Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20211138 35 Hyde St Area Variance Application
irurc vrn..c Vac1 —HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED— , t(1(:'t •5 jl CITY OF SARATOGA SPRINGS (Application#) \~ ` • $ ' ZONING BOARD OF APPEALS A ? , CITY HALL-474 BROADWAY (Date received) A.,•, SARATOGA SPRINGS, NEW YORK 12866-2296 • �� TEL: 518-587-3550 X2533 /NcQ9po4ATE0 `4,F www.saratoga-springs.org (Project Title) APPLICATION FOR: 1-1 INTERPRETATION, USE VARIANCE, Check if PH Required AREA VARIANCE AND/OR VARIANCE EXTENSION Staff Review APPL1CANT(S)* OWNER(S)(lf not applicant) ATTORNEY/AGENT EMILY AND JOACHIM BERGMANN Balzer & Tuck Architecture Name 35 HYDE STREET 468 Broadway Address SARATOGA SPRINGS, NY 12866 Saratoga Springs, NY 202-427-2877 (Emily) 518-580-8818 Phone 'n7-4942l11RR 1Arhiml achim@bergmannzwerdling.com Email emilvbergmann@gmail.com cnickerson@balzertuck.com Primary Contact Person: EApplicant [Owner ❑✓Attorney/Agent *An applicant must be the property owner, lessee,or one with an option to lease or purchase the property in question. Applicant's interest in the premises: ® Owner 0 Lessee ❑ Under option to lease or purchase PROPERTY INFORMATION 35 Hyde Street 165 73 2 56 I. Property Address/Location: Tax Parcel No.: - - (for example: 165.52—4—37) September 2015 UR-2 2. Date acquired by current owner: 3.Zoning District when purchased: single family residential UR-2 4. Present use of property: 5.Current Zoning District: 6. Has a previous ZBA application/appeal been filed for this property? El Yes(when? For what? ) ® No 7. Is property located within (check all that apply)?: 0 Historic District 0 Architectural Review District 0 500'of a State Park,city boundary,or county/state highway? Removal of existing front porch and construction of new, wrap-around front porch. 8. Brief description of proposed action: Modified driveways including a reduction in width of existing non-conforming driveway curb cuts. 9. Is there an active written violation for this parcel? ❑ Yes V No 10. Has the work, use or occupancy to which this appeal relates already begun? ❑Yes 0 No 11. Identify the type of appeal you are requesting(check all that apply): 0 INTERPRETATION(p. 2) El VARIANCE EXTENSION (p.2) 0 USE VARIANCE(pp. 3-6) 12 AREA VARIANCE (pp. 6-7) Revised 01/2021 ZONING BOARD OF APPEALSAPPL/CA77ON FORM PAGE 6 AREA VARIANCE—PLEASE ANSWER THE FOLLOWING(add additional information as necessary): Min. Front Yard Setback The applicant requests relief from the following Zoning Ordinance article(s) Max.Access Drive Lot Dimensional Requirements District Requirement Requested Minimum Front Yard Setback(Section 2.3(B)) 6.495' 3.89' Maximum Access Drive Lot Frontage (Section 6.2.7(B)(3)) 25% 36.08% Other: To grant an area variance,the ZBA must balance the benefits to the applicant and the health,safety,and welfare of the neighborhood and community,taking into consideration the following: I. Whether the benefit sought by the applicant can be achieved by other feasible means. Identify what alternatives to the variance have been explored (alternative designs, attempts to purchase land, etc.)and why they are not feasible. The benefit of the new front porch cannot be achieved by other feasible means. The owner's goal is to create a front porch where they are able to sit and interact with the neighborhood. The existing front porch is in poor condition and its depth (6'-3") is not sufficient for the use of chairs. The minimum dimension to allow for chairs is typically 8 feet;we are reducing this to 7'-9"along the front of the home. The existing access drive lot frontage is 66.25 feet. There isn't sufficient space in front of the existing garage to park a car which i wh h- •wn-r are 1•.kin• . .in .'n th- -xi ti • e cid • iv- _ . A a ..rt of thi .r.'-c e . cess driv- lo fronta•e will be reduced by 31.25 feet(47.1% reduction). 2. Whether granting the variance will produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. Granting the variance will not create a detriment to nearby properties or an undesirable change in the neighborhood character for the following reasons: Granting the variance for relief from the front yard setback will not be a detriment because a number of homes along this street are a similar distance to the property line. The increase in depth of the porch will allow for better engagement with activity on the sidewalk and street and will be a positive change in character of the neighborhood. The access drive lot frontage is proposing to reduce an existing non-conforming condition which will improve the character of the neighborhood. Revised 01/2021 ZONING Balm OF APPEALS APPLICATION FORM PAGE 7 3. Whether the variance is substantial. The requested variance is not substantial for the following reasons: The requested variance is not substantial because the proposal limits the nonconformity by 1.04 feet(21.1%)from the existing conditions. After measuring each of the existing front yard setbacks along Hyde Street,we have found nearly 70%of the homes are non-conforming with respect to front yard setback. See attached diagram. The access drive lot frontage variance request is not substantial because it will reduce an already existing non-conforming condition. 4. Whether the variance will have adverse physical or environmental effects on neighborhood or district. The requested variance will not have an adverse physical or environmental effect on the neighborhood or district for the following reasons: The variance will not have adverse physical or environmental effects on the neighborhood because the new porch and any connected sitework will include proper water management. 5. Whether the alleged difficulty was self-created(although this does not necessarily preclude the granting of an area variance).Explain whether the alleged difficulty was or was not self-created: The alleged difficulty presented by the front yard setback is self created however the owners have demonstrated their effort to limit their requested relief to the minimum required. The home is existing and the only means for further reducing their request would -b-Tro create a new pore that does not support their intended use of sitting in chairs. The access drive lot frontage is an existing condition which was in place prior to the current owners purchase. The desire to maintain this condition may be considered self-created however the owners have committed to reducing this width and non-con ormance o e grea es ex en prac ica an. s i permi use o e garage an. par ing area. Revised 01/2021 ZONING BOARD OF APPEALSAPPLIG4TION FORM PAGE 8 DISCLOSURE Does any City officer,employee,or family member thereof have a financial interest(as defined by General Municipal Law Section 809)in this application? 0 No ®Yes If"yes",a statement disclosing the name,residence and nature and extent of this interest must be filed with this application. APPLICANT CERTIFICATION I/we,the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Zoning Board of Appeals. By the signature(s)attached hereto, l/we certify that the information provided within this application and accompanying documentation is,to the best of my/our knowledge,true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. Furthermore, I/we hereby authorize the members of the Zoning Board of Appeals and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this appeal. 