Loading...
HomeMy WebLinkAbout20180079 13.062.3 PeroxyChem_24FreedomWay_ApplPROJECT SITE ADDRESS BUILDING PERMIT SUBMISSION CHECKLIST NEW MULTIPLE -FAMILY RESIDENCE NEW COMMERCIAL BUILDING CHECKLIST PREPARED BY: ZONING DISTRICT PREPARERS PHONE No.: ALL ITEMS BELOW MUST BE CHECKED EITHER "YES", "NO", "N/A", or "PBA" (pending board approval — only where applicable). A separate checklist, must accompany each application for a building permit. All items checked "YES" shall accompany the application form at the time of submission to the building department. Until the application is deemed complete it may be rejected by the building department and returned to the applicant. Acceptance of a permit submission as complete does not imply or guarantee that a permit will be issued. FOR STAFF USE ONLY: SUBMISSION ACCEPTED FOR REVIEW ACCEPTED BY (SIGNATURE) DATE TIME REVISED 4-30-17 YES NO N/A PBA 1. Building permit form completed and with required signatures from the property owner, applicant and contractor. 2. Base fee of $200.00 (per unit) check made payable to Commissioner of Finance. The $.30/sf calculation will be figured during review by the inspector. 3. Water service connection fee agreement dated and signed by the property owner and by a Department of Public Works representative. 4. Energy code compliance report, bearing the seal and signature of the N.Y.S. licensed professional engineer or registered architect. Specify compliance path: 5. Energy code inspection checklist. 6. Septic system permit application form completed and with signatures from the property owner and the contractor. 7. Well completion report and well test results. 7. Site plan approval from Planning Board. 8. Special permit approval from Planning Board. 9. Architectural review approval from: Planning Board Design Review Commission 10. Historic review approval from Design Review Commission. 11. One complete set of building plans, each sheet bearing the seal and signature of the N.Y.S. licensed professional engineer or registered architect. The set shall include, but not be limited to the following drawings: (a) structural plans; (b) floor plans — all levels; (c) cross-sections; (d) details; (e) elevations; (f) schedules; (g) HVAC; (h) electrical; (i) plumbing; (j) codes specifications; (k) fire protection systems; (I) complete code summary 12. In accordance with section 1704 of the Building Code of New York State, a statement of special inspections shall be prepared by the registered design professional, to include: a complete list of materials and work requiring special inspections; the inspections to be performed; and a list of the individuals, approved agencies or firms intended to be retained for conducting such inspections. 13. Other: FOR STAFF USE ONLY: SUBMISSION ACCEPTED FOR REVIEW ACCEPTED BY (SIGNATURE) DATE TIME REVISED 4-30-17 APPLICATION FOR BUILDING PERMIT CITY OF SARATOGA SPRINGS BUILDING DEPARTMENT City Hall- 474 Broadway Saratoga Springs, NY 12866 Telephone (518)587-3550 Ext. 2511 Fax (518)580-9480 KATHLEEN.FARONE@SARATOGA-SPRINGS.ORG For Office Use Only FILE # APPLICATION # ENTERED DATE PERMIT # ISSUED DATE COMMERCIAL NEW APPLICATION FEE PAID $ INS Job Site Zoning Information Zoning District Sect-Blk-Lot Lot Width Lot Area No. of Bedrooms 1st Floor Area No. of Stories 2nd Floor Area Bldg. Height Basement Area Yard Dimensions for Principal Building Front Rear Left Right Accessory Building — Distance To Principal Building Left lot line Rear lot line Right lot line Property Owner: Address Applicant Address Phone Phone Email Email Signature Signature CID# CID # Contractor Address Design Professional Address Phone Phone Fax Fax Email Email Signature CID# CID # 1 ADDRESS/LOCATION *Please note that all applications granted approval by the Design Review Commission and/or the Zoning Board of Appeals shall expire within eighteen months unless a building permit is issued and actual construction has begun (section 240-7.12) Application is hereby made to the Building Department for the issuance of a building permit for construction as herein described, pursuant to provisions of the Zoning Ordinance of the City of Saratoga Springs and in accordance with the N.Y. State Uniform Fire Prevention and Building Code which is applicable to new construction of buildings, and to conversions, additions and alterations to buildings. The owner and the applicant agree to comply with all applicable laws, ordinances