eer,:,�.�� ,�,,,.,..,., .,��i,...,,:�:,..-„i Dormitory rooms 80 occupants (16 rooms with up to 6 per room) Second Floor 85 occupants (max. occupancy) D201—D221 80 occupants (20 rooms with up to 6 per room) Third Floor 85 occupants (max. occupancy) D301—D321 80 occupants (20 rooms with up to 6 per room) bY7L� �CD Means of Egress Sizing Stai rways Means of egress capacity factor of 0.3 inches per occupant Level Occupant Load (OL) Required Capacity Existing Capacity (inches)(0.3 x OL) provided First Floor 80 maximum Not Required (no stair Not provided—direct egress) egress to exterior Second Floor 85 maximum 26 inches 40 inches at D229 52 inches at D224 Third Floor 85 maximum 26 inches 40 inches at D330 52 inches at D323 Other Egress Components Means of egress capacity factor of 0.2 inches per occupant Level Occupant Load (OL) Required Capacity Existing Capacity (inches)(0.2 x OL) provided First Floor 80 maximum 16 inches (36") 60" corridors/min. 36" Second Floor 85 maximum 17 inches (36") doors Third Floor 85 maximum 17 inches (36") 4 Number of Exits and Exit Access Doorways Egress based on occupant load and common path of egress travel distance Two exits or exit access doorways from any space shall be provided where the design occupant load or the common path of egress travel distance exceeds the values listed in Table 1006.2.1. Egress based on occupantload Each story and occupied roof shall have the minimum number of independent exits, as specified in Table 1006.3.1. A single exit or access to a single exit shall be permitted in accordance with Section 1006.3.2. the required number of exits or exit access stairways or ramps proving access to exits,from any story or occupied roof shall be maintained until arrival at the exit discharge or a public way. • Number of exits required (2)Two per floor • Number of existing exits provided (2)Two per floor Accessible Means of Egress The existing facility maintains an accessible means of egress from the first floor that is continuous to a public way and that consists of the following in accordance with Section 1009.2: 1. Accessible routes complying with 1104. 2. Interior exit stairways complying with Sections 1009.3 and 1023. 3. Exit access stairways complying with 1009.3. 4. Horizontal exits complying with Section 1026. 5. Areas of refuge complying with Section 1009.6.1-1009.6.4. Exit Access Travel Distance Limitations: exit access travel distance shall not exceed the values given in Table 1017.2. Table 1017.2 Exit Access Travel Distance Occupancy w/o Sprinkler System w/Sprinkler System (feet) (feet) A, E, F-1, M, R, S-1 200 250 Maximum exit access travel distance allowed for R-2 occupancy: 250 feet Maximum existing exit access travel distance: 163 feet Travel distance measured from the D101 Ritual Bath Door 105 to D152 Stair poor 117. 5 Evaluation Conclusion In reviewing the Record Documents provided for the existing dormitory wing of 1 Veterans Way, it is my interpretation that: • The allowable occupant load for each dormitory room shall be a maximum of(6)occupants per dormitory room. • •:�w ,. ,.FF:.,,,i�i.. ,.�„ w,,,�.. ��,....,i�i w,,,�....,.:�:,:��,�,...w�„ ,�,,,.� , Exceptions to the maximum of(6)occupants based on room area and intended use (i.e.wheelchair bound occupants)for dormitory rooms D222 and D223 and the three first floor accessible units have been noted in the "Occupant Loads" portion of the evaluation report. Diagrams for both the typical dormitory room and the ADA dormitory room have been provided. It should be noted that this evaluation was for the intended purpose of determining the allowable occupancy of each dormitory room and confirming that the existing means of egress system; exit, exit access, and exit discharge are adequate to necessitate the proposed maximum occupancy. As no work is being performed, no alterations are being made, and no changes are being proposed to the existing means of egress,the functionality, placement, and condition of: exit signs, handrails,guards, emergency egress lighting placement and illumination levels, panic and door hardware,elevator power supply and signaling devices,two-way communication systems, and any similarly required means of egress systems were not included as part of this review. It is assumed that these systems have been maintained by the owner and have been periodically inspected by the fire marshal. Please accept this evaluation as a means of updating the stated conditions noted on the Certificate of Occupancy dated 6/18/19 from "maximum 75 persons per floor" and "maximum 4 beds per room"to: • Dormitory Occupancy First Floor: o Maximum eighty(80) persons and a maximum of ' six(6) beds per room ••+�'���^^�'^••"'^ �'^�'"••�'"^�'�� �^'or three (3) beds;-e�-�-�as+��} per ADA room occupied by a wheelchair. • Dormitory Occupancy Second and Third Floors: o Maximum eighty-five (85) persons per floor and a maximum of E:.,��c� �:�^'�"��'� ^ ,�*^ six(6) beds ••+�'����^�'^••"'^ �'^�'�••�'�^�'�per room. Please contact me directly with any questions or comments. Kind regards, ��� Timothy A. Wade,Architect 6