20210519 718 N Broadway PV Array Roof Application
**HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED** jFOROFFICE USEl CITY OF SARATOGA SPRINGS (Application#) DESIGN REVIEW COMMISSION CITY HALL-474 BROADWAY (Date received) J SARATOGA SPRINGS, NEW YORK 12866-2296 i"coRPoRA Eo a` TEL: 518-587-3550 X2533 www.saratoga-springs.org (Project Title) APPLICATION FOR: ARCHITECTURAL/HISTORIC REVIEW Staff Review APPLICANT(S)* OWNER(S) (if not applicant) ATTORNEY/AGENT Name Loreen Harvey: Kasselman Solar, LLC. Thomas Caulfield Loreen Harvey Address 20 Walker Way 718 N Broadway 20 Walker Way Albany, NY 12205 Saratoga Springs, NY 12866 Albany, NY 12205 Phone (518)478- 390k (650)450-2667/ (518)478-3996 Email Iharvey@kasselmansolar.com thomas.caulfield@globalfoundries.com lharvey@kasselmansolar.com Identify primary contact personpplicant 0 Owner 5ttorney/Agent *An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant's interest in premises: [caner 0 Lessee 0 Under option to lease or purchase PROPERTY INFORMATION Property Address/Location: 718 N Broadway, Saratoga Springs, NY 12 Tax Parcel #: 165 36 - 2 - 1 .1 (for example: /65.52-4-37) Date Acquired by Owner: 10/30/14 Current Zoning District: URI Property use:residential 0 Non-residential/mixed-use Type of Review: 0 Architectural 1-listoric 0 Extension/modification (of current approval) Summary description of proposed action: Installation of a 8.36 kW (22 panels) roof-mounted PV array. Has a previous application been filed with the DRC for this property? IR No 0 Yes-date(s)? -App. No.(s)? Revised 01/2021 **A "complete" application consists of 1 hard copy(original) , and I electronic copy of application &ALL other materials as required below: New Construction/Additions ❑ Color photographs showing site/exterior details of existing structures and adjacent properties ❑ Site plan,drawn to scale,showing existing&proposed construction, property lines&dimensions, required &proposed setbacks&lot coverage,site features(fences,walks,trees,etc.);on no larger than 2'x3'sheet—smaller preferred if legible ❑ Elevation drawings showing design of all sides of existing&proposed construction—label dimensions,colors, materials, lighting(fixture &lamp type,wattage),etc. -include compass bearing&scale; no larger than 2'x3'sheet—smaller permitted if legible ❑ Floor plans for proposed structure;on sheet no larger than 2'x3'—smaller permitted if legible ❑ Product literature,specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) ▪ Color photographs showing site/exterior details of existing structures and that illustrate affected features ▪ Elevation drawings showing all sides of existing&proposed construction—label dimensions,colors, materials, lighting(fixture&lamp type,wattage),etc. -include compass bearing&scale; no larger than 2'x3'sheet—smaller permitted if legible ▪ Product literature,specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts only (Front setbacks:UR-I &INST-1-1TR=30';UR-4=25';UR-2,UR-3&NCUD-I=10') - Installation, removal or change in material of drive-and walkways - Installation or removal of architectural, sculptural or vegetative screening over 3' in height - Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2' diameter) For any of above: ❑ Color photographs showing site/exterior details of existing structures,and of adjacent properties ❑ Site plan showing existing&proposed construction: include property lines&dimensions, required &proposed setbacks&lot coverage,site features(fences,walks,trees,etc.) street names,compass bearing&scale; no larger than 2'x3'sheet—smaller preferred if legible ❑ Product literature,specifications and samples of proposed materials and colors Signage/Awnings ❑ Color photographs showing site/exterior details of existing structures,and adjacent properties ❑ Plan showing location of proposed sign/awning structure on building/premises: no larger than 11"x17" ❑ Scaled illustration of proposed sign/awning structure and lettering(front view&profile): include all dimensions of structure;type, dimensions and style of lettering or logo;description of colors, materials, mounting method and hardware ❑ Descriptions,specifications of proposed lighting including fixture&lamp type,wattage, mounting method,and location ❑ Product literature,specifications and samples of proposed materials and colors Demolition ❑ Color photographs showing site/exterior details of existing structures,and of adjacent properties ❑ Site plan showing existing and any proposed structures-include dimensions,setbacks,street names,compass bearing,and scale ❑ Written description of reasons for demolition and, in addition: ❑ For structures of"architectural/historical significance",demonstrate"good cause"why structure cannot be preserved ❑ For structures in an architectural district that might be eligible for listing on National Register of Historic Places,or for a "contributing"structure in a National Register district(contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities ❑ Color photographs showing site/existing structures, and of adjacent properties ❑ Site plan showing existing and proposed structures: include dimensions,setbacks,street names,compass bearing,and scale ❑ Scaled illustration of proposed structures: include all dimensions;colors, materials, lighting, mounting details ❑ Consult Article 240-12.22 of the City's Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 01/2021 Request for extension of current approval ❑ Identify date of original DRC approval: Current expiration date: Org.App. No. ❑ Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEQR Environmental Assessment Form ❑ Applicants proposing the following must complete"Part I" of the SEQR Short Environmental Assessment Form (available here: http://www.dec.ny.gov/docs/permits_ej_operations_pdf/seaf partone.pdf): - Construction or expansion of a multi-family residential structure (4 units +) - Construction or expansion (exceeding 4,000 sq.ft.gross floor area)of a principal or accessory non-residential structure -Telecommunications facility, radio antennae, satellite dishes - Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? E No 0 Yes- If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification I/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Commission. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review of the Zo ' Code of the City of Saratoga Springs. Q Date: 5/8/2 1 applic.• signature) Date: (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature: See attached Date: Owner Signature: Date: Revised 01/2021 2021 LAND USE BOARD FEE WORKSHEET OPED Fees Type 2021 Fee Application to Zoning Board of Appeals[1][2] TOTAL #VARIANCE Use Variance $1100+$50/app Area Variance-Residential $275/var+$50/app+$125 eachadd'I variance Area Variance-Multi-Family,Comm,Mixed-Use $660/var+$50/app+$200 eachadd'I variance Interpretations $550+$50/app Post-Work Application Fee Add 50%App fee+$50/app Variance extensions 50%ofApp fee+$50/app Application to Design Review Commission[1] TOTAL #STRUCTURE Demolition I $385 Residential Structures Principal $55 Accessory $55.00 $55 Extension $35 Modification $55 Multi-Family,Comm,Mixed-Use Structures Sketch $165 Principal $550 Extension $200 Modification $330 Multi-Family,Comm,Mixed-Use Accessory,Signs,Awnings Principal $140 Extension $75 Modification $140 Post-Work Application Fee Add 50%App fee Application to Planning Board[1] TOTAL #STRUCTURE Special Use Permit[2] $990+$50/app Special UsePermit-extension $330 Special UsePermit-modification[2] $450+$50/app Site Plan Review-incl.PUD: Sketch Plan $330 Residential $330+$200/unit Residential-extension $200 Residential-modification $400 Non-residential $660+$130/1000 sf Non-Residential-extension $300 Non-Residential-modification $650 Subdivision-incl.PUD: TOTAL #LOTS Sketch Plan I $330 Preliminary Approval[2] Residential:1-5 lots $660+$50/app Residential:6-10 lots $990+$50/app Residential:11-20 lots $1320+$50/app Residential:21+lots $1650+50/app Residential-extension $330 Final Approval[2] Residential $1320+$175/lot+$50/app Non-Residential $2000/lot+$50/app Final Approval Modification[2] Residential $330+$50/app Non-Residential $550+$50/app Final Approval Extension Residential $135 Non-Residential $330 Other: TOTAL #LOT/ACRE Post-Work Application Fee Add 50%App fee Lot Line Adjustment $350 Letter of Credit-modification or extension $440 Letter of Credit-collection up to 1%ofLoC Recreation Fee $2000/lotorunit Land Disturbance $660+$55/acre SEQRA EIS Review(Draft&Final) TBD Legal Noticing if PB requires Public Hearing $50/app [1] Fees are based on per structure,except where noted. $55.00 TOTAL DUE [2] Legal ad required;includes City processing and publishing For Administrative Use Total Paid at Intake Revised Fee Balance Due / / Balance Paid Staff approval DocuSign Envelope ID:4CCDAB75-3B0B-4C73-96FC-23BF356DB500 20 Walker Way K ka ss e l m n Colonie, NY 12205 (518)-478-8365 (518)-953-1095 Fax Thomas Caulfield I (Customer) hereby authorize Kasselman Solar LLC,to act as customer, agent& contractor, and to submit all necessary permit applications and supporting documents to the Town Building Department on my behalf. Thomas Caulfield Customer Name(Print) t,6w1G.S CrAtOd,j, Customer Signature 718 N Broadway Saratoga Springs New York 12866 Customer Address Saratoga Springs Municipality Kasselman Solar Employee Signature 199 CHURCH STREET,NEW YORK,N.Y.10007-1100 New York State Insurance Fund I nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE AAAAAA 464740969 p q,l , LOVELL SAFETY MGMT CO.,LLC ;_: 'L+, 110 WILLIAM STREET 12TH FLR � •i' t{.�_ NEW YORK NY 10038 ••'dam fio�- SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER KASSELMAN SOLAR LLC CITY OF SARATOGA SPRINGS 20 WALKER WAY 474 BROADWAY ALBANY NY 12205 SARATOGA SPRINGS NY 12866 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z 2329 433-3 106773 04/01/2021 TO 04/01/2022 03/17/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2329 433-3, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW,AND,WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK,TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS' COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 967323449 (III IINIIIIIII0001000T0TTI9155MI IIIIIIIIIIIIII Form WC-CERT-NOPRINT Version 3(08/29/2019)[WC Policy-23294333] U-26,3 380 [00000000000091552160][0001.000023294333][##2)[15594-05][CerLNoP-CERT_1][01-00001] Client#: 34297 KASSESOLAR YYYY) M/DD/ ACORD,,ACORD,, CERTIFICATE OF LIABILITY INSURANCE 3124/2021 DATE(MM/DD/ THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Maureen A. Nicholas NAME: Cool Insuring Agency Inc CL (A/2,NNo,Ext):518 783-2665 FAX5187838754 (A/C,No): 784 Troy Schenectady Road A oRILSS: manicholas@coolins.com Latham, NY 12110 518 783-2665 INSURER(S)AFFORDING COVERAGE NAIL# INSURERA:Southwest Marine&General Insurance Co 12294 INSURED INSURER B:Travelers Property Cas Co of America 25674 Kasselman Solar LLC ShelterPoint Life Insurance Company81434 20 Walker Way INSURERC: INSURERD:NGM Insurance Company 14788 Albany, NY 12205 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. R POLICY EFF POLICY EXP TYPE OF INSURANCE NSR WVD POLICY NUMBER LTR (MM/DD/YYYY) (MM/DD/YYYY) LIMITS A X COMMERCIAL GENERAL LIABILITY GL202100011431 03/24/2021 03/24/2022 EACH OCCURRENCE $1,000,000 D CLAIMS-MADE X OCCUR DAMAGE O(Eaoccurrrence) $300,000 X PD Ded. $5,000 MED EXP(Any one person) $5,000 PERSONAL 8.ADV INJURY $1,000,000 GENL AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 POLICY X JECRO- T LOC PRODUCTS-COMP/OPAGG $2,000,000 OTHER: $ D AUTOMOBILE LIABILITY B2U4697P 03/24/2021 03/24/2022 COMBINccidenEDt)SINGLE LIMIT _$1,000,000 (Ea a X ANY AUTO BODILY INJURY(Per person) $ X AUTOS ONLY X SCHEDULED AUTOS BODILY INJURY(Per accident) $ X AUTOS ONLY X NON-OWNED PROPERTY DAMAGE AUTOS ONLY (Per accident) A X UMBRELLA LIAB X OCCUR EX202100001814 03/24/2021 03/24/2022 EACH OCCURRENCE $2,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $2,000,000 DED X RETENTION$10,000 $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ B Installation QT6307R182782TIL21 03/24/2021 03/24/2022 $500,000 C Disability DBL441239 03/24/2021 Continuous NY Statutory DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Project: All Projects Certificate Holder is added to the General Liability coverage as Additional Insured if required by written contract with respect to the above project. CERTIFICATE HOLDER CANCELLATION ANY OFDESCR City of Saratoga Springs THE SHOULD EXPIRATION E DATE E VTHEREOFED NOTTICEIES WIBLL E CELLED BE CDELIVERED NE Building Department ACCORDANCE WITH THE POLICY PROVISIONS. 474 Broadway Saratoga Springs, NY 12866 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016103) 1 of 1 The ACORD name and logo are registered marks of ACORD #51243380/M1243194 CMG 1 r"oec I Workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation under the NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW Board PART 1. To be completed by Disability Benefits Carrier or Licensed Insurance Agent of that Carrier 1a. Legal Name and Address of Insured(Use street address only) 1b.Business Telephone Number of Insured 518 478-8365 Kasselman Solar LLC 1c.NYS Unemployment Insurance Employer Registration 20 Walker Way Number of Insured Albany,NY 12205 1 d.Federal Employer Identification Number of Insured or Social Security Number 464740969 2. Name and Address of the Entity Requesting Proof of 3a. Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company City of Saratoga Springs; Building Department 3b.Policy Number of entity listed in box"Ia": 474 Broadway DBL441239 Saratoga Springs,NY 12866 3c. Policy effective period: 03/24/2021 to 03/24/2022 4.Policy provides the following'benefits: a. ® Both disability&paid family leave benefits b. ❑ Disability benefits only. c. ❑.Paid family leave benefits only 5.Policy Covers:: a. ® All of the employer's employees eligible under the New York Disability&Paid Family Leave Benefit Law b. ❑ Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability Benefits insurance coverage as described above. Date Signed March 5,2021 By (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number (800)233-0115 Title Authorized Representative IMPORTANT: If box"4a"is checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If box"4b,4c or 5b"is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board,DB Plans Acceptance Unit,20 Park Street,Albany,New York 12207. PART 2. To be completed by NYS Workers' Compensation Board (Only if box"4b" of Part 1 has been checked) State Of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability Benefits Law with respect to all of his/her employees. Date Signed By (Signature of NYS Workers'Compensation Board Employee) Telephone Number Title Please Note: Only insurance carriers licensed to write NYS disability benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. III N11 111#1111111011#111111 DB-120.1 (9-17) Additional Instructions for Form DB-120.1 By signing this form,the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in box"i a"for disability and/or paid family leave benefits under the New York State Disability and Paid Family Leave Benefits Law.The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is cancelled due to nonpayment o f premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate.(These notices my be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policyexpiration date listed in Box 3c,whichever is earlier This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend,extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Disability and/or Paid Family Leave Benefits contract of insurance only while the underlying policy is in effect. Please Note:Upon the cancellation of the disability and/or paid family leave benefits policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holderwith a new Certificate of NYS Disability and/or Paid Family Leave Benefits Coverage or other authorved proof that the business is complying with the mandatory coverage requirements of the New York State Disability and Paid Family Leave Benefits Law. DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220.Subd. 8 (a)The head of a state or municipal department,board,commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article,and not withstanding any general or special statute requiring or authoriz ing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first,two thousand and twenty-one,the payment of family leave benefits for all employees has been secured as provided by this article.Nothing herein,however,shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b) The head of a state or municipal department,board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract,shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first,two thousand eighteen,the payment of family leave benefits for all employees has been secured as provided by this article. - P DB-120.1 (9/17)Reverse lovi= WESTSHORE DESIGN ENGINEERS, P.C. 100 GREAT OAKS BLVD. I SUITE 117A ALBANY I NEW YORK I 12203 To: Kasselman Solar 20 Walker Way Albany, NY 12205 Date: April 21, 2021 Ref.: 21040216 Subject: Caulfield Residence 718 North Broadway St. Saratoga Springs, NY To Whom It May Concern, The following references the structural roof analysis of the Caulfield residence located in Saratoga Springs, NY. Westshore Design Engineers has been retained in order to analyze the existing roof structure for adequacy in supporting the proposed additional loading due to rooftop solar panels. The site-specific loadings are as follows: Seismic Design Category C; basic Wind Speed of 115mph; and Ground Snow Load of 50psf, per ASCE 7-16. The Applicable codes also include the 2020 Residential Code of NYS. The existing roofs consist of 2x10 at 16"o.c. with an 11'-4" span. Based on structural analysis, it has been determined that the R1, R2, R3 and R4 roofs are adequate to support rooftop solar panels with a maximum loading of 3psf. "Unirac" L-foot anchors or equal with 5/16" diameter lags required at 48" on center maximum, staggered, with 2.5" minimum embed or S-5! Clamps or equal for metal roofs. RoofTech"RT Mini" or equal attachments for deck attachments. Please don't hesitate to contact us with additional requests. 0 NE�y Thank you. o�P s a .N2" 0 ` fI Westshore Design Engineers * ; EXP ;},14i,- 111 07/24 Ar, 41 FOP °91373 ROFES S100 4/21/2021 John Eibert Nicolas Nitti, PE Director of Solar Operations President WestShore Design Engineers 11100 Great Oaks Blvd. II Suite 117A II Albany,NY 12203 II 518.313.7153 Customer: Thomas and Sandra Caulfield 718 N Broadway Saratoga Springs , New York 12866 Address: Phone: 650450-2667** 22 LG 380 W Modules 22 SolarEdge P 401 Power Optimizers 1 7.6k SolarEdge HD Wave Inverter 11 LG 380 W modules System Size (kW) 8.36 11 SolarEdge P 401 Power Optimizers 7.6k MSP AI- Y i i • 12/3 MC SolarEdge HD Wave Inverter 200 A Main Dom: _ 60 A Disconnect 30 A Fuses1 2 1 DC #4 SER 200 A Bus •11 LG 380 W modules - THHN-2 4/0 URD 4#10 AWG PV /#8 AC 1 #10GND ATS # I M 11 SolarEdge P 401 Power Optimizers I. #10 GND i I 1" Conduit -- 1r i__. " Conduit GO . . 12/3 MC 1 2 Utility: National Grid Acct# 48988-92123 Meter# 31416341 Kasselman Solar 20 Walker Way Albany NY 12205mansoLAR . K 518-320-7669 SOLARMOUNT END LEGEND ENGINEER (N) E-MOUNT MOUNT OR MID 11 11 11 CAULFIELD RESIDENCE 718 NORTH BROADWAY .04"THICK 9"x12" MOUNT AS REQ'D PER 11 11 11 SOLAR MODULE ALUMINUM ........... MFGR. 1i ii ii SARATOGA SPRINGS, NY 22 SOLAR MODULES (46"X39" EA.) W/22 OPTIMIZERS FLASHING (N) SOLAR PANEL INSTALLED TO RAILS IN 4 LOCATIONS PER MANUFACTURER —" (N) UNIRAC RAIL *PV DESIGN ADHERES TO SECTION SPECIFICATIONS. y w v R234-SOLAR ENERGY SYSTEMS OF THE Fr, ?o (E) ROOF SURFACE 2015 IBC AND NYS ERRATA AMENDMENTS - UNIRAC SOLAR MOUNT RAIL SYSTEM RAILS ARE z (N) SOLARMOUNT AS ADOPTED BY NYS CENTERED UNDER PANEL SEAMS. W = o (N) E-MOUNT CAST , J> _ L FOOT PER - RAFTER SPACING = 16"O.C. w m z MFGR.w/3/8"0 ALUMINUM MOUNTING - RAIL TO ROOF MOUNT: QUICKMOUNT PV E-MOUNT a o; BOLT & 5/8"0 BLOCK PER MFGR. LAG w/5/8"0 LAG SCREW. N w a M LAG SCREW w 3 N m `,'° EMBED MIN. NOTES: 1. RAIL TO ROOF ATTACHMENTS SHALL BE 4' O.C. MAX. TYPICAL ATTACHMENT DETAIL 2 AND LAGGED INTO A RAFTER 2. IF THE LAG BOLT CANNOT BE INSTALLED IN A RAFTER, 1"=1 '-0" SOLID BLOCKING SHALL BE ADDED BETWEEN ALL RIGHTS RESERVED.NO RAFTERS TO ALLOW FOR LAG INSTALLATION. PART OF THESE DRAWINGS OR SPECIFICATIONS MAY BE 3. ALL MANUFACTURER'S INSTRUCTIONS AND SUCED OR EDOI IN CONNECED TION WITH OTHER THEN SPECIFICATIONS SHALL BE FOLLOWED FOR THE ANY EOCFCPROJECTFORHE PRODUCTS USED. WHICH THEY BEEN PREPARED,WITHOUT PRIOR WRITTEN AUTHORIZATION 4. SOLAREDGE OPTIMIZER FOR EACH MODULE FROM THE ENGINEER J/ ROOF DIMENSIONS SHOWN AS MEASURED ON ROOF; /ROJ.NUMBER:21 04045\\ HORIZONTAL PROJECTIONS ARE NOT SHOWN. GROUND ACCESS ZONE DIMENSIONS PROVIDED BY KASSELMAN SOLAR N 11 ROOF z 1 ACCESS ZONE, — 1 TYP. m I I I I It -i 1 11 1 1 1 II — U 1 1 1 1 1 11 ~ I I I I I II II II I II 1 11 1 0 11 11 1 11 1 I 1 1 1 1 1 1 1 I 1 1 1 1 1 , NEW ROOF ARRAY,TYP. II II II II 1 11 I H I I II II 11 / ` 1 1 1 1 H I 11 1 II 1 11 I DRAWN BY: JE I II 11 11 II II II II II II 11 11 1 11 I CHECKED BY:NN 11 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 1 `DATE: 4-21-2021•00° II II II II II II II II II II J II II II II II II II II II II APPLICABLE BUILDING CODES: oo0° II II II II II II II II II 1 1 ROOF \ 1 1 1 1 I I 1 1 1 1 I I I I 1 1 1 1 1 1 I I 1 1 1 1 I I I I 1 1 2020 NYS RESIDENTIAL CODE P R O J E C T ii ii ii ii ii ii ii ii ii ii ii ii ii II II 1 1 ACCESS - ASCE 7-16 pF NE* / 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 ZONE, *0- `O�pS A ,,ylTyO / II II II II II II II II II II II II II II II 1 1 TYP. DESIGN CRITERIA PER ASCE 7-16: CAULFIELD RESIDENCE � , -p 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 (' ( SEISMIC DESIGN CATEGORY: BGROUND ACCESS ZONE TRUE NORTH � Al..-4*.'-- W GROUND SNOW LOAD: 50PSF NORTH TITLE . ..t"... r <0 091373 ��� \ SOLAR PLAN & „ N \. \ ATTACHMENTDETAIL R ESSIO P 4-21-2021 SHEET SOLAR ARRAY PLAN 1 S1 00 ' 1/8" = ,-0, ELECTRICAL SERVICE ENTRY/ O ,</ -METER MSP/AC DISCONNECT(INTERIOR N1Sp 4 WALL)-WHOLE HOUSE GENERATOR RESIDENCE ialGRouNoA00Fss/�100 A Sub Panel located in garage I RO No SSS c 1. Zo 0000 11OPP R4 11111:1141104 in R1 Alir 11-4474710 4 0, II OG�� O R2 Uw Q 2 O N PV Design adheres to solar photovoltaic relevant sections of the 2020 Residential Code[R324]of NYS and 2020 Fire Code of NYS[1204] Design Prepared by:Scott Stevens Director of PV Design&Engineering Installation Details: Roof Description: I_ :Solar Photovoltaic Module and DC Thomas Caulfield System Size: 8.36 R1-R4:SHINGLE 15-DEGREE TILT I� Optimizer/Microinverter 22 LG Electronics Inc. LG380Q1 K-A6 RAFTER/TRUSS:16"o.c.(2x10) :Setbacks in accordance with sections 1204(IFC,2020)and 718 North Broadway R1 AZIMUTH @ 286-DEGREES(W) R324(IRC 2020)Horizontal ridge not less than 18"Pathways Saratoga Springs, NY 22 SolarEdge Technologies Inc. P401 R2 AZIMUTH @ 196-DEGREES(S) not less than 36" 1 SolarEdge Technologies Inc. SE7600H-US R3 AZIMUTH @ 106-DEGREES(E) UNIRAC SOLAR MOUNT R4 AZIMUTH @ 16-DEGREES(N) Install Notes: ka s e I m d n o L /[kMr+j Contains confidential,proprietary,and/or privileged information Whole House Generator I'C April 21st,2021 I( kasselman : 718 North Broadway Saratoga Springs, NY SITE DESIGN 3D { , '„,,i ___ — ;. Tom+, ` T g Y f y —_ o l'' V 3^r.6 t., - __`- n Bid z, •,..el _ A I "I. S. r 4 • of NI 1\41.1\spossillyi, 11111100. 11114 tis 0100 irti -IL ;::: r ifs di dP, 3 ; ISI 'III ' ®f1 , `. "lin i e -- ! 1• T I '� f' 1 ..:sem- NI@°I, 1 , .+`% ' k +_ , •,. ire t ?; a SLS!_.. L.A; .•m� r PAN . 111 ROTATE LG N ON R Prime 60 LG380Q1 K-A6 Preliminary 380W LG Solar's NeON°R Prime is a powerful solar module that provides premium performance.The NeON°R incorporates a cell structure without electrodes on the front to maximize light utilization and enhance reliability. Providing added value for the customer beyond efficiency,this module features an enhanced warranty,outstanding durability,solid performance in real-world conditions and aestheticl_ design suitable for roofs. DVE V DS CE APPROVED PRODUCT Intertek 1- 25 YEAR PRODUCT•PERFORMANCE•LABOR WARRANTY Feature! + Roof Aesthetics 25-Year Limited Product Warranty LG NeON°R has been designed with aesthetics The NeON°R covered by a 25-year limited in mind:the lack of any electrodes on the front product warranty.In addition,up to$450 of creates an improved,modern aesthetic. labor costs will be covered in the rare case that a module needs to be repaired or replaced. Enhanced Performance Warranty More Generation Per Square Meter LG NeON®R has an enhancedperformance 6 The LG NeON®R has been designed to " 9 warranty.After 25 years,LG NeON°R is significantly enhance its output,making it guaranteed at least 92.5%of initial performance. efficient even in limited space. When you go solar, ask for the brand you can trust: LG Solar About LG Electronics USA,Inc. �� LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels and energy storage systems.The company first embarked on a solar energy source research program in 1985,supported by LG Group's vast experience in the semi-conductor,LCD,chemistry and materials industries.In 2010,LG Solar successfully released its first MonoX°series to the market,which is now available in 32 countries.The NeONe(previous MonoXe NeON),NeONe2,NeONe2 BiFacial won the"Intersolar AWARD"in 2013,2015 and 2016,which demonstrates LG's leadership and innovation in the solar industry. Life's Good SOLARMOUNT II: UNIRAC SOLARMOUNT defined the standard in solar racking. Features are designed to get installers off the roof faster. Our grounding & bonding process eliminates copper wire and grounding straps to reduce costs. Systems can be configured with standard or light rail to meet your design requirements at the lowest cost possible. The superior aesthetics package provides a streamlined clean edge for enhanced curb appeal, with no special brackets required for installation. END CAPS z -- D I • Now Featuring: FRONT THE NEW FACE OF SOLAR RACKING TRIM Superior Aesthetics Package Fes,, R;;; 11141. LOSE ALL OF THE COPPER & LUGS SMALL IS THE NEXT NEW BIG THING ENHANCED DESIGN & LAYOUT TOOLS System groundingthrough Enphase microinverters and trunk cables Light Rail is Fully Compatible with all SM Components Featuring Google Map Capabilities within U-Builder FAST INSTALLATION. SUPERIOR AESTHETICS „„„„„„„„„„„,„„„„„„„„„„„,„„„„„„„„„„„,„„„„„„„„„„„,„„„„„„„„„„„,„„„„„„„„„„„,„„„„„„„„„„„,„„„„„„„„„„„,„„„„„„„„„„„,„„„„„„„„„„„,„„„„„„„„„„„,„„„„„„„„„„„,„„„„„„„„„„„,„„„„„„„„„„„,„„„„„„„„„„„,„„„„„„„, OPTIMIZED COMPONENTS • VERSATILITY • DESIGN TOOLS • QUALITY PROVIDER SOLARMOUNT .;: uNIRAc OPTIMIZED COMPONENTS INTEGRATED BONDING&PRE-ASSEMBLED PARTS Components are pre-assembled and optimized to reduce installation steps and save INTEGRATED BONDING labor time.Our new grounding&bonding process eliminates copper wire and grounding MIDCLAMP straps or bonding jumpers to reduce costs.Utilize the microinverter mount with a wire management clip for an easier installation. VERSATILITY ONE PRODUCT-MANY APPLICATIONS Quickly set modules flush to the roof or at a desired tilt angle. Change module INTEGRATED BONDING1 SPLICE BAR orientation to portrait or landscape while securinga large variety of framed modules on � � 4 flat,low slope or steep pitched roofs.Available in mill,clear and dark anodized finishes to outperform your projects financial and aesthetic aspirations. 'i AUTOMATED DESIGN TOOL DESIGN PLATFORM AT YOUR SERVICE Creating a bill of materials is just a few clicks away with U-Builder,a powerful online t ® INTEGRATED BONDING tool that streamlinesthe process of designing a code compliant solar mounting system ® ; L-FOOTw/T-BOLT Save time by creating a user profile,and recall preferences and projects automatically when you log in.You will enjoy the ability to share projects with customers;there's no need to print results and send to a distributor,just click and share. INTEGRATED BONDING 4iV : MICROINVERTER MOUNT w/ .v WIRE MANAGEMENT 0.ingBONDING&GROUNDING \/ O N u LL lua MECHANICAL LOADING SYSTEM FIRE CLASSIFICATION UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT Al :/' (6) UNMATCHED CERTIFIED ENGINEERING BANKABLE PERMIT EXPERIENCE QUALITY EXCELLENCE WARRANTT DOCUMENTATION TECHNICAL SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARRANTY Unirac's technical support team is dedicated to answering Unirac is the only PV mounting vendor with ISO certifications Don't leave your project to chance, Unirac has the financial questions & addressing issues in real time. An online for 9001:2015, 14001:2015 and OHSAS 18001:2007, strength to back our products and reduce your risk.Have peace library of documents including engineering reports, which means we deliver the highest standards for fit, of mind knowing you are receiving products of exceptional stamped letters and technical data sheets greatly form, and function. These certifications demonstrate our quality. SOLARMOUNT is covered by a twenty five (25) year simplifies your permitting and project planning processexcellence and commitment to first class business practiceslimited product warranty and afive(5)year limited finish warranty. PROTECT YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN PUB2017FEB28-PRINTED Single Phase Inverter Z with for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US m 1 -25 YY YEAR AR Q ARRANTY o C 0 o €1 solar,LC „_, ,'p.,,,,,, solar: -AHD:._:_.,. a r a w 9 4 4111 0 a 0 iF I Optimized installation with HD-Wave technology Specifically designed to work with power optimizers UL1741 SA certified,for CPUC Rule 21 grid compliance Record-breaking 99% weighted efficiency Small, lightweight, and easy to install both outdoors or indoors Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Built-in module-level monitoring Fixed voltage inverter for longer strings Optional: Faster installations with built-in consumption metering (1% accuracy) and Integrated arc fault protection and rapid shutdown production revenue grade metering (0.5% accuracy, for NEC 2014, NEC 2017 and NEC 2020 per article ANSI C12.20) 690.11 and 690.12 solaredge.com solar Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS SEXXXXH-XXXXXBXX4 WITH PART NUMBER OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211-240-264) AC Output Voltage Min.-Nom.-Max. - ✓ - ✓ - - ✓ Vac (183-208-229) AC Frequency(Nominal) 59.3-60-60.5(1) Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current©240V Maximum Continuous Output 16 24 48.5 A Current©208V Power Factor 1,Adjustable-0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring,Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power©240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power©208V - 5100 - 7750 - - 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current©240V(2) 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current©208V(2) - 9 - 13.5 - - 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600L2 Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V Nighttime Power Consumption <2.5 W (1)For other regional settings please contact SolarEdge support (2)A higher current source may be used;the inverter will limit its input current to the values stated Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Metering,ANSI C12.20 ) Consumption metering Optionall3 Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown-NEC 2014,NEC Automatic Rapid Shutdown upon AC Grid Disconnect 2017 and NEC 2020,690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG DC Input Conduit Size/#of Strings/ 1"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/mm Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9 38.8/17.6 lb/kg Noise <25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to+140/-40 to+60° F/ C Protection Rating NEMA 4X(Inverter with Safety Switch) (3)Inverter with Revenue Grade Meter P/N:SExxxxH-US000BNC4;Inverter with Revenue Grade Production and Consumption Meter P/N:SExxxxH-US000BNI4.For consumption metering,current transformers should be ordered separately:SEACT0750-200NA-20 or SEACT0750-400NA-20.20 units per box (4)Full power up to at least 50°C/122°F;for power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills Single phase inverter with HD-wave technology and built-in RGM and Service Panel consumption monitoring L Grid �! © I OTTT 0 F�{>� Shielded CAT5e cable _ad r+II, L1 • +►■ N V AC Conduit SolarEdge Technologies,Inc All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All Ro LJ S other trademarks mentioned herein are trademarks of their respective owners.Date:12/2020/VOl/ENG NAM.Subject to change without notice. R �7�7 Power Optimizer O For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 m 25 ' YEAR WARRANTY O )1 N m PV power optimization at the module-level Specifically designed to work with SolarEdge Fast installation with a single bolt inverters Next generation maintenance with module- Up to 25% more energy level monitoring Superior efficiency (99.5%) Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Mitigates all types of module mismatch losses, Shutdown System (PVRSS) from manufacturing tolerance to partial shading Module-level voltage shutdown for installer and firefighter safety Flexible system design for maximum space utilization solaredge.com solar Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 P370 P340 P401 (for higher- P400 P405 P485 P505 Optimizer model P320 (for high- power (for 72& (for high (for high- (for high- (for higher (typical module (for 60-cell power 60 and 72- 96 cell power 60 voltage voltage current compatibility) modules) 60-cell and 72 cell modules) cell modules) modules) modules) modules) modules) modules) INPUT Rated Input DC Powero 320 340 370 400 405 485 505 W Absolute Maximum Input Voltage 48 60 80 60 1250 33(2) Vdc (Voc at lowest temperature) MPPT Operating Range 8-48 8-60 8-80 8-60 12.5-105 12.5-83 Vdc Maximum Short Circuit Current11 0.1 4 Adc (Isc) Maximum Efficiency 99.5 Weighted Efficiency 98.8 98.6 Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer ±0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 Material UL94 V-0,UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System 000 Vdc Voltage Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(WxLxH) 129x153x27.5/5.1x6x1.1 29 x153 x33.5 129 x153 x29.5 129x159x49.5/5.1x6.3x1.9 29 x162 x59/ mm /51x6x1.3 /51x6x116 51 x 6.4 x 2.3 /in Weight(including cables) 630/1.4 750/1.7 655/1.5 845/1.9 1064/2.3 gr/lb InputConnector MC41� Single or dual MC40) M C40x4I Input Wire Length 016/0.52 m/ft Output Wire Type/Connector Double Insulated/MC4 Output Wire Length 0.9/2.95 1.2/3.9 m/ft Operating Temperature Rangelu -40-+85/-40-+185 °C/°F Protection Rating IP68/NEMA6P Relative Humidity 0-100 (1)Rated power of the module at STC will not exceed the optimizer"Rated Input DC Power".Modules with up to+5%power tolerance are allowed (2)NEC 2017 requires max input voltage be not more than 80V (3)For other connector types please contact SolarEdge (4)For dual version for parallel connection of two modules use P485-4NMDMRM.In the case of an odd number of PV modules in one string,installing one P485 dual version power optimizer connected to one PV module.When connecting a single module seal the unused input connectors with the supplied pair of seals. (5)For ambient temperature above+85°C/+185°F power de-rating is applied.Refer to Power Optimizers Temperature De-Rating Technical Note for more details. PV System Design Using Single Phase Three Phase for Three Phase for a SolarEdge Inverter(6)(7) HD-Wave Single phase 208V grid 277/480V grid Minimum String Length P ,P01 P370, P440000,P4401 8 10 18 (Power Optimizers) P405,P485,P505 6 8 14 Maximum String Length(Power Optimizers) 25 25 5010 5700(6000 with Maximum Power per String SE7600-US-SE11400- 5250 6000(93 1275010) W US) Parallel Strings of Different Lengths or Orientations Yes (6)For detailed string sizing information refer to:http://www.solaredge.com/sites/default/files/string_sizing_na.pdf (7)It is not allowed to mix P405/P485/P505 with P320/P340/P370/P400/P401 in one string (8)A string with more than 30 optimizers does not meet NEC rapid shutdown requirements;safety voltage will be above the 30V requirement (9)For 208V grid:it is allowed to install up to 7,200W per string when the maximum power difference between each string is 1,000W (10)For 277/480V grid:it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W 0 SolarEdge Technologies Ltd.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc. Ro H S All other trademarks mentioned herein are trademarks of their respective owners.Date:07/2020/V02/ENG NAM.Subject to change without notice. c ll)) Intertek .G NeON®R Black Preliminary LG380Q1K-A6 General Data Electrical Properties(STC*) Cell Properties(MaterialType) Monocrystalline/N-type Model LG3BOQIK-A6 Cell Maker LG Maximum Power(Pmax) [W] 380 Cell Configuration 60 Cells(6 x 10) MPP Voltage(Vmpp) [V] 372 Module Dimensions(Lx W x H) 1,740mm x 1,042mm x 40mm MPP Current(Impp) [A] 1021 Weight 18.5 kg Open Circuit Voltage(Voc,75%) [V] 43.5 Glass(Material) Tempered Glass with AR Coating Short Circuit Current(Isc,75%) [A] 10.85 Backsheet(Color) Black Module Efficiency [%] 21.0 Frame(Material) Anodized Aluminium Power Tolerance [%] 0-+3 Junction Box(Protection Degree) IP 68 with 3 Bypass Diodes *STC(Standard Test Condition):Irradiance 1000 W/m',cell temperature 25°C,AM 1.5 Measure Tolerance:±3% Cables(Length) 1,250mm x 2EA Connector(Type/Maker) MC 4/MC Operating Conditions Operating Temperature* ['C] -40-+85 Certifications and Warranty Maximum System Voltage [V] 1,000 IEC 61215-1/-1-1/2:2016,IEC 61730-1/2:2016, Maximum Series Fuse Rating [A] 20 UL61730-1:2017,UL 61730-2:2017 Certifications" ISO 9001,ISO 14001,ISO 50001 Mechanical Test Load**(Front) [Pa/psf] 5,400 Mechanical Test Load**(Rear) [Pa/psf] 4,000 OHSAS 18001 *The operating ambient temperature of these devices may exceed 40°C at full load for all wire sizes if is Salt Mist Corrosion Test IEC 61701:2012 Severity 6 determined suitable in the field use application. Ammonia Corrosion Test IEC 62716:2013 **Based on IEC 61215-2:2016(Test Load=Design Load x Safety Factor(1.5)) Module Fire Performance Type 2(UL 61730) Fire Rating Class C(UL 790,ULC/ORD C 1703) Packaging Configuration Product Warranty 25 Years Number of Modules per Pallet [EA] 25 Output Warranty of Pmax Linear Warranty* Number of Modules per 40'Container [EA] 650 *Improved:1st year 98.5%,from 2-24th year:0.25%/year down,92.5%at year 25 **In Progress Number of Modules per 53'Container [EA] 850 Packaging Box Dimensions(L x W x H) [mm] 1,790 0 1,120 0 1,227 Temperature Characteristics Packaging Box Dimensions(L x W x H) [in] 70.5o44.1 x 48.3 Packaging Box Gross Weight [kg] 498 NMOT* [ °C] 44±3 Packaging Box Gross Weight [Ib] 1,098 Pmax [%/°C] -0.29 Voc [%/°C] -0.24 Isc [%/°C] 0.04 Dimensions(mm/inch) *N MOT(Nominal Module Operating Temperature):Irradiance 800 W/m',Ambient temperature 20°C, Wind speed 1 m/s,Spectrum AM 1.5 1042.0/41.0(Size of Short Side) Electrical Properties(NMOT) 1002:0/39.4(Distance between Grounding&Mourning Holes) 40.0/157 Model LG380Q1 K-A6 175.0/6.9 r► f- / - J_ Maximum Power(Pmax) [W] 288 16-8.0x 3.0/0.3x 0.1....--.)jP.'" Drain Holes MPP Voltage(Vmpp) [V] 35.1 /0 8-04.3/az MPP Current(Impp) [A] 8.19 Grounding Hole function Box Open Circuit Voltage(Voc) [V] 41.6 8-05012.0/0.300.5° Mourning Holes Short Circuit Current NO [A] 875 1250.0/49.2 .g I-V Curves Cable Length g 12.0- 1000W 10.0 avow 8.0- 600W 7,4 6.0- 1 400W u 4.0- 200W 1, 20- 0.0 ( oo 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 o o • Voltage[1.1] ✓ •' \ - ® LG Electronics USA,Inc. Product specifications are subject to change without notice. LG Solar Business Division LG380Q1 K-A6 pdf 2000 Millbrook Drive 121120 Lincolnshire,IL 60069 Life's Good www.lg-solar.com ©2020 LG Electronics USA,Inc.All rights reserved.