and regulations and with all regulations and procedures as explained in this application, and will allow all inspectors to enter the premises for all required and necessary inspections. The following regulations shall apply: A. This application shall be completed and signed by the property owner and the applicant, and submitted to the Building Department. B. This application must be accompanied by: 1. Plot plan showing lot dimensions, existing and proposed buildings or structures on the lot and their distances to one another as well as to the lot lines, and all other pertinent details of the property. A copy of a legal survey is required for all new construction and may be required at the discretion of the building inspector for all projects as deemed necessary. 2. One complete set of plans and specifications for the proposed construction, each plan bearing the signature and seal of a New York State Registered architect or licensed professional engineer, (exception: projects where no structural work is necessary and expenditures are minor, in accordance with the State Education Law). For all new construction completed checklists shall be submitted (see attached). C. Insurance requirements: • Contractor must provide: (a) certificate of liability insurance showing a one million dollars per occurrence and two million dollars aggregate, with the City of Saratoga Springs listed as additional insured and certificate holder; (b) certificate of workers compensation insurance, on either the State approved C-105.2 form or the U-26.3 form; (c) certificate of disability insurance, on either the State approved DB -120.1 or DB -155 form; (d) If needed, Form CE -200 for WC/DB exemption is found at www.wcb.ny.gov. D. Application fee as required by the City Code and as calculated by the building department, shall be paid by check or money order (payable to "Commissioner of Finance".) Work covered by this application shall not commence prior to permit issuance. E. Occupancy of any building or premises to which this application applies shall not occur prior to the issuance of a required Certificate of Occupancy. F. Any deviation from approved plans must be authorized by the approval of revised plans subject to the same procedure established for the examination of the original plans by the building department, including any required fees. G. Building Department shall be notified (minimum notice — 24 hours in advance) according to this required schedule of inspections. (Note; before subsequent inspection requests will be scheduled, all prior inspections shall have passed). See attached card for required inspections included with building permit when issued. H. The building permit is effective for two years from the date of issuance unless a different period of time is specified. 2 ADDRESS/LOCATION Is the job site in a floodplain? Is this job site in a historic district? If so, DRC approval date Is this job site in a architectural district? If so, date of approval Does application require approval ZBA approval? If so, date of approval Does application require the city planning board approval? If so, date of approval (Ex: site plan, subdivision, special permit) Construction Costs Basic Improvement $ Electrical $ Heating $ Other $ Total Cost $ PLEASE PROVIDE A BREIF DESCRIPTION OF WHAT THE SCOPE OF WORK IS TO BE DONE: HOLD HARMLESS: The Individual filing this application, to the fullest extent provided by law, shall indemnify and save harmless the City of Saratoga Springs, its Agents and Employees (hereinafter referred to as "City"), from and against all claims, damages, losses and expense (including, but not limited to, attorneys' fees), arising out of or resulting from the performance of the work covered by this building permit application, sustained by any person or persons, provided that any such claim, damage, loss or expense is attributable to bodily injury, sickness, disease, or death, or to injury to or destruction of property caused by the tortious act or negligent act or omission of Applicant, its contractor or its employees or anyone for whom the Contractor is legally liable or Subcontractors. INITIAL 3 DUPONT BUILDING, INC. FIBERGLASS BUILDINGS WOMAN OWNED CERTIFICATION # CSW7939 COMMUNICATION SHELTERS ISO 9001:2008 CERTIFICATION # FM637534 100 RITA DRIVE STEEL BUILDINGS BELL CITY, LOUISIANA 70630 OFFSHORE STRUCTURES 337-905-5928 www.dupontbuilding.com FAX: 337-905-5268 