Loading...
HomeMy WebLinkAbout20210519 Caulfield Rooftop Solar Panels NOD 0 GA N`fi Tamie Ehinger, Chair CITY OF SARATOGA SPRINGS Leslie Mechem,Vice Chair {. 5 / Chris Bennett i DESIGN REVIEW COMMISSION Leslie DiCarlo � • Rob DuBoff 0 ,f • _ • Ellen Sheehan '`at CityHall -474 Broadway Sean Smith f(n Saratoga Springs, New York 12866 Steven Rowland,Alternate PORATED Tel:518-587-3550 x.25 17 Tad Roemer,Alternate www.saratoga-springs.org NOTICE OF DECISION In the matter of the application #20210519 Caulfield Rooftop Solar Panels 718 North Broadway Saratoga Springs, New York 12866 involving Historic Review of roof mounted solar panels within the Urban Residential-I District, tax parcel #165.36-2-1.I, within the City of Saratoga Springs. In accordance with 6 NYCRR Part 617,the Design Review Commission classifies this request as a SEQR: EC Type II action — exempt from further SEQR review And, in accordance with the objectives, standards and guidelines contained in the City Zoning Ordinance Article 240-7.4 Historic Review, the Design Review Commission issues the following decision on June 16, 2021: EC Approve as submitted or shown on the attached plans Note: this approval shall expire 18 months from the issuance date unless any necessary building permit has been issued and actual work begun. Record of vote: Record of vote: motion to approve made by T. Ehinger, seconded by E. Sheehan: passed 6-0 In favor: T. Ehinger, L. DiCarlo, R. DuBoff, L. Mechem, E. Sheehan, T. Roemer As a result of this decision, the applicant: EC may proceed with the proposed project as approved Please contact the Building Department to verify permit requirements. June 17, 2021 Chair Received by Accounts cc: Building Department File Accounts Dept. Applicant/Agent Page I of I w r- -,\ 06, 1 woo•apa1oyslse,m�.t I ESIL'EIE'HTS.d Z O m O~ rr Z p p ZQ ct B-- ,",,,-- 2.5;O Z w O m a¢W O, O U 0 1 I 1 LU VLl T 3LITi5 I'OA,5,Y0 Ld:ii`J opt >QyUOFUw�Nz O N W Q J LU ''d'Sa33N1,N3 NO153CI 3aOHS1S3M y W O W w w= z N z N W W z J o LU Z �wZ�a �w L'' W Z v W W= W U p = Q2 m _ =r/t4k N=_w pJU O =LL��p�LL�oW� c.' O _1- Q w = Z 2OaWpOwvaE2 Z w W ~ <.<0.0 H 0 (n /�/1 Lu ° a a LL sa�oN /(8 a}ea nab =9, U _ O Q - �,j D U H x b z < H 62 Q U ¢Z Z• = w 00 Alk II - ° w ©ty J ° z= 00 J Z O Q� w Z > ❑ z . g - �� � � m HiH O O� Q z=cvg , J .4 ❑ O L ....„ HH • O Q Com° Z ��; U �� Q UJ Q w❑(� z U (z) -<0�0 w0 '' Q °<711T-)0 w w0E- i- Qv'U�� wi-''an<'-w O w v) 0 J �mvw,c°�'QQ �w0C1' .,(0-1,,Z m �� w U m u_ 0- ❑T< Uz ZZ`o~U = ZQ°cnJ w QQ LU ❑ w w w1-O�OW =Q.-Zvy UQZ='LLUQ N Z, Q cn = CCI 1_ ° Q 0 a J Z J Q ❑Q C 1.07 JZJw0 U Q OU ¢❑ <700(3' o� QQ0 "'H > ❑ ' URJOU No��� 00m00=QUO O0 0 �� Z- Q� Q�w� �0Jw❑w�-❑� w� `n LL] w - wQ0 _10 �,Z�=I0 -1❑=Jt JW O-I Z m U0,0w O 0 V) Q NJ U< Q QIN 11,dV)0_N oz0 z U Q z U`�z —I Z O� N V30O Q H a Z C,_ ❑ >- 1_ U c, U O O LL] z v, v, ,LwIl OUz • U _ 000>1-- LL, <O'- w �❑ z Lu oow o 0 w w Q U U o 1- Q � Q. � _ ❑ . —w O ��� 11-1,,(..2Z `dal /- / ----- *NlDzLUAI zH _____ rl O Q Q H w 121 0 m 0HII I I I I _____ Npv, II II --1I II * C,N Q II II II II SII II ————— II II _____----- .1-:? II ii - I II � ' ce Z II I I I I ❑ w V)Z = II II ----- - U QAC' '- I Z CI LT] J ----- WI❑-0 z < ,LQ v0u_ -----, Z�'-U Q Z v, ---. C, H Qp ¢ °� J— z OUz< Q D� U � O OO�„ J ° z� N Ce Q N, Q O O 0 0 = 0 w,0 I- w --- 0��� z z w zQm W U A ❑ Q 1— 0 / .