5.''"4k) )rte` Date:�'U�J. �v� l 0�14�-� (ap licant si ture t NM Date: )111 12, 11-1 (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature: _ Date: Owner Signature: Date: Revised 01/2021 i ,csr i CITY OF SARATOGA SPRINGS 12, _n r ZONING BOARD OF APPEALS C9 Holt. - 474 13ro-u4wa9 if Sa.ragngar SP-r v,.gy. New York,12866 Tel. 518-587—3550 X2533 t4 _wra-- r -gso.4rg INSTRUCTIONS APPEAL TO THE ZONING BOARD FOR AN INTERPRETATION, USE VARIANCE,AREA VARIANCE AND/OR VARIANCE EXTENSION APPLICATION REQUIREMENTS 1. ELIGIBILITY:To apply for relief from the City's Zoning Ordinance, an applicant must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. The Zoning Board of Appeals (ZBA) shall not accept any application for appeal that includes a parcel which has a written violation from the Zoning and Building Inspector that is not the subject of the application. 2. COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure a complete application. The ZBA will only consider properly completed applications that contain I original and 1 digital version of the following: ❑ Completed application pages I and 8, the pages relating to the requested relief(p. 2 for interpretation or extension, pp. 3-5 for use variance, pp. 6-7 for area variance), and any additional supporting materials/ documentation. **HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED** O Completed SEQR Environmental Assessment Form —short or long form as required by action. http://www.d ec.ny.gov/docs/permits_ej_operati o ns_p df/seafpartone.pd f O Detailed "to scale" drawings of the proposed project—folded and no larger than 24"x 36". Identify all existing and proposed structures, lot boundaries and dimensions, and the relationship of structures to the lot dimensions. Also, include any natural or manmade features that might affect your property (e.g., drains, ponds, easements, etc.). El Photographs showing the site and subject of your appeal, and its relationship to adjacent properties. 3. APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance". REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT. Check City's website (www.saratoga-springs.org) for meeting dates. Revised 01/2021 ZONING BOARD APPEAL APPLICATION INSTRUCTIONS PAGE 2 PUBLIC HEARING ADVERTISEMENT The Zoning Board of Appeals is required to hold a public hearing on each submitted application within ninety(90) days from when it is determined to be properly complete by City staff. City staff will prepare a legal notice for the public hearing and arrange to have the public hearing announcement printed in the legal notice section of a local publication at least 5 days before the hearing. PROPERTY OWNER NOTIFICATION Applicants are required to mail a copy of the public hearing legal notice to all property owners within the following distances from the boundaries of the land in question: Type of variance Distance for property owner notification Use variance 250 feet Area variance & Interpretation I00 feet This notice must be sent at least 7 days but not more than 20 days before the date of the public hearing. City staff will email a copy of the "property owner notification letter"to the applicant.The applicant must then send the notification letter to the nearby property owners.Applicants may not include any other materials in this mailing. The mailing must be certified by the U.S. Post Office. Prior to the public hearing,applicants must present the Post Office "certificates of mailing" to the ZBA. If "certificates of mailing" are not presented prior to the hearing, the hearing will be cancelled. Revised 01/2021 2021 LAND USE BOARD FEE WORKSHEET OPED Fees Type 2021 Fee Application to Zoning Board of Appeals[1][2] TOTAL JNARIANCE UseVariance $1100+$50/app AreaVariance-Residential $450 2 '$275/var+$50/app+$125eachadd9 variance AreaVariance-Multi-Family,Comm,Mixed-Use -$660/var+$50/app+5200 eachaddi variance Interpretations —$550+$50/app Post-Work Application Fee Add 50%App fee+550/app Variance extensions '50%ofAppfee+$50/app Application to Design Review Commission[1] TOTAL #STRUCTURE Demolition $385 Residential Structures Principal $55 Accessory $55 Extension $35 Modification $55 Multi-Family,Comm,Mixed-Use Structures Sketch $165 Principal - $550 Extension $200 Modification $330 Multi-Family,Comm,Mixed-Use Accessory,Signs,Awnings Principal $140 Extension - $75 Modification $140 Post-Work Application Fee Add 50%App fee Application to Planning Board[1] TOTAL #STRUCTURE Special Use Permit[2] $990+$50/app Special Use Permit-extension $330 Special Use Permit-modification[2] - 5450+550/app SitePlan Review-incl.PUD: Sketch Plan $330 Residential $330+$200/unit Residential-extension $200 Residential-modification $400 Non-residential $650+5130/l00osf Non-Residential-extension $300 Non-Residential-modification $650 Subdivision-incl.PUD: TOTAL RLOTS Sketch Plan L I $330 Preliminary Approval[2] Residential:1-5 lots $660+$50/app Residential:6-10 lots $990+$50/app Resldential:11.20 lots $1320+$50/app Residential:21+lots $1650+50/app Residential-extension $330 Final Approval[2] Residential $1320+$175/lot+$50/aPR Non-Residential $2000/lot+$50/app Final Approval Modification[2] Residential $330+550/app Non-Residential $550+550/app Final Approval Extension Residential $135 Non-Residential $330 Other: TOTAL BLOT/ACRE Post-Work Application Fee Add 50%App fee Lot Line Adjustment $350 Letter of Credit-modification or extension $440 Letter of Credit-collection uptol%ofLoC Recreation Fee $2000/lotorunit Land Disturbance $660+555/acre SEORA EIS Review(Draft&Final) TBD Legal Noticing if PB requires Pubic Hearing $50/app [1] Fees are based on per structure,exceptwherenoted. $450.00 TOTAL DUE [2] Legal ad required;includes City processing and publishing For Administrative Use Total Paid at Intake Revised Fee Balance Due / J. Balance Paid Staff approval 6 41 *Prrg I � mo ....,..i- if n � ;- ... a _ ,_____ _1 r 1 32 HYDE STREET-EXISTING HYDE STREET(EAST)ELEVATION 32 HYDE STREET-EXISTING YARD(SO UTH/WEST)ELEVATIONS l °fi�. s f# t col"y1 - I`• ry,f/(/ .�kr +7 e..: [32 HYDE STREET-EXISTING HYDE STREET(EAST)ELEVATION 32 HYDE STREET-EXISTING PARTIAL NORTH ELEVATION BALZER EN TUCK "'BROADWAY SARATOGA SPRINGS NY 12866 Existing Conditions Photographs BERGMANN RESIDENCE Architecture P518.580.8818 F518.580.8824 BALZERTUCK.COM BTA PROJECT NO 1908 10/21 35 HYDE STREET SARATOGA SPRINGS,NY 35'-2,/2' ,9'_11" 35'-2,/2" ,9-11' • •PROPERTY LINE • PROPERTY LINE I' EXISTING FRONT :11:4138 I I I I I I I I I I I I I I I I Ilii 78 PORCH EXISTING ���■.����■E<TG ROOF■■■��■,,��Y■Y��i: 18 6 x 6' 3 N BATH -::4 BELOW■iiir''r■�■■ 0 lid■�■�■ ilii o■�"' • lirH i::■ .............I:.;_ �� :e ECTG ROOF��:: I MEM :. eELow. 1� ��� �Ii rinllIM' "WallW 1%1 I EXISTING �a- -EXISTING g_ _ MUDROOM EXISTING =� -BEDROOM I I I DVI '�.-IXISTING■E L ,2_4"x,2-i6 T x,3'=o"' YJ14 ,9'_3"x12'_3" PLAYROOM BEDROOM 3— N , III M a-� o) Lop 6—0" , EXISTING GARAGE _ i l —m.. 25'-3"x21'-6 l • IXISTI NG ; _=— — .I � 1■mI�� KITCHEN Q 7-9'x14'-4'. , �� _EXISTING EXISTING III EXISTING _ BEDROOM --/ DINING I It BEDROOM 2 —EXISTING 16-4' ' O�x 0 - 8'-0"x 16'__6 10 i0'x 9'- EXISTINGBEDROOM 20'-9"x„'- ' 11' 0 11 -9 1111111■L ■i ■■1 L.- , 0 LOFT E I.. ..- EXIEt ••I.,„ iiII• 9 ,0x20'-,0" EXISTING WIC 4. ,3 0x,3-0 T ! i " ■■i L51UOM co "x,7'-9" - 1111 jEXISTING ■■' - ul DINING' All _ m 16-2"x11'./g -7" _EXISTING_® I BATH N r1r ,3'-0"x,5'-0'® oN I _EXISTING MASTER N ■ 8 i!i! !I!mi LIVING ■,-'I. A J 11111111111111®�I BEDROOM x3� ll IX NG EXISTING BATH =0 x -. oiiIlIl I - 1��3' 0'x II0" OExisting First Floor Plan O Existing Second Floor Plan 1/8"=[1'-0" 1/8"=1'-0" BALZEREy TUCK 468 BROADWAY•SARATOGA SPRINGS•NY•12866 Existing Floor Plans BERGMANN RESIDENCE Architecture P518.580.8818.F 518 580 8824.BALZERTUCK.COM BTA PROJECT NO'. 1908 11/10/21 1 35 HYDE STREET SARATOGA SPRINGS,NY 0','2' 4 : , ,e,„ ZONING INFORMATION ce�` A°°Ta°wE , wm� P° F, • .., Zesi UCng: _� A°7 _ `,o ' 7A VI PT BORING DRIVEWAY BOLO TE,PEPPER EMS SGMN°REPT CON FO°NPIG I, N........iriliWitgatiMbilnitiftWKWIr al RELINDIL S PR EP T°,n MI ®�°°° Pa°�•° �I°•°�nT°�T°°xT°E�IxxI•°T°°,.°.°ET°I•°IP n°°R,°oA �.�E® R. P.M LINEINDILFTB Ir 'r»Y• a :� sasTo°e°a°EG T „OP gym . -___ .k PPP T :1111111,0 _�, ��n -�., __ --_- .'�.'. °tiop,��rxoes0s muwEre - -e • LIMO CRTIVIT I ilia LOT SZE 91 SF Dm•°°n up-2 n � , 71:i 1;1::•,::ii 01 , 11..,00.11 1 1,.„ i I_--- ,IlIl --- - a ®°� �-- � V I MG i , EXISTING ACCESS DANE PAPP,SPE DIAGRAM =T: °PP ,aN \ IL. I • _-1 pI - BALZER[S TUCK 4g8 BROADWAY.SARATOGA SPRINGS.NY•12866 Existing and Proposed Site Diagrams BERGMANN RESIDENCE Architecture P518.580.8818.BALZERTUCK.CCM•F 518.580.8824 BTA PROJECINC.1908 11/10/21 35 HYDE STREET SARATOGA SPRINGS,NY 38'-8,/2" W G • • mo 0 m II DRIVMODEWAY Y 'I—�' DI g y pil ig ❑a II m co NEW FRONT PORCH • 8'-0 • - I LINE OF ROOF OVERHANG ABOVE E MODIFIED51' I PWDR� •t7-71/ ° DRIVEWAY G MUDROO ENTRY FOYER l F:, '1j ,5'-0..x,2'-3" 4 I -� �� M 1 . GGARAGEI 1111 '°' °x,2-3 I Lil *5�3��x2,'-6 ppp N.= ■, ice. 111 a --F • • 117NGI ■ 1•'-3"x,6-3" I 41 111=■MI 111=■•I' ■■■ 1I I F7 o MEM, EXERCISE/GUEST ROOM II • u I " II _ „_ NEW BILCO 13-0x17-9" —H1 .mI ImI -II KITCHEN/DINING NEW PATIO 6 2x 229 ' 20 Ox 27'-0' I I t 1� AL I ®RATHI 1 •_k a 1. illi • I =1 I NEW DOOR,LANDING, O EXISTING POOL AND STEPS TO BACKYARD i— BALZEREy TUCK 468 BROADWAY SARATOGA SPRINGS-NY-12888 Proposed First Floor Plan BERGMANN RESIDENCE Architecture P518.580.8818 F 518.580.8824 BALZERTUCK.COM BTA PROJECT NO'. 1908 11/10/21 I 35 HYDE STREET SARATOGA SPRINGS,NY 0','2' 4' co r o Z co 7c,-00 ] PI EL•W ..o.,F:FL.:W ■■■■■■■■■■■■■■■ `—.. — I- 1 Irjrilillii-1-1- 1611k 1 BEDROOS 50�� ® �TH 1159 13M0 ® MASTERBEDROOM ❑l, 19'-3"x16'-2' I 1 _ I �I13 ox610 I E � �®\ 1I IWInI L - L J MASTER HALL I , L x\ II 1 tir I= _ I _Il ©�0IM I II HALL HERS WIC ' I I ❑ 8'_0'x3T-8' 12-5'x13'_2' I II•_ I• � I I ❑ BEDROOM 2 ME _.\--,-.--:1-/ .1 �' 13-0"x13'-6 ■■ \ FLIX ROOM I IMIE__ � I I U LAUNDRY ROOM,I I ry� I I 13'-0"x11'-6'_ i II_ -- 'I BALZER NI TUCK 468 BROADWAY•SARATOGA SPRINGS NY 12866 Proposed Second Floor Plan BERGMANN RESIDENCE Architecture P 518 580 8818.F 518.580.8824-BALZERTUCK.COM BTA PROJECT NO'. 1908 11/10/21 1 35 HYDE STREET SARATOGA SPRINGS,NY 0'1'2' 4 'II.82,. NEW ASPHALT SHINGLE ROOF,TYP. NEW COMPOSITE ROOF TRIM,TYP. NEW GUTTERS - - EXTG T/PLATE 2ND FLF 117' 71/2" •� �� LL NEW PELLA IMPERVIA FIBERGLASS WINDOWS,TYP. NEW COMPOSITE WINDOW TRIM,TYP. ® G ITA �i NEW PREMIUM VINYL LAP SIDING,TYP. 12" / NEW STANDING SEAM METAL ROOF AT PORCH 3 - - . . AND GARAGE EXTG T/FINISH 2ND FLF • 10M-71/2" • n i■ in n �. _ I'- NEW LIGHT FIXTURE --�� NEW FIBERGLASS n�■ In nin Iii- ■=i■ ��■ NEW WOOD BRACKETS COLUMNS,TYP. NEW GARAGE DOORS m NEW ALUMINUM HANDRAIL I II!. III II NEW 1x COMPOSITE TRIM,TYP. �' r - - u■��■i'� NEW 1x COMPOSITE BAND TRIM,TYP. - EXTG 100' •In NEW COMPOSITE LATTICE AT UNDERSIDE OF DECK,WRAP AROUND ENTIRE PERIMETER OF PORCH NEW MAHOGANY DECKING AND STEPS L i BALZER[ TUCK 468 BROADWAY•SARATOGA SPRINGS-NY-12866 Proposed East Elevation BERGMANN RESIDENCE Architecture P 518 580 8818.F 518 580 8824.B LZERTUCK.COM BTA PROJECT NO'. 1908 11/10/21 1 35 HYDE STREET SARATOGA SPRINGS,NY 0'l'2' 4' NEW ASPHALT SHINGLE ROOF,TYP. - <TG T/PLATE-2ND FLR 117-71/2" -� \ ®�®i®� �� NEW PELAIMPERVAFIBERGLASS f �/ WINDOWS,TYP. NEW COMPOSITE WINDOW TRIM,TYP. - IL 12' 12' NEW STANDING SEAM METAL ROOF NEW PREMIUM 33/4" 33/4' EXTG T/FINIS H-2ND FLR� VINYL LAP SIDING 1-02, 71/2, - NEW ix COMPOSITE TRIM,TYP. - - , , E55} . T_ ,„ -PD - NEW FIBERGLASS COLUMNS NEW CULTURED STONE/CMU _ c NEW ALUMINUM HANDRAIL _ PATIO PAVERS OVER SAND ANC A ni CRUSHED GRAVEL BASE [NI_ ill .29'5'-- NEW ix COMPOSITE BAND TRIM,NP. _ _ IXTG T/FINISH-iS0 FLR 6 2411 11 1 NEW COMPOSITE LATTICE AT UNDERSIDE OF DECK,WRAP AROUNC ENTIRE PERIMETER OF PORCH NEW DOG DOOR NEW ALUMINUM WALL MOUNTED HANDRAIL ili BALZER EN TUCK 468 BROADWAY•SARATOGA SPRINGS.NY 12866 Proposed South Elevation BERGMANN RESIDENCE Architecture P518.580.8818.F 518 580 8824.BALZERTUCK.COM BTA PROJECT NO'. 1908 11/10/21 1 35 HYDE STREET SARATOGA SPRINGS,NY 0'1'2' 4' 12 NEW ASPHALT SHINGLE ROOF,TYP. wwwow E, NEW GUTTERS _� i EXTG T/PLATE-21JD FLR 1 11771/2" NEW GUTTERS NEW PELLA IMPERVIA FIBERGLASS WINDOWS,TYP. �[ IIA `` 12" NEW STANDING SEAM METAL NEW PREMIUM VINYL n I�iiifff��I 3' ROOF AT PORCH AND GARAGE LAP SIDING _ EXTG T/FINISH-2ND FLR 1. NEW PREMIUM — 1(U'-71/2" NEW 1x COMPOSITE TRIM,TYP. VINYL LAP SIDING NEW COMPOSITE WINDOW TRIM,TYP. — II! / NEW FIBERGLASS COLUMNS,TYP. C ��� �� NEW ALUMINUMDECKINHANDRAIL,TYP. m NEW MAHOGANY DECKING AND NEW STEPS AND HANDRAIL TO MATCH PORCH 71 / — STEPS AT FRONT PORCH EXTG T/FINISH-1ST FLR NEW 1x COMPOSITE BAND TRIM,TYP. — ,. P IL_ . 1 _ _�� r j 100'-0" �- NEW COMPOSITE ix TRIM BOARD I BALZER NI TUCK 468 BROADWAY-SARATOGA SPRINGS NY 12866 Proposed West Elevation BERGMANN RESIDENCE Architecture P518.580.8818.F 518 580 8824.BALZERTUCK.COM BTA PROJECT NO'. 1908 11/10/21 1 35 HYDE STREET SARATOGA SPRINGS,NY 0 1'2' 4' NEW ASPHALT SHINGLE ROOF,TYP. — --------- ---- -- - - -- - - -_ _ _ EXTG T/PLATE-2ND FLR NEW 1x COMPOSITETRIM �,'� pill ESPERVIAFIBERGLASS 117'-71/2w NEW STANDING SEAM METAL WINDOWS ROOF AT PORCH AND GARAGE 12" j 33/4' NEW PREMIUM VINYL _ _ EXTG T/FINISH_2ND FLR NEW FIBERGLASS _ LAP SIDING,TYP. 1(U'-71/2" COLUMNS,TYP. MI NEW WOOD BRACKETS a xxxi / ■■��-' NEW COMPOSITE WINDOW TRIM,TYP. v NEW ALUMINUM HANDRAIL 4'I ��n ,�� ;;; mid NEW 1x COMPOSITE BAND TRIM,TYP. __A. NEW MAHOGANY DECKING y _ _ EXTG T/FINISH-1ST FLR AND STEPS AT FRONT PORCH \ I; 100'-V" —I BALZER EN TUCK 468 BROADWAY•SARATOGA SPRINGS-NY-12866 Proposed North Elevation BERGMANN RESIDENCE Architecture P518.580.8818.F 518 580 8824.BALZERTUCK.COM BTA PROJECT NO'. 1908 11/10/21 1 35 HYDE STREET SARATOGA SPRINGS,NY 0'1'2' 4' .2 \ 3.33 ri 10 imi =, I_I [11 # m_:„ _ _ _____ r# - _ �LI II 11 - - r �III r - 0?lL -i I - ■ ■ II - E _ 1%""A.*-G' ... 11 immis . 1 BALZER NI TUCK 468 BROADWAY SARATOGA SPRINGS NY 1286£; Proposed Perspective from Hyde Street BERGMANN RESIDENCE Architecture P518.580.8818 F 518 580 8824 BALZERTUCK.COM BTA PROJECT NO'. 1908 11/10/21 1 35 HYDE STREET SARATOGA SPRINGS,NY - - - -- y • d Li rz �, idol H 15 0 ,_® - s J II , • U a /if��� `; NOTE'.DIMENSIONS REFLECT FIELD DIMENSIONS TAKEN 1 A BY BALZER&TUCK ARCHITECTURE INDICATING DISTANCE FROM HYDE STREET TO CLOSEST FACE OF WALL OR V. --- COVERED PORCH FLOOR. RED HATCH INDICATES HYDE��STREET ' PROPERTIES WITHIN 10'REQ D FRONT YARD SETBACK. 0 ,, : SITE � ". f: z _ 35 HYDE STREET i / , , 8 4 / 6 w 8i w I R I yt 19'91/2.._.. MEI • 22 l 1 7 , . '. Irl I-� L f° e Id I IN_ B CJ I ,I n In n �I W 'z. _ ,III HI;q i -_ 16•_0••EXISTING ._ 15'-41/4"PROPOSED [ 14'-103/4. _ BALZER NI TUCK 468 BROADWAY SARATOGA SPRINGS NY 12866 Neighborhood Context BERGMANN RESIDENCE Architecture P518.580.8818.F 518.580.8824 BALZERTUCK.COM BTA PROJECT NO'. 1908 11/10/21 35 HYDE STREET SARATOGA SPRINGS h.'� LINE OF CLOSEST HOME TO STREET • REQUESTED SETBACK PROPOSED FOOTPRINT OF ' EXISTING HOME AND NEW • 10'REQUIRED SETBACK - WRAP-AROUND PORCH • HYDE STREET . - - - - SITE 32 HYDE STREET r • i i SCALE'.1/32"=1'-0" BALZERNI TUCK 468 BROADWAY•SARATOGA SPRINGS•NY•12866 Hyde St Front Yard Setbacks Diagram BERGMANN RESIDENCE Architecture P 518.580.8818-F 518.580.8824-BALZERTUCK.COM BTA PROJECT NO'. 1908 10/21 35 HYDE STREET SARATOGA SPRINGS,NY Short Environmental Assessment Form Part 1 -Project Information Instructions for Completing Part 1—Project Information. The applicant or project sponsor is responsible for the completion of Part 1. Responses become part of the application for approval or funding,are subject to public review,and may be subject to further verification. Complete Part 1 based on information currently available. If additional research or investigation would be needed to fully respond to any item,please answer as thoroughly as possible based on current information. Complete all items in Part 1.You may also provide any additional information which you believe will be needed by or useful to the lead agency;attach additional pages as necessary to supplement any item. Part 1—Project and Sponsor Information Name of Action or Project: Bergmann Residence Project Location(describe,and attach a location map): 35 Hyde Street,Saratoga Springs,NY Brief Description of Proposed Action: Removal of existing front porch and construction of new,wrap-around front porch. Modified driveways including a reduction in width of existing non-conforming driveway curb cuts. Name of Applicant or Sponsor: Telephone: 518-580-8818 Balzer&Tuck Architecture E-Mail: cnickerson@balzertuck.com Address: 468 Broadway City/PO: State: Zip Code: Saratoga Springs NY 12866 1. Does the proposed action only involve the legislative adoption of a plan,local law,ordinance, NO YES administrative rule,or regulation? If Yes,attach a narrative description of the intent of the proposed action and the environmental resources that ❑ may be affected in the municipality and proceed to Part 2. If no,continue to question 2. 2. Does the proposed action require a permit,approval or funding from any other government Agency? NO YES If Yes,list agency(s)name and permit or approval: 0 ❑ 3. a.Total acreage of the site of the proposed action? 0.288 acres b.Total acreage to be physically disturbed? 0.062 acres c.Total acreage(project site and any contiguous properties)owned or controlled by the applicant or project sponsor? 0.288 acres 4. Check all land uses that occur on,are adjoining or near the proposed action: Urban ❑ Rural(non-agriculture) ❑ Industrial Commercial m Residential(suburban) ❑Forest ❑ Agriculture ❑ Aquatic m Other(Specify): High School to the South ❑Parkland Page 1 of 3 SEAF 2019 5. Is the proposed action, NO YES N/A a. A permitted use under the zoning regulations? ❑ ❑ ❑ b. Consistent with the adopted comprehensive plan? ❑ ❑ ❑ NO YES 6. Is the proposed action consistent with the predominant character of the existing built or natural landscape? ❑ ❑ 7. Is the site of the proposed action located in,or does it adjoin, a state listed Critical Environmental Area? NO YES If Yes,identify: ❑� ❑ NO YES 8. a. Will the proposed action result in a substantial increase in traffic above present levels? ❑ ❑ b. Are public transportation services available at or near the site of the proposed action? ❑ ❑ c. Are any pedestrian accommodations or bicycle routes available on or near the site of the proposed ❑✓ ❑ action? 9. Does the proposed action meet or exceed the state energy code requirements? NO YES If the proposed action will exceed requirements,describe design features and technologies: ❑ ❑ 10. Will the proposed action connect to an existing public/private water supply? NO YES If No,describe method for providing potable water: ❑ ❑ 11. Will the proposed action connect to existing wastewater utilities? NO YES If No,describe method for providing wastewater treatment: ❑ ❑ 12. a.Does the project site contain,or is it substantially contiguous to,a building,archaeological site,or district NO YES which is listed on the National or State Register of Historic Places,or that has been determined by the ❑ El of the NYS Office of Parks,Recreation and Historic Preservation to be eligible for listing on the State Register of Historic Places? b.Is the project site,or any portion of it,located in or adjacent to an area designated as sensitive for ❑✓ ❑ archaeological sites on the NY State Historic Preservation Office(SHPO)archaeological site inventory? 13. a. Does any portion of the site of the proposed action,or lands adjoining the proposed action,contain NO YES wetlands or other waterbodies regulated by a federal,state or local agency? ❑✓ ❑ b. Would the proposed action physically alter,or encroach into,any existing wetland or waterbody? ✓❑ ❑ If Yes,identify the wetland or waterbody and extent of alterations in square feet or acres: Page 2 of 3 14. Identify the typical habitat types that occur on,or are likely to be found on the project site.Check all that apply: EShoreline ❑ Forest ❑Agricultural/grasslands ❑ Early mid-successional ❑Wetland m Urban Suburban 15. Does the site of the proposed action contain any species of animal,or associated habitats,listed by the State or NO YES Federal government as threatened or endangered? ❑✓ ❑ 16. Is the project site located in the 100-year flood plan? NO YES ❑✓ ❑ 17. Will the proposed action create storm water discharge,either from point or non-point sources? NO YES If Yes, ❑ ✓❑ a. Will storm water discharges flow to adjacent properties? ❑✓ ❑ b. Will storm water discharges be directed to established conveyance systems(runoff and storm drains)? n ❑ If Yes,briefly describe: 18. Does the proposed action include construction or other activities that would result in the impoundment of water NO YES or other liquids(e.g.,retention pond,waste lagoon,dam)? If Yes,explain the purpose and size of the impoundment: ❑ ❑ 19. Has the site of the proposed action or an adjoining property been the location of an active or closed solid waste NO YES management facility? If Yes,describe: 20.Has the site of the proposed action or an adjoining property been the subject of remediation(ongoing or NO YES completed) for hazardous waste? If Yes, describe: on I CERTIFY THAT THE INFORMATION PROVIDED ABOVE IS TRUE AND ACCURATE TO THE BEST OF MY KNOWLEDGE Applicant/sponsor/name: Michael J Tuck,AIA Date: November 12,2021 Signature: Title:Architect PRINT FORM Page 3 of 3