kfregia@dupontbuilding.com CUSTOMER: Parsons PROJECT: PDC - UPS System DATE: November 3, 2017 ADDRESS: 100 High Street Phone: 617-449-1235 City,State: Boston MA ATTENTION: Willey Leung Email: willey.leung@parsons.com PROPOSAL: 17311C DESCRIPTION AMOUNT 1 ELECTRICAL EQUIPMENT ENCLOSURE Steel Construction 8 ft. Wide X 10 ft. Long X 9 ft. High I $45,594.00 I SHELTER INCLUDES: Galvanneal Steel Panel Exterior Finish 125 mph Wind Load 60 Ib Roof Load Ceiling Insulation 3 1/2" Sprayed in, High Density, closed cell foam (R-22) Wall Insulation 3" R -MAX (R-19.9) Floor Insulation 4" Sprayed in, closed cell (R-24) Shelter Weight 10,000 lbs (estimated w/o customer equipment) STRUCTURAL STEEL SKID is constructed of C8x115 perimeter Channel and C6x8.2 Cross supports. SKID is hot dip galvanized after fabrication. FLOOR is constructed of 1/4" SMOOTH STEEL PLATE WELDED TO CROSS MEMBERS OF SKID BEAM FROM UNDERNEATH WITH NO WELDS SHOWING. FLOOR TO BE PAINTED GREY EPDXY WITH SLIP RESISTANT TEXTURE WALLS ARE 14 GAUGE GALVANNEAL STEEL INTERLOCKING PANELS FULLY INSULATED BETWEEN RIBS. EXTERIOR WALLS TO BE PRIMED AND PAINTED AFTER CONSTRUCTION. ROOF IS FABRICATED FROM 12 GAUGE GALVANNEAL STEEL PANELS AND WILL BE INTERLOCKING AND WILL BE PRIMED AND PAINTED AFTER FABRICATION. CEILING and INTERIOR WALLS shall be 14 gauge smooth GALVANNEAL steel panels painted white. ALL WIRING MEET THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE ENGINEERED DRAWINGS AND THIRD PARTY INSPECTIONS PER CUSTOMER APPROVED DRAWINGS INSTALLED OR PROVIDED EQUIPMENT Quantity Part # Description SHELTER ENTRANCE 3X7 PLC12LSJ2-3SF-PW H/L. 16GA GALVANIZED STEEL JOINER DOOR AND 12GA FRAME 3'X7', 3 SIDED FRAME WITH NO THRESHOLD, HINGE LEFT, (3) 4-1/2" X 4-1/2" STAINLESS STEEL HINGE, 1-1/2" ROCKWOOL INSULATION, PRECISION FL2108X4914A US32D PANIC 1 9728 BAR, LCN 4116 H/CUSH DOOR CLOSER, 12"X12" LITE 1/4" WIRE GLASS, ALUMINUM SPLIT JAMB FRAME JMM-952 FOR 2-3/4" WALL. DRILL 5/16" HOLES 1" FROM EDGE OF FRAME TO CENTER OF HOLES. 5 HOLES ON TOP AND 7 HOLES ON SIDES. DOOR AND FRAME TO BE PAINTED WHITE. EXACT FRAME SIZE 3' - 1-1/2" X 7-1-3/4". CUT OUT IN STEEL 3'-2-1/2"X7'-2- 1/4". D-JDGS-278 1 8318-16 STEEL DOOR SHIELD 24" X 46" X 6" - 16 GAUGE PAINTED 1 5906 NAME AND DATA PLATE FOR DOORS ELECTRICAL BUILDING LIGHTING PANEL 1 LP-1 EATON PANELBOARD, 120/240V, 80A MAIN BREAKER, 30 CIRCUITS 480V PANELS 1 PP-1 EATON PANELBOARD, 480V, 18 CIRCUITS, 125A MAIN BREAKER, 14KAIC (LINE SIDE) 1 PP-2 EATON PANELBOARD, 480V, 18 CIRCUITS, 125A MAIN BREAKER, 14KAIC (UPS LOAD SIDE) TRANSFORMER 1 XFMR-1 EATON TRANSFORMER-15 KVA, 480-120/240, 60HZ SURGE PROTECTION 1 7202 ERICO SURGE PROTECTION SES40 - 120/240 SURGE PROTECTION, NO ALARM INTERIOR LIGHTING 1 7717 SINGLE WALL SWITCH WHITE 20A, 120/277V- CS120W 3 8778 LITHONIA LBL4 LP840 4' LED WRAPAROUND MVOLT 4,000k @ 4,600 LUMENS INTERIOR RECEPTACLES 2 7482 HUB CR20-WHI WHT DPLX RECT 20A, NEMA 5-20R HVAC 1 7548-NPN BARD 3-1/2 TON 230/1PH, 10KW, PLEATED FILTER, 10 EER, W42AA-A1OXP5XXJ 1 1961 SUPPLY GRILL, 28X8 BARD VH (3-TON) 1 1966 RETURN GRILL 28X14 BARD RCBF RAFG (3-TON) RH45 1 1975 THERMOSTAT HONEYWELL MISC 1 9949 GENTEX 9123TF SMOKE DETECTOR 15 7573 1/8" SHIM PLATES 15 7574 1/4" SHIM PLATES * * BLANK BULKHEAD PLATES FOR FIELD PENETRATIONS NOTES RECEIVE AND INSTALL CUSTOMER PROVIDED UPS ALL OTHER EQUPIMENT SHALL BE PROVIDED AND INSTALLED ON SITE BY OTHERS REV A NOTES REMOVED EMERGECY LIGHTING, EXTERIOR RECEPTACLES AND LIGHTING CORRECTED TEXT ERROR IN PROPOSAL REV B NOTES CHANGED DIMENSIONS TO 8X10 INCLUDED (2) 480V PANELS, XFMR, AND 120/240 PANEL REV C NOTES REVISED 480V AND LIGHTING PANELS (SEE ATTACHED BOM) REVISED TRANSFORMER TO 15KVA DELIVERY TO: Saratoga Springs, NY Delivery in 1 Loads Total 1 $11,871.00 DELIVERY DOES NOT INCLUDE OFFLOAD AT SITE UNLESS SPECIFICALLY CONTRACTED FOR. SEE PLANS FOR LIFT DETAIL AND OFFLOAD RECOMMENDATIONS. DELIVERY ALSO DOES NOT INCLUDE ANY SAFETY TRAINING TIME REQUIRED TO DELIVER SHELTER TO SITE. ANY HOLDOVER TIME FOR SAFTEY TRAINING WILL BE BILLED AT $75.00 PER HOUR. DELIVERY COST IS ESTIMATED AND MAY VARY BASED ON FUEL COST AT TIME OF DELIVERY AND DESIGN ISSUES THAT CAN ALTER THE WIDTH OF THE LOAD, AND SITE ACCESS ISSUES. PRICE DOES NOT INCLUDE ANY APPLICABLE SALES TAXES. SALES TAXES AS REQUIRED WILL BE ADDED TO INVOICE AND WILL BE THE RESPONSIBILITY OF CUSTOMER. DELIVERY IS BASED ON BEING ABLE TO ACCESS SITE WITH NORMAL TRACTOR TRAILER, ANY ROAD CONDITONS THAT PROHIBIT