•I W o 1 ••11 I U •• e e Q 1 'i, ' I I 1— t Q ___I Q U ** 834/ F— - ,s � J T N Z �, y N I- 114 _ - ” � , o N zzJ o k+' Ro __� J0 °_U� o ,,k. 00 J � J�N Z ¢ u_, Qm b�0< Z J IYJ W ,,, ...;,,,,-„* S* LIC d/ m v+ .CT) vc 3 a) .—. C O F.,.2 N co W 05 U oho m -- a) cco ❑ N co, N Id 4N Z, U o o o ❑ v c IMI co C N L _c 'i N r C ai) , o .N L u) o '5 o (1) I 7, c 0 2 _ o U C O V O M co 5 V 0 F_ 'C N t in a N In N 03 L L 8 ..=. N O O N N — a N o N Et '_m N .0141111 0 1 El 0 s,,,„, [Jim°, s t ,, . . El _K � nes 407. i § Ei. = !%. . p - W O W r w w W w iv fil`` re Et Et Et w C7 N t9 C9 0 Ce ❑ d w w w w o IDis co co co cl . - . . . 13' ar Q r 7 sq a) o co 0- w L/f N r r r 0 .c 0-1 u) 4a 6 a4 0 cis ❑ a� V Z 2 2 2 2 y y O U) 2 H H H H 2 z [Vu) > > > > 00 EMEEZZ-C t u) o Ce LL a .w o O w N c3 v U O U ct N O N Et c p [s Z Z Z o w U ~ O W p L CC Z= U)LIJ pw Lt '� Q U)©0 N ,- O rn E © a v [D O a) W 6_ w� 2 0 aa) U o 7 C c v Et 00 co c c as O CJ co N o o D •.= itii IF N c c p L o "11/4 c� = c c C_ C co c ce o ❑ •• p a] F Q N N U a C w o V) a] w CO o +� 0 w > c� W o (6 Q c wCU4.. °J [n C c 'c _ V-} c., c., r D 0 0 o 0 0 >- Z o ii= 2, CD ami ❑ •'L 0 Lu co a CO'CDs CV c CD co Z - E z C ❑ 0 oo L . a 1- i U3 Q •41'.:1, :::','0.,1V-ii•O'il ,.,•; ' ' r ;r y Y- 'r ,y,, 11 _ ' . ' i' p z , , : � ';r,ft a � r •� Fay • -�iI0)_tii „a,.• ,p x} �'� vo �+4 { r - ilk C. • ',,!,J .+- tri II -- ( ''' ' -0 r. .. .1 II 1 4-71r (S `G i I 4•�'.d r {' l�rj t.r Fri rI,� J Ril rr 1) 1!11 r .-_ :1,,1 its.'*,01-'1,1'1 re-',•-rf ,'-.1.jlv' , ..,,,::„..Thr_:414:,,..::,:t , ,-,,,_- _ 1 jj YI - "*^.�..i. � t r , Y k.' .'z' 1 t , '1 y . ),,,, , .l 7 1'fr 1 .11 -,'"r4.------ 4..--,.. -C',, , Nu Y , _ i • '/ tur ,, 41' II • r. 5 i � :!, l . P ;1'', . Ti +Nn,~+ .. I� yF • 8 1 ..,_.',-.,� fir. - -.- " x.. 4 y 7 *, -. .z; .r x ;,f`•.- - it ! i xA ` SII \ __ ,� ud'1 a rasamiI �'. s,-4,,,.; irtt }�� Q.q lunignmennoi ice. CO VJ v w Q CO 6 , {itilr 4 No. Q {. ct 'Alt ' 1‘ ,, . #if*it gt ell--.).NI II AP li Ix a i. F di P 7b ' 4 i ir Ce (1:3 E , .,•r to ., . .., ....,,, . 1 i. , P - - , i i pi i .r iliolot, V ' MI 0 NZ W a 11 w I. __ W Rprime Y 60 LG38OQ1 K-A6 Preliminary 380W LG Solar's NeON®R Prime is a powerful solar module that provides premium performance.The NeON®R incorporates a cell structure without electrodes on the front to maximize light utilization and enhance reliability. Providing added value for the customer beyond efficiency,this module features an enhanced warranty,outstanding durability,solid performance in real-world r` conditions and aesthetic design suitable for roofs. ,F .APPROVED PRODUCT IA Ai D EUSC c\A {s. NI L�sr+:o KM 56457385 EN 61215 Photmrcetac Mold. Intertek 26, YEAR PRODUCT-PERFORMANCE•LABOR WARRANTY Features + Roof Aesthetics 25 Year Limited Product Warranty ®� LG NeON®R has been designed with aesthetics The NeON®R covered by a 25-year limited in mind:the lack of any electrodes on the front product warranty.In addition,up to$450 of creates an improved,modern aesthetic. labor costs will be covered in the rare case that a module needs to be repaired or replaced. Enhanced Performance Warranty More Generation Per Square Meter LG NeON®R has an enhanced performance The LG NeON®R has been designed to warranty.After 25 years,LG NeON®R is significantly enhance its output,making it guaranteed at least 92.5%of initial performance. efficient even in limited space. When you go solar, ask for the brand you can trust: LG Solar About LG Electronics USA,Inc. LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels and energy storage systems.The company first embarked on a solar energy source research program in 1985,supported by LG Group's vast experience in the semi-conductor,LCD,chemistry and materials industries.In 2010,LG Solar successfully LG released its first MonoX.series to the market,which is now available in 32 countries.The NeON°(previous Mono)[.NeON),NeON°2,NeON°2 BiFacial won the"Intersolar AWARD"in 2013,2015 and 2016,which demonstrates LG's leadership and innovation in the solar industry. Life's Good SOLARMOUNT mmi iLlimnri 11. 0 IN I MAL SOLARMOUNT defined the standard in solar racking. Features are designed to get installers off the roof faster. Our grounding & bonding process eliminates copper wire and grounding straps to reduce costs. Systems can be configured with standard or light rail to meet your design requirements at the lowest cost possible. The superior aesthetics package provides a streamlined clean edge for enhanced curb appeal, with no special brackets required for installation. END ii CAPS -..mmiall111111.111111.1"."'"-- 1 z n I NowFeaturing: FRONT THE NEW FACE OF SOLAR RACKING TRIM Superior Aesthetics Package . _ , [e FnNpEhkaGsey' f------ 1111 1 111 , I.,..i...... 'MI= . • - M. LOSE An OF THE COPPER & LUGS SMALL IS THE NEXT NEW BIG THING ENHANCED DESIGN & LAYOUT TOOLS System grounding through Enphase mioroinverters and trunk cables Light Rail is Fully Compatible with all SM Components Featuring Google Map Capabilities within U-Builder FAIT INSTALLATION. SUPERIOR AESTHETICS OPTIMIZED COMPONENTS • VERSATILITY • DESIGN TOOLS • QUALITY PROVIDER SOLARMOUNT .. ir uN1RAc OPTIMIZED COMPONENTS ..... INTEGRATED BONDING&PRE-ASSEMBLED PARTS 4,„#' ,i,,,..eol, .a 0 Components are pre-assembled and optimized to reduce installation steps and save 1� INTEGRATED BONDING I labor time.Our new grounding&bonding process eliminates copper wire and grounding A. MIDCLAMP straps or bonding jumpers to reduce costs.Utilize the microinverter mount with a wire management clip for an easier installation. VERSATILITY ..„.. ..,,„ ONE PRODUCT- MANY APPLICATIONS Quickly set modules flush to the roof or at a desired tilt angle. Change module INTEGRATED BONDING .1� orientation to portrait or landscape while securing a large variety of framed modules on (6SPLICE BAR " �, flat,low slope or steep pitched roofs.Available in mill,clear and dark anodized finishes ' 6to outperform your projects financial and aesthetic aspirations. oi ' �� AUTOMATED DESIGN TOOL DESIGN PLATFORM AT YOUR SERVICE *,� INTEGRATED BONDING Creating a bill of materials is just a few clicks away with U-Builder,a powerful online 6 tool that streamlinesthe process of designing a code compliant solar mounting system. 61 ;6 L-FOOTw/T-BOLT Save time by creating a user profile,and recall preferences and projects automatically when you log in.You will enjoy the ability to share projects with customers;there's no need to print results and send to a distributor,just click and share. INTEGRATED BONDING -a. MICROINVERTER MOUNT w/ WIRE MANAGEMENT BONDING&GROUNDWG A.a NuL21„3 MECHANICAL LOADING °° = Ul SYSTEM FIRE CLASSIFICATION UNIRAC CUSTOMER SERVICE MEANS THS HIGHEST LEVEL OF PRODUCT SUPPORT ry -41 1-1 . . . . ,___., 14 Al !° (6) IP UNMATCHED CERTIFIED ENGINEERING BANKABLE DESIGN PERMIT EXPERIENCE QUALITY EXCELLENCE WARRANTY TOOLS DOCUMENTATION TECHNICAL SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARRANTY Unirac's technical support team is dedicated to answering Unirac is the only PV mounting vendor with ISO certifications Don't leave your project to chance, Unirac has the financial questions & addressing issues in real time. An online for 9001:2015, 14001:2015 and OHSAS 18001:2007, strength to back our products and reduce your risk.Have peace library of documents including engineering reports, which means we deliver the highest standards for fit, of mind knowing you are receiving products of exceptional stamped letters and technical data sheets greatly form, and function. These certifications demonstrate our quality. SOLARMOUNT is covered by a twenty five (25) year simplifies your permitting and project planning process. excellence and commitment to first class business practices. limited product warranty and afive(5)yearlimited finish warranty. PROTECT YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN PU B2017FEB28-PRINTED Single Phase Inverter Z with H D-Wave Technology m for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / _170 SE7600H-US I SE10000H-US I SE11400H-US 412-25 r_ - YEAR 71° Q WARRANTY C� p •• solar,;'.� F4c� � rr�'�Mww • 0 1111O a o 0 a Optimized installation with HD-Wave technology Specifically designed to work with power optimizers UL1741 SA certified,for CPUC Rule 21 grid compliance Record-breaking 99% weighted efficiency Small, lightweight, and easy to install both outdoors or indoors Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Built-in module-level monitoring Fixed voltage inverter for longer strings Optional: Faster installations with built-in consumption metering (1% accuracy) and Integrated arc fault protection and rapid shutdown production revenue grade metering (0.5% accuracy, for NEC 2014, NEC 2017 and NEC 2020 per article ANSI C12.20) 690.11 and 690.12 solaredge.com 501 a r s � � 1 Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US I SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS SEXXXXH-XXXXXBXX4 WITH PART NUMBER OUTPUT 3800 @ 240V 6000 @ 240V 1 11400 @ 240V Rated AC Power Output 3000 5000 7600 I 10000 VA 3300 @ 208V 5000 @ 208V 10000 @ 208V 3800 @ 240V 6000 @ 240V 11400 @ 240V Maximum AC Power Output 3000 5000 7600 10000 VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. (211-240-264) i AC Output Voltage Min.-Nom.-Max. (183-208-229) v• ./ ./ Vac AC Frequency(Nominal) 59.3-60-60.5c) Hz Maximum Continuous Output ,, 12.5 21 25 32 42 47.5 A Current @240V Maximum Continuous Output Current @208V 16 24 48.5 A Power Factor 1,Adjustable-0.85 to 0.85 CFDI Threshold 1 A Utility Monitoring,Islanding Protection, Yes Country Configurable Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 i 9300 11800 15500 17650 W Maximum DC Power @208V 5100 I 7750 - 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 38C 400 Vdc Maximum Input Current @240V0 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @2081/0 9 13.5 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k2 Sensitivity Maximum Inverter Efficiency 99 99.2 % 99 @ 240V CEC Weighted Efficiency 99 % 98.5 @ 208V Nighttime Power Consumption <2.5 W (1)For other regional settings please contact SolarEdge support (2)A higher current source may be used;the inverter will limit its input current to the values stated Single PPhase Inverter with HD- Technology for N America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Metering,ANSI C12.20 Consumption metering Optional Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown NEC 2014 NEC Automatic Rapid Shutdown upon AC Grid Disconnect 2017 and NEC 2020,690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG DC Input Conduit Size/#of Strings/ 1"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/mm Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9 38.8/17.6 lb/kg Noise <25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to+140/-40 to+604 Protection Rating NEMA 4X(Inverter with Safety Switch) (3)Inverter with Revenue Grade Meter P/N:SExxxxH-U5000BNC4;Inverter with Revenue Grade Production and Consumption Meter P/N:SExxxxH-U5000BNI4.For consumption metering,current transformers should be ordered separately:SEACT0750-200NA-20 or SEACT0750-400NA-20.20 units per box (4)Full power up to at least 50°C/122°F;for power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills Single phase inverter with HD-wave technology and built-in RGM and Service Panel consumption monitoring Grid • rzT CT L1 N In 1=1 Shielded CAT5e cable L1 : -4111N- N =P er AC Conduit SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All R0 H S other trademarks mentioned herein are trademarks of their respective owners.Date:12/20201x01/ENG NAM.Subject to change without notice. Power Optimizer 0 For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 m 25 7C1 YEAR WARRANTY O . _ N m 71:1 PV power optimization at the module-level Specifically designed to work with SolarEdge Fast installation with a single bolt inverters Next generation maintenance with module- Up to 25% more energy level monitoring Superior efficiency (99.5%) Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Mitigates all types of module mismatch losses, Shutdown System (PVRSS) from manufacturing tolerance to partial shading Module-level voltage shutdown for installer and firefighter safety Flexible system design for maximum space utilization solaredge.com so I a r � � � Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 P340 P370 P401 (for higher- P400 P405 P485 P505 Optimizer model P320 (for high- power (for 72& (for high (for high- (for high- (for higher (typical module (for 60-cell power power 60 compatibility) modules) 60-cell 60 and 72- 96-cell and 72 cell voltage voltage current modules) cell modules) modules) modules) modules) modules) modules) INPUT Rated Input DC Power') 320 340 370 400 405 485 505 W Absolute Maximum Input Voltage 48 60 80 60 125° 83(2) Vdc (Voc at lowest temperature) MPPT Operating Range 8-48 8-60 8-80 8-60 12.5-105 12.5-83 Vdc Maximum Short Circuit Current 11 10.1 11.75 11 14 Adc (Isc) Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1+01 Vdc Optimizer STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),U0741 Material UL94 V-0,UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System 1000 Vdc Voltage Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(WsLsH) 129x153x27.5/51x6x1.1 129 x 153 x33.5 129 x153 x29.5 129x159x49.5/51x6.3x1.9 129 x162 x 59/ mm /51x6x1.3 /51 x 6 x 116 51 x 6.4 x 2.3 /in Weight(including cables) 630/1.4 750/1.7 655/1.5 845/1.9 1064/2.3 gr/lb Input Connector MC4(3) Single or dual MC4(3) P M C4(3)(4) Input Wire Length 006/0.52 m/ft Output Wire Type/Connector Double Insulated/MC4 Output Wire Length 0.9/2.95 1.2/3.9 m/ft Operating Temperature Range(5) -40-+85/-40-+185 °C/°F Protection Rating IP68/NEMA6P Relative Humidity 0-100 % (1)Rated power of the module at STC will not exceed the optimizer"Rated Input DC Power".Modules with up to+5%power tolerance are allowed (21 NEC 2017 requires max input voltage be not more than 80V (3}For other connector types please contact SolarEdge (41 For dual version for parallel connection of two modules use P485-4NMDMRM.In the case of an odd number of PV modules in one string,installing one P485 dual version power optimizer connected to one PV module.When connecting a single module seal the unused input connectors with the supplied pair of seals. (51 For ambient temperature above+85°C/+185°F power de-rating is applied.Refer to Power Optimizers Temperature De-Rating Technical Note for more details. PV System Design Using Single Phase Three Phase for Three Phase for a SolarEdge Inverter16t17t HD-Wave Single phase 208V grid 277/480V grid P320,P340,P370, Minimum String Length10 18 P400 P401 8 (Power Optimizers) P405,P485,P505 6 8 14 Maximum String Length(Power Optimizers) 25 25 508) 5700(6000 with Maximum Power per String SE7600-US-SE11400- 5250 60000) 1275010) W US) Parallel Strings of Different Lengths or Orientations Yes 161 For detailed string sizing information refer to:http://www.solaredge.com/sites/default/files/string_sizing_na.pdf (7)It is not allowed to mix P405/P485/P505 with P320/P340/P370/P400/P401 in one string (81 A string with more than 30 optimizers does not meet NEC rapid shutdown requirements;safety voltage will be above the 30V requirement (9)For 208V grid:it is allowed to install up to 7,200W per string when the maximum power difference between each string is 1,000W (10)For 277/480V grid:it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W ,ER, SolarEdge Technologies Ltd.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc. Ro H S All other trademarks mentioned herein are trademarks of their respective owners.Date:07/20201V02/ENG NAM.Subject to change without notice. 4101-is Intertek LG Ne0N®R Black Preliminary LG38OQ 1 K-A6 General Data Electrical Properties(STC*) Cell Properties(Material/Type) Monocrystalline/N-type Model LG380Q1K-A6 Cell Maker LG Maximum Power(Pmax) [W] 380 Cell Configuration 60 Cells(6 x 10) MPP Voltage(Vmpp) [V] 37.2 Module Dimensions(L x W x H) 1,740mm x 1,042mm x 40mm MPP Current(lmpp) [A] 10.21 Weight 18.5 kg Open Circuit Voltage(Voc,75%) [V] 43.5 Glass(Material) Tempered Glass with AR Coating Short Circuit Current(Isc,2 5%) [A] 10.85 Backsheet(Color) Black Module Efficiency [%] 21.0 Frame(Material) Anodized Aluminium Power Tolerance [%] 0--+3 Junction Box(Protection Degree) IP 68 with 3 Bypass Diodes *STC(Standard Test Condition):Irradiance 1000 W/m',cell temperature 25°C,AM 1.5 Measure Tolerance:±3% Cables(Length) 1,250mm x 2EA Connector(Type/Maker) MC 4/MC Operating Conditions Operating Temperature* [CC] -40--+85 Certifications and Warranty Maximum System Voltage [V] 1,000 IEC 61215-1/-1-1/2:2016,IEC 61730-1/2:2016, Maximum Series Fuse Rating [A] 20 UL 61730-1:2017,UL 61730-2:2017 Certifications'" Mechanical Test Load**(Front) [Pa/psf] 5,400 ISO 9001,ISO 14001,ISO 50001 MechanicalTest Load**(Rear) [Pa/psf] 4,000 OHSAS 18001 *The operating ambient temperature of these devices may exceed 40°C at full load for all wire sizes if is Salt Mist Corrosion Test IEC 61701:2012 Severity 6 determined suitable in the field use application. Ammonia Corrosion Test IEC 62716:2013 **Based on IEC 61215-2:2016(Test Load=Design Load x Safety Factor(1.5)) Module Fire Performance Type 2(UL 61730) Fire Rating Class C(UL 790,ULC/ORD C 1703) Packaging Configuration Product Warranty 25 Years Number of Modules per Pallet [EA] 25 Output Warranty of Pm ax Linear Warranty* Number of Modules per 40'Container [EA] 650 *Improved:1st year 98.5%,from 2-24th year:0.25%/year down,92.5%at year 25 **In Progress Number of Modules per 53'Container [EA] 850 Packaging Box Dimensions(L x W x H) [mm] 1,790 x 1,120 x 1,227 Packaging Box Dimensions(L x W x H) [in] 70.5 x 44.1 x 48.3 Temperature Characteristics Packaging Box Gross Weight [kg] 498 NMOT* [ °C] 44±3 Packaging Box Gross Weight [lb] 1,098 Pmax [%/°C] -0.29 Voc [%/°C] -0.24 lsc [%/°C] 0.04 Dimensions(mm/inch) *NMOT(Nominal Module Operating Temperature):Irradiance 800 W/mz,Ambient temperature 20°C, Wind speed 1 m/s,Spectrum AM 1.5 1042.0141.0(Size of Short Side) Electrical Properties(NMOT) 1002.0/39.4(Distance betuveen Grounding&Mounting Holes) AI IP. 40.0/1.57 Model LG380Q1K-A6 175.0/6.9.1411 r� IP./ �{ Maximum Power(Pmax) [W] 288 16-8.0x3.0/0.3x0.1�� A Drain Hales MPP Voltage(Vmpp) [V] 35.1 J� (-) I (+) 8-04.3/0.2 MPP Current(Impp) [A] 819 Grounding Holes Junction Box. ° A Open Circuit Voltage(Voc) [V] 41.6 8-8.5 x12.0/0.3x0.5 ° ° A Mounting Holes Short Circuit Current(Isc) [A] 8.75 N N 4J OJ Q Q1 1250.0/49.2 v -N Curves Cable Length . , 0 0 i7-, S E c � � O'A la' J 12.0 1000W N N N 91 D1 C f° U O� 10.0 800W tl `n a a vi_ 600W a a . 6.0 I I a a a a 400W U 4.0 200W o c- 2.0 fn A . r � © 07 i 0.0 p 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 T o -_ Voltage[V] / - - a a ._, L - LG Electronics USA,Inc. Product specifications are subject to change without notice. 0 LG Solar Business Division LG38OQ1 K-A6.pdf 2000 Millbrook Drive 121120 Lincolnshire,IL 60069 Life's Good www.lg-solar.com ©2020 LG Electronics USA,Inc.All rights reserved. Zimbra amber.upton@saratoga-springs.org Fwd: Solar Application for DRC: 718 N Broadway From :Amanda Tucker <amanda.tucker@saratoga-springs.org> Fri, Jun 11, 2021 10:13 AM Subject : Fwd: Solar Application for DRC: 718 N Broadway To :Amber Upton <amber.upton@saratoga-springs.org> 718 N. Broadway **Visit our website for the new 2021 Application Forms and Fee Schedule. Amanda Tucker, RA Senior Planner City Hall, Suite 32 474 Broadway Saratoga Springs, NY 12866 (518) 587-3550 ext. 2517 From: "Sandra Caulfield" <secmail888@yahoo.com> To: "Tamie Ehinger" <tamieehinger@yahoo.com>, "Amanda Tucker" <Amanda.Tucker@saratoga-springs.org> Cc: "Samantha Bosshart" <sbosshart@saratogapreservation.org> Sent: Thursday, June 10, 2021 4:52:06 PM Subject: Fw: Solar Application for DRC: 718 N Broadway CAUTION: This email originated outside of the City network. Please contact IT Support if you need assistance determining if it's a threat before opening attachments or clicking any links. Hi, Tamie and Amanda: Samantha Bosshart forwarded me the DRC application submitted by Kasselman Solar LLC to add solar panels to my garage this afternoon. After looking at the detailed layout of the solar panels (last page of the application), both my husband, Thomas Caulfield, and myself, do not want to mount the three north facing solar panels. We would prefer not to see any panels on the front/north facing elevation of our garage roof. Please contact me if you have additional questions. Tom is traveling. Thank you, Sandra Eng-Caulfield Forwarded Message From: Samantha Bosshart <sbosshart@saratogapreservation.org> To: Sandra Caulfield <secmail888@yahoo.com> Sent: Thursday, June 10, 2021, 03:52:17 PM EDT Subject: Solar Application Sandra,