Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20211076 37 Clark Air Conditioner Unit Application
**HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED** jFOROFFICE USEl PryoC:1 �. ›Ys' r CITY OF SARATOGA SPRINGS (Application#) =N DESIGN REVIEW COMMISSION ,"%' ) • CITY HALL-474 BROADWAY (Date received) J t' x .:"` SARATOGA SPRINGS, NEW YORK 12866-2296 °RPORnTEo TEL: 518-587-3550 X2533 www.saratoga-springs.org (Project Title) APPLICATION FOR: ARCHITECTURAL/HISTORIC REVIEW Staff Review APPLICANT(S)* OWNER(S) (if not applicant) ATTORNEY/AGENT Name Michael Engelbrecht Address 37 Clark St#3 Saratoga Springs, NY 12866 Phone 571-258-9116 / / / Email michael.engelbrecht@pcg.com Identify primary contact person: 8 Applicant 0 Owner 0 Attorney/Agent An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant's interest in premises: III Owner 0 Lessee 0 Under option to lease or purchase PROPERTY INFORMATION Property Address/Location: 37 Clark St#3 Tax Parcel #: -(for example: /65.52—4—37) Date Acquired by Owner: Current Zoning District: Property use: 0 Residential 0 Non-residential/mixed-use Type of Review: 0 Architectural e Historic 0 Extension/modification (of current approval) Summary description of proposed action: Install of a Mitsubishi combination heat pump and condenser for a split system. The existing wall mounted air conditioner units and sleeves will be removed and holes patched/painted with matching stucco. The proposed location of the condenser unit would be wall mounted on the south exterior next to unit#4's existing condenser. Lines to be covered by a trim cover painted to match the exterior. Has a previous application been filed with the DRC for this property? IM No 0 Yes—date(s)? -App. No.(s)? Revised 01/2021 **A "complete" application consists of 1 hard copy(original) , and I electronic copy of application &ALL other materials as required below: New Construction/Additions ❑ Color photographs showing site/exterior details of existing structures and adjacent properties ❑ Site plan,drawn to scale,showing existing&proposed construction, property lines&dimensions, required &proposed setbacks&lot coverage,site features(fences,walks,trees,etc.);on no larger than 2'x3'sheet—smaller preferred if legible ❑ Elevation drawings showing design of all sides of existing&proposed construction—label dimensions,colors, materials, lighting(fixture &lamp type,wattage),etc. -include compass bearing&scale; no larger than 2'x3'sheet—smaller permitted if legible ❑ Floor plans for proposed structure;on sheet no larger than 2'x3'—smaller permitted if legible ❑ Product literature,specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) ❑ Color photographs showing site/exterior details of existing structures and that illustrate affected features ❑ Elevation drawings showing all sides of existing&proposed construction—label dimensions,colors, materials, lighting(fixture&lamp type,wattage),etc. -include compass bearing&scale; no larger than 2'x3'sheet—smaller permitted if legible ❑ Product literature,specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts only (Front setbacks:UR-I &INST-1-1TR=30';UR-4=25';UR-2,UR-3&NCUD-I=10') - Installation, removal or change in material of drive-and walkways - Installation or removal of architectural, sculptural or vegetative screening over 3' in height - Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2' diameter) For any of above: ❑ Color photographs showing site/exterior details of existing structures,and of adjacent properties ❑ Site plan showing existing&proposed construction: include property lines&dimensions, required &proposed setbacks&lot coverage,site features(fences,walks,trees,etc.) street names,compass bearing&scale; no larger than 2'x3'sheet—smaller preferred if legible ❑ Product literature,specifications and samples of proposed materials and colors Signage/Awnings ❑ Color photographs showing site/exterior details of existing structures,and adjacent properties ❑ Plan showing location of proposed sign/awning structure on building/premises: no larger than 11"x17" ❑ Scaled illustration of proposed sign/awning structure and lettering(front view&profile): include all dimensions of structure;type, dimensions and style of lettering or logo;description of colors, materials, mounting method and hardware ❑ Descriptions,specifications of proposed lighting including fixture&lamp type,wattage, mounting method,and location ❑ Product literature,specifications and samples of proposed materials and colors Demolition ❑ Color photographs showing site/exterior details of existing structures,and of adjacent properties ❑ Site plan showing existing and any proposed structures-include dimensions,setbacks,street names,compass bearing,and scale ❑ Written description of reasons for demolition and, in addition: ❑ For structures of"architectural/historical significance",demonstrate"good cause"why structure cannot be preserved ❑ For structures in an architectural district that might be eligible for listing on National Register of Historic Places,or for a "contributing"structure in a National Register district(contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities ❑ Color photographs showing site/existing structures, and of adjacent properties ❑ Site plan showing existing and proposed structures: include dimensions,setbacks,street names,compass bearing,and scale ❑ Scaled illustration of proposed structures: include all dimensions;colors, materials, lighting, mounting details ❑ Consult Article 240-12.22 of the City's Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 01/2021 Request for extension of current approval ❑ Identify date of original DRC approval: Current expiration date: Org.App. No. ❑ Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEQR Environmental Assessment Form ❑ Applicants proposing the following must complete"Part I" of the SEQR Short Environmental Assessment Form (available here: http://www.dec.ny.gov/docs/perm its_ej_operations_pdf/seaf partone.pdf): - Construction or expansion of a multi-family residential structure (4 units +) - Construction or expansion (exceeding 4,000 sq.ft.gross floor area)of a principal or accessory non-residential structure -Telecommunications facility, radio antennae, satellite dishes - Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? E No 0 Yes- If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification I/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Commission. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review of the Zoning Code of the City of Saratoga Springs. Digitally signed by Michael Engelbrecht Michael Engelbrecht Reason lamapprovingthisdowment 1 Date:2021.10.19 1218:49-04'00' Date: (applicant signature) Date: (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature: Date: Owner Signature: Date: Revised 01/2021 Nry 0G � CITY OF SARATOGA SPRINGS DESIGN REVIEW COMMISSION `, City Hall 474 Broadway Saratoga Springs, New York 12866 ryc°"PORATEt) Tel:518-587-3550 x2533 www.saratoga-springs.org INSTRUCTIONS ARCHITECTURAL/HISTORIC REVIEW APPLICATION I. ELIGIBILITY:An applicant to the Design Review Commission for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2. COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRC will only consider properly completed applications that contain 1 original and 1 digital version of the application and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!! 3. ACTIONS REQUIRING REVIEW: Architectural Review District Historic Review District • any exterior changes that require a building permit • Installation or exterior change to a structure requiring a • any change in exterior building materials building or demolition permit • a new, or change to an existing, sign or sign structure • any material change to exterior of a structure including: • demolition of a structure - addition or removal of exterior architectural features - installation, removal or material changes to exterior building elements such as roof, siding, windows, doors, Within a non-residential zoning district: • a change in exterior building color porches, etc. • installation of an awning - enclosure or screening or buildings openings such as windows, doors, porches, etc. - installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. • Within a front yard setback: - installation, removal or material changes to drive- or walkways - installation or removal of architectural, sculptural or vegetative screening that exceeds 3' in height - installation of accessory utility structures or radio/satellite transmission/reception devices over 2' in diameter • a change in exterior building color within a