BEING ABLE TO ACCESS WITH TRACTOR TRAILER WILL REQUIRE ADDITIONAL COST BASED ON SITE CONDTIONS AND WILL BE CHARGED TO CUSTOMER DELIVERY DATE STATED BELOW IS BASED ON CURRENT FACTORY LOAD AND VENDOR SCHEDULES WHICH 15 SUBJECT TO CHANGE. TERMS: NET 30 DAYS. BUILDING WILL BE INVOICED 10 DAYS AFTER COMPLETION PAYMENT BY CREDIT CARD WILL BE ASSESSED A PROCESSING FEE OF 4%. PAYMENTS IN EXCESS OF 30 DAYS DELINQUENT WILL BE CHARGED 1.5% MONTHLY FINANCE CHARGE BUILDING MAY BE STORED AT DUPONT FOR UP TO 30 DAYS WITHOUT INCURRING STORAGE CHARGES. FOB: SITE DEL. DATE: 10-12 WEEKS AFTER APPROVED DRAWINGS TOTAL: $57,465.00 All materials and procedures are guaranteed to be as written. Changes from the said specifications involving extra costs will be made only by written orders, and will be added to said price. Buildings are warranted for 5 year against manufactures defects. Any items not manufactured by Dupont Building, Inc. shall bear the warranty of the respective manufacturer. All taxes applicable to the sale of above to be incurred by purchaser. This proposal may be withdrawn by us if not accepted within 60 days. AUTHORIZED SIGNATURE KRISTOPHER L. FREGIA DUPONT BUILDING, INC. BELL CITY, LA 337-905-5928 E,T.N Detail Bill of Material 'age 1 of 1 INI Project Name: Peroxychem — UPS System for Clean Negotiation No: RAZ80726X7K1 Powerrtj 8usirtess Worldwide Room Instrumentation General Order Alternate No: 0000 No: Item No. Qty Product Description 1 93PM UPS 20-200kW 480V in, 480V out (3 wire) System Voltage, 60kW Rated, 100kW Frame Capacity, Standard 97% Efficiency, Firmware expandable to 100kW, Includes PowerXpert Gateway Card, Industnal Relay Card, and EMP, 26 minutes of runtime at 60 kW, Includes 7x24 Startup, and 1 year on-site parts and labor coverage, Includes 1 year PredictPulse monitoring Qty List of Materials 1 93PM UPS 480V in, 480V out (3 wire)100kW UPS Frame Dimensions: 30"W x 42"D x 74"H, Weight: 1107 lbs. Heat Rejection: 7164 BTU/Hr 1 93PM IBC -L Battery Cabinet, 1/1 Strings/Cabinets Dimensions: 32"W x 42"D x 74"H, Weight: 3795 lbs 1 Standard Ground Shipping to NY 1 FOB Destination 1St Destination Budgetary Price: $48,708.00 Net total This BOM is meant for indoor use only. This is not an outdoor solution. Eaton PQ terms and conditions applies. M orders must be released for manufacture within 90 clays of date of order entry. If approval drawings are required, drawings must be retumed approved for release within 60 days of mailing. If drawings are not returned accordingly, and/or if shipment is delayed for any reason, the price of the order will increase by 1.0% per month or fraction there of for the time the shipment is delayed. General Information: 93PM UPS 20-200kW 93PM System Specifications System Voltage: 480V in, 480V out (3 wire) UPS Frame Capacity: 100kW Quantity of 50kW Power Modules: 2 UPS kW Rating: 60 Internal Redundant Configuration: No Interal Battery Configuration: None Input Feed: Single Feed ESS Included: No Communication: Power Xpert Gateway Card, Accessories: Sidecar Bypass Cabinet Industrial Relay Card, and EMP Side Car: 3 Breaker MBS, Left Mount Side Car Breaker Rating: 35kAIC MBS w/ Aux contact Exhaust Configration: Top Air Exhaust Internal Runtime: None UPS Dimensions (H" x W" x D"): 74 x 30 x 42 UPS Weight (lbs): 1107 93PM Battery Cabinet 9PZABAE39010000 Battery Cabinet: IBC -L DC Voltage: 432 Battery Cabinet Weight (lbs): 3795 Battery Cabinet Width (in): 32.3 74" H x 42" D kW for Runtime Calculation: 60 Runtime (min): 26 # of Cabintes/Strings: 1/1 Battery Manufacturer: Eaton Battery Installation: Line and match OSHPD Rated: No UPS System Dimensions Combined Matching System Dimensions (H" x W" x D", excluding non- 74 x 62.3 x 42 matching panels): UPS Accessories Floor Stand: None Chimney: None The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. PREPARED BY DATE RICH SU 7/26/2017 Eaton APPROVED BY DATE JOB NAME Peroxychem — UPS System for Clean Room Instrumentatior DESIGNATION VERSION 10.0.0.0 TYPE 93PM UPS 20-200kW DRAWING TYPE CustomerAppr. NEG -ALT Number RAZ80726X7K1-0000 REVISION 0 DWG SIZE A G.O. ITEM SHEET 1 of 2 ... w _ a __.,... 1 2 Structure 1 2 Ship-Inches Ship-MM Width-Inches Width-MM 32.00 812 30.00 762 Depth-Inches Depth-MM 42.00 1066 42.00 1066 Height-Inches Height-MM 74.00 1879 74.00 1879 Weight-Lbs Weight-Kg 3795.00 8367.98 1107.00 2440.94 The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. PREPARED BY DATE RICH SU 7/26/2017 Eaton APPROVED BY DATE JOB NAME Peroxychem — UPS System for Clean Room Instrumentatior DESIGNATION VERSION 10.0.0.0 TYPE 93PM UPS 20-200kW DRAWING TYPE CustomerAppr. NEC-ALT Number RAZ80726X7K1-0000 REVISION 0 DWG SIZE A G.O. ITEM SHEET 2 of 2 A B C D E F G H K L M 3 4 5 61 7 81 9 10 1 11 1$ 13 114 15 965.5 [38.0] 451 TOP VIEW (TOP EXHAUST OPTION) 524 [20.6] [17.8] 500 [19.7] TOP WIRE ENTRY 21,5 [•8] 160 [6.3] "ZONE -1" 224 [8 8] "ZONE -2" 356 [14.0] "ZONE -3" 441 [17.4] TOP ENTRY CONTROL WIRING CONDUIT PLATE N 12 [.5] 541 [21.3] 88 [3.5] (2X) FRONT VIEW (SIDE CAR CAN BE ON LEFT OR RIGHT SIDE) [74] DOOR VENTILATION AREA 46 [1.8] 178 (7") COLOR DISPLAY 6,5 [.3] DISPLAY TOP VIEW (REAR EXHAUST OPTION) 30 [1.2] DETAIL E SIDE VIEW f 1067 [42.0] -ORA AR/I- INTER CABINET WIRING ACCESS (BOTH SIDES) s INTER -CABINET WIRING ACCESS (BOTH SIDES) 0 M10 THD (8X) 4 EACH SIDE _ ° + + 16 BOTTOM VIEW 471,5 [18.6] SEE DETAIL E 480 [18.9] 176 [6.9] 4,3 [.2] HDWR 47,4 [1.9] 960[37.8] 58[2.3] f 388[15.3] 630[24.8] 140 [5.5] 31,5 [1.2] BACK VIEW (TOP EXHAUST OPTION) 976 [38.4] BOTTOM WIRE ENTRY 11 O MBTHD (12X) 6 EA FRT & REAR OrE E1 0,21 I- 38,5 [1 5] BACK VIEW (REAR EXHAUST OPTION) ■fififififi•••••• ■fififififi•••••• ■fififififi•••••• ■fififififi•••••• ■tititititi•••••• ■fifififififif !" fifififififi•••••• ■fififififi•••••• mmiommrnmm ■tititititi•••••• ■tititititi•••••• ■tititititi•••••• ■tititititi•••••• 1•••••••• ••• ■tititititi•••••• ■tititititi•••••• ■tititititi•••••• ■tititititi•••••• ■tititititi••••.. ■tititititi•••••• ■II••titi•••••• ■II••fifi•••••• 30[1.2] 67,5[2.7] 395[15.6] 542[21.3] 646[25.4] v WEIGHT AND CENTER OF GRAVITY RAZ80726X7K1-0000-7/26/2017 DIMENSIONS MM (IN) Job Name: WEIGHT kg [lbs] Item Number: A 9PG06D0009E2OR2 B C UPS W/ LEFT SIDECAR (4 BKR) 100KW CAPACITY FRAME- 1 50KW UPM INSTALLED W/ LEFT SIDECAR (4 BKR) 855 [33.7] 568 [22.4] 390 [15.4] 433 [954] 100KW CAPACITY FRAME- 2 50KW UPM INSTALLED W/ LEFT SIDECAR (4 BKR) 917 [36.1] 564 [22.2] 402 [15.8] 496 [1094] 100KW REDUNDANT FRAME- 1 SOKW UPM INSTALLED W/ LEFT SIDECAR (4 BKR) 858 [33.8] 568 [22.4] 391 [15.4] 439 [967] 100KW REDUNDANT FRAME- 2 50KW UPM INSTALLED W/ LEFT SIDECAR (4 BKR) 918 [36.1] 564 [22.2] 403 [15.9] 502 [1107] 100KW REDUNDANT FRAME- 3 50KW UPM INSTALLED W/ LEFT SIDECAR (4 BKR) 1001 [39.4] 561 [22.1] 412 [16.2] 566 [1248] UPS W/ RIGHT SIDECAR (4 BKR) 100KW CAPACITY FRAME- 1 50KW UPM INSTALLED W/ RIGHT SIDECAR (4 BKR) 855 [33.7] 568 [22.4] 367 [14.4] 433 [954] 100KW CAPACITY FRAME- 2 50KW UPM INSTALLED W/ RIGHT SIDECAR (4 BKR) 917 [36.1] 564 [22.2] 356 [14.0] 496 [1094] 100KW REDUNDANT FRAME- 1 50KW UPM INSTALLED W/ RIGHT SIDECAR (4 BKR) 858 [33.8] 568 [22.4] 366 [14.4] 439 [967] 100KW REDUNDANT FRAME- 2 50KW UPM INSTALLED W/ RIGHT SIDECAR (4 BKR) 918 [36.1] 564 [22.2] 355 [14.0] 502 [1107] 100KW REDUNDANT FRAME- 3 50KW UPM INSTALLED W/ RIGHT SIDECAR (4 BKR) 1001 [39.4] 561 [22.1] 346 [13.6] 566 [1248] UPS W/ LEFT EMPTY SIDECAR (TOP ENTRY) 100KW CAPACITY FRAME- 1 50KW UPM INSTALLED W/ LEFT EMPTY SIDECAR FOR TOP ENTRY 844 [33.2] 542 [21.3] 409 [16.1] 406 [894] 100KW CAPACITY FRAME- 2 50KW UPM INSTALLED W/ LEFT EMPTY SIDECAR FOR TOP ENTRY 911 [35.8] 541 [21.3] 419 [16.5] 469 [1034] 100KW REDUNDANT FRAME- 1 50KW UPM INSTALLED W/ LEFT EMPTY SIDECAR FOR TOP ENTRY 847 [33.3] 542 [21.3] 410 [16.1] 411 [907] 100KW REDUNDANT FRAME- 2 50KW UPM INSTALLED W/ LEFT EMPTY SIDECAR FOR TOP ENTRY 913 [35.9] 541 [21.3] 420 [16.5] 475 [1047] 100KW REDUNDANT FRAME- 3 50KW UPM INSTALLED W/ LEFT EMPTY SIDECAR FOR TOP ENTRY 1001 [39.4] 541 [21.3] 427 [16.8] 539 [1188] UPS W/ LEFT EMPTY SIDECAR (TOP ENTRY) 100KW CAPACITY FRAME- 1 50KW UPM INSTALLED W/ RIGHT EMPTY SIDECAR FOR TOP ENTRY 844 [33.2] 542 [21.3] 347 [13.7] 406 [894] 100KW CAPACITY FRAME- 2 50KW UPM INSTALLED W/ RIGHT EMPTY SIDECAR FOR TOP ENTRY 911 [35.8] 541 [21.3] 338 [13.3] 469 [1034] 100KW REDUNDANT FRAME- 1 50KW UPM INSTALLED W/ RIGHT EMPTY SIDECAR FOR TOP ENTRY 847 [33.3] 542 [21.3] 346 [13.6] 411 [907] 100KW REDUNDANT FRAME- 2 50KW UPM INSTALLED W/ RIGHT EMPTY SIDECAR FOR TOP ENTRY 913 [35.9] 541 [21.3] 337 [13.3] 475 [1047] 100KW REDUNDANT FRAME- 3 50KW UPM INSTALLED W/ RIGHT EMPTY SIDECAR FOR TOP ENTRY 1001 [39.4] 541 [21.3] 330 [13.0] 539 [1188] NOTES: 1. THE SYSTEM MUST BE INSTALLED ON A LEVEL FLOOR SURFACE SUITABLE FOR COMPUTER OR ELECTRONIC EQUIPMENT. 2. UPS WITH SIDECAR COMES WITH REMOVABLE TOP AND BOTTOM ENTRY CONDUIT LANDING PLATE. 3. CONTROL WIRE ENTRY THROUGH REMOVABLE CONTROL LANDING PLATE. 4. THE SYSTEM MUST BE INSTALLED IN A TEMPERATURE AND HUMIDITY CONTROLLED INDOOR AREA FREE OF CONDUCTIVE CONTAMINANTS. 5. AMBIENT TEMPERATURE RANGE 5-40degC [41-104degF] AT AN ELEVATION UP TO 1500M WITHOUT DERATING.STORAGE TEMPERATURE -25 to +55degC. RELATIVE HUMIDITY(OPERATING AND STORAGE) 5% TO 95% MAX NON CONDENSING. 6. UPS WITH SIDECAR CABINET CLEARANCES: FRONT OF THE CABINET: 914mm[36.0"] FROM TOP OF THE CABINET: 457mm[18.0"] ALWAYS IN ZONE -1 AND ZONE -3 ZONE -2 CAN BE LESS THAN 457mm[18.0"] WITH REAR SERVICE ACCESS FROM BACK OF THE CABINET WITH REAR EXHAUST: 254mm[10.0"] 7. MINIMUM REQUIRED AIR FLOW FOR CABINET AT FULL LOAD IS 800 CFM. 8. THE UPS WITH SIDECAR CABINET CAN BE INSTALLED IN LINE -UP -AND -MATCH OR STANDALONE CONFIGURATIONS. 9. ALL WIRING IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRIC CODES. 10. WEIGHT OF THE CABINET DOES NOT INCLUDE CUSTOMER WIRING. 11. UPS WITH TOP ENTRY SIDECAR AC INPUT TO UPS RECTIFIER: 3 PHASES, GROUND,WYE. AC OUTPUT TO LOAD: 3 PHASES,GROUND. AC INPUT TO UPS BYPASS: 3 PHASES,GROUND,WYE. DC INPUT TO UPS(EXTERNAL BATTERY ONLY): POSITIVE,NEGATIVE,GROUND. 12. SOURCE INPUT TO BYPASS CABINET: 3 PHASES, GROUND,WYE. AC OUTPUT TO LOAD: 3 PHASES,GROUND. 13. SPECIFICATIONS ARE SUBJECT TO CHANGE. METRIC r" EATON CORPORATION E_T•N DESCRIPTION: 93PM-100 FRAME WITH SIDECAR UPS SITE PLAN ORIGINATED RANDEV A PPOLT2012 ECO. ECO -054280 NAME P-110000128 PRO -E DRAWING Apppoyw • A B C D E F G H K �v1 3 4 5 61 7 81 9 12 13 114 15 Go/NEG-Alt-Date: RAZ80726X7K1-0000-7/26/2017 Job Name: Peroxychem - UPS System for Clean Room Instrumentation Item Number: Catalog Number: 9PG06D0009E2OR2 Designation: A B c D E F G H K L M 3 4 5 61 7 81 9 10 1 11 1a 13 14 15 N z O y z O 0) CUSTOMER CONTROL WIRE CONNECTIONS U 0 I- r I- I- I- NNV VMMINIt- 111111 222222222 aaaaaaaaao FNM V NCOh NAS CUSTOMER INPUT ALARMS DETAIL A O LLJmJI JJ MI mm 0000 U0 A- NM V ,-N NMO NNI�M O. CUSTOMER CAN O m 0 m RS232 m0 alb ma 0l l w0ww NMI' EPO 7 7 001010 ZZU FNM RELAY OUTPUT _ O MINI SLOT COMMUNICATION BAYS SEE DETAIL C INPUT TERMINAL BLOCK (SOURCE 2) DETAIL B FRONT VIEW W/O DOOR W/O UPS LOWER DEADFRONT W/O SAIC-B DEADFRONT (4 BREAKER VERSION SHOWN) RIB BREAKER (SOURCE 1) BIB BREAKER MAINTENANCE BYPASS BREAKER MAINTENANCE ISOLATION BREAKER OUTPUT TERMINAL BLOCK E6/E7/E8 AC INPUT TO BYPASS E1/E2/E3 AC INPUT TO UPS RECTIFIER 3 7,177.7 . III fHH, .I •r SIAC-B 4 • • rt Q SsS 9.1 • - r® UPS GROUND TERMINALS • vu SEE DETAIL B INTERFACE TERMINALS SEE DETAIL A 61 7 50KW POWER MODULE QTY 1 OR 2 FOR CAPACITY SYSTEM QTY 1, 2, OR 3 FOR REDUNDANT SYSTEM BATTERY START SERVICE BYPASS SWITCH SEE DETAIL D SHUNT TRIP BATTERY INPUT (+) E4 BATTERY INPUT (-) E5 E9/E10/E11 AC OUTPUT TO LOAD 81 9 10 11 DETAIL C DETAIL D 13 1 PULL CHN 2 GND_S 3 CANBH 4 CANBL 5 GND(ISP) 6 EARTH / 7 CANBH \ 8 CANBL 9 GND(ISP) 10 EARTH / a U- CL a03 am a ~ a U0 a 0 a0° 16 48Vdc BATTERY SHUNT TRIP - 48Vdc BATTERY SHUNT TRIP + 14 1 PRODUCT SPECIFICATIONS UPS RATING AC INPUT VOLTAGE AC OUTPUT VOLTAGE AC INPUT/ BYPASS CURRENT AC OUTPUT CURRENT MAX HEAT DISSIPATION AT 100% LOAD DC INPUT VOLTAGE DC INPUT CURRENT KVA KW V V AMP AMP KW [BTU/HR] V AMP 20 20 480 480 35 24 0.75 [2550] 432 50 30 30 48 36 1.05 [3580] 74 40 40 60 48 1.34 [4560] 99 50 50 73 60 1.67[5700] 124 60 60 94 72 2.10[7164] 149 70 70 108 84 2.45[8358] 174 80 80 120 96 2.67[9121] 198 90 90 133 108 3.01 [10261] 223 100 100 146 120 3.34 [11402] 247 CUSTOMER WIRING (UPS) WIRES ACCEPTED WIRE RANGE TORQUE RATING N*M [LB.IN] RECOMMENDED MINIMUM WIRE SIZE FOR 75 DEG C COPPER STRANDED WIRE (WIRE SIZES ARE FOR 100KW) INPUT PHASE WIRES (2)6 AWG-250MCM 31 [275] (1)4/0 BYPASS PHASE WIRES (2) 6 AWG-250MCM (1)4/0 OUTPUT PHASE WIRES (2) 6 AWG-250MCM (1) 2/0 DC INPUT FROM BATTERY (4) 6 AWG-250MCM (2) 3/0 GROUND WIRES (INPUT, BYPASS, AND OUTPUT) (6) 14 AWG -1/0 8 AWG 4.5 [40] (1) 6 AWG 4 AWG -6 AWG 5.1 [45] 3 AWG -1/0 5.6 [50] GROUND WIRES(BATTERY) (6) 14 AWG -1/0 8 AWG 4.5 [40] (1) 4 AWG 4 AWG -6 AWG 5.1 [45] 3 AWG -1/0 5.6 [50] CONTROL WIRE (DETAIL C) 12-22 AWG 0.56-0.79 [5-7] CONTROL WIRE (DETAIL B,D) 14-30 AWG 0.22-0.25 [2] CUSTOMER WIRING (SIAC-B 4 BREAKER CONFIGURATION) WIRES ACCEPTED WIRE RANGE TORQUE RATING N*M [LB.IN] RECOMMENDED MINIMUM WIRE SIZE FOR 75 DEG C COPPER STRANDED WIRE (WIRE SIZES ARE FOR 100KW) INPUT PHASE WIRES (RECTIFIER INPUT BREAKER) (1) 4AWG-350MCM 19.9 [177] (1)4/0 BYPASS AC INPUT (TERMINAL BLOCK) (1) 6AWG-300MCM 31.0 [275] (1) 4/0 OUTPUT PHASE WIRES (TERMINAL BLOCK) (1) 6AWG-300MCM 31.0 [275] (1) 2/0 GROUND WIRE 14 AWG -1/0 5.1 [45] 6 AWG METRICT±120,EATON CORPORATION E:T•N DESCRIPTION: 93PM-100 FRAME WITH SIDECAR UPS SITE PLAN ONNPAMTRANDEV A 2800T2012 ECO: EGO -058280 NAME: REVISION: 008 SISE: STATE: RELEASE 0.087 DOCUMENT TYPE PRO -E DRAINING P-110000128 A B c D E F G H K Go/NEG-Alt-Date: RAZ80726X7K1-0000-7/26/2017 Job Name: Peroxychem — UPS System for Clean Room Instrumentation Item Number: Catalog Number: 9PG06D0009E2OR2 Designation: A B C D E F G H K M 1 3 4 5 61 7 81 9 101 11 12 13 114 15 16 3 4 5 61 7 8I 9 AC INPUT TO RECTIFIER (SOURCE 1) AC INPUT TO BYPASS (SOURCE 2) V UPS CABINET UPM 1 UPM 2 UPM 3 FUSE RECTIFIER SWITCHGEAR RECTIFIER E1,E2,E3 INVERTER • INVERTER SWITCHGEAR FUSE FUSE RECTIFIER SWITCHGEAR RECTIFIER INVERTER INVERTER SWITCHGEAR FUSE FUSE RECTIFIER SWITCHGEAR RECTIFIER INVERTER INVERTER SWITCHGEAR FUSE OPTIONAL SINGLE -FEED 1 JUMPER E6,E7,E8 FUSE BYPASSS SWITCHGEAR STATIC SWITCH Y F (2, 3, OR 4-BKR) BYPASS CABINET RECTIFIER INPUT BREAKER • E6, E7, E8 BYPASS INPUT BREAKER MAINTENANCE BYPASS BREAKER BATTERY CONVERTER BATTERY SWITCHGEAR FUSE BATTERY CONVERTER — BATTERY SWITCHGEAR FUSE BATTERY CONVERTER BATTERY SWITCHGEAR FUSE E4,E5 E9,E1 0,E1 1 n • 6-0 MAINTENANCE ISOLATION BREAKER E9. E10, Ell 10 I 11 14 13 14 1 \I BATTERY BREAKER EXTERNAL BATTERY CABINET NOTE: AC INPUT TO RECTIFIER IS NOT USED IN SINGLE FEED CONFIGURATION. DASHED LINES INDICATE OPTIONAL FEATURES/COMPONENTS. AC OUTPUT TO LOAD METRICT±11EATON CORPORATION E:T•N DESCRIPTION: 93PM-100 FRAME WITH SIDECAR UPS SITE PLAN oRi•avrEIRANDEV A 2800T2012 ECO: EGO -054280 NAME1 REVISION: 008 SIZE: Al PEEWEE WALLACE T 11SEP2013 SCALE: DOCUMENT TYPE STATE: RELEASE 0.0457 CHECKED WEED APPROVED P-110000128 A B D E F G H K GO/NEG-Alt-Date: RAZ80726X7K1-0000-7/26/2017 Job Name: Peroxychem — UPS System for Clean Room Instrumentation Item Number: Catalog Number: 9PG06D0009E2OR2 Designation: H G F E D C B A 8 7 6 5 4 3 2 TOP VIEW TOP EXHAUST CONFIGURATION 729 [287] 11 11 1 11 11 11 FRONT VIEW A22 (0.81TOP VENTILATION A 2210.81 0 x 819 [32.3] 14915.9] 811 32.0] NOTES 1. THE SYSTEM MUST BE INSTALLED ON A LEVEL FLOOR SURFACE SUITABLE FOR COMPUTER OR ELECTRONIC EQUIPMENT. 2. THE SYSTEM MUST BE INSTALLED IN A TEMPERATURE AND HUMIDITY CONTROLLED INDOOR AREA FREE OF CONDUCTIVE CONTAMINANTS. 3. AMBIENT TEMPERATURE RANGE 5-40degC [41-104de9F] RECOMMENDED OPERATING RANGE: 20-25degC [68-77degF] RELATIVE HUMIDITY: 5%-95% NON -CONDENSING. 4. WEIGHT: SEE TABLE, SOME OPTIONS WILL WEIGH LESS. WEIGHTS DO NOT INCLUDE CUSTOMER WIRING. 5. MINIMUM 914mm [36"] FRONT ACCESS NEEDED FOR SERVICING. 6. VENTILATION IS BY MEANS OF NATURAL CONVECTION AND CAN BE CONFIGURED FOR TOP OR REAR. MINIMUM 203mm [8"] CLEARANCE IN REAR IS NEEDED FOR REAR VENTILATION, OR MINIMUM OF 203mm [8'] CLEARANCE ON TOP IS NEEDED FOR TOP VENTILATION. 7. THE UPS BATTERY CABINET CAN BE INSTALLED IN LINE -UP -AND -MATCH OR STANDALONE CONFIGURATIONS. 8. BOTTOM CABLE ENTRY THROUGH REMOVABLE CONDUIT LANDING PLATE. TOP CABLE ENTRY THROUGH OPTIONAL SIDE CAR WITH REMOVABLE CONDUIT LANDING PLATE. FOR IBC -L WITH TOP -ENTRY SIDE CAR SEE P-110000131. 9. ALL WIRING I5 TO BE IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRIC CODES. 10. POWER HOOKUP TO UPS: POSITIVE, NEGATIVE, GROUND. FOR LINE -UP -AND -MATCH USE FACTORY SUPPLIED POWER WIRE(5) FOR POSITIVE AND NEGATIVE. IBC -L REQUIRES ONE 2/0 AWG PER POLE FOR UNE -UP -AND -MATCH, IBC -LH REQUIRES TWO 2/0 AWG WIRES PER POLE FOR LINE -UP -AND -MATCH. WHEN USED WITH 93PM-50, -100, -150, -200: REMOTE INSTALLATION OF MORE THAN 2 IBC -L CABINETS OR MORE THAN 1 IBC -LH CABINET WILL REQUIRE CUSTOMER SUPPLIED DC TIE BREAKER. WHEN USED WITH 93PM-400: REMOTE INSTALLATION OF MORE THAN 4 IBC -L CABINETS OR MORE THAN 2 IBC -LH CABINET WILL REQUIRE CUSTOMER SUPPLIED DC TIE BREAKER. 11. EACH BATTERY STRING OF 36 BATTERIES = 432VDC, 1 STRING PER CABINET. EACH BATTERY STRING OF 40 BATTERIES = 480VDC, 1 STRING PER CABINET. 12. SPECIFICATIONS ARE SUBJECT TO CHANGE. SIDE VIEW INTER -CABINET WIRING ACCESS (BOTH SIDES) ?CG 600 [23.6] INTER -CABINET WIRING ACCESS (BOTH SIDES) M10 THD (12X) i6 EACH SIDE 5812.3] 144.--E-. -.. 223[8.8] 388 [15.3] - 630 [24.8] 795 [31 3] 960 [37.8 1067 [42.0] 1046 [41.2] 4T r [1.9] REAR VIEW M12 THD (8X) if4• .FTSRR • 234 [9.2] 234 [9.2] 234 [9.2 BATTERY BREAKER REAR VENTILATION COVER PLATE 47 [1.9] 59[2.3] TB3 CONTROL WIRE TERMINAL TB2 ALTERNATE LOCATION FOR CONTROL WIRING TO UPS GROUND TB1 DC POWER TERMINAL FRONT VIEW, NO DOOR, 432V d • L'J■■I' .'.■■ • FRONT VIEW, NO DEADFRONT, 432V 7i I 432V TH TRAY 1 IBC -L WITH 100Ah BATTERIES 1716 kg [37831bs] IBC -L WITH 75Ah BATTERIES TRAY / • TRAY 2 IBC -LH WITH 125Ah BATTERIES 2130 kg [4696 lbs] BRAY 34 TRAY 3 Lo 1777 kg [39(8 lbs] IBC -LH WITH 161Ah BATTERIES TRAY -3 TRAY 480 V 1 [III 1` j�gsjjy�►► -Y IBC -LH WITH 103Ah BATTERIES TRAY 5 J -� 0 0 BATTERY BREAKER TB3 CONTROL WIRE TERMINAL TB2 ALTERNATE LOCATION FOR CONTROL WIRING TO UPS GROUND TBI DC POWER TERMINAL FRONT VIEW, NO DOOR, 480V • 0 • ■ mm 11 FRONT VIEW, NO DEADFRONT, 480V 11111111 11111111 WEIGHT 432V IBC -L WITH 120Ah BATTERIES 2144 kg [4727 lbs] IBC -L WITH 100Ah BATTERIES 1716 kg [37831bs] IBC -L WITH 75Ah BATTERIES 1422 kg [31341bs] Designation: IBC -LH WITH 125Ah BATTERIES 2130 kg [4696 lbs] IBC -LH WITH 95Ah BATTERIES 1803 kg [3976 lbs] IBC -LH WITH 103Ah BATTERIES 1777 kg [39(8 lbs] IBC -LH WITH 161Ah BATTERIES 2109 kg [46491bs] 480 V IBC -LH WITH 95Ah BATTERIES 1916 kg [4225 lbs] IBC -LH WITH 103Ah BATTERIES 1887 kg [4161 lbs] 98 [3.9] CENTER OF GRAVITY 432V X= 42718,8 [16.8 in] 480V X= 4108181 [16.1 in] BOTTOM VIEW 710 28.0] 151 5.9] 20 [7.9] CONDUIT LANDING PLATE METRIC I m.29..- 1 EATON CORPORATION, ELECTRICAL fferill D owa• 931H1 IBC -L, IBC LH SITE PLAN ALEAIDAAPAAESARELISIALEFINAIA0110AIMAIIIVAL SCAN HIPS ECO -080655 BBB RELEASE uYFNVWSARDISIUYEITASMasANNIMITsxousxc CNwcEMuuuLY AUTOCAD GENERATED NENAIe. P-110000114 8 7 6 5 4 3 2 H G E D C B A Page 1 of 2 Go/NEG-Alt-Date: RAZ80726X7K1-0000-7/26/2017 Job Name: Peroxychem - UPS System for Clean Room Instrumentation Item Number: Catalog Number: 9PG06D0009E2OR2 Designation: G F E D C B A 8 7 6 5 4 3 2 1 432V �+ TRAY 6 B BATTERI- ES 21-24 �+ TRAY 7 BATTER- IES 23-28 TRAY 8 BATTERI- ES 29-32 B�B TRAY 9 BATTER- IES 33-36 R R R B R B R B R B R �+ HE -TRAY 1 T— BATTERIES 1-4 J_+ TRAY 2 BATTERIES 3-8 TRAY 3 T— BATTERIES 9-12 _I_+ TRAY 4 T— BATTERIES 13-16 �+ TRAY 5 T— BATTERIES 17-20 CBI atic -1I-® AUX SHUNT 0C ..44.44, 9 T B ^ �1OA n 20A TBG A TB1 V Y DC POWER TO UPS AND NEXT IBC GND Bill y TB2 ALTERNATE CONTROL WIRING FOR TB3 PRODUCT SPECIFICATIONS DC VOLTAGE OUTPUT NOMINAL BATTERY NAMEPLATE CURRENT (216 CELLS, 2.00 V/CELL) IBC -L 432 VDC 247A IBC -LH 432 VDC 371A IBC -LH 432 VDC 495A IBC -LH 480 VDC 334A IBC -LH 480 VDC 445A TOP VIEW REAR EXHAUST CONFIGURATION REAR VIEW CUSTOMER SUPPLIED WIRING, IBC -L TO 93PM SERIES UPS RAZ80726X7K1-0000-7/26/2017 ACCEPTED WIRE RANGE TORQUE RATING Nm [LB -IN] RECOMMENDED MINIMUM WIRE SIZE FOR 75 deg C COPPER STRANDED WIRE BATTERY WIRES 6 AWG - 250 MCM 31 [275] 3/0 AWG (2X PER POLE) GROUND WIRES 14 AWG - 1/0 5.1 [45] 4 AWG CONTROL WIRES 12-24 AWG 0.7 [6] 18 AWG TOP VENTILATION COVER PLATE REAR VENTILATION 480V B R B R B R B R B R B B TRAY 6 BATTERIES 21-24 TRAY 7 BATTER- IES 25-28 TRAY 8 T— BATTERIES 29-32 —_ TRAY 9 T— BATTERIES 33-36 _I_+ TRAY 10 T— BATTERIES 37-40 R R R R R R =TRAY 1 BATTERI- ES 1-4 TB3 OPTIONAL I TRAY 2 BATTERIES 5-8 —TRAY 3 BATTER- IES 9-12 =TRAY 4 BATTER- IES 13-16 =TRAY 5 BATTERI- ES 17-20 CB OPTIONAL VNanR «, HHS 4� AUX SHUNT 60C ..6646, 60C (_) BOB • 44, (+) 20A TBG TO UPS AND NEXT IBC GND A TB1 DC POWER FIFA 7V TB2 ALTERNATE CONTROL WIRING FOR TB3 CUSTOMER SUPPLIED WIRING, IBC -LH TO 93PM SERIES UPS RAZ80726X7K1-0000-7/26/2017 ACCEPTED WIRE RANGE TORQUE RATING Nm [LB -IN] RECOMMENDED MINIMUM WIRE SIZE FOR 75 deg C COPPER STRANDED WIRE BATTERY WIRES 6 AWG - 350 MCM 31 [275] 300 MCM (2X PER POLE) GROUND WIRES 14 AWG - 1/0 5.1 [45] 1 AWG CONTROL WIRES 12-24 AWG 0.7 [6] 18 AWG CONTROL WIRING TB3-1' TO UPS SHUNT + TB3-2' TO UPS SHUNT - TB3-4 TO UPS BATT DETECT TB3-5 TO NEXT IBC -L TB3-4" TB3-6 TO NEXT IBC -L TB3-1 TB3-7 TO NEXT IBC -L TB3-2 IN FIRST IBC -L, UPS MAY WIRE TO TB3 OR TB2 " IN FINAL IBC -L, TB3-5 RETURNS BACK TO UPS BATT DETECT COMMON METRIC 1 —SS,. EATON CORPORATION, ELECTRICAL Ifer•II■ D xx.xna 93PM IBC -L, IBC -LH SITE ELAN ECO-OBOSSS SUR RELEASE 011-1131MSE 5PB:IrED 101.1,1,14. ON .1.90. ARE AMU, 11, DECiABLB 6,665 40066416, 60665 6049 06:6035 400666005 9446B NTS BO BOT666. AUTOCAD GENERATED HRH.... P-11000011' 1. 015 SHEET 2 OF 2 8 7 6 5 4 3 2 1 H G E D C B A Page 2 of 2 Go/NEG-Alt-Date: RAZ80726X7K1-0000-7/26/2017 Job Name: Peroxychem — UPS System for Clean Room Instrumentation Item Number: Catalog Number: 9PG06D0009E2OR2 Designation: