Loading...
HomeMy WebLinkAbout20210867 246 West Ave Solar Plans PHOTOVOLTAIC SYSTEM Lorne, /SYSTEM SIZE: -\ 1 - m�2 .. saint niers NAMEPLATE: 27.52 KW DC/23.4 KW AC - _ cemetery S EQUIPMENT: ••�" a' $ 46`wAveIe(t• t.c'- d PV MODULES: (64)HAN WHA Q PEAK DUO L-G8.2 430W L Apartments �..• �• o�,� F J PV OPTIMIZER(S): (64)P485 SOLAREDGE POWER OPTIMIZER 24e. t. / Saratoga Springs INVERTER(S): (1)SOLAREDGE SE14.4K-US '� ne�ovear. rrory Nva vin s U AC (1)SOLAREDGE SE 9K-US - • 9 No.,. W COMPONENT(S): (1)100A FUSED AC DISCONNECT14',.. 1 246 West Ave,Saratoga Springs, u,z LU-ZQ •TYPE OF INTERCONNECTION: LINE SIDE TAP IN THE MSP NY 12866,United States Q 2 >d 0_W HWcp co SCOPE OF WORK: _ AVSaratoga >Z LU O co INSTALLATION OF A CODE COMPLIANT,UTILITY INTERACTIVE - PHOTOVOLTAIC ELECTRIC SYSTEM. J c O§ v Q> N 2017 NATIONAL ELECTRIC CODE AERIAL VIEW 43.068362,-73.801571 VICINITY MAP v z w z J J Z 2020 INTERNATIONAL FIRE CODE NANAK MANAGEMENT LLC:246 WEST AVE, SARATOGA SPRINGS, NY 12866, USA J 2020 RESIDENTIAL CODE OF NYS 1 CD 2020 BUILDING CODE OF NYS GENERAL NOTES. BOXES W N N W APPLICABLE CODE PER LOCAL AUTHORITY HAVING D OR STANDARDIZED. LBE DOR JUNCTION ED PV BOXES PER APPROPRIATE JURISDICTIONAL y > Z 1 DRAWINGS ARE DIAGRAMMATIC ONLY THE LOCATION AND ROUTING of RACEWAYS sHAL UNLESS OTH SE NOTE JURISDICTION CASE CONDITIONS WIRE EQUIPMENT DEVICES,OVER-CURRENT Ox M SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM AREY U PROTECTION,GROUNDING SYSTEMS,HC(ALL EQUIPMENT AND MATERIALS)RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIALS AND ETHE CONTRACTOR SHALL DE E ENERGIZED,UNGROUNDED O < 0 R Dox DISCONNECT D DURING SERVICE 0ER S REQUIRED BY THE STRICTEST CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO ENSURE COMPLETE 55 CIRCUITS SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION \ / LONGEVITYCOMPLIANCE%MTH ALL CODES AND TO ENSURE THE AND SAFETY OF THE OPERABLE SYSTEM. DEMCE 5 METAL CONDUIT AND ENCLOSURES SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE RUN RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY Ee o\ INSIDE A BUILDING 57 THE POINT OF ry 6 MODULES SHALL NOT BE PLACED OVER ANY CONNECTION COMPLIES BE INSTALLED n1 THE OPPOSITE END OF THE <0 N- APPLICABLE CODES DNTRACTDR3HALLCDMPLY THANYANDALLREQUIREMENT3GI NBYUTILITY PBREAKER MENTISSIZEDACCORDINGTO () - a Z RR(CU)CONDUCTORSSHALLBEUUSED CONDUCTORS SHALL BE FOUND INYOND THE SCOPE NEC ARTICLES 6IS 90 L STRANDED OR Z m Z PV1 COVER PAGE N14(0)(2),9017,6053690INCLUDING, 35(F),690 sae90R9cB)V)LIMEMENTS ITED AT 61 DISCONNECT SID WITH PROPERLY RATED CONNECTORS nDaCuNG SHALL BE ROUNDEDvA ENERGIZED RIDGE RAIL INTEGRATE O f,'- g MODULES 1,ALLNE FERENCESSHALLBE DIRECTLY INTERCHANGEABLE GEABLEW�THCECREFERENCE NCIPLEASESEEDATASHEEnoRWTHTINPLAT.DIRECTBURIALRATED oco Q J PV2 SITE PLAN STRUCTURAL NOTES LAY IN LUGS USING STAINLESS STEEL HARDWARE,STAR WASHERS AND THREAD 63 ALL EQUIPMENT SHALL BE GROUNDED,INCLUDING BONDING JUMPERS WHERE r ---, 11 MOUNTS ARE DIAGRAMMATIC AND EXACT LOCATION MAY CHANGE,BUT SHALL BE ACCURATELY SPACED NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF RAIL. DATA PV3 MOUNTING PLAN 12 MOUNTS SHALL BE STAGGERED WHEN NECESSARY TO EVENLY DISTRIBUTE 13.DO NOT SPLICE RAILS IN MIDDLE 50,OF SPAN BETWEEN TWO MOUNTS LonDAMomcsTRAFTERS. 06/26/2021) PV4 MOUNTING DETAILS ELECTRICAL NOTES (DESIGNED BY 1 ,OF NEW `, 14 ALL EQUIPMENT IS LISTED FOR USE PV5-5.1 ELECTRICAL DIAGRAMS 39 ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION SHALL BE NEW AND LISTED By .�P�awPS A N7rr OT OVD D J A RECOGNIZED ELECTRICAL TESTING LABORATORY 5 PV6 MARKING&LABELS ° * t • 1 STATETHE CONNECTED ELECTRIC,PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN — THAT SYSTEM AND SHALL REMAIN IN THAT UNTIL THE ELECTRcALPRODUCTION AND DISTRIBUTION /, m24 , N 'ATTACHMENTS NETWORK VOLTAGE HAS BEEN RESTORED 41 ALL PV ARRAYS COMPONENT SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION 42 ANY AC SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENTCALCULATED AT THAT '�j�'� -. MANUFACTURER'S SPECIFICATIONS AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL BE PROPERLY COMPONENT �O 691373 ,a* i AIDED TO INDICATE AT ALL CONTACTS OF THE DISCONNECT EQUIPMENTMIGHT BE GROUNDED ���FE9 SIOHP� 44 MnaTI EQUIPMENT ED ELPaoB voc RATED MINIMUM 7-9-2021 PV1 INDEX J `GENERAL NOTES ARRAY 1 ) l o TILT:20° LL w AZIMUTH:210° ,'"- ,n U J a U J � ARRAY SPECIFICATIONS) zw Q Et D Iprfro. � J W H(n CO UTILITY METER d U Q co ODO ° AC DISCONNECT FUSED co F Q LLI 0 �� INVERTER M co H} COMBINER PANEL Y N z MAIN SERVICE PANEL 0 1 8"V ENT I LAT I ON SETBACK Q (0 ' . z J'43'WIDE FIRE ACCESS PATHWAY J ® 3'x3'GROUND LADDER ACCESS POINT rLO CO N ,- �� 4011/1kolpr .4,4 LEGEND U) } 1 D 41k ._ A 44:6 I Or N U (W o; O J - U „ 4 ' '''"fiirorApilr UJ jo 1- D m � a V m <}zz _}OO ; DATA , 06/26/2021) Aik Irr (,,,s1.,,,,,, , °F "Eli.0-°' �0,5 A.,yZJp OVD -.-:-* ti J z" , f \._.* ; q091373 fav Af0FES510HP\. 7-9-2021 PV2 V J - EL 18"VENTILATION 3'WIDE FIRE ' E1_)J SETBACK ACCESS PATHWAY / 97'_3•• / U O a I a 0-D -.--TT1TTT'TTTTff1TTT :TT! F-Ln Z 0 a D 2 v in 0 ~z O a a ti---__.y- -r - -r--ti- r. z co T M a 22, ~ ---~ / In CO 9„ 1' W N N (n J Lu } Y Y Q SOLAR MODULE I y 0121 D Q 0 19'_4 "-I 14'_1" 18'-9" -I pFNEW O JJ Qo} - Pcp,P5 A.NITJp MP1 Va a Q TILT:20° 1- AZIMUTH:210° >•y`�4 ONO W Z m �� O913. �,�E DATA P ����9-2021 06/26/2021-) DESIGNED BY: 1 OVD J TYPE DESCRIPTION QUANTITY TYPE DESCRIPTION QUANTITY ROOF SPECIFICATION 1 MODULE HANWHAQ PEAK DUO L-G8.2 430W 64 DISCONNECT 100A FUSED AC DISCONNECT 1 ROOF MATERIAL ASPHALT SHINGLE J ,--- DC DC OPTIMIZER P485 SOLAREDGE POWER OPTIMIZER 64 RAFTERS MP1 2"X 4"@ 24"O.C. SOLAREDGE SE14.4K-US 1 ROOF CONDITION GOOD PV3 INVERTER SOLAREDGE SE 9K-US 1 Technical Report for Everest Racking System SFRISTY� 0 Jun 26,2021 4 Array Layout V J a . .Nmna Lemro 99. tram .ewwehm Mem 27 a CrossRail Flush to Roof "" °° °' '°'°I" 162 psi o1 , ,, Portrait „mom 30.,61,, 2.6,pa, Name NANAK MANAGEMENT LLC n1 , e, to 65 portrait 10418,s 30.71lin 2.66:, U 6.10. !Os 25.46 lin Address Saratoga Springs,12866,NY ^�ea6 1 ,o e+o tabs 00005 eoe3lm torn 5 ' 0 10 23: H d .J Z Contact Phone 1 e ato 27,5 Portrait 091.,0 im 24.56 lbs z : 1 z >E P,eaa , 4 610 ,a0' Portrait 26,.a9.m 20.96 Hoz z W g Q d Flush Mounting system for tilted roofs contact Email , s 6,0' IT s.s Portrait 30s.49.b: 25.46 lbs 2 of 0 UJ CO W c malishrikantl998@gmailcom Tow 3.9oa.03lm 27.,0 lbs 2.66:, Z Q w 0 Fz (0> z2vQZ N Module Information 2 z co Name HanwhaQ CELLS-L-G82(430W) Z Dexriptlon 43001 Length 6'9.9" Peak Power 430.00Wp N V LO CO Width 3'4.6" Weight 54.00 lbs Estimated Bill of Materials W N N Lu Model Name Calc.Qty. Extra.Qty. Total.Qty. > Depth 0'1.4" (n > > D p4000662 CrossRall 48-X166".MIII 39 0 39 y Y U 00 End 0 < R 4000433 CrossRall EndCap,Black,CR 48-X,46X1 36 o 36 Configuration Parameters 9� 4000583 CrossRall3"Black Sleeve 46%,46X1 36 0 36 �o (V Code:ASCE7-10 D0'cupanep303gorr 11 O J j 0 Wind speed:115 mph Hurricane Prone:No Sleeve F Snow Load:50psf Wind Exposure Category.B 4000622 Bumdy WEER Lug 10.3 3 0 9 0 o !- Building Height:up to 3317' Roof Slope:22deg Dmd,0i eon g d a'C' Z do F 3 m Z 4000624 WEER Lug 10.3 Hardware Only,CR,Rot 9 0 9 —j Q Dmdcal Bonding O 5 r65 4000367 EverFlash eComp Kit,Sliver 144 0 144 KU ° < —I Pressure Loads Pooutmmmmc r DATA 4000382 HeyClipSun Runner Cable Clip SS,SOW 64 0 64 06/26/2021 Pressure Zones Loads Wireag ntncc ry ` J 4000385 5,1000nn CR 48-0,4601 Strutt Set,Mill 26 0 26 r DESIGNED BY r Down BaCon Max.411owa,les: nttarnmen spacing ua..ulnwable cantilever force up. shear0.000:0: 0o 0bs 0.00lbs Model Nameneno set Cals.Qty. Extra.Qty. Total. K OVD mnet,Pnnren r son.irsorae - c00 lb: 0,0lin0.00150 �p F N p� r 1 :ena3P...ea - - - o.w,,. o.00Ix 0.00 150 P`O�Pz a.N7rrP 2met,� ,, . . 0.mm, 00015 .oma * �� ,1 r * 7, r zone..s...pe, 0.40, 000 m 0.00 lbs w d 1 5 Zone an.w. - 5 20 0.000.00Doom ',/Q 091373 PV4 POPES 5100\ " g9 7A2021 SOLAREDGE J 1 STRING OF SE14.4K-US 0- 13 13 MODULES INVERTER 1 W/OPTIMIZERS -D__i—r DC UNGROUNDEDJ '-)} _LL 200A r 0 ¢n 1 MAIN SERVICE 2 J 1 STRING OFPANEL i_ 0 13 MODULES P NI 125A AC 100A AC 100A AC 120/208V O w Z> VV/OPTIMIZERS COMBINER DISCONNECT DISCONNECT Q g Q d D PANELUNFUSED FUSED 0 w H CO 1 STRING OF ¢� 50A/2P- 90A/2P 90A/2P 200A QY LU a coJ l • 12 MODULES .—.—ll— U QO .- VV/OPTIMIZ •ERS ,r<Z40A/2P • � • I M� BOOA vQ , N V • /�� Q SOLAREDGE P P P DM w z co 1 STRING OF SE9K-US © 0 Z 13 MODULES INVERTER 2 VV/OPTIMIZERS r DC UNGROUNDED �-'`, 0 2 U) (0 ■ ■ I W N Lu 1 STRING OF 13 MODULES P NI Y 0 W/OPTIMIZERS ° UD Q 0 /� '8- 0J < - Q a ¢ = >- LICONDUCTORS AND CONDUIT ----, MODULES ----, ` INVERTER(S) ( OTHER EQUIPMENT . a J J (10)#10 PV WIRE<> (64)HANWHA Q PEAK DUO L-G8.2 430W SOLAREDGE SE14.4K-US J DATA J (1)#6 THHN GND MAX AC OUTPUT:40A 100A FUSED AC DISCONNECT 3/4"EMT SOLAREDGE SE9K-US 06/26/2021_2 WATTS STC:430W J DESIGNED By J MAX AC OUTPUT:25A <> (3)#6 THHN ISC:10.83A (1)#6 THHN GND INVERTER OCPD CALC:(25+40)X 1.25 O F N f yy OVD J 1"EMT IMP:10.31A =81.25 P ovps A,NZ O VOC:49.33V ", a' ,1 >T r (3)#4 THHN MIN OCPD:90A * * <> (1)#6THHN GND VMP:41.70V WIREAMPACITY:85A@75°CTERMINAL .'maa J 1.25"EMT TEMPERATURE CORRECTION FACTOR: 31°-35°C=0.96 ° t <> p 09137.1 F" (3)#4 THHN CORRECTED WIRE AMPACITY:81.6A 'fp, (1)#6THHN GND 7-9-2021 PV5 1.25"EMT J J i J J J J SOLAREDGE LLo 1 STRING OF SEI4.4 K-US 13 MODULES INVERTER 1 \ _) W/OPTIMIZERS E_T ='�oo oNoreooNOEo ' 200A r MAIN SERVICE 0 MI PANEL 2 CO M—M 7 125A AC 120/208V Q ° 1 STRING OF COMBINER 100A AC 100A AC 4'Z W Z< 13 MODULES r . E� PANEL DISCONNECT DISCONNECT O W Q E W VV/OPTIMIZERS FUSED FUSED 0_Z SOA2P 200A Q LU H W(c 1 STRING OF ■—■ 90A/2P 90A/3P 90A13: J Q W Q 12 MODULES '$' • �' U Z j O W/OPTIMIZERS �� • �•% F Q co H} 40A/2P ® • • 800A V N Q Z SOLAREDGE � lijU 1 STRING OF SE9K-US UM \ W< 13 MODULES INVERTER 2 VV/OPTIMIZERS ooUNGROUND GP �1 / — N V V 1 STRING OF .-. W N N (q 13 MODULES — — Lu W//OPTIMIZERS 1 M > Z >" ,Y 0 U � a Q // O J Ee < F-1 Q a ¢ = F m Z \ CONDUCTORS AND CONDUIT MODULES J INVERTER(S) J ,-- OTHER EQUIPMENT J UaJ \ J (10)#10 PV WIRE SOLAREDGE SE14.4K-US (64)HANWHA Q PEAK DUO L-G8.2 430W 100A FUSED AC DISCONNECT DATA • (1)#6 THHN GND MAX AC OUTPUT:40A 06/26/202,� 3/4"EMT WATTS STC:430W SOLAREDGE SE9K-US F NE),,,, DESIGNED BY 1 MAX AC OUTPUT:25A 0 (3)#6 THHN ISC:10.83A �� PSA. • (1)#6 THHN GND INVERTER OCPD CALC:(25+40)X 1.25 ,,,i. ,o,' �zr y OVD 1"EMT IMP:10.31A =81.25 * r� 1 iei * VOC:49.33V -, r 1 (3)#4 THHN MIN OCPD:90A w o v2a • (1)#6 THHN GND VMP:41.70V WIRE AMPACITY:85A @75°C TERMINAL y i 2 1.25"EMT TEMPERATURE CORRECTION FACTOR: 0.9 J 31°-35°C=0.96 Op 1313 `�0 (3)#4 THHN CORRECTED WIRE AMPACITY:81.6A �OFES SIONP • (1)#6 THHN GND 7-9-2021 1.25"EMT PV5.1 \ J / \ / \ > INVERTER AC DISCONNECT MAIN SERVICE PANEL ,---4;)Li 0 NEC 690.17(4)UNGROUNDED SYSTEMS NEC 690.14(C)(2) NEC 705.12(D)(4) O. WARNING PHOTOVOLTAIC DISCONNECT WARNING of ELECTRIC SHOCK HAZARD. FOR UTILITY OPERATIONS THIS SERVICE ALSO SERVED U BY A PHOTOVOLTAIC SYSTEM THE DC CONDUCTORS OF THIS w_i W PHOTOVOLTAIC SYSTEM ARE NEC 690.54 —I H 0 NEC 705.12(D)(7) CO z W Z< UNGROUNDED AND MAY BEQ .0 >E w PHOTOVOLTAIC ARRAY —1 g <o-D ENERGIZED. AC DISCONNECT WARNING as w H-CO OPERATING CURRENT: 65 A INVERTER OUTPUT CONNECTION z Q w a7 co NEC 690.14)C))2) DO NOT RELOCATE THIS z !O OPERATING VOLTAGE: 208 V Y o } OVERCURRENT DEVICE a 2 v Q PHOTOVOLTAIC DISCONNECT a Y N FOR UTILITY OPERATIONS LABEL TO BE INSTALLED DIRECTLY NEXT TO PV BACKFEED z CONDUIT, RACEWAYS, BTH KR.IF NEAP PERMANENT EAR OW ANYWKER HERE RPONTINGOTO Z PV PHOTOVOLTAIC ENCLOSURES, CABLE NEC 690.54 W N N / SYSTEM EQUIPPED WITH ASSEMBLIES PHOTOVOLTAIC POWER SOURCE Lu y RAPID SHUTDOWN & JUNCTION BOXES OPERATING AC VOLTAGE: 208 V p Q 0 NEC ssosl(E)(3)CONDUIT MAXIMUM OPERATING AC OUTPUT CURRENT: 65 AMPS /a >_ '8- NEC 690.53 #INVERTER 1O J N Warning:Photovoltaic Power Source U o PHOTOVOLTAIC ARRAY NEC 690.14)C))2) ¢ a ¢ DC DISCONNECT NEC 690.35(F)UNGROUNDED SYSTEMS JUNCTION BOX u ° OPERATING CURRENT: 38 A PHOTOVOLTAIC DISCONNECT 1— DEE OPERATING VOLTAGE: 400.0 V WARNING FOR UTILITY OPERATIONS U n ELECTRIC SHOCK HAZARD. J MAX.SYSTEM VOLTAGE: 500.0 V THE DC CONDUCTORS OF THIS r DATA 1 SHORT-CIRCUIT CURRENT: 45.0 A PHOTOVOLTAIC SYSTEM ARE 06/26/2021) UNGROUNDED AND MAY BE oEs,NEoa ENERGIZED. NEC 690.53 #INVERTER2 OF NEW OVD J PHOTOVOLTAIC ARRAY ,,,,:\:„s A'NrTY y r 1 DC DISCONNECT ,* z A s OPERATING CURRENT: 26.5 A OPERATING VOLTAGE: 400.0 V . MAX.SYSTEM VOLTAGE: 600.0 V �T o 091371 SHORT-CIRCUIT CURRENT: 45.0 A pROFESSIOPV6 ]A2021 r�I