non- residential zoning district • a new, or change to an existing, sign or awning • installation of telecommunications facilities Note—Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review. Revised 01/2021 4. DESIGN GUIDELINES: The Design Review Commission will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: • Height— consistent with historic form and context of site and surrounding properties • Scale— relationship of structure and its architectural elements to human size, form, perception • Proportion — relationship among building elements including front facade, windows, and doors • Rhythm— pattern resulting from repeating building elements such as door/window openings, columns, arches, and other facade elements • Directional Expression — compatibility with horizontal &vertical expression of surrounding structures • Massing & Open Space— relationship of structure to open space between it and adjoining buildings • Setback—compatibility with surrounding structures • Compatibility of the following with surrounding structures/properties: - Major building elements (storefronts, doors, windows, roof) - Building materials - Color— (in non-residential zoning districts only) 5. DECISIONS: The Design Review Commission may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of the filing date unless the project has sufficiently commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6. AGENDA DATE: Check City's website (www.saratoga-springs.org) for meeting dates. Applications are placed on an agenda on first-come, first-served basis as determined by the completeness of the application. 7. APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance". REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT. ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Commission responsibilities may be found in the City's Zoning Ordinance available in City Hall and on the City's web site at http://www.saratoga-springs.org/544/Zoning-Ordinance. Revised 01/2021 2021 LAND USE BOARD FEE WORKSHEET OPED Fees Type 2021 Fee Application to Zoning Board of Appeals[1][2] TOTAL #VARIANCE Use Variance $1100+$50/app Area Variance-Residential $275/var+$50/app+$125 eachadd'I variance Area Variance-Multi-Family,Comm,Mixed-Use $660/var+$50/app+$200 eachadd'I variance Interpretations $550+$50/app Post-Work Application Fee Add 50%App fee+$50/app Variance extensions 50%ofApp fee+$50/app Application to Design Review Commission[1] TOTAL #STRUCTURE Demolition I $385 Residential Structures Principal $55 Accessory $55 Extension $35 Modification $55 Multi-Family,Comm,Mixed-Use Structures Sketch $165 Principal $550 Extension $200 Modification $330 Multi-Family,Comm,Mixed-Use Accessory,Signs,Awnings Principal $140 Extension $75 Modification $140 Post-Work Application Fee Add 50%App fee Application to Planning Board[1] TOTAL #STRUCTURE Special Use Permit[2] $990+$50/app Special UsePermit-extension $330 Special UsePermit-modification[2] $450+$50/app Site Plan Review-incl.PUD: Sketch Plan $330 Residential $330+$200/unit Residential-extension $200 Residential-modification $400 Non-residential $660+$130/1000 sf Non-Residential-extension $300 Non-Residential-modification $650 Subdivision-incl.PUD: TOTAL #LOTS Sketch Plan I $330 Preliminary Approval[2] Residential:1-5 lots $660+$50/app Residential:6-10 lots $990+$50/app Residential:11-20 lots $1320+$50/app Residential:21+lots $1650+50/app Residential-extension $330 Final Approval[2] Residential $1320+$175/lot+$50/app Non-Residential $2000/lot+$50/app Final Approval Modification[2] Residential $330+$50/app Non-Residential $550+$50/app Final Approval Extension Residential $135 Non-Residential $330 Other: TOTAL #LOT/ACRE Post-Work Application Fee Add 50%App fee Lot Line Adjustment $350 Letter of Credit-modification or extension $440 Letter of Credit-collection up to 1%ofLoC Recreation Fee $2000/lotorunit Land Disturbance $660+$55/acre SEQRA EIS Review(Draft&Final) TBD Legal Noticing if PB requires Public Hearing $50/app [1] Fees are based on per structure,except where noted. $0.00 TOTAL DUE [2] Legal ad required;includes City processing and publishing For Administrative Use Total Paid at Intake Revised Fee Balance Due / / Balance Paid Staff approval South Alley \ —__ , r liii . ,, ,1 :, • 1.. . .1 a'. `' _ PraPosetl Locallon a}New Unit :'., / --.. ---_ -.—_ t moi. l t. _ West Face -V _ r- I `x II ____i .. �.-{__ - SUBMITTAL DATA: MXZ-5C42NA2 MITSUBISHI M-SERIES MULTI-INDOOR INVERTER HEAT PUMP SYSTEM M ELECTRIC Job Name: System Reference: Date: p 1 A ��allllllllllllllllllllluul�� .411111111111111111111111111111111111111111111, a ,IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIV i� illllllllllllllllllllllllllllllllllllllllllllll!�' �� '1111llll�iiiiiiiiiiimiiolllllpDl 1t 11. Outdoor Unit:MXZ-5C42NA2 ACCESSORIES ❑ 3/8"x 1/2"Port Adapter(MAC-A454JP-E) ❑ 1/2"x 3/8"Port Adapter(MAC-A455JP-E) ❑ 1/2"x 5/8"Port Adapter(MAC-A456JP-E) ❑ 1/4"x 3/8"Port Adapter(PAC-493PI) ❑ 3/8"x 5/8"Port Adapter(PAC-SG76RJ-E) ❑ M-NETAdapter(PAC-IFO1 MNT-E) ❑ Base Heater(PAC-645BH-E) (For data on specific indoor units,see the MXZ-C Technical and Service Manual.) Specifications Model Name Unit Type MXZ-5C42NA2 Rated Capacity Btu/h 40,500/37,400 Cooling* Capacity Range Btu/h 6,000-43,000 (Non-ducted/Ducted) Rated Total Input W 4,403/4,112 Rated Capacity Btu/h 45,000/41,000 Heating at 47°F* Capacity Range Btu/h 7,200-53,600 (Non-ducted/Ducted) Rated Total Input W 3,575/3,463 Heating at 17°F* Rated Capacity Btu/h 24,400/23,000 (Non-ducted/Ducted) Rated Total Input W 2,943/2,869 Power Supply Voltage,Phase,Hertz 208/230V, 1-Phase,60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 40 MCA A 32.5 Voltage Indoor-Outdoor S1-S2 V AC 208/230 Indoor-Outdoor S2-S3 V DC±24 Compressor INVERTER-driven Scroll Hermetic Fan Motor(ECM) F.L.A. 2.43 Cooling 56 Sound Pressure Level Heating dB(A) 58 External Dimensions(H x W x D) In(mm) 41-9/32 x 37-13/32 x 13 (1048 x 950 x 330) Net Weight Lbs(kg) 189(86) External Finish Munsell No.3Y 7.8/11 Refrigerant Pipe Size O.D.— Liquid(High Pressure) In(mm) 1/4(6.35) Eight Ports Gas(Low Pressure) A:1/2(12.7); B,C,D,E: 3/8(9.52) Max.Refrigerant Line Length Ft(m) 262(80) Max.Piping Length for Each Indoor Unit Ft(m) 82(25) Max.Refrigerant Pipe Height If IDU is Above ODU Ft m 49(15) Difference If IDU is Below ODU ( ) 49(15) Connection Method Flared/Flared Refrigerant R410A *Rating Conditions per AHRI Standard: Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB Heating at 47°F I Indoor:70°F(21°C)DB/60°F(16°C)WB Heating at 17°F I Indoor:70°F(21°C)DB Cooling I Outdoor:95°F(35°C)DB/23.9°C(75°F)WB Heating at 47°F I Outdoor:47°F(8°C)DB/43°F(6°C)WB Heating at 17°F I Outdoor:17°F(-8°C)DB/15°F(-9°C)WB Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. SPECIFICATIONS : MXZ-5C42NA2, contd. OPERATING RANGE: ENERGY EFFICIENCIES: Outdoor Indoor Unit Type SEER EER HSPF COP @ COP @ 47 F 17°F Cooling 14 to 115° F(-10 to 46°C) DB Non-ducted 19.7 9.2 10.30 3.69 2.43 Heating 5to 65°F(-15 to 18°C)WB (06+09+09+09+09) Ducted and 17.5 9.1 9.70 3.58 2.39 Non-ducted Ducted 15.2 9.0 9.10 3.47 2.35 (09+09+09+09+09) NOTES: • Minimum of two Indoor Units must be connected to the MXZ-5C42NA2. • Minimum installed capacity cannot be less than 12,000 Btu/h. • Total connected capacity must not exceed 130%of outdoor unit capacity. • System can operate with only one Indoor Unit turned on. • Information provided at 208/230V. • For Reference: -MXZ-C Technical&Service Manual for detailed specifications and additional information per Indoor Unit Combination. -MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. MVZ CONNECTION RULES: • Only 1 MVZ may be used on any system. • When an MVZ is connected,total connected capacity must be 100%or less. • When an MVZ is connected,no P-Series indoor units can be used(PCA, PLA,or PEAD). Notes: Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. MXZ-5C42NA2 OPERATIONAL PERFORMANCE DUCTED: Operational Cooling Capacity Range(Btu/h) Performance for Indoor ' Heating Capacity Range(Btu/h) Power Usage Current Unit Combinations Range(W) (208/230V) (Unit A+Unit B+ Unit A Unit B Unit C Unit D Unit E Unit C+Unit D+Unit E) 9 9000 0 0 0 0 10900 0 0 0 0 12 12000 0 0 0 0 13600 0 0 0 0 15 15000 0 0 0 0 18000 0 0 0 0 18 17200 0 0 0 0 21600 0 0 0 0 24 24000 0 0 0 0 26000 0 0 0 0 9+g 9000 9000 0 0 0 10900 10900 0 0 0 9+ 12 9000 12000 0 0 0 10500 14000 0 0 0 9+ 15 9000 15000 0 0 0 10200 17000 0 0 0 9+ 18 8733 17467 0 0 0 9333 18667 0 0 0 9+24 7636 20364 0 0 0 7636 20364 0 0 0 12+ 12 12000 12000 0 0 0 13600 13600 0 0 0 12+ 15 11644 14556 0 0 0 12444 15556 0 0 0 12+ 18 11200 16800 0 0 0 11200 16800 0 0 0 12+24 9333 18667 0 0 0 9333 18667 0 0 0 15+ 15 14000 14000 0 0 0 14000 14000 0 0 0 TBD 15+ 18 12727 15273 0 0 0 12727 15273 0 0 0 15+24 11154 17846 0 0 0 11154 17846 0 0 0 18+ 18 14000 14000 0 0 0 14000 14000 0 0 0 18+24 12429 16571 0 0 0 12429 16571 0 0 0 24+24 15000 15000 0 0 0 15000 15000 0 0 0 g+g+g 9000 9000 9000 0 0 10900 10900 10900 0 0 9+9+ 12 9000 9000 12000 0 0 9810 9810 13080 0 0 9+9+ 15 8727 8727 14545 0 0 8918 8918 14864 0 0 g+g+ 18 8000 8000 16000 0 0 8175 8175 16350 0 0 9+9+24 6857 6857 18286 0 0 7007 7007 18686 0 0 9+ 12+ 12 8727 11636 11636 0 0 8918 11891 11891 0 0 9+ 12+ 15 8000 10667 13333 0 0 8175 10900 13625 0 0 9+ 12+ 18 7385 9846 14769 0 0 7546 10062 15092 0 0 9+ 12+24 6400 8533 17067 0 0 6540 8720 17440 0 0 9+ 15+ 15 7385 12308 12308 0 0 I 7546 I 12577 I 12577 I 0 I 0 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. MXZ-5C42NA2 OPERATIONAL PERFORMANCE, contd. DUCTED: Operational Cooling Capacity Range(Btu/h) Performance for Indoor i Heating Capacity Range(Btu/h) Power Usage Current Unit Combinations Range(W) (208/230V) (Unit A+Unit B+ Unit A Unit B Unit C Unit D Unit E Unit C+Unit D+Unit E) 9+ 15+ 18 6857 11429 13714 0 0 7007 11679 14014 0 0 9+ 15+24 6000 10000 16000 0 0 6131 10219 16350 0 0 9+ 18+ 18 6400 12800 12800 0 0 6540 13080 13080 0 0 9+ 18+24 5647 11294 15059 0 0 5771 11541 15388 0 0 12+ 12+ 12 10667 10667 10667 0 0 10900 10900 10900 0 0 12+ 12+ 15 9846 9846 12308 0 0 10062 10062 12577 0 0 12+ 12+ 18 9143 9143 13714 0 0 9343 9343 14014 0 0 12+ 12+24 8000 8000 16000 0 0 8175 8175 16350 0 0 12+ 15+ 15 9143 11429 11429 0 0 9343 11679 11679 0 0 12+ 15+ 18 8533 10667 12800 0 0 8720 10900 13080 0 0 12+ 15+24 7529 9412 15059 0 0 7694 9618 15388 0 0 12+ 18+ 18 8000 12000 12000 0 0 8175 12263 12263 0 0 15+ 15+ 15 10667 10667 10667 0 0 10900 10900 10900 0 0 15+ 15+ 18 10000 10000 12000 0 0 10219 10219 12263 0 0 15+ 18+ 18 9412 11294 11294 0 0 9618 11541 11541 0 0 TBD g+g+g+g 8600 8600 8600 8600 0 8600 8600 8600 8600 0 9+9+9+ 12 8031 8031 8031 10708 0 8031 8031 8031 10708 0 9+9+9+ 15 7671 7671 7671 12786 0 7671 7671 7671 12786 0 g+g+g+ 18 7160 7160 7160 14320 0 7160 7160 7160 14320 0 9+9+9+24 6565 6565 6565 17506 0 6565 6565 6565 17506 0 9+9+ 12+ 12 7671 7671 10229 10229 0 7671 7671 10229 10229 0 9+9+ 12+ 15 7160 7160 9547 11933 0 7160 7160 9547 11933 0 9+9+ 12+ 18 6975 6975 9300 13950 0 6975 6975 9300 13950 0 9+9+ 15+ 15 6975 6975 11625 11625 0 6975 6975 11625 11625 0 9+9+ 15+ 18 6565 6565 10941 13129 0 6565 6565 10941 13129 0 9+ 12+ 12+ 12 7160 9547 9547 9547 0 7160 9547 9547 9547 0 9+ 12+ 12+ 15 6975 9300 9300 11625 0 6975 9300 9300 11625 0 9+ 12+ 12+ 18 6565 8753 8753 13129 0 6565 8753 8753 13129 0 9+ 12+ 15+ 15 6565 8753 10941 10941 0 6565 8753 10941 10941 0 12+ 12+ 12+ 12 9300 9300 9300 9300 0 I 9300 I 9300 I 9300 I 9300 I 0 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. MXZ-5C42NA2 OPERATIONAL PERFORMANCE, contd. DUCTED: Operational Cooling Capacity Range(Btu/h) Performance for Indoor i Heating Capacity Range(Btu/h) Power Usage Current Unit Combinations Range(W) (208/230V) (Unit A+Unit B+ Unit A Unit B Unit C Unit D Unit E Unit C+Unit D+Unit E) 12+ 12+ 12+ 15 8753 8753 8753 10941 0 8753 8753 8753 10941 0 g+g+g+g+g 7500 7500 7500 7500 7500 8200 8200 8200 8200 8200 9+9+9+9+ 12 7312 7312 7312 7312 9750 7875 7875 7875 7875 10500 9+9+9+9+ 15 7059 7059 7059 7059 11765 7588 7588 7588 7588 12647 TBD 9+9+9+9+ 18 6667 6667 6667 6667 13333 7333 7333 7333 7333 14667 9+9+9+ 12+ 12 7059 7059 7059 9412 9412 7588 7588 7588 10118 10118 9+9+9+ 12+ 15 6667 6667 6667 8889 11111 7333 7333 7333 9778 12222 9+9+ 12+ 12+ 12 6667 6667 8889 8889 8889 7333 7333 9778 9778 9778 NON-DUCTED: Operational Cooling Capacity Range(Btu/h) Performance for Indoor Heating Capacity Range(Btu/h) Power Usage Current Unit Combinations Range(W) (208/230V) (Unit A+Unit B+ Unit A Unit B Unit C Unit D Unit E Unit C+Unit D+Unit E) 6 6000 0 0 0 0 7400 0 0 0 0 9 9000 0 0 0 0 11000 0 0 0 0 12 12000 0 0 0 0 14400 0 0 0 0 15 14000 0 0 0 0 18000 0 0 0 0 18 17200 0 0 0 0 21600 0 0 0 0 24 22500 0 0 0 0 27600 0 0 0 0 6+6 6000 6000 0 0 0 7400 7400 0 0 0 6+g 6000 9000 0 0 0 7360 11040 0 0 0 6+ 12 6000 12000 0 0 0 7333 14667 0 0 0 TBD 6+ 15 5714 14286 0 0 0 7257 18143 0 0 0 6+ 18 5750 17250 0 0 0 7000 21000 0 0 0 6+24 5600 22400 0 0 0 5600 22400 0 0 0 9+g 9000 9000 0 0 0 11000 11000 0 0 0 9+ 12 8571 11429 0 0 0 10886 14514 0 0 0 9+ 15 8625 14375 0 0 0 10500 17500 0 0 0 9+ 18 8600 17200 0 0 0 9333 18667 0 0 0 9+24 7636 20364 0 0 0 7636 20364 0 0 0 12+ 12 11500 11500 0 0 0 14000 14000 0 0 0 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. MXZ-5C42NA2 OPERATIONAL PERFORMANCE, contd. NON-DUCTED: Operational Cooling Capacity Range(Btu/h) Performance for Indoor Mi. Heating Capacity Range(Btu/h) Power Usage Current Unit Combinations Range(W) (208/230V) (Unit A+Unit B+ Unit A Unit B Unit C Unit D Unit E Unit C+Unit D+Unit E) 12+ 15 11467 14333 0 0 0 12444 15556 0 0 0 12+ 18 11200 16800 0 0 0 11200 16800 0 0 0 12+24 9333 18667 0 0 0 9333 18667 0 0 0 15+ 15 14000 14000 0 0 0 14000 14000 0 0 0 15+ 18 12727 15273 0 0 0 12727 15273 0 0 0 15+24 11154 17846 0 0 0 11154 17846 0 0 0 18+ 18 14000 14000 0 0 0 14000 14000 0 0 0 18+24 12429 16571 0 0 0 12429 16571 0 0 0 24+24 15000 15000 0 0 0 15000 15000 0 0 0 6+6+6 6000 6000 6000 0 0 7400 7400 7400 0 0 6+6+g 6000 6000 9000 0 0 7657 7657 11486 0 0 6+6+ 12 6000 6000 12000 0 0 7300 7300 14600 0 0 6+6+ 15 5778 5778 14444 0 0 7289 7289 18222 0 0 6+6+ 18 5800 5800 17400 0 0 6560 6560 19680 0 0 6+6+24 5433 5433 21733 0 0 5467 5467 21867 0 0 TBD 6+g+g 6000 9000 9000 0 0 7300 10950 10950 0 0 6+9+ 12 5778 8667 11556 0 0 7289 10933 14578 0 0 6+9+ 15 5800 8700 14500 0 0 6560 9840 16400 0 0 6+9+ 18 5818 8727 17455 0 0 5964 8945 17891 0 0 6+9+24 5015 7523 20062 0 0 5046 7569 20185 0 0 6+ 12+ 12 5800 11600 11600 0 0 6560 13120 13120 0 0 6+ 12+ 15 5818 11636 14545 0 0 5964 11927 14909 0 0 6+ 12+ 18 5433 10867 16300 0 0 5467 10933 16400 0 0 6+ 12+24 4657 9314 18629 0 0 4686 9371 18743 0 0 6+ 15+ 15 5433 13583 13583 0 0 5467 13667 13667 0 0 6+ 15+ 18 5015 12538 15046 0 0 5046 12615 15138 0 0 6+ 15+24 4347 10867 17387 0 0 4373 10933 17493 0 0 6+ 18+ 18 4657 13971 13971 0 0 4686 14057 14057 0 0 6+ 18+24 4075 12225 16300 0 0 4100 12300 16400 0 0 g+g+g 8667 8667 8667 0 0 I 10933 I 10933 I 10933 I 0 I 0 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. MXZ-5C42NA2 OPERATIONAL PERFORMANCE, contd. NON-DUCTED: Operational Cooling Capacity Range(Btu/h) Performance for Indoor Mi. Heating Capacity Range(Btu/h) Power Usage Current Unit Combinations Range(W) (208/230V) (Unit A+Unit B+ Unit A Unit B Unit C Unit D Unit E Unit C+Unit D+Unit E) 9+9+ 12 8700 8700 11600 0 0 9840 9840 13120 0 0 9+9+ 15 8727 8727 14545 0 0 8945 8945 14909 0 0 g+g+ 18 8150 8150 16300 0 0 8200 8200 16400 0 0 9+9+24 6986 6986 18629 0 0 7029 7029 18743 0 0 9+ 12+ 12 8727 11636 11636 0 0 8945 11927 11927 0 0 9+ 12+ 15 8150 10867 13583 0 0 8200 10933 13667 0 0 9+ 12+ 18 7523 10031 15046 0 0 7569 10092 15138 0 0 9+ 12+24 6520 8693 17387 0 0 6560 8747 17493 0 0 9+ 15+ 15 7523 12538 12538 0 0 7569 12615 12615 0 0 9+ 15+ 18 6986 11643 13971 0 0 7029 11714 14057 0 0 9+ 15+24 6113 10188 16300 0 0 6150 10250 16400 0 0 9+ 18+ 18 6520 13040 13040 0 0 6560 13120 13120 0 0 9+ 18+24 5753 11506 15341 0 0 5788 11576 15435 0 0 12+ 12+ 12 10867 10867 10867 0 0 10933 10933 10933 0 0 12+ 12+ 15 10031 10031 12538 0 0 10092 10092 12615 0 0 TBD 12+ 12+ 18 9314 9314 13971 0 0 9371 9371 14057 0 0 12+ 12+24 8150 8150 16300 0 0 8200 8200 16400 0 0 12+ 15+ 15 9314 11643 11643 0 0 9371 11714 11714 0 0 12+ 15+ 18 8693 10867 13040 0 0 8747 10933 13120 0 0 12+ 15+24 7671 9588 15341 0 0 7718 9647 15435 0 0 12+ 18+ 18 8150 12225 12225 0 0 8200 12300 12300 0 0 15+ 15+ 15 10867 10867 10867 0 0 10933 10933 10933 0 0 15+ 15+ 18 10188 10188 12225 0 0 10250 10250 12300 0 0 15+ 18+ 18 9588 11506 11506 0 0 9647 11576 11576 0 0 6+6+6+6 6000 6000 6000 6000 0 7400 7400 7400 7400 0 6+6+6+9 6000 6000 6000 9000 0 7378 7378 7378 11067 0 6+6+6+ 12 6000 6000 6000 12000 0 7200 7200 7200 14400 0 6+6+6+ 15 5818 5818 5818 14545 0 6545 6545 6545 16364 0 6+6+6+ 18 5900 5900 5900 17700 0 6000 6000 6000 18000 0 6+6+6+24 5429 5429 5429 21714 0 I 5429 I 5429 I 5429 I 21714 I 0 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. MXZ-5C42NA2 OPERATIONAL PERFORMANCE, contd. NON-DUCTED: Operational Cooling Capacity Range(Btu/h) Performance for Indoor Mi. Heating Capacity Range(Btu/h) Power Usage Current Unit Combinations Range(W) (208/230V) (Unit A+Unit B+ Unit A Unit B Unit C Unit D Unit E Unit C+Unit D+Unit E) 6+6+9+9 6000 6000 9000 9000 0 7200 7200 10800 10800 0 6+6+9+ 12 5818 5818 8727 11636 0 6545 6545 9818 13091 0 6+6+9+ 15 5900 5900 8850 14750 0 6000 6000 9000 15000 0 6+6+9+ 18 5846 5846 8769 17538 0 5846 5846 8769 17538 0 6+6+9+24 5067 5067 7600 20267 0 5067 5067 7600 20267 0 6+6+ 12+ 12 5900 5900 11800 11800 0 6000 6000 12000 12000 0 6+6+ 12+ 15 5846 5846 11692 14615 0 5846 5846 11692 14615 0 6+6+ 12+ 18 5429 5429 10857 16286 0 5429 5429 10857 16286 0 6+6+ 12+24 4750 4750 9500 19000 0 4750 4750 9500 19000 0 6+6+ 15+ 15 5429 5429 13571 13571 0 5429 5429 13571 13571 0 6+6+ 15+ 18 5067 5067 12667 15200 0 5067 5067 12667 15200 0 6+6+ 15+24 4471 4471 11176 17882 0 4471 4471 11176 17882 0 6+6+ 18+ 18 4750 4750 14250 14250 0 4750 4750 14250 14250 0 6+g+g+g 5818 8727 8727 8727 0 6545 9818 9818 9818 0 6+9+9+ 12 5900 8850 8850 11800 0 6000 9000 9000 12000 0 TBD 6+9+9+ 15 5846 8769 8769 14615 0 5846 8769 8769 14615 0 6+g+g+ 18 5429 8143 8143 16286 0 5429 8143 8143 16286 0 6+9+9+24 4750 7125 7125 19000 0 4750 7125 7125 19000 0 6+9+ 12+ 12 5846 8769 11692 11692 0 5846 8769 11692 11692 0 6+9+ 12+ 15 5429 8143 10857 13571 0 5429 8143 10857 13571 0 6+9+ 12+ 18 5067 7600 10133 15200 0 5067 7600 10133 15200 0 6+9+ 12+24 4471 6706 8941 17882 0 4471 6706 8941 17882 0 6+9+ 15+ 15 5067 7600 12667 12667 0 5067 7600 12667 12667 0 6+9+ 15+ 18 4750 7125 11875 14250 0 4750 7125 11875 14250 0 6+9+ 18+ 18 4471 6706 13412 13412 0 4471 6706 13412 13412 0 6+ 12+ 12+ 12 5429 10857 10857 10857 0 5429 10857 10857 10857 0 6+ 12+ 12+ 15 5067 10133 10133 12667 0 5067 10133 10133 12667 0 6+ 12+ 12+ 18 4750 9500 9500 14250 0 4750 9500 9500 14250 0 6+ 12+ 15+ 15 4750 9500 11875 11875 0 4750 9500 11875 11875 0 6+ 12+ 15+ 18 4471 8941 11176 13412 0 I 4471 I 8941 I 11176 I 13412 I 0 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. MXZ-5C42NA2 OPERATIONAL PERFORMANCE, contd. NON-DUCTED: Operational Cooling Capacity Range(Btu/h) Performance for Indoor i Heating Capacity Range(Btu/h) ' Power Usage Current Unit Combinations Range(W) (208/230V) (Unit A+Unit B+ Unit A Unit B Unit C Unit D Unit E Unit C+Unit D+Unit E) 6+ 15+ 15+ 15 4471 11176 11176 11176 0 4471 11176 11176 11176 0 g+g+g+g 8850 8850 8850 8850 0 9000 9000 9000 9000 0 9+9+9+ 12 8769 8769 8769 11692 0 8769 8769 8769 11692 0 9+9+9+ 15 8143 8143 8143 13571 0 8143 8143 8143 13571 0 g+g+g+ 18 7600 7600 7600 15200 0 7600 7600 7600 15200 0 9+9+9+24 6706 6706 6706 17882 0 6706 6706 6706 17882 0 9+9+ 12+ 12 8143 8143 10857 10857 0 8143 8143 10857 10857 0 9+9+ 12+ 15 7600 7600 10133 12667 0 7600 7600 10133 12667 0 9+9+ 12+ 18 7125 7125 9500 14250 0 7125 7125 9500 14250 0 9+9+ 15+ 15 7125 7125 11875 11875 0 7125 7125 11875 11875 0 9+9+ 15+ 18 6706 6706 11176 13412 0 6706 6706 11176 13412 0 9+ 12+ 12+ 12 7600 10133 10133 10133 0 7600 10133 10133 10133 0 9+ 12+ 12+ 15 7125 9500 9500 11875 0 7125 9500 9500 11875 0 9+ 12+ 12+ 18 6706 8941 8941 13412 0 6706 8941 8941 13412 0 9+ 12+ 15+ 15 6706 8941 11176 11176 0 6706 8941 11176 11176 0 TBD 12+ 12+ 12+ 12 9500 9500 9500 9500 0 9500 9500 9500 9500 0 12+ 12+ 12+ 15 8941 8941 8941 11176 0 8941 8941 8941 11176 0 6+6+6+6+6 6000 6000 6000 6000 6000 7400 7400 7400 7400 7400 6+6+6+6+9 6000 6000 6000 6000 9000 7382 7382 7382 7382 11073 6+6+6+6+ 12 6000 6000 6000 6000 12000 7333 7333 7333 7333 14667 6+6+6+6+ 15 5846 5846 5846 5846 14615 6862 6862 6862 6862 17154 6+6+6+6+ 18 5786 5786 5786 5786 17357 6429 6429 6429 6429 19286 6+6+6+6+24 5200 5200 5200 5200 20800 5725 5725 5725 5725 22900 6+6+6+g+g 6000 6000 6000 9000 9000 7333 7333 7333 11000 11000 6+6+6+9+ 12 5846 5846 5846 8769 11692 6862 6862 6862 10292 13723 6+6+6+9+ 15 5786 5786 5786 8679 14464 6429 6429 6429 9643 16071 6+6+6+9+ 18 5547 5547 5547 8320 16640 6107 6107 6107 9160 18320 6+6+6+9+24 4894 4894 4894 7341 19576 5459 5459 5459 8188 21835 6+6+6+ 12+ 12 5786 5786 5786 11571 11571 6429 6429 6429 12857 12857 6+6+6+ 12+ 15 5547 5547 5547 11093 13867 I 6107 I 6107 I 6107 I 12213 I 15267 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. MXZ-5C42NA2 OPERATIONAL PERFORMANCE, contd. NON-DUCTED: Operational Cooling Capacity Range(Btu/h) Performance for Indoor i Heating Capacity Range(Btu/h) Power Usage Current Unit Combinations Range(W) (208/230V) (Unit A+Unit B+ Unit A Unit B Unit C Unit D Unit E Unit C+Unit D+Unit E) 6+6+6+ 12+ 18 5200 5200 5200 10400 15600 5725 5725 5725 11450 17175 6+6+6+ 12+24 4622 4622 4622 9244 18489 5156 5156 5156 10311 20622 6+6+6+ 15+ 15 5200 5200 5200 13000 13000 5725 5725 5725 14313 14313 6+6+6+ 15+ 18 4894 4894 4894 12235 14682 5459 5459 5459 13647 16376 6+6+6+ 18+ 18 4622 4622 4622 13867 13867 5156 5156 5156 15467 15467 6+6+g+g+g 5846 5846 8769 8769 8769 6862 6862 10292 10292 10292 6+6+9+9+ 12 5786 5786 8679 8679 11571 6429 6429 9643 9643 12857 6+6+9+9+ 15 5547 5547 8320 8320 13867 6107 6107 9160 9160 15267 6+6+9+9+ 18 5200 5200 7800 7800 15600 5725 5725 8588 8588 17175 6+6+9+9+24 4622 4622 6933 6933 18489 5156 5156 7733 7733 20622 6+6+9+ 12+ 12 5547 5547 8320 11093 11093 6107 6107 9160 12213 12213 6+6+9+ 12+ 15 5200 5200 7800 10400 13000 5725 5725 8588 11450 14313 6+6+9+ 12+ 18 4894 4894 7341 9788 14682 5459 5459 8188 10918 16376 6+6+9+ 15+ 15 4894 4894 7341 12235 12235 5459 5459 8188 13647 13647 6+6+9+ 15+ 18 4622 4622 6933 11556 13867 5156 5156 7733 12889 15467 TBD 6+6+ 12+ 12+ 12 5200 5200 10400 10400 10400 5725 5725 11450 11450 11450 6+6+ 12+ 12+ 15 4894 4894 9788 9788 12235 5459 5459 10918 10918 13647 6+6+ 12+ 12+ 18 4622 4622 9244 9244 13867 5156 5156 10311 10311 15467 6+6+ 12+ 15+ 15 4622 4622 9244 11556 11556 5156 5156 10311 12889 12889 6+g+g+g+g 5786 8679 8679 8679 8679 6429 9643 9643 9643 9643 6+9+9+9+ 12 5547 8320 8320 8320 11093 6107 9160 9160 9160 12213 6+9+9+9+ 15 5200 7800 7800 7800 13000 5725 8588 8588 8588 14313 6+9+9+9+ 18 4894 7341 7341 7341 14682 5459 8188 8188 8188 16376 6+9+9+ 12+ 12 5200 7800 7800 10400 10400 5725 8588 8588 11450 11450 6+9+9+ 12+ 15 4894 7341 7341 9788 12235 5459 8188 8188 10918 13647 6+9+9+ 12+ 18 4622 6933 6933 9244 13867 5156 7733 7733 10311 15467 6+9+9+ 15+ 15 4622 6933 6933 11556 11556 5156 7733 7733 12889 12889 6+9+ 12+ 12+ 12 4894 7341 9788 9788 9788 5459 8188 10918 10918 10918 6+9+ 12+ 12+ 15 4622 6933 9244 9244 11556 5156 7733 10311 10311 12889 6+ 12+ 12+ 12+ 12 4622 9244 9244 9244 9244 I 5156 I 10311 I 10311 I 10311 I 10311 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. MXZ-5C42NA2 OPERATIONAL PERFORMANCE, contd. NON-DUCTED: Operational Cooling Capacity Range(Btu/h) Performance for Indoor Heating Capacity Range(Btu/h) Power Usage Current Unit Combinations Range(W) (208/230V) (Unit A+Unit B+ Unit A Unit B Unit C Unit D Unit E Unit C+Unit D+Unit E) g+g+g+g+g 8320 8320 8320 8320 8320 9160 9160 9160 9160 9160 9+9+9+9+ 12 7800 7800 7800 7800 10400 8588 8588 8588 8588 11450 9+9+9+9+ 15 7341 7341 7341 7341 12235 8188 8188 8188 8188 13647 6933 6933 6933 6933 13867 g+g+g+g+ 18 TBD 7733 7733 7733 7733 15467 9+9+9+ 12+ 12 7341 7341 7341 9788 9788 8188 8188 8188 10918 10918 9+9+9+ 12+ 15 6933 6933 6933 9244 11556 7733 7733 7733 10311 12889 9+9+ 12+ 12+ 12 6933 6933 9244 9244 9244 7733 7733 10311 10311 10311 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. DIMENSIONS: MXZ-5C42NA2 I Unit: inch (mm) 6-7/8' 23-5/8' 6-7/8' Rear Air ntake 2-13/16' . 27/32' 4-19 2-1/32• 2-U Shaped Notched Hole 3-13 16' (Foundation Balt M101 13/32' I 31/8'� _ Iii— '-- �1 Side Air Intake* 11. �I 11 ii; ie I `I _ I m �I rn m 6-e1-5/16'Drain Hole 1• 13/32' n 113/32" e1_3/32'punched hole b0lscharge (Connecting wire hale) 2-(15/32'x1-13/32')Oval Hole 2-m7/8'punchetl hole (Foundation Bolt M10) 2-15/16' (Connectin. wire hole) 2-3/32'w 1-5/32'II 3-87/8'punchetl hole 37-13/32' 31/32' 13' 19/32' (Connecling wire hole) Iii Jill I,II_ . • r ®. • 'An' �. I I® .. Handle Imr:Opij ( l® / � Air intake Handl rigHantlle -.9 Hantlle I X ( �l �� `nI 6 +' -_-t. I .. 1 1 t , II II . ..Iri 2-3/4' If77. t.' ( ® ' ,t I I4m1 LIO ll n r y- v _° alUnit E ` ® N �i�l� GAS Unit D LID 1/4'b6.351FLARE ® !�I� LIO Unit C GA53/8'(99.521FLARE m m ( ® - GA51' _ � ( ® hll � G�S}Unit B � ( ® " _ ,1417..m, lli LID }unit A-' 1/4'(a6.35)FLARE IME� I t 1 GAS GA51/2'812.71FLARE of .a. I1-5/16' 14-7/32' J ui 1.FREE SPACE Conduit plate Top E O E E 3-15/16' or more et:To, cn r'r :.____Tit ll 6 Ofikell, I ' (11111 3-15/16' or more 3-25/32' or more � I'/ 41."'"' ('1( 2.SERVICE SPACE E E Oar. �� ( ``C SP 1 m c Lock nut Conduit connector �� Conduit plate Under 3-15/16' or more 'ar.�._ II SERVICE SPACE 13-25/32' or mare 13-25/32' or more mtMITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com ti.1:21 CERTIFIED. C E 1 I us ngary SmallHPAHard 21A1243 ca FORM#MXZ-5C42NA2 for Multiple Indoor Unit Styles-201605 °a .•..,-... •..•.....,.. Intertek Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc.